Onsite Wastewater Disposal System and/or Well Inspection Report
Permit Number. SWO10065 PID Number. 017-113-13
Name: JEFF HENDRIKSON
Wastewater System: ■ New ❑ Upgrade
6171 ROSEWOOD DRIVE a ANCHORAGE. AK 99518
ABSORPTION FIELD
Phone. No. of Bedrooms:
(907) 565-4799 5
Deep Trench O Shallow Trench Mound Bed O Mou■Other
o s
LEGAL DESCRIPTION
s" Ed`s 2.0 am/sq. FL
Depot
'`� 1.22 — 1 s3 R
Lot: Block: Subdivision:
Depth to pipe better, from 010 pose
pawl depth beneath plpe
11 1 FOREST RIDGE
0.52 - 1.23 n
0.70 r<
Township: Range: Section:
FIN tided c•rM^el P••e
o" wngtk
- - —
1.5 - 2.5 In.
40 rt
Gravel width;
NuMer of Fes
DYbnee b.t...n hese
WELL: ■ New ❑ Upgrade
10 rt
2
5 rt
CloeeMocoon Prwa* A&C
7otd Depth:
cooed 7.
Told absorption area:
Flee Iri.terlet
PRIVATE
1 73 n
73 rt
400+400 sm rt
D 3034/F-Bto/SCH 40 PVC
orwr:
Dot. priced:
store water Lew:
31
kw~.
DENALI SEWER & DRAIN
Dat. irrree.d:
6/7-13/01
ALPINE DRILLING
4/13/01
rt
nee:
wmp sd �
corny "eight #be" t:fa.ra
TANK
30 leu
UNKNOWN n
2 Ft.
SEPARATION
DISTANCES
;Septic ;Holding ■S.TZP. 0Other
To
Septic
Absorption
Uft
Holding
blk/Prlyd.
MVMi1ac0"r`
ANCHORAGE TANK
Cevedb in 9.cww
2000
From
Tank
Field
Station
Tank
sew tk+w
Well
100'+
100'+
100'+
—
25'+
tbma. STEEL
le.ne. of ownpan•w� 2
Surface water
100'+
100'+
100'+
—
—
LIFT STATION
Lot Line
5'+
10'+
5'+
-
-
lialwon
su.2000
Cox
NK ORENCO SYSTEMS
ANCHORAGE T
Foundation
5'+
10'+
5'+
-
-
m teed at:
TIMER
level eb
TIMER
mlin wet. dam -
45e
rasp a Yodat
eectrlor enpfem
••aon. perred W.
Curtain Drain
NONE
KNOW
RE
ORENCmo
M.O.A.
Remarks: 'THIS IS AN ADVANTEX TREATMENT SYSTEM.
BENCH MARK
latatbe and Description
BOTH PRIMARY AND ALTERNATE SITES WERE INSTALLED
GARAGE FLOOR SLAB ON SOUTH SIDE.
PER THE REQUEST OF THE HOMEOWNER.
Dense ".orae 101.04 n
ENGINEERS ll N
"QOF �4°oou
Inspections performed by: AWWC, INC. Dates: list 6/7/01
*�... .... ...... °
2nd -4th 6/13/01
5th 8/27/01
:ere M .ss:..
OQ
Department of Health and an Servic s approval
4�� •.• 7953
Ree �ievved and approved by: Date:1:2-17-0I
n
DOpOPr resa10�
0
4000
PERMIT NUAS-BUILT DRAWING PNUMBER:
SW010065 065 -017 017-11 13-13
TH# /
I
I '
NEW 2000 GALLON
RECIRCULATING SEPTIC
TANK (ADVANTEX)
0
I
B
I 51 \ INSTALLED
H� DIVERTER VALY
I ,
MH 3 s NEW DRAII
do
/ZSEPTI'C
sE TE
NOTE: BOTH PRIMARY
AND ALTERNATE SITES
WERE INSTALLED PER
HE REQUEST OF THE
HOMEOWNER.
NEW WELL
11/30/2001
F,grZ� , oNnwN er:
4.
ALASKA WATER &. WASTEWATER c.J.c.
CONSULTANTS, INC.
wool ncoeoo cnen tl.TF 7N . AW.nFeOF eR *Q1M • R F (0071117(110 • FAX (907MAA.1746
PREPARM FOR: PHONE NUMBER: jrnL NUMB
JEFF HENDRIKSON (907) 565-4799 1 2 OF 3
FOREST RIDGE SUBDIVISION: LOT 11, BLOCK 1
AS -BUILT DRAWING OF NEW WELL AND SEPTIC SYSTEM
rn 93;
E 7953 `F
............ c�Qv
A
8
ST1
17.6
33.8
MH1
24.5
34.7
MH2
28.8
39.4
DV
33.4
36.9
MT1
31.4
25.1
MT2
31.9
25.1
MT3
37.2
43.1
MT4
41.8
50.4
MT5
69.3
58.5
MT6
.8
61.8
MT7
E772.5
68.9
MT8
75.5
73.8
rn 93;
E 7953 `F
............ c�Qv
PERMrrNUMBER: AS -BUILT DRAWING PARCEL- NUMBER:
SW010065 017-113-13
SWO
MOM -91J0* r-fOF OF MAwaf TOP OF HAMA
- 99.05 9915
iK'MIG FLIER I/
PODS
Gp OF fAIK
At Olnff -"JO
51 h'H
fCP OF IAll:
Af NEf -95.8
;
NSW 2000 GAI.I.ON
O
U a 5S.E.P. TANK
AINfI
avER(�a�
AfCLMff-963(s)
NTRfofV"
Af CUILEI.91"
EM
FINAL GRADE ORIGINAL GRADE ORIGINAL GRADE FINAL GRADE
99.0+ - 97.52-97.79 97.52-98.23 INSULATION 99.2+
NSULATION
Mf Mf
Q't
10.1 Q•
BOTTOM OF WMa OF BOTTOM OF
DILVNFIELD DISTRIBUTION LINES INVERT OF D2VNFIELD
-95.97 -96.7 (AVG.) DWMBUInON ONES (A 9V96.30
(AVERAGE)
- 97.00 (AVC.)RAD
DATE
11/30/2001
Qgo�40
0
d,`� •}�., f14�
DRAWN BY:
ALASKA WATER & WASTEWATER
C.J.G.
ago%' y p
SCALE
CONSULTANTS, INC
N.T.S..........
' "' ""' "''�
6001 DFRARR ROAD. SURF 79 • ANCNORAGF. AK 00504 PNONF (WI)3374179FAX (007)319.3766
PREPARED FOR: PHONE NUMBER:
PAGE NUMBER:
JEFF HENDRIKSON (907) 565-4799
3 OF 3
0
pp 953 .: 1
��4i^''• �qoo�
4��dPFofesslo�°V ��
LEGAL DESCRIPnON:
FOREST RIDGE SUBDIVISION; LOT 11, BLOCK 1,
TYPE OF WORK
DRAWING OF SEPTIC SYSTEM UPGRADE
PROFILE AS -BUILT
az, bt'zz lNsyEC:,FrON.j?Ed opr
'MUNICIPALITY OF ANCHORAGE—' BUILDING SAFETY DIVISION
4700 SOUTH BRACAV STREET, ANCHORAGE, ALASKA
i'
6PF.C770A5: Voice: (907) 343-8300 Far: (907)149-7777 ! INFORM471O11:• (907) 343-3211
�
MAM ALCAN ELE=, ,JC PERlfr1'ALTlBEl'.: 01 -93,45
' t.
WIDDtt£ss: 5201 BISHOPS CASTLE CIIt , :DATE: 11/1'2001
S PHONE 01: 351-6141: , PHOA2 0?:
A7: i 11 BLOCK. • 1 SUBDIPMION.• FORRLSTRllGE
9rrtfEA'IJ': GLE-,\7a T STAIION/PAPER FOLDED INELEC CABINET
4
FPE OFt+3: a3 #3.
LSPEC770N:
No non-compliance observed
Cotrcaioru csscndal as cxpla:ncd Wow.
�ararEn75:•
Do tn•t conceal until re -inspected. ❑ C.O. alq,rovcd.
1411 rc-exmr ne at nett ImTcai n. ❑ C.C.O. aplKovcd (corm at below).
M13 (Stonmwater) t
: r P.eim;pec9:rt? �i]
f
I '
i 1
I !%
-PEG70R: I } 1 + J DATE:
Stonrwxrr teannad plaa's;+a. •xt site. 0 Stwnwalcr trea:mmt irnpla r.mtrd. I
SitecM:t: dinat a Wnt4 b:ir.; a atro!led. ❑ bmtsalconca rrax bsles.
kr tal�Jcomcl silt farts. ❑ Mer best msm„rm:nt pmaices or s!te'need:d.
Sec a:tac,:ed derailed ootes _mmvirc. ❑ Falltxe to eo :p!y nmy reso!t in fires.
Take w--'= cow. ❑ peirapea!on will be m:dc or.: — --- I
❑ Redimallow. —
xt icer. to: Con:psry: I
ID7IENCORILF 77ONSAREMWE,PMLSECriLLFORINSPE(MON xe3
DO NOT REMOVF- THIS A'077CE.
