HomeMy WebLinkAboutELMORE #1 BLK 3 LT 16MUNICIPALITY OF ANCHORAGE Development Services Department Phone: 907-343-7904 On-Site Water & Wastewater Section Fax: 907-343-7997 Pump Installation Log Well Drilling Permit Number: _______________ Date of Issue: ____-____-____ Parcel Identification Number: ____-____-____ Legal Description Block Lot Property Owner Name & Address: Pump Installation Date: _____-_____-_____ Pump Intake Depth Below Top of Well Casing: __________ feet Pump Manufacturer’s Name: ___________________________ Pump Model: _____________________________________ Pump Size: ____________hp Pitless Adapter Burial Depth: _________ feet Pitless Adapter Manufacturer’s Name: ________________________ Pitless Adapter Installer: ____________________________ Well Disinfected Upon Completion? XX Yes No Method of Disinfection: _____________________________ Comments: Pump Installer Name: __________________________________ Company: ___________________________________________ Mailing Address: ______________________________________ City: ___________________ State: __________Zip: _________ Attention: The pump installer shall provide a pump installation log to On-site within 30 days of pump installation. Mun icipality of Anchorage On-Site Water and Wasteirvater Section , (907) 343-7904 Sru.SITE WAST'EWATER IN$PFCTION RFPCRT permit Number: OSP201031 oltr-l.l1_50 PlDNumber: CIffi Dwelling: @ Singte Family (SF) ! with ADU fJ Duptex (D) f Two Single Family Project: [ ruew ffi Upgrade Page 1 of 3 hlenre CIJRISTINA JENNINGS ABSORPTION FIELD I Deep Trench I Wide Trench I I ottrer Sile Address 4360 SHOSHONI AVE "ANCHROAGE, AK 99516 Phorre 9A7-287-s852 Number of Bedrooms 4 Soil Rating GPD/SF T olal deOt\pfn orig rnal grade ,f Ft. LEGAL DESCRIPTION Deplh to oioe invert kcm originat Srag,l ,{ Fi Gravel depth beneath pipe Ft.Subdivision Block Lol ELMORE #1: BLOCK 3 LOT 16 Fill added abor.,e originat ggd€ fFt Ft Gravel length Tol',,nship Range Section Gravelividth Tt. Beds: rrlumber of Lines Distance belween lines F1S EPARATI O N D IST, Td CES To, Sepijc ' Absorptron i Lift Sration Halding Se.e;er Fronr Tank , Field Tank Line ,;y,^,on ',u" 0,, tdunrber of trenches Fr. Dist. between trenches .90#Well TATJK E Seplic D S.T.E,P f t-totoins f, Orner fi/anufaciurer GREER TANK Capacity 1500 Gar. NA Surface \llater "60'&) Lot Line tulaterial HDPT Number of compartments 2 Foundation 10'+LIFT STATION Manuiaciurer Capacity Gal.Remarks OLD TANK DECOM1UTSSIONED pER UpC PER CCNTRACTOR -WR#OSVZO1O.1 1 Alarrl location Electrical insialled by lnstaller ARM SEPTIC SERVICES PIPE FIIATERIAL iiouse io rankEI]!itS o]iffi !x!34 Drai6fielcl 0303l/E;^1{sirNG CO/MTD3034 nspector DAVID GARhJESS, PE ANID TIM ECKLUND BENICH MARK (Rssunrectetevationl 100.20 fr lnspection t3l27lZCZ0 ._dates: ztr 3,u:-"'- 4rh -*=-------- Location and description TCP CF' niTF-i AND WASTEWATER SECTION APPROV,AL Date Engineer's StON-$ITE WATER onditional Approiral: Septic System Ap p roved --. <'-' l'-rl'rtt ' - --:\ 5.+\r "_..\J .:::. i r; ,i . .t irii _ / 'ltl in;P*'rt a t, ' l,) .1., !z' -<: !-'' ii .i. *. rir._ I t ,1,. . - _t:Il .-)t-. ^..,i\':.=' 'a=, i! .'i.) 't..', ,i: './/l,/ '*rr^ 0" Note. this approval does not inclucle well permit requirements, lRev 05,/02i 16) ,-/ PERMIT NUMBER: PARCEL ID NUMBER: OSP201031 RECORD DRAWING 018-171-50 \ AB ra --- —— — — — — — — — — — — — — — — — \ DBL1 65.9 67.3 DBL2 65.8 67.7 MH 64.6 69.9 ST1 64.5 73.2 DBL3 64.5 74.4 DBL4 64.6 75.1 ° a \ NEW 1500 GALLON HDPE GREER TANK' I I 100' WELL RATED FOR 10' BURIAL - DOUBLE 4 a I I CLEANOUTS INSTALLED BEFORE AND AFTER TANK; CONNECTED TO EXISITNG ° p SEWER LINE BEFORE AND AFTER TANK; H 1 n ° Jyp� EXISTING NEW CLEANOUT WAS INSTALLED AT THE HOME / BEGGINING OF THE WEST TRENCH \ / EXISTING SEWER LINE \ / o M 0 � ASSUMED LOCATION OF EXISTING SEWER LINE / w SUMP All. GQ� NATRONA AVENUE ELMORE #1; BLOCK 5, LOT 2 ELMORE #1; BLOCK 5, LOT 3 VACANT CAl ...�&\\s\ II OF GARNESS ENGINEERING GROUP, Ltd l ......9 . ENGINEERING SALES CONSULTING 3701 E. TUDOR ROAD, SUITE 101'ANCHORAGE, AK99507-PHONE (907)3375779- FAX (907)339-3246'WEB SITE: -gamessengineenng.cam 0........... /' ����„�,���� ,� �/ PREPARED FOR: PHONE NUMBER: PAGE NUMBER: CHRISTINA JENNINGS 907-287-3852 2OF3 /�j�•'.,e y. Games.. :emsA LEGAL DESCRIPTION: DRAWN BY: • # C 79 �' • •,\� ELMORE #1; BLOCK 3, LOT 16 D.J.G. • TYPE OF WORK: DATE: LICENSE♦1•N FESS��P�•• � SEPTIC TANK RECORD DRAWINGS 4/10/2020 #AECC884 I�%�������� i PERMIT NUMBER: PARCEL ID NUMBER: OSP201031RECO018-171-50 TOP OF MANHOLE = 100,20 FINAL GRADE = 100.02-100.54 MH ST2 2" INSULATION PER CONTRACTOR TOP OF TANK AT INTLET = 95.94 TOP OF TANK AT OUTLET = 95.95 NEW 1500 INVERT OF BUNG AT INLET = 95.30 GALLON H. D. P. E. INVERT OF BUNG AT OUTLET = 95.13 SEPTIC TANK A HIGH WATER ALARM FOR THE SEPTIC TANK WAS INSTALLED AS REQUIRED BY THE MOA FOR APPROVAL OF THE WAIVER FOR SEPTIC TANKAND DRAINFIELD TO SURFACE WATERS - SEE ATTACHED EMAIL FROM ARM SERVICES REGARDING THE BURIAL OF THE ELECTRICAL LINE FROM THE TANK TO THE HOUSE Ilk OF 011 Tp GINEERING"R GARNESS ENG u Ltd ....::.......... ... ,................. 0 ENGINEERING SALES CONSULTING 3701 E. TUCOR ROAD, SUITE 101 ' ANCHORAGE, AK 09507 • PHONE (907) 337-GM • FAX (907) 3363246' AEI]SITE', mwi.0arnessen9irwenr3.rnm ...,• . • �, ... e1... .. ... 10 PREPARED FOR: PHONE NUMBER: PAGE NUMBER: y G8 SS CHRISTINA JENNINGS 907-287-3852 3 OF 3 ®��i CES JAw LEGAL DESCRIPTION: DRAWN BY: •. •• [ •`1� ELMORE #1; BLOCK 3; LOT 16 D.J.G. TYPE OF WORK: DATE: LICENSE FES 4/6/2020 SEPTIC TANK PROFILE 4/6/2020 #AECC884 ®�®®��� in ,O,OZ in 0 0 19.0 L w W W o # O � o O Qw LLX 0w M N ,5£ o ,0'6 w a ,0'9£ Ow Y O N 'COX) � o ^/ 3 0 V ,0'tiZ 0 z U)V) Z OI.- 0w Q O O�� 0 U �0 U 0 >_ao Z o¢¢ 14 W<Im L�l co CO � i cn CID 0 M �Of : I L' i i= -I Q- C) -- v F I v i ° \ ' J ' 0 N 00007'06" W 178.71' \ N 00007'06" W 178.71' s° S 00007'00" E 178.71' 30' I w I C6 \ 30' I 30' i co I i o 55.2' UJ N Q r tilt I 0 010 ( l3 mw 641' � W '�ti�.���d ���i\,,/ W �% NI I w N Z� N �J�s� �i�� b�1i� \ I N ?:lwl LU 0 M 0� Mlvwicwn( JQ _ 0 \Z M \�c' /� ISM U — co a d' h 0 Cl)Qom:::: wJ U) 0_ ° Q ° 1 00 00 H F-�r C4 I co o( o r �' d U) I to O // / l b Z CV uwio I I � M I 30 — — — — -------- 30 I 30 ------ — — — — -----) 10' UTILITY EASEMENT:.'.'.;_:: 10' UTILITY EASEMENT Eo E❑ 10' UTILITY EASEMENT S 00007'06" E 178.71' N 00007'06" W 178.71' N 00°07'00" W 178.71' cqo I p o 0 0 J w wC0 w U m a o m LO Y Z g 0U o # zz wr QOC Qw Q 0w 04 o U - COCO O U Wcn- N N (� �= Cl) O}z >C7 HzC6 wzW (nJ=J(!) _j J Ooi=p co =Z OJ0 in F} ~w d Itz w aX �� -i--1 00 Z�W Wm Q �— co w w = z0 ¢z �i�OU O = LL m I'J MO of WIL IL Oo zU W �O (n U-U.U� F - WQ�Ww_U o W Zcn Q �w Op W F— za Ill U) m to WF- mm UJ0 �Q�tw=-1Q �W �, Z HQ DOUM >-w - F- III =� 0 www M� =Yptd D= W w> _DIX O o -j UUww>W zgaWoX wU F- X c.2 _0CL JW QQ�Qzw oQ E -i� v F I v i ° \ ' J ' 0 N 00007'06" W 178.71' \ N 00007'06" W 178.71' s° S 00007'00" E 178.71' 30' I w I C6 \ 30' I 30' i co I i o 55.2' UJ N Q r tilt I 0 010 ( l3 mw 641' � W '�ti�.���d ���i\,,/ W �% NI I w N Z� N �J�s� �i�� b�1i� \ I N ?:lwl LU 0 M 0� Mlvwicwn( JQ _ 0 \Z M \�c' /� ISM U — co a d' h 0 Cl)Qom:::: wJ U) 0_ ° Q ° 1 00 00 H F-�r C4 I co o( o r �' d U) I to O // / l b Z CV uwio I I � M I 30 — — — — -------- 30 I 30 ------ — — — — -----) 10' UTILITY EASEMENT:.'.'