HomeMy WebLinkAboutTURNAGAIN PARK BLK 1 TR 10Onsite File Turnagain Park Block 1 Tract 10 #018-242-04 Per 2010 COSA, 2002 upgrade was never installed. 1994 trench shortened to accommodate house addition. Septic is only sized for 3 bedrooms. /0 - 3)- 2,.2 @ 12.;6)2, MUNICIPALITY OF ANCHORAGE Development Services Department On -Site Water & Wastewater Program 4700 South Bragaw Street P.O. Box 196650, Anchorage, AK 99519-6650 (907) 343-7904 ON-SITE WASTEWATER DISPOSAL SYSTEM PERMIT Upgrade Permit Number: SW020268 Legal Description: TURNAGAIN PARK BILK 9 TR 10 Date Issued: Aug 01, 2002 Expiration Date: Aug 01, 2003 Parcel ID: 018-242-04 Design Engineer: 0070 KND Engineering Site Address: 014500 OLD SEWARD HWY Owner Name: Charles Laurence Lot Size: 44060 SQ. FT. Owner Address: 14500 OLD SEWARD HWY Total Bedrooms: 4 Permit Bedrooms: 4 ANCHORAGE, AK 99515-4151 This permit is for the construction of: [_]Disposal Field F/] SepticTank ❑ Holding Tank ❑Privy ❑ Private Well ❑ Water Storage All construction must be in accordance with: 1. The attached approved design. 2. All requirements specified in Anchorage Municipal Code Chapters 15.55 and 15.65 and the State of Alaska Wastewater Disposal Regulations ( 18AAC72 ) and Drinking Water Regulations ( 18AAC80 ). 3. The engineer must notify DSD at least 2 hours prior to each inspection. Provide notification by calling (907) 343-7904 ( 24 hours ). ( Not required for a Water Supply Permit only ). 4. From October 15 to April 15, a subsurface soil absorption system under construction during freezing weather must be either: A. Open and closed on the same day. B. Covered, sealed, and heated to prevent freezing. 5. The following special provisions. PROPERTY OWNER MUST PROVIDE THIS OFFICE WITH A PROPERTY OWNER MAINTENANCE AGREEMENT PRIOR TO THE INSPECTION REPORT APPROVAL FROM THIS OFFICE. Received By: Issued By: Date: Date: Municipality of Anchorage Development Services Department Building Safety Division '- On -Site Water and Wastewater Program 4700 South Bragaw St. P.O. Box 196650 Anchorage, AK 99519-6650 www.ci. anchorage. a k. us (907) 343-7904 ON-SITE SEWER/WELL PERMIT APPLICATION FOR A SINGLE FAMILY DWELLING Parcel I.D. 018-242-04 Permit Number SW,020 268 Property owner(s) Charles Laurence Day phone 345-3612 Mailing address Code Legal description (Lot, Block & Sub d) rur-oft row Po'e It 0 i/ L I o Legal description (Section, Township & Range) Lot Size 1.0095/43,975 Acres q.FV Number of Bedrooms 4 THIS APPLICATION IS FOR: Sewer Only ❑ Well Only ❑ Sewer and Well ❑ Water Storage ❑ Sewer Upgrade THIS PROPERTY CONTAINS: Hot Tub ❑ Jacuzzi ❑ Swimming Pool ❑ Water Softening Unit ❑ Therapy Pool ❑ I certify that the above information is correct. I further certify that this application is being made for a Single Family Dwelling and is in accordance with applicable Municipal Codes. (Signature of properwowner or authorized agent) Permit Fees: oca Waiver Fees: Date of Payment: (7 Date of Payment: Receipt Number: 7>q:) Receipt Number: (Rev. 12/00) T.SPURKLAND 1P. E. 203 W 15th. Avenue, Suite 203 ANCHORAGE, ALASKA 99501 (907)279-3916 Fax (907)-276-6013 SEPTIC SYSTEM DESIGN TR10 BLOCK 1 TURNAGAIN PARK S/D CHARLESLAURENCE Municipality of Anchorage Development Services Department Building Safety Division On -Site Water and Wastewater Program 4700 Bragaw Street Anchorage, Alaska 99519-6650 November 11, 2002 We are submitting a revision to SW020268 for an upgrade of the septic system for this lot. The owner has decided to install a standard septic system. The submittal consists of three (3) drawings showing the present improvements on the lot and the adjoining properties, (sheet 1/3), the proposed improvements of the lot, of which only the septic system is subject to this permit application, (sheet 2/3), and a schematic of the septic system, (sheet 3/3). Soil logs and percolation tests of applicable test holes are also enclosed. The septic system design is based on the following : No Ground Water or Impervious Layer to 12 ft. Use Standard 5 -Wide Trench Soil Rating. From Testhole 11/07/02 6 min/in = 0.8 gal per sq.ft/day No. of Bedrooms 4 Required Area per Bedroom: 15010.8 = 187.5 sq.ft. Total area required: 187.5 x4--750 sgft Use 4 ft of sewer rock Reduction Factor 0.54 Minimum Trench Length 750 *.54 / 5 = 81 ft. Use 2-40 ft trenches SYSTEM CONFIGURATION STANDARD 5 -WIDE TRENCH TOTAL LENGTH 81 FT TOTAL WIDTH 5 FT TOTAL DEPTH 6 FT ROCK DEPTH 4 FT COVER 3 FT SEPTIC TANK 1250 GAL EXISTING The installation of this septic system will not prevent wells and septic