,
-- eriL-0f H031th anri HUMan_SP"1CW
825 OV Street
- -—PO:8ex�9G669-Aasbera9s:Alacka9fl51 r -
Rick Mystrom t np'IMwN.d.w+cPaage.aicus
Mayor
Permit Number. *SW 010 Date of Issue: 4-13-01 Parcel Identification Number. 017-113-13
Date Started: 4-13-01 Date Completed: 4-13-01 Is well located at approved permit location'? Yes -O No
Legal Description:-.-.FugrestJ3idt7B Block llat 11
property owner Name & Addle+s: Jeffery D & Tanya Hennkson
..-5334 Bieheps4a6#e4kVk
AriMaraae. Ak 99516
Borehole Data:
Depth (ft)
Method of Drilling ® air rotary cable too]
Soil Type, Thickness & W�lerStrata
From To
Casing type: Sleet -
stick-up _
-0 1 .
Wald Thkjne.gr� inches _
2 9
Diameter: 6 inches Depth: 73 feet
organic & silt
Liner Type:
gravelly cobbly silt
9 67
'aches epi feet
water sand & gravel
67 73
-bier:
Casing stickup above ground: 2 feet
Static water level (from ground level): 31 feet
--Pumping1cveI-.M1eet g11er
4 hmirsVttmping3D+gpm
Recovery Rate: 30+ gpm
Method oUesBng: air_TM
-'Vtlettitrtsikkc-t3prntttg�{><:
.JZ Open End rJ Open Hole
❑ Screened Start feet Stopped feet
-0rerforatium -Start zfbct -Scarped met
-;rout Type: 9entonite�! 8 Volume: j rig
Depth:Start 0 feet Stopped ± feet
pimp: Intake Depth feet
' -Pomp Azc ftp Brand�ame
well Disisfected-uren-C-ot%P et "?4Z xca O 1J
Method of Disinfection: Clorine Tablets
Comments:
Well Driller. Alpine Drilling 8 Enterprises
P O Box 110496
Anchorage AK 99511
Attention: The well drillershaltprev9dea'vell d thepropcay
nu•rw nr flw wr{I
h:!.n
A,;1t, eh+1{ n�nvv{n s uwll Lr. to IM..n
rlt nr 14"Ith !Z limmln Cnnnroc ontn Aove nr rmm�lMinn
MUNICIPALITY OF ANCHORAGE 'f ,Q
Development Services Department Iil''r�.
On -Site Water 8 Wastewater Program
4700 South Bragaw Street
P.O. Box 196650, Anchorage, AK 99519-6650
(907) 343-7904
ONSITE WASTEWATER DISPOSAL SYSTEM / WATER SUPPLY PERMIT
Initial
L (.1,61a/
ZPM 1411)/
Date Issued: Apr 13, 2001
Expiration Date: Apr 13, 2002
Permit Number: SWO10065 Parcel ID: 017-113-13
Legal Description: 'FOREST RIDGE SUBDIVISION BLOCK 1 LOT 11 ,
Design Engineer: 0041 AK Water & Wastewater Consultant Site Address: 5331 BISHOPS CASTLE CIRCLE
Owner Name: JEFFERY D & TANYA L HENRIKSON Lot Size: 42806 SO. FT.
Owner Address: 5331 BISHOPS CASTLE CIRCLE Total Bedrooms: 5 Permit Bedrooms: 5
ANCHORAGE . AK 995164266
This permit is for the construction of:
Disposal Field Q✓ Septic Tank ❑ Holding Tank E] Privy Q✓ Private Well ❑ Water Storage
All construction must be in accordance with:
1. The attached approved design.
2. All requirements specified In Anchorage Municipal Code Chapters 15.55 and 15.65 and the State of Alaska
Wastewater Disposal Regulations (18AAC72 ) and Drinking Water Regulations (18AAC80 ).
3, The engineer must notify DSD at least 2 hours prior to each inspection. Provide notification by calling
(907) 343-7904 (24 hours). ( Not required for a Water Supply Permit only).
4. From October 15 to April 15, a subsurface soil absorption system under construction during freezing weather
must be either: A. Open and closed on the same day.
B. Covered, sealed, and heated to prevent freezing.
Received By:
Issued By:
Date: 4/-13-19/
Date: 4 — /3 —0/
Municipality of Anchorage
Development Services Department
Building Safely Division
OnSlte Water d Wastewater Program
4700 South Bragaw St
P.O. Boz 196650 Anchorage, AK 99519-6650
www.d.anchorege.akus
(907)343.7904
ON-SITE SEWER/WELL PERMIT APPLICATION
FOR A SINGLE FAMILY DWELLING
Parcel I.D. 017-//3-/3 Permit Number S1,/010065'
Property owneqs) JEFF HENfRIKSON Day phone 565-4799
Mailing address (1) 6171 ROSEWOOD DRIVE • ANCHORAGE. AK 995,18
:rm
Meilingaddress (2) 5331 8154WOPS CASTLE CIRCLE zip Code 995lprt-4ZK
Legal description (Section, Township & Range) N/A
Lot Size 42.806 AmWSq.FL Number of Bedrooms 5
THIS APPLICATION IS FOR:
Sewer Only ❑ Well Only ❑
Sewer and Well N Water Storage ❑
Sewer Upgrade ❑
THIS PROPERTY CONTAINS:
Hot Tub ❑ JacuzA ❑
Swimming Pool ❑ Water Softening Unit ❑
Therapy Pool ❑
I certify that the above information is correct. I further certify that this application is being made for a
Single Family Dwelling and is in accordance with applicable Municipal codes.
ALASKA WATER k WASTEWATER CONSULTANTS, INC.
(Signature of property eownef or au"Ared ageni)
Permit Fees: 5,1 i/yo • O O
Date of Payment: V-5-0/
Receipt Number. R5g(o
Waiver Fees*
Date of Payment:
Receipt Number.
ALASKA WATER & WASTEWATER
CONSULTANTS, INC.
April 2, 2001
Municipality of Anchorage
Development Service Department
Building Safety Division
On -Site Water & Wastewater Program
P.O. Box 196650
Anchorage, Alaska 99519-6650
Ref: Well and Septic Design for Lot 11, Block 1, Forest Ridge Subdivision
To whom it may concern:
The proposed 5 bedroom house will be served by a private well and septic system. Test holes
were excavated on the property. The proposed septic system will be designed around the 30 foot
radius of test hole #2. We are proposing that a 2000 gallon septic tank with the Advantex
Treatment System and a lift station; and a pressurized bed type drainfield be installed. Comments
regarding the proposed design are summarized as follows:
1. SOILS: Attached are logs which shows the soil classifications, groundwater monitoring, and
the percolation test results. It is our opinion that due to the overall appearance of the soils, an
application rate of 2.0 gallons/day/ft2 should be used for the Advantex treatment system.
2. PRESSURIZED BED DESIGN:
a. Percolation Rate: 20 minutes/inch
b. Allowable Application Rate: 2.0 gallons/day/ft2
c. Number of Bedrooms: 5
d. Design Flow: 750 gallons per day
e. Minimum Absorption Area: 375 ft2
f. Total Depth: 2 feet (maximum - at any point. remove all organics)
g. Leveling Sand: 0.5 to 1.0 feet
h. Effective Depth: 0.5 feet
1. Width: 10 feet
j. Minimum Length: 40 feet long
k. Effective absorption area = 400 ft2
Note: The distribution lines are to be 1-1/4 inch diameter schedule 40 pvc with 1/4 inch diameter
holes spaced every 30 inches on center. Each lateral is to be 38 feet long and have 15 holes per
lateral.
6901 Debarr Road, Suite 2B * Anchorage, AK 99504
Ph: (907) 337-6179 * Fax: (907) 338-3246 * Website: akwwc.com
3. SURFACE WATERS: There are no surface waters within 100 feet of the proposed septic
system.
4. TOPOGRAPHY: As can be seen on the attached topography site plan, the average
topography of this property is a 5+/- percent running from approximately east to west; in short,
there are no slope concerns. The trench is to be installed parallel to slope contours.
I am unaware of any adverse impacts this installation would have on adjacent wells or septic
systems. If you have any questions, please contact me at 337-6179, or 244-9612. Thank you
for your assistance.
P.E., M.S.
NOTE. Attached is a site planta wing, a design drawing, a detail drawing, a topography site
plan, two soils logs, and a �C page construction specification letter which are all part of the
design package for this septic system.
6901 Debarr Road, Suite 2B * Anchorage, AK 99504
Ph: (907) 337-6179 * Fax: (907) 338-3246 * Website: akwwc.com
BIRCH TREE ESTATES S/D( BIRCH TREE ESTATES S/D I BIRCH TREE ESTATES S/D I BIRCH TEE BETE S S/D
LOT 3LOT 35,2. BLOCK 1, LOT 33, BLOCK 1, LOT 34, BLOCK 1,
--------�-O-QDiWEN-AMUE-----------------------
---------------i
r------------
PROPOSED
FOREST RIDGE S/D I
1 5 BEDROOM
LOT 8. BLOCK 1,
HOUSE �-
I
1
EEppT�II
�AREAG I
I
D 1
I TH�t
i
I
I
PROPOSED SEPTIC SYSTEM -
(SEE DESIGN, PACE 2 OF 3)
100' WELL RADIUS
FOREST RIDGE S/D
LOT B, BLOCK
ki
FOREST RIDGE S/O
LOT 12, BLOCK 1,
•-1"FACANTD
f'�
M��
FOREST RIDGE S/D
LOT 4, BLOCK 1„ j
ALASKA WATER & WASTEWATER SGAIE J.L M.
