HomeMy WebLinkAboutGLENN VIEW ESTATES WEST PH 2 BLK 2 LT 20Glenn View
Estates West
#2
Block 2
Lot 20
#051 - 793 - 37
Anchorage
. Municipality of
Services Department
4,
,�_
,,
���
Development
Building Safety Division
,r--
On-Site Water & Wastewater Program, 4700 South Bragaw St.
P.O. Box 196650 Anchorage, AK 99519-6650
www.ci.anchorage.ak.us (907) 343-7904
On-Site Wastewater Disposal System and/or Well Inspection Report
SW060203 PID Number: 051-793-37
Page 1
of 3
Permit Number
Name:
JOHN BOBICH
Wastewater System: 0 New ■Upgrade
21304 POLLY CIRCLE * CHURGIAK, AK 99567
ABSORPTION FIELDAddress:
(907) 317-3228 4 Phone: No. of Bedrooms:
O Deep Trench O Shallow Trench O Bed O Mound
I ■Other
LEGAL DESCRIPTION
Soil Rating:
0.7 AVG spa,:,. n.
Taal Depth Iran enrol
peer:
SEE DWG. n.
Block: Lot: Subdivision:
2 20 GLENN VIEW EST. W. PH. 2
Depth to pipe bottom horn origami Erode:
SEE DWG. n.
Grovel depth beneath
pipe 3 n
Township:Range: — Section: —
N added *bore onglna grade`
SEE DWG. n.
Garel length:—
100 n.
_
WELL: ❑ New 0 Upgrade
Gravel
Gravel width:
Gravel5 n
Number of line
1
Delano. between Ines:
i<
Cb.ortw.uon (prlret.. A.9.C%
Dosed 1Netzwpc,D
n
Total abeorpuo• snot
862 so. n.k.�.gD
p . malarial:
3034/
l
F-810
wk1Cj
a W, Dote DWI:
Static Noted Levet
ln.`own GEG Ltd.
Date
i/ 18-19/2006
MMv`.C(
Yeld�Fusty awl AL
s� pL
Casing height Nan eraana FL
TANK
SEPARATION DISTANCES
°Septic OHolding 0S.T.E.P.
I • •her
7o
Septi.
Tank
Absorption
field
Litt
Station
Holding
Tank
pubf Lin to
Sewer Linn
Nawloctfl4
7
Co•• .• edbre:
i
I
From
well
—
200'+
—
—
—
�`CI\NCj
Wterd: E
Number of comp.NmwNv
I
Surface Water
—
100•+
—
—
—
LIFT STATION
1
Lot Line
—
10'+
—
—
—
Ste In yellow:
M•nl'r•chne:
I
Foundation
—
10•+
—
—
—
en ins eL
. ane el le..l
et
c •r alone
at.
Pump Yoe. * . •.
. local inspections
p.rio nwd by.
Curtain Drain
NONE KNOWN
Remarks: INTEGRITY
OF EXISTING SEPTIC TANK VERIFIED.
BENCH
MARK
L«oh.n ane Descripben
TOP OF BOTTOM STEP
OF DECK
a.•ned (Imola 100.00 .
Inspections by: GEG, Ltd. Dates: 1st 7/16/2006
ENGINEERS SEAL
0p
performed
2nd 7/19/2006
QF. q�;�o0
3rd
P�,
%�• - 0
Development Services Department Approval
p
by:td0 Date• S -Al- 06
•# �. ' % �* SOD
Y/
p. P
Reviewed and approved
•
CE-795 ot;:O
by: Date:
Ott :000000a
Reviewed and approved
(Rev. 4/06)
PERMIT NUMBER:
SW060203
AS—BUILT DRAWING
PARCEL ID NUMBER:
051-793-37
A
B
FD
27.9
24.5
DBL1
28.3
27.3
DBL2
26.6
28.2
CO1
55.2
74.0
MT1
55.7
76.0
CO2
86.3
60.5
MT2
83.2
57.4
5
E:
1 - 40'
NTT
two COG. 00uA7
'TELT 1110L.0
NEW DRMNFIELD
2
131.1 & D012
hoe—P.
Fpa
•
�-• EXISTING 1250
GALLON SEPTIC TANK
EXISTING DRAINFIELD
310210 lllOd
r
GARNESS ENGINEERING GROUP, Ltd.
CONSULTANTS & GENERAL CONTRACTORS
3701 C Ma Row. N11[ 101 • M41Cewf. Mf WO? • e.c,[ (104330-0170 • FaX (101)331-3244 • 110511T4 ewp••••,•y.—M•R•
PAGE NUMBER:
2 OF 3
PREPARED FOR:
JOHN BOBICH
PHONE NUMBER:
317-3228
LEGAL DESCRIPTION:
GLENN VIEW EST. WEST PH 2, LOT 20, BLOCK 2
DRAWN BY:
B.F.M.
0
/ J f re A. porness.
QQO s E-7951//`�DO
�Q7e. •'•46.(19•tcejd
0 ��professto�°o'
TYPE or WORK:
AS—BUILT FOR NEW DRAINFIELD
(Rev. 01105)
DATE:
7/31/2006
PERMIT NUMBER:
SW060203
AS -BUILT DRAWING
FINAL GRADE - (97.28 NORTH SIDE) -98.78
INSULATION OVER 70' OF NORTH END
FILTER FABRIC
INVERT OF PIPE
g• 94.76
BOTTOM OF
TRENCH . 91.75
r'
GARNESS ENGINEERING GROUP, Ltd.
CONSULTANTS & GENERAL CONTRACTOR � �
ITT L TKO* 0000. SSR 101 • 0110€10/04M MSD) • w[ ,0, (007)337-0170• IM (007)100-32011
PREPARED FOR: I PHONE NUMBER: I PAGE NUMBER:
JOHN BOBICH 317-3228 3 OF 3
LEGAL DESCRIPTION:
GLENN VIEW EST. WEST PH. 2, LOT 20. BLOCK 2
TYPE OF WORK:
AS -BUILT FOR NEW DRAINFIELD
(ROV. 01/05)
DRAWN BY:
B.F.M.
DATE:
7/31/2006
MUNICIPALITY OF ANCHORAGE
Development Services Department
On -Site Water & Wastewater Program
4700 South Bragaw Street
P.O. Box 196650, Anchorage, AK 99519-6650
(907) 343-7904
ON-SITE WASTEWATER DISPOSAL SYSTEM PERMIT
Upgrade
71/ t r
7�� q 'r
Date Issued: Jul 13, 2006
Expiration Date: Jul 13, 2007
Permit Number: SW060203 Parcel ID: 051-793-37
Legal Description: GLENN VIEW ESTATES WEST PH 2 BLK 2 LT 20
Design Engineer: 0855 GARNESS ENGINEERING GROUF Site Address: 021304 POLLY CIR
Owner Name: JOHN BOBICH Lot Size: 40100 SQ. FT.
Owner Address: 21304 POLLY CIRCLE Total Bedrooms: 4 Permit Bedrooms: 4
CHUGIAK , AK 99567 -
This permit is for the construction of:
❑✓ Disposal Field ❑ Septic Tank ❑ Holding Tank ❑ Privy ❑ Private Well ❑ Water Storage
All construction must be in accordance with:
1. The attached approved design.
2. All requirements specified in Anchorage Municipal Code Chapters 15.55 and 15.65 and the State of Alaska
Wastewater Disposal Regulations ( 18AAC72 ) and Drinking Water Regulations ( 18AAC80 ).
3. The engineer must notify DSD at least 2 hours prior to each inspection. Provide notification by calling
(907) 343-7904 ( 24 hours ). ( Not required for a Water Supply Permit only ).
