ON-SITE WASTEWATER INSPECTION REPORT
Permit Number: OSP201160 PID Number: 015-362-14
Dwelling: 0 Single Family (SF) ❑ with ADU ❑ Duplex (D) ❑ Two Single Family Project: ❑ New X Upgrade
Name
Ricky and Carolyn Byrd
A 0RPTION FIELD
❑ D Trench ❑ Wide Trench ❑ Bed ❑ Mound
Site Address
9400 Maintree Drive
❑ Other
Phone
Number of Bedrooms
Soil RatingTotal
depth from original grade
4
PD/SF
Ft.
LEGAL DESCRIPTION
Depth to pipe invert from origins ad
st,
Gravel depth beneath pipe
Ft.
Subdivision Block Lot
ROCKHILL 1 6
Fill added above original gradevel
Ft.
length
Ft.
Township Range Section
Gravel width
Ft.
Beds: Number of Lines
Di nce between lines
Ft.
SEPARATION DISTANCES
To
Septic
Absorption
Lift Station
Holding
Sewer
Total absorption area
Number of trenches
Dist. betwee trenches
From
Tank
Field
Tank
Line
Ftz
Ft.
Well
>100'
NA
NA
I NA
TANK 0 Septic ❑ S.T.E.P. ❑ Holding ❑ Other
Manufacturer
Greer
Capacity
1250 Gal.
Surface Water
>100'
NA
NA
NA
Material
Number of compartments
Lot Line
>10
NA
NA
NA
NA
plastic
2
Foundation
> 10
NA
NA
NA
LI T STATION
Manufactu �
Capacity
Remarks
Gal.
Alarm location
Elie`ctri I installed by
PIPE MATERIAL House to tank D3034 drainfield Tank to
D3034
Installer
Territory North
Drainfield CO/MT D3034
Inspector Brandon Jones
BENCH MARK (Assumed elevation) 100 ft
Inspeection 6/27/2020
1'' 6/26/2020
Location and description
ction 2�a
3`d 6/30/2Cb 411
cross bar on NG gas meter
ON-SITE WATER AND WASTEWATER SECTION APPROVAL
Engineer's Stamp
Conditional Approval: Date
'°°°°°"• '.•••�
�� 6=•.
Septic System
-7,
Appro ti,.. i� Date—w
y��/
Note: this approval does not include well permit requirements.
kmuv UOlUL! I O)
\ NEIGHBORING SEPTIC
THERE ARE NO STEEP SLOPES IS > 10' FROM
\WITHIN 50' OF THE PROPOSED / PROPERTY LINE k
TANK.
100'
NEIGHBORING SEPTIC
\IS > 10' FROM
PROPERTY LINE
0\
4 BR
/ HOME /
/ B / BM
NEIGHBORING SEPTIC
IS > 10' FROM
PROPERTY LINE \ c SWING TIES ON PAGE 2 /
NEIGHBORING WELL IS > \ /
100' FROM PROPERTY LINE NEW 1250 GAL SEPTIC TANK
Cof 8 DOUBLE
CLEANOUTS EXISTING 34' x 36" x 60"
SCOPE OF WORKFLAT SLOPE � EFFECTIVE DEPTH TRENCH I
L ��^
1. EXISTING SEPTIC TANK WAS REMOVED. — — _ —
2. NEW 1,250 GALLON SEPTIC TANK WAS — -iS MT
PLACED AND TIED INTO EXISTING
ABSORPTION SYSTEM. THE TANK WAS
PROVIDED WITH MINIMUM 20" 0 MANWAY Lot 7——
RISER SERVING THE FIRST COMPARTMENT. - — — — —
3. ALL CONSTRUCTION WAS IN ACCORDANCE NEIGHBORING SEPTIC NEIGHBORING WELL IS >
WITH ALL REQUIREMENTS SPECIFIED IN IS - 20' FROM 100' FROM PROPERTY LINE J
ANCHORAGE MUNICIPAL CODE CHAPTERS PROPERTY LINE
15.55 AND 15.65. BM IS CROSS BAR ON TOP OF
GAS METER, ASSUMED 100'
Septic As Built Drowings Prepored for
RICKY AND CAROLYN BYRD ®+� OF
9400 Maintree Dr Anchorage, AI ���P�
g Alaska 99507
r 49TH ��
AF
ROCKHILL BLOCK 1 LOT 6 �......•......r T....... ...................�
OSP201160
EKLUTNA ENGINEERING LLC �. • RTIS
.................. W
DATE: 6/30/2020 ��, �. CURTIS TOwNSEND: �
19162 MOUNTAIN ROAD DRAWN: CLT ®0 s •. No. CE 11904
CHUGIAK, ALASKA 99567 %3t
SCALE: 1" = 40' ®®�® "�•••••!••...••��,®�®�
(907) 355-9820
PID: 015-362-14 SHEET 1 OF 2
LEGEND
Q
FOUND REBAR
LOT 5
i
S;
SEPTIC VENTWEH
PLAT 79-37
CABLE PEDESTAL���
LE
ELECTRIC PEDESTAL
TELEPHONE L 0 T 4
I
PEDESTAL
r
LEi
ELECTRIC
TRANSFORMER
LIGHT POLE
98.04
_
ASPHALT
DRIVEWAY
ROCKH/LL
4'ss2� w SUBDI VISION
�0y E LOT 6
BLOCK 1
i66Q6, �S PLAT 80-9
LOT 8
% 10' UNDERGROUND T & E EASEMENT
NOTES: II N 87'46'36" E 159.22'— — —
1. DIMENSIONS ARE RECORD PER PLAT 80-9. L� -- — — — — — — — — —
2. UTILITIES OTHER THAN THOSE SHOWN MAY EXIST. LOT 7
3. THIS SURVEY DOES NOT CONSTITUTE A BOUNDARY SURVEY AND IS SUBJECT TO ANY INACCURACIES THAT A
SUBSEQUENT BOUNDARY SURVEY MAY DISCLOSE. UNDER NO CIRCUMSTANCES SHOULD ANY DATA SHOWN BE
USED TO ESTABLISH ANY FENCE, STRUCTURE OR ANY OTHER IMPROVEMENTS.
4
0
ALL VISIBLE ABOVE GROUND FEATURES OF THE EXISTING SEPTIC SYSTEM WERE LOCATED AT THE TIME OF
SURVEY AND ARE SHOWN HEREON.
o
law;
. • l ASBUILT — NO CORNERS SET THIS DATE
co •,"� I HEREBY CERTIFY THAT I HAVE PERFORMED
Thi A SURVEY OF
/�j • �• . �/�~� LOT 6, BLOCK 1, ROCKHILL SUBDIVISION,
• • f• • V • • • • . • • • PLAT NO. 80-9, ANCHORAGE RECORDING
r Dayna M. Rumfelt ® DISTRICT, ALASKA,
�� �`c • • • No. LS Q133322
��4p•Y
AND THAT
ET DEPICTED d.1HEREON EXIST AS SHOWN NRCATON TO
OF�gs 0NAL� THE PROPERTY LINES. EASEMENTS OF
RECORD OTHER THAN THOSE SHOWN ON
RECORDED PLAT No. 80-9 ARE NOT SHOWN
L HEREN UNLESS ONOTE. N D /A\Y
E R DATE:6/30/220 FB:20-2 O
US SURVEY FEET SURVEY & MAPPING GRID: 2438 DRAWN: DMR
2890 S. BARNYARD CIR., WASILLA, AK 99654
DAYNAO.AVENDERSURVEY.COM (907)301-5177 SCALE: 1" = 50' FILE: 20-021AB
Municipality of Anchorage
P.O. Box 196650 a 4700 Elmore Road
Anchorage, Alaska 99519-6650 ® (907) 343-7904 ® Fax (907) 343-7997
http://www.muni.org/Onsite
Development Services Division
On -Site Water and Wastewater Program
x x x x VARIANCE/WAIVER REVIEW x x x x
Waiver#: OSV201034 COSA#: Permit#:OSP201160
PID#: 015-362-14
Legal Description: ROCKHILL BLK 1 LT 6
Engineer:
Your request for a waiver of the required 10 feet horizontal separation from the absorption field to
the property line has been approved. The approved separation distance is 8.0 feet.
This waiver approval applies to the existing absorption field only. Any fixture upgrade to the on-
site wastewater disposal system will require all separation distances be met or another approval
from this department.