CONSULTANTS, INC.
6901 MARR ROAD, SUITE 20 - ANC M"IS AK "SOL • FIIONE (907)337'6179 • FAX 07U36J266 1" = 100
PREPARED FOR PHONE NUMBER: PAGE NUMBER:-
JEFF
UMBER:JEFF HENDRIKSON 565-4799 1 OF 4
7953
FOREST RIDCE SUBDIVISION; LOT 11, BLOCK 1,
OF WORK:
SITE PLAN FOR PROPOSED WELL AND SEPTIC SYSTEM
RIDGE S/D
BLOCK 1,
I I
I I
I I
I I
I I
I I
INST.
VALVE
Sm
\ I '
\y I
I I
I
I I
I _ I \wr
1 wrI
I c l I I I
II L—WMT I
I I /
X SEPTIC
SYSTEM
/ I SETBACK
FI
/ PROPOSED 2000 GALLON SEPTIC TANK
WTTH ADVANTEX TREATMENT SYSTEM
AND A UFT STATION. (SEE PACE 3 OF 4)
5 BED OM
HOUSE
:.
I \ n4 4
SMT
—PROPOSED DRAINFIELO. EXCAVATE \
A BED THAT IS 2 FEET DEEP MAX. \
BY 10 FEET WIDE BY 40 FEET LONG.
ADD 0.5 TO 1 FOOT OF LEVELING
SAND AND THAN 0.5 FEET OF CLEAN.
WASHED SEWER DRAINROCK. (SEE
DETAIL DRAWING. PACE 4 OF 4).
mi
ALASKA WATER & WAS TEANVATER
CONSULTANTS, INC.
om sinew men CFTC m • .Nfm rp " "sm • FM (007"374170 • FA% (00)13m -32L
JEFF HENDRIKSON
1/2/2001
WN BY:
J.LM.
LE:
1"=30'
565-4799 1 2 OF 3
FOREST RIDGE SUBDIVISION; LOT 11. BLOCK 1.
OF WORK:
DESIGN OF PROPOSED WELL AND SEPTIC SYSTEM
THE AX -10 PODS
AdvanTex Treatment System P THEA SHALL BE PLUMBED
AX Series - Mode la C9D AwANrF�c SO THAT THEY CAN
Three (3) 34x48 Pods
p.m slvn.• EACH BE ISOLATED.
I TTODFILTTEERRK
INLET
el
NOTE: THE BOARD INSULATION TO BE
INSTALLED OVER THE SEPTIC TANK & 4'
BEYOND ON ALL SIDES EXCEPT UNDER
THE ADVANTEX FILTER. THIS WILL ALLOW
FOR HEAT TO ESCAPE FROM TANK k
RISE TO THE FILTER ABOVE IT.
FINAL GRADE
2" INSULATION,
194'
-THREE (3) AX -10
FILTERS CONNECTED
TOGETHER.
EASSA M
M DR/AFIELD
UFT STATION
INLETQ
ORENCO
BIOTUBE
2000641M SCREENED
5SIP, " VAULT
` ENCO
EFFLUENT
PUMP
DATE 9odp
4/2/2001 OF
P�
eis!� I DRAWN BY: op Af ALASKA `TATER & WASTRWATRR J.L.M.CONSULTANTS, INC. SCALEN.T.S. "6901 DEBARR ROAD. SUITE 28 • ANCHORAGE, AK 99504' FlIONE 07133 7-0179' FAK 907)33"246 REPAIRED FOR: PHONE NUMBER: PAGE NUMBER:
JEFF HENDRIKSON (907) 565-4799 3 OF 4
FOREST RIDGE SUBDIVISION; LOT 11, BLOCK 1
DETAIL AND PROFILE OF ADVANTEX TREATMENT SYSTEM
on- O %A a-, Ou-r�.�S Aa dA-
40
s-t�a- ;-►a ti
LON
FEET LANG U
PgA1NN SITE
------------------------0
I I
I
I I
I
INSTALL DNERTER , O ,
VALVE IF ALTERNATEli
------------------------J
SITE IS INSTALLED. ---------
FROM ADVANTEXLt-1/4 INCH SCH. 40 PVC DISTRIBUTION LINES
TREATMENT SYSTEM WITH 1/4 INCH DIA. HOLES SPACED 30 INCHES
ON CENTER. 15 HOLES PER LATERAL.
30 HOLES TOTAL IN EACH BED. -7
PI tERJA1E SITE F ----------------------- ----------I
o,
I
I I
I
I I
I I
INSTALL MONITORING ----------------------------------J
TUBE (TYPICAL)
38 FEET LONG LATERAL
GRADE
FABRIC
ADD 0.5 TO 1.0 FEET (61_1/4 INCH DIALIETER SCH. 40 PVC
OF LEVELING SAND DISTRIBUTION LINES WITH 1/4 INCH DIAMETER
HOLES SPACED 30 INCHES ON CENTER.
15 HOLES PER LATERAL - 30 HOLES TOTAL
10' WIDE
DATE:
A /n /nnnA
NZ7_y7A
2 FEET DEEP
MAXIMUM- AT
ANY POINT
ALASKA R'ATI:R & WASTENNIATER J.L.M.
CONSULTANTS, INC. SCALE. O '�
6901 DESARR ROAD. SURE ire • ANCHORAGE. AK 90504 • PHONE 07)377-6179 • FAX 07)376-5246 N.T.S. Q
REPAIRED FOR: PHONE NUMBER: PAGE NUMBER: O
JEFF HENDRIKSON (907) 565-4799 4 OF 4 Q re GGrness-
-GAL DESCRIPTION: QO ° C 7953 i)
FOREST RIDGE SUBDIVISION; LOT 11, BLOCK 1, Nda
rPE OF WORK: �44,•dp�o/esslo0a Ecom
DETAIL AND PROFILE OF PROPOSED BED SYSTEM
1
MIN
1
AILASKA WATER & WASTEWATER
CONSULTANTS, INC.
6901 DOM" Rw. SUFE 28 •ANCHORAGE AK •YOM • PHDNE (907)337-617Y *TAY:-(9Oi}T7B-U4-
SOIL LOG - PERCOLATION TEST
LEGAL DESCRIPTION: FOREST RIDGE SUBDMSION; LOT 11, BLOCK 1
PERFORMED FOR: JEFF HENDRIKSON DATE: 3/16/2001
88 ORGANICS TEST HOLE 1
1
2—il w 1 i n 11 GM WITH SAND
3
4
5
71#111#1 SM LENSE IT ML
8
9
10
11
15
16
17
18
19
DEPTH TO
GROUNDWATER
DATE
SEEPS o 3' & 4'
3/16/01
3.5'
3/21/01
2:51
—
6'
—
2
3:21
30
5-1/2'
1/2'
/.%1
3:21
i
6'
—
4
3:51
11
1 5-5/8'
3/8'
5
3:51
—
6'
—
6
•
0!4II1.1
5-5/8'
3/8'
DEPTH TO
GROUNDWATER
DATE
SEEPS o 3' & 4'
3/16/01
3.5'
3/21/01
2:51
—
6'
—
PROPOSED
5 BEDROOM
DATE READING
CLOCK
TIME
NET TIME
(MINUTES)
WATER LEVEL
READING
NET DROP
(INCHES)
3/21/01 1
2:51
—
6'
—
2
3:21
30
5-1/2'
1/2'
3
3:21
—
6'
—
4
3:51
30
1 5-5/8'
3/8'
5
3:51
—
6'
—
6
4:21
30
5-5/8'
3/8'
PERCOLATION RATE 80 (MINANCH) PERC. HOLE DIA. 6' (INCHES)
20 1 TEST RUN BETWEEN 1.5 FT. AND 2.0 FT.
COMMENTS: PERC—HOLE WAS PRE—SOAKED FOR 4+ HOURS
PERFORMED BY ALASKA WATER do WASTEWATER I, JEFFREY A. C•ARNESS. CERTIFY THAT THLS/343fOPERFORMED l
IN ACCORDANCE WITH ALL STATE AND MUNICIPAL GUIDELINES IN EFFECT ON THIS DATE: 4 /f
I
ALASKA WATER & WASTEWATER
CONSULTANTS. INC.
