No preview available
HomeMy WebLinkAboutLAKE O THE HILLS BLK 3 LT 4Lake 0 th Hills Block 3 Lot 4 #015-331-25 MUNICIPALITY OF ANCHORAGE Development Services Department Phone: 907-343-7904 On-Site Water & Wastewater Section Fax: 907-343-7997 Pump Installation Log Well Drilling Permit Number: _______________ Date of Issue: ____-____-____ Parcel Identification Number: ____-____-____ Legal Description Block Lot Property Owner Name & Address: Pump Installation Date: _____-_____-_____ Pump Intake Depth Below Top of Well Casing: __________ feet Pump Manufacturer’s Name: ___________________________ Pump Model: _____________________________________ Pump Size: ____________hp Pitless Adapter Burial Depth: _________ feet Pitless Adapter Manufacturer’s Name: _________________________ Pitless Adapter Installer: ____________________________ Well Disinfected Upon Completion? XX Yes No Method of Disinfection: _____________________________ Comments: Pump Installer Name: __________________________________ Company: ___________________________________________ Mailing Address: ______________________________________ City: ___________________ State: __________Zip: _________ Attention: The pump installer shall provide a pump installation log to On-site within 30 days of pump installation. Development Services Department :'~ [-~: Building Safety Division On-Site Water and Wastewater Program. 4700 S. Bragaw St. P.O. Box 196650 Anchorage. AK 96519-6650 Page of www.ci, anchorage.ak.us (907) 343-7904 ON-SITE WASTEWATER DISPOSAL SYSTEM AND/OR WELL INSPECTION REPORT tltt~.~ F{~,]~[td. LAI~-._ ~r-:~-~t ABSORPTION FIELD LEGAL DESCRIPTION Well: [] New [] Upgrade ~ F,. {~'I J ~ 't' n. TANK SEPARATION DISTANCES ~[septic [] Holding [] S.T.E.P. [] Other. ~ Septic Absorptior Lift Holding Publ~,/Pfi~at~ l~an~c~ ~.~w.,, "lo t'il° V LIFT STATION ~' BENCH MARK Engineees Stamp Inspections pedormed by: ~ ~ Dates: 1"~/~lt Approval Reviewed and approved by: Date: TOTAL Lkc'PIH I0 IT TOTAL I. ZT~,r# 80 ri' ETrL'c ~eOCK $ 17 A6 ~4.0 AR 133 I250 6AL ~ TANK SY/~17~ AC l&O IT BC 28.0 AD 30.0 BE 255 A~ 84.0 B~ 48.5 Al:' 12.2 i~ 49~h II I[OeBEN SPURKLANO P.E. 205 W 15Ttl. AVENUE ANCH. AK. ~9501 (907) 279-3916 PE£HIT # SVflflf1476 ! ! I ~reIl / "LAKE O'THE HI: LOT 4 BLOCK 3 SIEGFRIED TESS~tER 1oo PI:~ # 015-331w25 1.5o /// / / / / / / ! ! I SEPTIC SYSTEM AS BUILT DATE: SEPT. 11, 2001 SHEET: 2/$ GRID: 26:79 L TlqOSO4£.Bh/6 .,~ 00~0 0 0 Xtandard Trenche~ ~' Vide 48' Long 10' ~eep Monlgor Oeanouts 3' Cover SII~ B~rrler 7.8 ~ o~ Septic Rock ~ NO SCALE ~03 VlS~h 6ye LOT ~ BLOCK J ~at[, 5EPT. I1, ~081 Anchorage Ak 99501 ~ T.SPURKLAND P.E. 203 WEST I STI I. AVENUE SUITE 203 ANCI lOP, AGE, ALASKA 99501 ~',.u 7127't-3'i i0 Fax (907)276-6OI3 January l6,2002 Municipality of Anchorage Development Services Department Buildine Safety Division On-Site Water and Wastewater Program P.O. Box 196650 Anchorage AK. 995169-6650 Subject: "Pink Sheet" Lake O'The llills, Block 3 Lot 4 The discrepancy between the shown location of the test hole on permit drawing and the As Built is caused by inaccurate location on the permit. He location of the permit drawing was "eyeballed" while the as built location was established with swing ties. The tree location ofthe test hole is approximately 25 feet distant from the location shown on the permit drawing. The one trench was also rotated to save existing trees. Yours truly, Tobben Spurk!and P.E. MUNICIPALITY OF ANCHORAGE Department of Health and Human Services On-Site Services Program 825 L Street, Room 502 P.O. Box 196650, Anchorage, AK 99519-6650 (907) 343-4744 5': ON-SITE WASTEWATER DISPOSAL SYSTEM PERMIT Upgrade Date Issued: Nov 13. 