4. From October 15 to April 15, a subsurface soil absorption system under construction during freezing weather
must be either: A. Open and closed on the same day.
B. Covered, sealed, and heated to prevent freezing.
S/OG awl" c to 3i. a%, 41h
Received By:
Issued By:
Date.
Date: %43,06
Parcel I.D.
Municipality of Anchorage
Development Services Department
Building Safety Division
On -Site Water & Wastewater Program
4700 South Bragaw St.
P.O. Box 196650 Anchorage, AK 99519-6650
www.c.i.anchorage.ak.us
(907) 343-7904
ON-SITE SEWER/WELL PERMIT APPLICATION
FOR A SINGLE FAMILY DWELLING
05- ?'1332
Property owner(s) JOHN BOBICH Day phone 317-3228
Mailing address 21304 POLLY CIRCLE. CHUGIAK. AK
Site address Zip Code 99567
Legal description (Sub'd, Block & Lot) GLENN VIEW ESTATES WEST S/D j7: BLOCK 2 LOT 20
Legal description (Township, Section & Range) N/A
Lot Size 116 , � Ob Acre
THIS APPLICATION IS FOR ( [gall that apply):
Number of Bedrooms 4
THIS APPLICATION IS AN:
Absorption Field 0 Initial 0
Septic Tank 0 Upgrade 0
Holding Tank 0 Renewal 0
Privy 0
Private Well 0
Water Storage 0
certify that the above information is correct. I further certify that this application is being made for a
Single Family Dwelling and is in accordance with applicable Municipal codes.
GARNESS ENGINEERING GROUP, Ltd.
Permit/Rush Fees• cy/( 0 f / % 5 fl'S &Waiver Fees:
Date of Payment:
Date of Payment:
Receipt Number: n S 0 yU �' 9 P Receipt Number:
(Rev. 11/05)
GARNESS ENGINEERING GROUP, Ltd.
July 11, 2006
CONSULTANTS & GENERAL CONTRACTORS
Municipality of Anchorage
Development Service Department
On -Site Water & Wastewater Program
4700 South Bragaw Street
P.O. Box 196650,
Anchorage, Ak 99519-6650
(907) 343-7904
at z.
Ref: Proposed Septic Upgrade for Glenn View Estates West SID; Lot 20, Block 2,
To whom it may concern:
The existing 4 bedroom house is served by public water and a private septic system. The septic
system consists of a 1250 gallon septic tank and a 5 -wide type drainfield. On 6/30/2006, we
performed a septic adequacy test for the purpose of selling the home and found the system did
not absorb the 600 gallons per day. It should be noted that the system was filled to it maximum
capacity during our test. Based upon this information, the septic system is in the state of failure
and needs to be upgraded. We are proposing to use the existing 1250 gallon septic tank and that
the alternate site for a new 5 -wide trench type drainfield be installed as shown on the attached
KND Engineering site plan. We are proposing that a confirmation test hole be excavated and a
percolation test be performed prior to the construction of the alternate site. Based upon our
experience in this subdivision, it is our opinion that a 0.6 application rate should be used for the
alternate site. Comments regarding the design are summarized as follows:
1. SOILS: See the attached two KND Engineering Togs which shows the soil classifications,
groundwater monitoring, and the percolation test results. As stated before, it is our opinion that
an application rate of 0.6 gallons/day/ft2 should be used.
2. TRENCH DESIGN:
a. Percolation Rate: 4.21 & 12.31 minutes/inch
b. Proposed Application Rate: 0.6 gallons/day/ft2
c. Number of Bedrooms: 4
d. Design Flow: 600 gallons per day
e. Minimum Absorption Area: 1000 ft2
f. Total Depth: 7 feet (maximum)
g. Effective Depth: 4 feet (minimum)
h. Width: 5 feet
i. Reduction Factor: 0.50
j. Minimum Length: 100 feet long
k. Effective absorption area = 1000 ft2
3701 E. Tudor Road, Suite 101 • Anchorage, AK 99507
Ph: (907)337-6179 • Fax: (907) 338-3246 • Website: gamessengineering.com
3. SURFACE WATERS: There are no surface waters within 100 feet of the proposed septic
system.
4. TOPOGRAPHY: The average slope in the area is a 5 to 10 percent running approximately
east to west. In short, there are no slope concerns.
We are unaware of any adverse impacts this installation would have on adjacent wells or septic
systems. If you have any questions, please contact us at 337-6179. Thank you for your
assistance.
ely
effre
Pres:
s, P.E., M.S.
NOTE: A 7 page construction specification letter is attached which is part of the design package
for this septic system.
3701 E. Tudor Road, Suite 101 * Anchorage, AK 99507
Ph: (907) 337-6179 * Fax: (907) 338-3246 * Website: gamesscngineering.com
AS-BUILLSYSTEM DETAILS/SITE PLAN Pernit 1t SW010087
GLENN VIEW ESTATES WEST S/D, LOT 20, BLOCK 2 PIDtt 05I-793-37
Atta.04.7t _erre Ti
$f tat'TALL O . 5CE
Dena Lcrret,
av
(8099-2/20
c
-$cPiic"�t
Y
Ta
T1PCRC 01-1
Wk.
,ST
xtSTM6 e
0Rh tent
tRtvc
BMI
Lot 20
FaaPeseo C.aF4.M11T,e44
ltt 11at.t
1311.400Wkr"r0 Qstiod_
(OA C7(WL'I1 ar)
SCALE. 1' • 50'
A -C=20.4'
B -C=16.8'
A -D=26.2'
B -D=22.4'
A -E=39.5'
B -E=62.8
A -F=64.5
B -F=37.4
«>
V
�}1
n
a a as a6
iII=II= = -1.411111=p
ag 1250 GAL _ir
t"'
R: SEPTIC iI I
TANK
i
88.9
88.8
I.S
Wit IM.KN
FINAL GRADE
► -II-O -•I-II it -u -n= =n-nuTn=a=n.=nv
OF AL \
4
r3s1011/+
SEVER ROCK
84.3
1
Se
81.3
PREPARED FOR:
TURNER CONSTRUCTION
PO BOX 3489
PALMER. AK 99615
(907) 713-8334
e.10 D0H
Scale: NTS
PAGE 1 OF 1
raw ROOKS mann
tQ"O'"It I ANC swot .11AAY
sun* LANG d ettet KMD
Ana% LANG Mme' 12/07/01
nn o+c NW1459
*C PIL 010026.DW a b 010026
END ENGINEERING
20441 PTARMIGAN BLVD.
EAGLE RIVER, MC 99577-6736
(907)698-6111/FAX (907)696-8111
2
11C IDENGINEERING
20441 PTARMIGAN BLVD.
EAGLE RIVER,-,1C995ii-tiilb
SOILS PERCOLATION TEST
Performed for: Arctic Devco
Project
Depth
(Tett)
Date Performed
1
1
1
2
4
_ ,,.-...;
ea, ... doe
'f
Pit %sTti ?•1,•�/
`• ••:. .•:
1
1
KND ENGINEERING
20441 PTARMIGAN BLVD.
EAGLE RIVER, AK 99577-8736
Performed for.
Project:
Depth
10-
11-
12-
13-
14-
15-
16-
17-
18-
19-
20 -
SOILS PERCOLATION TEST
Turner Construction
Glenn View West Estates Phase 2 B2, L20 TESTHOLE it
••
1.