LEGAL DESCRIPTION: FOREST RIDGE SUBDMSION: LOT 11, BLOCK 1
PERFORMED FOR: JEFF HENDRIKSON DATE: 3/16/2001
( eat) ===ORGANICS ITEST HOLE 2
IGROUNDWATERI DATE
PROPOSED
5 BEDROOM
HOUSE' _
L
DATE READING
CLOCK
TIME
NET TIME
(MINUTES)
WATER LEVEL
READING
CLASSIFICATIONS
3/21/01 1
2:50
rrSOIL
6'
rGW
2
3:20
30
4'
2'
3
3:20
OR
6'
r
4
jGPIIII11111MIL
30
4-1/2'
1-1/2'
1
3:50
r
�lil'GM
CIL/�
6
4:20
30
4-1/2'
1-1/2-
•
I
j0
00 00, SWIIIIIIIIIMH
rCH
SM
OHI
I
I
GM WITH SAND SC
IGROUNDWATERI DATE
PROPOSED
5 BEDROOM
HOUSE' _
L
DATE READING
CLOCK
TIME
NET TIME
(MINUTES)
WATER LEVEL
READING
NET DROP
(INCHES)
3/21/01 1
2:50
—
6'
—
2
3:20
30
4'
2'
3
3:20
—
6'
4
3:50
30
4-1/2'
1-1/2'
5
3:50
—
6'
—
6
4:20
30
4-1/2'
1-1/2-
19 PERCOLATION RATE 20 (MINANCH) PERC. HOLE DIA. 6' (INCHES)
20 TEST RUN BETWEEN 2.5 FT. AND 3.0 FT.
COMMENTS: PERC-HOLE WAS PRE-SOAKED FOR 4+ HOURS Wo e 5.5, r• 1�
PERFORMED BY ALASKA WATER k WASTEWATER I. JEFFREY A. GARNESS, CERTIFY THAT THISIWAA PERFORMED I
IN ACCORDANCE WITH ALL STATE AND MUNICIPAL GUIDELINES IN EFFECT ON THIS DATE: o
Z
g
a.
0
"'FOREST RIDGE SUBDIVISION' BLOCK 1 LOI IU
oRAWNJ, ANDERSON cKD. R.A.S. I DATE8_15_94 ISHT. 1 OF 1
DESIGN CRITERIA:
STRUCTURES, EASEMENTS, OR ENCROACHMENTS
SHOWN ON THIS SITE PLAN ARE AS SHOWN ON
AN AS -BUILT SURVEY DRAWN BY:
GASTALDI LAND SURVEYING
IT IS THE RESPONSIBILTIY OF THE CONTRACTOR
TO VERIFY EASEMENTS, REQUIRED SEPARATION
DISTANCES, AND PROPERTY LINES PRIOR TO
CONSTRUCTION.
10' UnL ESUT
I
I
•THJI
I
I
• THjz
I
I
LOT 9 LOT 10
I
I
flz
ELL RADIUS
I
I
I
LOT 11
PROP.
µ LL
Gv`
°•sem
Ko
CONTRACTOR IS REQUIRED TO
OBTAIN UTILITY LOCATES
PRIOR TO ANY EXCAVATION
WORK.
CLI
nc ccrtt+ wr v.n. ,x
xars.++, n wir sn[
cv:a+cus
PERFORMED
LEGAL DESC,
P
t 11,
2 It 11
3-
4-
5-
6-
7-
10-
11
45671011
12
13
14
15
1s
17
18
19
20
SLOPE SITE PLAN
MANIC$
FkA T (
GA&
GM- GRauEc — sFwo - src7
MuTUIE — VEPy WET.
3-20-93 a`
ob- I a
�.
PERCOLATION RATE —J60— (minutevmcn) PERC HOLE DIAMETER
TEST RUN BETWEEN 3 FT AND Y r FT
COMMENTS
S & S ENGINEERING
PERFORMED BY: 17C34 liask
pta� e vw qp�7� CERTIFY THAT THIS TEST WAS PERFORMED IN
ACCORDANCE WITH K*L9�ATFANDIMUNICf 1 GUIDELINES IN EFFECT ON THIS DATE. DATE:
72.008 (Rev. 4185)
Y
WAS WATER
ENCOUNTERED?
S
IF YES, AT WHAT
'n L
p
DEPTH?
E
WAgE2
Depth to Wafer After
AA-..—..w....l
Monitoring?
Daly
3-20-93 a`
ob- I a
�.
PERCOLATION RATE —J60— (minutevmcn) PERC HOLE DIAMETER
TEST RUN BETWEEN 3 FT AND Y r FT
COMMENTS
S & S ENGINEERING
PERFORMED BY: 17C34 liask
pta� e vw qp�7� CERTIFY THAT THIS TEST WAS PERFORMED IN
ACCORDANCE WITH K*L9�ATFANDIMUNICf 1 GUIDELINES IN EFFECT ON THIS DATE. DATE:
72.008 (Rev. 4185)
Y
+� O
...OFq
to�•1E}1GIN .A9
:ti9$
is
a� Municipality of Anchorage ^r �Z'• •'0"'«'�"'
1\C DEPARTMENT OF HEALTH & HUMAN SERVICES... ,`�in IAFE
,... (Tm�..
y 825 "L" Street, Anchorage, Alaska 99502 0650 :?t,R 4w,0
SOILS LOG — PERCOLATION TEST ria. 82 5•,.•���
PERFORMED FOR: J9C11NN 4J%i1LDERS /914c- :/; CV/L DATE PERFORMED: � 5
o�EO LaT /0 r 8uL 1
LEGAL DESCRIPTION: Pnz?gs-r �I D&E -11/1) Range, SectionRange. Section:
1
2
3
4
6
6
7
8
9
10
11
12
13
14
15
16
17
18
19
Yi, — 1' WZ j 094A -KS
snA. - sw%y C* -a /
4^'h -• SILty SA. oy G'/tM/t?C
WITH Scala, G AIASY &W&-
LErvs�
(T'A— %w-ly Sh+ey 69w r.L
Wru
WASGROUND WATER
ENCOUNTERED?
IF VES, AT WHAT
DEPTH?
de—DeDU to Water Alter
X—monitoring?
�I
SLOPE
SITE PLAN
■■■■■■■■■■
20 lul PERCOLATION RATE 11= (mmutes/mc��n++) PERC HOLE DIAMETER
TEST RUN BETWEEN � FT AND —I.—FT
COMMENTS
S & S ENGINEERING
PERFORMED BY:oop I � CERTIFY THAT THIS TEST WAS PERFORMED IN
ACCORDANCE W1S1k9 RITATEAiRfJVRLV97AL GUIDELINES IN EFFECT O THIS DATE. DATE:
72-M (Rev. 4/85) . .
MUNICIPALITY OF ANCHORAGE
Development Services Department Phone: 907-343-7904
On -Site Water & Wastewater Section Fax: 907-343-7997
Parcel I.D. 017-113-13
1
Certificate of On -Site Systems Approval
Expiration Date: (- — 1 �7 – 2 Q
GENERAL INFORMATION
Complete legal description FOREST RIDGE BLK 1 LT 11
Location (site address) 5201 Bishop's Castle Cir
Current property owner(s) PLANTENGA
Mailing address
Real estate agent
2. TYPE OF DWELLING:
0. Single Family (w/wo ADU)
❑ Duplex
❑ Multiple Dwellings (Single Family and/or Duplex)
3. NUMBER OF BEDROOMS: 5
Day phone 503.910-4878
Day phone
4. TYPE OF WATER SUPPLY:
TYPE OF WASTEWATER DISPOSAL:
Private Well
Q
Private Septic
Z
Water Storage
❑
Holding Tank
❑
Community Well
❑
Community
❑
Public Water System
❑
Public Sewer
❑
Waiver request for: Distance:
Received by: Date:
COSA to be released to the engineer, unless otherwise requested by the engineer.
COSA Fee $ 5_60 ,
Date of Payment 10 IQ 0��
Receipt Number 0 6 0 71 IJ
COSA # _ 05C22 10 7'3
Waiver Fee $
Date of Payment
Receipt Number
Waiver #
5. STATEMENT OF INSPECTION BY ENGINEER
As certified by my seal affixed hereto and as of the validation date shown below, I verify that my investigation, based
on procedures outlined in the Certificate of On -Site Systems Approval Guidelines for this application, shows that the
on-site water supply and/or wastewater disposal system is (are) safe, functional and adequate for the number of
bedrooms and type of structure indicated herein. I further verify that based on the information obtained from the
Municipality of Anchorage files and from my investigation and inspection, the on-site water supply and/or wastewater
disposal system is (are) in compliance with all applicable Municipal and State codes, ordinances, and regulations in
effect at the time of installation. I acknowledge that On -Site staff may visit the site to verify the information submitted.
Name of Firm NorthRim Eng. Phone 694-7028
Address PO Box 770724, Eagle River
Engineer's Printed Name Steve Eng Date 2/10/22
OF
ir
jW
6. DSD SIGNATURE
♦� sem. .
System #1 Approved for bedrooms
System #2 Approved for bedrooms 2
Disapproved
Conditional approval for bedrooms, with the following stipulations:
Original Certificate Date:
The Municipality of Anchorage Development Services Division (DSD) issues Certificates of Onsite Systems Approval (COSA) based only upon the
representations given in paragraph 5 by an independent professional civil engineer registered in the Stale of Alaska. The Municipality of Anchorage is
not responsible for errors or omissions in the professional engineer's work.
7. ATTACHMENTS:
COSA Checklist X
Septic System Advisory
Well Flow Advisory
COSA Ched-Aist blue sheer
Nitrate Advisory
Arsenic Advisory
Other S fe 4-4&4 ,ed STQ21�a.►1(�
Legal Description: FOREST RIDGE BLK 1 LT 11
If more than 1 septic system on lot: COSA Checklist # of
A. WELL DATA
❑ Well log is filed with Onsite (or attached)
Date drilled 4113/01
Total depth 73 ft
Cased to 73 ft
no Sanitary seal is functioning correctly
❑ Wires are properly protected
Casing height (above ground) 36 in.
Date of flow test for COSA 2/11122
Static water level at beginning of test 31 ft.