2000 Expiration Date: Nov 13.2001 Permit Number: SW000476 Legal Description: LAKE O THE HILLS BLK 3 LT 4 Design Engineer: 0007 Tobben Spurkland, PE Owner Name: Siegfried Tessmer Owner Address: 11400 Mountain Lake Dr, Anchorage, AK 99516- Parcel ID: 015-331-25 Site Address: 011400 MOUNTAIN LAKE DR Lot Size: 74938 SQ. FT. Total Bedrooms:,~3' Permit Bedrooms: This permit is for the construction of: [] Disposal Field [] SepticTank [] Holding Tank [] Privy [] Private Well [] Water Storage All construction must be in accordance with:" 1. The attached approved design. 2. Ail requirements specified in Anchorage Municipal Code Chapters 15.55 and 15.65 and the State of Alaska Wastewater Disposal Regulations ( 18AAC72 ) and Drinking Water Regulations ( 18AAC80 ). 3. The engineer must notify DHHS at least 2 hours prior to each inspection. Provide notification by calling (907) 343-4744 ( 24 hours ). ( Not required for a Water Supply Permit only ). 4. From October 15 to April 15, a subsurface soil absorption system under construction during freezing weather must be either: A. Open and closed on the same day. B. Covered, sealed, and heated to prevent freezing. Received By: Issued By: Date: //' 203 W 15th. Avenue, Suite 203 ANCHORAGE, ALASKA 99501 (907) 279-3916 Fax (907)-276-6013 SEPTIC SYSTEM DESIGN LOT 4 BLOCK 3 LAKE O'THE HILLS SIEGFRIED TESSMER Municipality of Anchorage Deparlment of Health and Social Services 8201 Street Anchorage, Alaska 99501 November 13, 2000 We are submitting an application for the upgrade of the septic system for this lot. The submittal consists of three (3) drawings showing the present improvements on the lot and the adjoining properties, (sheet 1/3), the proposed improvements of the lot, of which only the septic system is subject to this permit application, (sheet 2/3), and a schematic of the septic system, (sheet 3/3). Soil logs and percolation tests of applicable testholes are also enclosed. The septic system design is based on the following: No Ground Water or Impervious Layer to 16 fl. Use Standard Trench Soil Rating. From Testhole 10/19/00 27 rain/in -- 0.6 gal per sq.f'dday No. of Bedrooms 4 Required Area per Bedroom: 15010.6 ~250 sq.ft. Total area required: 250 x 4-- 1000 sqft Testhole depth 16 feet Bottom Rock At 10 feet Top Rock At 3 feet Rock Depth 7 feet Total Trench Length 1000 / 14 = 71.5 ft. Use two trenches each 40 feet long SYSTEM CONFIGURATION STANDARD TRENCII TOTAL LENGTH 80 FT TOTAL WIDTtl 2 FT TOTAL DEPTil 10 FT ROCK DEPTH 7 FT COVER 3 leT SEPTIC TANK 1250 GAL CllECK INTEGRITY OF EXIST. TANK The installation of this septic system will not prevent wells from being installed on the adjacent lots. There are no developed or natural surface / sub surface drainage courses on this or the