Pit•• c2 •
• ••,'f-9 c
-STH .+/
...........:,_,k3
K•nnr,, M. L' -L•
4'..• CE7116 V 5
Icte l le P •••ESSIO • ..r
Date Performed: 4/27/01
Org/CP—w/ red -brown
overburden & loose gravel
SM/GM—med dense gray
w/cobbles to 8; dry
MATERIAL CONSISTENT
ALONG TRENCII
B.O.H.-TRENCH
FIOLE PRESOAKED
mom TO TEST
0I.1
I SEE ATTACHED SITE PLAN I
FOR HOLE LOCATION
IWas Ground water encountered? NO
Depth to water atter monitoring? NA
What depth? NA
Date? NA
Reading
Date
Cross
Time
Net
Time
Depth to
Water
1
4/28/01
1:00
6"
Net
Drop
2
130
30 min
38/16"
2 8/16'
3
•
131
6"
4
2:01
30 min
39/16"
2 7/16'
5
•
2:02
•
6"
6
2:32
30 min
3 9/16"
2 7/16"
•
Water
Added
Percolation Rate 1? 11, (min/in) Pere Hole Diameter 6"
Test RunBctween 7 ,feet and 8 •feet
f, Kenneth M. Duffus, certify that this test was performed In accordance with alt State and Municipal guidelines In
effect on this date.
Municipality of Anchorage :r
;' °•,
•/'r
1_ Development Services Department :Snail:
Kc -, ,; Building Safety Division
\
A
- On-Site Water and Wastewater Program. 4700 S. Bragaw St.
P.O. Box 196650 Anchorage. AK 99519-6650 Page
www.d.anchorage.ak.us (907) 343-7904
ON-SITE WASTEWATER DISPOSAL SYSTEM AND/OR WELL INSPECTION REPORT
Permit Number. SW010087 PID Number. 051.793.37
/
of
Turner Construction
Wastewater System:
'2 New 0 Upgrade
Address:
PO Box 3489. Palmer. AK 99645
ABSORPTION FIELD
Phone: Number or Bedrooms:
4
141 O Bed O Mond O Other:
D Deep trench Shallow trend,
LEGAL DESCRIPTION
Sod Rating:
p.
0.8 GPD/W27
taD.pthp�«.w..
W
7.0 Ft.
Block: Lot BubG.twn:
2 20 Glenn View West Est. Phase 2
Iran
Grave depth beneath pips
4.09 FL
Depth b pips bottom original grade:
2.91 Ft.
towshp: Ran' pe: Swoon:
Fa added above oglnel grade:
1.44 Ft.
Growl Length:
82 Ft.
Well: •
New ■ Upgrade
Grew wdt:
5 Ft.
Number of Yves: Distance between Mies:
1 NA Ft
Ciawbcabon (Pnmb, A B, cF
Public Water
Total Depth:
Ft.
Geed to:
n.
trxa abeap on area:
820 Fr
Pp Matew:
SCH40 & F810
Dnuar.
Date Dwell:
Static WoW Lew:
FL
pietaW:
Turner Const.
Dat. lnewbd:
4/28/01
Yield:
GPM
Pump 5e at
FI.
Casing Hewn Above Growd:
FL
TANK
SEPARATION DISTANCES
t83 Septic 0 Holding • S.T.E.P. 0 Other.
To
From
Septic
Tank
Absorption
Field
Litt
Station
Holding
Tank
Pudic/Private
Sewer cane
Manufacturer:caviar:
Anchorage Tank
1250 Get.
Wel
200'+
200'+
200'+
NA
NA
25'+
Material:
Number d Co.paanets:
2
Surface water
100'+
100'+
NA
NA
LIFT STATION
IAune
5+
10'+
NA
NA
Sins
Gal.
Hamada kae.
Foundation
5'+
10'+
NA
NA
'Pump on' level at
n.
*Pump off leve atNgh
n.
wets alarm at
h.
Curtain Drain
NA
'SO'+
NA
NA
Pump Make & Madel
Saimaa Inspections pnnamed by
*nonne known
no
BENCH MARK
Location and Damp a .%
Bottom of siding
Assumed Lb.aban.
100 FL
- Engineer's
.4c.•OF 4(gstl,
i x f g N - -
refi
Stamp assn.
.. �c to
Inspections performed by: KND Engineering Dates: 1M 4/27/01
Ir.001
Development Services Department App ov�j Slot
�` Date:/o--/9-
Reviewed and approved by: ,�/•a••
�1•••Kanne:h M•�d;t•
143% 4 3S GE 7115
4 Fyeo ..,.e..-�•, •
,1,� 0�V4InP�a
W tsi
i
!&S
(Rev. I2/00)
AS—BUILT SYSTEM DETAILS/SITE PLAN
GLENN VIEW ESTATES WEST S/D, LOT 20, BLOCK 2
Permit # SW010087
PID# 051-793-37
KD
KND99-2/20
T
—igsTINO
T
TII/PERC 01-1
14.
DRIVE
EXISTING 4
HRH HOUSE
BM
Lot 20
A -C=20.4'
B -C=16.8'
A -D=26.2'
B -D=22.4'
A -E=39.5'
B -E=62.8
A -F=64.5
B -F=37.4
0
FINAL GRADE
aftail-lAsib:
i= woks
13
84.34 84.3 I H
=li=11=11=11.-11-11-111=
., 1250 GAL
111-
41: SEPTIC I: —
TANKII
II I II IIII=
SEWER ROCK
45c) 9.A.44
;57„
.4
H M. DU
#CE -7116
....................
IPOFESS1014A.
wNIICt.•16:111.*
132'
4-09'
PREPARED FOR:
TURNER CONSTRUCTION
PO BOX 3489
PALMER, AK 99645
(907) 745-8334
(-78.10.)BOH
Scale: NTS
PAGE 1 OF 1
FIELD BOOKS
CC4841.1110:
inniUlt LANG
WtA". JMAY
SWUNG' LANG
"e'icct KMD
Main LANG
°ATE' 12/07/01
END ENGINEERING
20441 PTARMIGAN BLVD.
EAGLE RIVER, AK 99577-8736
0.44. 41-C;
cite. NW1459
" n't 010026.DWG Na: 010026
(907)696-6111/FAX (907)696-8111
KND ENGINEERING
20441 PTARMIGAN BLVD.
EAGLE RIVER, AK 99577-8736
SOILS PERCOLATION TEST
Performed fon. Turner Construction
Project:
Depth
Feet
OF4 �l
'(E....•...,zgs�+
in to•
TH •...t s'k o
.1
i
c. Kenno:n M. C -.;w L..,.,
fy CE7116 `C✓
• F�.r
t`1��\vim SS\0 .• "a
Date Performed: 4/27/01
Glenn View West Estates Phase 2 B2, L20
TEST HOLE # 01-1
Org/GP — w/ red -brown
overburden & loose gravel
SM/GM — med dense gray
3- ri .'" w/cobbles to 8", dry
5-
6-
7-
8-
9-
10-
11-
12-
13-
14-
15-
16-
17-
18-
19-
20 -
MATERIAL CONSISTENT
ALONG TRENCH
B.O.H. - TRENCH
HOLE PRESOAKED
PRIOR TO TEST
SEE ATTACHED SITE PLAN
FOR HOLE LOCATION
Was Ground water encountered? NO
Depth to water after monitoring? NA
What depth? NA
Date? NA
Reading
Date
Gross
Time
Net
Time
Depth to
Water
Net
Drop
1
4/28/01
1:00
-
6"
-
2
1:30
30 min
3 8/16"
2 8/16"
3.
