HomeMy WebLinkAboutTURNAGAIN PARK BLK 1 TR 12A
Municipality of Anchorage page
; DEPARTMENT OF HEALTH AND HUMAN SERVICES
ENVIRONMENTAL SERVICES DIVISION
P.O. Box 196650 · Anchorage, Alaska 99519-6650 · Telephone: 343-4744
On-.Site Wastewater Disposal System and/or Well Inspection Report
Permit Number: ~., '~o~. PID Number: o0 s - ~ ,4= - I '~
~,,,e: Oo-, ~.~, ~,c. ~/o ¢=o.r-r Wastewater System: [3 New I~l Upgrade
^ddr..: .~e¢~-~ ~"%. ABSORPTION FIELD
Phone:('~.o~,,,- I~t IN°'o'~r"ms: ,DeepTrench DShatlowTrench DBed DMound DOther
Total ~pth from original grade:
LEGAL DESCRIPTION so,,,.,.0: o.e o,o,sq ~
Town,hip: ~ Range: ~ ~ ~tion: Fill add~ a~ original grade: Gm~l length:
~ O - I Ft ~W ' Ft.
WELL: ~,~,.~New D Upgrade ~.lwidth; ~ Ft. I · Ft.
yle~Pump ~t ,C ~ing ~,ght A~ Gr~nd; TAN K
SEPARATION DISTANCES ~s.,t,~ ~ Ho~.~ ~ sm[P.
Wei~ JOo I+ Jool~ -- -- ~1~ Matedah ~E;~
s~,~ - LIFT STATION
Water Ioo1+ ~oo1+ ~
Lot Size In gallons: ~ Manufa~ure~
Foundation ~t' ~' -- --
BENCH MARK
Remarks:
Inspections pe~ormed by: s & s EN~INEEEIN~ "' ~
~le River, Alibi ~5~ 2nd 1-~-~C ,k~ t RO~.T C COw~
~epadment of Healt~ Hum~ices a~proval ~:~.
Reviewed and approved b Date.
72-013 (Rev. ~91) MOA 25
Permit No.
2 2
SW960163 Page of
Municipality of Anchorage
DEPARTMENT OF HEALTH AND HUMAN SERVICES
ENVIRONMENTAL SERVICES DIVISION
P.O. Box 196650 · Anchorage, Alaska 99519-6650 · Telephone: 343-4744
On-Site Wastewater Disposal System and/or Well Inspection Report
TRACT 12A TURNAGIAN PARK S/D PIDNo' 018-242-14
Legal Description: .................... · .......
FCO 38.~' 17.5'
ST1 64.')' 66.0'
ST2 72.)' 73.5'
DBL1 7.3. ~' 75.5' ~'e,,. \ \ ·
C01 1100' 107.5'
MT1 1090' 108.0' f
C02 109 .5' 1.31.0'
MT2 110 5' i.31.5'
ALT. SIT
( )2 = 88.t'
0 WATER ~'dO~ 6-i0-96
MUNICIPALITY OF ANCHORAGE
DEPARTMENT OF HEALTH AND HUMAN SERVICES
P.O. BOX 196650, 825 "L" STREET, ROOM 502
ANCHORAGE, ALASKA 99519-6650
ON-SITE WASTEWATER DISPOSAL SYSTEM (UPGRADE)
PERMIT NUMBER:SW960163
DESIGN ENGINEER:S & S ENGINEERING
OWNER NAME:CRAIG DONALD E
OWNER ADDRESS:14440 OLD SEWARD }{WY
ANCHORAGE, ALASKA 99516
PARCEL ID:01824214
PAGE i OF i
DATE ISSUED: 7/01/gb
EXPIRATION DATE: 7/01/97
LEGAL DESCRIPTION:
TURNAGAIN PARK BLK
i TR 12A
LOT SIZE: 56652 (SQ. FT.)