adjacent lots. The proposed septic system will not change the general slope of the area. Ponding and/or concentration of surface runoffwill not result from this installation. SPLB'TE£ 12§0 GAl. EXIST. SUNSET PLASTIC CHECK INTEGRITY TOBBEN SPURKLANO P.E. 205 I¢ ISTH. AVENUE PE£MU # SVOOOXXX II '~ Il'ell ! ! / LAKE O"IlIA' IIILLS LOT 4 BLOCK $ SIEGFRIED TESSMER I PID # 015-331-£5 / / // I I I I I I / SEPt'lC SYSTEId DESIGN DATE: OCT 26, 2000 SHEET: 2/3 GRID: 2859 L THO3042.DV6 FLOW SPLITTER 7'0 £XISTING I250 gol Sept;c Stond~rd frenche$~ ,2' Vide 40' Long 10' Beep ZO' Sewer rock $' Cover NO SCALE Silt Borrier 7.0 f't of' Septic Rock Effective / Monitor ~- Cleanouts / /~ 3' Cover NO SCALE . ~......~ ........... ~ ......... ..¢...,, ~ ,."~, .. NO. CE-~BB~5 ... ~ ........ 1250 gal. septic tonk EX/STING SPURKLAND PY, P03 ~/15th Ave Anchor'oge Ak 99501 L4KE O'TtlE tlILLS LOT 4 BLOCK J SlEGF£1ED TESs~IER SEPTIC SYSTEM SCHEMATIC DATE, OC~ 26, 2000 SHEET, GRID: ~639 # SWOOOOXX PARCEL ID /I 015-3,51-25 LI'tlO,504,5. DWG 203 W 15th. Avenue. Suite 203 ANCIlORAGE, ALASKA 99501 (907) 2?9°3916 Fax (907)-276-6013 SEPTIC SYSTEM DESIGN LOT 4 BLOCK 3 LAKE O'THE HILLS SIEGFRIED TESSMER Municipality of Anchorage Department of Health and Social Services 8201 Street Anchorage, Alaska 99501 October 26, 2000 We are submitting an application for the upgrade ofthe septic system for this lot. The submittal consists of three (3) drawings showing the present improvements on the lot and the adjoining properties, (sheet 1/3), the proposed improvements of the lot, of which only the septic system is subject to this permit application, (sheet 2/3), and a schematic of the septic system, (sheet 3/3). Soil logs and pemolation tests of applicable testholes are also enclosed. The septic system design is based on the following: No Ground Water or Impervious Layer to 16 ft. Use Standard Trench Soil Rating. From Testhole 10/19/00 27 mln/in=0.6 gal persq.ft/day No. of Bedrooms 3 Required Area per Bedroom: 150/0.6 -- 250 sq.fl. Total area required: 250 x 3 = 750 sqft Testhole depth 16 feet Bottom Rock At 10 feet Top Rock At 4 feet Rock Depth 6 feet Total Trench Length 750 / 12 = 62.5 ft. SYSTEM CONFIGURATION STANDARD TRENCII TOTAL LENGTH 62.5 FT TOTAL WIDTtl 2 FT TOTAL DEPTII 10 FT ROCK DEPTH 6 let COVER 4 FT SEPTIC TANK 1000 GAL CllECK INTEGRITY OF EXIST. TANK The installation of this septic system will not prevent wells from being installed on the adjacent lots. There are no developed or natural surface / sub surface drainage courses on this or the adjacent lots. The proposed septic system will not change the general slope of the area. Ponding and/or concentration of surface runoffwill not result from this installation. PERFORMED FOR: Munlcll:allty of Anchorage DEPARTMENT OF .~EALTH & HUMAN SERVICES 825 'L" Street. Almhorage, Alaska 99502-0650 SOILS LOG - PERCOLATION TEST · , .,: (ENGINEER'SSEAL) I ' : T,;:, -.'. , ;_-~J · '" ~t',,'""'"." DATE PERFORMED: jo/ lq lO O LEGAL DESCRIPTION: L~'i'~(1 ~V- ~) Township. Range. Section: 1 2 3 4 5 6 7 8 9 10- 11- 12- 13 14 15 16 17. 