.;_:: 10' UTILITY EASEMENT Eo E❑ 10' UTILITY EASEMENT S 00007'06" E 178.71' N 00007'06" W 178.71' N 00°07'00" W 178.71' cqo I p o 0 0 J w wC0 w U m O mo co= 0� z >. <Z wua w °auj w °w a' wz III z 3: wm u W� o U)0 > U)(n _co zz wr QOC Qw 0w 04 00 ((nnW �Z F -w00 O}z _Z Qm Z z z (n W co / CO Itz Z� �� �¢ L) �� O~ Q w w o Ln z Q z U LL W F- 0 W WIL IL Oo zU W �O UU w ZDQ Zcn W — W cn z to (=n HQ DOUM H W W z 0 U 0 z POST IN A CONSPICUOUS PLACE ALL WORK MUST BE INSPECTED Field Inspection Re uest r uked 2 Workingda ys in.�, days In advance for imai inspeciton. Call (907) 343-8206 (Voice reoo dof ei} for Scheduling. and n5 Permit is not Valid without the call-in and also must include the on number. e call ticket (u011ty locate) MUNICIPALITY OF ANCHORAGE - RIGHT OF WAY DIVISION 4700 ELMORE ROAD TELEPHONE (907) 343 RIGHT OF WAY PERMIT 8240 FAX (907) 343-8250 Type: Encrch not Status: Issued Date Applied: 03/1712020 Date Issued: 03!1712020 Construction Start Date: Last Updated: 04/07/2020 Permlrte 1: Susan S Cioe ,,,,,cnr O r. 31 l)e.pal'tIII ent R201133 Grid: SW3036 Issued By: claudia,pinard Last Updated By: PWMSW Work Orders Utility: Contact Person: Christina Jennings, 707-287-3852 Primary Inspector: AddresslLoc: 4360 SHOSHONI AVE, Anchorage _ @ Elmore Road Legal Description: ELMORE #1 SLK 3 LT 16 G:3036 Original Work Description: The septic pipe and leach field encroaches 15' into the Natrona Avenue Right of Way. Sum ktsn^ze �rncial Tra a +r��= Fer. Descriot[Qll Permit �-� Lmount 1 $120.00 Total Fees: $120.00 See ravOrse for rcquirsmontsfremarks. I have read and understantl,'bolh sides of Vis permit. I. gree to the terns and conditions; and I certify that all work � and municipal codes an reg bons �Itd he�irovision�f this permitvpU comply with federal, state, Signature: :. '�, I rJ �'L(�, r ; fl,� Lit (� % i rd %L hgi�CL() Construction Requirements and Notes: 1. This permit has been issued based on the assumption that the information contained in the pals and supporting documentation is correct. Any and all omissions are the responsibility of the permitee. Any change in the scope of work requires a revised or new permit and Traffic Control Plan (TCP). 2. Contractors' acceptance of this permit constitutes acceptance of the Municipality's bonding requirements, and is contractor representation that contractor has and will comply with those requirements. Unless a specific bond is applied to this permit by written reference, the contractor's performance bond on file with Development Services, Right of Way Enforcement, shall suffice as the required bond. 3. The Permittee shall post a copy of the permit in a conspicuous location at the place to which the permit pertains before any work there is started and shall remove the permit only after the Right of Way Inspector has accepted the work as being in compliance with the permit. 4. The Municipality has the right to inspect and/or reject materials and workmanship not to Municipal standards, to stop work until corrections are made, or to require removal of the facility and to charge time, material and equipment to the Permitee to correct the facility if they fail to comply with the conditions of the permit. 5. Permitee is responsible for locating and protecting all utilities and survey markers in the work vicinity. For utility locates, call Alaska Digline at "811" or (907) 278-3121. 6. The contractor shall erect signs, barricades and detours in accordance with the U.S. Department of Transportation "Manual on Uniform Traffic Control Devices", Part VI — Traffic Controls for Street and Highway Construction, Maintenance, Utility and Emergency Operations. Failure to do so may result in fines being assessed under Title 14 for work not in conformance with a permit. 7. Changes in the approved road closures or scope of work resulting from emergency circumstances may be allowed during construction. It shall be the responsibility of the contractor to notify the Permit Office, 343-8206, and/or obtain an approved Traffic Control Plan (TCP). It shall be the contractor's responsibility to notify the following agencies: Fire Dispatch 267-4950, Police Dispatch 786-8900, Alaska State Troopers Dispatch 269-5511, People Mover 343-8253 and School Bus 742-1207 or 742-1209. 8. All construction shall be in accordance with the current edition Municipality of Anchorage Standard Specifications (MASS), applicable municipal codes and regulations and the approved drawings and special provisions of this permit. 9. As a condition of this permit all excavations will conform to the standards outlined in OSHA 29CFR, 1926 Subpart P. 10. The Right of Way shall be restored to the same, or better condition, than it was prior to the contractors' work being performed. The work shall be performed diligently and continuously, until completed to the satisfaction of the Municipal Right of Way Inspector. 11. All underground installations within a public place shall be buried at a minimum depth of forty-two inches (42") below the final surface elevation, i.e. bottom of drainage ditches, road shoulder or finished grade. 12. Permanent paving, recycled asphalt pavement (RAP), chip seal, sidewalks and curb and gutter must be replaced within 7 working days after underground work is completed. 13. Winter Condition Requirements (applicable to all Right of Way Permits). a. No trenching and or excavation is allowed within the road prism except for emergency repair of existing utility facilities or by approval of the Director of Development Services. b. Crossing of the road prism shall be by boring technology. c. No frozen material shall be placed in the excavation as fill and/or backfill. A source of non -frozen fill and/or back fill material shall be available. d. All frozen ground within the Right of Way shall be thawed prior to excavation. — CH- q "I ------------ 1_� March 13, 2020 Susan Reed 4360 Shoshoni Anchorage, Alaska 99516 Subject: Letter of Non -objection for Septic System in Road Right of Way Lot 16, Block 3, Elmore Subdivision Addition #1 NW'/4 of Section 34, T I 2NI R3 W, S, M., Alaska Grid 3036, O820003, PID #018-171-50 Dear Ms. Reed: 0 G )0 00 z (�() 3 3y 13 Chugach does not object to the existing septic system within the road right of way of Natrona Avenue on the south side of Lot 16, Block 3, Elmore Subdivision Addition #l, as shown on the as - built survey performed by Fixed Height, LLC, dated January 17, 2020. Please note that Chugach has overhead electric facilities within the western 10' of the road right of way. It must be your understanding that the installation within the road right-of-way is at your risk. This non -objection is given without prejudice to Chugach's full enjoyment of any and all rights it may have in and to such road right-of-way area. All work within the road right-of-way must be in accordance with the enclosed Electrical Facilitj, Clearance Reilitirentenn. Also enclosed for your use and information is the 811 Alaska Dig Line utility locate call center card, and Chugach's What is an Easement? handout. If you have any questions, please call Claudia Roberts, Right -of -Way Agent 11, at 762-4646. Sincerely, Karen Keesecker, SR/WA Manager, Land Services Chucach Electric. Associaiior, �'rc, 5bU 1 bedron 06ve, PG B,, J1 9,-,jCQ "63(y 9�Z5 I �, ' - (907j 5637494 fax 1907),562,5)2,7 - (80c)] 473.7494 wwwchu cchelccitic.ccrn a a&,@CIIjgUCIIq1PCIriC March 5, 2020 Susan S Reed 4360 Shoshoni Ave Anchorage, AK 99516 Re: Septic System Encroachment To whom it may concern: ENSTAR Natural Gas Company A DIVISION OF SEMCO ENERGY Engineering