NUMBER OF BEDROOMS: 4 THIS PERMIT:
THIS PERMIT IS FOR THE CONSTRUCTION OF:
DISPOSAL FIELD /SEPTIC TANK SYSTEM
ALL CONSTRUCTION MUST BE IN ACCORDANCE WITH:
1. THE ATTACHED APPROVED DESIGN.
2. ALL REQUIREMENTS SPECIFIED IN ANCHORAGE MUNICIPAL CODE CHAPTERS
15.55 AND 15.65 AND THE STATE OF ALASKA WASTEWATER DISPOSAL
REGULATIONS (18AAC72) AND DRINKING WATER REGULATIONS (18AAC80).
3. THE ENGINEER MUST NOTIFY DHHS AT LEAST 2 HOURS
PRIOR TO EACH INSPECTION. PROVIDE NOTIFICATION BY
CALLING 343-4744 ( 24 HOURS ) (NOT REQUIRED FOR WELL ONLY PERMIT)
4. FROM OCTOBER 15 TO APRIL 15 A SUBSURFACE SOIL
ABSORPTION SYSTEM UNDER CONSTRUCTION DURING FREEZING
WEATHER MUST BE EITHER:
A. OPENED AND CLOSED ON THE SAME DAY
B. COVERED, SEALED AND HEATED TO PREVENT FREEZING
5. THE FOLLOWING SPECIAL PROVISIONS.
SPECIAL PROVISIONS:
RECEIVED BY: ~~~
DATE:.
ROBERT C. COWAN, RE.
ROBERTA. SHAFER, P.E.
CIVIL ENGINEERS
June 12, 1996
(907) 694-2979
FAX (907) 694-1211
$O~TEST
MUNICIPALITY OF ANCBORAGE
Department of ~ealth and Buman Services
P.O. Box 196650
Anchorage, AK. 99519
REFERENCE: Tract 12A, Turnagain Park Subdivision
Request you issue a permit to upgrade the septic system
serving the existing four bedroom house on the referenced
propez~cy.
A test hole was excavated and percolation test performed.
The approximate location of the test hole is located on the
attached site plan.
At the time of excavation no water was encountered and
after seven day ground water monitoring, water was found at
14 feet.
Attached is the proposed upgrade design.
This property has enough area for a future septic upgrade
which can be seen on the attached site plan.
We do not anticipate any adverse effects on neighboring
wells, septic systems or drainage patterns by the
installation of the proposed septic system.
If you require additional information, please contact us.
Sincerely,
Robert C. Cowan, P.E.
RCC/gk
Enclosure
o
17034 NORTH EAGLE RIVER LOOP ',' SUITE 204 · EAGLE RIVER, AI.ASKA 99577
LEGAL TRACT 12A, TURNAGAIN
DESIGN CRITERIA:
~l~l~IEEl~lll~ 4 BDRM = 600 GPD
SOILS = 0.8 OPD/SO.FT.
TRBNCB CRITERIA:
PARK SUBDIVISION
JDATE6-- 12-96
8' DEeP
6' EFFECTIVE'
3' WIDE
62.5' LONG
)POSED 1250
SEPTIC TANK
TRACT 13
TRACT
?
ALT.
%
EXISTING SEPTIC TANK
USPECTED LOCATION OF
EXISTING CRIB AND TRENCH,
(EXACT LOCATION UNKNOWN)
TRACT
J SliT. 1 OF !
, \
O,
TRACT 11
CLIENT
STRUCTURES, EASEMENTS, OR ENCROACHMENTS
SHOWN ON THIS SITE PLAN ARE AS SNOWN ON
AN AS-BUILT SURVEY DRAWN BY:
TRYCK, NYMAN, & HAYES
IT IS THE RESPONSIBIUTY OF THE CONTRACTOR
TO VERIFY EASEMENTS, REQUIRED SEPARATION
DISTANCES. AND PROPERTY UNES PRIOR TO
CONSTRUCTION.
~FERENCE:
ROBERT C. COWAN, RE.
ROBERTA. SHAFER, RE.
ON-SITE WASTEWATER DISPOSAL SYSTEM
CONSTRUCTION PRACTICES
and
MATERIAL SPECIFICATIONS
CML ENGINEERS
(907) 694-2979
FAX (907) 694-12~1~1
~ENERAL:
1o
4°
.5.