systems from being installed on the adjacent lots. There are no developed or natural surface / sub surface drainage courses on this or the adjacent lots. The proposed septic system will not change the general slope of the area. Ponding and/or concentration of surface runoff will not result from this installation. TRACT 9 , , NEW 1RENCHty , . Z0STANDARD 5—WIDE TRENCHES 40 FT LONG 1 6 TT DEEP < FT SEWER ROCK TH VO 0 EXISTING 1250 GAL �SEPIIC TANK \ \ a DIVERTER VAL7{ EX/., TRACT 10 -(�- well NO TRACT 11 ,;f-i<E. 1' = 50 FT, I 03 W STH. AVENUE P.L. I I TR 10, BK 1 TURNA GAIN PARK I I SEPTIC SYSTEM DESIGN ANC W AK. AVENUE DATE: N17V 11, 2002 ANCH. AK. 99501 CHARLES LA pn mirNCE SHEET. 2 3 GRID. 3033 L9n7) 779—.1.916 lssnn n1n SFWdBO NM,NWdV � PERMIT # SVO20268 PID # 018-242-04 TAPOII021DVG r Standard Trenches+ 5' Wide 40' Long 6' Deep 4' Sewer rock 3' Cover ,vu """ BENCH MARK. TOP OF WELL CASING ASSUMED ELEV. 100,00 ITOBBEN SPURKLAND P.E. I ( TRIO, BKJ, TURNAGAIN PARK I I SEPTIC SYSTEM SCHEMATIC I An Wrath Ave AnSAGVON AVENUE DATE, N11V, 11, 2002 Anchorage Ak 99501 RICHARD MARSTD SHEET, .?/.? GRID. 3033 PERMIT # SWO20268 PID # 018-242-04 TAP02103DWG Municipality of Anchorage %��P; INEEKSI&IgoVkvj0 f" Development Services Department .k �49� •:.� � Building Safety Division ••may«•«•«•M•• - On -Site Water and Wastewater Program '-• 4700 South Bragaw St. •�• �� «•«« P.O. Box 196650 Anchorage, AK 99519-6650 www.cs.anchorage.ak.us 4• S C6�222! S $� (907) 343-7904 ��.tiy • t4�'^ / Soils Log - Percolation Test Performed For: Ci.1A,- i{ g 11— u -C • t e– Date Performed 1®,10'7 PAYK Legal Description: L'0* 10 3k1 t V YHL�r1at n Township, Range, Section: Depth 1 ��/j C�✓LEt�lNILS 2- 3- 4- o - - 3-4 C_ Dale Dane _ 7_ . g;I�M gowicY IF YES, A7 WHAT DEPTH? o Deplh to Water After P Monitoring? E 10- 12UiCL 1- 11;t� io�4 I 13- 13% 13J T 0 M 0 i= T IO 1A L --L 14- 1u� 15- I 9 16- I �j 10 1 7- 3 1 18- to q 20- C&MMEN T S WAS CP.OUND WATER Dale Dane ENCOUNTERED? Depth to Water Net Drcp IF YES, A7 WHAT DEPTH? o Deplh to Water After P Monitoring? E Dale: 12UiCL L Reading Dale Dane Gross Time Net Time Depth to Water Net Drcp tl-vl-aZ P%L 30Al t o a :o - 3 11;t� io�4 I 13% IO 9 1u� 3t� to I 9 1n3 I �j 10 Q 3 1 I to q os 1n q ► X14 PERCOLATION RATE _(riautes'rri) Y[r(I. Y.V!tUu:r.i_lor. (p TEST RUN BETWEEN_ 4 FT AND j FT ^� I PERFORMED EY: P, CERTIFY THAT THIS TEST N/AS ' . cJ PERFFORMED IN ACCORDANCE WITH ALL STATE AND MUNICIPAL GUIDELINES IN EFFSCT OM THIS DATE DATE Irjl �B L I ND ENGINEERING, INC. 20441 PTARMIGAN BLVD. EAGLE RIVER, AK 99577-8736 (907)696-8111 July 25, 2002 Municipality of Anchorage Development Services Department On -Site Water & Wastewater Program P.O. Box 196650 Anchorage, AK 99519-6650 Subject: New sewer/well permit — Turnagain Park Block 1, Lot 10 Gentlemen: The owner has requested we proceed forward to obtain a septic permit on the subject lot. The owner is expanding his house and will only be utilizing a 25portion of each of the existing trenches. The reduction in the size of the trench that is needed for the existing house will be achieved by installing an advantex system, AX -20. Additional bedrooms are not going to be added. The general slope of this lot is from north to south at a grade of approximately 0-5%. We propose to place the advantex system directly in-line with the existing system, leaving the old tank in place. The lot is served by an individual well, located on the eastern portion of the lot. There are no public or private wells within 200' of our proposed system location except as noted. There is no surface water within 100' of the proposed system and there are no known curtain drains within 50'. We do not expect there to be any adverse effect on adjacent lots by the development of this system. If you have any questions, please contact me at 696-6111/FAX 696-8111. Respectfully submitted, 914D Engineering Kenneth M. Duffus, P. . Attachments: On -Site Well and Sewer Application Wastewater Absorption System Details/Site Plan WELL & WASTEWATER DISP❑SAL SYSTEM DETAILS/SITE PLA IILJILIIN LL I AILS! 4 BDRM X 150 GPD = 600 GPD APPLICATION RATE = 6 GPD/SQ.FT. MIN. ABSORPTION AREA = 600 GPD/ (6 GPD/SQ.FT.) = 100 SQ.FT, 100 SQ.FT. / 5' WIDE = 20' TRENCH USE 1 TRENCH 5' W x 20' L x .5' D. USE A PORTION OF THE EXISTING TRENCHES SIZEi 2 R 5' W x 25' L x 0.5' D. ORENCO PACKAGE SYSTEM; 1. INSTALL 1500 GAL SEPTIC TANK W/ INTEGRATED ADVANTEX SYSTEM - OR TANK WILL BE SIZED PER ANCHORAGE TANK FOR A 4 BDRM RESIDENCE. 2. INSULATE TANK, EXCEPT BELOW ADVANTEX PADS TO ALLOW HEAT TRANSFER. 