Department Right of Way Section 401 E. International Airport Road P. 0. Box 190288 Anchorage, Alaska 99519-0288 (907) 277-5551 FAX (907) 334-7798 ENSTAR Natural Gas Company has no objection to the septic system encroachment within the Natrona Avenue sixty feet (60 FT) wide road right-of-way adjacent to the South property line of Lot 16, Block 3, Elmore Subdivision Addition No. 1, according to Plat No. P -635A, Records of the Anchorage Recording District, Third Judicial District, State of Alaska. Acceptance and use of this letter of non -objection by yourself, your heirs, your assigns, or your successors, will constitute agreement to the following stipulations: • Landowner/Contractor working near ENSTAR gas facilities shall contact the Alaska Digline, Inc., (907) 278-3121 or 811 for line locating two (2) business days prior to any related excavation. This service is free of charge. • ENSTAR will be held harmless, now and forever for any damages or injury to any person or property as a result of this encroachment. ® Any ENSTAR facility damaged or destroyed, as a result of this encroachment will be repaired at no cost to ENSTAR. • Any costs incurred by ENTSTAR for special construction necessitated by this encroachment will he home by the land owner. o All applicable safety code regulations will be observed and maintained. • This letter of non -objection will in no way preclude ENSTAR from full use and enjoyment of its rights within any portion of its right-of-way. Sincerely, Cassic Acres DocuSign Envelope ID: 799D37F5-8034-404A-8845-17BD7CFOE632 March 9, 2020 Christina Jennings 4360 Shoshoni Ave Anchorage, Alaska 99516 Alaska Communications has no objections to the proposed septic system encroaching into the 10' Utility Easement located along the northern boundary of lot 16, block 3 Elmore #1 Subdivision, otherwise known as 4360 Shoshoni Avenue Anchorage, Alaska, as depicted on the drawings provided by Gamess Engineering Group. Alaska Communications currently utilizes this easement and has no objections to the encroachment. Alaska Communications hereby issues this letter with stipulations to allow the encroachments of the above mentioned into the easement. Acceptance, (your signature below), and use of this letter of non -objection by yourself, your heirs, your assigns, or your successors, will constitute agreement to the following stipulations: 1. Alaska Communications will be held harmless, now and forever, for any damages or injury to any person or property as a result of this encroachment. 2. Any Alaska Communications facility damaged or destroyed as a result of this encroachment will be repaired at no cost to Alaska Communications. 3. Any costs incurred by Alaska Communications for special construction necessitated by this encroachment will be bome by the property owner. 4. All applicable safety code regulations will be observed and maintained. 5. This letter of non -objection will in no way preclude Alaska Communications from full use and enjoyment of its rights within any portion of this easement 6. Alaska Communications is under no obligation to restore any structure damaged as a result of Alaska Communications full use and enjoyment of its rights within any portion of easements or right-of-ways. Please sign both copies, retain one copy for your use and return the other to Alaska Communications, S'ely, FktE k4�r Network Engineer Il, Outside Plant Alaska Communications Outside Plant Engineering, MS#14 600 Telephone Ave. Anchorage, AK 99503 SIGNATURE: D3A�TEq;c17 p 4 p td.S1RtA, �. �,Gt�t. �tt t �trtlA. ,�t.Ltdll.E4t.�Y�9�il:�PU1.Gtf [tA.l�G� 0612AD1 D7368474... Grid SW3036 RCWC DocuSign Envelope ID: 799D37F5-8034-404A-8845-17BD7CFOE632 Christina Jennings 4360 Shoshoni Avenue Anchorage, AK 99516 To whom it may concern, Subject to your agreement to indemnify the company as set forth below, GCI Communication Corp has no objection to the septic tank encroaching into the road and/or T&E easement of B3 L16 Elmore #1, also known as 4360 Shoshoni Avenue, city grid 3036 GCI WO#20-0006-07. This letter of non -objection in no way precludes GCI Communication Corp from full use and enjoyment of any rights it may have within any portion of the utility easement and or the right-of-way, including unlimited access for servicing its facilities. Also, any additional and extraordinary costs incurred during any future required construction, repair or reconstruction of GCI's facilities to accommodate any or all the encroachments shall be paid by the property owner. By signing below, you agree to indemnify and hold GCI Communication Corp harmless, now and forever, for any damage, costs, expense (including reasonable attorney's fees), liabilities and injury to any person or property occurring as a result of the encroachment. Please indicate your acceptance by signing and returning this letter to me at the address below. Sincerely, "Oe Markus 0/ K1' f 6X id fl.i' Sr. GCI Communication Corp 5151 Fairbanks St. Anchorage, AK 99503 907-868-6168 Office 907-868-8580 Fay DocuSigned by: St/91ate 7368474 0 272 1 4:14 PDT Date MUNICIPALITY OF ANCHORAGE On -Site Water & Wastewater Program PO Box 196650 4700 Elmore Road Anchorage, Alaska 99519-6650 Phone: (907) 343-7904 Fax: (907) 343-7997 http://www.muni.org/onsite On -Site Wastewater Disposal System Permit Permit Number: OSP201031 Work Type: SepticTank Upgrade Tax Code Number: 01817150000 Site Legal Address: ELMORE #1 BLK 3 LT 16 G:3036 Site Mailing Address: 4360 SHOSHONI AVE, Anchorage Owner: REED SUSAN S Design Engineer: GARNESS ENGINEERING GROUP LTD This permit is for the construction of: ❑ Disposal Field ❑✓ Septic Tank ❑ Holding Tank ❑ Privy Effective Date: Expiration Date: Lot Size in Sq Ft: Total Bedrooms CI]r Is . e Department 3/24/2020 3/24/2021 37299 ❑ Private Well ❑ Water Storage All construction shall be in accordance with: 1. The attached approved design. 2. All requirements specified in Anchorage Municipal code Chapters 15.55 and 15.65 and the State of Alaska Wastewater Disposal Regulations (18AAC72) and Drinking Water Regulations (18AAC80) 3. The wastewater code requires inspections during the installation. The engineer shall notify the Development Services Department per AMC 15.65. Provide notification by calling (907) 343-7904 (24/7). 4. From October 15 to April 15, a subsurface soil absorption system under construction during freezing weather shall be either: a. Opened and Closed on the same day, or b. Covered, sealed, and heated to prevent freezing Special Provisions: 1. Prior to IR approval, an Access Agreement for the driveway is to be obtained. 2. Prior to IR approval, the engineer is to confirm that the tank has a high water alarm. 