Comments
B. TANK DATA
Age of tank(s) 20.5 years
Tank type/material . Stl
Measured operating fluid level in septic tank
❑ Standpipes/foundation cleanout per record drawing
Date of pumping Note Advantex Maintenance
D. ABSORPTION FIELD DATA 6/27/01
Which system tested (date installed) same
❑ ALL standpipes present per record drawing
Total measured depth from grade 3 ft (max)
Measured depth to pipe invert from grade ft (min)
❑ N/A — pressurized field
❑ Monitor tubes go to bottom of effective. If not, state
depth into effective
❑ Code -required soil cover over field
❑ System presoaked
(Required if vacant for greater than 30 days prior to
date of test)
Gallons introduced gallons
Comments/Deficiencies:
COSA Checklist yellow sheet
Parcel ID: 017-113-13
Structure served by this system
Well production at time of test 8+ gpm
Water storage tank volume 0 gallons
Well disinfected for coliform test? ❑ Yes ❑ No
❑ Coliform bacteria is Negative
Nitrate mg/L On Nitrate less than MRL (ND)
Arsenic ug/L ❑ Arsenic less than MRL (ND)
Collected by NRim Eng
Date of Sample 2/11/22
C. LIFT STATION
❑ Required maintenance completed
Age of lift station 20.5 years
Lift station material Stl
Comments:
Adequacy test date 2/11122
Results [DPass For 5 bedrooms
Fluid depth prior to test 1 in
Water added 750 gal
New depth 6 in
Elapsed time 60 min
Final fluid depth 1 in
Absorption rate 750 gpd
Any rejuvenation treatment (past 12 months) no
If yes, enter date
E. SEPARATION DISTANCES
From Private Well on Lot to: (Please enter distances if less than required or if community well)
Septic Tank/Lift Station on Lot > 100'
[E]
Yes
Community Sewer Manhole/Cleanout > 100'
1 [0 Yes
if No
It
[2 Yes
if No ft
Neighboring Tank > 10U V Yes
if No
ft
Private SewerlSeptic Line > 25' Yes
if No ft
Absorption Field on Lot > 100' R] Yes
if No
ft
Holding Tank> 100' Yes
if No ft
Neighboring Absorption Fields > 100'
Q Yes if No It
Water Main > 10'
Animal Containment > 50' ['Yes
if No ft
Sa Yes
if No
ft
Yes if No ft
Water Service Line > 10'
Yes
if No
Manure/Animal Excreta Storage > 100'
If septic tank is under driveway
Community Sewer Main > 75' Q Yes
if No
ft
�J Yes
if No ft
From Septic/Holding Tank on Lot to: (Please enter distances if less than required)
Building Foundations > 10'
[E]
Yes
if No
ft
Surface Water > 100'
El Yes if No ft
Property Line > 5'
My
Yes
if No
ft
Wells on Adjacent Lots:
Absorption Field > 5'
if No
Yes
if No
ft
Private Wells > 100'
Q Yes if No It
Water Main > 10'
ft
Yes
if No
ft
Community Wells > 200'
Yes if No ft
Water Service Line > 10'
Yes
if No
ft
If septic tank is under driveway
comment below
From Absorption Field on Lot to: (Please enter distances if less than required)
Building Foundation > 10*
Yes
if No
ft
If absorption field is under driveway comment below
Property Line > 10'
Yes
if No
ft
Wells on Adjacent Lots:
Water Main > 10'
Yes
if No
ft
Private Wells > 100' Yes if No ft
Water Service Line > 10*
Yes
if No
ft
Community Wells > 200' Q Yes if No ft
Surface Water > 100'
Q
Yes
if No
ft
F. ENGINEER'S COMMENTS
G. ENGINEER'S CERTIFICATION
/ certify that / have determined through field inspections and review
of Municipal records that the above systems are in conformance with
MOA COSA guidelines in effect on this date.
.49
Steve Eng
CE -62W
07/06/2021 14:35 8686770
APLUS
394 615 r
am III moseam son III onamon am BE III am 8
�
Room e �a
Field Maintenance Report
Annual Inspe ,-tion
PAGE 08
AnchorageTank
907-272-3543
Proparty 0wnarfn=king t
Current
oporator
Currant
Alex & Melissa Plani mga
2nd Compartment
Larry Betts
Previous
Site Addreaa
Prevlous
Contact Phone
5201 Bishops Casty Circle, Anchorage AK 99516
(907) 743-0347
AX $ttw ID p
County ID !1
Pod 0
RTU NIUL $
Detn 01 Lost InspeoUon
AX -100086
SW970254
RTU 100066
11/04/2020
Retrieve O&M Info
Dally now -
Recirc ratio
Timor settings:
Perform Field Sampli hg/Observations
NTU (1$:t NTlls) pH 16-9) DO (2-6)
,`? G,<
Odor of Sample `
7YPIC31 ❑ Musty A Earthy 0 Moldy
Non -typical ❑ Sulfkh ❑ Cabbage 0 Decay
oily flim in PVU C Yes A No
Foam In tank Yes - No
Ile
Check Control Panels
Recire Amps Discharge Amps
Audible and visual alert is 210
Dial tone (telemetry oni -) L Yes �ND
Inspect/Clean Pump !system
Inspect Olean
Riser/Lid ........... .........r(�
Splice Box .......... ..... ...fJ�
Roat Cords _ ..... _ .. _ . _ ...
Floats.............. .........
Pump.............. .......... J
Blotube Filter ....... ...........
8iotube Pump Vault .. . _ . _ ....
Recirculating Splftter If,, luo....... 12
Signature _9-0
Measure Siudge/Scum
Sludue
Scum
latcompartment
Current
Previous
Currant
Previous
2nd Compartment
uMOV
Previous
Current
Prevlous
M "
inspect/Clean AdvanUx Fitter
Odor_ )ZNormal ❑ Pungent
eiomat: —ONormal ❑ Excessive
Brldging/Ponding: ONono/Minor ❑ Excessive
Inspect/Clean Discharge Pump System
Inspect
Riser/Lid X
Splice Box
Float cords .+"
Inspect/Service Other System Components
In. -Peet Clean
Late Bottom Pod Bottomm
rrr---ttt
Intake Vent
Inspect
Clean
Floats
Pump
Inspect Clean Inspect Clo
Disinfection EquipmentDispersal Lateralafdrifio� a( 1
Observations
Additional Services Rendered
❑ Cleaned toxtilo sheets? ❑ Replaced UV Rams?
❑ Replaced/Used other items?
Parts Used: W - Warranty, 8 - Billable (✓ appropriate selection)
w R Item Number Description
Final/S,afety inspection
(RSV reinstalled
/Manifold reconnected; flush valves closed
Summary/Recommendations
System performing; no further action needed
❑ Call for service
bate
Fax compi+efad farm to 1.1306-384-7404
lids bolted on
Control panel reactivated
❑ Tank needs pumping
❑ other?
k.,
Septic Tank Advisory
Certificate of On -Site Systems Approval #OSC 221078
Subdivision: Forest Ridge B 1 lot 11
Starting at 20 years of age the MOA issues Advisory's for steel septic tanks. The septic tank for
this COSA / property is 20.5 years old. A leaking septic tank may be a source of contamination to
the aquifer. Typical replacement costs range from $10,000 to $15,000
This advisory must be attached to all copies of the subject Certificate of On -Site Systems
Approval.
This is an example of a 16 -year-old septic tank.
Mailing Address P O Box 196650 *Anchorage, Alaska 99519 6650 *www muni org
MUNICIPALITY OF ANCHORAGE
ADVANCED WASTEWATER TREATMENT SYSTE
MAINTENANCE AND REPAIR AGREEMENT I
THIS MAINTENANCE AND REPAIR AGREEMENT, herein the -"AGREEMENT" made and
entered into as of this --LS- Day of mAQ-c-14 of 20 ?-a, by and between
herein the "OWNER." and the Municipality of
Anchorage, herein the "MUNICIPALITY", in accordance with Anchorage Municipal Code
(AMC) 15.65.365. In consideration of the mutual covenants contained herein, the parties to this
Agreement agree as follows:
1. Advanced Wastewater Treatment Systems. The Municipality grants permission to the
Owner to utilize and operate an Advanced Wastewater Treatment System (AWWTS),
described as A SO \,/AV 1 EY - f!--
located at (legal description) FOIZE-ST iz1DC-1,;1 t3LK-I 40-FL1
5�- 01 53.StH �Q P�'- CA -, 7 L6 M GU o QLA G-
2. Maintenance, Repairs and Alterations.
(Owner is required to read. understand and initial each section)
SA— Throughout the term of this Aareement, the Owner shall enter into a service a,,reement
with an AWWTS service and maintenance provider approved by the Municipality or the
manufacturer's representative. The AWWTS shall be maintained in a satisfactory
w
condition capable of perfori-ninor_1 as designed and producing treated septic of uent in
accordance with the equipment's approval for operation in the Municipality.
It shall be the responsibility of the Owner during the term of this Agreement to pay for all
repair(s), maintenance, adjustment(s), replacement costs, and inspection costs. This
includes an annual maintenance fee (typically $400 to $600).
,S-6— Owner agrees that only maintenance and repair personnel approved by the Municipality
or the manufacturer's representative will inspect and make any necessary maintenance,
repairs or permitted alterations to the system.