3. NO AIR LINE REQUIRED. NOTES: NO PUBLIC WELLS WITHIN 200. OF 1. INSULATE IF<4' OF COVER, PROPOSED SYSTEM. 2. INSULATE ALL LINES, SYSTEM COMPONENTS, TRENCH AND TANK NO PRIVATE WELLS WITHIN 200' OF PROPOSED SYSTEM EXCEPT AS NOTED. WITH 2' HD BURIAL FOAM. NO PRPOSEDC SYSTEMS WELL EXCEPT HAS NOTEDIN 200' , 3. ADDITIONAL FILL WILL BE ADDED OVER SYSTEM TO ACHIEVE MIN. 3' COVER IF REQUIRED. 4. THE CONTRACTOR SHALL HAVE THE SYSTEM LAYOUT STAKED BY A REGISTERED LAND SURVEYOR PRIOR TO CONSTRUCTION. THE CONTRACTOR SHALL VERIFY ALL SEPERATION & SETBACK REQUIREMENTS PRIOR TO CONSTRUCTION. �� OF `�<Q,jti , PREPARED FOR. '�' ` CHARLES LAURENCE 14500 OLD SEWARD HWY, SCO.LE'l 1'= 100' * L� TH * ANCHORAGE, AK. (907) 345-3612 PAGE 1 OF 3 F 1 ICE/ CE -7118 a / t r Ao t+` / \PROFE33I0�� ` FIELD BOOKS COMPUTED: BWNDARr. DRAM: MING VBG STAIGNQ CHECKm+ KMD AMUILT: DATE: 7 25 DMD, FILE CND. 3033 ACAD FILE: 02055.DWG 'IDB N" 02055 ENGINEERING 20441 PTARMIGAN BLVD. EAGLE RIVER, AK 99577-8738 m I WASTEWATER DISPOSAL SYSTEM DETAILS TURNAGAIN PARK, BLOCK 1, LOT 10 KNo L EXISTING 1250 AL SEPTIC TANK s,EAVE IN PLACE PROPOSED 15N GI SEPTIC TANK VkT INTEGRATED AD TREATMENT SYSTE (AX -20) 100' WELL I LEAVE THE PO OF TRENCHES T IS ENCROAC G ON THE PROP D ADDITION OF AL.4 1 �* 4-q 1H *, CE -7118 f !/, AV tbFESS1O�Wdgr PREPARED FOR: CHARLES LAURENCE 14500 OLD SEWARD HWY. ANCHORAGE, AK. (907) 345-3612 FIELD BOOKS BOUNDARY: FLEMIt• BrAKINR ASBUILP. DNC. FILE ACAD FILE: nonce COMPUTED: DRANK: CHECKED: DATE. GRID: Joe No.: 02055 Scale: 1'= 30' PAGE 2 OF 3 lINlBV J UJJ ENGINEERING 20441 PTARMIGAN BLVD. EAGLE RIVER, AK 99577-8736 11 Adv�nTex Treatlment System Lop View Plum Dns No. Tank Opening my (RSV) EW View i ��CIT,44-- OF ��5�1 PREPARED FOR: 1 CHARLES LAURENCE 14500 OLD SEWARD HWY. Sciatel NTS *H * ANCHO345E36AK. PACE 3 OF 3 /KE 1 / ...sss111ENGINEERING CE -7118 $�,�� \ / �DFE33IOly�' .� FIELD BOOKS ODMPU7EO: 20441 PTARMIGAN BLVD. EAGLE RIVER, AK 99577-8736 eauNGARr. FLE ING DRANK: VBG STAKING: CHECKED: KMD ASGUILT DAM 7 25 02 ONIG. Fll£ GRID: 3033 (907)696-6111/FAX (907)696-81 1 ACRD Fl`02055.DWG " Nm: 02055 16T C_ Municipality of Anchorage Page I of '2 - DEPARTMENT OF HEALTH AND HUMAN SERVICES ENVIRONMENTAL.SERVICES DIVISION P.O. Box 196650 • Anchorage, Alaska 99519-6650 0 Telephone: 343-4744 On -Site Wastewater Disposal System and/or Well Inspection Report Permit Number: Sw9&i0/CLi PID Number: 0424/Z04 Name: P C .AR Le S ANN ENCE Wastewater System: ;9 New El Upgrade Address: ABSORPTION FIELD S ' E.UR 2ccE Phone: �5/L '3217 No. of Bedrooms: ❑Deep Trench I&$hallOW Trench ❑Bed ❑Mound ❑Other ,te oJZ.4G•E K LEGAL DESCRIPTION Soil Rating: Total Depth from original grade: /•Z GPD/ . Ft. 5' 4s* 7-RAc7- Block: _ Subdivision: Depth to pipe bottom from original grade: Gravel depth beneath pipe /O R V4C_41,U 5/1 Ft. / Ft. Township: Range: Section: Fill added above original grade: Gravel length: —� -- 0 - /' Ft. 97 Ft. WELL: C9 New ❑Upgrade Gravel width: Numberoflinas: Distance between lines: S Ft. 2• 16 Ft. Classification (Private, A,B,C): Total Depth: Cased To: Total absorption area: Pipe material: F910 PERF. PR V4 RO Ft. I 80 Ft. SS7 SG. Ft. .467-M P3031Y AV. 4• Driller: s� L7�/NE iD/2KLIA)C, Date Drilled: G '2 -94/ Static Water Level: 1 S3 Ft. Installer: Eff" //6gf6S GCruS%: Date installed: (o -/G -99 Yield: I Pump Set at:Casing Height Above Ground: TANK 20 GPM Ow Ft. 2. Ft. SEPARATION DISTANCES IaSeptic ❑Holding ❑&T.E.P. To Septic Absorption Lift HoldingPublic/Private Manufacturer: I Capacity in gallons: From Tank Field Station Tank Sewer Lines O fibE NK /25() Welt' / P(, / / 3S � ,— _, , 2.5 '1' Material: STEEL Number of Compartments: 1 2- Surface f — LIFT STATION /00'+ /eo LotSize in gallons: Manufacture. Line 27 t 101 — Foundation / "Pump on" level at: "Pump off" level at: TlIzzalarm at: /0 /01 Curtain NONE KNt7 N Pump Make &Model Electrical Inspections performed by: Drain BENCH MARK Remarks: Location and Description: - Irm - TO? OF G41R9GE Fl_wrz 9/.4B Assumed Elevation: dd• OU - ENGINEER'S SEAL -. a - � f ma S 3 S ENGINEERING�e4 •, €, 17034 Eagle River Loop Road, No. 204 i Inspections performed by: Vagle m„ -r, etaska 99577 Dates:1 st (o -/s -94 . •> 2nd -16, ' A. snake Department of Healt H ervices approval - �e„ Z`"11�' Reviewed by: Dater ,��� and approved 72-013 (Rev. 9/91) MOA 25 Permit No. SW940 154 Page 2 of 2 Municipality of Anchorage DEPARTMENT OF HEALTH AND HUMAN SERVICES ENVIRONMENTAL SERVICES DIVISION P.O. Box 196650 * Anchorage, Alaska 99519-6650 9 Telephone: 343-4744 On -Site Wastewater Disposal System and/or Well Inspection Report Legal Description TURNAGAIN PARK SUBID., BLOCK 1, TRACT 1 PID No.: 01824204 72013 A (1193(' C01 CO2 95.2' FIN 04MT 6MT ............... ............... ........... 