3. Prior to a COSH, an encroachment permit from ROW is required for the field in the ROW Received B) Issued By: Date: zd Date: ZO i 5 nzcn t _ Municipality of Anchorage Ur.pnrt.ment P.O. Box 196650 ® 4700 Elmore Road Anchorage. Alaska 99519-6650 a (907) 343-7904 ® Fax (907) 343-7997 http://www.muni.org/Onsite Development Services Division On -Site Water and Wastewater Program x x x x VARIANCE/WAIVER REVIEW x x x x Waiver#: OSV201011 COSA#: Permit#:OSP201031 PID#: 018-171-50 Legal Description: Elmore #1 Blk 3 Lt 16 Engineer: Garness Enqineerinq Group Your request for a waiver of the required 100 feet horizontal separation from the absorption field and septic tank to the surface water has been approved. The approved separation distance is 60.0 feet. In addition, the tank may be 90 feet from the well and the field at the southern lot line. This waiver approval applies to the existing absorption field and septic tank only. Any future upgrade to the on-site wastewater disposal system will require all separation distances be met or another approval from this department. ............................................... ■ ............................. ■ 1 Waiver is Granted: X Waiver is not Granted: Date: Approved by: Name of Revie .......................................................... .................. t **** VARIAN C E/WAIVER REVIEW **** Community Development Department Phone: 907-343-7904 Development Services Fax: 907- 343-7997 On -Site Water & Wastewater Program Mayor Dan Sullivan On -Site Sewer/Well Permit Application For A Single Family Dwelling Parcel I.D. 018-171-50 Property owner(s) CHRISTINA JENNINGS (POWER OF ATTORNEY) Day phone 907-287-3852 Mailing address 4360 SHOSHONI AVENUE `ANCHORAGE, AK 99516 Site address 4360 SHOSHONI AVENUE *ANCHORAGE, AK 99516 Legal description (Sub'd, Block & Lot) ELMORE #1; BLOCK 3, LOT 16 Legal description (Township, Section & Range) Lot Size Sq. Ft. Number of Bedrooms APPLICATION IS FOR: ( ® all that apply) Absorption Field ❑ Septic Tank Holding Tank ❑ Privy ❑ Private Well ❑ Water Storage ❑ APPLICATION IS AN: Initial ❑ Upgrade Renewal ❑ THIS APPLICATION INCLUDES A VARIANCE/ WAIVER REQUEST FOR: TYPE OF DEWELLING: Single Family (SF) (w/wo ADU) Duplex (D) ❑ Multiple Dwellings ❑ (SF and/or D) DRAINFIELD TO LOT LINE; DRAINFIELD TO SURFACE WATERS; TANK TO WELL Distance: 0 FEET; 60 FEET; 90 FEET I certify that the above information is correct. I further certify that this is in accordance with applicable Municipal codes. GARNESS ENGINEERING GROUP, Ltd. (Signature of property owner or authorized agent) Permit/Rush Fees: Date of Payment: Receipt Number: Permit No. Waiver Fees: Date of Payment: Receipt Number: Waiver No. (Rev. 01/11) GARNESS ENGINEERING IJ , Ltd ENGINEERING - SALES, CONSULTING 2t� March f6, 2020 Municipality of Anchorage Development Service Department On -Site Water & Wastewater Program 4700 Elmore Road Anchorage, AK 99507 Ref: Proposed Septic Tank Upgrade for Elmore #1; Block 3, Lot 16 To whom it may concern: The subject lot is served by a private well and septic system. Per MOA records, the existing septic tank is 36 years old. Per MOA memorandum, a septic tank of this age should be physically inspected and/or replaced prior to COSA approval. Based upon this fact, we are proposing to replace the septic tank. We are proposing to decommission the existing septic tank per UPC and install a new 1500 -gallon HDPE Greer tank rated for 10' burial. See attached design drawings for tank location and other MOA requirements. In addition, the existing drainfield encroaches upon the creek to the south. We are requesting that your department issue a variance from tank and drainfield to creek of 60 feet and drainfield to lot line down to 0 feet. We are also requesting that your department issue a variance from the new septic tank to the well down to 90 feet. Justifications for granting this waiver is as follows: • The encroachment has existing for approximately 36 years. • The area between the tank and drainfield to the creek is vegetated. • The septic tank will have a high-level alarm float installed. If the drainfield were to become surcharged, the tank would also become surcharged, triggering the alarm and notifying the homeowner. In theory, effluent would not overflow form the drainfield as the alarm would sound prior to effluent daylighting. • The home is located between the well and the drainfield. If effluent were to overflow, it would not travel directly towards the well head. • Water samples were pulled. The nitrate results were 3.78 mg/L. The existing tank is steel and encroaches on the well. The proposed tank will be HDPE. In short, the proposed tank will be an improvement on the existing tank. We are requesting letter of non -objection for the drainfield be submitted with the record drawings and/or COSA. We are unaware of any adverse impacts this installation would have on adjacent wells or septic systems. If you have any questions, please contact us at 337-6179. Thank you for your assistance. 3701 East Tudor Road, Suite 101 * Anchorage, Alaska 99507-1259 Phone: (907) 337-6179 * Fax: (907) 338-3246 * Website: www.garnessengineering.com Ll __ / \`\ SHOSHONI AVEN E a N � ELMORE 91; BLOCK 3, LOT 3 \E� / ELMORE #1; BLOCK 3, LOT 2 VACANT PER MOA RECORDS \ ELMORE#1; —_--_ — BLOCK 3, LOT 4 G----- ------ WELL I VACANT PER jI MOA RECORDS I ELMORE 91; BLOCK 3, LOT 15 \ �I ELMORE #11; BLOCK 3, LOT 17 F mi\� zI-- I ---------------Ur��ATfRONA AVENUE ELMORE #1: BLOCK 5, LOT 2 ELI #1; BLOCK 5, LOT 3 ��z� ELMORE #1; BLOCK 5, LOT 4 VACANT 2a• 0�a`��P' � 4 ry N COULD NOT LOCATE WELL - PER MOA RECORDS, THIS LOT IS BELIEVED TO BE SCALE: SERVED BY WELL ON LOT TO THE WEST (BLOCK 5, LOT 1) 1" = 100' 110) 'Q .w �. .. �� A NESS NEE J , Ltd •4`9 , •� •• ENGINEERING- SALES ,. CONSULTING118 3701 E. TUDOR ROAD, SUITE 101 •ANCHORAGE, AK 99507 • PHOFE (907) 337-6179 • FAX (907) 338-3246 • WEBSITE: yr .gamessengineeringxom®.•••.,. 1 •; - r ;{ •- tt..�....... ............. ®Cr '; '�1 fffey1.•Gar eSS m PREPARED FOR: PHONE NUMBER: PAGE NUMBER. CHRISTINA JENNINGS 907-287-3852 1 OF 2 .: # G'i / " #® J, (, CES -795'3 :'�� Al #® (��• ,. 3;.2• i �c- ��w PROJECT/LEGAL DESCRIPTION: PRAWN BY: ELMORE #1; BLOCK 3, LOT 16 D.J.G. �® FO •... .•• �® ®®�P080®S®�S`® • TYPE OF WORK: SEPTIC SYSTEM DESIGN UPGRADE DATE: 2/20/2020 #Aeccae4 4 *W GEG, Ltd. HAS AN 8 PAGE SPECIFICATION LETTER PRIOR TO THE DESIGN,. ARM SERVICES, LLC. CAMERA'D THAT PERTAINS TO THIS DESIGN. BY PROCEEDING d AND LOCATED THE DRAINFIELDS. IN ADDITION, THEY FORWARD WITH THIS INSTALLATION, THE \ a. INSTALLED A CLEANOUT AND MONITORING TUBE AT ENGINEER, WELL DRILLER, CONTRACTOR AND NORTH ENDS OF EACH TRENCH. PROPERTY OWNER AGREE THAT THEY HAVE READ THESE SPECIFICATIONS AND AGREE TO ACCEPT THE TERMS AND CONDITIONS OUTLINED. C r d.. I• d a a°' a as . . mLISTINGmVEWAY d c m s a m i EXISTING TANK TO BE DECOMMISSIONED PER UPC; CONTRACTOR TO ENSURE PROPER COMPACTION OF SEWER LINE OVER EXISTING TANK TO LIMIT BELLIES IN THE SEWER LINE DUE TO SETTLING OF THE EXISTING SEPTIC TANK AREA• ./ �o"y EXISTING 4 °'v \ BEDROOM HOUSE PROPOSED1500 ALLON HDPE GREER TANK RATED FOR 10' BURIAL; INSTALL DOUBLE CLEANOUTS BEFORE AND AFTER TANK; SHED CONNECT TO DRAINFIELD AT EXISTING SEWER LINE; SEPTIC TANK \ MUST HAVE A HIGH LEVEL ALARM FLOAT INSTALLED THAT IF THE LIQUID LEVEL RISES ABOVE THE DESIGN OPERATING LEVEL BY MORE THAN 2 INCHES, THE ALARM WILL SOUND. PROVIDE SJE RHOMBUS "XPERT ALERT' SYSTEM. -)Uivir *I SUMP #2 / APPROXIMATE LOCATION OF EXISITNG DRAINFIELD; DRAINFIELD WAS LOCATED N BY ARM SERVICES, LLC \ NATRONA AVENUE\\(NOT INSTALLED) SCAl W. - ENGINEERING �SALES -�CONSULTING,.a •-'---, -.. - 3701 E. TUDOR ROAD, SUITE 101 • ANCHORAGE, AK 99507' PHONE (907) 337-6179 • FAX (907) 338-3246' WEBSITE: www.gamessengineeMg.00m PREPARED FOR: I PHONE NUMBER: PAGE NUMBER: CHRISTINA JENNINGS (POWER OF ATTORNEY) 1 907-287-3852 2 OF 2 PROJECT/LEGAL DESCRIPTION: DRAWN BY: ELMORE #1; BLOCK 3, LOT 16 D.J.G. TYPE OF WORK: DATE: �,_ DESIGN OF SEPTIC TANK UPGRADE 2/20/2020 �®m ® P••••.11-4,1111 AV i AV r .49IH .l.........�........9 o..�.............................. ....... �j ... ®®� %dTley�A. GarDess% :• ®®s VCE=7 953' •2m LICENSE®FdS®®off®®®` #AECC884 i SGS Ref.