0 v v v v v v v v v v IN v v v v v v v v v v v v v v v v v v v v v v v v v v v v v v v v v v v v v v v v v v v v v e v v v v v v v v v v v v v v v v v v v I
Waiver is Granted: X Waiver is not Granted:
Date: 2(1 Approved by:
Name of Revie
■■ v v v v v v v v v v v v v v v v v v v is v v v t v v v v v v v v C v e ■.■ ■ v v v v v v v v v v v v v v v v v■ ■ v v v v v v v v v v v v v v v v v
**** VARIAN C EMAIVE R REVIEW ****
ENSTAR ENSTAR Natural Uas Company
A Division of Qg SL .MCOENERGYARAMMU -
30p0 Spenard Road
P.4. Box; 19LI288
Anchorigc, AK 99519-0288
(901) 277-5171
12/10/01
Jack White, Prudential
3201 C Street, Suite 200 Re: Letter of Non -objection
c/o Olga Grid A2438
Anchorage, Alaska 99507
To whom it may concern:
ENSTAR Natural Gas Company has no objection to a septic vent encroachment, into
the Main Tree Drive right of way situated on the south property boundary for the
subject property know as Lot 6, Block 1, Rock Hill Subdivision.
Acceptance and use of this letter of non -objection by yourself, your heirs, your
assigns, or your successors, will constitute agreement to the following stipulations
ENSTAR will be held harmless, now and forever for any damages or injury to
any person or property as a result of this encroachment.
Any ENSTAR facility damaged or destroyed, as a result of this encroachment
will be repaired at no cost to ENSTAR.
Any costs incurred by ENSTAR for special construction necessitated by this
encroachment will be borne by the property owner.
All applicable safety code regulations will be observed and maintained.
This letter of non -objection will in no way preclude ENSTAR from full use and
enjoyment of its rights within any portion of its right-of-way.
Sincerely,
M. Manuel Lopez, r., Rig tofVAent
ENSTAR Natural G _ Cmm�arn�
cc: File
GaLaska
CONIHUNIcaYKAN5.
alaskacommunicati ons.com
June 22,2020
Ricky & Carolyn Byrd
9400 Main Tree Dr
Anchorage, Alaska 99507
Alaska Communications has no objections to the existing septic vent encroaching into the 10' Telecommunications &
Electric Easement located along the southern boundary of block 1, lot 6, Rockhill Subdivision, otherwise known as
9400 Main Tree Dr, Anchorage, Alaska as depicted on the drawing provided by Curtis Townsend.
Alaska Communications currently utilizes this easement and has no objections to the encroachment Alaska
Communications hereby issues this letter with stipulations to allow the encroachments of the above mentioned into the
easement-
Acceptance,
asementAcceptance, (your signature below), and use of this letter of non -objection by yourself, your heirs, your assigns, or your
successors, will constitute agreement to the following stipulations:
1. Alaska Communications will be held harmless, now and forever, for any damages or injury to any
person or property as a result of this encroachment.
2. Any Alaska Communications facility damaged or destroyed as a result of this encroachment will be
repaired at no cost to Alaska Communications.
3. Any costs incurred by Alaska Communications for special construction necessitated by this
encroachment will be borne by the property owner.
4. All applicable safety code regulations will be observed and maintained.
5. This letter of non -objection will in no way preclude Alaska Communications from full use and
enjoyment of its rights within any portion of this easement
6. Alaska Communications is under no obligation to restore any structure damaged as a result of Alaska
Communications full use and enjoyment of its rights within any portion of easements or right-of-ways.
Please sign both copies, retain one copy for your use and return the other to Alaska Communications.
Sincerely,
Austin King,
Network Engineer Ii, Outside Plant
Alaska Communications
Outside Plant Engineering, MS#14
600 Telephone Ave.
Anchorage, AK 99503
Grid SW2436 OWC
DATE:
June 29, 2020
Curtis Townsend, PE
Eklutna Engineering, LLC.
To whom it may concern,
Subject to your agreement to indemnify the company as set forth below, GCI
Communication Corp has no objection to the existing septic vent encroaching
into the T&E easement of Lot 6, Block 1, Rockhill Subdivision, also known as
9400 Main Tree Drive, city grid 2438, GCI WO#20-0006-21.
This letter of non-objection in no way precludes GCI Communication Corp from
full use and enjoyment of any rights it may have within any portion of the utility
easement and or the right-of-way, including unlimited access for servicing its
facilities. Also, any additional and extraordinary costs incurred during any future
required construction, repair or reconstruction of GCI’s facilities to accommodate
any or all the encroachments shall be paid by the property owner.
By signing below, you agree to indemnify and hold GCI Communication Corp
harmless, now and forever, for any damage, costs, expense (including
reasonable attorney's fees), liabilities and injury to any person or property
occurring as a result of the encroachment.
Please indicate your acceptance by signing and returning this letter to me at the
address below.
Sincerely, ______________________________
Signature
______________________________
Date
Markus Kofoid
Manager Sr. Field Services Central Region
GCI Communication Corp
5151 Fairbanks St.
Anchorage, AK 99503
907-868-6168 Office
907-868-8580 Fax
DocuSign Envelope ID: 3D26F8AF-6175-41E1-9D45-F0D9F00ABCFC
2001-085096-0
�� Recording Dist: 301 - Anchorage
SK
I IIIVII1111111lll!IIIIIII@1111IIIIIIIIII111111III'9111111'llll11
ENCROACHMENT PERMIT 1203-14B CC'
G-2438
EN01080
015-362-14
This permit is between Chugach Electric Association, Inc., an Alaska non-profit electric
cooperative, (herein "Chugach"), whose address is P. O. Box 196300, Anchorage, Alaska 99519-
6300 and John Watsjold (herein "Permittee") whose address is 9400 Main Tree Drove, Anchorage,
Alaska 99516.
1. Easement. Chugach is the grantee or user of an easement for the construction and
maintenance of electrical facilities, as follows:
Described in that certain written instrument recorded on the 12th day of December 1955 at
Volume 126, Page 53 of the records of the Anchorage Recording District, Seward
Meridian, Alaska,
Described in that certain written instrument recorded on the 20th day of April 1982 at Book
722, Page 339 of the records of the Anchorage Recording District, Seward Meridian,
Alaska,
Dedicated by the plat of the subdivision known as Rockhill Subdivision, according to Plat
Number 80-009, recorded on the 13t' day of February 1980, on file in the office of the
District Recorder, Anchorage Recording District, Seward Meridian, Alaska,
(herein "Easement") which pertains to the following described real property:
The South Ten Feet (S 10') of Lot 6, Block 1, Rockhill Subdivision, according to Plat
Number 80-009, recorded on the IP day of February 1980, on file in the office of the
District Recorder, Anchorage Recording District, Seward Meridian, Alaska.
Permittee acknowledges the validity of the Easement. Permittee warrants and represents that
Permittee is the owner of the fee simple interest in the land subject to the Easement and the
following described real property to which the Easement is adjacent:
Encroachment Permit - Page ,1 of 4
Lot 6, Block 1, Rockhill Subdivision, according to Plat Number 80-009, recorded on the
13t` day of February 1980, on file in the office of the District Recorder, Anchorage
Recording District, Seward Meridian, Alaska,
(herein "Parcel')
2. Encroachment. Permittee proposes to continue the existence of the following
improvement(s) on or within the real property subject to said Easement:
A septic system vent pipe within the said Easement approximately 8 feet north of the south
property line,
(herein "Encroachment")
3. ` Permit. Chugach hereby authorizes Permittee to continue the existence of the
Encroachment in its proposed location subject to the covenants set forth in this permit.
4. Indemnification. Permittee shall indemnify and hold Chugach harmless from any
claims for personal injury, property damage or other loss arising in any way from the continuation of
the Encroachment.
5. No Expansion or Increase. Permittee shall not in any way expand or increase the
extent to which the Encroachment occupies any of the real property encumbered by the Easement
without the prior written consent of Chugach. Chugach has no obligation to provide such consent.
6. No Interest in Real Estate Acquired. Permittee hereby acknowledges that the
Encroachment and any additions thereto, even if in violation of this permit, has not and shall not in
the future give rise to any interest or estate in the real property subject to the Easement or any other
real property. Without in any way limiting .the foregoing, Permittee acknowledges that the
Encroachment is not adverse to any interest of Chugach and its continuation is entirely with the
permission of Chugach for purposes of the common law doctrine of adverse possession. This permit
creates no interest in the real property subject to the easement.
7. Modification of Utility Facilities. If the electric utility facilities located within the
Easement are upgraded, added to, replaced or reconstructed, Permittee shall pay that portion of
Chugach's total costs for such modification which is reasonably attributable to accommodating or
preserving the Encroachment. If such payment is not made within thirty (30) days of written demand
for same, Chugach may terminate this permit in accordance with paragraph 9, below.