3.
Tract 12A, Turnagain Park Subdivision
June 12, 1996
The scope of this project includes the installation of
a 1250 gallon septic tank and a leachfield trench to
serve the four bedroom residence located on the
referenced property. The existing crib and trench are
to be abandoned as such that they may be used in the
future. The existing septic tank is to be excavated,
pumped, crushed, and abandoned completely.
Construction shall be in accordance with the approved
site plan and design drawings, Municipal permit with
any special provisions or conditions, and all
applicable State and Municipal Wastewater Disposal
Regulations.
The contractor shall be responsible for obtaining any
necessary underground utility locates.
Unless specifically agreed otherwise, the property
owner shall be responsible for final grading areas
subsequently depressed from soil settling.
Contractors installing wastewater disposal systems
must be certified by the Municipal Health Department
for system installations. Owners installing their own
systems must also receive prior approval from the
Municipal Health Department.
~EPTIC TANK INST~?.T.~TION:
A septic tank is tc be constructed by a certified
septic tank manufacturer. Construction shall include
two 4" cleanouts for pumping access.
The septic tank shall be sufficiently bedded to
prevent settling or shifting of the tank.
Ail standpipes on the septic tank shall extend a
minimum of 12 inches above final grade.
17034 NORTH EAGLE RIVER LOOP · SUITE 204 * EAGLE RIVER, ALASKA 99577
Page Two
Tract 12A, Turnagain Park Subdivision
June 12, 1996
Septic tanks installed with less than 4 ft. of cover shall
be insulated.
A foundation cleanout shall be installed one to four feet
from the building foundation. In the line between the tank
and the leachfield there shall be two adjacent cleanouts
(unless an effluent pumping system exists within the septic
tank). These cleanouts shall be located on undisturbed
soil not more than 10 ft. from the tank. The first
cleanout, in line, shall be to clean toward the leachfield.
The second cleanout shall be.to clean toward the septic
tank.
Final grading over the septic tank shall be such that a
positive slope exists away from the septic tank.
ABSORPTION TRENCH/DRAINFIELD INST~.T.%TION:
Excavate the proposed trench to the dimensions shown on the
design. The bottom of the excavation shall be within 2
inches of level. If the sidewalls of the excavation become
smeared, they must be raked or scratched (ruffed-up) before
gravel (sewer rock) placement.
Once the gravel is installed, the distribution pipe is to
be installed level with the perforations faced downward.
Gravel is then to be placed over the distribution pipe to
provide a minimum of 2 inches of cover over the pipe.
A silt barrier must be installed between the final gravel
layer and the native soil backfill. Ensure the silt
barrier covers the entire gravel surface before placing
backfill.
e
Monitor tubes shall be of four (4) inch diameter,
installed approximately in the locations shown on the
design, and extend a minimum of 12 inches above final
grade. The portion of the monitoring tube extending
through the gravel shall be perforated from the bottom of
the trench to the invert of the distribution pipe. This is
equivalent to the effective depth of the gravel as noted on
the design.
Page Three
Tract 12A, Turnagain Park Subdivision
June 12, 1996
Backfill over the final gravel layer must not be less than
twenty-four (24) inches. Insulation must be installed when
the backfill depth is less than thirty-six (36) inches.
The finish grade over the trench must be mounded to prevent
the formation of a depression after settling.
MINIMUM MATERIAL SPECIFICATIONS:
me
Any septic tank proposed for installation must be
constructed by a Municipally approved septic tank
manufacturer.
The following pipe materials are approved for use in septic
system installations in the Municipality of Anchorages
Type of Pipe
Perforated Solid
Cast Iron Yes Yes
ASTM D3034 (PVC) Yes Yes
ASTM F810 (HDPE) Yes No
ASTM D2662 (ABS) Yes Yes
Use of a type of pipe other than listed above must be
approved by the inspecting engineer.
