HomeMy WebLinkAboutELMORE #1 BLK 6 LT 5
' '~ MUNICIPALITY OF ANCHORAGE
DEPARTMENT OF HEALTH & ENVIRONMENTAL PROTECTION
ENVIRONMENTAL ENGINEERING DIVISION
' 825 L Street- Anchorage, Alaska 99501 Telephone 264-4720
~)N-SITE SEWAGE DISPOSAL SYSTEM AND/OR WELL INSPECTION REPORT
NAME ~ PHONE F-} NEW
Inside length W~dth Liquid depth
[~ ~ IF HOME.DE:
Well Dwelling PERMIT NO.
No. of lin~ Total leng h of lines Trane idlh
O Total ef f~ti~ absorption area
< ~ Type of crib Crib diameter Crib depth
~ Well Building foundation Nearest lot line
~ DISTANCE TO:
~ Building foundation Se~r line Septic tank Absorption area(si
~ DISTANCE TO:
OTHER
72-0' IRev. 3/78) ~ ~
· ~"DE~ARTMENT OF HEALTH AND ENVIRONMENTAL PROTECTION
" -~ ~'~ ' 825 'L' S~REST, ANCHORAGE, AK. 9~5~1
PERMIT NO. ( 780~5~ )
'APPLICANT L~RRY KANUIT
,LOCATION NATRONA ST
:LEGAL ' L5 BG ELMORE
TYPE Of SOIL ABSORBTION SYSTEM IS:
SPA BOX ~3~
LOT SIZE
344
30000 SQUARE FEET
iMAXIMUM NUMBER OF BEDROOMS = 4 SOIL RATING (SQ FT/bR)= 0
~:THE REQUIRED SIZE OF THE SOIL ABSORPTION SYSTEM
DEPTH= 0 LENGTH= 3:L GRRVEL DEPTH=
THE LENGTH DIMENSION IS THE LENGTH ¢IN FEET) OF THE TRENCH OR DRAINFIELD.
THE DEPTH OF A TRENCH OR PIT IS THE DISTANCE BETWEEN THE SURFACE Of THE
GROUND AND THE BOTTOM OF THE EXCAVATION (IN FEET).
THE TRENCH W I DTH I S
THE GRAVEL DEPTH IS THE MINIMUM DEPTH OF GRAVEL BETWEEN THE OUTFRLL PIPE
AND THE BOTTOM Of THE EXCAVATION (IN FEET).
REQU I RED SEPT I C TANK ~ I ZE= $00 G~LLO~S
~,PERMIT APPLICANT HAS THE RESPONSIBILITY TO INFORM THIS DEPARTMENT DURING THE
i INSTALLATION INSPECTIONS OF ANY WELLS ~DJACENT TO THIS PROPERTY AND THE
!NUMBER OF RESIDENCES THAT THE WELL WILL SERVE.
', TWO (2) INSPECT I O~S ARE REQU I RED -----
,BACKFILLING OF ANY SYSTEM WITHOUT FINAL INSPECTION AND APPROVAL BY THIS
!DEPARTMENT WILL BE SUBJECT TO PROSECUTION.
~MINIMUM DISTANCE BETWEEN R WELL AND ANY ON-SITE SEWAGE DISPOSAL SYSTEM IS
100 FEET FOR R PRIVATE WELU OR
~150 TO 200 PEET FROM R PUBLIC WELL DEPENDING UPON THE TYPE OF PUBLIC WELL.
OTHER REQUIREMENTS MAY APPLY. SPECIFICATIONS AND CONSTRUCTION DIAGRAMS PRE
AVAILABLE TO INSURE PROPER INSTALLATION.
PERM I t EXP I RES DECEMBER
I CERTIFY THAT
l: I RM FAMILIAR WITH THE REQUIREMENTS FOR ON-SITE SEWERS AND WELLS RS SET
FORTH BY THE MUNICIPALITY Of ANCHORAGE.
'2: I WILL INSTALL THE SYSTEM IN ACCORDANCE WITH THE CODES.
~: I UNDERSTAND THAT THE ON-SITE SEWER SYSTEM MAY REQUIRE ENLARGEMENT IF THE
RESIDENCE IS
REMODELED TO INCLUDE MORE THAN 4 BEDROOMS.
~PPLI CANT/? LFlRRV KRNUIT
,4___% P
HEALTH DEPARTMENT ' ' 1~0,
327 EAGLE ST. ANCHORAGE, ALASKA 99501 279-2';11
INSPECTION REPORT ON-SITE SEWAGE DISPOSAL SYSTEM
165
LOCATION
SEPTIC TANK:
DISTANCE FROM WELl
LIQUID CAPACITY ~'-~
GALLONS.
