On -Site Wastewater Disposal System and/or Well Inspection Report
Permit Number. SW980083 PID Number 068-041-11
of 3
Name. THOMAS VICKREY
Wastewater System: ■ New • Upgrade
Address:
20021 NEW ENGLAND * EAGLE RIVER, AK 99577
ABSORPTION FIELD
Phone: No. of Bedrooms:
(907) 696-8354 4
■ Deep Trench D Shallow Trench O wed Olbund DOther
LEGAL DESCRIPTION
ora Mang: 1.2 my% R.
Tem Depth �'" reload
6 7.65 rte
Lot: BI«k: Subdivision:
D.prh b Pk* bottom from .4ganot grddc
Grave depth beneath
5 2 OVERLOOK ESTATES
1.33-2.38 n
'Mc
5.27 n
Township: — Range•. — Section:
1 added above enrol grad.
2.0-3.0 n.
Crawl lama.
60 rt
Gravel etdha
*mar Mem
WELL: ■ New ❑ Upgrade
2.5 R
al
1
Nutmeg b.bwn ens
— fe
o..a.oton (Prt.el.. &a.Ck
PRIVATE
Total Depth:
260 ft
Cored T.
86.96 ,t,
TOW ebearpaon arum
632 so. ft.
Pp maWbt
D 3034/ F-810
Mien
s 1.
M
M—W DRILLING
5/27/98
2 0 n.
K.C. ALASKA INC.
Date Instals*
6/8/98
rwx
1.0 Gni
Parry set At
U.K rt
Corkq Wont More Ground:
24• ft.
TANK
SEPARATION DISTANCES
■septic Molding OS.T.E.P. DOther
To
From
septic
Tank
Absorption
Field
Uft
Station
Holding
Tonk
PWip/praate
S..« un..
Y01M1fOC�`r'
ANCHORAGE TANK
Coperp m poking
1250
lou of
*mer a
Well
100'+
100'+
—
—
25'+
STEEL
conga bncAc
2
Surface Water
100'+
1001+
—
—
-
LIFT STATION
Lot Line
5'+
10'+
—
—
—
Ste
N`• In plenate.wraetorr:
Foundation
5'+
10't
—
—
—
'pump pre .s et
-en err et
met miter stem at
~'°p Sol
s1pi90ne
Curtain Drain
NONE
KNOWV
r«nrnwe by:
Remarks:
BENCH MARK
Location and D.wgtbn:
BOTTOM OF SEPTIC TANK ON OUTLET END
Mead Dewar
95.02 n
amours seAt
000A604p0.;;/
GT& . -.4; %
Inspections performed by' AWWC, INC. Dates: 1st 6/8/98
I 4E' SP......% .
2nd 6/8/98
.
's if .140
•
/7ed'-i. .times
Department of Health red H • n ervices approve
and approved by Dien• Date /'l7 f OzOpppOOp��t�oov
4�a C •795 `4:
Dim 1=e/wed
Municipality of Anchorage
t •e.. _�•
• 1� Development Services Department •_ :
1 Building Safety Division
On-Site Water & Wastewater Program, 4700 South Bragaw St.
P.O. Box 196650 Anchorage, AK 99519-6650
www.d.anchorage.ak.us (907)343-7904 Page 1 of 3
Onsite Wastewater Disposal System and/or Well Inspection Report
Permit Number. SW980083 PID Number. 068-041-11
Name:
THOMAS VICKREY
Wastewater System: ■ New 0 Upgrade
Address:
20021 NEW ENGLAND * EAGLE RIVER, AK 99577
ABSORPTION FIELD
Phone: No. of Bedrooms:
(907) 696-8354 4
■Deep Trench OShallow Trench OBed OMound OOther
LEGAL DESCRIPTION
S""abic 1.2 mist,. rt.
Total Depth fromeddied
s 7.65 a
Lot Block: Subdivision:
Dean, b bottom ham
Gravel dept, beneath
5 2 OVERLOOK ESTATES
Piro algid grade:
1.33-2.38 n.
pipe•.
5.27 re
Township: _ Pangs: _ Seaton:_
oboes . added oboes congaed grade
2.0-3.0 re
Gravel WON—
60 n.
WELL: ■ New 0 Upgrade
Grant wont:
2.5 n,
Number anon
Distance between In..
of
1
— R
Cb.HM1cauw, (what.. A9.C):
PRIVATE
Tobi Depth:
260 n
Cooed To:
86.96 ,
Told eb.apton ane:
632 so. n
Pipe material:
D 3034/ F-810
Onion
M—W DRILLING
Date DSC
5/27/98
stab water Levet
240 n.
Intoner:
K.C. ALASKA INC.
ode IMabot
6/8/98
Telt
1.0 rsu
Pump set At
U.K n,
Cooing Hart Abed. Grout
dee8 INCHES n.
TANK
SEPARATION DISTANCES
■Septic 0Holding 0S.T.CP. OOther
To
From
Septic
Tank
Absorption
veld
Litt
Station
Holding
Tank
hiwwicet'aa
C•podty I,
Public/Private
Sew lone
ANCHORAGE TANK
goMoac
1250
Well
1001+
100'+
—
—
25'+
lealsoot
STEEL
M Number
of oangaunanb: 2
Surface Water
100'+
100'+
—
—
—
LIFT STATION
Lot Line
5'+
10'+
—
—
—
Sue In dolma
Ya Mostar:
Foundation
51+
10'+
—
—
—
"Pump en NS et
'P,mp err at
lbph water dorm at:
Curtain Drain
KNOW�'I
Pump la..
Electrical Iwveatbn
performed tret
NONE
Remarks:
BENCH MARK
loo.ton
—
PROPERTY OWNER WAS NOTIFIED IN JULY OF 2001
REGARDING THE NEED TO EXTEND THE CASING.
cad P..alpbwa
BOTTOM OF SEPTIC TANK ON OUTLET END
—
AWWC, INC. RECOMMENDS THAT THE MOA RETAINS
THE INSPECTION REPORT UNTIL THE SUBJECT
REPAIR IS MADE.
95.02
n.
;�
IHGMEEXS
od�40�
gra pF
SEAL
Op
e..* ':•4
Inspections performed by AWWC, INC. Dates: 1st 6/8/98
2nd 6/8/98
if
Department of Health and Human Services approval
Reviewed and approved by Date
Ott,
0���
OQbk‘‘<:(4°4.14.--
fey . •• s; 0
1
., C. 7953 : ; ,e;d
tPo\S'
(nee. 12/00)
PERMIT NUMBER:
SW980083
ST1
ST2
DBL1
DBL2
C01
MT1
CO2
MT2
A
AS -BUILT DRAWING
,
40-
70.62
78.66
81.64
84.30
90.31
107.34
138.21
137.00
B
68.05
76.36
79.36
81.95
87.92
101.57
129.22
128.01
NEW 1250 GALLON
SEPTIC TANK
Cs.
'c i" . `
•
N. 'C r.N
ALTERNATE SITE
O1
DATE:
7/11/2001
ALASKA WATER & WASTEWATER
CONSULTANTS, INC.
6901 DEBARK ROAD, SIAM 213 • ANCHORAGE, A% 99504 • MORE (907)337-0I79 • FAX (907U16J246
DRAWN BP
C.J.G.