1:31
-
6"
-
4
2:01
30 min
39/16"
2 7/16"
5•
2:02
-
6"
-
6
2:32
30 min
39/16"
2 7/16"
*
Water
Added
Percolation Rate 12.31 (min/in Perc Hole Diameter 6"
Test Run Between 7 feet and 8 feet
I, Kenneth M. Duffus, certify that this test was performed in accordance with all State and Municipal guidelines in
effect on this date.
MUNICIPALITY OF ANCHORAGE
Development Services Department
On -Site Water & Wastewater Program
4700 South Bragaw Street
P.O. Box 196650, Anchorage, AK 99519-6650
(907) 343-7904
ON-SITE WASTEWATER DISPOSAL SYSTEM PERMIT
Initial
¢ -2.7—o/
/ire, l2:00a'
2 .f' : O O p. w .
tot co 4.A.
Date Issued: Apr 26, 2001
Expiration Date: Apr 26, 2002
Permit Number: SW010087 Parcel ID: 051-793-37
Legal Description: GLENN VIEW ESTATES WEST PH 2 BLK 2 LT 20 •
Design Engineer: 0070 KND Engineering
Owner Name: TURNER CONSTRUCTION
Owner Address: PO BOX 3489
PALMER . AK 99645 -
Site Address:
Lot Size: 40100 SQ. FT.
Total Bedrooms: 4
Permit Bedrooms: 4
This permit is for the construction of:
E✓ Disposal Field 0 Septic Tank Holding Tank 111 Privy ❑ Private Well Water Storage
All construction must be in accordance with:
1. The attached approved design.
2. All requirements specified in Anchorage Municipal Code Chapters 15.55 and 15.65 and the State of Alaska
Wastewater Disposal Regulations ( 18AAC72 ) and Drinking Water Regulations ( 18AAC80 ).
3. The engineer must notify DSD at least 2 hours prior to each inspection. Provide notification by calling
(907) 343-7904 ( 24 hours ). ( Not required for a Water Supply Permit only ).
4. From October 15 to April 15, a subsurface soil absorption system under construction during freezing weather
must be either: A. Open and closed on the same day.
B. Covered, sealed, and heated to prevent freezing.
P/7 '7 —0/
Received By: Date:
Issued By:
Date: 4 - 2 7 — 0/
Municipality of Anchorage
Development Services Department
Building Safety Division
On -Site Water and Wastewater Program
4700 South Bragaw St.
P.O. Box 196650 Anchorage, AK 99519-6650
www.ci.anchorage.ak.us
(907) 343-7904
ON-SITE SEWER/WELL PERMIT APPLICATION
FOR A SINGLE FAMILY DWELLING
Parcel ID 051-793-37
Permit Number SW 010087
Property owner(s) Turner Construction Day phone 242-4555
Mailing address (1) PO Box 3487, Palmer, AK
Mailing address (2) Jip Code 9 9 6 4 5
Legal description (Lot, Block & Sub'
Legal description (Section, Township & Range)
Lot Size 40"800+ Acres q.Ft. Number of Bedrooms 4
d,) Lot 20 lock 2,Slenn View Estates West Ph 2
THIS APPLICATION IS FOR:
Sewer Only
Sewer and Well
Sewer Upgrade
THIS PROPERTY CONTAINS:
® Well Only
❑ Water Storage
0
Hot Tub 0 Jacuzzi
Swimming Pool 0 Water Softening Unit
Therapy Pool 0
I certify that the above information is correct. I further certify that this application is being made for a
Single Family Dwelling and is in accordance with applicable Municipal Codes.
(Signature of property owner or authorized agent)
Permit Fees: 037-0 — Waiver Fees:
Date of Payment: 0f/2o,/off Date of Payment:
Receipt Number: 3(.4q'/ r Receipt Number:
(Rev.12100)
KND ENGINEERING
20441 PTARMIGAN BLVD.
EAGLE RIVER, AK 99577-8736
(907)696-6111/FAX (907)696-8111
April 18, 2001
Municipality of Anchorage
Development Services Department
On -Site Water & Wastewater Program
P.O. Box 196650
Anchorage, AK 99519-6650
Subject: New sewer permit — Glenn View Estates West, Block 2, Lot 20
Gentlemen:
The owner has requested we proceed forward to obtain a septic permit on the subject
lot. On April 21, 1999 we dug one testhole for the proposed system. The results of the
test are attached. The general slope of this lot is from east to west at a grade of
approximately 5 - 8%. We have designed our system utilizing the testhole we
excavated for the 4 -bedroom house, which is proposed for this lot. The lot will be
served by, public water. We propose to install a 5' wide shallow trench. Water was not
encountered during the excavation or monitoring. An additional percolation test will
be conducted during construction.
There are no public or private wells within 200' of our proposed system location except
as noted. There is no surface water within 100' of the proposed system and there are no
known curtain drains within 50'. We do not expect there to be any adverse effect on
adjacent lots by the development of this system.
If you have any questions, please contact me at 696-6111/FAX 696-8111.
Respectfully submitted,
IICND Engineering
enneth M. Duffus, P.E.
Attachments: On -Site Sewer Application
Wastewater Absorption System Details/Site Plan
Soils Log/Percolation Test
WELL & WASTEWATER DISPOSAL SYSTEM DETAILS/SITE
GLENN VIEW ESTATES WEST S/D, LOT 20, BLOCK 2
NO PUBIC YELLS VITHIN COY IT
PROPOSED SYSTEM.
MO PRIVATE WELLS VITHIN LW' DE
PROPOSED SYSTEM EXCEPT AS NITER
NO SEPTIC- SYSTEMS VITHIN 200' OF
PROPOSED YELL EXCEPT AS NOTED.
Lot 22
Lot 21 1,It
VACANT
CUM MUCK(
PLAN
Lot '
Lot 20
/ X911
* ; • IH ....\ *#
VACANT
Lot 19
Lot
DESIG IETAILS
4 BDRM X 150 GPD = 600 GPD
600 GPO/0.8 GPD PER SO. FT. (4.21 MIN/IN.)= 750 SO. FT
(750/5'(V)) X .50(RF) (4.0' GRAVEL) = 75.0 FT. TRENCH
USE 1 TRENCH - 75 (L) X 5' (V) X 4.0'(D)
Total depth of system Is 7.0' from original grade.
Total depth of gravel below distribution pipe Is 4.0' .
NOTES:
1. USE 1250 GAL. SEPTIC TANK. INSULATE IF <4' OF COVER.
2. INSULATE TRENCH WITH 2' HD BURIAL FOAM.
3. CONTRACTOR VILL ENSURE MINIMUM 27. SLOPE INTO SEPTIC TANK.
4. ADDITIONAL FILL WILL BE ADDED OVER SYSTEM TO ACHIEVE
MIN. 3' COVER IF REQUIRED.
5. CONTRACTOR WILL ENSURE ALL SEPARATIONS TO ADJACENT
WELLS 6 SEPTICS.