8. Covenants Running with the Land. The obligations of the Permittee arising from this permit
shall be covenants running with the land which shall burden the Parcel and the Permittee's interest in
the land subject to the Easement and shall benefit the Easement.
Encroachment Permit - Page 2 of 4
V I I I III I fN1111111 1I-�
o4
2001-085099-0
9. Termination. Chugach may terminate this permit after the giving of thirty (30) days
written notice of such termination if -
a. The Encroachment is enlarged, increased or extended within the real property
affected by the Easement.
b. ' The Encroachment is damaged by any means to an extent of more than thirty percent
(30%) of its replacement cost at the time of destruction.
C. Permittee fails to make the payment described in paragraph 7, above.
I
10. Term. This permit shall, if not sooner terminated by Chugach, expire forty (40) years
from the date hereof.
11. Entire Agreement. This written permit constitutes the entire agreement between the
parties with respect to the subject matter hereof and supersedes all other prior or contemporaneous
agreements, oral or written, between the parties. No modifications, amendments, deletions, additions
or alterations of the permit shall be effective unless in writing and signed by all of the parties hereto.
CHUGACH ELECTRIC
ASSOCIATION, INC.
By:
L hibert, Executive Manager
T&D Network Services
Date:
PERMITTEE
By: C� l
//John Watsjold
Date:_ _ 0 - /�L - D 1
Encroachment Permit - Page 3 of 4
,- �����II����IIIII�{IIllliilillll
3 of 4
2001-086096-0
STATE OF ALASKA )
) ss:
THIRD JUDICIAL DISTRICT )
The foregoing instrument was acknowledged before me this day of
2001, by S 1 C
Notary Public i d for the State of Alaska
My commission expires: U 6)
'V'j!°�."r'
STATE OF ALASKA )' ' �•= `' ;
THIRD JUDICIAL DISTRICT ) fz'T= ''1p
`_'
e foregoing instrument was acknowledged before me this day of
2001, by Lee Thibert, Executive Manager, Transmission and
Distribution Network Services of Chugach Electric Association, Inc., an Alaska corporation, on
behalf of the corporation.
Notary Public in and for the State of Alaskg'�.', 4z
�r • _
My commission expires:
S7 Is
of ._,�. � .. •••'� "'tip
AFTER RECORDING RETURN = 0::
Chugach Electric Association, Inc.
P.O. Box 196300
Anchorage, Alaska 99519-6300
Encroachment Permit - Page 4 of 4
�iII�IIIIIIVIVIIiN�I �
20-01-086096-0
MUNICIPALITY OF ANCHORAGE
On -Site Water & Wastewater Program
PO Box 196650 4700 Elmore Road
Anchorage, Alaska 99519-6650 Phone: (907) 343-7904 Fax: (907) 343-7997
http:llwww.muni.org/onsite
On -Site Wastewater Disposal System Permit
Permit Number: OSP201160
Work Type: SepticTank Upgrade
Tax Code Number: 01536214000
Site Legal Address: ROCKHILL BLK 1 LT 6 G:2438
Site Mailing Address: 9400 MAIN TREE DR, Anchorage
Owner: BYRD RICKY L & CAROLYN K
Design Engineer: EKLUTNA ENGINEERING, LLC"
This permit is for the construction of:
❑ Disposal Field Q Septic Tank ❑ Holding Tank ❑ Privy
Effective Date:
Expiration Date:
t„cnr
ri ^
Ucpartancnt
Lot Size in Sq Ft:
Total Bedrooms:
6/17/2020
6117/2021
46660
❑ Private Well ❑ Water Storage
All construction shall be in accordance with.
1. The attached approved design.
2. All requirements specified in Anchorage Municipal code Chapters 15.55 and 15.65 and the State of Alaska
Wastewater Disposal Regulations (18AAC72) and Drinking Water Regulations (18AAC80)
3. The wastewater code requires inspections during the installation. The engineer shall notify the Development
Services Department per AMC 15.65. Provide notification by calling (907) 343-7904 (2417).
4. From October 15 to April 15, a subsurface soil absorption system under construction during freezing weather
shall be either:
a. Opened and Closed on the same day, or
b. Covered, sealed, and heated to prevent freezing
Received B
Issued By:
f
Y= Date: r Z U
`
Date: 1li
4
MUNICIPALITY OF ANCHORAGE
0 Alle
Development Services Department '� J� Phone: 907-343-7904
On -Site Water & Wastewater Section Fax: 907-343-7997
ON-SITE SEPTICIWELL PERMIT APPLICATION
Parcel I.D. 015-362-14
Property owner(s) BYRD RICKY & CAROLYN Day phone
Mailing address 9400 Maintree Drive Anchorage AK 99507
Site address 9400 Maintree Drive Anchorage AK 99507
Legal description (Sub'd., Block & Lot) ROCKHILL
Legal description (Township, Range & Section)
Lot Size 46,660 Sq. Ft. Number of Bedrooms 4
BLK 1 LT 6
APPLICATION IS FOR:
APPLICATION IS AN:
TYPE OF DWELLING:
(® all that apply)
Absorption Field
❑
Initial ❑
Single arially (aF) ❑
/wo ADf:J
Septic Tank
Q
Upgrade Q
()
(D) ❑
Holding Tank
❑
Renewal FJDuplex
Multiple Dwellings ❑
Privy
❑
(SF and/or D)
Private Well
❑
Water Storage
❑
THIS APPLICATION INCLUDES A WAIVER REQUEST FOR:
Distance:
I certify that the above 1or. ation is correct. I further certify that this is in accordance with
applicable Municipal Code,
G
Signature of property owner or authorized .agent)
Permit/Rush Fees: 2A5- -- Waiver Fees:
Date of Payment: la ll 6 f oZU vZb Date of Payment:
Receipt Number: aq(QReceipt Number:
Permit No. (3 S %dab! 1100 Waiver No.
GADevelopment ServicesOuilding Safetffln Site Water and WastewaterWormsOient ForrnsTermit Application.doc
COVID-19
2570 DISCOUNT APPLIED
Municipality of Anchorage
On-site Water and Wastewater
REVIEWED FOR CODE COMPLIANCE
OSP201160, Deb Wockenfuss, 06/17/20
Municipality of Anchorage
On-site Water and Wastewater
REVIEWED FOR CODE COMPLIANCE
OSP201160, Deb Wockenfuss, 06/17/20
LEGEND
Q
FOUND REBAR
i
LOT 5 /
1 S;
SEPTIC VENT
PLAT 79-37
cw
WELL
i / I
CABLE PEDESTAL
ELECTRIC PEDESTAL
/
PGF /
E
LOT 4
\
PEDESTAL
F ,
ELECTRIC/
Nb
/E-1
L
TRANSFORMER
t
LIGHT POLE/
/ / /
/
184•
_W
140 /l ASPHALT
6' CHAINLINK FENCE / 4,4'
DRIVEWAY
N Ss�,
�6
LOT 8 6�6�
ROCKH/LL
SUBDI VISION
LOT 6
BLOCK 1
PLAT 80-9
10' UNDERGROUND T & E EASEMENT
NOTES: II N 87'46'36" E 159.22'_
1. DIMENSIONS ARE RECORD PER PLAT 80-9. L� — — — — — — — — —
2. UTILITIES OTHER THAN THOSE SHOWN MAY EXIST.
LOT 7
� LO
3. THIS SURVEY DOES NOT CONSTITUTE A BOUNDARY SURVEY AND IS SUBJECT TO ANY INACCURACIES THAT A
SUBSEQUENT BOUNDARY SURVEY MAY DISCLOSE. UNDER NO CIRCUMSTANCES SHOULD ANY DATA SHOWN BE
USED TO ESTABLISH ANY FENCE, STRUCTURE OR ANY OTHER IMPROVEMENTS.
4.