18- 19- 20- SLOPE SITE PLAN WASCROUNDWATER ENCOUNTERED? S IF YES, AT WHAT DEPTH? p E Olp~htoWallrAl~ . . filofliloring? ~ OaTe: Gross Net Depth to Net Feeding Date Time Time Water Drop N:i~ '~o ~ 0 '/'t 1~.o q.: ~-~ ~,0 1~'7,~, I '1~, PERCOLATION RATE ,~ '''/ (mmules~mch) PERC HOLE DIAMETER TEST RUN BETWEEN ~ FT AND ~ FT DISCLAIHFR~ ~rnundwatoe cnndftinns indicated atp fnr the dates shown only. Past and future presence and/or depth of groundwater can not be predicted trom these observations, / / 3 // / / // // / \ 4 49th ~ ~N :~ pUR'K/AN [I NO. CE-~2E'5 RECKRIDGE 6 5 DRIVE 0 ! ' ~0 100 i~q~ I~ = I00 FT. 7 JI'OBBEN SPURKLAND P.E. 205 W ISTH. AVENUE ANCH. AK. 99501 PERmT # ~WOOOXXX II LAAZ' O"JtlE t/ILLS LOT 4 BLOCK $ SIEGFRIED TESSMER P1D # 015-$31-a~5 SEPTIC SYSTEkl DESIGN DATE: OCT 26, 2000 SHEET: I/$ GRID: 2659 L THO3041.Db'G - / ~ ~ ~. ~ / TOTAL LENgr~ ~2.5 F ~5 O ~ ~ [F~C. R~K ~ Fr ¢OVER 4 ~ EXIST. SUN$£T £C4STIC I~O~BE~ SPURK~ND P.E. 203 VZ 15TH. AVENUE ANCH. AK. 99501 (goz~ 279-3916 PERMIT # SWOOOXXX N LOT 4 BLOCK 3 SIEGFRIED TESS~IER PID # 015-331-£5 // I / I / I I SEPTIC SYSTEI~ DESIGN DATE: OCT 26, 2000 SHEET: 2/3 GRID: 2639 L THO304£.D WG Standard Trench: 2' ~/ide 82.5' L on9 10' £eep 6.0' Sewer rock 4' Cover NO SCALE Monitor Si(t £orr;er 6.0 £t of Septic Rock Effective I000 gal Septic tank £XISI'IN~ ~ Oeanouts / /-- 4'Cover NO SCALE : H 1000 gal. septic tank £XISTIN~ IU~BEN SPUNKLAND P.E, ~03 ~lSth Ave Ancho¢oge AA 99501 LAKE O'TflE tlILLS LOT 4 BLOCK 3 $1E~F£1ED TE$SWE£ SEPTIC SYSTEM SCHEMATIC DATE: OC~, 2~, 2000 SHEET, GRID: £~39 PERI/IT # SWOOOOXX PARCEL ID I~ 015-331-25 LH~O$O43. DWG Hea~ and Environmental Protec . L_~,.Fourth Floor West ~ 825 L Street *' Anchorage, Alaska 99501 279-2511, x 224, 225 INSPECTION REPORT ON-SITE SEWAGE DISPOSAL SYSTEM NAME ~'~lJ F~.~'L_.Y)t~L~._ MAILING ADDRESS ...... PHONE ~'_~.~~.. SEPTIC TANK: DISTANCE 'J 0C.') ~' .'r ..... ~ J)j0.,o~¢--'> _ .~'L.__(~?'_ __~_~ NUMBER OF FROM WELL. MANUFACTURER ___~- ~- MATERIAL -- % COMPARTMEN~'S INSIDE LENGTH ............ INSIDE WIDTH ........ LIQUII) E)EP[H ....... lIQUID CAPACITY TILE DRAIN FIELD: ''~ ¢ t , TOTAL LENGTH D~STANCE r:ROM WELL .... (00 ~ FOUNDATION_ ~0 '~ NEAREST LOT LINE: ................ ~O '~ OFI N~,_ ¢ 9 of Lines ..... ~.__ DISTANCE BETWEEN LINES _-- ~--. -rRCNCH WJDTH%~ IN. TOJ-AL EFFECTP/F_ ABSORPTION AREA .... ~_~ SQ. Fl-. LENGTH OF EACH LINE ._2~_~7__~. ~C ~. L9 ,A DEPT~I OF FILTER DEPTIi: TOP OF TILE TO FINISII GRADE ......... ~ MATERIAL BENEATH TILE ......... ~ IN. ABOVE TILE '~ IN. SEEPAGE PIT: Log Crib Rings BUILDING FOUNDATION__ DIAMETER -- OR WIDTH .. , ILENGTH__, DEP1-H Crib Size: DIAMETER ..... DEPrH .... DISTANCE FROM: WELL TOTAL EFFECTIVE NEAREST LOT LINE ..... ABSORPTION AREA (WALl_ AREA) _ ~ ,SQ. F'I. Well ClassL , O. De h: Well Distance To: Lot Line iO~ Bldg: ~O~-~ S?wer rLine: Pipe Materials. # of Bedrooms: Installer: Remarks: ~ERMIT NO. APPLICANT SIEGFRIED TESSMER LOCATION MT.~L. AKE DR LEGAL L4 8~LAKE 0 THE HILLS SD [:,EPF~F.:TMENT HEALTH AN[:, ENVIRONMENTAL. ,=,~._ "L" STREET., ANCHORAGE., AK. DD~,¢):L 27'~-25'.1..~.. ~-~ E L L A ~4 E:, CI ~4 -- S Z T E ~1 E ~4 E ~: ..... _..., TEF.:RY PLACE :OTEE:T I ON ~ ~' ' PEP-.,---, :,: '-r A.,EEbp/XL LOT '_-SIZE ,.'4~.:~L. ld 'SQUARE EEET TYF'E OF SOIL RBSERETION _.,T=TEM IS: [)RRINFIELD E,E[.F..U_I~= = 4 =,JIL RATING ,:;SD FT,-."BR)= ±~..