PREPARED FOR:
TURNER CONSTRUCTION
PO BOX 3489
PALMER, AK 99645
(907) 745-8334
Scale: 1'= 100'
PAGE 1 OF 2
KENNET DUFF
CE -7116 /
C
AIbFYgg10NA�
DDPOART' LANG
Ita14 LANG
CE•sPUTEEt
DRAIN:
acorn: KMD
ASe'n° LANG
Owl FAL
DATL 4/18/01
END ENGINEERING
20441 PTARMIGAN BLVD.
EAGLE RIVER. AK 99577-8736
o-. NW1459
ACRD at' 010026.DWGNa: 010026
(907)898-8111/FAX (907)698-8111
WASTEWATER DISPOSAL SYSTEM DETAILS
GLENN VIEW ESTATES WEST S/D, LOT 20, BLOCK 2
ELE(
KND
fJ
PROPOSED
SYSTEM
TH#KN
SED PRIMARY
M
FCO
POSED 1250 GAL/
PTIC TANK
KENNETH M. DUFF
CE -7116
‘,.neorEssioloir
0
n
MT
CO
FOR:
TURNER CONSTRUCTION
PO BOX 3489
PALMER, AK 99645
C907) 745-8334
Scnle 1'= 20'
PAGE 2 OF 2
I1ELD BOOKS
coynurzu
n ' s" LANG
o"".,: VBG
"'SC LANG
CHEaCtil KIM
"a"% LANC
o ra nc:
o"'c: 4/18/01
END ENGINEERING
20441 PTARMIGAN BLVD.
EAGLE RIVER, AK 99577-8736
°aQ NW1459
"c"0' 010026.DWG'108 "" 010026
(907)696-6111/FAX (907)696-8111
•
JKbV D ENGINEERING
20441 PTARMIGAN BLVD.
EAGLE RIVER, AK 99577-8736
OrAlpb;••..... ;..............
.• rq .•' 9 �B
Litt * ?49111 •• *• II floe
�0
SOILS PERCOLATION TEST
Performed fon Arctic Devco
Project:
Depth
(Feet)
1
1
Lot 20, Block 2, Glenn View West
TEST HOLE 41 99-2/20
ORG — brown
SM — red brown/black
SM/GM —mostly SM w/gravel,
loose/med. density on top
increasing density w/depth
t:
HOLE PRESOAKED
20- PRIOR TO TEST
SEE ATTACHED SITE PLAN
FOR HOLE LOCATION
Was Ground water encountered? NO
Depth to water after monitoring? NO
What depth? NA
Date? 05/15/99
Reading
Date
Gross
Time
Net
Time
Depth to
Water
Net
Drop
1
4/21/99
2:40-
6"
-
2
2:50
IO min
32/16"
214/16"
3•
251
-
6"
-
4
3:01
10 min
35/16"
211/16"
5
•
3:02
-
6"
-
6
3:12
10 min
3 6/16"
210/16"
7
•
3:13
-
6"
-
8
323
IO min
310/16"
26/16"
9•
324
-
6"
-
10
3:34
10 min
310/16"
26/16"
11
•
3:35
-
6"
-
12
3:45
10 min
310/16"
26/16"
•
Water
Added
Percolation Rate 4.71 , (min/in) Perc Hole Diameter 6"
Test Run Between 3 feet and 4 feet
I, Kenneth M. Duffus, certify that this test was performed in accordance with all State and Municipal guidelines in
effect on this date.
•
• 6 N B 4
-: Municipality of Anchorage " `4a
On-Site Water and Wastewater Program `,>®,ii®i "
(907) 343-7904 s. r< ,, ,
Certificate of On-Site Systems Approval
Parcel W. 051 -793-37 Expiration Date: / Q -.‘2 7i'7
1. GENERAL INFORMATION
Complete legal description Lot 20, Bk 2 , Glenn View Estates West, Phase 2
Location (site address) 21304 Polly Circle, Chugiak, AK 99567
Current Property owner(s) Charlie & Kathryn Martin Day phone(907) 240-3780
Mailing address 21304 Polly Circle, Chugiak, AK 99567
Real Estate Agent Audrey Mason/RE/Max of ER Day phone(907) 622-3344
19 9 70 77
2. TYPE OF DWELLING: u� 4)n 0 k,.,1 :, ,off
U Single Family (w/wo ADU) _M
❑ Duplex 212017
❑ Multiple Dwellings (Single Family and/or Duplex)
.1.4 1� )0ti
3. NUMBER OF BEDROOMS: 3 t->4 a6 8 ,;
w
4. TYPE OF WATER SUPPLY: TYPE OF WASTEWATER DISPOSAL:
Individual Well E Individual IE
Individual Water Storage ❑ Holding Tank ❑
Community Class Well ❑ Community ❑
Public Water System ® Public Sewer ❑
WaiverNariance request for: Distance:
i I)
Received by: 1----- —y-1-- --- Date: 1(z((
COSA to be released to the engineer,unless otherwise requested by the engineer. L
COSA Fee $ 42-4:, - Waiver Fee $
Date of Payment 112.1 I ti Lk 13\4 Date of Payment
Receipt Number 2t 42 Receipt Number
COSA# 05C11131\ Waiver#
5. STATEMENT OF INSPECTION BY ENGINEER
As certified by my seal affixed hereto and as of the validation date shown below, I verify that my investigation,
based on procedures outlined in the Certificate of On-Site Systems Approval Guidelines for this application,
shows that the on-site water supply and/or wastewater disposal system is (are) safe, functional and adequate
for the number of bedrooms and type of structure indicated herein. I further verify that based on the information
obtained from the Municipality of Anchorage files and from my investigation and inspection, the on-site water
supply and/or wastewater disposal system is(are) in compliance with all applicable Municipal and State codes,
ordinances, and regulations in effect at the time of installation.
Name of Firm Pinard. Engineering Phone (907) 232-1347
Address PO Box 871347, Wasilla, AK 99687_
Engineer's Printed Name Paul E. Pinard Date 7/20/17
f�jOF Ad��
r.
.•
6. DSD SIGNATURE � ,r tFl �'\ •�;� e
hl
tiK System#1 Approved for 3 bedrooms r :,,,.. 1 k------.-•' k4
System#2 Approved for bedrooms Si
�.c, Paul . Pinard���
%...11;.# GT.' .4793 .:G• 0
Disapproved a*k.Y„tsoasea �'l�at��
e"q?�'�¢� �t\tYk.�I p I
Conditional approval for bedrooms, with the following stipulations 4i`"oftt fr '.
\CJAP N�,I t i r.
%QST �qi�Q
?3 li 'TOG yvA rcl?
-,� �'Al�,°� ,c
"_
------ ,(j
B.. .
�_ Original Certificate Date: 77_ I�
The Municipality of Anchorage Development Services Division (DSD) issues Certificates of On-Site Systems Approval (COSA) based only
upon the representations given in paragraph 5 by an independent professional civil engineer registered in the State of Alaska. The Municipality
of Anchorage is not responsible for errors or omissions in the professional engineers work.
7. ATTACHMENTS:
COSA Checklist X Nitrate Advisory
Septic System Advisory Arsenic Advisory
Well Flow Advisory Other
COSA blue sheet_f c
•
If more than 1 septic system is on the lot:
COSA Checklist# of
Structure served by this system
Certificate of On Site Systems Approval Checklist
Legal Description: Lot 20, Bk 2, Glenn View Estates West2 Parcel ID: 051 -793-37
A. WELL DATA NA - Public Water System
Well type If A, B, or C provide PWSID# Well Log (YIN)
Date completed Sanitary seal (Y/N) Wires properly protected (Y/N)
Total depth ft. Cased to ft. Casing height (above ground) in.
FROM WELL LOG AT INSPECTION
Date of test
Static water level ft. ft.
Well production g.p.m. g.p.m.
WATER SAMPLE RESULTS:
Coliform colonies/100 mL Nitrate mg/L
Arsenic ug/L Date of sample: Collected by:
B. SEPTIC/HOLDING TANK DATA
Tank Type/Material Septic/Steel Date installed 4/27/01
Tank size 1250 gal. Number of Compartments 2 Cleanouts (Y/N) Y
Foundation cleanout (Y/N) Y Depression over tank (Y/N) N High water alarm (Y/N) N
Date of pumping 8/23/16 Pumper JRs Pumpi n8
C. ABSORPTION FIELD DATA
4/28/010.8
Date installed 7/19/n Soil rating (g.p.d./ft2 antatintritS 0 7 System type 5 WideSha L low
Trench
Length 100 ft. Width 2 5 ft. Gravel below pipe 3 ft.