SCALE:
1"=40'
PREPARED FOR: PHONE NUMBER:
THOMAS VICKREY (907) 696-8354
PAGE NUMBER:
20F3
LEGAL DESCRIPTION:
OVERLOOK ESTATES SUBDIVISION; LOT 5, BLOCK 2
TYPE OF WORK:
AS -BUILT DRAWING OF SEPTIC SYSTEM UPGRADE
PARCEL ID NUMBER:
068-041-11
NEW DRNNFlEID
PERMIT NUMBER;
SW980083
AS—BUILT DRAWING
PARCEL ID NUMBER:
068-041-11
TOP OF TANK A
INLET - 100.00
FINAL00-
104.00+
INVERT OF BUNG
AT INLET - 99.42
TOP OF TANK AT
OUTLET - 99.90
INVERT OF BUNG AT
OUILET - 99.15
FINAL GRADE
- 103.7 +/—
RIGINAL GRADE -
100.31-101.38
FILTER FABRIC
INVERT OF PIPE
- 98.98
BOTTOM OF
TRENCH - 93.71
ALASKA WATER & WASTEWATER
CONSULTANTS, INC.
6901 0EBARR ROAD. SUITE 78 • ANCHORAGE. M 99504 • PHONE (907)337-6179 • FAX (901)3384246
DATE:
7/11/2001
DRAWN BY:
C.J.G.
SCALE:
N.T.S.
PREPARED FOR: PHONE NUMBER:
THOMAS VICKREY (907) 696-8354
PAGE NUMBER:
3 OF 3
LEGAL DESCRIPTION:
OVERLOOK ESTATES SUBDIVISION; LOT 5, BLOCK 2,
TYPE OF WORK:
PROFILE AS -BUILT DRAWING OF SEPTIC SYSTEM
0
0/3 •
°°u ••• •.......•
�1;y8e;'oT9es1D00��cd
‘\\400000.„e.
07/05/2001 17:10 3453287
M W DRILLING, INC
Pt -W DRILLING, INC
P 0 BOX 110378
ANCHORAGE, AK 99511-0378
345-4000 FAX 345-3287
MAtU HU WOAD
PAGE 01
W7Il101 TIL
Eta
0112at16Y
S01DM1I011
MOW tffhfl7
10?
5
(LOCI
1
$EC11011 Q?R3
St/101
701150?
1AA01
I=ll
LOU21211001:
1E41 UM
11040 Itillt
.101101 MUG Min
MI RNA ISM
DIMS WNW Ito: (111 CASDK tOP [ J CROOID SOME
HELL &S-111ft: UT: OI C81U71OE
DEPT Of IOU: 10 Int
EMU 17l: DM
UW11L MI COO PROM T4
omi Of MC: sum
CLOG STIQOP
0
1
DEM TO STATIC UM UM:
LRAP/S: STD COu111
1
CM
out 05/19/91 no R uta (a 70 Ot cum [ 1110010soma ;
CM= Mtf CIT
K
X
CUM Mt: MU DILL 111. NU 1 74 WI 17
1111 UPL UA DIAL ICOM 70 K
S1MWIT LW WI MN V11/1 LAW
117
W
ZfSMD WS WT HUM IO'US
T7AIOMTI0& 1/A t0 11
21(
10
SCIE01 Mt 1/A Dia:
LOVES! MD_1001: a
QUICK FA. ' IL . •
lianiEgIN
PAC1 t7Pt MEL
1211127, 2.
rom: WOW RT
-
Wit • OSLO:
MUNE OSLO: 1,11170 70P
f ii -Ars(( •.N' imiez
r
i�iim ri :.'111.1!1�.''a
- Roo f tti r"----&OKL 2 :I -
DEPTH: TRON r to
_mammon
-- ___- —.
'
-
.. i
ilal1 . .. !l. r J
4.11111
M u . moil ,� 5i 'l .Il f� 7i
r
•
10ti a
•
"
' IOPILI
of Of Of YtLL MzsT�I (] tt0A112 [ 1 10111101 [ 1(NILS
1 OUP - ' --
'
D,vNt6P�[71oa: 407sa '
RUTIN: 11001 AMR 1100 VD XXX SIIL NIX 10P1
T111C UM IN M.
inn HOOKS PORN CPM
—ft
OMP DRAB, DRP7t
I,LL morn OKI CO UTION (1:11111 ( 110
—nit
HAMS:
1-YKLUX DID101ASfILt IMO i1Ef RSL
•
••
NWWA CarHtfad Contractor
Alaska Water & Wastewater Consultants, Inc.
6901 Debarr Road, Suite 2B, — Anchorage — Alaska 99504
Phone (907) 337-6179 — Fax (907) 338-3246
June 9, 1999
Municipality of Anchorage
Department of Health & Human Services
P.O. Box 196650
Anchorage, AK 99519-6650
Attn: Laura Montgomery
REFERENCE: Lot 5; Block 2; Overlook Estates
Status of septic system documentation
RECEIVED
ry�u'IcJUN 11 1999
wept. Health �$ Human Anchorage es
A permit (#SW980083) was issued to install the referenced septic system 4/29/98. The
septic system was installed 6/98, however the proposed house construction was canceled.
When a house is eventually constructed on the property, I will complete the
documentation and as -built of the septic system which will be submitted to your
department (DH -IS) for review and approval. If you have any questions, please contact
me at 337-6179 or 244-9612.
Thank you for your istance.
ly
Jeffr:�
Presiden
JAG/gd
ess,., M.S.
F ck Alysfrom,
&favor
l rnlicipalit of Anchorage
Department of Health and Human Services
825 "L" Street
P.O. Box 196650 Anchorage. Alaska 99519-6650
http:6www.ci. anchorage.aa.us
April 29, 1999
Thomas H & Ellen K Vickery
PO Box 771298
Eagle River, Alaska 99577 1298
Subject: Lot 5 Block 2 Overlook Estates Subdivision
Permit # SW980083 PID # 068-041-11
The subject permit, issued April 29, 1998 by this office for a single family well and/or on-
site wastewater system, has expired as of April 29, 1999.
A new permit must be obtained from this office for a well and/or on-site wastewater
system NOT installed by the expiration date.
If you have drilled the well, a well log must be sent to this office for documentation of the
installation and to close the permit.
If a licensed Professional Engineer has inspected the installation of the on-site wastewater
system, the original as -built inspection report must be sent to this office for review,
approval and documentation. All inspection reports must be submitted within 30 days of
construction completion.
When applying for a new permit, the fees are: $320.00 for an on-site wastewater permit;
$120.00 for a well permit and $440.00 for a combined on-site wastewater and well permit.
If you have any questions, please call this office at 343-4744.
James Cross, PE
Program Manager
On-site Services
enc: Copy of Permit
Page: 1 Document Name: ENTERPRISE SERVER
PARCEL: 068-041-11-000-00 CARD: 01 OF 01 RESIDENTIAL VACANT LAND
STATUS: RENUMBERED TO/FROM: 000-000-00-000-00
VICKREY THOMAS H & ELLEN K
PO BOX 771298
EAGLE RIVER
OVERLOOK ESTATES
BLK 2 LT 5
AK 99577 1298 SITE 27509 PARAMOUNT DR
LOT SIZE: 53,567
ZONE : R10
TAX DIST: 030
GRID
NOTES : REF 050--381-31
---DATE CHANGED ---
OWNER : 04/02/97
ADDRESS: 07/28/98
HRA # : 000000
FINAL VALUE 1997:
FINAL VALUE 1998:
FINAL VALUE 1999:
EXEMPT VALUE 1999:
STATE EXEMPT 1999:
FINAL VALUE 1999:
49,000
52,700
52,700
0
Date: 4/29/99 Time: 07:39:48 AM
ASSESSMENT HISTORY
----DEED CHANGED ---
BOOK : 3041 PAGE:
DATE : 03/26/97
PLAT : 840287
--BUILDING- ---TOTAL---
0 49,000
0 52,700
0 52,700
0 0
0
52,700
--EXEMPTION
TYPE --
-COMM COUNC
EAGLE RIVER
Alaska Water & Wastewater Consultants, Inc.
7320 East Chester Heights Circle — Anchorage — Alaska 99504
Phone (907) 337-6179 — Fas (907) 338-3246
September 1, 1998
Municipality of Anchorage
Department of Health & Human Services
P.O. Box 196650.