- MAX I MIJM NIJMBER OF ', ' - n ', "- THE REQUIRE[:, SIZE OF THE SOIL RE,=,~FTION SYSTEM IS: [)EF']-H= THE LENGTH DIMENSION IS THE I_ENGTH (IN FEET) OF THE TRENCH OR DRAINFIELD. THE DEPTH OF A TRENCH OR PIT IS THE DISTANCE BETWEEN THE SURFACE OF ]'HE GROUND AND ]'HE BOTTOM OF THE EXCRMATION (IN FEET). THE TRENCH WIDTH FOR DRAINFIELDS IS 2: FEET. THE GRAMEL DEPTH IS THE MINIMUM DEPTH OF GRRYEL BETWEEN THE OUTFALL PIPE AN[.', THE BOTTOM OF THE E>:',CAMATION (IN FEET). F"AC:~-::A~3E F'LAI-~]- CIF'T I C~-~ R PACKAGE PLANT MAY BE INSTALLED AT THE PERMITTEE'"S OPTION SUBJECT TO THE FOLLOWING CONDITIONS: '1. EITHER A CLASS I OR II NSF APPROMED PLANT MAY BE INSTALL. ED. 2. A CONTINUOUS MAINTENANCE AGREEMENT IS REQUIRED. IF A MAINTENANCE AGREEMENT IS NOT KEPT CURRENT YOU MAY BE REQUIRED TO ENLARGE THE SOIL ABSORPTION SYSTEM AND/OR YOU MAY BE SUBJECT TO PROSECIJTION. BACKFILLING OF ANY SYSTEM WITHOUT FINAL INSPECTION AND APPROVAL BY THIS DEPARTMENT WILL BE SUBJECT TO PROSECUTION. MINIMUM DISTANCE BETWEEN R WELL AND ANY ON-SITE SEWAGE DISPOSAL SYSTEM IS ±00 FEET FOR A PRIMATE WELL OR 200 FEET FOR R PUBLIC WELL.. WELL LOGS ARE REQUIRED AND MUST BE RETURNED TO THE DEPARTMENT WITHIN ]:E~ DAYS OF THE WELL COMPLETION. OTHER REQUIREMENTS MAY APPLY. SPECIFICATIONS AND CONSTRUCTION DIAGRAMS ARE AVAILABLE TO INSURE PROPER INSTALLATION. F'EF~-':I'-I I T E:~-(F" I F.'.ES [:.EC:EI"IBER S:::.t... :]L.:Bi---'? I CERTIF"r' THAT =,EWEF..=. AN[:' WELL'=] FrZ, '~' .... · 1: I AM FRMILIRR WITH THE F.!EQUIREMENTS FOR ON-SITE '- "- =.El FOF.:TH BY THE MI_INICIPRLITY OF HNL. HUF. H_~E. 2: I WILL INSTFtLL THE: ~-r_,TEM IN ACCORDANCE WITH THE CO[:,ES ~:: I UN[.EE=,TMN[. THAT THE ON-SITE _,EWEF.. SYSTEM MAY REQUIRE ENLHF..~EIIENT IF THE RESIDENCE ,,IS REMODELED TOAINC:LUDE MCgeE THAN 4 BE[:,ROOMS. ................ ........................... ,,., PERFORMED FOR: LEGAL DESCRIPTION: MUNICIPALITY OF ANCHORAGE DEPARTMENT OF HEALTH AND ENVIRONMENTAL PROTECTION Pouch 6-650, Anchorage, Alaska 99502 276-2221' SOILS LOG- PERCOLATION TEST [] SOILS LOG PERCOLATION TEST ?- ?o-7¢ 6 7 8 9 10 11 13 14 15 16 17 18 19 2O COMMENTS ;LOPE WAS GROUND WATER ENCOUNTERED? IF YES, AT WHAT DEPTH7 SITE PLAN Gross Net Depth to Net Reading Date Time Time Water Drop ~. ~ ' r z : o ..( ,4 ~ iff I, ~ PERCOLATION RATE / ''/ /q 0 e ~ (minutes/inch) TEST RUN BETWEEN '7 FT AND ?' ''~ FT PERFORMED BY: G~'/'I,--Y ._T ~ E~'/~'~77 DATE: 72-008 (7/76) · TESTING · EXPLORATION · CHEMICAL · MATERIALS · INSPECTION 279-258[ {940 pOST ROAD ANCHORAGE, ALASKA 9950{ Dickinson-Oswald-Welch-Lee, Engineers 800 Cordova Street Anchorage, Alaska 99501 June 19, 1974 W.O. 16757 Attn: Mr. Lewis Dickinson · Subject: Seepage Pi/Analysis Lot 4A, Blk 3, Lake O' The Hills Subd. Gentlemen: Transmitted herein are -the results of the subsur£ace investigation performed on the above property. Exploration consisted of one 121 testhole drilled by Denali Drilling Inc. employing Nodwell mounted, mobile B-50 drill, fitted with an 8" hollow stem, continuous flight auger. A grab sample was taken at 2.5I, by puLling the auger out of the test hole and removing the sample from the flights of the auger from near the bit. Standard penetration samples were