Owner
acknowledges that regular maintenance of an AWWTS reduces the potential
C,
failure of the system, which could include sewage backup and costly repairs or drainfield
replacement.
(rev. 05/18/2018) Paye 1 of 3
Owner acknowledges that the Municipality may request records of maintenance and
repairs from the manufacturer's representative or maintenance provider,
Y-6 Owner acknowledges that the fine for failing to maintain and repair an AWWTS may be
assessed in accordance with AMC 14.60.030.
S�E Owner agrees to grant the Municipality reasonable access to test and inspect the
AWWTS. The Municipality will give at least 24-hour notice.
Owner agrees that any sale or transfer of title of the property will not occur without a new
Certificate of On -Site Systerns Approval.
S_-6 Owner agrees that the AWWTS installation and maintenance requirements as provided
by the AWWTS vendor/installer and approved by the Municipality are the governing
guidelines for the construction, maintenance and repair of the Owner's AWWTS.
,�E Owner agrees to maintain remote monitoring of the AWWTS as required by the
A WWTS approval.
3. Term. The term of this Agreement shall be -in on the date of approval by the
Municipality to operate the installed system, or upon transfer of title, and shall continue
while the AWWTS is operational or until title is transferred.
4. Nonwaiver. The failure of the Municipality at any time to enforce a provision of this
I
Agreement shall in no way constitute a waiver of the provisions, nor in any way affect
Z__ I
the validity of the Agreement or any part hereof or the right of the Municipality
thereafter to enforce every provision hereof.
5. Amendment. This Agreement shall only be amended by authorized representatives of
the Owner and Municipality. Any attempt to amend this agreement by either an
unauthorized representative or unauthorized means shall be void.
6. Jurisdiction: Choice of Law. Any civil action arising from this Agreement shall be
Z-17
brought in the Superior Court for the Third Judicial District of the State of Alaska at
Anchorage. The laws of the State of Alaska shall govern the rights and obligations of the
parties under this Agreement.
7. Severability. Any provisions of this Agreement decreed invalid by a court of competent
jurisdiction shall not invalidate the remaining provisions of the Agreement,
C, C�
(rev. 05/18/2018) Paae 2 of 3
OWNER:
By: `— (signature) Date: l 1 f0e �2-
-nl name)
v
STATE OF A�A'�KA )
ss.
THIRD JUDICIAL DISTRICT )
The foregoing instrument was acknowledged before me this _ f Nay of 161,4 t .-- !7 ,
20yi, by C?e�rP - d -t?.» .
STATE OF MARYLAND
My Comm. E --ire, 5/.1J2'0-
MUNICIPALITY:
/.1/2'0
MUNICIPALITY:
BY (signature)
.(print name)
(rev. 05/18/2018)
Date: 3 — 15-- 2 C9 ZZ
Title:
Page 3 of 3
•e`
Municipality of Anchorage
On -Site Water and Wastewater Program
(907) 343-7904
CERTIFICATE OF ON-SITE SYSTEMS APPROVAL
Parcel I.D. 017-113-13
1. GENERAL INFORMATION
Complete legal description FOREST RIDGE BLOCK 1 LOT 11
Expiration Date: to - 3-i 2
Location (site address) 5201 BISHOP'S CASTLE CIRCLE ANCHORAGE AK 99516
Current Property owner(s) GARY & CHRISTINA TARGAC Day phone
Mailing address 5201 BISHOP'S CASTLE CIRCLE ANCHORAGE AK 99516
Real Estate Agent
2. TYPE OF DWELLING:
® Single Family (w/wo ADU)
❑ Duplex
❑ Multiple Dwellings (Single Family and/or Duplex)
Day phone
3. NUMBER OF BEDROOMS:
5
TYPE OF WASTEWATER DISPOSAL:
4. TYPE OF WATER SUPPLY:
Individual
Individual Well
®
Holding Tank
❑
Individual Water Storage
❑
Community
❑
Community Class —well
1-1Public
Sewer
❑
Public Water System
❑
WaiverNariance request
Received by: -.",&�
COSA to be released to the engineer,
COSA Fee $ 6-9(0 .
Date of Payment SI2q I a
Receipt Number 062 0
COSA#D.5 jl22i
11 Date: /N.�'
by the engineer.
Waiver Fee $
Date of Payment
Receipt Number
Waiver #
6. STATEMENT OF INSPECTION BY ENGINEER
As certified by my seal affixed hereto and as of the validation date shown below, I verify that my investigation,
based on procedures outlined in the Certificate of On -Site Systems Approval Guidelines for this application,
shows that the on-site water supply and/or wastewater disposal system is (are) safe, functional and adequate
for the number of bedrooms and type of structure indicated herein. I further verify that based on the information
obtained from the Municipality of Anchorage files and from my investigation and inspection, the on-site water
supply and/or wastewater disposal system is(are) in compliance with all applicable Municipal and State codes,
ordinances, and regulations in effect at the time of installation.
Name of Firm ARCTERRA CONSULTING INC Phone 868-3791
Address 20441 PTARMIGAN BLVD., EAGLE RIVER AK 99577
Engineer's Printed Name KENNETH M. DUFFUS Date 5/2212018
••• engmaers i-ammenrs: i ms investigation was commercial in compliance with
ADEC and MOA regulations. The assessment of the condition of the well and septic applies only to the conditions as of the day tested.
The flow and absorption rates may change due to subsurface conditions that may not be observed from the surface, changes inland use,
local soil characteristics, groundwater levels that may fluctuate during the year and the water usage of the family being served by the
system. The operational life of all well and septic systems are subject to these various and dynamic characteristes and are outside the
control of the evaluator of the well and septic system. Therefore, ArcTerra can not give any estimate of how long a system will function
satisfactory for current or future occupants or can ArcTerm guarantee that no unseen _�_\
encroachments, deficiencies or discrepancies exist. - ` OF �,r�\
�Y � Sf7'11
6. DSD SIGNATURE _
%i4
System #1 Approved for bedrooms. / xEM1TETH D
r e /
System #2 Approved for _ bedrooms. 1 ss '4'i
Disapproved. 1 \% .es
\\i
Conditional approval for bedrooms, with the following stipulations:
Original Certificate Date: —7-22
The Municipality of Anchorage Development Services Division (DSD) issues Certificates of Onsite Systems Approval (COSA) based only
upon the representations given in paragraph 5 by an independent professional civil engineer registered in the State of Alaska. The Municipality
of Anchorage is not responsible for errors or omissions in the professional engineers work.
7. ATTACHMENTS:
COSA Checklist X Nitrate Advisory
Septic System Advisory Arsenic Advisory
Well Flow Advisory Other
COSTCNs1wL1P10.12.tlm
If more than 1 septic system Is on the lot:
COSA Checklist # of
Structure served by this system _
Certificate of On -Site Systems Approval Checklist
Legal Description: FOREST RIDGE BLOCK 1 LOT 11 _ parcel ID. 017-113-13
A. WELL DATA
Well type PRVT If A. B, or C provide PWSID # _ Well Log (YIN) Y
Date completed 411312001 Sanitary seal (YIN) Y Wires properly protected (YIN) Y
Total depth 73 ft. Cased to 73 ft. Casing height (above ground) 36 in.
FROM WELL LOG AT INSPECTION
Date of test 4/13/2001
Static water level 31 ft.
Well production 30 g.p.m.
WATER SAMPLE RESULTS:
Coliform NEG colonies/100 mL NitrateHP-mg/L
Arsenic: ND ug/L Date of sample: 5118122018
B. SEPTICIHOLDING TANK DATA
511812018
30 ft.
7 g.p.m.
Collected by: ARCTERRA
Tank Type/Material ADVANTEXISTEEL Date installed 612712001
Tank size 2000 gal. Number of Compartments 2 Cleanouts (YIN) Y
Foundation cleanout (YIN) Y Depression over tank (YIN) N High water alarm (YIN) Y
Date of pumping 511712018 Pumper At HOME SERVICES IADVANTEX MAINTENANCE
C. ABSORPTION FIELD DATA
Date installed 6127/2001 Soil rating ( _Lid /ftr or�2.0 System type BED
Length (West) 40140 (East) ft. Width 10110 ft. Gravel below pipe 0.7 ft.
Total depth 2.8r ft. (measured 5/18/16) Eff. absorption area 400 1400 11Monitoring lube Y Depression over field N
Date of adequacy test 5118118 Results (Pass/Fail) PASS For 5 bedrooms
Fluid depth in absorption field before test 110.5 in. Water added 6001750 gal. New depth 1117 in.
Elapsed Time: 1440 min. Final fluid depth 310.5 in. Absorption rate >= 750 g.p.d.
Any rejuvenation treatment (past 12 mo.) (YIN & type) N If yes, give date
D. LIFT STATION
Date installed 8/272001 Size in gallons 2000 Manhole/Access (Y/N) Y
"Pump on" level at TIMER in. "Pump off" level at TIMER in. High water alarm level at 45 in.