Total deptl- 2 7ft. Eff. absorption area 862 ftft2 Monitoring tube Y Depression over field N
Date of adequacy test 7/1 '7/1 7 Results (Pass/Fail) Pass For 3 bedrooms
Fluid depth in absorption field before test 12 in. Water added 600 gal. New depth 19 in.
Elapsed Time: 1 280 min. Final fluid depth 1 3 in. Absorption rate >= 450 g.p.d_
Any rejuvenation treatment (past 12 ma.) (Y/N &type) No If yes, give date
D. LIFT STATION NA
Date installed Size in gallons Manhole/Access (Y/N)
"Pump on" level at in. "Pump off" level at in. High water alarm level at in.
Datum Cycles tested Meets alarm&circuit requirements?
E. SEPARATION DISTANCES
WELL ON LOT TO: NA
Septic tank/lift station on lot On adjacent lots
Absorption field on lot On adjacent lots
Public sewer main Public sewer manhole/cleanout
Sewer/septic service line Holding tank
Animal containment areas Manure/animal excrete storage areas
SEPTIC/HOLDING TANK ON LOT TO:
Building foundation 5 ' + Property line 5 ' + Absorption field 5 ' +
Water main 101 + Water service line 10' + Surface water 100' +
Wells on adjacent lots 200' +
ABSORPTION FIELD ON LOT TO:
Property line 101 + Building foundation 101 + Water main 101+
Water Service line 101 + Surface water 1001 + Driveway, parking/vehicle storage 20 t+
Curtain drain None Known Wells on adjacent lots200'+
F. COMMENTS
The adequacy test was performed on the newest of the 5 Wide Shallow
Trenches. The other, older 5 Wide is shut off with a Diverter Valve .
This home is being sold as a 3 bedroom, single family residence .
G. ENGINEER'S CERTIFICATION
f1��E OF At
I certify that / have determined through field inspections and 1 A ,..•""•. 5 .
review of Municipal records that the above systems are in � co••. ,
conformance with MOA COSA guidelines in effect on this date. Nit i* { ttt'_ *.,*8
Engineer's Printed Name Paul E. Pinard s • .�� Vd Z�''`
Date 7/20/17 `�;�Paul E. Pinard+u ,
•
��� •. Cir -4793 .• -S
wleg#i,E�l��l►<<1
--�l l -1
COSA yellow sheet_2-6-15.doc
410 1.-",
Municipality of Anchorage
Development Services Department
Building Safety Division
On -Site Water & Wastewater Program
4700 Bragaw Street
P.O. Box 196650
Anchorage, AK 99519-6650
www.muni.orglonsite
(907) 343-7904
CERTIFICATE OF ON-SITE SYSTEMS APPROVAL
FOR A SINGLE FAMILY DWELLING
Parcel I.D. 057- 793-W-
1.
93-W-
1. GENERAL INFORMATION
Complete Legal description
Location (site address)
Current Property owner(s)
Mailing address
Lending agency
Mailing address
Real Estate Agent
Mailing address
COSA# (031'
Expiration Date. R -.2-q- 0 7
GLENN VIEW EST. W. PH 2; LOT 20, BLOCK 2
21304 POLLY CIRCLE • ANCHORAGE, AK 99567
JOHN BOBICH
Day phone
21304 POLLY CIRCLE • ANCHORAGE, AK 99567
Day phone
317-3228
DONNA ALDERMAN w/ PRUDENTIAL Day phone 3600158
16635 CENTERFIELD DRIVE • EAGLE RIVER, AK 99577
Unless otherwise requested, COSA will be held by DSD for pickup.
2. NUMBER OF BEDROOMS:
3. TYPE OF WATER SUPPLY:
Individual Well
Individual Water Storage
Community Class Well
Public Water System
4
TYPE OF WASTEWATER DISPOSAL:
❑ Individual On-site
❑ Individual Holding tank
❑ Community On-site
• Public Sewer
Tt1a-Mcmtelpality-6fAnchorage-DevetopmentServlces-Department jDSO)-Issues-Certificates-ofOn Site -Systems
Approval (COSA) based only upon the representations given In paragraph 4 by an independent professional civil
engineer registered in the State of Alaska. Certificates of On -Site Systems Approval are required for the transfer
of title (except between spouses) for properties served by a single-family on-site wastewater disposa and/or
water supply system. DSD also issues COSAS upon request to homeowners. Certificates of On -Site Systems
Approval are valid for 90 days from the date of issue for properties served by a private or Class C well and may
be reissued with new water samples. (Certificates may be reissued for a period of up to one year with valid water
samples.) Certificates are valid for one year for properties served by Class A or B wells or a public water system.
The Municipality of Anchorage is not responsible for errors or omissions in the professional engineer's work.
4. STATEMENT OF INSPECTION BY ENGINEER
As certified by my seal affixed hereto and as of the validation date shown below, 1 verify that my
investigation, based on procedures outlined in the Certificate of On -Site Systems Approval Guidelines for this application,
shows that the on-site water supply and/or wastewater disposal system is (are) safe, functional and adequate
for the number of bedrooms and type of structure indicated herein. I further verify that based on the
information obtained from the Municipality of Anchorage files and from my investigation and inspection, the
on-site water supply and/or wastewater disposal system is(are) in compliance with all applicable Municipal
and State codes, ordinances, and regulations in effect at the time of installation.
Name of Firm GARNESS ENGINEERING GROUP. Ltd.
Address
3701 E. TUDOR ROAD, SUITE 101 • ANCHORAGE. AK 99507
Engineer's Printed Name JEFFREY A. GARNESS, P.E.
Engineer's Comments:
In conducting this evaluation, GEG, LtD. attempted to provide a thorough,
conscientious engineering analysis of the system In accordance with ADEC and MOA
DSD Guidelines & Regulations. The reported results described the performance of the
system under the conditions encountered at the time of the test, and separation
distances measured to readily Identifiable features. The operational life of all wells and
septic systems depend on the local soils condition, groundwater levels that may
fluctuate during the year, and the water usage of the family being served by the system.
These conditions are outside the control of the evaluator of the system. Satisfactory test
results do not guarantee future performance of the system, nor do they guarantee that
there are no hidden defects or encroachments. GEG, LTD. can therefore not provide
any warranty or future estimate of how long the system will continue to meet the
operational requirements of the ADEC or MOA DSD. The content of this report Is for
the solo benefit of the owner listed above. Any reliance upon or use of this report by any
other person a party Is not authorized, nor will It confer any legal right whatsoever.
Phone 337-6179
Date
8bola
5. DSD SIGNATURE
Approved for bedrooms.
Disapproved.
Conditional approval for bedrooms, with the filowing stipulations:
Attachments:
rOSA_Checldst t/ O '••• •••.