111TSVUTrON­' .............. ....... .......... .......... NEW 1250 s GAL 98.4' S.T. .......... .............. ................ ................................... ........... . ..... ...... ..... .............. ............................. FCO —A 23.0 B 26.5 —C COI 27.5 26.0 CO2 34.6 27.0 A84.5' NO WATER ;FOUND CO3 67.0 220 C04 — 39.5 25.5 O06 — 49.0 38.0 MT1 — 37.5 26.5 VT2 — 465) 3001 --- ------------ ---- .. ........... N NEW 1260 GAL SEPTIC TANK WELL. .................... .............. ............. ... ... ..... ........ ­­­ .. .. .. .. .. . . . .......... .............. ............. ­ A NEW 100 4 BDJRM HOUSE C FCO cot 04 FNMNrzt L MT 0 03 NEW DRAIN— SCALE I" 40"; c f A. UbVOW- 14174 72013 A (1193(' 07/05/9; 09:55 $ RECEIVED JUN 2 2 1991 ^e-AVIAM INC WCII DELL HOPIES P.01 STATE OF ALASKA DVARTMENT OF NATURAL RESOURCES DIVISION OF WATER WATER WELL RECORD BOROUGH So DNISION OT wBLOCK SEOTiON OtttS SECTION TOWNSHIP FAkOE MERIDIAN � I If llt'rTo VI YrI(i 13N OF LOCATION/SKETCH: WELL OWNER: f DEPTHS MEASURED FROM:❑casing top Clground surfaoe WELL DEPTH: DATE OF COMPLETION Dapth of t;ote:, ,`�,�._--•-,.•,It BOREHOLE DATA: Depth Depth of casing:F•� ft _�* _/-� / �/ Material Type and Color From To �T -_— / I IC./ -7 Y.. c, DEP}{ 0 STATIC WAR LEVEL: , �.,} it helc�h• t top of casing ❑ground surface c' f METHOD OX DRILLING: [A'alr rotary FJ cablo tool <.)/Z(i-'jAr. y r�— C� ❑other — ��� dornasuc L7 irn. align 0 monitor USE Of WELL:d ❑.publi'=supply CJ alba:•-•--...",_,-� ------ ^, _ x"{_� CASINO $1ICK UP° It, Diam; i? in. to is ft yj ..In. Y Casing type 1�"�r*to+9t WELL INTAKE OPENINQ TYf'F:.r open end ❑ screened Q parfo:atcd ❑ open hole Depths of openings: to It SCREEN TYPE: S_lotylvlesh Size _ Length:__ it --_—�-� GRAVEL PACK T'r'FC:._......._.� .o....�......�.�........ - __— -------- Volume Usad: Depth to topes, {/ROUT TYPE: —_� — Dapth: from it to tt DEVELOPMENT 1`JtETHOD of Anch age Duration:_ _ y _ fl_„____ 4, pslily ,apt. Healthtam & ees — — PUMPING LEVEL AND YIELD, Z f• after hr5min pu� t m W_p gam.- ®P PUMP INTAKE DEPTH; _ It Horsepower: _ WELL DISINFECTED UPON COMPLETION? YES CI NO CONTRACTOR INFORMATION/ REMARKS: Regisiq a Business Na9lo ` w r PLEASE MAIL WHITF COPY OF LD CI: r ' !•<-.p '°.L _tom ` •� DNR/DIVISION OF WATER �;: pnmuro o ut orae esprewilative pate PO BOX 77211 s EAGLE RIVER AK 99677.2116 MUNICIPALITY OF ANCHORAGE DEPARTMENT OF HEALTH AND HUMAN SERVICES P.O. BOX 196650, 825 "L" STREET, ROOM 502 ANCHORAGE, ALASKA 99519-6650 ON-SITE WELL AND WASTEWATER DISPOSAL SYSTEM PERMIT PERMIT NUMBER:SW940154 DESIGN ENGINEER:S & S ENGINEERING OWNER NAME:LAURENCE CHARLES & ANN OWNER ADDRESS:6820 TENENA CIRCLE ANCHORAGE, AK 99516-3217 PARCEL ID:01824204 LEGAL DESCRIPTION: TURNAGAIN PARK BLK LOT SIZE: 44060 (SQ. FT.) NUMBER OF BEDROOMS: 4 THIS PERMIT: 4 1 TR ]k0 I THIS PERMIT IS FOR THE CONTRUCTION OF: DISPOSAL FIELD /SEPTIC TANK / WELL SYSTEM ALL CONSTRUCTION MUST BE IN ACCORDANCE WITH: PAGE 1 OF 1 11 `.LY S'4nb DATE ISSUED: 5/31/94 EXPIRATION DATE: 5/31/95 1. THE ATTACHED APPROVED DESIGN. 2. ALL REQUIREMENTS SPECIFIED IN ANCHORAGE MUNICIPAL CODE CHAPTERS 15.55 AND 15.65 AND THE STATE OF ALASKA WASTEWATER DISPOSAL REGULATIONS (18AAC72) AND DRINKING WATER REGULATIONS (18AAC80). 3. THE ENGINEER MUST NOTIFY DHHS AT LEAST 2 HOURS PRIOR TO EACH INSPECTION. PROVIDE NOTIFICATION BY CALLING 343-4744 (24 HOURS) . 4. FROM OCTOBER 15 TO APRIL 15 A SUBSURFACE SOIL ABSORPTION SYSTEM UNDER CONSTRUCTION DURING FREEZING WEATHER MUST BE EITHER: A. OPENED AND CLOSED ON THE SAME DAY B. COVERED, SEALED AND HEATED TO PREVENT FREEZING 5. THE FOLLOWING SPECIAL PROVISIONS. SPECIAL PROVISIONS: RECEIVED BY: ISSUED I DATE:—G DATE : s j May 17, 1994 ROBERT SHAFER, P.E. ROGER SHAFER, P.E. CIVIL ENGINEERS (907) 694-2979 FAX 694-1211 HEALTHAUTHORITY APPROVALS Municipality of Anchorage DEPARTMENT OF HEALTH AND HUMAN SERVICES 825 'L' Street P.O. Box 196650 SEWER&WATER Anchorage, Alaska 99519-6650 MAIN EXTENSIONS REFERENCE: Turnagain Park Subdivision; Tract 10 SEWER & WATER INSPECTION Request you issue a permit to drill a well and install a septic system ENGINEERING STUDIES to serve the proposed four bedroom house on the referenced property. ANDREPORTS Two test holes were excavated and percolation tests performed. The approximate locations of the test holes are located on the attached site