ALL VISIBLE ABOVE GROUND FEATURES OF THE EXISTING SEPTIC SYSTEM WERE LOCATED AT THE TIME OF
SURVEY AND ARE SHOWN HEREON. �G`_��\\\
0
AIW A�gSlll ASBUILT - NO CORNERS SET THIS DATE
wG,'• I HEREBY CERTIFY THAT I HAVE PERFORMED
•*Q49T ••* A SURVEY OF
• • •,n •Il .ILOT 6, BLOCK 1, ROCKHILL SUBDIVISION,
/ �15i' V J ..... � PLAT NO. 80-9, ANCHORAGE RECORDING
Dayna M. Rumfelt / DISTRICT, ALASKA,
�+�`�sl• No�S13322 ..•���/ AND THAT THE IMPROVEMENTS AS DEPICTED
��l``9FpPR'p!l•��QS�,� HEREON EXIST AS SHOWN IN RELATION TO
OFESSIoNNOY THE PROPERTY LINES. EASEMENTS OF
RECORD OTHER THAN THOSE SHOWN ON
RECORDED PLAT No. 80-9 ARE NOT SHOWN
VDHEREN UNLESS" /A
. NN D F � DATE:6/16/2020 THERWIBE 200 -2
SCALE 1 = SURVEY & MAPPING GRID: 2438 DRAWN: DMR
US SURVEY FEET
2890 S. BARNYARD CIR., WASILLA, AK 99654
DAYNAGAVENDERSURVEY.COM (907)301-5177 1 SCALE: 1" = 50' 1 FILE: 20-021AB
MUNICIPALITY OF ANCHORAGE
DEPARTMENT OF HEALTH & ENVIRONMENTAL PROTECTION
ENVIRONMENTAL ENGINEERING DIVISION
825 L Street- Anchorage, Alaska 99501 Telephone 264-4720
ON-SITE SEWAGE DISPOSAL SYSTEM AND/OR WELL INSPECTION REPORT
MAILINGADDRESS~w? / ~_~~~
[] UPGRADE
LOCATIOI'
Wel I
DISTANCE TO: ~ /'
Man ufacturer~.~l~ ~
Liq. ( Inside length
DISTANCE TO: Dwe ng
A~soFc~d' ~rea
Dwelling /
Width
NO. O~/E D ROOMS
PERM, NO.7106--6
Liqui~epth
Foundation,
Material
IF HOMEMADE:
Well PERMIT NO.
Manufacturer Liquid capacity in gallons
DISTANCE TO:
inches
We,: /dO /
No. of line~l~/ Lengt h_o, fr~j./_/each Iline
Top of tile to finish grade
Total leng~J;l, of lin§s
Material beneat~ tile
PERM'T NZ/O ;
Length Width Depth
Type of crib Crib diameter Crib depth Total effective absorption area
Well Building foundation Nearest lot line
DISTANCE TO:
Depth Driller Distance to lot line PERMIT NO.
Building foundation Sewer line Septic tank Absorption area(s)
DISTANCE TO:
i Dista nce~e~e~ Ii nes
Total effective absorption area
PERMIT NO.
OTHER
PIP E MAT ER IA~**~_./~ ~.¢
SOl L TEST RATI NG~_~
INSTALLER ~.~~ ~ ¢
REMARKS
APPROVED ~ / ~ DATE LEGAL
U
,L
· ; l.,-I [.~ L L FI I"-,I
F'ERMIT NO. ( 810567 )
825 "L" STREET, RNCHORRGE, RK. 9950:L
;~:64-4720
3:795 W INTER. SET
RFFL I_.HNT JOHN WFITSJOLD
LOCRTION MRIN TREE [:,RIVE
LE 3RL
L 6 8"I.L. ROCKH ILL _,~ D
LOT S I ~.E b40k~-,,:c'F. ..... I IAI~'F FEET
' '- ']"" '--' "- IS '
TYPE GF SOIL HB:,_F. FTION _,~:,TEM : TREN..H
MH,.,IMLIM NLME, EE OF E:EDROOM':; = 4-
..-,LIL RRTING (SQ FT,.'BR,, ........
THE REQUIRED :,I~.E UF THE. :,UIL HtE,:,OR UN . .:, T :, I EM I~. ~
"~ L /
[. EF TFI--. 13: L,E~,]TH==-' ,3E_"R%."EL [)EF TH=~
'THE LENGTH [:, I MENS I ON IS THE LENgtH (IN FEET::, OF THE TRENCH OF: DR~INFIEL[),
THE DEPTH OF B TRENCH OR PIT IS THE DISTflNCE BETWEEN THE SURFACE OF THE
GROUND ~ND THE BOTTOM OF THE EXCBVBTION (IN FEET).
THERE IS NO SET WIDTH FOR TRENCHES.
THE GRBVEL DEPTH IS THE MINIMUM DEPTH OF GRBYEL BETWEEN THE OUTFBL. L PIPE
FIND THE BOTTOM OF THE EXCBMBTION (IN FEET)·
RE[:. :.EFT I C: l'l~-~::,{ S I. ZE= 1;~_"5E-~ ...... --
FERMIT HFFLI~HNT HH::, THE RESPONSIBIL. IT"r' TO INFCRM THIS DEPRRTMENT DIJRING THE
· '- ...... I '- -' I-I ~ ' I] '" ' ~'
tN.:,]HLLHTILN IN:,PEL. TI.N:, GF RNY WELLS RDJRCENT TO THIS FR.FERT'r RND THE
NLMBER OF RE:,IE. ENE. E:, THFIT THE WELL WILL SERVE.
BFICKFILLII'.,IG OF RNY --,~_TEM F.IITHOUT FINRL INSPEC"I'InI'-,I FIND., FIPPRO',,,'FIL BY THIS
DEF'FIRTMENT WILL BE SUBJECT TO PROSEE_TIEN.
MINIMUM DISTRNCE BETWEEN Ft WELL RND FINY ON-SITE SEWFIGE DISPOSRL SYSTEM IS
±00 FEET FOR R PRIVFITE WELL OR ~50 TO 200 FEET FROM R PUBLIC WELL DEPENDING
UPON THE TYPE OF PUBLIC WELL.
MINIMUM DISTRNCE FROM R PRIVRTE WELL TO R PRIVRTE SEWER LINE IS 25 FEET FIND
TO R COMMUNITY SEWER LINE IS 75 FEET.
WELL LOGS RRE REQUIRED RND MUST BE RETURNED TO THE DEPRRTMENT WITHIN 30 DRYS
OF THE WELL COMPLETION.
OTHER REQUIREMENTS; MRY RPPLY. SPECIFICFITIONS RND CONSTRUCTION DIFIGRRMS RRE
RVRILRBLE TO INSURE PROPER INSTRLLRTION.
F, ERt-1 3[ 'T F.---.F I F~'E_, [)EC:Et,'IE:EF.' Ltl..
I CERTIFY THFIT
1: I RM FRMILtRR WITH THE REQUIREMENTS FOR ON-SITE SEWERS FIND WELLS FIS SET·
FORTH BY THE MUNICIPALITY OF RNC:HORRGE. r
2: I WILL INSTRLL THE SYSTEM IN RCCORDRNCE WITH THE CODES.
3:: I UNDERSTRND THFIT THE ON-SITE SEWER SYSTEM MRY REQUIRE ENLRRGEMENT IF ]"HE
RESI[:'ENCE IS REMODELED TO INCLUDE MORE THFIN 4 BEDROOMS.
S I GNED: ...............................................
~FFLIL. HN[ JOHN WRTSJOLD
MUNICIPALITY OF ANCHORAGE
DEPARTMENT OF HEALTH AND ENVIRONMENTAL PROTECTION
825 L. Street, Anchorage, Alaska 99501 264-4720
SOILS LOG - PERCOLATION TEST
[~'SOILS LOG
[] PERCOLATION
TEST
PERFORMED FOR:
DATE PERFORMED: (0'-- ~"-- ~ J
LEGAL DESCRIPTION: ~_ Cb"'[-[.~ ~t~-'~ ~
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15-
16-
17
18
19
2O
COMMENTS
SITE PLAN
72-008
SLOPE
WAS GROUND WATER
ENCOUNTERED?
IF YES, AT WHAT
DEPTH?
Reading Date Gross Net Depth to Net
Time Time Water Drop
PERCOLATION RATE
TEST RUN BETWEEN
FT AND
(minutes/inch)
__ FT
DATE:
MUNICIPALITY OFNCS!
Development Services Department:-' Phone: 907-343-7904
On -Site Water & Wastewater Section Fax: 907-343-7997
Parcel 1. D. 015-362-14
1
Certificate of On -Site Systems Approval
GENERAL INFORMATION
Complete legal description Rockhill B1 L6
Location (site address) 9400 Main Tree Dr
Current property owner(s) Ricky & Carolyn Byrd Day phone 907.770.6067
Mailing address 9400 Main Tree Dr. Anchorage, AK 99507
Real estate agent Bob Bolding
Expiration Date: j©— b Z 0 Zy
Anchorage, AK 99507
2. TYPE OF DWELLING:
0 Single Family
❑ Duplex
❑ Multiple Dwellings (Single Family and/or Duplex)
3. NUMBER OF BEDROOMS: 4
Day phone 907.230.0700
4. TYPE OF WATER SUPPLY:
TYPE OF WASTEWATER DISPOSAL:
Private Well
x❑
Private Septicx❑
Water Storage
❑
Holding Tank
❑
Community Well
❑
Community
❑
Public Water System
❑
Public Sewer
❑
Waiver request for:
Distance:
Received by: Date:
COSA to be released to the engineer, unless otherwise requested by the engineer.