# 1200478001 Client Name Gamess Engineering Group, Ltd (GEG) Project Name/# Elmore #1; B3, L16 Client Sample ID Elmore #1; B3, L16 Matrix Drinking Water Sample Remarks: Printed Date/Time 02/12/2020 15:14 Collected Date/Time 02/04/2020 15:30 Received Date/Time 02/05/2020 14:32 Technical Director Stephen C. Ede Allowable Prep Analysis Parameter Results LOQ Units Method Container ID Limits Date Date Ioit Metals by ICP/MS Arsenic ND 5.00 Waters Department Total Nitrate/Nitrite-N 3.78 0.200 Microbiology Laboratory E. Coli Negative 1 Total Coliform Negative 1 ug/L EP200.8 B (<10) 02/10/20 02/11/20 DMM mg/L SM21 4500NO3-F C (<10) 02/11/20 EWW 100mL SM219223B A 100mL SM219223B A 02/05/20 M.A. 02/05/20 M.A.  t~"~ MUNICIPALITY OF'ANCHO~4AGE ,.~ DEPARTMENT OF HEALTH & ENVIRONMENTAL PROTECTION " .ENVIRONMENTAL ENGINEERING DIVISION 825 L Street- Anchorage, Alaska 99501 Telephone 264-4720 ON-SITE SEWAGE DISPOSAL SYSTEM AND/OR WELL INSPECTION REPORT NAME , IPHONE MAILING ADDRESS LEGAL DESCRIPTION LOCATION NO. OF BEDROOMS Well Absorptwn area P RMIT ~Menuf~turer ~,~ Materiel~. e N°' °f comrrtme"ts ~ ~ell Foundation Nearest lot hne ~ Well ~ation Nearest lot llne ~ DISTANCE TO: ~ ~less Depth Driller ~t line PERMIT NO. ~ DISTANCE TO: Building foundation Se~r line Septic tank ~rea(s) SOIL TEST RATING N ~ REMARKS Permit ~ Applicant: .~A_ '~ Location: _.MUNICIPALITY OF ANCHORAGE~ . Department~ Health and Environmenta' ~rotect$on 825 '._' Street, Anchorage, AK. .4501 ' 264-4720 ~3da~3 ' # ~ HANDWRITTEN PERMIT ~ ' e ~ ON-SITE SEWER ~ ~C~ ~F~ ~iling Address: Phone N~er: ,qq~--Io~ Legal Description: Zo~ It~ ~K 3 ~/~o~n S/D Lot Size: T~e of Soil ~sorption System Is: Trench: / Drainfield: Seepage Bedt Holding Tank: Max~ N~ber of Bedrooms: ~ Soil Rating(sq.ft/br) The Required Size of the Soil Absorption System Is:' DEPTH ~Ot LENGTH ~O' GRAVEL DEPTH ~'/ WIDTH The length dimension is the length(in feet) of the trench or drainfield. The depth of a trench or pit is the distance between the surface of the ground and the bottom of the excavation(in feet). There is no set width for trenches. The gravel depth is the minimum depth of gravel between the outfall pipe and the bottom of the excavation(in feet). ~ ~ REQUIRED SEPTIC(HOLDING) TANK SIZE = /2~-o GALLONS Permit applicant has the responsibility to inform this department during the installation inspections of any wells adjacent to this property and the number of residences that the well will serve. ' ' ' TWO(2) INSPECTIONS ARE REQUIRED # ~ ~ Backfilling of any system without final inspection .and approval by this departmen will be subject to prosecution. Minimum distance between a well and any on-site sewage disposal system is 100 fez for a private well or 150 to 200 feet from a public well depending upon the type of public well. Minimum distance from a private well to a private sewer line is 25 feet and to a community sewer line is 75 feet. Well logs are required and must be returned to this department within 30 days of the well completion. Other requirements may apply. Specifications and construction diagrams are available to insure proper installation. ' * ' PERMIT EXPIRES DECEMBER 31, 1 9 8 3 ' ' ' certify that:' (1) I am familiar with the requirements for on-site sewers set forth by the Municipality of Anchorage. (2) (3) Signe~: and wells as I will'install the system in accordance with codes. I understand that the on-site sewer system may require enlargement if the residence is remodeled to include more that 3 bedrooms. Applicant Date: SWP/024(1/S1) SOILS'LOG · MUNICIPALITY OF ANCHORAGE DEPARTMENT OF HEALTH AND ENVIRONMENTAL PROTECTION 825 L. Street. Anchorege, Alaska 99501 2644720 SOILS LOG - PERCOLATION TEST PERCOLATION TEST PERFORMED OR: · E~^L DESCmPT,ON: ~1~ 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16. 17- 18' 19. 20- COMMENTS PERFORMED BY: 72-008 (6/79) DATE PERFORMED: SLOPE SITE PLAN WASGROUNDWATER ENCOUNTERED? IF YES, AT WHAT ~ .. DEPTH? Gross Net Depth to Net Reading Date Time Time Water Drop PERCOLATION RATE .(minutes/inch) .,~ SOILS LOG MUNICIPALITY OF ANCHORAGE DEPARTMENT OF HEALTH AND ENVIRONMENTAL PROTECTION 82S L. Street, Anchorage, Alaska 99501 264-4720 SOILS LOG -- PERCOLATION TEST 1 9 10 11 SLOPE / PERCOLATION TEST SITE PLAN WASGROUNO WATE. ENCOUNTERED? DEPTH? P, cc. ~ I Gross Net Depth to Net Reading Date Time Time Water Drop · 20 - /~, Z PERCOLATION RATE '4"~L Iminutes/inch) =374 ~IIZ/:V~f~i 7_~" ~'~ ~J TEST RUN BE~EEN 7~ ET AND~ FT / . ,~/ .... ' PERFORMED BY: ~ CERTIFIED BY: /~ DATE: ~ ('./~,~ MUNICIPALITY OF ANCHORAGE DEPARTMENT OF HEALTH AND ENVIRONMENTAL PROTECTION 825 L Street. Anchorlge, Alaska 99501 264-4720 SOILS LOG -- PERCOLATION TEST [] SOILS LOGi~ 2/2. TEST DATE PERFORMED: LEGAL DESCRIPTION: 1 2 3 4 5 6 7 8 9 10 11 13- 14- 15- 16 17 18 19 20 COMMENTS SLOPE SITE PLAN WAS GROUND WATER ENCOUNTERED? IF YES. AT WHAT DEPTH? S Reading Date Time Time Water D,oP PERCOLATION RATE 30 ira;nut et/i~ch) , :~,, .2'-.,~" TEST RUN BETWEEN ~--~ , FT AND FT PERFORMED BY: CERTIFIED BY: ~..:. .. . . .' ~ '..' ! I :.'.: .. · ..... ':' '. ' '" I."t'.l ·" '< ' [] i ~ . . .: · · I~1 . ~ :' [ [ ;.,:.L..'.~.'.-'.'.. ' I,tl ~ ' ' ' · J/ /.--.'-/ , i./ , ' /I .- ' . . ~ceds ~ : ~ - ~... - .. ~ _...~ i · ~ ~ ' ../' . .. ,~1 / ~ ~'-- -~?t=~.- .-~ : . -. [ . b ./ ~,~ / : ~ V~h~ ~ I .-~ .~. / ' ~- ~:~;,, --. , . ~~-~"~- I ..... II ..- N · ~ ~ , ~ ~ · - ' - ~.~;;~ th . . .'_ / X= 7 ' :,-: :- - · ' ~ ~'~,~-rr'r~. -~_~ o~,._ (_1.~ ~. "' ~.~ ,~: ~~ ~ '~IJ::Z~'::' Fid~ I-~1'~" ~" . ~3": .... '~2';,~i~.: .. DEPT. OF ENVIRONMENTAL CONSER%~TION SOUTHCEHTRAL REGIOflAL OFFICE 437 "E" STREET, SUITE 200 ANCHORAGE, ALASKA 99501 dune 14, 1984 BILL .~HEFFIELD, C, Ot~TRNOR Telephone: (907] Addmss: 274-2533 MUNICIPALITY OF ANCHORA,~E D-rpT. OF HEALTH & £NVIRON,MENTAL P2OTECTICN I.Ir. Nell Hawthorne, P.E. 7127 Old Seward Highway Anchorage, Alaska 99502 RECEIVED Dear Nell: Subject: Lot 16, Block 3, Elmore Subdivision - Waiver Request A review of your request for a waiver to locate a septic tank 90 feet from the private well located at the above referenced site has been completed.. The waiver js hereby approved for the system as described- in your Hay 30, and dune II, 1984 letters. If you have any questions, do not hesitate to contact me. Bill Lamoreaux, .P.E. District Office Coordinator BHL/msm cc: Robbie Robinson (MOA) Municipa - of Anchorage POUCr'~650 ANCHORAGE, ALASKA 99502-0650 (907) 264-4431 TONY KNOWLE$. OFFICE OF THE MAYOR '~' Ms. Katherine M. Reed P.O. Box 110204 Anchorage, Alaska 99511 Dear Ms. Reed: I regret that your letters to the Department of Health regarding your case have not been answered in a more timely fashion. A letter response was, in fact, finished today. It was prepared by Ms. Susan Oswalt. You should receive it within one or two days. In your letters to the department you specifically requested that you not be contacted by phone. It has taken the Department of Health more than the normal length of time to compile and verify information pertaining to this case. Again, I apologize for the lack of a quicker reply. Sincerely, Tony Knowles Mayor POUCH 6-650 ANCHORAGE, ALASKA 99502-0650 (907) 264-4111 TONY KNOWLES. MA YOR DEPARTMENT OF HEALTH AND ENVIRONMENTAL PROTECTION July 24, 1984 Mrs. Katherine Reed Post Office Box 110204 Anchorage, Alaska 99511 Subject: Sewer System on Lot 16 Block 3 Elmore Subdivision The as-built drawing and report on your sewer system has been reviewed and accepted by the Municipality. 