plan. The monitoring tubes within the test holes have been WELLINSPECTION checked and found to be dry. & FLOW TEST This property has enough area for a future septic upgrade which can be seen on the attached site plan. We do not anticipate any adverse effects on neighboring properties by the installation of the proposed SITE PLANS septic system. If you have any questions, or require additional information for your review, please contact us. ROAD DESIGN Sinc ly, SOILTEST PERCOLATION TEST STRUCTURAL& MECHANICAL INSPECTIONS ON SITE WASTEWATER DISPOSALSYSTEM DESIGN , P.E. 17034 NORTH EAGLE RIVER LOOP • SUITE 204 • EAGLE RIVER, ALASKA 99577 W 0 =I� U) z A/ 0 wz Qoo \\ _ N QN Wza� ! �N j�vwia d z �Qz Log a� oza3c�r IoM NJKZ>-�� tnJw\ zLLp w�w ~} wwY>aI IN -O rw o- � QvI�NOwo Qz \ w=N Nf/1ZZ �-Ky \ owwQ0 z�o� wz Jzmm �w�- �oa3 Kp�w? �Z WF�U d. � 77 Z o N Z0 ww< -' Eio 0 W �F Q W W H p�p W a\N d E� 0a.0 Q ®� 0" � a W N I N W w W w Zo \ oJ\ �~yy'oswc> W dN�o (� Nbld 3115 Q y a:2 ti o y �d o ga o � a A piA Z o w 0Q� a m x \\ C\ $ \� \ y\ / �W A9 = - „6 ,.^z 4, or (ENGINEER'S SEAL) Municipality of Anchorage„ $# DEPARTMENT OF HEALTH & HUMAN SERVICES a w 625 " L" Street, Anchorage, Alaska 99502-0650` SOILS LOG - PERCOLATION TEST a!o e �,=� r HOAAGS PERFORMED FOR: DATE E Ep� LEGAL DESCRIPTION: CR. IOC FGIRNHGAIN �fNLKy�OWnship, Range, Section: C1T.�'� Municipality of Anchorage DEPARTMENT OF HEALTH & HUMAN SERVICES 825 "L" Street, Anchorage, Alaska 99502-0650 SOILS LOG — PERCOLATION TEST PERFORMED FOR: BF—a— HoyDATE RFO r' f�-- LEGAL DESCRIPTION: IKfi Municipality of Anchorage • Ye Development Services Department Building Safety Division On -Site Water & Wastewater Program 4700 Bragaw Street RO. Box 196650 /1 Anchorage, AK 99519-6650 % 1 www.muni.org/onsite (907) 343-7904 CERTIFICATE OF ON-SITE SYSTEMS APPROVAL FOR A SINGLE FAMILY DWELLING Parcel I.D. 018-242-04 COSA# OSC I(' (U �1 ) 1. GENERAL INFORMATION Expiration Date: 2 _ a g _/0 Complete legal description Location (site address) Current Property owner(s) Mailing address Lending agency Mailing address Real Estate Agent Mailing address TURNAGAIN PARK BLOCK 1, TRACT 10 14500 OLD SEWARD HIGHWAY *ANCHORAGE, AK 99515 CHARLES & ANN LAURENCE Day phone 441-4083 14500 OLD SEWARD HIGHWAY *ANCHORAGE, AK 99515 Unless otherwise requested, COSA will be held by DSD for pickup. 2. NUMBER OF BEDROOMS: 3 Day phone Day phone 3. TYPE OF WATER SUPPLY: TYPE OF WASTEWATER DISPOSAL: Individual Well Individual On-site Individual Water Storage ❑ Individual Holding tank ❑ Community Class Well ❑ Community On-site ❑ Public Water System ❑ Public Sewer ❑ The Municipality of Anchorage Development Services Department (DSD) Issues Certificates of On -Site Systems Approval (COSA) based only upon the representations given in paragraph 4 by an independent professional civil engineer registered in the State of Alaska. Certificates of On -Site Systems Approval are required for the transfer of title (except between spouses) for properties served by a single-family on-site wastewater disposal and/or water supply system. DSD also issues COSAs upon request to homeowners. Certificates of On -Site Systems Approval are valid for 90 days from the date of issue for properties served by a private or Class C well and may be reissued with new water samples. (Certificates may be reissued for a period of up to one year with valid water samples.) Certificates are valid for one year for properties served by Class A or B wells or a public water system. The Municipality of Anchorage is not responsible for errors or omissions in the professional engineer's work. 4. STATEMENT OF INSPECTION BY ENGINEER As certified by my seal affixed hereto and as of the validation date shown below, 1 verify that my investigation, based on procedures outlined in the Certificate of On -Site Systems Approval Guidelines for this application, shows that the on-site water supply and/or wastewater disposal system is (are) safe, functional and adequate for the number of bedrooms and type of structure indicated herein. ! further verify that based on the information obtained from the Municipality of Anchorage files and from my investigation and inspection, the on-site water supply and/or wastewater disposal system is(are) in compliance with all applicable Municipal and State codes, ordinances, and regulations in effect at the time of installation. Name of Firm GARNESS ENGINEERING GROUP, Ltd. Address 3701 E. TUDOR ROAD, SUITE 101 * ANCHORAGE, AK 99507 Engineer's Printed Name Engineer's Comments: JEFFREY A. GARNESS, P.E. in