Anchorage, AK 99519-6650
Attn: Laura Montgomery
REFERENCE: Lot 5; Block 2; Overlook Estates
Status of septic system documentation
RECEIVED
SEP 21998
Municipality of Anchorage
Dept. Health & Human Services
A permit (#SW980083) was issued to install the referenced septic system 4/29/98. This
property is undeveloped and a new home is being built. The septic system has been
installed, however there are no points of reference to swing -tie the new septic system on
the property. Alter the house is complete, or an as -built survey is done, I will complete
the documentation and as -built of the septic system which will be submitted to your
department (DHHS) for review and approval. If you have any questions, please contact
me at 337-6179 or 244-9612.
Thank you for your assistan
Sinc
Jefire
Presiden
JAG/gk
Alaska Water & Wastewater
7320 East Chester Heights Circle — Anchorage — Alaska 99504
Phone (907) 337-6179 — Fax (907) 338-3246
July 30, 1998
Municipality of Anchorage
Department of Health & Human Services
P.O. Box 196650
Anchorage, AK 99519-6650
Attn: Laura Montgomery
REFERENCE: Lot 5; Block 2; Overlook Estates
Status of septic system documentation
RECEIVED
AUG 13 1998
Municipality of Anchorage
Dept. Health & Human Services
A permit (#SW980083) was issued to install the referenced septic system 4/29/98. This
property is undeveloped and a new home is being built. The septic system has been
installed, however there are no points of reference to swing -tie the new septic system on
the property. After the house is complete, final grading is done and an as -built survey is
done, I will complete the documentation and as -built of the septic system which will be
submitted to your department (DHHS) for review and approval. If you have any
questions, please contact me at 337-6179 or 244-9612.
Thank you for your assis : nce.
Since
Pri ip
JAG/gk
ess, ' M.S.
PAGE
MUNICIPALITY OF ANCHORAGE
DEPARTMENT OF HEALTH AND HUMAN SERVICES
P.O. BOX 196650, 825 "L" STREET, ROOM 502
ANCHORAGE, ALASKA 99519-6650
ON-SITE WELL AND WASTEWATER DISPOSAL SYSTEM PERMIT
PERMIT NUMBER:SW980083 DATE ISSUED: 4/29/98
DESIGN ENGINEER:ALASKA WATER & WASTEWATER SERVICES EXPIRATION DATE: 4/29/99
OWNER NAME:VICKREY THOMAS H & ELLEN K
OWNER ADDRESS:20021 NEW ENGLAND DRIVE
EAGLE RIVER, ALASKA 99577
PARCEL ID:06804111
LEGAL DESCRIPTION:
OVERLOOK ESTATES BLK 2 LT 5
LOT SIZE: 53567 (SQ. FT.)
NUMBER OF BEDROOMS: 4 THIS PERMIT: 4
THIS PERMIT IS FOR THE CONSTRUCTION OF:
DISPOSAL FIELD /SEPTIC TANK / WELL SYSTEM
ALL CONSTRUCTION MUST BE IN ACCORDANCE WITH:
1. THE ATTACHED APPROVED DESIGN.
2. ALL REQUIREMENTS SPECIFIED IN ANCHORAGE MUNICIPAL CODE CHAPTERS
15.55 AND 15.65 AND THE STATE OF ALASKA WASTEWATER DISPOSAL
REGULATIONS (18AAC72) AND DRINKING WATER REGULATIONS (18AAC80).
3. THE ENGINEER MUST NOTIFY DHHS AT LEAST 2 HOURS
PRIOR TO EACH INSPECTION. PROVIDE NOTIFICATION BY
CALLING 343-4744 ( 24 HOURS ) . (NOT REQUIRED FOR WELL ONLY PERMIT)
4. FROM OCTOBER 15 TO APRIL 15 A SUBSURFACE SOIL
ABSORPTION SYSTEM UNDER CONSTRUCTION DURING FREEZING
WEATHER MUST BE EITHER:
A. OPENED AND CLOSED ON THE SAME DAY
B. COVERED, SEALED AND HEATED TO PREVENT FREEZING
5. THE FOLLOWING SPECIAL PROVISIONS.
SPECIAL PROVISIONS:
RECEIVED BY:
ISSUED BY:
DATE:
DATE:Q 29 98
Alaska Water & Wastewater
7320 East Chester Heights Circle -- Anchorage — Alaska 99504
(907) 337-6179 -- Fax (907) 338-3246
Consulting Engineers
April 12, 1998
Municipality of Anchorage
Department of Health & Human Services
Division of Environmental Services
On -Site Services Section
P.O. Box 196650
Anchorage, Alaska 99519-6650
+���\\\l
�
i :tomP'•
/ phi
7933
IW/
f • Att.,
�F9�''•.a....r' +
ibON.vwd 5r -
Ref: Well & Septic System for Lot 5, Bk 2, Overlook Estates S/D. Eagle River, Alaska.
To whom it may concern:
The subject property is currently undeveloped. The owners are proposing to construct a four
bedroom house, which will require the installation of a well and a septic system. Comments
regarding the proposed design are summarized as follows:
1. SOILS: Attached is a copy of the soil log. The soil below the organic/loam layer was a
gravelly sandy soil, with small cobbles, and numerous thin layers of sand. The percolation rate of
the soil, at a depth of 4.5.- 5.0 feet was less than 1 minute/inch. Based upon my visual
observation, the soils throughout the test hole depth appeared to be in the 1-5 minute/inch range,
and there appeared to be enough thin sand lenses to justify not using a sand filter. The sidewalls
of the test hole were stable (no sloughing) indicating that there was enough fines to serve as a
binder. It is my recommendation that a deep trench be installed. Neither of the septic systems on
the adjacent Tots utilize sand filters. Regardless, if your department deems it to be necessary, we
can install shallow trenches, with sand filters. Attached is a design drawing for either option. The
specifics of the deep trench design are summarized as follows:
2. TRENCH DESIGN:
a. Percolation Rate: <1 minutes/inch.
b. Allowable Application Rate: 1.2 gallons/day/ft2
c. Number of Bedrooms: 4
d. Design Flow: 600 gallons per day
e. Minimum Absorption Area: 500 ft2
f. Total depth: 8 feet
g. Effective Depth: 5.0 feet )
h. Reduction Factor = N/A
i. Width: 2 feet minimum
j. Minimum Length: 50 feet
k Effective absorption area = 500 ft2
3. SURFACE WATERS: There are no surface waters within 100 feet of the proposed septic
system.
4. TOPOGRAPHY: The lot slopes 15%-20% downhill, from north to south, at the proposed
trench sites. At the south end of the lot, near the road cutbank, the slope transitions to greater
than 100%. There are no slopes, downhill, and within 50 feet of the trenches, that are greater
than 25%. In short, there are no slope concerns.
I am unaware of any adverse impacts this installation would have on adjacent wells or septic
systems. If you have any questions, please contact me at 337-6179, or 244-9612. Thank you for
your assistance.
Sincerely,
Jeffr • . j arness, P.E., M.S.
Princi.al
rPROPCSED
PROPOSED 4 BED
HOUSE LOCATIO
LOT 4, OVERLOOK
ESTATES
XISTING SEPTIC
LOT 6, OVERLOOK
ESTATES
POSED SEPTIC AREA
NOTEJ THIS IS NOT A SURVEY. THE LOCATION OF ALL WELLS, SEPTIC SYSTEMS.
AND STRUCTURES IS APPROXIMATE. THE CONTRACTOR SHALL VERIFY THE SEPARATION
DISTANCE FROM THE SEPTIC SYSTEM UPGRADE TO ALL VEILS ON ADJACENT LOTS.