COSA Fee $ 5X / g 1 a. 5 o
01
Date of Payment Aj'V O
Receipt Number 0003 ie
COSA # 0 C.20 , 0 I l
Waiver Fee $
Date of Payment
Receipt Number
Waiver #
5. STATEMENT OF INSPECTION BY ENGINEER
As certified by my seal affixed hereto and as of the validation date shown below, I verify that my investigation, based
on procedures outlined in the Certificate of On -Site Systems Approval Guidelines for this application, shows that the
on-site water supply and/or wastewater disposal system is (are) safe, functional and adequate for the number of
bedrooms and type of structure indicated herein. I further verify that based on the information obtained from the
Municipality of Anchorage files and from my investigation and inspection, the on-site water supply and/or wastewater
disposal system is (are) in compliance with all applicable Municipal and State codes, ordinances, and regulations in
effect at the time of installation. I acknowledge that On -Site staff may visit the site to verify the information submitted.
Name of Firm Eklutna Engineering, LLC. Phone (907) 355-9820
Address 19162 Mountain Rd. Chugiak, AK 99567
Engineer's Printed Name Curtis Townsend Date 5/28/2020
6. DSD SIGNATURE
KSystem #1 Approved for q bedrooms
System #2 Approved for
Disapproved
Conditional approval for
bedrooms
low
P4s�-��
g�• gym• d � .
Date
P�hsr No.
PRO '
bedrooms, with the following stipulations:
WP,TER AND
VVASTLyN%T o1
Original Certificate Date: `2� 6 Z 0 Zy
The Municipality of Anchorage Development Services Division (DSD) issues Certificates of On -Site Systems Approval (COSA) based only upon the
representations given in paragraph 5 by an independent professional civil engineer registered in the State of Alaska. The Municipality of Anchorage is
not responsible for errors or omissions in the professional engineer's work.
7. ATTACHMENTS:
COSA Checklist X Nitrate Advisory_
Septic System Advisory Arsenic Advisory
Well Flow Advisory Other
COSA Checklist blue sheet
COSA Checklist
Legal Description: Rockhill B1 L6 Parcel ID: 015-362-14
If more than 1 septic system on lot: COSA Checklist # of Structure served by this system 1
A. WELL DATA
❑ Well log is filed with Onsite (or attached)
Date drilled 7/18/81
Total depth 80 ft
Cased to 80 ft
❑ Sanitary seal is functioning correctly
❑ Wires are properly protected
Casing height (above ground) 24 in.
Date of flow test for COSA 5/28/20
Static water level at beginning of test 38.8 ft.
Comments
B. TANK DATA
Age of tank(s) `1 years
Tank type/material septic plaStiC
Measured operating fluid level in septic tank
❑ Standpipes/foundation cleanout per record drawing
Date of pumping installed June 2020, OSP201160
D. ABSORPTION FIELD DATA
Which system tested (date installed) 918/81
© ALL standpipes present per record drawing
Total measured depth from grade 15.8 ft (max)
Measured depth to pipe invert from grade 93 ft (min)
❑ N/A — pressurized field
❑ Monitor tubes go to bottom of effective. If not, state
depth into effective
❑ Code -required soil cover over field
❑ System presoaked
(Required if vacant for greater than 30 days prior to
date of test)
Gallons introduced gallons
Comments/Deficiencies:
COSA Checklist yellow sheet
Well production at time of test 7.8 gpm
Water storage tank volumen/a gallons
Well disinfected for coliform test? ❑ Yes ❑ N
❑ Coliform bacteria is Negative
Nitrate 9.69 mg/L ❑ Nitrate less than MRL (ND)
Arsenic n/d ug/L ❑ Arsenic less than MRL (ND)
Collected by Brandon's On -Site Services LLC.
Date of Sample 5/28/20 .11
C. LIFT TATION
❑ Required ' tenance completed
Age of lift station years
Lift station material
Comments: \
Adequacy test date 5/28/20
Results Q Pass For 4 bedrooms
Fluid depth prior to test 0 in
Water added 606 gal
New depth 9 in
Elapsed time 15 min
Final fluid depth 0 in
Absorption rate 606+ gpd
Any rejuvenation treatment (past 12 months) no
If yes, enter date
E. SEPARATION DISTANCES
From Private Well on Lot to: (Please enter distances if less than required or if community well)
Septic Tank/Lift Station on Lot > 100'
❑✓
Yes
Community Sewer Manhole/Cleanout > 100'
ft
If absorption field is under driveway comment below
Q✓
Yes
if No
ft
❑✓ Yes
if No
ft
Neighboring Tank > 100'
M
Yes
if No
ft
Private Sewer/Septic Line > 25' [Z] Yes
if No
ft
Absorption Field on Lot > 100'
0
Yes
if No
ft
Holding Tank > 100' Q Yes
if No
ft
Neighboring Absorption Fields
> 100'
Animal Containment > 50' Q Yes
if No
ft
M
Yes
if No
ft
Manure/Animal Excreta Storage > 100'
Community Sewer Main > 75'
F,71
Yes
if No
ft
Yes
if No
ft
From Septic/Holding Tank on Lot
to: (Please
enter
distances if less than required)
Building Foundations > 10'
❑✓
Yes
if No
ft
Surface Water > 100' Q Yes
if No
ft
Property Line > 5'
0
Yes
if No
ft
Wells on Adjacent Lots:
Absorption Field > 5'
0
Yes
if No
ft
Private Wells > 100' Yes
if No
ft
Water Main > 10'
0
Yes
if No
ft
Community Wells > 200' Yes
if No
ft
Water Service Line > 10'
0
Yes
if No
ft
If septic tank is under driveway comment
below
From Absorption Field on Lot to: (Please enter distances if less than required)
Building Foundation > 10'
❑✓
Yes
if No
ft
If absorption field is under driveway comment below
Property Line > 10'
❑
Yes
if No 8
ft
Wells on Adjacent Lots:
Water Main > 10'
0
Yes
if No
ft
Private Wells > 100' ❑✓ Yes if No ft
Water Service Line > 10'
❑✓
Yes
if No
ft
Community Wells > 200' ❑✓ Yes if No ft
Surface Water > 100'
0
Yes
if No
ft
F. ENGINEER'S COMMENTS
Requested property line waiver June 2020.
G. ENGINEER'S CERTIFICATION
I certify that I have determined through field inspections and review
Of Municipal records that the above systems are in conformance with
MOA COSA guidelines in effect on this date.
COSA Checklist yellow sheet
all
co 1*
*Ti
1, s
Curtis T se d
CE 11
VQ��ja"PROFESSIONA�.��
MUNICIPALITY OF ANCHORAGE
DEVELOPMENT SERVICES DEPARTMENT 907-343-7904
On -Site water and wastewater Section Y Fax: 343-7997
www.muni.org/onsite
Nitrate Advisory
Certificate of On -Site Systems Approval # OSC 201291
Subdivision: Rockhill, Block: 1, Lot: 6
A water sample revealed a nitrate concentration of 9.69 milligrams per liter (mg/Q.
The Environmental Protection Agency (EPA) has established a maximum
contaminant level (MCL) of 10.0 mg/L for public drinking water systems. While
private wells are not subject to this regulation, EPA standards are based on existing
health information and can therefore be used to gauge the relative quality of water
from private wells. Please see the attached "Nitrate Fact Sheet" for important
information regarding nitrate.
This advisory must be attached to all copies of the subject Certificate of On -Site
Systems Approval.
Municipality of Anchorage
Development Services Department
Building Safety Division
On-Site Water & Wastewater Program
4700 South Bragaw SL
P.O. Box 196650 Anchorage, AK 99519-6650
www.cLanchorage.ak.us
(907) 343-7904
( ERTIFICATE OF HEALTH AUTHORITY APPROVAL
FOR A SINGLE FAHILY DWELLING
Parcel I.D. 015-362-14
1. GENERAL INFORMATION
Completelegaldescdption ROCKHILL SUBDIVISION; LOT 6, BLOCK 1
Location (site address or directions) 940O MAINTREE DRIVE * ANCHORAGE, AK 99516
Cu~Tent Property owner(s)
Mailing address
Lending agency
JOHN WATSJOLO Day phone 227-3832
9400 MAINTREE DRIVE * ANCHORAGE~ AK 99516
Day phone
Mailing address
Real Estate Agent
Mailing address
JAY EVENSON w/ PRUDENTIAL VISTA Day phone
· 4241 "B" STREET * ANCHORAGE. AK 99505
345-1234
Unlessotherw~emqueste~ HAAw~beheldbyDSD ~rp~k~.