conducting this evaluation, GEG, LtD. attempted to provide a thorough, conscientious engineering analysis of the system in accordance with ADEC and MOA DSD Guidelines & Regulations. The reported results described the performance of the system under the conditions encountered at the time of the test, and separation distances measured to readily identifiable features. The operational life of all wells and septic systems depend on the local soils condition, groundwater levels that may fluctuate during the year, and the water usage of the family being served by the system. These conditions are outside the control of the evaluator of the system. Satisfactory test results do not guarantee future performance of the system, nor do they guarantee that there are no hidden defects or encroachments. GEG, LTD. can therefore not provide any warranty or future estimate of how long the system will continue to meet the operational requirements of the ADEC or MOA DSD. The content of this report is for the sole benefit of the owner listed above. Any reliance upon or use of this report by any other person or party is not authorized, nor will it confer any legal right whatsoever. 5. DSD SIGNATURE Approved for bedrooms. Disapproved. Phone 337-6179 Date �;-13 )1. OF q °o DO . .. ...i .f .�Y.A...ness; Q m C_E-795/3 op 0o4n^P _ ''C.%1.3J.f-u FcAQ�O u°S OFd%,; ON-SITE •:.ter WATER AND ; m= WASTEWATER ; PROGRAM Conditional approval for bedrooms, with the fIIowing stipulations: '; '•, Attachments: COSA Checklist Septic System Advisory Well Flow Advisory Nitrate Advisory l� Arsenic Advisory Maintenance Agreements Supplemental Engineer's Report Other By: L (A a l Original Certificate Date: (Rev. 11106) Municipality of Anchorage • Development Services Department s Building Safety Division On -Site Water & Wastewater Program 4700 Bragaw Street P.O. Box 196650 Anchorage, AK 99519-6650 www.muni.org/onsite (907)343-7904 CERTIFICATE OF ON-SITE SYSTEMS APPROVAL CHECKLIST Legal Description: TURNAGAIN PARK BLOCK 1, TRACT 10 Parcel ID: 018-242-04 A. WELL DATA Well type PRIVATE If A, B, or C provide PWSID# N/A Date completed 6/21/94 Sanitary seal (YIN) YES Total depth 80 ft. Cased to 80 ft. FROM WELL LOG Date of test 6/21/94 Static water level 53 ft. Well production 20 g.p.m. WATER SAMPLE RESULTS Well Log Wires properly protected (YIN) YES Casing height (above ground) 12+ in. AT INSPECTION 4/13/10 56 ft, 4.94 g.p.m. Coliform 0 colonies/100 ml. Nitrate 1.14 mg.1L. Other bacteria 0 colonies/100 ml. Arsenic: <5 ug./L. Date of sample: 5/4/2010 Collected by: GEG Ltd. B. SEPTIC/HOLDING TANK DATA Tank Type/Material SEPTIC STEEL Date installed 6/15-16/94 Tank size 1250 gal. Number of Compartments E Cleanouts (Y/N) YES Foundation cleanout (Y/N) YES Depression over tank (YIN) NO High water alarm (Y/N) N/A Date of pumping 4/13/10 Pumper MCDONALDS PUMPING C. ABSORPTION FIELD DATA Date installed 6/15-16/94 Soil rating .p.d./ r ft2/bdrm) 1_2 System type TRENCH 24 & 48.5 Length **72.5 TOTAL ft. Width 5 ft. Gravel below pipe 1 ft. Total depth *6.83 ft. Eff. absorption area4� 44 ft' Monitoring tube YES Depression over field NO Date of adequacy test 4/13/10 Results (Pass/Fail) PASS For 3 bedrooms Fluid depth in absorption field before test DRY in. Water added 980 gal. New depth 3 in. Elapsed Time: 98 min. Final fluid depth DRY in. Absorption rate >= 450+ g,p,d, Any rejuvenation treatment (past 12 mo.) (Y/N & type) NONE KNOWN If yes, give date **SEE ATTACHED LETTER. D. LIFT STATION Date installed Size in gallons Manhole/Access (YIN "Pump on" level at in. "Pump off' level High water alarm level at in. Cycles tested Meets alarm & circuit requirements? E. SEPARATION DISTANCES SEPARATION DISTANCES FROM WELL ON LOT TO Septic tank/lift station on lot 100'+ On adjacent lots 100'+ Absorption field on lot 100'+ On adjacent lots 100'+ Public sewer main N/A Sewer/septic service line 25'+ Animal containment areas 50'+ Public sewer manhole/cleanout N/A Holding tank N/A Manure/animal excrete storage areas 100'+ SEPARATION DISTANCES FROM SEPTIC/HOLDING TANK ON LOT TO: Building foundation 5'+ Property line 5'+ Absorption field 5'+ Water main N/A Water service line 10'+ Surface water 100'+ Wells on adjacent lots 100'+ SEPARATION DISTANCE FROM ABSORPTION FIELD ON LOT TO: Property line 10'+ Buildingfoundation 10'+ Water main N/A Water service line 10'+ Surface water 100'+ Driveway, parking/vehicle storage *0'+ Curtain drain NONE KNOWN Wells on adjacent lots 100'+ F. COMMENTS *SMALL PORTION OF SOUTH TRENCH IS UNDER ASPHALT DRIVEWAY. G. ENGINEER'S