SEPTIC UPGRADE' LOT 5, BK 2, OVERLOOK ESTATES
PREPARED FORA TOM VICKERY
PREPARED BY' ALASKA WATER 8 WASTEWATER
DATE' 3/4/98 I DRAWN: WILLIAMS I SCALES 1' = 100'
"-PROPOSED YELL LOCATION
THE CONTRACTOR SHALL BE RESPONSIBLE FOR HAVING
THE LOT LINES ADJACENT TO THE SEPTIC SYSTEM
FLAGGED BY A REGISTERED LAND SURVEYOR. THE
ENGINEER WILL MAKE TO ATTEMPT TO LOCATE THE LOT
LINES DURING THE INSTALLATION OF THE SEPTIC SYSTEM.
PROPOSED 4
BORN HOUSE
PROPOSED 1250 GALLONI•.;°:.".,
SEPTIC TANK
SEVER LINE UNDER DRIVEWAY
ITH 4 INCHES OF BOARD I
MINIMUM SOIL COVER SHALL B
ROPOSED TRENCH
HALL BE INSULATED
ATION (4 FEET VIDE). THE
3 FEET.
❑PTI❑N I
Fc,,
SEPTIC UPGRADE: LOT 5, BK 2, OVERLOOK ESTATES
PREPARED FOR: TOM VICKERY
PREPARED BY: ALASKA WATER Is WASTEWATER
DATE: 4/98
IDRAWN: WILLIAMS I SCALE: 1' = 30'
ZI
f'•1./ 1 A. Car s;
C —7953
•' •d�
oi' • ...... • '•'ts.
t'
`-PROPOSED VELL LOCATION
THE CONTRACTOR SHALL BE RESPONSIBLE FOR HAVING
THE LOT LINES ADJACENT TO THE SEPTIC SYSTEM
FLAGGED BY A REGISTERED LAND SURVEYOR. THE
ENGINEER WILL MAKE TO ATTEMPT TO LOCATE THE LOT
LINES DURING THE INSTALLATION OF THE SEPTIC SYSTEM.
PROPOSED 4
BDRM HOUSE
ZABEL FLOW
SPLITTER
PROPOSED 1250 GALLON( • % .".,
SEPTIC TANK
• I
DOUBLE C/O'S
OPTION II
SEVER LINE UNDER DRIVEVAY .HALL BE INSULATED
ITH 4 INCHES OF BOARD INS ATION (4 FEET VIDE). THE
MINIMUM SOIL COVER SHALL B1 3 FEET.
PRIMARY TRENCHES. 60
FEET LONG EACH
RESERV
ENCHES
THE TRENCHES SHALL BE 5' WIDE/
AND HAVE A MAXIMUM DEPTH OF 7
FEET. PLACE A 2 FOOT SAND
FILTER. 6 INCHES OF DRAINROCK
BELOW THE PIPE INVERT.
SEPTIC UPGRADE: LOT 5, BK 2, OVERLOOK ESTATES
PREPARED BY: ALASKA WATER & WASTEWATER
DATE: 4/98 I DRAWN: GARNESS J SCALE: I' = 30'
ss;
E-7953
VAtorseeUAe eco
Municipality of Anchorage
DEPARTMENT OF HEALTH & HUMAN SERVICES
825 "L" Street, Anchorage, Alaska 99502-0650
SOILS LOG - PERCOLATION TEST
PERFORMED FOR: 'TO 14 VI�/F-eszy D:4 - Eon sk's Ems
DATE PERFORMED: �OFc� 5410�� /
BK 2\MyM1�I�
LEGAL DESCRIPTION: LOT S OVf LDoK- ES Township, Range. Section: 14A' 1A - Q
24. " C:12 .4
SLOPE SITE PLAN
1
2
3
4
5
6
7
8
10
11
12
13
14
15
16
17
18
19
20
` •s
•,0 •♦
• 0
o •
•
0'
.
o a•
„
s
•
o a
n• .s
e
0
.
.
0•
.0, 0•
COMMENTS
le 4., slit/Loavyl
sch4Dy CO.Avet r/
SOIL. L m-% NN1'+EaouS
cbeeLF-S � 5n -on
L�aSES erl-t.4)
WAS GROUND WATER
ENCOUNTERED?
IF YES, AT WHAT
DEPTH?
. S
L
N /4 O
Depth war AAn—tet 4
/14Aa
Monibrinp) Dalt
t
N
Sae
CA-
LE
SI
LMI
Reading
Data
Gross
Time
Ne
Time
Depth to
Water
Net
Drop
NM
Pt2esoo-tc
QapvIRE.fl
1-
5/6%417-
en" -c
1 A4?Atta-ES
PERCOLATION RATE (minutesnnch) PERC HOLE DIAMETER
TEST RUN BETWEEN �" S FT AND S' FT
EXCELLexor SatL
Nc5
PERFORMED BY Er -e- CiLa.JeSS I SE -F - Gagea--3 S CERTIFY THAT THIS TE T WAS PERFORMED IN
ACCORDANCE WITH ALL STATE AND MUNICIPAL GUIDELINES IN EFFECT ON THIS DATE. DATE' 4114-�9 8
72-008 (Rev. 4185)
Municipality of Anchorage
Development Services Department
Building Safety Division
On -Site Water and Wastewater Program
4700 Elmore Road
P.O. Box 196650
Anchorage, AK 99507
www.muni.org/onsite
(907) 343-7904
CERTIFICATE OF ON-SITE SYSTEMS APPROVAL
FOR A SINGLE FAMILY DWELLING
COSA# 4s L' j2,toco'
Parcel I.D. 068-041-11
1.
Eac
Expiration Date: 6 - Lj
GENERAL INFORMATION
Complete legal description Lot 5, Block 2, Overlook Estates Su inion
Location (site address) 27509 Paramount Drive Eagle River, AK 99577
Current Property owner(s) Ross and Jana Henikman
Mailing address
Lending agency Day phone
Mailing address
Real Estate Agent Day phone
P.O. Box 771487 Anchorage, AK 99577
Day phone
Mailing Address
Unless otferi&fse requested, COSA will be held by DSD for pickup.
2. NUMBER OF BEDROOMS: Four(4)
3. ` :TYPE OF WATER SUPPLY:
Individual Well
Individual Water Storage
Community Class Well
Public Water System
TYPE OF WASTEWATER DISPOSAL:
✓❑ Individual On-site ❑✓
❑ Individual Holding Tank ❑
❑ Community On-site 0
0 Public Sewer 0
The Municipality of Anchorage Development Services Department (DSD) issues Certificates of On -Site Systems
Approval (COSA) based only upon the representations given in paragraph 4 by an independent professional civil
engineer registered in the State of Alaska. Certificates of On -Site Systems Approval are required for the transfer of
title (except between spouses) for properties served by a single-family on-site wastewater disposal and/or water
supply system. DSD also issues COSAs upon request to homeowners. Certificates of On -Site Systems Approval
are valid for 90 days from the date of issue for properties served by a private or Class C well and may be reissued
with new water sample results. (Certificates may be reissued for a period of up to one year with valid water
samples.) Certificates are valid for one year for properties served by Class A or B wells or a public water system.
The Municipality of Anchorage is not responsible for errors or omissions in the professional engineer's work.
MUMCP)AUTY (OF
o P .,
Development Services Department
On -Site Water & Wastewater Section
Parcel I.D. 068-041-11
Certificate of On -Site Systems Approval
Expiration Date
1. GENERAL INFORMATION
Complete legal description OVERLOOK ESTATES BLOCK 2, LOT 5
Location (site address) 27509 PARAMOUNT DRIVE, EAGLE RIVER, AK 99577
Current property owner(s) KEITH & CHRISTINA HOWARD
Mailing address
Real estate agent
Phone: 907-343-7904
Fax: 907-343-7997
F-2,5-- 2 r
Day phone
27509 PARAMOUNT DRIVE, EAGLE RIVER, AK 99577
2. TYPE OF DWELLING:
® Single Family (w/wo ADU)
❑ Duplex
❑ Multiple Dwellings (Single Family and/or Duplex)
3. NUMBER OF BEDROOMS:
4
Day phone
4. TYPE OF WATER SUPPLY:
TYPE OF WASTEWATER DISPOSAL:
Private Well
®
Private Septic
Water Storage
❑
Holding Tank
❑
Community Well
❑
Community
❑
Public Water System
❑
Public Sewer
❑
Waiver request for:
Distance:
Received by: Date:
COSA to be released to the engineer, unless otherwise requested by the engineer.