2. NUMBER OFBEDROOMS: 4
3. TYPE OF WATER SUPPLY:
Individual Well
Individual Water Storage
Community Class Well
Public Water System
TYPE OF WASTEWATER DISPOSAL:
Indiv!dual On-site
Indiwdual Holding tank
community On-site
Public Sewer
The Municipality of Anchorage Development Services Department (DSD) Issues Certificates of Health Authority
Approval (HAA) based only upon the representations given in paragraph 5 by an independent professional civil
engineer registered in the State of Alaska. Certificates of Health Authority Approval are required for the transfer
of title (except between spouses) for properties served by a single family on-site wastewater disposal and/or
water supply system. DSD also issues HAAs upon request to homeowners. Certiticates of Health Authority
Approval are valid for 90 days from the date of issue for properties served by a private or Class C well and may
be reissued with new water sample results less than 30 days old. (Certificates may be reissued for a period of
up to one year with valid water samples.) Certificates are valid for one year for properties served by Class A or B
wells or a public water system. The Municipality of Anchorage is not responsible for errors or omissions in the
professional engineer's work.
i Note: Alaska Water and Wastewater Consultants, Inc. shall be paid $1000. O0 at, or pdor I
to closing for the engineering services provided.
4. STATEMENT OF INSPECTION BY ENGINEER
As certified by my seal affixed hereto and as of the validation date shown below, I verify that my
investigation, based on procedures outlined in the Health Authority Approval Guidelines for this application,
shows that the on-site water supply and/or wastewater disposal system is(am) safe, functional and adequate
for the number of bedrooms and type of structure indicated herein. I further vedfy that based on the
information obtained from the Municipality of Anchorage files and from my investigation and inspection, the
on-site water supply and/or wastewater disposal system is(am) in compliance with all applicable Municipal
and State codes, ordinances, and rogulations in effect at the time of installation.
Nameof Firm ALASKA WATER & WASTEWAT£R CONSULTANTS. INC. Phone
Address 6901 DEBARR ROAD, SUITE 2B * ANCHORAGE, AK 99504
Engineer's Printed Name JEFFREY A. CARNESS, P.E. Date
,357-6179
Engineer's Comments:
In conducting this evaluation, A WWC, Inc. attempted to provide a thorough,
conscientious engineering analysis of the system in accordance with ADEC and MOA
DSD Guidelines & Regulations. The reported results described the perten'nance of the
system under the conditions encountered at the time of the test, and separation
distances measured to readily identifiable features. The operational life of all wells and
septic systems depend on the local soils condition, groundwater levels that may
fluctuate durng the year, and the water usage of the family being served by the system.
These conditions are outside the control of the evatuator of the system. Satisfactory test
results do not guarantee future performance of the system, nor do they guarantee that
there are no hidden defects or encreachments. AW1/VC, Inc. can therefore not provide
any warreniy or futura estimate of how long the system will continue to meet the
operational requirements of the ADEC ar MOA DSD. The content of this report is for
the sole benetit of the owner listed above. Any reliance upon er use of this report by any
other peraon or pady is not authorized, nor will it confer any legal rght whatsoever.
DSD SIGNATURE
~ Approved for L{.- bedrooms.
Disapproved.
Conditional approval for bedrooms, with the fllowing stipulations:
NOTE: THE WELL FOR THIS PROPERTY MEETS EXISTING STATE AND
MUNICIPAL CODES. THERE ARE NITRATES PRESENT. IT IS SUGGESTED THAT
PERIODIC TESTING BE PERFORMED TO INSURE THE WELLS CONTINUED
SUITABILITY. CURRENT NITRATE CONCENTRATION IS 5.49 mg/L. EPA
MAXIMUM CONCENTRATION IS 10.0 mg/L. MORE INFORMATION ON NITRATES
IS AVAILABLE FROM THE ON-SITE SERVICES PROGRAM, AT 343-7904.
Attachments:
HAA Checklist
Septic System Advisory
Well Flow Advisory
Manitanance Agreements
Supplemental Engineer's Reort
Other
Original Certificate Date: / "~- - '.~'"' 0 t
L~gal Dascdpfion:
A. WELL DATA
Well t~pe PRrv^~
Municipality of Anchorage
Development Services Department
On. Slta Wster & Wastevmm' Program
4700 South Bragsiw 8L
P.O. 8ox lge850 Anchorage, AK gg51g-6850
HEALTH AUTHORITY APPROVAL CHECKLIST
ROCKHILL SUBDNISION; LOT 6, BLOCK 1 Parcel ID:
If A. B. or C provide PWSlD~ N/A
Oatacompleted 7/18/1981 Sanltary~eal (Y/N) YES
Total depth 80 fL Cased to 80 ft.
FROM WELL LOG
7/18/1981
40
Data of test
Static water level ft.
Well preduction 10+ g.p.m.
WATER SAMPLE RESULTS:
Coliform ~) colonies/100 mi.
Data of sample: 11/20/2001
SEPTIC/HOLDING TANK DATA
T;mk Type/Material STEEL
Tenkelze 1250 gal. Number of Compartments 2
Foundation deanout (Y/N) YES Depresslofl over tallk (Y/N) NO
Date of pumping 11/20/2001 Pumpe[
015-562-14
we, Log (Y/N).
Wlms pmpedy protected (Y/N)
Casing heigM (above ground)
AT INSPECTION
11/20/2001
¢0 ft.
4.6 ,g.p.m.
Other bactada ~
AWWC~ INC.
YES
YES
12+ in.
. colonies/100 ~.
9/8/ 981
Data installed
Clearmuts (Y/N) YES
High water alarm (Y/N) N/A
ISAACS PUMPING
New deplh
Absom~on rata >= 600+
NONE KNOWN If yes, give date
ABSOI~OTION FIELD DATA I*~ 0NI.Y EXTENDS ABOUT $0" BELOW INVERT.I
Data installed 9/e/lgel ~ rating (g.p.d./It~or~'~'n~ 85 System type DEEP TRENCH
Lenglh 54 fL Width 5 ,fL Gravel below pipe
Total depth 14.9 fL Eft. el:~Ol~on ama ,,%40 tt~ Monltaring lube *YES
Data of edequacy test 11/20/2001 Results (Pass/Fell) PASS
Fluid deplh in absorption field before test 0 in. Water added 698. gal.
Elapsed Time: 0 min, Final fiuld depth 0 in.
Any rejuvenation treatment (peet 12 mo.) (Y/N & type)
fL
Dapmsaion overfleld. NO
For 4 bedrooms
0 in.
g.p.d,
D. UFT STATION
Date installed Size In gallons .... ~, _ M~
'Pump on' level at in. 'Pump off' n, High water alarm level at ~ in.
~ Cycles tested Meets alarm & circuit requirements?.
Fe
Septic tank/lilt station on lot
.aJ3~fion field on lot.
Public sewer main
Sewer/septic seneca line
SEPARATION DISTANCES
SEPARATION DISTANCES FROM WELL ON LOT TO:
100'
100'+
N/^
25'+
SEPARATION DISTANCES FROM SEPTICfl'"IOLDINO TANK ON LOT TO:
Building foundation 5'+ Property line 5'+
Water main N/A Water sauce line, 10'+
Wells on adjacent lots 100'+
SEPARATION DISTANCE FROM ABSORPTION FIELO ON LOT TO:
Properly line 10'+
Water sendce line 10'+
Curtain drain NONE KNOWN
COMMENI~
. Building foundation 10'+
Surface water 100'+
Wells on adjacent lots 100'+
On adjacent lots lOO'+
On adjacent lots 100'+
Public sewer manhote/deanout
Holding tank N/A
N/A
Absorp~on field. 5'+
Surface water. 100'+
Water main N
On'veway, pa~ng/vehlclestorage 10'+
G. ENGINEER'S CER'nFICATiON
I cerZ~ that I have detenninnd through field inspec~/on~ and
mv~ew of Municipal taco.s that the a~x)ve a~em~ am In
conformance wff. h MOA HAA guidelines in effect on this date.
Engineer's Printed Name
Date I I /Z~,/D t
JEFFREY A. GARNESS
Dat. of Pa er l t-
Receipt Number (:~)150
Waiver Fee $
Date of Payment
Receipt Number.
MUNICIPALITY OF ANCHORAGE
DEPARTMENT OF HEALTH & HUMAN SERVICES
Division of Environmental Services
On-Site Services Section
P.O. Box 196650 Anchorage, Alaska 99519-6650
343-4744
Parcel I.D. #
CERTIFICATE OF HEALTH AUTHORITY
APPROVAL FOR A SINGLE FAMILY DWELLING
1. GENERAL INFORMATION
Complete legal description
Lot 6; Block I; RockhilISubdivZsion
Location (site address or directions) 9400 Main Tr¢~ Driv~
Property owner John E. & Kathl~n M. Wat~jold
Mailing address 9400 Main Tr~ Driv~ Anchorage.