CERTIFICATION i certify that I have determined through field inspections and review of Municipal records that the above systems are in conformance with MOA COSA guidelines in effect on this date. Engineer's Printed Name JEFFREY A. GARNESS Date Si t I I to COSA Fee R !'r 0 Waiver Fee $ Date of Payment 5) J Date of Payment Receipt Number —7-7 -2�, 1 Receipt Number (Rev. 11105) GARNESS ENGINEERING GROUP, Ltd. CONSULTANTS & GENERAL CONTRACTORS May 13, 2010 Municipality of Anchorage Development Service Department On -Site Water & Wastewater Program 4700 Elmore Road, P.O. Box 196650, Anchorage, Ak 99519-6650 (907)343-7904 Ref: Letter in regards to Turnagain Park S/D; Block 1, Tract 10, To whom it may concern: The subject property is served by a septic system consisting of a dual trench type drainfield. On the attached C.O.S.A. paperwork, the trench length is noted as 72.5 feet. One trench is 48.5 feet long and the other is 24 feet long. The original as -built paperwork indicates 97 feet of total trench length. It is our assumption that each trench was originally 48.5 feet long. The north drainfield was shortened to accommodate an addition to the house. GEG, Ltd, exposed the northeast end of the north trench to confirm its length and install a cleanout at the end. The length noted on our C.O.S.A. paperwork reflects what we found during these inspections. If you have any qt ee ions, please contact us at 337-6179. Thank you for your assistance M.S. N07t: Attached is a site plan drawing, a design drawing, one soil log, which are all part of the design package for this septic system. (Contact G.E.G. Ltd. for 7 page construction specification letter.) 3701 E. Tudor Road, Suite 101 *Anchorage, AK 99507-1259 Ph: (907) 337-6179 * Fax: (907) 338-3246 * Website: www.gamessengineering.corn Page 1 of 1 Crewdson, James A. From: Jeff Garness [Jeff@garnessengineering.com] Sent: Monday, May 17, 2010 9:24 AM To: Crewdson, James A.; Wockenfuss, Deborah M.; Poet, Jeff W. Subject: Turnagain Park, B1, Tract 10 (14500 Old Seward Highway) We submitted a COSA on 5/14/2010 for Turnagain Park, Block 1, Tract 10 (14500 Old Seward Highway). Although we didn't note it on the COSA paperwork, the north (48.5 long) trench is full, so we only tested the 24 foot long segment (south trench), which performed adequately. Please call or email if you have any questions ............ Jeff Jeffrey A. Garness, P.E., M.S. President Garness Engineering Group, Ltd. 3701 East Tudor Road, Suite 101 Anchorage, Alaska 99507-1259 Ph: 907-337-6179 Fax: 907-338-3246 email: jeff@garnessengineering.com website: www.garnessengineering.com 5/18/2010 v-im �0Co d� / Dm� �oNm al` Zoe d --i d izo =0A O m z = O m m o AOO p� \ a m 11 L Cid \ o\d OHO \ z \ 1 00 2 �� \ O �1 SepticVents Oo'� \ )7 VO \ o ti \ Os Qc� � o o ';,SeA�OL s N 0�e 9 \Gi �cA OO INS :.` eors a �oeQ O= wycol` 0$ ,;• \� `r0 �-0 A 77 s �� V, o \ o Vehts m m ~ � D \ m ° m ��- \\ -Zi O,ir, \ o Y \ Q 4°A "4.- D z O m A O �. a�, C1� m o O QD m Gam' w 2 1 dq ro many W o° ?ps<gwww 'D W'io- T1 wo m wno.o3� 5 m 0o o Nwa�.mm-c nZmm co'o 0 m -wo Dom >x m m wo mwss..mm �D�w W<_ n / •d m So m m_m_m �+m ;a Zro7' �m m O w rn^o op w L. ODas ID m oom S9w �+ p w A N O . O m m - N O- N tp d �. S (O m.mv'o�°'v �mw O8 m•n m m oP 0 3000 m maw OOo m 5 a o w D �.m o meso s�M p03mo Za (� a.wwmow D 1Da.� An D �mw > _ Z-) ERI w ti r n a w T��]7w m9 - _ Nm ooa 3 0 -Um Qpd D`Gad �`Ot� ND oN o �o mo•�a� ZW Wm p� W w N O O m D O 0 a`��� 0605 m W D �5 m bZ�� W N? j CO 0 Ut O V � MUNICIPALITY OF ANCHORAGE DEPARTMENT OF HEALTH i£ HUMAN SERVICES Division of Environmental Services On -Site Services Section P.O. Box 196650 Anchorage, Alaska 99519-6650 343-4744 CERTIFICATE OF HEALTH AUTHORITY APPROVAL FOR A SINGLE FAMILY DWELLING Parcel I.D. # ° (� a y ° HAA # 14A 9 L" 13 1. GENERAL INFORMATION - - Complete legal description Tract 10; Skock 1; Tunnaga.in Pa)tk Location (site address or directions) Property owner Se,U 1Homea Day phone 345-2355 Mailing address 18622 Gui.Uemo.t C.inc?o Anchpnaqp, AK 99;IA Lending agency Mailing address. Agent Address Unless otherwise requested, HAA will be held for pickup. 2. NUMBER OF BEDROOMS: 4 3. TYPE OF WATER SUPPLY: Individual well XXX Community well Public water Day phone Day phone NOTE: If community well system, provide written confirmation from State ADEC attest- ing to the legality and status of system. 4. TYPE OF WASTEWATER DISPOSAL: Individual on-site XXX Holding tank Community on-site Public sewer NOTE: it community wastewater system, provide written confirmation from State ADEC attesting to the legality and status of system. 