Datum Bottom of Tank Cycles tested 2 Meets alarm & circuit requirements? Y
E. SEPARATION DISTANCES
WELL ON LOT TO:
Septic tank1lift station on lot 100'+ On adjacent lots
Absorption field on lot 1001+ On adjacent lots
Public sewer main 751+ Public sewer manhole/cleenout 100'+
Sewer /septic service line 251+ Holding tank 100'+
Animal containment areas 50'+ Manure/animal excrete storage areas 1001+
SEPTIC/HOLDING TANK ON LOT TO:
Building foundation 10'+ Property line 5'+ Absorption field 5'+
Water main 101+ Water service line 10'+ Surfacewater 1004
Wells on adjacent lots 1001+
ABSORPTION FIELD ON LOT TO:
Property line 101+ Building foundation 10'+ Water main 10'+
Water Service line 10'+ Surface water 1001+ Driveway, parking/vehicle storage 10'+
Curtain drain 50'+ (NONE KNOWN) Wells on adjacent lots 100'+
F. COMMENTS
G. ENGINEER'S CERTIFICATION
I certify that I have determined through field inspections and
review of Municipal records that the above systems are in conformance
with MOA COSA guidelines in effect on this date.
Engineer's Printed Name KENNETH M. DUFFUS
Date 5222018
CASA canary sheet_2t,15.dm
- 'k 'k
Ar �� OF ALS\
+4.9 TH 1'
� A KENNen9r
DowSgn Envelape ID: 5213006542A0416bADE3-6D2072DC49FB
ADVANCED WASTEWATER TREATMENT SYSTEM MAINTENANCE AND
REPAIR AGREEMENT BETWEENMUNICIPALITYOF ANCHORAGE
AND
Alex R plantenga
THIS MAINTENANCE AND REPAIR AGREEMENT made and entered into as of this
zD Day of July of 2018 , by and between Alex R ptantenga
herein the "OWNER," and the Municipality of Anchorage, herein the
"MUNICIPALITY." In consideration of the mutual covenants contained herein, the
parties to this Maintenance and Repair Agreement agree as follows:
1. Advanced Wastewater Treatment Systems. Municipality giants permission to
Owner to utilize and operate an Advanced Wastewater Treatment System
(AWWTS), described as Adyantex AXIO
located at (legal description). Forest Ridge Blk 1 Lot 11.
5201 Bishop's Castle. Anchorage
2. Definitions.
Alteration. Any change to the design or function of an AW WTS that includes the
installation or removal of any parts, components or pieces not included in the
original construction permit and design.
Certificate of On -Site Systems Approval (COSA). An approval by the
Municipality of existing water and wastewater disposal systems given at the time
of property sale and title transfer in accordance with Anchorage Municipal Code
(hereinafter, "AMC") 15.65. These approvals certify that the systems are adequate
for the homes that they support and meet the codes that were in place at the time
of system construction
Damage. Any man-made or natural change in a system that would inhibit the
system from performing as designed.
Maintenance and Repair. The scheduled and as needed replacement of existing
parts, components and pieces of an AW WTS that were included in the original
design which would allow the AW WTS to continue to perform as designed.
Permit. An On -Site Wastewater Disposal Permit as required by AMC 15.65 to
construct and operate an AW WTS
Do..Sgn Env lweID: 521a408542A04164-ADE3.6D2072DC49FB
3. Term. The term of this Maintenance and Repair Agreement shall begin on the date
of approval by the Municipality to operate the installed system or issuance of a
COSA, and shall continue while the AW WTS is in use or is operational or until
the property is sold or title is transferred by the owner and a new COSA is issued
to the new owner or transferee of the property.
4. Alterations, Installation and Removal of Additional Equipment. Prior to
performing any alterations to an AW WTS, the owner agrees to obtain an On-site
Wastewater Disposal Permit from the Municipality in accordance with AMC
15.65.
5. Maintenance and Repairs.
A. Throughout the term of this Maintenance and Repair Agreement, the Owner shall
maintain their AW WTS in a satisfactory condition capable of producing treated
septic effluent in accordance with the equipment's approval for operation in the
Municipality. The owner shall enter into a service agreement with an AW WTS
service and maintenance provider approved by the municipality and the
manufacturer of the AW WTS for the entire term of the AW WTS. In addition, it
shall be the responsibility of the Owner during the term of this Maintenance and
Repair Agreement, and any renewals thereof, at the owner's sole expense, to pay
for any and all: (1) repair(s), (2) maintenance, (3) adjustment(s), (4) replacement
costs, and (5) inspection costs.
B. Owner agrees to comply with all applicable ordinance, laws, regulations, rules
and orders for the AW WTS
C. Upon request by the Municipality, the owner agrees to provide the Municipality a
written schedule of routine maintenance and repairs which have been performed
on the system. When a record of maintenance is documented and maintained by
the system vendor, the owner agrees to allow the Municipality access to this
information.
D. Owner acknowledges that the fine for failing to maintain and repair an AW WTS
may be assessed in accordance with AMC 14.60 for improper discharge.
E. Owner agrees that only maintenance and repair personnel approved by the
Municipality will inspect and make any necessary maintenance, repairs or
permitted alterations to the system.
F. Owner agrees to grant the Municipality reasonable access to test and inspect the
AW WTS upon 24 hours written notice.
G. Owner agrees that any sale or transfer of title of the property will not occur
without a new Certificate of On -Site Systems Approval.
Docu5i9n Envelope ID: 521340B542A04164-ADE3dD2072DG9FB
H. Owner agrees that the AW WTS installation and maintenance requirements as
provided by the AW WTS vendor/installer and approved by the Municipality are
the governing guidelines for the construction, maintenance and repair of the
Owner's AW WTS.
1. Owner agrees to provide and maintain a telephone connection to the A W WTS as
required by the AW WTS approval.
6. Nonwaiver. The failure of either party at any time to enforce a provision of this
Maintenance and Repair Agreement shall in no way constitute a waiver of the
provisions, nor in any way affect the validity of the Maintenance and Repair
Agreement or any part hereof, or the right of such party thereafter to enforce each
and every provision hereof.
7. Amendment.
A. This Maintenance and Repair Agreement shall only be amended, modified or
chanced by a writing, execyted by authorized representatives of the parties, with
the same formality that this Maintenance and Repair Agreement was executed
with, and such writing shall be attached to this Maintenance and Repair
Agreement as an amendment.
B. For the purposes of any amendment modification or change to the terms and
conditions of this agreement, the only authorized representatives of the parties
are:
a. Owner: Al ez a pl antenga
b. Municipality: Director, Community Development or designated authority
C. Any attempt to amend, modify, or change this contract by either an unauthorized
representative or unauthorized means shall be void.
8. Jurisdiction: Choice of Law. Any civil action arising from this Maintenance and
Repair Agreement shall be brought in the Superior Court for the Third Judicial
District of the State of Alaska at Anchorage. The laws of the State of Alaska shall
govern the rights and obligations of the parties under this Maintenance and Repair
Agreement.
DowSign Envelope In 52134OBS 42A0 164-A E3-6D2072DC49FB
9. Severability. Any provisions of this Maintenance and Repair Agreement decreed
invalid by a court of competent jurisdiction shall not invalidate the remaining
provisions of the Maintenance and Repair Agreement.
7OWNER:
.y (signature)
G¢ 2. I(,.� (printname)
STATE OF ALASKA )
) ss.
THIRD JUDICIAL DISTRICT)
Date: -1 2
EL"O"RI
Public
OLSON Alaska
his My 16, 2036
The foregoing instrument was acknowledged before me this 2Q day of
20_�J,by -C 'Fic -i-- G/..
NOTARY PUBLIC FOR ALASKA
My Commission expires: M4400 aT2O M
MUNICIPALTTY:
By: (signature)
(print name)
Date: 1 J — C iSTitle:
11
Municipality of Anchorage
' Development Services Department
Building Safety Division
V -tlr%,•
On -Site Water BWastewater Program
4700 Bragaw Street
P.O. Box 196650
Anchorage, AK
www.muni.org/onsrg/onsrie
(907) 343-7904
CERTIFICATE OF ON-SITE SYSTEMS APPROVAL
FOR A SINGLE FAMILY DWELLING
Parcel I.D. t) I � -113'/3 COSA# D
1. GENERAL INFORMATION Expiration Date: /1— 3 — o ro
Complete legal description
Location (site address)
Current Property owner(s)
Mailing address
Lending agency
Mailing address
Real Estate Agent
Mailing address
FOREST RIDGE SUBDMSION: LOT 11, BLOCK 1
5201 BISHOPS CASTLE CIRCLE • ANCHORAGE. AK 99516
JEFF HENDRICKSON Day phone 344-3532
5201 BISHOPS CASTLE CIRCLE 0 ANCHORAGE, AK 99516
Unless otherwise requested, COSA will be held by DSD for pickup.
2. NUMBER OF BEDROOMS: 5
3. TYPE OF WATER SUPPLY:
Individual Well
0
Individual Water Storage
❑
Community Class Well
❑
Public Water System
❑
Day phone
TYPE OF WASTEWATER DISPOSAL:
Individual On-site
0
Individual Holding tank
❑
Community On-site
❑
Public Sewer
❑
The Municipality of Anchorage Development Services Department (DSD) Issues Certificates of On -Site Systems
Approval (COSA) based only upon the representations given In paragraph 4 by an Independent professional civil
engineer registered in the State of Alaska. Certificates of On -Site Systems Approval are required for the transfer
of title (except between spouses) for properties served by a single-family on-site wastewater disposal and/or
water supply system. DSD also Issues COSAs upon request to homeowners. Certificates of Onsite Systems
Approval are valid for 90 days from the date of issue for properties served by a private or Class C well and may
be reissued with new water samples. (Certificates may be reissued for a period of up to one year with valid water
samples.) Certificates are valid for one year for properties served by Class A or B wells or a public water system.