taken at 5.0 - 6.5 and 10.0 - 11.5. These samples were taken with 2" O.D, split spoon sampler advanced into the soil by the action of an 1407ound hammer free £alling 30". The blows required to dr£ve the-s~mpler 12" is, by definition, the standard penetration. The softs were visually classified in the field in accordance with sheets i through 3, following the text. This £ield classification was verified by visual review of s~mples ba'sed on the s~me criteria, in the laboratory. The drilling was supervised and the test hole was logged by T.N. Huber, geologist of our staff. The test hole was logged as follows: Depth in Feet - FROM TO SOIL ' DE S CR!PTION 0 1.5 1.5 5.0 5.~0 5.5 5.5 12.0 NFS/F-l, Grey-Brown Silty Sandy Gravel with organic debris (duff, branches, etc.) and man~ Cobbles F-l, Tan Silty Sandy Gravel with occasional Cobbles and Boulders, Damp, Medium Density, GM F-4, Brown Clayey Silt, Damp, Stiff, PI+, Lw-, ' ML-CL '~ NFS, Grey Brown Sandy Gravel with many Cobbles ~nd Boulders and Random Silt Layers, :Damp, Medium Density, GP MEMBER DickinSon Oswald ¥;,~a '~ Lee Page 2 Tune 19, 1974 Bottom of Test Hole: 12 ft. Frost Line: 4!-+ Free Water Level: None Observed Sample :Depth 1 2.5 2 5 -6.5 Type of Sample Grab Standard Penetration Standard Penetration B10WS/6" 13/15/16 11/30/30 Remarks: 2. 3. 4. Test hole located per attached sketch Elevation: existing ground· Date of Exploration: June 16, 1974 Drilling stopped by boulder at 12.0 The seepage area required per bedroom by soil type (per the Greater Anchorage Area Borough) is as follows: Soil Type (Unified Classification) Mn SM SP SW GM GW Soils reqmrir~g Seepage Area Required 275 ~2/bedroom 250 ~2/bedroom 150 ~2/bedroom 125 ft2/bedroom 225 ~2bedroom 85 ~2/bedroom greater than 250 ft2/bedroom are not allowed in seepage pit are~ calculations (per Greater Anchorage Area Borough). The seepage area required at depth can be expressed as follows: Depth Unified SOils Classification Seepage Area Required 0-1.5 1.5-5 5.0-5.5 5.5-12 GM GM ML GP 225 225 Not Allowable 85 D~kin$on Os~vald W~i~/ Lee Page 3 t' Enclosed are some excerpts from State and Borough ordinances which may be of value to you. .For further restrictions, particularly with reference to location of the seepage pit, we call your attention to the Greater Anchorage Area Borough Ordinance 28-68. ~ Please call if we can be of further service. Very truly yours, ALASKA TESTLAB John M. Lambe JML: mm Enclosure Approved: ~ ~ert'ltlea ')'Yell ), · ~or.....~.~. ......... ~-"': ~.~.'i..~.~.~ ........................... ~----:- ................ Location L~~ ....... .t. LI ..:.. D ate completed......~, t~: ;..I ..... :~..~-,...)..~---~--/~- ..................... : ...................... ; ......... r,q.,,, o~,,.d, .... lh~q.!. ~ '.! ........................................................................... Descrivti~n of Formation ":'.'..; ~: ,- ' from to ' I RECEIV.fiD Municipality of Anchorage Development Services Department Building Safety Division On-Site Water and Wastewater Program 4700 South Bragaw St. P.O. Box 196650 Anchorage, AK 99519-6650 www.ci.anchorage.ak.us (907) 343-79O4 CERTIFICATE OF HEALTH AUTHORITY APPROVAL FOR A SINGLE FAMILY DWELLING Parcel I.D, __015- ~l -- Expiration Date: GENERAL INFORMATION Location (site address or directions) ~. t t-I,C~:~ }'(CO Current Property owner(s) ~-ec~.c'~,cc.