'This system is approved for a five(5) bedroom single family dwelling. Enclosed is a copy of the accepted as-built. If there are any further questions, please call this office at 264-4720. Sincerely, Susan E. Oswalt Engineering Tech III enclosure Al~ril 20, 19~4 Ms. Katherine M. Reed P. O. Box 110204 Anchorage, ?~ 99511 Subject: Set;ct Upgrade cn Lot 16, Block 3, Elraore Dubdivigion Dear I!s. Reed: I apologize for the delay in responding to your letters of inquiry about the stats= of your Gewsr system. This was due in part to ny attempt to gather all pertinent information on the case prior to response. Since you asked us not to telephone you I was unable to let you know. Enclosed you will find a copy of a letter addressing your ~ituation (dated February 29, 19S4). As you can gee there appears to be confusion about a waiver. Our records indicate no waiver was actually applied for or given. In fact, ~c would violate State law to give any distance waiver from 100 feet bet- ween the septic tank and the stream. According to ~ruce Erickson with the State Department of Environmental Conservation, he can- not legally waive that distance requirement under any circumstan- I have di~cusEed this ~ituation thoroughly with Dr. Leroy Reid, who believes it is I~ssible to r~ve the septic tank a minimum of 100 feet from thc creek. Therefore, we are requesting that the tank be m~ved within thirty (30) days. Your excavating company, Dearmoun Excavating, will be informed of thi~ order along wi~ your engineering firm. Please contact ~%e by ~one at 264-4720 if you have any further questions. Sincerely, Susan Ozwalt Eng. Tech. III EO/eJ/D15 cc: AECS - Reid ADEC - Erick~on RECEIPT FOR CERTIFIED MAIL--30~ (plus postage) SENT TO pOSTMARK OR DATE Katherin~ ~. l~',~,d ,' I STREET AND NO. .. , PO BOX 110204 P.O,,'STATE AND ZiP CODE Anchorage_, .. _A_l_aska 99511 4~23-84 OPTION&L S[KVICES FOR ADDITIONAl. dF~E$ PS Fo,. 3600 Apr. 1971 'l lO INSURANCE COV[RAGE PROVIDED-- NOT FOR INTERNATIONAL MAIL Mayor Tony Knowles Municipality of Anchorage 632 W 6th Avenue Anchorage, AK 99501 Dear Mayor Knowles: RECEIVED APR 1 0 '.,984 P. o. Box 110204 Anchorage, AK 99511 April 5, 1984 MAYOR'S OFFIC5 On March 4 we contacted by mail the Department APR 1 6 19 4 FROM MAYORS OFFICE of Health and Environmental Services regarding ap apparpnt lack of communication about our onsite septic system. For some reason, the inspectors will not certify that the system is acceptable, even though we seem to have ali the required permits and a bill that says the system was approved. We upgraded our system voluntarily and have paid nearly $8000 to have the work done. We asked the Health and Environmental Service office to contact us so that we could clear up the matter. When we heard nothing in two weeks, we sent another (certified) letter on March 21, which we know they received. Still no word from that office. We would like to resolve whatever'problem may exist. Somehow, a month's wait for a letter does not suggest that the deparmtent is a responsive agency of our city government. We hope you agree and would ask that they reply to our letters. Enclosed are copies of everything we have sent the Department to date. A copy of this letter is also being the deparmtent. sent to Thank you for your help. Sincerely, P.O. Box 110204 Anchorage, AK 99511 March.21, 1984 Municipality of Anchorage Department of Health and Environmental Services 825 L Street Anchorage, AK 99501 Sirs: On March 4 we wrote to your office concerning an apparent problem with approval of our upgraded on-site septic system. We enclosed copies of the Municipality's permit, the soils log, and the contractor's bill on which approval was indicated. We requested that you contact us by mail so that we could set up a meeting with your representatives to resolve any difficulties. We need to know the Municipality's position on this matter in . order to determine what further actions, if any, we should take. Again, we ask that you contact us by mail and let us know when you wish to meet with us. Sincerely, ~IOIL.~3J.O~J T~'J.N~HO~IA~q3 · ~ I.LLW;H JO '~I3Q Municipality of Anchorage Department of Health and Environmental Services 825 L Street Anchorage, AK 99501 P.O. Box 110204 Anchorage, AK 99511 March 4, 1984 Sirs: We were recently contacted by Jim Green of Akaska Environmental Control Services who told us that he could not approve our upgraded on-site septic system. We are surprised to hear there is a problem because we had the system upgraded in November and considerable time has passed without a word about difficulties. We live in the Elmore house is 20 years old. should we wish to sell septic system to meet prepared a soils test your office regarding subdivision, south of De Armoun road; the In early August of 1983 we decided that, the house, it would be wise to upgrade the codes. We contacted Nell Hawthorne, who report (enclosed) and spoke to Mr. Lynn of the position of the house and septic tank relative to Rabbit Creek and our plans to upgrade, tle mentioned these items because he believed a waiver could be obtained to allow us to upgrade without completely redoing the plumbing and installing complex pumping systems. When he spoke to us after talking to your office, he used words to the effect that there was no problem with the waiver. You will note that the copy of the basic plan we used (enclosed) makes note that a waiver may be required. We assumed that Mr. Hawthorne's eornuent meant that no further special efforts were needed regarding the waiver. Nevertheless, I made an appointment to meet with Mr. Lynn on ~August 31. I came to your office and talked for at least a half' ~'hour with Mr. Lynn, fully describing our situation and showing 'him the papers worked up by Mr.-tlawthorne. Mr. Lynn made no mention of a problem with the postion of the house or septic tank (as planned) relative to the creek; I made specific mention of the fact that the house had been built before codes in the area ~nd ht_b.~t ~ w~renlp_~Lng the ta_~nk forther from the cre_$_ek ad tha_.~t ~t._he n.~.ew l_each field w~uld--be more than'100'--i"eet-irrom the creek. 'We then worked ~-~ the lengt~ o'~'the"~lpe~"nee-'~ed ~Tth'~. ' ' Robinson, and a permit was issued (copy enclosed). ~Ther'e'is 'no' ~mention of"any irregularities or special situations on the ~permit. DeArmoun Excavating installed the new tank (larger than required) and also had the soil in the trenches inspected. The soil was considerably better than indicated in Mr. Hawthorne's test, and the trench length was recalculated. The trench was laid to avoid some large trees, and there is more than adequate slope for good drainage from the house to the tank to the trench. Mr. Caputo, of DeArmoun Excavating, made arrangements for the inspections, and the system was closed November 11. At no time did anyone indicate to us that the system was not entirely acceptable. We have paid Mr. Caputo; you will note that his bill (copy enclosed) notes that the upgraded system was "Inspected and approved by Ak Envir. Control Services". There is evidently some lack of con~unication or misunderstanding here. Would you be kind enough to review the documents enclosed, as well as your records of this permit, in the next few days? Representatives of your office are welcome visit the site. The outfall of the house plumbing is on the