HomeMy WebLinkAboutELMORE #2 BLK 11 LT 5more
MUNICIPALITY OF ANCHORAGE
On -Site Water & Wastewater Program
PO Box 196650 4700 Elmore Road
Anchorage, Alaska 99519-6650 Phone: (907) 343-7904 Fax: (907) 343-7997
http://www.muni.org/onsite
On -Site Water & Wastewater System Permit
Permit Number: OSP201241
Work Type: WellSeptic Initial
Tax Code Number: 01817329000
Site Legal Address: ELMORE #2 BLK 11 LT 5 G:3036
Site Mailing Address: 4500 E 147TH AVE, Anchorage
Owner: PETRUSKA BARBARA RUTH
Design Engineer: FORGE ENGINEERING
This permit is for the construction of:
Q Disposal Field 21 Septic Tank ❑ Holding Tank ❑ Privy
Effective Date:
Expiration Date:
mcnr
�` s�^
c.part❑netlt
Lot Size in Sq Ft:
Total Bedrooms:
7/28/2020
7/28/2021
74727
4
2 Private Well ❑ Water Storage
All construction shall be in accordance with:
1. The attached approved design.
2. All requirements specified in Anchorage Municipal code Chapters 15.55 and 15.65 and the State of Alaska
Wastewater Disposal Regulations (18AAC72) and Drinking Water Regulations (18AAC80)
3. The wastewater code requires inspections during the installation. The engineer shall notify the Development
Services Department per AMC 15.65. Provide notification by calling (907) 343-7904 (24/7).
4. From October 15 to April 15, a subsurface soil absorption system under construction during freezing weather
shall be either:
a. Opened and Closed on the same day, or
b. Covered, sealed, and heated to prevent freezing
Special Provisions: Prior to construction, TH2 is to be.deepened to 12' to verify the lack of impermeable soils.
1 Soils log to be submitted with the Inspection Report.
Received B�
Issued By:
Date: 2— L
Date: A91 ZZ—!C)
UNICPALITY OF ANCHORAGE
Community Development Department Phone: 907-343-7904
Development Services Division Fax: 907-343-7997
On -Site Water & Wastewater Program
ON-SITE SEWER/WELL PERMIT APPLICATION
Parcel I.D. 018-173-29
Property owner(s) Barbara Petruska Day phone 350-2419
Mailing address 4 Marble Beach Lane N.W. Gig Harbor, WA 98332
Site address 4500 E. 147th Avenue Anchorage, AK
Legal description (Sub'd., Block & Lot) Elmore #2, Block 11, Lot
Legal description (Township, Range & Section)
Lot Size 74,727 Sq. Ft. Number of Bedrooms Four (4)
APPLICATION IS FOR:
APPLICATION IS AN:
TYPE OF DWELLING:
(® all that apply)
Absorption Field
❑X
Initial ❑X
Single Family (SF)
❑X
AD U)
Septic Tank
❑X
Upgrade El(w/wo
Duplex
ElHolding
(D)
Tank
❑
Renewal ElMultiple
Dwellings
❑
Privy
❑
(SF and/or D)
Private Well
❑X
Water Storage
❑
THIS APPLICATION INCLUDES A VARIANCE / WAIVER REQUEST FOR:
Distance:
I certify that the above information is correct. I further certify that this is in accordance with
applicable Municipal Codes.
(Signature of property owner or authorized agent)
Permit/Rush Fees:k [ 5 I Cov 16
Date of Payment:
Receipt Number: 06 1-177D
Permit No. 05P 20 j 24 1
Permit App_'-'- : :'_.,:c
Waiver Fees:
Date of Payment:
Receipt Number:
Waiver No.
PO BOX 240773
ANCHORAGE, AK 99524
522-7773 677-7766 (FAX)
July 15, 2020
MOA Development Services Department
On-Site Water & Wastewater Program
4700 Elmore Road
Anchorage, AK 99507
Subject: Elmore #2, Block 11, Lot 5 – 4500 E. 147th Avenue
Septic System Design
Dear On-Site Services Engineer:
The owner of the subject lot intends to construct a four-bedroom home on the property. We are
submitting this permit application for the construction of a new well and septic system to serve the
home. The attached site plan identifies the location of the home and the proposed well and septic
system.