Arsenic -Advisory
.`�,v`�P�`�YtOF glN06,
tee: tr
; ON -TTL c
`�; WATER AND : °1=
WASTEWATER : _
e. PROGRAM
Septic System Advisory
Well Flow Advisory
Nitrate Advisory
Maintenance Agreements
Supplemental Engineer's Reort
Other
IR.. 11.1151
Original Certificate Date' g " a q —o G
Municipality of Anchorage
Development Services Department
Building Safety Division
On -Site Water & Wastewater Program
4700 Bragaw Street
P.O. Box 196650
Anchorage. AK 99519-6850
www.muni.arg/onsite
(907)343-7904
CERTIFICATE OF ON-SITE SYSTEMS APPROVAL CHECKLIST
Legal Description. GLENN VIEW EST. W. PH 2; LOT 20, BLOCK 2 Parcel 10:05'/- 793-37
A. WELL DATA
Web typePte_ If A, 6, or C provide PWSID# _ Well L
Date completed Sanitary seal i. Wires party peed (YIN)
Cased to ft. Casing height (above ground) in.
FROM WELL LOG AT INSPECTION
Date of test
Static water level
Well production
WATER SAMPLE RESULTS:
ft.
El p.m.
ft.
g.p.m.
Coliform colonies/100 ml. Nitrate �� • •'i -r bacteria colonies/100 ml.
Arseni .. . Date of sample: Collected by:
B. SEPTIC/HOLDING TANK DATA
Tank Type/Material
Tank size 1250 gal Number of Compartments 2 Cleanouts (Y/N) TES
SEPTIC/STEEL
Date installed
4/27/2001
Foundation deanout (Y/N) YES Depression over tank (WN) NO
Date of pumping 6/28/2006
C. ABSORPTION FIELD DATA SHALLOW TRENCH
4/28/2001 0.8
Date installed 7/18-19/2006 Soil rating •.p.d 'r •r fL bdrm) 0_7 System type S WIDE
82 5 4 ft
Length 100 ft Width 5 ft. Gravel below pipe
7 820 YES Depression over field NO
Total depth e•2r7•oaft. ER. absorption area 862 re Monitoring tuba pre
Date of adequacy test NEW Results (Pass/Fail) PASS For 4 bedrooms
Pumper
High water alarm (Y/N) N/A
SANITARY PUMPERS
;:14.11 aNiAd&teli0C3
Fluid depth in absorption field before test = in Water added - gal
New depth =in.
Elapsed Time: - min. Final fluid depth = in Absorption rate x 600+ g.p d
Any rejuvenation treatment (past 12 mo.) (YIN & type)
NONE KNOWN
If yes, give date
D. UFT STATION
Date installed Size in gallons Manhole/Access (Y/N)
Pump on" level at _in. -Pump off' leve : — . • igh water alarm level at
Cycles tested
E. SEPARATION DISTANCES
SEPARATION DISTANCES FROM WELL ON LOT TO:
Septic tank/Uft station on lot
Absorption field on lot
Public sewer main
in.
Meets mann & circuit requirements?
PUBLIC WATER
On adjacent lots
On adjace
ublIc sewer manhole/deanout
Sewer /septic service line Holding tank
Ani lnment areas Manure/animal excrete storage areas
SEPARATION DISTANCES FROM SEPTIC/HOLDING TANK ON LOT TO:
Building foundation
5'+
Property line 5'+ Absorption field 5'+
Water main 10'+ Water service line 10'+ Surface water 100'+
Wells on adjacent Tots 200'+
SEPARATION DISTANCE FROM ABSORPTION FIELD ON LOT TO:
Property line 10'+ Building foundation 10'+ Water main N/A
Water service line 10'+ Surface water 100'+ Driveway, parldng/vehide storage 10'+
Curtain drain NONE KNOWN Wells on adjacent lots 200'+
F. COMMENTS
G. ENGINEER'S CERTIFICATION
1 certify that 1 have detemwned through field inspections and
review of Municipal records that the above systems are in
conformance with MOA COSA guidelines in etfed on this
date.
Engineer's Printed Name JEFFREY A. GARNESS
Date 8 Isola.
COSA Fee $ -*Ts--,7/ � Waiver Fee $
Date of Payment 2/] / /06 Date of Payment
Receipt Number /60100, Receipt Number
(Rev. 11/05)
(n
co
P
2.5' X 7.9' CANT
1 1""
to 25.1'
26.5 O
M
11.o' x 8.6' CANT in v N W000 FORAME RY 14.5'
M o M RESIDENCE in
/11111/11
2.0' X 4.7' CANT
i
14.0'
2.0' ;n
25.9' 25.1' .111\ o' X 5.7' CANT
HOUSE DETAIL
10-30'
PORCH
Lot 21
S 89•51'021‘v 300.00'
30.00'
15' TELECOM. &
ELECT. EASEMENT
EATLAALm
z
SEPTIC CLEAN -OUTS
19.7' X 12.3' SHED
Lot 20
40,100 s.f.
209.8'
4.6'X8.6'SHED
S 86'42 35 E 280.60
Lot 19
NOTE: THIS PROPERTY 15 SERVED BY A PUBLJC WATER SYSTEM.
PLOT PLAN _ AS BUILT X SCALE 1e — 50' GRID
5.
77378;777"S
'ASPHALTS
DRIVEW,AY,=
t..
L-32 I17'
R-50.00'
L-29'1/
R-50.00'
m
rn
u
u
NW 1459 ProJeat No. 06-159
310810 Al10d
Lang•
& Associates Inc. 11500 Daryl Avenue, Anchorage.
, 907) 522-6476 Phone
Registered Land Surveyors (907) 522-4625 Fax
kglanglsOalaska.net / JelanglsOalaska.nst
I hereby certify that 1 have surveyed the following described props
LOT 20, BLOCK 2, GLENN VIEW WEST SUBDIVISION, PHASE No. 2 (PLAT 2000-89)
Anchorage Recording District, Alaska, and that the Improvements situated thereon are
within the property Tines and do not encroach onto the property adjacent thereto, that
no Improvements on the property lying adjacent thereto encroach on the surveyed
premises and that there are no roadways, transmission Tines or other visible
easements on said property except as Indicated hereon.
Dated this the 1 Day of h'-1 r itt4'[ , Zmf° , at Anchorage, Alaska
M Is the responsibility of the owner to determine the existence of any easements,
covenants, or restrictions which do not appear on the recorded subdMsion plat.
Alaska 99515-3049
Municipality of Anchorage
Development Services Department
Building Safety Division
On -Site Water and Wastewater Program
4700 South Bragaw St.
P.O. Box 196650 Anchorage, AK 99519-8650
www.muni.orglonsite
(907) 343-7904
ON-SITE SEWER/WELL SUBMITTAL COMMENT SHEET
To: Jeff harness
Legal description: Glen View Estates West Phase 2 Block 2 Lot 20
The attached paperwork has been reviewed and is being returned for the following reasons:
❑ Original signature or stamp missing on
❑ Calculation error in design.
❑ Additional soils information needed.
❑ Water monitoring results inadequate.
❑ Discrepancy In information submitted. _
❑ Topographic information missing or inadequate. r..�,�3
® Incomplete; missing Test Holes on Inspection Report. S ti & J's.. -41/4 a
® Incomplete; missing 0.6 soils and 1000 square feet proposed on permit only 862 ssqs�are
feet installed. No confirmation test hole submitted.— fc(643 on i/W'f mak_
e .)sc.0.1 p 1:...-liq (�w�c. AISoco".
❑ Additional adequacy test information needed. i-t-st A< J,A . on) .y. +.sal•),
Water sample unacceptable. .}1,.vt-4..c,,.,NS'SeS �r.y.cN
❑ Measured/proposed distances/dimensions missing.
❑ Locations of all soils, percolation and water monitoring tests not shown.
❑ Proposed system too deep for soils information submitted.
❑ Well log required.
❑ Omission in narrative.
❑ Insufficient fill over tank or field._
® Other. ___
Name of reviewer: Poet Date: 8-21-06
Please supply the necessary information and re -submit your request.