southwest corner of the house~ the snow may be too deep to see the stand pipes. Mr. Caputo or Mr. Hawthorne can show you the system should we not be available. to We have contacted all parties in this upgrading. As far as we know, everything to date has been done in good faith. We believe that our system should be approved as upgraded. Please contact us by mail so that we can arrange to meet with you and clear up this apparent problem. Sincerely, tlnlclp ,ll;y PO H6-650 ANCHORAGE, ALASKA 99502-0650 O~ 1907) 264-4111 Anchorage MA DEPARTMENT OF HEALTH AND ENVIRONMENTAL PROTECTION February 29, 1984 Dr. Leroy Reid, Jr. Alaska Environmental Control Services, 1200 W. 33rd Avenue, Suite B Anchorage, AK 99503 Inc. Res Lot 16, Block 3, Elmore Subdivision Dear Lee: A request was made by Mr. Neil Hawthorne last week to have this Department address a setback distance waiver between the septic tank and Rabbit Creek on Lot 16, Block 3, Elmore Subdivision. Referencing a copy of your company's as yet unapproved inspec- tion report/as-built, the current separation distance is 72 feet rather than the minimum 100 foot distance. During discussions with Mr. Jim Green of your company, it was discovered that, while serving as the onsite inspector, Mr. Green had in fact, requested DeArmoun Excavators to cease all excavation/installation activity upon his discovering the 72 foot setback distance. Apparently,' DeArmoun Excavators refused to cease all activity until resolution of the problem, stating to the effect that a waiver was already available. The septic tank was subsequedtly installed and it is assumed that backfilling occurred shortly thereafter. Although no onsite visit was made by this Department to date, both Mr. Hawthorne and Mr. Green have stated that ground slope between the septic tank and Rabbit Creek is significant and toward Rabbit Creek. Our Department has no record of having issued any waiver prior to this incident. Based on the above information and circumstan- ces, this Department is hereby refusing to issue a waiver from the normal 100 foot setback criteria, since we have absolutely no basis to date for allowing such a condition to exist. It is par- ticularly disturbing that the excavating company refused to acknowledge the wishes of the onsite inspector, who must assume responsibility for the excavator's actions when onsite. If you have any questions, please call this office at 264-4720. · Bandt, Manager Environmental Engineering Department of Health and Environmental Protection cc: Robert W. Robinson, Manager Environmental Health Division KB4/d5/s bPuwrs Mnnisipnlity nf An:eharng* On-$itE Sftt*r and Wastewater pr:sgr*ril tss?) 343"7$*4 Cettificate of Sn-$ite $ysterns Appr,au4{ Expir,ati*n sats: Jyl," I O hOnOTParc*l i. n.fi f,$-1 ?1 r5S "l Sf;SH*AL IF'FS&ffiATI*II{: Camplete legal de*cription Lccation {site addr*ss} turrent Fruperty owneris) Mailing ad$ress Rsal Fsfflt* A$enl iAuanue'A Day pfion:e $sichgl[f;:Ne]*s** ., ,, , .,,. ,." .,. ,.,,, * Dey prione .fi$s-*S7*.'- ?YFE SF NIJiIEI-IIFTG: ffi Singl* Family {wlrva ADU) il Duplex il Multiple Dwellings {$:ingl* Family andlor.Duplex} MUHSEft fiF BHNRCISilII$: 4 YVpfr 'Slr ISfATER $:UFFLY: lndirridusl Wsll I ndividu*l \&later $t*rage Somrnunify f;lars_Well Publie Wat*r $yslen"l Walvgr"Ilcria,nc* raquxsl fsrj.."-. . , TYPF SF WAS?gIfr'ATg* H$TS$*L: lndividual " ffi Halding Tank 1 t ffa*rmunity : n Pubtic $ewe,r I tl ? 4. lffit"A"t il r-1 L-J u Di*tar'lge: Re**ived by: ctlsF' l$ b€ rfl$s$ed t€ tfiE snginF€r. unts$s Dihef$ri$e fequ*s$d br th* *n$nffif. Sate: CS$A f*u t.---.. ..-, ,,,.Weirr,rer FEe 9 sar* *r F*yme nt ,, . - ,.Hf8leq,,? ,,:,, ,,,,,,, . Re$eipt Nurnber ,. , ,.,.,, ftl q ,?eq so$A # ., .fiAT*{1"ttqA , Date of Paymerrt Reqsipt'${unrb'er Wsiver# 5. sTATEMT,.\$I" SF Iru$PESTI*F{ tsY EruG'ruEFR As certified by my seal affixed hereto and as of the validation date shor,vn below, I verify that my investigation, based on procedures outlinerl in the Certificate of On-Site Systems Approvat Guidelines for this appliiation, shotr,'s that the on-site water supply andlor wastevrraier disposal system is (are) safe, functional and adequate for the number of bedrooms and type of struciure indicated herein, I further verify that based on the information obtained from the Municipality of Anchorage files and from my inrrestigation and inspection, the on-site water supply and/or wastewater disposal system is(are) in compliance witir all applicable l\lunicipal and $tate codes, ordinances, and regulations in effect at the iime of installation. Name of Firm. Garness Enqineerinq Groun, Ltd {G[G)P h o n e : 907-33-----------------7:6 1 7 I Address: $01 East Tudor Road. Suite 101- Anchoraqe, Alaska 9950i Engirreer's Prinled Name: Jeffrev A. Garness ln conduciing this evaluation, GEG provided an engineering evaluation of the welf andior septicsystem in accordance wiih the guidelines arrd regulations established by the fulunicipalrty of Anchorage and inciustry practices The reporied results describe the concjition of the system/s on the date/s oi ihe evaluatton Separation distances were measured to readily identifiable features, Hidden defects or encroachments may exist that uvere not identified cluring lhe evaluation. The cperational life of all rvells and septic systems depend upon a variety of variables, including but not limited to, soil conditions, f;: , - groundwater levels (that may fluctuate during the year), quaiity of construction (maieriats and , ,:;, it "'.-' workrnanship), and the r,vater usage oi the family utilizing the system/s, Tlrese conditions can vary, anO [ .r;'"-" are outside the control of GEG. Satisfactory test results do not guaraniee future performance of tne \1; systemls; therefore, GEG makes no $/aranly (express or implied) regarding the future performance of .},l;l.-r4l thewell or seplic sysien. GEG makes ro epresenlalion whelher an alternatile well oi seDtic svstem ,', - .l.lt"ltr F ',:":|-.: .'; can be hslalied on the propeny in lhe event erthor of the crj(ent systems fait to pedom adisquaiety in t:..'" Jl {;-\t.i J.- ,.7 rhe future. The conrenl or lhis 'eport ts for the sole benefr ot th; person/pa(y lhat ,era;nj eed ro , 1 . fl ._, L Y :t?pe.iorm the evaluation. Reliance upon the rntomation provided in ihis 'epbn 6y any other person o, t.d ,ft#(La.;,17party (incluoing eubseoJent property purchasers) is not aLlhorized nor wi it coafer any legat rjghr a li;i*aaitjwhatsoever' #AECcgg46. DSD SIGNATURE ,I'/ ll::ilffil;::::-z-::Hil: ....rq$\'6r'q2,Disapprovect _i; * oN-slrE "Z&^ Conditional approval for bedrooms, with the fottowing sti$S"WXiit'nin Wz :v'TATER ==;;;-;; -vlFROGhAM €'S,S-s.