No conflicts exist between this proposed well and septic system and any other well or septic system
on adjacent lots. The ground surface on the lot is virtually flat in the area of the new trench but
slopes to the west at shallow grades. Surface contour lines are shown indicating direction of flow.
Storm water flow will not impact the proposed septic system.
Wells on this and adjacent lots are shown. The new septic system will be a minimum of 100’ from
the well on this lot and 100’ from all wells on adjacent lots and any surface water. The tank will
be 10’ from the house foundation and 5’ from deck and stair supports.
Please refer to the attached plan sheet for the septic design. If this design is followed, there will be
no adverse impacts to adjacent properties.
Sincerely,
Michael E. Anderson, P.E
7/15/20
Municipality of Anchorage
On-site Water and Wastewater
REVIEWED FOR CODE COMPLIANCE
OSP201241, Deb Wockenfuss, 07/29/20
ALTERNATE SITE
10050 0
FEET
1"=100'
2-60' LONG x 5' WIDE x .5'
EFFECTIVE DEPTH
ABSORPTION TRENCHES
4-BDRM HOME
1,250-GALLON
SEPTIC TANK W/
20" MANWAY
NOTE:
NO SLOPES >25% WITHIN 50' OR SURFACE WATER WITHIN 100' OF THE
PROPOSED SEPTIC SYSTEM
ALL WELLS ON SURROUNDING LOTS WITH IMPACTS TO THIS
PROPERTY ARE SHOWN. NO CONFLICTS WITH WELLS OR SEPTIC
SYSTEMS.
CO - CLEANOUT
2CO - DOUBLE CLEANOUT
FCO - FOUNDATION CLEANOUT
FS - FLOW SPLITTER VALVE
MH - MANHOLE
MT - MONITORING TUBE
SV - SEPTIC VENT
TH - TEST HOLE
LEGEND
MH
ELMORE #2, BLOCK 11, LOT 5
TETON PLACE7/24/20
10' UTILITY EASEMENT
TH2
TH1
SV
2CO FS CO
MTCO
CO
CO
MT
PROPOSED WELL360 365NOTE:
DEEPEN TH2 TO A MINIMUM OF 12'
PRIOR TO CONSTRUCTION TO VERIFY
LACK OF IMPERMEABLE SOIL LAYERS.
NO EXISTING WELL WAS FOUND ON LOT.
OLD SEPTIC SYSTEM.
DECOMMISSION PER U.P.C.
Municipality of Anchorage
On-site Water and Wastewater
REVIEWED FOR CODE COMPLIANCE
OSP201241, Deb Wockenfuss, 07/29/20
ELMORE #2, BLOCK 11, LOT 5
DESIGN FACTORS: SYSTEM REQUIREMENTS:
600 GPD PEAK FLOW
PERK RATE: <1 MIN/IN
APPLICATION RATE: 1.0 GPD/SF
5' WIDE TRENCH SYSTEM
1,250-GALLON SEPTIC TANK
2' MOA APPROVED SAND LINER
TYPICAL TRENCH SECTION
(NO SCALE)
NOTES:
1. GRADE AREA OVER TRENCH TO DRAIN AWAY
2. PROVIDE 3' OF COVER OVER TRENCHES AND 4' OVER SEPTIC TANK, OR 2'
WITH 2" OF INSULATION
3. CHECK GROUNDWATER AT TIME OF CONSTRUCTION. IF LEVEL IS HIGHER
THAN PREVIOUSLY OBSERVED, CALL ENGINEER IMMEDIATELY
BOTTOM OF TRENCH: 5.0' BELOW GRADE
FLOW LINE ELEVATION: 4.5' BELOW GRADE
TOP OF TRENCH: 0.5' ABOVE GRADE
600 GPD / 1.0 GPD/SF /5' WIDE * 1.0 (RED. FACTOR) = 120 LF TRENCH REQUIRED (120 LF SPECIFIED)
7/29/20
4" PERFORATED PVC
(HOLES DOWN)
DRAINFIELD ROCK
5'
6"ORIGINAL GROUND
6"
MOA APPROVED SAND3'-0"
4'
6"
GEOTEXTILE FABRIC
REMOVE CLAY LAYER FOUND IN TEST HOLE NO. 1 AT 7' TO 8'
IN ITS ENTIRETY AND REPLACE WITH MOA APPROVED SAND.