~ '--~'~.~v,¢(' Lending agency Day phone Mailing address Real Estate Agent Day phone Mailing Address Unless cther, vise requested, HA4 will be held by DSD for pickup. 2. NUMBER OF BEDROOMS: L~ 3. TYPE OF WATER SUPPLY: · Individual Well Individual Water Storage Community Class .~ Well Public Water System TYPE OF WASTEWATER DISPOSAL: Individual On-site Individual Holding tank Community On-site Public Sewer The Municipalit7 of Anchorage Deve!opment Se.vices Department (DSD) Issues Cadi,'icates of Health Authority Approval (HAA) based only upon the representations given in para.cmph 4 by an inde;endent professional civil engineer registered in the State of Alaska. CeP'J~c~tes of He=-[th Authcdl'.¢ Approval ere requ!red for the transfer of title (except between spouses) for prope~es served by a single-family Ch-Site wastewater disposal and/or water supply system. DSD also issues HAAs upon request to hcmeowners. C¢¢,ificates of Health Authority Approval are wlid for 90 days from the date of issue for prcperties served by a pdw-te er Class C we!l and may be reissued with new water sample results. (Certificates may be reissued fcr a pedcd cf up to one year with valid water samples.) Certific=tes are valid for one year for properties served by Class Acr B wells or a pub!lc water system. The Munic!pality of Anchorage is nct res.ccnsible for e.,Tcrs cr omissions in the professicnal engineer's wcrk. 4. STATEMENT OF INSPECTION BY ENGINEE~ As certified by my seal affixed hereto and as of the validation date shown below, I verify that my investigation, based on procedures outlined in the Health Authority Approval Guidelines for this application, shows that the on- . site water supply and/or wastewater disposal system is(are) safe, functional and adequate for the number of bedrooms and type of structure indicated herein. I further verify that based on the information obtained from the Municipality of Anchorage files and from my investiga~Jon and inspection, the on-site water supply and/or wastewater disposal system is(are) in compliance wit,h all applicable Municipal and State codes, ordinances, and regulations in effect at the time of installation. NameofFirm T'~[,~...(~,~,.-~..I,r~[~._c2 '~, ~ Phone Address ~' .~p_.% UZ- {~ J~t ~ [ 0 Engineer's Printed Name "~'~1~1~.~ ~.~ ~,ovV~L~ ~ Date '~'--I~ -0% Conditional a~proval for - bedrooms, with the fgll6w~ng~t~ulations: Additional Comments Attachments: HAA Checklist Septic System Advisory Well Flow Advisory X ~_~..' ON-SITE '-.~? ~.~': WATERAND ; ~ : WASTEWATER .' ~ . PROGRAM .. ..... Maintenance Agreements Supplemental Engineer's Report Other Odginal Certificate Date: "~ - ~. ~z. ~ ...~... Municipality of Anchorage DevelOpment Services Department Building Safety DMslon ' On-Site Water & Wastawater Prngmm 4700 South Bmgaw SL P.O. Box 196650 Anchorage, AK 99519-6650 www.ci.anchorage, ak,us (907) 343-79O4 HEALTH AUTHORITY APPROVAL CHECKLIST LegalDescrlption: ~r~L~>V~ ~i~.~_ C~"~'~E kJ~[~.L. ParcellD:Ol~-,--':S~,t--,~2~' A. I/~LL DATA Totaldep~ )~..