\$s K'o" ItDate. Yi +rf uc - By:Original Certificate Daie: The Municipality of Anchorage Oevefopntent Services Division (DSD) issues Certificates of On-Site Systems Appro,ral (COSA) based onlyupon the represeniations given in paragraph 5 by an independeni professionalcivilengineer registered inthe state of Alaska. The Municipalityof Anchorage is not responsible for errors or omissions in the professional engineer's rr]ork. 7. ATT&Ct-tffiE$CT$: COSA Checklist Septic System Advisory Well Flow Advisory Nitrate Advisory Arsenic Advisorlr Other COSA Checklist Legal Description: ELMORE #1; BLOCK 3, LOT 16 C� If more than 1 septic system on lot: COSA Checklist # 1 of J vim �d�Gc��Z Parcel ID: 018-171-50 Structure served by this system 1 a A. WELL DATA 1-71 I- ❑ Well log is filed with Onsite (or attached) Well production at time of test 3 9+ gpm Date drilled 1963 �'� Water storage tank volume N/'°` gallons Total depth *46.1 ft Well disinfected for coliform test? ❑ Yes X No \ UNKNOWN N Cased to ft ❑E Coliform bacteria is Negative 3.78 ❑■ Sanitary seal is functioning correctly Nitrate mg/L ❑ Nitrate less than MRL (ND) ■❑ Wires are properly protected Arsenic ug/L ❑■ Arsenic less than MRL (ND) w�--- Casing height (above ground) ** in. Collected by GEG, LTD. Date of flow test for COSA 2/4/20 Date of Sample 2/5/20 Static water level at beginning of test 39.9 ft. Comments *PER GEG WELL FLOW TEST **SEE PHOTO SHOWING SUMP NEXT TO WELL - SEE EMAIL FROM DAVE HARPER SEE ATTACHED EMAIL BETWEEN ARM SEPTIC SERVICES, GEG AND MOA B. TANK DATA REGARDING ELECTRICAL LINE FROM SEPTIC TANK TO HOUSE I C. LIFT STATION Age of tank(s) NEW years Tank type/material SEIH IE Measured operating fluid level in septic tank N/A ❑■ Standpipes/foundation cleanout per record drawing Date of pumping NEW D. ABSORPTION FIELD DATA DUAL TRENCH ❑ Required maintenance completed Age of lift station - years Lift station material - Comments: HIGH WATER ALARM INSTALLED ON SEPTIC TANK AS REQUIRED BY MOA FOR SURFACE WATER WAIVER Which system tested (date installed) 7/6/84 Adequacy test date 2/4/20 ❑■ ALL standpipes present per record drawing Results IDPass For 4 bedrooms Total measured depth from grade 4.3 ft (max) Fluid depth prior to test 0 in Measured depth to pipe invert from grade 2.75 ft (min) Water added 786 gal ❑ N/A — pressurized field 7 New depth in ❑ Monitor tubes go to bottom of effective. If not, state 120 depth into effective "'1"&20' Elapsed time min P FE -1 Code -required soil cover over field Final fluid depth 2 in ❑ System presoaked Absorption rate 600+ gpd (Required if vacant for greater than 30 days prior to Any rejuvenation treatment (past 12 months) NONE date of test) Gallons introduced N/A gallons If yes, enter date N/A Comments/Deficiencies: TESTED WEST TRENCH ONLY- DRAINFIELD INSULATED PER MOA RECORDS "SUMP ONLY EXTENDS 19 & 20 INCHES BELOW INVERT AT TIME OF TEST LIQUID LEVEL IN THE EAST TRENCH WAS AT 9 INCHES ON THE DATE OF THE TEST COSA Checklist yellow sheet E. SEPARATION DISTANCES From Private Well on Lot to: (Please enter distances if less than required or if community well) Septic Tank/Lift Station on Lot > 100'**90 ❑✓ Yes 1 Community Sewer Manhole/Cleanout > 100' If absorption field is under driveway comment below Property Line > 10' ❑ Yes if No ft ❑✓ Yes if No ft Neighboring Tank > 100' ❑✓ Yes if No ft Private Sewer/Septic Line > 25' ❑✓ Yes if No ft Absorption Field on Lot > 100' ❑✓ Yes if No ft Holding Tank > 100' ❑✓ Yes if No ft Neighboring Absorption Fields > 100' Animal Containment > 50' ❑✓ Yes if No ft ❑✓ Yes if No ft Manure/Animal Excreta Storage > 100' Community Sewer Main > 75' ❑✓ Yes if No ft ❑✓ Yes if No ft From Septic/Holding Tank on Lot to: (Please enter distances if less than required) Building Foundations > 10' ❑✓ Yes if No ft Surface Water> 100' El Yes if No **60 Property Line > 5' ❑✓ Yes if No ft Wells on Adjacent Lots: Absorption Field > 5' ❑✓ Yes if No ft Private Wells > 100' ❑✓ Yes if No ft Water Main > 10' ✓❑ Yes if No ft Community Wells > 200'✓❑ Yes if No ft Water Service Line > 10' ❑✓ Yes if No ft If septic tank is under driveway comment below From Absorption Field on Lot to: (Please enter distances if less than required) Building Foundation > 10' ❑✓ Yes if No ft If absorption field is under driveway comment below Property Line > 10' ❑ Yes if No *0 ft Wells on Adjacent Lots: Water Main > 10'✓❑ Yes if No ft *** Private Wells > 100' ❑✓ Yes if No ft Water Service Line > 10' ❑✓ Yes if No ft Community Wells > 200' ❑✓ Yes if No ft Surface Water > 100' ❑Yes if No **60 ft F. ENGINEER'S COMMENTS *LETTER OF NON -OBJECTION PENDING **WR#OSV201011 ***WELL ON ELMORE #1; BLOCK 5, LOT 2 COULD NOT BE FOUND - THEREFORE SEPERATION DISTANCE COULD NOT BE VERIFIED G. ENGINEER'S CERTIFICATION I certify that 1 have determined through field inspections and review of Municipal records that the above systems are in conformance with MOA COSA guidelines in effect on this date. COSA Checklist yellow sheet 0o O F A v��4 ........... . .... ........... f J .. .. . '.............. ff y rness.- E—.795 SSS 0fess10n o o #AECC884 David Garness From: Andrews, Toms <Toms4n ews@oilseaoh,com» 4— &—� ^� \5 Sent: Thursday, Aph!�2O2O5:5OP� > ~^ To: DavdGames'`"~��- Subject: shoshoni house sale David As per our conversation; I am fine with ARM Septic service coming back in the spring to finalize the electrical work for the septic tank. | would also like bnadd that 43GUShoahonidoes not have a water storage located onthe premise. Thanks for your help here David. Thanks Toms Clinton Toms Andrews. TOMS ANWEmS LOG71STI IC C(DORDINATOR I OIL SEARCH LIMITED Aurmhotel/oeadhorse Mobile 907-346-0051 Office 907-685-4201 Home 907-244-9677 ****~********This e-mail may beconfidential and/or privileged, Only the intended recipient may access mruse it. |f you are not the intended recipient, please notify us promptly and delete this e-mail and its attachments from your system. The views expressed by the sender are not necessarily those of Oil Search Limited unless otherwise specifically stated. We use virus scanning software but exclude all liability for viruses or similar in any attachment. Think of our environment before you print this e-mail ************* David Garness From: ARM Septic Services, LL[«annservkesak@outlookcom> Sent: Friday, April J.2O2010:08Ak4 To: David Garness Subject: 4360 Shoshoni - Tank completion Hello David, The installation has been completed at Shoshoni. The tank was perminantly equipped with a Anchorage tank float tree and high water alarm kit. Additionally, we perminantly installed an indoor alarm inside the residence with a remote monitoring device. This spring we will simply quickly trench between the tank and house to connect a low voltage wire in conduit between the two together. ARM accepts responsibility to ensure this is completed in a timely manor. Respectfully, Rob Campbell Managing Member ARM Septic Services, LLC Ph: (907) 098'8433 Cell: (907) 317f9433 Email: ARMServIcesAKk@outIook.corn VVebsite:vxw�.ARK48emicee4Konm Fanobook:wvmw.fanebook.com6ARK8SenioeoAK/ _ � b oil Z � I - ems- .� � , wi► . . ,,N111111111\1 Q , +. t�W . 94. Jeff Garness From: David Harper <dlharper2@gmail.com> Sent: Saturday, February 8, 2020 8:14 PM To: Michelle Nelson; Jeff Garness Subject: 4600 Shoshoni Avenue Jeff, Michelle, the wiring on the above well site would be the same as in a crawl space so should be passing with MOA. The well cap has been sealed so no foreign material can enter. We found a leak in the water system which has been causing extreme rusting of both the exterior of the well casing and pressure tank. This has been fixed. We also found there was very little air in the pressure tank. We added air to 38 psi and the system is working fine at this point. The diaphragm in the tank appears to be damaged. The tank will need to be replaced in the near future or keep adding air occasionally to prevent the pump from cycling to much. The well casing is below grade, however it is located within the house in an off space from the lower level. There is a sump pump 3 feet from the well which would negate water entering or pooling around the well. If you have questions, please let me know. David Harper Aarow Pump & Well Service, LLC r