Municipality of Anchorage
On-site Water and Wastewater
REVIEWED FOR CODE COMPLIANCE
OSP201241, Deb Wockenfuss, 07/29/20
LEGAL DESCRIPTION:
PERFORMED FOR:
DATE:
PARCEL ID#:
SOILS LOG AND PERCOLATION TEST
TECHNICIAN:
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
DEPTH
(feet)
PROJECT No.:
TEST HOLE 1
SLOPE
SLOPE
SITE PLAN
DATE READING GROSS TIME
(minutes)
NET TIME
(minutes)
DEPTH to
WATER NET DROP
PERC. HOLE DIA. (INCHES)PERCOLATION RATE: (MIN/INCH)
TEST RUN BETWEEN: FT. and FT.
COMMENTS:
(inches)(inches)
Elmore #2, block 11 lot 4
5/6/2020
Mason Jakubisin
DATE OF MONITORING:
WAS GROUND WATER ENCOUNTERED?
DEPTH TO WATER AFTER MONITORING:
IF YES @ WHAT DEPTH? 12'
0.27 6
3 4
018-173-29
Leszek LK General
9:53
5/6
1
2
3
4
5
6
3 - 9
9:55
10:00
10:04
10:08
10:10
OB
Professional Engineers Stamp:
7/24/20
1:08
YES
11'
5/13/20
GM (SANDY SILTY GRAVEL)
CLAY LAYER
6
3 - 91:19 6
3 - 91:23 6
3 - 91:30 6
3 - 91:32 6
3 - 91:37 6
GM (SANDY SILTY GRAVEL)
Percolation test measurements were taken to the 1/16 th inch increment.
Municipality of Anchorage
On-site Water and Wastewater
REVIEWED FOR CODE COMPLIANCE
OSP201241, Deb Wockenfuss, 07/29/20
LEGAL DESCRIPTION:
PERFORMED FOR:
DATE:
PARCEL ID#:
SOILS LOG AND PERCOLATION TEST
TECHNICIAN:
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
DEPTH
(feet)
PROJECT No.:
TEST HOLE 2
SLOPE
SLOPE
SITE PLAN
DATE READING GROSS TIME
(minutes)
NET TIME
(minutes)
DEPTH to
WATER NET DROP
PERC. HOLE DIA. (INCHES)PERCOLATION RATE: (MIN/INCH)
TEST RUN BETWEEN: FT. and FT.
COMMENTS:
(inches)(inches)
Elmore #2, block 11 lot 4
5/6/2020
Mason Jakubisin
DATE OF MONITORING:
WAS GROUND WATER ENCOUNTERED?
DEPTH TO WATER AFTER MONITORING:
IF YES @ WHAT DEPTH? 10'
0.25 6
3 4
018-173-29
Leszek LK General
10:16
5/6
1
2
3
4
5
6
3 - 9
10:17
10:19
10:20
10:22
10:27
OB
Professional Engineers Stamp:
7/24/20
0:52
YES
9'
5/13/20
SANDY GM
6
3 - 91:00 6
3 - 91:12 6
3 - 91:09 6
3 - 91:25 6
3 - 91:09 6
7 10:29 3 - 91:30 6
Percolation test measurements were taken to the 1/16 th inch increment.
Municipality of Anchorage
On-site Water and Wastewater
REVIEWED FOR CODE COMPLIANCE
OSP201241, Deb Wockenfuss, 07/29/20
, A, GR,r ,ER ANCHORAGE AREA B0"qUGH
~IIlID% --
l~llll~~ ' Department of Environmental Quality
v 3330 C Street
Anchorage, Alaska 99503
INSPECTION REPORT ON-SITE SEWAGE DISPOSAL SYSTEM
NAME ./~r~,,~'~' ~,,~7/~'~C. ,.~ MAILING ADDRESS ,~"~y ~7~ ~'~-~/ PHONE
LOCATION ~,./~//~/~.c. ;~ /~,7-~ LEGAL DESCRIPTION
SEPTIC TANK:
DISTANCE /o~'J~
FROMWELL'~-"~/~'~'~'JvlANUFACTURER 5'~.c~_ _('~',~,z~ MATERIAL
INSIDE LENGTH ~ INSIDE WIDTH -- / LIQUID DEPTH
NUMBER OF
COMPARTMENTS
I IQUID CAPACITY_ /~"~-~'~ GALLONS.