0
Insulation shall be at least 2" thick extruded direct
burial polystyrene (Dow Chemical Company Styrofoam HI or
equal).
e
Septic tank inlets and outlets shall be fitted with
watertight couplings (Caulder, Fernco, or equal).
A permeable nontoxic silt barrier (Typar 3401, Mirafi 140N,
or equal) must be installed between the final leachfield
gravel layer and the native soil backfill.
6. Ail leachfield gravel (~ewer rock) shall be 0.5"-2.5"
screened gravel with less than 3% passing the ~200 sieve.
7. When sand is being used as a filter material, its gradation
specifications must conform to current M.O.A. or D.E.C.
requirements.
Page Four
Tract 12A, Turnagain Park Subdivision
June 12, 1996
INSPECTIONS~
Typically there will be a minimum of three (3) inspections
required during the installation of the wastewater disposal
system. These inspections will occur as follows:
The first inspection must be conducted after the
excavation of ditches, pits, trenches, or beds and
before the installation of any gravel. A septic tank
may be set in place, but may not be backfilled before
this inspection.
0
The second inspection must be conducted after the
placement of the silt barrier, gravel, distribution
lines, standpipes, cleanouts, and insulation, but
before the placement of any other backfill.
The final inspection is to occur upon final grading of
the property.
Often there will be more than these 3 inspections required.
Especially with the installation of multiple trenches, sand
filters, pressurized distribution systems, etc. Thus, the
inspecting engineer is to be contacted at least 24 hours prior
to the start of construction. If necessary, a pre-construction
meeting will take place on-site. The inspecting engineer will
not coordinate, direct or control in any way the contractors
activities.
The owner shall contract with the contractor to perform the work
outlined in these specifications and plans and in accordance
with the attached M.O.A. permit. There will be no contractual
arrangement existing between the contractor and S & S
Engineering. S & S Engineering shall be the owner's
representative and will inspect the work as stated above to
document the contractors activities. Final acceptance of the
contractors work rests with the owner and the M.O.A.
Page Five
Tract 12A, Turnagain Park Subdivision
June 12, 1996
S & S Engineering shall have no liability to the owner or to
others for acts or omissions of the contractor or any other
persons performing work on this project or the failure of the
contractor to carry out the work in accordance with these
construction documents. S & S Engineering's inspecting engineer
will not be responsible for the construction means, methods,
techniques, sequence, procedures or the safety precautions
incident to this project.
CONTRACTOR/INSTALLER
Municipality of Anchorage
DEPARTMENT OF HEALTH & HUMAN SERVICES
825 "L" Street, Anchorage, Alaska 99502-0650
SOILS LOG -- PERCOLATION TEST
PERFORMED FOR:
LEGAL DESCRIPTION'T
~,% .o,,r c cow^,
,,;,.,.. ,...-,-.,,. ....-,..~,,~
~,~ ~. . ... -,.?.,
DATE PERFORME~:' "~5~ '/':-~./.../.,~ G~-
· .: ...... -.,,'
/M.4 K
Township, Range, Section:
2,
3
4
5
6
7
8
9
10
11
12
13
14-
15-
16.
17.
18-
19-
20-
COMMENTS
/v) L $ ~L 7"
WAS GROUND WATER /V O
ENCOUNTERED?
IF YES. AT WHAT SL
DEPTH? ~ p~
E
~elath m Waer/Bier
Momtoring? J '~ ~' f~itt
SLOPE SITE PLAN
Gross Net Depth to Net
Reading Date Time Time Water Drop
Glt /~C, q: 3 S"a~ -- G"
PERCOLATION RATE ~:) (m,nute~mch) PERC HOLE DIAMETER ~ "
TEST RUN BETWEEN 4 '/~- FTAND 7 '/~. FT
PERFORMED BY: _S &S ENGINEERING I CERTIFY THAT TH~S TEST WAS PERFORMED IN
17034 E~gle River Loop Road No. 204 /~' ' ~/~ o / q (=
ACCORDANCE WIT~,~~ GUIDELINES IN EFFECT ON THIS DATE DATE;
72~ [R~. 4/~)
MUNICIPALITY OF ANCHORAGE
DEPARTMENT OF HEALTH & HUMAN SERVICES
Division of Environmental Services
On-Site Services Section
P.O. Box 196650 Anchorage, Alaska 99519-6650
343-4744
Parcel I.D. # CI~' -3"J ~ - IV
1. GENERAL INFORMATION
Complete legal description
CERTIFICATE OF HEALTH AUTHORITY
APPROVAL FOR A SINGLE FAMILY DWELLING
HAA#
12A,, '&~rn~gain Park Su~ivision
Location (site address or directions)