COSA Fee $
So
Date of Payment 5-- 1!;�?_2
Receipt Number 70 90 S
COSA# O5Ca1I'a`-11
Waiver Fee $
Date of Payment
Receipt Number
Waiver #
5. STATEMENT OF INSPECTION BY ENGINEER
As certified by my seal affixed hereto and as of the validation date shown below, I verify that my investigation, based
on procedures outlined in the Certificate of On -Site Systems Approval Guidelines for this application, shows that the
on-site water supply and/or wastewater disposal system is (are) safe, functional and adequate for the number of
bedrooms and type of structure indicated herein. I further verify that based on the information obtained from the
Municipality of Anchorage files and from my investigation and inspection, the on-site water supply and/or wastewater
disposal system is (are) in compliance with all applicable Municipal and State codes, ordinances, and regulations in
effect at the time of installation. I acknowledge that On -Site staff may visit the site to verify the information submitted.
Name of Firm FIRST WATER CONSULTING Phone 907-350-9566
Address 13030 SUES WAY, ANCHORAGE, AK 99516
Engineer's Printed Name CURTIS HUFFMAN, PE Date 5/14/2021
Comments: This investigation was completed in compliance with MOA guidelines, regulations,
and best industry practices / methods. The assessment of the condition of the well and septic
applies only to the conditions as of the day tested. The flow and absorption rates may change
due to subsurface conditions that may not be observed from the surface, changes in land use,
local soil characteristics, groundwater levels that may fluctuate during the year, quality of
construction (workmanship & materials), the water usage of the family being served by the
system and maintenance. The operational life of all well and septic systems are subject to
these various and dynamic characteristics and are outside the control of the evaluator of the A 0 `
well and septic system. Therefore, any estimate of how long a system will function satisfactory g�..' • •
for current or future occupants or guarantee that no unseen encroachments, deficiencies or49 r
discrepancies exist can be given by First Water Consulting & FWCS *' ... ... �r
/ . ... .. ......... /
.. .... ........ i
6. DSD SIGNATURE '• • Curtis Huffman
System #1 Approved for bedrooms ��F��
cjsl. CE 128991 •
System #2 Approved for bedrooms l)k�, p�114/� ROFESSO�
Disapproved
Conditional approval for bedrooms, with the following stipulations:
`l�\1Y OF
O .
��Ora-�►�_
WATER AND m
._V'ATER oz
J�� PRO �A�t!
//0'�/Ls
�'J��I�;SERV\G. -
Original Certificate Date: Z� 2
The Municipality of Anchorage Development Services Division (DSD) issues Certificates of On -Site Systems Approval (COSA) based only upon the
representations given in paragraph 5 by an independent professional civil engineer registered in the State of Alaska. The Municipality of Anchorage is
not responsible for errors or omissions in the professional engineer's work.
7. ATTACHMENTS:
COSA Checklist X Nitrate Advisory
Septic System Advisory Arsenic Advisory
Well Flow Advisory Other SeC`�o�gJr�Sty
Legal Description: OVERLOOK ESTATES BLOCK 2 LOT 5 Parcel ID: 068-041-11
If more than 1 septic system on lot: COSA Checklist # _of
A. WELL DATA
® Well log is filed with Onsite (or attached)
Date drilled 5/27/1998
Total depth 260 ft
Cased to 87 ft
® Sanitary seal is functioning correctly
® Wires are properly protected
Casing height (above ground) 18+ in.
Date of flow test for COSA 4/27/2021
Static water level at beginning of test 180 ft.
Well production at time of test 0.58 gpm
Comments
B. TANK DATA
Age of tank(s) 23. years
Tank type/material SEPTIC / STEEL
Measured operating fluid level in septic tank 48"
® Standpipes/foundation cleanout per record drawing
Date of pumping 3/24/2021 l
D. ABSORPTION FIELD DATA
Which system tested (date installed) 6/8/1998
® ALL standpipes present per record drawing
Total measured depth from grade 10.5 ft (max)
Measured depth to pipe invert from grade 5 ft (min)
❑ N/A — pressurized field
® Monitor tubes go to bottom of effective. If not, state
depth into effective
® Code -required soil cover over field
❑ System presoaked
(Required if vacant for greater than 30 days prior to
date of test)
Gallons introduced gallons
Comments/Deficiencies:
Structure served by this system _
Water storage tank volume 500 gallons
Well disinfected for coliform test? ❑ Yes ® Nc
® Coliform bacteria is Negative
Nitrate 0.561 mg/L E]Nitrate less than MRL (ND)
Arsenic ug/L ® Arsenic less than MRL (ND)
FkE
Collected bywr
Date of Sample 4/23/2021 '
C. LIFT STATION
❑ Required maintenance completed
Age of lift station _ years
Lift station material
Comments:
Adequacy test date 4/27/2021
Results N Pass For 4 bedrooms
Fluid depth prior to test 0 in
Water added 600 gal
New depth 1 in
Elapsed time <5 min
Final fluid depth 0 in
Absorption rate 600 gpd
Any rejuvenation treatment (past 12 months) N
If yes, enter date
E. SEPARATION DISTANCES
From Private Well on Lot to: (Please enter distances if less than required or if community well)
Septic Tank/Lift Station on Lot > 100'
® Yes
if No
Community Sewer Manhole/Cleanout > 100'
® Yes
if No
ft
® Yes
if No
Neighboring Tank > 100' ® Yes
if No
ft
Private Sewer/Septic Line > 25' ® Yes
if No
Absorption Field on Lot > 100' ® Yes
if No
ft
Holding Tank > 100' ® Yes
if No
Neighboring Absorption Fields > 100'
Water Service Line > 10'
® Yes
Animal Containment > 50' ® Yes
if No
® Yes
if No
ft
Manure/Animal Excreta Storage > 100'
Community Sewer Main > 75' ® Yes
if No
ft
® Yes
if No
From Septic/Holding Tank on Lot to: (Please enter distances if less than required)
Building Foundations > 10'
® Yes
if No
ft
Surface Water > 100' ® Yes if No _
Property Line > 5'
® Yes
if No
ft
Wells on Adjacent Lots:
Absorption Field > 5'
® Yes
if No
ft
Private Wells > 100' ® Yes if No _
Water Main > 10'
® Yes
if No
ft
Community Wells > 200' ® Yes if No _
Water Service Line > 10'
® Yes
if No
ft
If septic tank is under driveway comment below
From Absorption Field on Lot to: (Please enter distances if less than required)
Building Foundation > 10'
® Yes
if No
ft
If absorption field is under driveway comment below
Property Line > 10'
® Yes
if No
_ ft
Wells on Adjacent Lots:
Water Main > 10'
® Yes
if No
ft
Private Wells > 100' ® Yes if No —ft
Water Service Line > 10'
® Yes
if No
ft
Community Wells > 200' ® Yes if No
Surface Water > 100'
® Yes
if No
ft
F. ENGINEER'S COMMENTS
G. ENGINEER'S CERTIFICATION
I certify that I have determined through field inspections and review
of Municipal records that the above systems are in conformance
with MOA COSA guidelines in effect on this date.
Ak
TM. .... ....:
.....