The Municipality of Anchorage is not responsible for errors or omissions in the professional engineer's work.
4. STATEMENT OF INSPECTION BY ENGINEER
As cerlified by my seal affixed hereto and as of the validation date shown below, I verify that my
investigation, based on procedures outlined in the Certificate of On -Site Systems Approval Guidelines for this application,
shows that the on-site water supply and/or wastewater disposal system is (are) safe, functional and adequate
for the number of bedrooms and type of structure indicated herein. I further verify that based on the
information obtained from the Municipality of Anchorage (les and from my investigation and inspection, the
on-site water supply and/or wastewater disposal system is(are) in compliance with all applicable Municipal
and State codes, ordinances, and regulations in effect at the time of installation.
Name of Firm GARNESS ENGINEERING GROUP, Ltd. Phone 337-6179
Address 3701 E. TUDOR ROAD, SUITE 101 • ANCHORAGE, AK 99507
Engineer's Printed Name JEFFREY A. GARNESS, P.E. Date 8 Z D
Engineers Comments:
In conducting this evaluation, GEG, Lt D. attempted to provide a thorough,
conscientious engineering analysis of the system In accordance with ADEC and MOA
DSD Guidelines 8 Regulations. The reported results described the performance of the
system under the conditions encountered at the time of the test, and separation
distances measured to readily identifiable features. The operational life of all wells and
septic systems depend on the local sods condition, groundwater levels that may
fluctuate during the year, and the water usage of the family being served by the system.
These conditions are outside the control of the evaluator of the system. Satisfactory lost
results do not guarantee future performance of the system, nor do they guarantee that
there are no hidden defects or encroachments. GEG, LTD. can therefore not provide
any warranty or future estimate of how long the system will continue to meet the
operational requirements of the ADEC or MOA DSD. The content of this report Is for
the sofe benefit of the owner listed above. Any reliance upon or use of this report by any
other person or party is not authorized, nor will it confer any legal right whatsoever.
5. DSD SIGNATURE
Approved for 57 bedrooms.
Disapproved.
Conditional approval for bedrooms, with the fllowing stipulations:
Attachments:
COSA Checklist
Septic System Advisory
Well Flow Advisory
Nitrate Advisory
Arsenic Advisory
Maintenance Agreements
Supplemental Engineer's Reort
Other
• N SIiE �•••'�
• WATER AN
WSpTEWpT�ER:
PROG •:
By: Original Certificate Date: S-3-06
IRr f�ARI
....PE
.........
13
.ess:
-79P
Conditional approval for bedrooms, with the fllowing stipulations:
Attachments:
COSA Checklist
Septic System Advisory
Well Flow Advisory
Nitrate Advisory
Arsenic Advisory
Maintenance Agreements
Supplemental Engineer's Reort
Other
• N SIiE �•••'�
• WATER AN
WSpTEWpT�ER:
PROG •:
By: Original Certificate Date: S-3-06
IRr f�ARI
Municipality of Anchorage
Development Services Department
Buikflng Safety Division .
Onsite Water 6 Wastewater Program
4700 Bragaw Street
P.O. Box 196650
Anchorage, AK 99519 -MM
www.muni.orglonske
(907) 3437904
CERTIFICATE OF ON-SITE SYSTEMS APPROVAL CHECKLIST
Legal Description: FOREST RIDGE SUBDIVISION: LOT 11. BLOCK 1 Parcel ID: _0 /7- 113 - / 3
A. WELL DATA
Well hype _iBNe7 If A, B. or C provide PWSID# N/A
Date completed 4/13/2001 Sanitary seat (YM) YES
Total depth 73 ft. Cased to 73 ft.
FROM WELL LOG
Date of test 4/13/2001
Static water level 31 R.
Well production 30 9.p -m.
WATER SAMPLE RESULTS:
Web Log (Y/N) YES
Wires property Proteded (Y/N) YES
Casing height (above ground) 1 S+ in,
AT INSPECTION
7/21/2006
27 ft.
5.12 g.p.m.
Coliform _ 0 cotonles/100 ml. Nitrate _Nf2_mgA. Other bacteria_ 0 colonies/100 mi.
Arsenic: NO ugA. Date of sample: 7/21/2008 C ilected by: GEG. Ltd.
B. SEPTIC(HOLDING TANK DATA 'WILL BE PUMPED AS NEEDED UNDER ADVANTEX
MAINTENANCE CONTRACT
Tank Type/Matarlal _ AOVANTEX/STEEL Date installed 6/7-27/2001
Tank size 2000 gat. Number of Compartments 2 Cleanouts (Y/N) YES
Foundation deanout (YM) YES Depression over tank (Y/N) NO High water alarm (YM) YES
Date of pumping ' Pumper A+ HOME SERVICES
C. ABSORPTION FIELD DATA 16SELOW EX
Date installed 6/7-27/2001 Sop rating (g.p.dJfl t rr 2_0 System type BIS
Length 40/40 ft. Width 10/10 ft. Gravel below pipe 0.70 ft,
Total depth 2.83+ IL Elf. absorption area 400 400 ftr Monitoring tube YES Depression over field NO
Date of adequacy test 7/21/2006 Results (Pass/Fall) PASS For 5 bedrooms
Fluid depth in absorption field before test RY DRY in. Water added 760 gal. New depth4.5 4.5in.
Elapsed Time: 324 min. . Final fluid depth DRY,/D in. Absorption rate >= 750+
g.pA.
Any rejuvenation treatment (past 12 mo.) (Y/N 3 type) NONE KNOWN If yes, give date —
D. LIFT STATION
Date installed Size in gallons
"Pump on" level at _in. "Pump ofP�t ----
0.' High water alarm level at in.
Cycles tested Meets alarm 8 circuit requirements?
E. SEPARATION DISTANCES
SEPARATION DISTANCES FROM WELL ON LOT TO:
Septic tank/ldt station on lot 100'+ On adjacent kNs 100'+
Absorption field on lot 100'+
Public sewer main N/A
Sewer /septic service line 25'+
On adjacent kits 100'+
Public sewer manhole/cleanout N/A
Holding tank N/A
Animal containment areas 50'+ Manure/animal excrete storage areas 100'+
SEPARATION DISTANCES FROM SEPTIC/HOLDING TANK ON LOT TO:
Building foundation 5'+ Property line 5'+ Absorption field 50+
Water main N/A Water service line 10'+ Surface water 100'+
Wells on adjacent lots 100'+
SEPARATION DISTANCE FROM ABSORPTION FIELD ON LOT TO:
Property line 10'+ Building foundation 10'+ Water main N/A
Water service line 10'+ Surface water 100'+ Driveway. parkingtvehide storage 10'+
Curtain drain NONE KNOWN Wells on adjacent k is 100_+
F. COMMENTS
G. ENGINEER'S
I certily that I have determined through Held inspections and
review of Municipal records that the above systems are In
conformance with MCW COSA guidelines in effect on this
date.
Engineer's Printed Name JEFFREY A. WNL
Date a/i/°6
COSA Fee E c130. UU f l %5• cx)
Date of Payment �31/0 (-
Receipt
Receipt Number 7
(nN. iI=)
Waiver Fee E
Date of Payment
Receipt Number
98-29
FOREST RIDGE SUBDIVISION
LOT 11, BLOCK 1
42,806 S.F.
WOODHAVEN AVE.
0
n
N 89048'11"E 166.03'
10' T. do E. ESMT.
------------------
I
I
I LOT 11
t
I
I
I
I
I
I
I �y
U) I
7`1 EXISTING
e O
'I
tNo I BUILDING
(SEE MAL) s%.n•
r*i in WELL
w I ■
cl
I
I SEp% SISTE+
I
- - .4
40' SEPTIC SETBACK
Cb
A3 4 42.-1v
AS-
GASTALDI LAND SURVEYING
JEFF A. GASTALDI, R.L.S.
4726 WEST 88TH AVENUE
ANCHORAGE, ALASKA 99502
PHONE 248-5454
GRID DATE
3137 10/1/2001
F.B. JOB NO.
01-07 FRS111
I HEREBY CERTIFY THAT I HAVE SURVEYED THE
PROPERTY DEPICTED ABOVE AND THAT NO
ENCROACHMENTS EXIST EXCEPT AS INDICATED.
IT IS THE RESPONSIBILITY OF THE OWNER TO
DETERMINE THE EXISTENCE OF ANY EASEMENT;
COVENANTS OR RESTRICTIONS WHICH DO NOT
APPEAR ON THE RECORDED SUBDIVISION PLAT,
UNDER NO CIRCUMSTANCES SHOULD ANY DATJ
HEREON BE USED FOR CONSTRUCTION OR FO
ESTABLISHING BOUNDARY OR FENCE LINES.
ANCHORAGE RECORDING DISTRICT, ALASKA
NOTE: NO CORNERS SET THIS DATE.
fA
ri
N
W
O
O
O
O
O
O
II
1 11=40'
BUILDING DETAIL
SCALE: 111=20'
OF q
i ,k 49111 •: A
r ...............,....«
Jeffery A. Gostoldl : o`
t •., r LS -6091 .f �oa•
o
�p ••.....•••• `'
a
�tos$Iona%va
'♦� ti t1***•