14440 Old S~ward Hwy.
Anchor~e, AK
Pr6perty owner ' .Donald Crai~
Mailing address 7683 S.E. 27th f286
Day phone,
Mercer Island, WA
(206) 954-1881
98040
Lenc~ing agency .......
Mailing address "
Day phone
Agent
Address .... '
Day phone
Unless otherwise requested, HAA will be held for pickup.
NUMBER OF BEDROOMS:
TYPE O~ WATER SUPPLY:
Individual well
Community well
Public water
NOTE:
If community well system, provide written confirmation from State ADEC attest-
ing to the legality and status of system. .'.
4. TYPE OFWASTEWATER DISPOSAL:
NOTE:
Individual on-site
Holding tank
Community on-site
Public sewer
If community wastewater system, provide written confirmation from State ADEC
attesting to the legality and status of system.
5. STATEMENT OF INSPECTION BY ENGINEER
As certified by my seal affixed hereto and as of the validation date shown below, I verify that my
investigation of this Health Authority Approval application shows that the on-site water supply
and/or wastewater disposal system is safe, functional and adequate for the number of bedrooms
and type of structure indicated herein. I further verify that based on the information obtained from
the Municipality of Anchorage files and from my investigation and inspection, the on-site water
supply and/or wastewater disposal system is in compliance with all Municipal and State codes,
ordinances, and regulations in effect on the date of this inspection.
Name of Firm
Address
Engineer's signature
S & S ENGINEERING
~7G3-; ;..~, ;.;v,r Loop koad NO. 204
Eagle River, Alaska 99577
Phone
Date '7/! -/ /g ~'
DHHS SIGNATURE
Approved for ~
Disapproved.
Conditional approval for
bedrooms.
bedrooms, with the following stipulations:
By:
Additional Comments
Date ,~'./,~./"~
The'Municipality of Anchorage Department of Health and Human Services (DHHS) issues Health Authority
Approval Certificates based only upon the representations given in paragraph 5 above by an Independent
professional engineer registered in the State of Alaska. The DHHS does this as a courtesy to purchasers of homes
and their lending institutions in order to satisfy certain federal and state requirements. Employees of DHHS do not
COnduct inspections or analyze data before a certificate is issued. The Municipality of Anchorage is not
r~Donsible for errors or omissions In the professional engineer's work.
~IVIRO~I~.NrAL SBWlCES
Municipality
of
Anchorage
DEPARTMENT OF HEALTH & HUMAN. SEFIVlCEI~ J~.l~
Environmental Services DivisIon '
825 L Street, Room 502 · Anchorage, Alaska 99501 · (907)
Health Authority Approval Checklist
Legal Description: 7',~/~ C7-/'2./'~ .~ ~'~,a/,//¢4~/~-/,./ Parcel I.D.:
WELL DATA
Well type
Log present (Y/I~.
Total depth /,/'x~,~'4/c~.~4,/ Cased to
If A, B. or C. attach ADEC letter. ADEC water system number
Date completed /~'.4/~,4/
Casing height (above ground) ~ / ~''
Wires properly protected (~t~l) ,~v'~-"~
/1/O
Date of test
Static water level
Well production
WATER SAMPLE RESULTS:
Coliform
FROM WELL LOG
AT INSPECTION
g.p.m.