MATERIAL ~"?~°~'~'~--'~/~'~'~-'~-~ NUMBER OF
COMPARTMENTS
INSIDE LENGTH ~ INSIDE WIDTH ~
LIQUID ~ /
DEPTH
SEEPAGE SYSTEM: SEEPAGE PIT:
NUMBER OF PITS // OUTSIDE DIAMETER
LINING MATERIAl
NEAREST LOT LINE
OR WIDTH_
· DISTANCE FROM WELl /~'~ /
~-.-~"~ / TOTAL EFFECTIVE ABSORPTION AREA (WALL AREA)
LENGTH //~'/ '~
, , DEPTH
BUILDING FOUNDATIOI~
so.
TILE DRAIN FIELD:~ ~ .
DISTANCE FROM WELl ~' , FOUNDATION , NEAREST L~'~INF OF [~NES
DEPTH: TOP OF TILE TO FINISH GRADE DEPTH OF FILTER NLATERIAL BENEATH TILE .IN. ABOVE TILE
WELL: h, p F ,.~-~/,~/,.,,,~._.,,....~ ~ DEPTH ~',/ · DISTANCE FROM · WATER
,BUILDING FOUNDATION. /'"'~'~'"" /f~? , NEAREST
. SAMPLE
LOT LINE ,,,/~.) /~., NEAREST ~ SEPTIC .~ SEEPAGE / //OTHER
SEWER LINE lANK ~'/ . SYSTEM /~/~ . CESSPOOl -- , SOURCES
DISTANCES:
DIAGRAM OF SYSTEM
o,~....~ GREATE.'-~,&NCHOR,AGE AREAf"~ROUGH c~eHo. ~'.~/
'; 327 Eagle St. Anchorage, Alad~a 99501 279-2511
~EW~GE DISPOSAL SYSTEM - APPLICATION & PERMIT ~,~,
.~ o~ ~,~.~/~ ~z~ ~ ~,~,~ ~~ ~ a a.~&~o.?~.~ ~Y
RESIDENCE ADDRESS 7~/~-- ~ ~Z LOCATION OF INSTAL~TION~P~/~/ ~
' ~E~*L ~scmpT,o. ~~ ~ ~ ~~ ~
, OTHER
APPLICATION TO INSTALL: SEPTIC TANK ~, SEEPAGE PIT ~ , DRAIN FIELD
TO SERVE THE FOLLOWING FACILITY ~
FINANCED THROUGH TO BE INSTALLED BY~_.~~
TEST RESULTS
ANTICIPATED DATE OF COMPLETION
BELOW TO BE Flttl:n OUT BY HEALTH DEPARTMENT
HEALTH AUTHORITY
I certify that I am familiar with the requirements of Greater Anchorage Area Boroug~2rdinance No. 28-68 and ~hat the
above described system is in accordance with said code.
-/ /
C'REATER ANCHORAGE AREA BORO~GH
HEALTH DEPARTMENT
327 EAGLE STREET
ANCHORAGE, ALASKA 99501
Performed For -Larry Kaniut Date Perfor~ned
LeKal Descplption: Lot 5 Block 6 SubdivisiOn. ,,Elm°re ,.MI
.-~ercolatlon
This Fc~m Reports a:
Depth
Feet Soil CharacterisTics
silty fine sand
.(SM)
2 brown & gray gravelly
fine to coarse sand
3 (SW)~
4
Was Ground Water Encountered?
If Yes, At What Depth
no
Reading Date Gross T/me Net Tlme Depth To H20
CASE #
7/~4/70
Lo,at'on Sketch
Net
Proposed In~tal~Seepage Pit Drain Field
Depth Of Inlet Depth To Bottom Of Pit Or Trench
COMMENT$:..necessary drainage surface grea iF 125, s~ua[e feet per be~'r~Jm
Test Performed
Data Certified By:., Ngtional Testin~ Se~vices, Inc.
Date:
MUNICIPAUTY OF ANCHORAGE ~ ..... ... ,, '-.': ;~
DEPARTMENT OF H~LTH & E~IRONME~AL PROTEC~ON
ENVIRONMENTAL ENGINEERING DIVISION ~.., ~ .... . . . .
REOUE~ FOR ~PROVAL OF INDIVIDUAL WATER ~D SEWER FACILITIES
)lRECTION~:.Complete all par~ on page 1. I~lml ~ will ,m be i~mmlld. Ptl~e allow ten (10) days for proctoring.
1. PROPERTY OWNER
MAILING ADOREe~e
SPA l~ox 333. Anchn'ra~e. Alaska.
PROPERTY ~ESIDENT (If diff~t fr~ ~) '
99507
PHONE
344-s63o
PHONE
PHONE
2. BUYER
S~me as above
MAILING ADORESS
·--LENDING INSTITUTION
~ILING ADOR~
310 E, Northe~ Lights, ~chorage, Alaska
99503
PHONE
279-7637
PHONE
MAltING ADORE~
~. LEGAL DESCRIPTION
Lot 5, Blk 6, glmore S/D ~1
STREET LOCATION
NHN NaCrona
6. TYPE OF RESIDENCE
~ SINGLE FAMILY
[] MULTIPLE FAMILY
NUMBER OF BEOROOM~
r-I One [~ Four
[] Two [] Five
[] Three [] Six
[] Other
7. WATER EUPPLY
INDiViDUAL'
[] COMMUNITY
[] PUBLIC UTILITY
I[ SEWAGE DISPOSAL SY~'rEM
[]~3 INDIVIDUAL/ON-SITE"
[] PUBLIC UTILITY
* ATTACH WELL LOG. A wall log is required for all walls drilled
since June 1975. For walls drilled prior to that date, give wall
depth (attach log if available.)