Lending agency Alaska Hom~ Mortga,q~ B~rnad~tt¢
Mailing address 36th Av~nu~ Anchora9~,
'Addr(~ss
Day ohone 346-1134
- wk:762-7685
AlaSka 99516 ·
Day phone 563-3033
Alask~ 99503
Unless otherwise requested, HAA will be held for pickup.
NUMBER OF BEDROOMS: 4 'q
TYPE OF WATER SUPPLY:
Individual well
Community well
Public water
NOTE:
If community well system, provide written confirmation from State ADEC attest-
lng to the legality and status of system.
TYPE OF WASTEWATER DISPOSAL:
Individual on-site
Holding tank
Community on-site
Public sewer
NOTE: If community wastewater system, provide written confirmation from State ADEC
attesting to the legality and status of system.
72-025 (Rev. 1/91) Front MOA #21
sluewwoo leuoB!PPV
:suop, Blnd!~s §U!MOIIOt eq~ ql!M 's~uooJpeq
'SLUOOJpeq ..~
Jo,[ le^oJddB leUOB!puoo
'peAoJddBs!a
g~lnJ.VNIDIS SH Ha '9
euoqd
ZZS66 e~lSel¥ 'Je~la OlBe~]
'ON paoli dool ~eH~l elBe~l I~£0ZL
gNI~I~INIgN~1 $ ~' S
e~n3~u6!s s,Jeeu!l~u~]
sseJppv
~uJ!:l ~o eLUBN
· uop, oedsu! s{q~ ~o eTep eql uo loe~je u! suoB~ln6eJ pub 'seouBu!pJo
'sepoo el~),S pub IBd!o!UnlAI lib q~!M eOUB!IdLUoO U! S! LUelS~S IBSOdS!p ~ele~elSBM ~o/puB ~lddns
JelBM el!s-uo eqi 'uoBoedsu! pub uop, B6Bse^u! ~by byo~ pub Sel!J e6BJoqouv
LUO~,[ peu!B1qo uoBBLuJo~u! eql uo peseq 1BLI1/{jpe^~eq~n~ I 'u!e~eLI peTBo!pu! eJnlon~ls Jo ed,{i pub
sbyooJpeq ,[o Jeq~unu eq1 Jo,[ elBnbepe pub IBUOp, ounj 'e~es s! ,-els~s IBsods!p JelBMe~SBM Jo/pue
~lddns JeIBM ei!s-uo eql ~,Bq~ SMOqS uoBBo!IddB IB^o~ddv ~ipoqlnv q~lBeH s!ql ,to uo!1e6!Tse^u!
/{bY ~,BLp, ~JIJE)A I 'MOleq UMOqS elep uoBePlle^ eq~, jo se pue o3eJeq pexlJJB lees ~uJ Aq pe!j!~Jeo sv
t:I:I:INIIDN:I Ag NOI.LO::IdSNI -lO /N':IIN:I.LV.I.$ 'g
(~ Municipality of Anchorage
Department of Health & Human Services
HEALTH AUTHORITY APPROVAL CHECKLIST
Legal Description: ~ ~:> ~L-~-- . \ Parcel I.D.
A. WELL DATA
Well type~-~l~V~A'~c~ If A, B, or C, attach ADEC letter. ADEC water system number
Log presenl::~N)
Total depth
Sanitary sea~N)
Date completed "~ -- ~ ~ --~ ~, Driller
Cased to '~:~c>r Casing height
Wires properly protectedC~N) "/
FROM yELL LOG
Date of test "~ /SI
Static water level 4~t~==' ~
Well flow ~ ~ -Jr-
Pump level
SEPARATION DISTANCES FROM WELL TO:
Septic/holding tank on lot
Absorption field on lot
Public sewer main ~, '~
Sewer service line ~-~ -k
g.p.m.
; On adjacent lots
; On adjacent lots
Public sewer manhole/cleanout
Petroleum tank t--.~ ~ ~_
WATER SAMPLE RESULTS:
Coliform '~ Nitrate
Date of sam pie:
,~f..~gf' ~' ~ Other bacteria ~
Collected by:
B. SEPTIC/HOLDING TANK DATA
Date installed <:2[
Cleanouts~:~N)
High water alarm (Y/N)
Date of pumping
Tank size \ '~..~'~S:) Compartments
Foundation cleanout {5~;ZN) y Depression
.Alarm tested (Y/N) --
Pumper
SEPARATION DISTANCES FROM SEPTIC/HOLDING TANK TO:
Well(s) on lot [ ~::;>~ On adjacent lots
To property line ~c=- [ +' Absorption field
Surface water/drainage
Foundation
Water main/se rvice line
72-026 (Rev. 7/91) Front CONTINUED ON BACK PAGE
C. LIFT STATION
Date installed
Size in gallons
Vent (Y/N)
High water alarm level
"Pump on" level at
Manufacturer
Manhole/Access (Y/N)
"Pump off" level at
Cycles tested
Meets MOA electrical codes (Y/N)
SEPARATION DISTANCE FROM LIFT STATION TO:
Well on lot On adjacent lots
Surface water
D. ABSORPTION FIELD DATA
Date installed <c~ _
Length "¢~¢~ Width
Total absorption area
Depression over field (Y/~
Result~>/fail)
Peroxide treatment (past 12 months) (Y~
/
Soil rating ~ '¢"~-'~'~2 System type
Gravel thickness '~ ' Total depth
Cleanouts presentCCi~'N)
Date of adequacy test
for ~ bedrooms
If yes, give date
To building foundation
On adjacent lots '~
SEPARATION DISTANCE FROM ABSORPTION FIELD TO:
Wellonlot t, ¢:-¢:~ ~ On adjacent lots \ ~ ~ .Propertyline
To~xisting or abandoned system on lot
Cutbank ~/'~- Water main/service line
Surface water
Curtain drain
Driveway, parking/vehicle storage area
E. ENGINEER'S CERTIFICATION
I certify that I have checked, verified, or conformed to all MOA and HAA guidelines in effect on Lh~clate of this inspection.
S & S ENGINEERING ~'~'~, 'r~.,~,**'*'~*,,~,"~-e~ ~,
17034 Eagle Riv~ L~p Road No. 2~ ~ ~ .~ ~ ,. ~ ~.
Signature =..~. m ....~,..~ oo=~ ~ ~ ~,~,,, ~ = ~
HAA Fee $ [ 7~' ~ ~' Waiver Fee: $
Date of Payment ~ I ~ ' ! ~ Date of Payment
Receipt Number ~~7~ ~eceipt ~umbor
MUNICIPALITY OF ANCHORAGE
DEPARTMENT OF HEALTH AND ENVIRONMENTAL PROTECTION
DIVISION OF ENVIRONMENTAL HEALTH
CERTIFICATE OF INSPECTION FOR HEALTH AUTHORITY APPROVAL
OF ON-SiTE SEWER AND WATER FACILITY
264-4720
Application Date
GENERAL INFORMATION
(a) Legal Description (include lot, block, subdivision, section, township, range)
~ or ~ ~,'odP / ~o~'nH/~$ _~/z~, 7'1~ ~ ~ ~ ~ ~-~
Location (address or directions) '
(b)', Applicant Name ~O~ ~elephone: Home ~¢¢-~0 Business
~: Applicant ~dSress ' ' ~ ~00 ~¢/~¢ ~
(c) · Applicant is (check,one): Lending institution ~; Owner/builder ; Buyer ~; Other D (explain);
.... "' ~/~ Telephone
. .... ;,
(d) Lending Institution ~:
Address
(e) Real Estate company and Agent
Address
Telephone
(f)
Mail the HAA to the following address:
TYPE OF RESIDENCE
Single-Family,~ Multi-Family []
Number of Bedrooms +
Other
WATER SUPPLY
Individual Well J~ Community [] Public []
Note: If community well system, must have written conf rmation from the State Department.of Environmental Conservation
attesting to the legality and status.
SEWAGE DISPOSAL
Onsite,J~ PublicE]. Communityl-I ,Holding Tank []
Note: If community well system, must have written confirmation from the State Department of Environmental Conservation
attesting to the legality and status.