72-=(Rev.1/91) Front MOA521 5. STATEMENT OF INSPECTION BY ENGINEER As certified by my seal affixed hereto and as of the validation date shown below, I verify that my investigation of this Health Authority Approval application shows that the on-site water supply and/or wastewater disposal system is safe, functional and adequate for the number of bedrooms and type of structure indicated herein. I further verify that based on the information obtained from the Municipality of Anchorage files and from my investigation and inspection, the on-site water supply and/or wastewater disposal system is in compliance with all Municipal and State codes, ordinances, and regulations in effect on the date of this inspection. Name of Firm 5 & S ENGINEERING Phone 6 y — a -1 7 17034 Eagle River Loop Road DO# _ Address Engineer's signature 6. DHHS SIGNATURE t f Approved for 4— bedrooms. Date 111-7 1 9� Disapproved. Conditional approval for bedrooms, with the following stipulations: Additional Comments The Municipality of Anchorage Department of Health and Human Services (DHHS) issues Health Authority Approval Certificates based only upon the representations given in paragraph 5 above by an independent professional engineer registered in the State of Alaska. The DHHS does this as a courtesy to purchasers of homes and their lending institutions in orderto satisfy certain federal and state requirements. ,Empioyees of DHHS do not conduct inspections or analyze data before a certificate is issued. The Municipality of Anchorage is not responsible for errors or omissions in the professional engineer's work. 74-025OW.IM) Beek MOAN41 Municipality of Anchorage Department of Health and Human Services HEALTH AUTHORITY APPROVAL CHECKLIST Legal Description: NICT /ter �U/?NAGA/N //1t K Parcel I.D. ZIA 6 c% A. Well Data Well type MUA-74� If A, B, or C, attach ADEC letter. ADEC water system number -44— Log present") —Date Date completed 6 1�/Gl'/!l 9y Driller /iE Total depth Cased to gds Casing height Sanitary seal (YEN) Wires properly protected (Y/N) FROM WELL LOG Date of test ('6-1 bq Static water level 53 Well flow off() g.p.m. Pump levell S 1 SEPARATION DISTANCES FROM WELL TO: Septic/hofdiag-tank on lot /86, M AT INSPECTION t — / BCW '.iL o z I'T'I y Z r D M 9.p -m. co < z r -n " N .A c Q o N G O n On adjacent lots /DO 'i- z Absorption field on lot / 3S ; On adjacent lots mo 'J Public sewer main /U /,4 Public sewer manhole/cleanout /v/a Sewer service line d Petroleum tank No?,J _ WATER SAMPLE RESULTS: Coliform --6Leolon,4511o17,/ Nitrate 0. % / rreqlL Other bacteria O �7 _ Date of sample: /( i`1 Collected by: S �lUist/flN� B. SEPTICS TANK DATA Date installed 6/ bV Tank size �aSU Compartments Z Cleanouts (4)N) W -S Foundation cleanoutY(Y)N) Depression (Y/A /U1 High water alarm (Y/6 IU /,J/A Alarm tested (Y/@ ��% Date of pumping /i�Jii — IUE-W /AN Pumper N4 SEPARATION DISTANCES FROM SEPTIC/H@L"tNG TANK TO: Well(s) on lot (86 On adjacent lots l Od ,f Foundation /U 1 To property line Absorption field 30 ('�- Water main/service line Surface water/drainage 106 72-026(3193)'Front CONTINUED ON BACK PAGE C. LIFT STATION h Date installed Manufacturer Size in gallons \ Manhole/Acce Vent (Y/N) "Pump on" level "Pump off" Level at High water alarm level \��les tested Meets MOA electrical codes (Y/ \ SEPARATION D NCE FROM LIFT STATION TO: Wel lot On adjacent lots Surface water D. ABSORPTION FIELD DATA Date installed -r l id %L( Soil rating (GPD/Ftz) 142. System type wicra w, Length f ( Width 5 ( Gravel thickness r'r Total depth 5 Total absorption area S Cleanout present &N) rf Depression over field (Y/W Date of adequacy test �Jg , Results (pass/fail) AUAfor 4 Bedrooms Water level in absorption field before test /U�/) After test /U/, Peroxide treatment (past 12 months) (Y(N)) Yv If yes, give date A1% SEPARATION DISTANCE FROM ABSORPTION FIELD TO: Well on lot I?SrSl On adjacent lots / ori V Property line /d To building foundation ! To existing or abandoned system on lot h/ 4 On adjacent lots ar, Cutbank t16 V Water main/service line � Surface water 9()b'4- Driveway, parking/vehicle storage area a�,< Curtain drain E. ENGINEER'S CERTIFICATION / certify that I have checked, verified, or conformed to all MOA and HAA guidelines in Signature d� 20t� Engineer's Name �p 9�.e; C ` Date )) /7 `r y HAA Fee $ v b 1� � 60 Date of Payment Receipt Number77 72-026 (3/93)` Back Waiver Fee $ Date of Payment Receipt Number SWT C. Cx7*AAY' C` Cc -8801 ............. ,\ ' inspection.