If md,v,dual/on-site, give installation date
If system is over two (2) years old an adequacy test is required
by this Department.
NOTE: THE INSPECTION FEE MUST ACCOMPANY EACH REQUEST BEFORE PROCF. S~ING CAN BE INITIATED.
72.010t3118}
. __.,.' THIS SIDE FOR OFFICIAL USE ONLY ~,~
DATE RECEIVED
iNSPECTION APPOINTMENTS
TIME TIME TIME
DATE DATE DATE
INSPF'C¥~R INSPECTOR INSPECTOR
DIRECTIONS:
1. TYPE OF RESIDENCE NUMBER OF BEDROOMS
r-q SINGLE FAMILY I--1 ONE [] THREE [] FIVE [] OTHER
I--I MULTIPLE FAMILY [] TWO [] FOUR [] SiX
2. WATER SUPPLY PERMIT NUMBER
[] INDIVIDUAL DEPTH OF WELL
[] COMMUNITY
DATE DRILLED
[] PUBLIC UTILITY
Connection Verified LOG RECEIVED
3. SEWAGE DISPOSAL SYSTEM PERMIT NUMBER
[]INDIVIDUAL/ON -SITE DATE INSTALLEQ
[]PUBLIC UTILITY~_"~ ~
Connection Verified
INSTALLER
r--ISeptic TAnk or []HoldingTank
Size: '~/ If Tank is homemade SOILS RATING
give dimensions:
TYPE OF TANK MANUFACT~,~ ~
TOTAL ABSORPTION AR EA MATER,AL
-- {/ I
(~L~ROVED FOR ~BEDROOMS
;--I CONDITIONAL APPROVAL (letter must accompany certificate)
[]~,~/DISAPPROVED (~/~
DATE BY
LEGAL DESCRIPTION ~,
72-010 (Rev. 3/78)
Larry Kanuit
SRABox 333
Anchorage, Alaska
RECEI.V. ED.
Re: Adequacy Test on Existing Sanitary Sewer System; Lot 5, Block 6, Elmore
Subdivision, Anchorage, Alaska
Dear Mr. Kanuit:
Per your request of September 13, 1978, we conducted a. test of the sanitary
sewer system on the above described property.
Five hundred gallons were pumped from the septic tank' prior to the
performance of the test on the seepage pit. During the test the liquid level
in the seepage pit was monitored as 750 gallons were removed and 800 gallons
were pumped back into the seepage pit to the inlbt level. Ail liquid levels
were measured below the top of the standpipe and are shown in the following
table:
Initial Liquid Second Water Third 24 hour Total
Reading Removed Reading Added Reading Reading Drop
(gallons) (gallons)
5.75' 750 8.70' 800 5.25' 6.30' 1.05'
The average specific capacity is 20.3 gallons per inch based on two sets of
readings showing 21.1 and 19.3 gallons per inch. After twenty four hours the
liquid level was measured again at 6.30 feet. It had dropped 1.05 feet or
12.6 inches. This indicates an average effluent acceptance rate of 255.8
gallons per day for the surrounding soils. If the 4 bedroom residence on the
property is to house 8 people, the average load on the system can be expected
to be 600 gallons per day. We can therefore conclude that the system is not
disposing of effluent at an adequate rate for a 4 bedroom residence.
September 15, 1978
Larry Kanuit
Page -2-
We appreciate this opportunity to be of service to you. Please contact us if
you have any questions regarding this letter or if we can be of additional
service to you.
Very truly yours,
Rf~M ~ONSULTANTS, I~NC.
GS/djb/12-F
September 2~, 1970
Larry Lo Kanuit
'Star Route A ~ox 333
Anchorage, Alaska 99507
subJectt Lot 5 Block 6 Elmore Subdivision
Before this departm, ent m~y approve the re~lost for
sewer and water approval, an upgrade of the sewer
system wtll bc required.
(1) Add on an additional 50~ gallon septic t~nk
to the ~isting 720 gallon tank.
(2) Using tho existing seepage pit, from the top
of tho crib come out with a ten(lO) foot solid
pipe, which shield be camt iron or its equivalent.
Your trench should start at that point. The trench
ohould be thirty-one(31) feet in length with
foot of gravel below tho drain pipe.
f
Prior to the upgrade, a per=it nu~t be issued by this
If there are any further questions, please contact
this office at 264-4270.
S~ncerely~ ~ · '
Robert C. Pratt,
Associate
Rc~/I~ ,.-
Cc~ Alaska Statebank %
310 East ~orthern L~ght~ Boulevard
99503