• • • Curtis Huffman • ! •: • >�
CE 128991 •��
512 Essi .P��.�.-�,�
ft
ft
ft
ft
ft
ft
ft
ft
MUNICIPALITY OF ANCHORAGE
DEVELOPMENT SERVICES DEPARTMENT a
On -Site Water and Wastewater Section
www.muni.org/onsite
Septic Tank Advisory
Certificate of On -Site Systems Approval #OSC 211241
Subdivision: Overlook Estates Block 2 Lot 5
Starting at 20 years of age the MOA issues Advisory's for steel septic tanks. The septic tank for
this property is 23 years old. Typical replacement costs range from $8,000 to $11,000
This advisory must be attached to all copies of the subject Certificate of On -Site Systems
Approval.
This is an example of what the metal of a 20 -year-old steel tank MAY look like.
� � ��; �� �� MailmgAddress PO�Box 196650'�anchorage;Alaska 99519 6650*www muni org �� " � r
�.�:. n.�.m,`�.�+..,,..-.:..x�s._>,�w,..:,,�,�x. �._,�� .�, ...%��..�'�w�✓r5� ,.,�}d.�, s,�'�.r.::;:M;M w' ��fi.?:s.a.+,�,:rM:: w.�. �.,r�?��i,...:,.�r,�a ,.,, :,?^,.�.��,� �� c...,...._ ,.,.�.�un v. ,r��ts,<
Municipality of Anchorage A.
Development Services Department _ <
K� -
Building Safety Division .5.E`r:
On -Site Water and Wastewater Program
4700 Elmore Street
P.O. Box 196650 Anchorage, AK 99519-6650
www. ci. anchorage. ak. us
(907)343-7904
Water Well Advisory
Certificate of On -Site Systems Approval (COSA) # OSC211241
During a recent COSA on-site inspection and test of the potable water
supply well on Block 2, Lot 5 of Overlook Estates subdivision, the well's
productivity was determined to be .58 gallons per minute. The minimum
well productivity required by this Department (AMC 15.55) for a 4 -bedroom
residence is .41 gallons per minute. Although the subject well currently
exceeds this minimum requirement, all parties concerned are advised that the
production capacity of the well may fluctuate. Restriction of non-critical
water uses such as washing cars and watering lawns and gardens may be
required.
This advisory must be attached to all copies of the subject Certificate of On -
Site Systems Approval.
4. STATEMENT OF INSPECTION BY ENGINEER
As certified by my seal affixed hereto and as of the validation date shown below, I verify that my investigation,
based on procedures outlined in the Certificate of On -Site Systems Approval Guidelines for this application,
shows that the on-site water supply and/or wastewater disposal system is (are) safe, functional and adequate
for the number of bedrooms and type of structure indicated herein. I further verify that based on the information
obtained from the Municipality of Anchorage files and from my investigation and inspection, the on-site water
supply and/or wastewater disposal system is(are) in compliance with all applicable Municipal and State codes,
ordinances, and regulations in effect at the time of installation.
Name of Firm Anderson Engineering
Address P.O. Box 240773 Anchorage, AK 99524
Engineer's Printed Name Michael E. Anderson, P.E.
Phone 522-7773
Date 3/5/2012
aZ k
s YAss•srsOF �
;�' 1. yi
t*/ 4g �\ p gym.
:44..4 et/ as.
441 ..MI01AEL E. NIDERSON. • .4
5. DSD SIGNATURE Approved for
�� CE -4381 .���``
si4
°�� P$g6fES`sit3�^`4:m
Disapproved.
Conditional approval for
bedrooms, with the following stipulations:
..• •_. .'iso:
WAT-RAD ' s;
WASTEWATER :
Attachments:
COSA Checklist X
Septic System Advisory
Well Flow Advisory
Nitrate Advisory
fA
(Rev 111057
Arsenic Advisory
Maintenance Agreements
Supplemental Engineer's Report
Other
��/f Original Certificate Date: 3 J F--/-2—
Municipality of Anchorage
Development Services Department
Building Safety Division
On -Site Water & Wastewater Program
4700 Bragaw Street
P.O. Box 196650
Anchorage, AK 99519-6650
www.muni.org/onsite
(907) 343-7904
CERTIFICATE OF ON-SITE SYSTEMS APPROVAL CHECKLIST
Legal Description: Lot 5, Block 2, Overlook Estates Subdivision
A. WELL DATA
Parcel ID: 068-041-11
Well type Private If A, B, or C provide PWSID # Well Log (Y/N) Y
Date completed 5/27/98 Sanitary seal (Y/N) Y Wires properly protected (Y/N) Y
Total depth 260 ft. Cased to 87 ft. Casing height (above ground) >18 in.
FROM WELL LOG AT INSPECTION
Date of test 5/24/98 3/4/2012
Static water level 240 ft. 226.4 ft.
Well production 1.0 g.p.m. 1.2 g.p.m.
WATER SAMPLE RESULTS:
Coliform 0 colonies/100 mL Nitrate .667 mg/L
Arsenic: N/D mg/I Date of sample: 2/21/12 Collected by: B. Schiller
B. SEPTIC/HOLDING TANK DATA
Tank Type/Material septic/steel Date installed 6/8/98
Tank size 1,250 gal. Number of Compartments Two Cleanouts (Y/N) Y
Foundation cleanout (Y/N) Y Depression over tank (Y/N) N High water alarm (Y/N) N
Date of pumping Pumper No Sludge in Tank
C. ABSORPTION FIELD DATA
Date installed 6/8/98 Soil rating (g.p.d./ft2 or ft2/bdrm)12 GPD/SF System type Deep Trench
Length 60 ft. Width 2.5
Total depth 9-10 ft. Eff. absorption area 632 ft2
ft.
Gravel below pipe 5.27
Monitoring tube Y Depression over field
N
Date of adequacy test 3/4/2012 Results (Pass/Fail) Pass For 4 bedrooms
Fluid depth in absorption field before test 0 in. Water added 600 gal. New depth 0 in.
Elapsed Time: 0 min. Final fluid depth 0 in. Absorption rate >= 600 g.p.d.
Any rejuvenation treatment (past 12 mo.) (Y/N & type) N If yes, give date
D. LIFT STATION
Date installed
"Pump on" level at in.
Datum
E. SEPARATION DISTANCES
Size in gallons
"Pump off' level at in.
Cycles tested
SEPARATION DISTANCES FROM WELL ON LOT TO
Septic tank/lift station on lot >100'
Absorption field on lot >100'
Public sewer main
Sewer /septic service line >25'
Animal containment areas >50'
N/A
Manhole/Access (Y/N)
High water alarm level at
Meets alarm & circuit requirements?
On adjacent lots >100'
On adjacent lots >100'
in.
Public sewer manhole/cleanout
N/A
Holding tank N/A
Manure/animal excrete storage areas >100
SEPARATION DISTANCES FROM SEPTIC/HOLDING TANK ON LOT TO:
Building foundation >5' Property line >5.
Absorption field >5'
Water main >10' Water service line >10' Surface water >100'
Wells on adjacent lots >100'
SEPARATION DISTANCE FROM ABSORPTION FIELD ON LOT TO:
Property line >10' Building foundation >10' Water main >to'
Water Service line >10' Surface water >100' Driveway, parking/vehicle storage >25'
Curtain drain None Noted Wells on adjacent lots >100'
F. COMMENTS:
G. ENGINEER'S CERTIFICATION
1 certify that I have determined through field inspections and
review of Municipal records that the above systems are in
conformance with MOA COSA guidelines in effect on this date.
Engineer's Printed Name Michael E. Anderson, P.E.
Date 3/5/2012
COSA Fee $
(Igo .0)
Date of Payment
Receipt Number
(Rev. 11/05)
3gollp.