72-025 (11/84)
ENGINEERING FIRM PROVIDING INSPECTIONS, TESTS, FILE SEARCH, DATA AND INFORMATION
AS certified by my seal affixed hereto and as of the validation date shown below, I verify that my investigation of this Health
Authority Approval shows that the on-site water supply and/or wastewater disposal system is safe, functional and adequate
for the number of bedrooms and type of structure indicated herein. I further verify that based on the information obtained
from the Municipality of Anchorage files and from my investigation and inspection, the dh-site water supply and/or
wastewater disposal system is in compliance with all Municipal and State codes, ordinances, and regulations in effect on
the date of this inspection.
Name of Firm ~ ~"~--~f /~
Address [z~)O ~'/' ~'~ i~/ /¢Y~¢1
Date ~/~'~
Telephone
ApProved for ~--'c~, ~ be~i~m~tvYet~,'"/---vvl~~,~' /~ate
?~rmOsV~tcord~itionalApprova,' pp ~-~onditio~a~}
CAUTION
The Muncipality of Anchorage Department of Health and Environmental Protection (DHEP) issues Health Authority
Approval certificates based solely upon the representations given in paragraph 5 above by an independent professional
engineer registered in the State of Alaska. The DHEP does this as a courtesy to purchasers of homes and their lending
institutions in order to satisfy certain federal and state requirements. Employees of DHEP do not conduct inspections or
analyze data before a certificate is issued. The Municipality of Anchorage is not responsible for errors or omissions in the
professional engineer's work.
MUNICIPALITY OF ANCHORAGE (MOA)
HEALTH AUTHORITY APPROVAL (HAA)
CHECKLIST - FEBRUARY 1984
?
MUNICIPALITY OF ANCHOP. AGE.
DEPT. OF HEALTH &
ENVIRONMENTAL PROTECTION
?LgS
WELL DATA
Well Classification
Well Log Present (Y/N)
Total Depth ~ t
Static Water Level
Casing Height Above Ground 42° ~(O 7/~z
Electrical Wiring in Conduit (Y/N) /v
,,~"~/V/~ ~ If A, B, C, D.E.C. Approved (Y/N)
Y Date Completed '~"//'¢¢/'¢¢' / Yield
Cased to ~4:~ ~ Depth of Grouting
.~¢(~, /O //'¢4 Pump Set At
Sanitary Seal on Casing (Y/N)
Depression Around Wellhead (Y/N)
Y
I00 ' ~
Separation Distances from Well:
To SepticlH, o',di~,g Tank on Lot
To Nearest Edge of Absorption Field on Lot
To Nearest Public Sewer Line
/,4
Cleanout/Manhole
; On Adjoining Lots
//~O f ¢ ; On Adjoining Lots
To Nearest Public Sewer
To Nearest Sewer Service Line on Lot
Water Sample Collected by
Water Sample Test Results
Comments
B. SEPTIC/HOLDING TANK DATA
Date Installed
Standpipes (Y/N) /V'
Depression over Tank (Y/N)
Pumping/Maintenance Contract on File (Y/N)
Holding Tank High-Water Alarm (Y/N) /V/~
Separation Distances from Septic/Holding Tank:
To Water-Supply Well
To Property Line
To Water Main/Service Line
Course ,/~'/./~
Size /Z_~O~
Air-tight Caps (Y/N)
No. of Compartments
O
'.Y' Foundation Cleanout (Y/N)
Date Last Pumped
/V/,4 ;for /V/,,.~
Temporary Holding Tank Permit (Y/N) ///,¢~
To Building Foundation .¢/O /
To Disposal Field /~ ~
To Stream, Pond, Lake, or Major Drainage
Page 1 of 2
C. ABSORPTION FIELD DATA
Soils Rating in Absorption Strata
Date Installed ~'/,~ /
Width of Field -~'
Square Feet of Absorption Area --~'~
Depression over Field (Y/N) /~
Results of Last Adequacy Test ¢-
/
Type of System Design ~:~"P
Length of Field ---~¢
Depth of Field ~:)
Gravel Bed Thickness
Standpipes Present (Y/N)
Date of Last Adequacy Test
/
Separation Distance from Absorption Field:
To Water-Supply Well
To Building Foundation
Lot
To Water Main/Service Line
To Stream/Pond/Lake/or Major Drainage Course
To Property Line /'~ ~ '¢'
To Existing or Abandoned System on
; On Adjoining Lots ~) /"<:~:~ /
To Cutbank (if present) ~'~" ~
To Driveway, Parking Area, or Vehicle Storage Area
/
/ / / /
D. LIFT STATION
Date Installed
Size in Gallons
"Pump On" Level at
High Water Alarm Level at
Man hole/~N'"~
~~~,./",~mmp Off" Level at Vent (Y/N)
Tested for
Electrical Codes (Y/~ .~'~'~
Pumping Cycles during Adequacy Test. Meets MOA
** Check Permitted Bedroom Rating Against HAA Request **
I certify that I have checked, verified, or conformed to all MOA and HAA guidelines in effect on the date of this inspection.
Signed Date
7
Company /,/~'~-~'~',~/ /kfE', MOA No.
Receipt No. -"~--~ ~' ! S %/
Date of Payment ~:~
Amount: $
Page 2 of 2
72-026 (11/84)
ALASKA ENVIRONMENTAL
CONTROL SERVIf~'~, INC.
1200 West 33rd Avenu=. Suite B
ANCHORAGE ALASKA 99503
(907) 56:1-5040
JOB
CALCULATED BY ~- ~/'~:~'~;> -~ DATE
CHECKED BY- 3ATE
SCALE IP~ZO /
OF HEALTH &
0 ? 1986
D
i D,g, TE RECEIVED
, INSPECTION APPOINTMENTS ¢, ~ ~
DATE DATE ~ DATE
MUNICIPALITY OF ANCHORAGE IPALITY OF ANCHORAGE
DEPARTMENT OF HEALTH & ENVIRONMENTAL PROTE~EPT' OF HEAL~I~ &
825 L Street - Anchorage, Alaska 99501 ENVIRONMENTAL p[~oTECTiON
ENVIRONMENTAL SANITATION DIVISION SEP
Telephone 264-4720
DIRECTIONS: Complete all parts on page 1. Incomplete reques~ will not be processed. Please allow ten (10) days for processing.
1. PROPER~Y OWN~ ..... PHONE
PROPERTY R~siD~NT (If different from above) t PHONE
'2. BUYER ~ PHONE
MAI LING ADDRESS
3. LENDIN~STITUTION ~, PHONE
4. REALTOR/AGENT
PHON~
5. LEGAL.DESCRIPTION
;TREET LOCATION
6. TYPE OF ~ESIDEI~CI~ ' ~ SINGLE FAMILY
[] MULTIPLE FAMILY
NUMBER OF~BEDROOMS
[] One [~ Four
[] Two [] Five
[] Three [] Six
[] Other
7. WATER SUPPLY
' INDIVIDUAL*
COMMUNITY
[] PUBLIC UTILITY
*ATTACH WELL LOG. A well log is required for all wells drilled
since June 1975. For wells drilled prior to that date, give well
depth (attach log if available.)
8. SEWAGE DISPOSAL SYSTEM
~J INDIVIDUAL/ON-SITE**
[] PUBLIC UTILITY
YEAR ON-SITE SYSTEM WAS INSTALLED.
NOTE: THE INSPECTION FEE MUST ACCOMPANY EACH REQUEST BEFORE PROCESSING CAN BE INITIATED.
72-010 (Rev. 6/79) ~l [ ~
THIS SIDE FOR OFFICIAL USE ONLY
1. TYPE OF RESIDENCE NUMBER OF BEDROOMS
[] SINGLE FAMILY [] ONE [] THREE [] FIVE [] OTHER
[] MULTIPLE FAMILY [] TWO [] FOUR [] SIX
PERMIT NUMBER
2, WATER SUPPLY
[] INDIVI DUAL DEPTH OF WELL
[] COMMUNITY
DATE DRILLED
[] PUBLIC UTILITY
Connection Verified LOG'RECEIVED
3. SEWAGE DISPOSAL SYSTEM PERMIT NUMBER
[] INDIVI DUAL/ON -SITE DATE INSTALLED
[]PUBLIC UTILITY (::~---(~ {
Connection Verified iNSTALLER '
[]Sept;ic Tank. or [] Holding Tank
Size:~-3 If Tank is homemade SOILS RATIN(~
give dimensions:
TYPE OF TANK MANUFACTURER ~ ~ ~, _ ~
TOTAL ABSORPTION AREA MATERIAL
4. DISTANCES Septic/Holding Tank Absorption Area ISewer Line I Nearest Lot Line
I
t
WELL TO:
Absorption Area to nearest Lot Line
5, COMMENTS
[~APPROVED FOR' ~ BEDROOMS
[] CONDITIONAL APPROVAL (letter must acco~any certificate)
[] DISAPPROVED
DATE BY ~~