LEAVE THIS FORM ATTACHED TO THE PAPERWORK
Municipality of Anchorage
Development Services Department
Building Safety Division
On -Site Water and Wastewater Program
4700 South Bragaw St.
P.O. Box 196650 Anchorage, AK 99519-6650
www.ci.anchorage.ak.us
(907) 343-7904
CERTIFICATE OF HEALTH AUTHORITY APPROVAL
FOR A SINGLE FAMILY DWELLING
Parcel I.D. 051-793-37
1.
HAA# HA O /a G 9 7
Expiration Date: / 2 - (`1- 0.2 -
GENERAL INFORMATION
Complete legal description c Glenn View West Esates Phase 2. Block 2. Lot 20
Location (site address or directions)
Current Property owner(s) Turner Construction Day phone
Mailing address PO Box 3489 Palmer. AK. 99645
Lending agency
Mailing address
Real Estate Agent
Day phone
Gary Gearhart - Prudential -Vista Day phone 242-3294
Mailing Address 16635 Centerfield Dr.. Eagle River. AK 99577
Unless otherwise requested, HAA will be held by DSD for pickup.
2. NUMBER OF BEDROOMS:
3. TYPE OF WATER SUPPLY:
Individual Well
Individual Water Storage
Community Class Well
Public Water System
4
TYPE OF WASTEWATER DISPOSAL:
❑ Individual On-site
O Individual Holding tank
O Community On-site
Public Sewer
The Municipality of Anchorage Development Services Department (DSD) Issues Certificates .of Health Authority
Approval (HAA) based only upon the representations given in paragraph 5 by an independent professional
civil engineer registered in the State of Alaska. Certificates of Health Authority Approval are required for the
transfer of title (except between spouses) for properties served by a single family on-site wastewater disposal
and/or water supply system. DSD also issues HAAs upon request to homeowners. Certificates of Health
Authority Approval are valid for 90 days from the date of issue for properties served by a private or Class C well
and may be reissued with new water sample results less than 30 days old. (Certificates may be reissued for a
period of up to one year with valid water samples.) Certificates are valid for one year for properties served by
Class A or B wells or a public water system. The Municipality of Anchorage is not responsible for errors or
omissions in the professional engineer's work.
4. STATEMENT OF INSPECTION BY ENGINEER
As certified by my seal affixed hereto and as of the validation date shown below, I verify that my
investigation, based on procedures outlined In the Health Authority Approval Guidelines for this
application, shows that the on-site water supply and/or wastewater disposal system is(are) safe, functional
and adequate for the number of bedrooms and type of structure indicated herein. I further verify that
based on the information obtained from the Municipality of Anchorage files and from my investigation and
inspection, the on-site water supply and/or wastewater disposal system is(are) in compliance with all
applicable Municipal and State codes, ordinances, and regulations in effect at the time of installation.
Name of Firm KND Engineering
Address 20441 Ptarmigan Blvd. Eagle River, AK. 99577
Engineer's Printed Name Kenneth M. Duffus
Phone 696-6111
Date 12/18/01
0 Ataapa4
,Cresp
B ,,Tm Ci e•••C. ,pe NEER S
F.
5. DSD SIGNATURE v r, • Kenr,C 11 ;i. •'
C •,• a7115 b.i.�
Approved for bedrooms.
44, St.
'he ''•••.....••';'�`�a.„"�
Disapproved. aa(i%a1��-�'b
Conditional approval for bedrooms, with the following stipulations:
ttt11
kkFJ�Y OFagrt_ ,;.
Additional Comments
SS : ON-SITE •t t'
WATFR AND ' in
WASTEWATER :
e. PROGRAM •
o'
�i t( ...,,)pcy�;
€wr .'`N71\\��
Attachments:
HAA Checklist X
Septic System Advisory
Well Flow Advisory
By: 0� � Id .
/
(Rev. 12/00)
Maintenance Agreements
Supplemental Engineer's Report
Other
Original Certificate Date: / L , / '7- O %
Legal Description'
Municipality of Anchorage
Development Services Department
Building Safety Division
On-SIte Water & Wastewater Program
4700 South Bragaw St.
P.O. Box 196650 Anchorage, AK 99519-6650
www.ci.anchorage.ak.us
(907) 343-7904
HEALTH AUTHORITY APPROVAL CHECKLIST
Glenn View West Estates Phase 2. Block 2. Lot 20 Parcel ID: 051.79337
A. WELL DATA
Well type PUBLIC
Date completed
Total depth fL
If A, 13, or C provide PWSID #
Sanitary seal (YM)
Cased to ft.
FROM WELL LOG
Date of test
Static water level ft.
Wen production g.p.m
WATER SAMPLE RESULTS:
Coliform colonies/100 ml. Nitrate mg./1.
Well Log (Y/N)
Wires properly protected (Y/N)
Casing height (above ground)
AT INSPECTION
ft.
g.p.m.
Other bacteria colonies/100m1
Date of sample: Collected by:
B. SEPTICMOLDING TANK DATA
Tank Type/Material Anch. Tank! steel
Date installed 4127101 Tank size 1250 gal. Number of Compartments 2
Cleanouts Y.Foundation cleanout Depression over tank 0_Hlgh water alarm's
Date of pumping na-new tank Pumper
C. ABSORPTION FIELD DATA
Date installed 4128101 Soil rating (g.p.dift2 or ft2/bdrm) System type shallow trench
Length $t_ ft. Width 5 ft. Gravel below pipe 4.09 ft.
Total depth L ft. Eft. absorption area 820 ft' Monitoring tube y. Depression over field n•
Date of adequacy test Daenew system Results (Pass/Fail) sass For i bedrooms
Fluid depth in absorption field before test _ in. Water added_ gal. New depth_ in.
Elapsed Time: _ min. Final fluid depth _ in.
Absorption rate >= g.p.d.
Any rejuvenation treatment (past 12 mo.) (Y/N & type) If yes, give date
D. UFT STATION
Date installed na
Size in gallons
Manhole/Access (Y/N)
'Pump on" level at _ in. 'Pump off' at _ In.High water alarm level at
Datum Cycles tested Meets alarm & circuit requirements?
E. SEPARATION DISTANCES
SEPARATION DISTANCES FROM WELL ON LOT TO:
Septic tank/lift station on lot On adjacent lots
Absorption field on lot On adjacent Tots
Public sewer main Public sewer manhole/cleanout
Sewer /septic service line Holding tank
SEPARATION DISTANCES FROM SEPTIC/HOLDING TANK ON LOT TO:
Building foundation 5'. Property Zine 'LF Absorption field 5'+
in.
Water main 10'.
Water service line 10'+ Surface water 100'+
Wells on adjacent Tots 200'.
SEPARATION DISTANCE FROM ABSORPTION FIELD ON LOT TO:
Property line 10'. Building foundation 10'+
Water main 10'.
Water Service line 10'+ Surface water 100'+ Driveway, parkinglvehicle storage '+
Curtain drain 50'+ Wells on adjacent lots 200'+ _
F. COMMENTS
G. ENGINEER'S CERTIFICATION
I certify that I have determined through held inspections and
review of Municipal records that the above systems are in
conformance with MOA HAA guidelines in effect on this date.
Engineer's Printed Name Kenneth M. Duffus
Date 12118101
i� Keine h N.. W6.•. f /
N G I t -ii i4 S
\\_ rO ESSICn
HAA Fee $300
Date of Payment 12/18/01
Receipt Number !?ji M
(Rev. 12/00)
Waiver Fee $
Date of Payment
Receipt Number