623;3-6
Waiver Fee $
Date of Payment
Receipt Number
SGS
SCS Ref.#
Client Name
Project Name/#
Client Sample ID
Matrix
1120557001
Anderson Engineering
27509 Paramount Dr
27509 Paramount Dr
Drinking Water
Printed Date/Time
Collected Date/Time
Received Date/Time
Technical Director
02/29/2012 14:50
02/21/2012 13:45
02/21/2012 14:30
Stephen C. Ede
Sample Remarks:
Parameter
Results
LOQ
Units Method
Allowable Prep Analysis
Container ID Limits Date Date In it
Metals by ICP/MS
Arsenic
Waters Department
Total Nitrate/Nitrite-N
Microbiology Laboratory
E_ Coli
Total Coliform
ND
5.00
ug/L EP200.8
C (<101 02/21/12 02/23/12 NRB
02/27/12 CMA
A 02/21/12 DLC
A 02/21/12 DLC
0.667 0.100 mg/L SM20 4500NO3-F B (<[0)
Negative
Negative
1
1
100mL SM21 922313
100mL SM219223B
2 of 4
Municipality of Anchorage
Development Services Department
Building Safety Division
On -Site Water and Wastewater Program
4700 Elmore Road
P.O. Box 196650
Anchorage, AK 99507
www.muntorg/onsite
(907) 343-7904
CERTIFICATE OF ON-SITE SYSTEMS APPROVAL
FOR A SINGLE FAMILY DWELLING
Parcel l.D. 968441-11
COSA# 09033°I
Expiration Date: 3 0 - 0 cf
1. GENERAL INFORMATION
Complete legal description Lot 5, Block 2, Overlook Estates Subdivision
Location (site address) 27509 Paramount Drtve Eagle River, AK 99577
Current Property owner(s) Thomas Vickrey Day phone 6964354
Mailing address 27509 Paramount Drive Eagle River, AIC 99577
Lending agency Day phone
Mailing address
Real Estate Agent Day phone
r
Mailing Address N
Unless otherwise requested, COSA will be held by DSD for pickup.
2. NUMBER OF BEDROOMS:
Four(4)
I
3. TYPE OF WATER SUPPLY: TYPE OF WASTEWATER DISPOSAL:
Individual Well I] Individual On-site ❑
Individual Water Storage 0 Individual Holding Tank 0
Community Class Well 0 Community On-site 0
Public Water System 0 Public Sewer 0
The Municipality of Anchorage Development Services Department (DSD) Issues Certificates of On -Site Systems
Approval (COSA) based only upon the representations given In paragraph 4 by an independent professional civil
engineer registered in the State of Alaska. Certificates of On -Site Systems Approval are required for the transfer of
title (except between spouses) for properties served by a single-family on-site wastewater disposal and/or water
supply system. DSD also issues COSAs upon request to homeowners. Certificates of On -Site Systems Approval
are valid for 90 days from the date of issue for properties served by a private or Class C well and may be reissued
with new water sample results. (Certificates may be reissued for a period of up to one year with valid water
samples.) Certificates are valid for one year for properties served by Class A or B wells or a public water system.
The Municipality of Anchorage is not responsible for errors or omissions In the professional engineer's work.
4. STATEMENT OF INSPECTION BY ENGINEER
As certified by my seal affixed hereto and as of the validation date shown below, I verify that my investigation,
based on procedures outlined in the Certificate of On -Site Systems Approval Guidelines for this application,
shows that the-on=site water supply and/or wastewater disposal system is (are) safe; functional and adequate
for the number of bedrooms and type of structure indicated herein. I further verify that based on the information
obtained from the Municipality of Anchorage files and from my investigation and inspection, the on-site water
supply and/or wastewater disposal system is(are) in compliance with all applicable Municipal and State codes,
ordinances, and regulations In effect at the time of installation.
Name of Firm Anderson Engineering
Address P.O. Box 240773 Anchorage. AK 99524
Engineer's Printed Name Michael E. Anderson. P.E.
Phone 522-7773
Date 9009
irtvc
:.. •.... •-: .. f..,
•.° t MICHAEL 5. ANDERSON le
5. DSD SIGNATURE I "J :• CE -4381 :-.4:-
�
(/ Approved for if bedrooms. 1 9es ........• ,.,
Disapproved. ,, "\
Rh xt.st - c
Conditional approval for bedrooms, with the following stipulations:
��: ON CITE •'i.
%•::Z: WATER AND ; m
WASIEWAItK
• PROGRAM
tom.
•.
•
Attachments:
COSA Checklist X Arsenic Advisory .
Septic System Advisory Maintenance Agreements
Well Flow Advisory Supplemental Engineer's Report
Nitrate Advisory Other
By: 1(/ TSCfraOriginal Certificate Date: 7---g n-0 I
(Rev.11/05)
Municipality of Anchorage
Development Services Department
Building Safety Division
On -Site Water & Wastewater Program
4700 Bragaw Street
P.O. Box 196650
Anchorage, AK 99519-6650
www.muni.org/onsite
(907) 343-7904
CERTIFICATE OF ON-SITE SYSTEMS APPROVAL CHECKLIST
Legal Description: Lot 5, Block 2, Overlook Estates Subdivision
A. WELL DATA
Well type Private
Date completed 5/27/98
Total depth 260 ft.
Date of test
If A, B, or C provide P WS ID #
Sanitary seal (Y/N)
Cased to B7 ft.
FROM WELL LOG
5/24/98
Static water level 240 ft.
Well production 1.0
WATER SAMPLE RESULTS:
g.p.m.
Coliform 0 colonies/100 mL Nitrate 284 mg/L
Arsenic: NM mg/1 Date of sample: 8/30/09
B. SEPTIC/HOLDING TANK DATA
Tank Type/Material septic/steel
Tank size 1.250 gal. Number of Compartments Two
Parcel ID: 068-041-11
Well Log (YIN) Y
Wires properly protected (YIN) v
Casing height (above ground) >18 in.
AT INSPECTION
6/26/09
117.4 ft.
1.4 g.p.m.
Other bacteria 0 colonies/100 mL
Collected by: S. Gilbert
Date installed 6/8/98
Cleanouts (Y/N)
Foundation cleanout (Y/N) V Depression over tank (Y/N) N High water alarm (Y/N)
Date of pumping 6/14/09
Pumper JR's Pumping
C. ABSORPTION FIELD DATA
Date Installed 6/8/98 Soil rating (g.p.d./ft' or ft=Ibdrm) t.2 GPD/SF System type Deep Trench
Length 60 ft. Width 2.5 ft. I Gravel below pipe 5.27 ft
Total depth 9-t0 ft. Eff. absorption area632ft2 Monitoring tube Y Depression over field N
Date of adequacy test 6/14109 Results (Pass/Fail) Pass For 4 bedrooms
Fluid depth in absorption field before test -0 in. Water added 600 gal. New depth 1
Elapsed Time: 6 min.. Final fluid depth 0 in. Absorption rate >= 600
•
Any rejuvenation treatment (past 12 mo.) (Y/N & type) -N
If yes, give date
g.p.d.
D. UFT STATION
Date installed
Size in gallons
"Pump off' level at
Manhole/Access (Y/N)
High water alarrn level at
'Pump on level at _ in. in in.
Datum Cycles tested Meets alarm & circuit requirements?
E. SEPARATION DISTANCES
SEPARATION DISTANCES FROM WELL ON LOT TO:
Septic tank/lift station on lot >100' On adjacent Tots >too'
Absorption field on lot >100' On adjacent lots >100'
Public sewer main N/A Public sewer manhole/cleanout N/A
Sewer/septic service line >25' Holding tank N/A
Animal containment areas None Manure/animal excrete storage areas None
SEPARATION DISTANCES FROM SEPTIC/HOLDING TANK ON LOT TO:
Building foundation >5'
Water main >10'
Wells on adjacent Tots >100'
SEPARATION DISTANCE FROM ABSORPTION FIELD ON LOT TO:
Property line>5_ Absorption field >5'
Water service line >70' Surface water >100'
Property line >10' Building foundation >10'
Water Service line >t0'
Surface water >100'
Water main >10'
Driveway, parkingNehicle storage >25'
Curtain drain None Noted Wells on adjacent lots >too'
F. COMMENTS:
G. ENGINEER'S CERTIFICATION
I certify that I have determined through field inspections and
review of Municipal records that the above systems are in
conformance with MOA COSA guidelines In effect on this date.