~ It. If A, ii, or C provide PW~ID # t'~'/A sanitary seal (Y/N) '~/ Casedto )~ · well Log (Y/N) ~ Wires properly protected (Y/N) ~/ Casing height (above ground) ~'Z_ in. Date of test Static water level Well production WATER SAMPLE RESULTS: FROM WELL LOG ¥, fL g.p.m. AT INSPECTION .ctO fL g.p.m. Coliform colonies/100 mL Amenic: ~ mg./t. B. SEPTICfHOLDING TANK DATA Tank Type/Material Tankaiza 1~..~/,2 gal. Foundation cleanout (Y/N) Date of pumping C. ABSORPTION FIELD DATA Date of ~ample: ~_~ ~- ~,T ~E. t Number of Compartments Depression over tank (Y/N) Pumper Date installed Leng~t ~U fL Total depttl I ~C) lt. Eft. absorption area ... Soil rafing (g.p.d~ a~) ~o ~, Other bacteria ' coloniea/100 mi. Datein=talled ~/~/a~/ High water alarm (Y/N) ~ /~.o~ Monitedngtube 'h/ Date of adequacy teat )~'~/_ uO"- Results(Pass/Fall) ~/ Fluid depth in absorption field before test / in. Water added ~gal. Elapsed TIme: V/min. Final fluid depU1 t~in. Absorption rate >= Any rejuvenation treatment (past 12 mo.) (Y/N & type) ~,~ 0 System type T.-~..~-~' Gravel below pipe 7 fL Depression over field For L// bedrooms New depth ~' ~ g.p.d. If yes, give date D. UFT STATION Date installed 'Pump on' level et Datum F.. SEPARATION DISTANCES in. .,,,~Jglf~r alarm level at Meets elam1 & circuit requirements? SEPARATION DISTANCES FROM WELL ON LOT TO: Septic lank/lift station on lot Absorption field on lot · Public sewer main Server/sep~c sendce line On adjacent lots On adjacent lots Public sewer rnanhole/cteanout Holding tank ' SEPARATION DISTANCES FROM SEPTIC/HOLDING TANK ON LOT TO: Building foundation ' . ~ ProPerty line.~ O AbsOrption field ,.~) Water main ~4/~ Water sendce line -~' 'f Surface water fa Wells on adjacent lots SEPARATION DISTANCE FROM ABSORPTION FIELD ON LOT TO: · pmPertyune l (~ ' : water service line ' ~'~- 'f' Curtain drain · t~;.~ · Bulidlng foundation L,l.~. ~ water main Welis on edjacent lots F. COMMENTS G. ENGINEER'S CERTIFICATION I cerUfy that I have determined through field i~spec~ons end review of Municipal reco~s that the above systems ere in conformance with MOA HAA guidelines in effect on this date. o;te 7-1/- - 02-. HAA Fee $ Date of Payment Receipt Number (Rev. 12/01) Waiver Fee $ Date of Payment Receipt Number in. 68'12'45" F_. ~ 65'47'0g" }'l 377.72 - - AS BUILT LEGEND , LOT 4, ......... =ARr..EL CON'INNS: 74.g,,~,,t: 50. FT. [AS~MENTS ~ R-'COI~D, OTHER IHAN 1HO5[ S$t0'/d~1 ~ RECORDED PLAT NO, 72-2.~, /-~£ NOT s,,-laWl HEREON. NO CO~NERS SET THIS DATE I hereby ce~tlfy thai I ho~e pe~io~med o Ue~tgo~ea's LAKE O' ~ H#Ic: SUBDIVISION Anchoroqe Reco'di~g D~It~'I~, Alos~o, cnd Ibot Une ~'n- p~ovemeflls situated (he~eofl ore ~[h;n the I:.rol:~rly line ¢~d do col overlap or eflc~ooc~ on the prOl>erty Yn<l odjace~t the~el.o, Itml no Imp~oveme3~ll o~ pmp- ertr ly~r~j od;ecenl thefelo enc~ooch on the premises L~)UNSBURY & AS~;~CIAIES, INC. 723 w. 6th Ave. A~ICI40~G~_., ALA~<A 272-5451 GRID 26.39 FIELD 80OK No. 02-1025 f-056 P.OZ/03 102440200t Tobbcn -qpurkl~nd P.E. Let 4, Rk 3, La~ O' t~e I-U~I Lot 4, ~ 3, La!~ O' I~.c H~ All ~te..fl'lmel Irt Ab.da St&ndatd Time Printed Date~'lme 07,/2,,7./'2002 l~:~ Tt<hnlcal DIr~ctar Total R~ul~ Cn!u Method 1.00 mg/L EPA 3~.G Inlt coL"l 0C'."AL SMIB 92228 07/16'02