SEEPAGE PIT=
NUMBER OF PiTS / DIAMETER OR WIDTH //,~ "~
-~' -- LENGTH ~" , DEPTH. /~
LINING MATERIAL~,/~b[~RIB SIZE: DIAMETER ~ ~EPTH
~ DISTANCE FROM= WELL
BUILDING FOUNDATION ~/,~ NEAREST LOT LINE ~ ~ TOTAL EFFECTIVE
· ABSORPTION AREA (WALL AREA) .~
ADDITIONAL ABSORPTION
WELL=
BUILDING NEAREST
FOUN~ ~ E
CESS~OL , OTH~CES
APPROVED DISAPPROVED
D_F~TH DISTANCE FROM:
CONSTRUCTION NEAREST ~'- SEPTIC ~AGE
REMARKS
DISTANCES:
DIAGRAM OF SYSTEM
'\
INSTALLED BY: J'('4/~'~'/~/,¢,
/ ·
PiPE MATE RIAL: ~.-~_~_~
LOT SLOPE:
REMARKS:-~-~
Focm No. EQ-031
DATE
~/ / / G.A.A.B.
TYPE AND SIZE OF' FACILITY TO I~E SERVED -
F~NANCED TNROUG~
SO.. TEST RESULTS
COMPLETION DATE ANTICIPATED
SEWAGE DISPOSAL SYSTEM -- APPLICATION AND PERMIT
GREATER ANCHORAGE AREA BOROUGH ,..~--/~//?~:,z.
DEPARTMENT OF' ENVIRONMENTAL QUALITY PERMIT NO,
3330 "C" STREET ANCHORAGE, ALASKA 99503
TELEPHONE ~74~561
OTHER
FINAL INSPECTION: 24 HOUR NOTICE REQUIRED. BACKFILLING OF ANY SYSTEM WITHOUT FINAL INSPECTION BY THE
DEPARTMENT OF ENVIRONMENTAL QUALITY AUTHORITY WILL BE SUBJECT TO PROSECUTION.
MINIMUM DISTANCES. REQUIR~'MENT~
SEPTIC TANK TO SEEPAGE PIT WALL -/ ~--
SEPTIC TANK SEEPAGE PIT ~ O ·
WELL TO S~IC TANK /0 0 t
sE~,c T^.K.//0 ~ SEEPAGE P,T/'O ~ D.^,. ,,ELD
DIAGRAM OF SYSTEM
'On= re. is wo.;~ a :ho~san,~ o?;n;ons"
: "Performed Fo~
'.- Legal
Descrintion: Lot ~ Bloc
'' Date Performed 14 May.1974
11Subdivision Wl~ S,~h~v~n~ ~
Percolation Test
This Korm Renorts Soils Log Yes
' mm Feet Soil'~haracteristics
:'I'"1'-- Tan Silt & Overburden '
Alternate 1/layers of clay tn.p)
& Eravel (G.M;) ' · ..
Grave~
Clay (M.L.).
· 225
Gravel (G.M.)
W~s..Ground Water Encountered? Yes
I¢.Ves, At what Depth? 11 Feet
'Bottom test hole.13~'
'Reading DateI Gross Time Net Time Depth to H20 'Net Dro~
''
Percolation Rate Minute
Proposed Installation: Seeoaq~. Pit Drain Field
: De~th of Inlet Depth To Bottom Of.Pit Or 'Trench
;. CAHPE~TS:~ 2~0 square ~'ee~ ~raznage area reqqlred per~ bedroom
.Waber.cao£e '~lleeb ce±ow groun~ s~r£ace
Performed 8y_ Nell A. Hausam" Data Certified By:_Constructi°n Tehtl~l