Engineer's Printed Name Michael E. Anderson, P.E.
Date 9/29/2009
s OF A(+�
ate, 00000000
t -f-
As
4911:1 t*Ii
• ¶ MrCNAEtE Tir/DERSON
mss: 'CE=4asi :•.r`�L
•141:- (Esso, -.0 '
COSA Fee $ tiq 0
Date of Payment
Receipt Number
(Rev. 11/05)
7Ufoq
"1179 S
Waiver Fee $
Date of Payment
Receipt Number
1
UNSUBDIVIDED
11 esMe17'w 1
Lot 4
8
$ 84.405..E 135.a
•
PARmioutf DR -NE
Lot 6
10' TELECOM. e
LLECT. EASEMENT
PLOT PLAN _ ASBUILT _E. SCALE I. • CO' GRID "465 Pro/foot No r -12o
Lang & Associates, inc. 11500 Daryl Avenue, Anchorage, Aiaeka 99515
Registered Land Surveyors (907) 522-4625 Fax
1 Mraty toffy OS 1 haw -v..yd er lotalne dwertLd property:
Lot 5Nook 2. owEmAOK EZTAIQ (Nd lid 114-2S7)
Mannar Ibrendlne ork$M.. Ss. aS tot Ku b novo nMl..Mud.d
1h.r-on en .Mkr IM prapoy it ad d. M noel. onto 1M pd tl.ay
adpTee.ori re. n.at no Improvements -n . proper Nino o,wr
oo
o aroosh on IM anq-d dreads ad ent fent on no teeAnr.. Irprwri.l.n
Ira or odor Nod, -o.r.ndo on odd property aos.pt es k+Ml-d hon -of.
pond . the Day edDay of MI ?sal. el Meheraa.. Mads
if is 11to orl.1 or ...M.h.no rrld.h dodos not es N
any
sownonto.
plot
-n the r-ordd
o
SGS Ref.#
Client Name
Project Name/"
Client Sample ID
Matrix
1094544001
Anderson Engineering
Lot 5,Block 2 Overlook
Lot 5,Block 2 Overlook
Drinking Water
Printed Date/time
Collected Date/time
Received Date/Time
Technical Director
09/17/2009 15:53
08/30/2009 9:30
08/31/2009 8:55
Stephen C. Ede
Sample Remarks:
Parameter
Results
POL
Units Method
Allowable Prep Analysis
Container ID Limits Date Date Inn
Metals by ICP/M3
I lardness as CaCO3
Waters Department
Total Nitrate/Nitrite N
Private Individual Analysis
Aluminum
Antimony
Arsenic
Barium
Cadmium
Calcium
Chromium
Copper
Iron
Lead
Magnesium
Manganese
Chloride
Fluoride
Selenium
Sodium
Silver
Sulfate
Thallium
Zinc
152 5.00 mg/L SM20 23408 C
0.284 0.100 mg/L SM20 4500NO3-F 13
09/08:09 09/10/09 NRB
09/01/09 KIT
ND 20.0 ug/L EP200.8 C 09/08109 09/10/09 NRB
ND 1.00 ug/L EP200.8 C (<6) 09/08/09 09/10/09 NRB
ND 5.00 ug/L EP200.8 C (<10) 09/08/09 09/10/09 NRB
22.2 3.00 ug/L EP200.8 C (<2000) 09/08/09 09/10/09 NRB
ND 0.500 ug/L EP200.8 C (<5) 09/08/09 09/10/09 NRB
40400 500 ug/L EP200.8 C 09/08/09 09/10/09 NRB
ND 2.00 ug/L EP200.8 C (<100) 09/08/09 09/10/09 NRB
50.4 1.00 ug/L EP200.8 C (<1300) 09/08/09 09/10/09 NRB
ND 250 ug/L EP200.8 C (<300) 09/08/09 09/10/09 NRB
0.260 0.200 ug/L EP200.8 C (<15) 09/08'09 09/10/09 NRB
12400 50.0 ug/L EP200.8 C 09/08109 09/10/09 NRB
4.19 1.00 ug/L EP200.8 C (<50) 09/08/09 09/10/09 NRB
1.09 0.100 mg/L EPA 300.0 D (<250) 09/08'09 09/09/09 LCE
0.210 0.100 mg/L EPA 300.0 D (<2) 09/08/09 09/09/09 LCE
ND 5.00 ug/L EP200.8 C (<50) 09/08/09 09/10/09 NRB
540 500 ug/L EP200.8 C (<250000) 09/08/09 09/10/09 NRB
ND 1.00 ug/L EP200.8 C (<100) 09/08/09 09/10/09 NRB
62.3 0.200 mg/L EPA 300.0 D (<250) 09/08/09 09/09/09 LCE
ND 1.00 ug/L EP200.8 C (<2) 09/14/09 09/16/09 NRB
9.38 5.00 ug/L EP200.8 C (<5000) 09/08/09 09/10/09 NRB
SGS Rag
Client Name
Project lame/p
Client Sample ID
Matrix
1094544001
Anderson Engineering
Lot 5,Block 2 Overlook
Lot 5,Block 2 Overlook
Drinking Water
Printed Date,Time
Collected Date/Time
Received Date/Time
Technical Director
09/17/2009 15:53
08/30/2009 9:30
08/31/2009 8:55
Stephen C. Ede
Parameter
Results
PQL
Units Method
Allowable Prep Analysis
Container ID Limits Date Date Init
Private Individual Analysis
Total Dissolved Solids
Nickel
11CO3 Alkalinity
CO3 Alkalinity
011 Alkalinity
Conductivity
pil
Alkalinity
334
2.53
202
ND
ND
599
7.40
202
10.0
2.00
10.0
10.0
10.0
1.00
0.100
10.0
mg/L
ug/L
mgr/.,
mg/L
mg/L
umhos/cm
pll units
mg/L
SM20 2540C
EP200.8
SM20 23208
SM20 23208
SM20 23208
SM20 25108
SM20 4500.1113
SM20 2320B
D (<500) 08/31/09 OLT
C (<100) 09/08/09 09/10/09 NRB
D 09/10/09 MPL
D 09/10/09 MPL
D 09/10/09 MPL
D 08/31/09 OLT
D (6.5-8.5) 08/31/09 OLT
D 09/10/09 s
Colony Count
Total Coliform
Fecal Coliform
179
Positive
Negative
co1/100mL SM20 922213
co1/100mL SM20 92226
col/100mL SM2092228
SCE TLS -re. s -r
7118109
A
A (<1)
A
08/31/09 DLC
08/31/09 DLC
08/31/09 DLC
SGS RetN
Client Name
Project Name/a
Client Sample ID
Matrix
1095061001
Anderson Engineering
L5,82 Overlook Est
Hose Dib
Drinking Water
Printed Date/Time
Collected Date/Time
Received Datelfime
Technical Director
09/23/2009 10:25
09/18/2009 9:20
09/18/2009 10:05
Stephen C. Ede
Sample Remarks:
Parameter
Results
PQL
Units Method
Allowable Prep Analysis
Container ID Limits Date Date Mit
Microbiology Laboratory
Colony Count
Total Coliform
Fecal Coliform
0
0
0
co1/I00mL SM20 92228
col/100mL SM20 92228
col/I00mL SM20 922213
A
A
A
(<200)
(<1)
(<1)
09/18/09 DLC
09/18109 DLC
09/18/09 DLC