Nltmto I · 6 ~- Other bacteria
Date of sample: '~-/~--~)~ Collected by: ~._..~,5"' ~--'/~'G.~'/.,/~'._.~',~x~
B.~OLDING TANK DATA
Date installed '~ -~'"~ ~ Tank size /Z..CO ~',4/ Number of Compartments Z . Cleanouts (~N) ,,v~c'-~'
Foundation cleanout ~)N) y~c-~' Depmscion (Y/I~ ~u' o High water alarm (Y/N~, ,/V o
Date o. tPumplng~E',-J'~. ,~ Pumper /~/,//~,
C. ABSORPTION fiELD DATA '
Date InstaJled 7 -9 - ~ ~' Soil rating ~or ~/bdrm) 4:~ . ~' System type ~'~"E/'~
Le.gn ~x7.~' '
Width -~ Gravel thickness below pipe &" /
, To~ depth,
E".=~..t=orptio. ama ~.! 'O / Mo.,orin; ~be pr. ent ~) >'~'-< Dep~io. o~; ,o~d ~'~
Date of adequacy test ,'~'~'~' ~,',v5 ,"[,~ Results (Pass/Fail) /u', .,~. For /-7/ bedrooms
Fluid depth In absorption field before test (in.); ,/~'- ~- Immediately after/~',~gal, water added (in.): ,,~', ,4.
Fluid depth /t/./~. (ins) Minutes later: /~/' '~/' Absorption rate = /c/. / · g.p.d.
PamXl=le treatment (past 12 months) (yA~'J)/ /~,'~ If yes. gt~e dato
724)26 (Ray.
Date installed ~. Size in
Manhole/Access (Y/N) ~~ 'Pump off' level at'
High water alarm level at*
SEPARATION DISTANCES FROM WELL ON LOT TO:
f~cJ~olding tank on lot
Absorption field on lot
On adjacent lots
On adjacent lots
Public sewer main ~' '~ ' Public sewer manhole/cleanout
Sewer/septic service line
SEPARATION DISTANCES FROM ~LDING TANK ON LOT TO:
Foundation ~
Property line ,~ ~/'' Absorption field
Water main/service line /'~? x,~ .Surface water/drainage IP~ ~' Wells on adjacent lots
SEPARATION DISTANCE FROM ABSORPTION FIELD ON LOTTO:
Property line /~ /'~ Water main/ssrvice line
Building foundation /~;' /~'
Surface water .' .! ~0 "f''~ Dri~way, parking/vehicle storage ama
Curtain drain
~.~,v~ · . ~,~¢ ,.. ~., Wells on adjacent Iote /~c~
ENGINEER'S CERTIFICATION
Yu field inspections and review of Municipal records ~ am
,certify that I have determined it
Engineer's Name
HAAFee $ ,,"~-J"~ -~)
Date of Payment '~//~ 7/~'
Receipt Number -I~-A
Waiver Fee $
Data of Payment
Receipt Number
72-026 (Rev. 3/9S)*
CT&E Environmental Services Inc.
Laboratory Division ~-t~-~-~-.~-~-t.~.~-~..~.~-~.~.~.,~.t,~.jtjjjjfjjtjjjjtjjjjj~
4
Drinking Water Analysis Report for 5'6tal Coliform Bacteria ~oo w. ~ctt~r Ur~o
Anchorage, AK 99518-1 605
~.~4D Ii¥~TgFC2~ION~ ON )CEYE]C~E SIDE BEFOE CO£££CTIh'~ SA~V~LE Tel: {9071 562-2343
Fax: (907} 561-5301
TO BE COMPLETED BY LA~OR~TORY
[ [ Analysis shows this Water S)dMPLE to be:
MUST B£ COMPLETED BY WATER. SUPPLIER
PUBLIC WATER SYSTEMLO.# ~' I I I I
PRIVATE WATER SYSTEM
$¢nd lnvoice
C~ Send Jnvolce
~ Send~esultt
Month Day Year
SAMPLE TYPE:
~!~ Routine C1 Treated Water
~ Repeat Sample (for routine sample Cl Untreated Water
with lab ref. no, )
~ Special Purpose
Time Collected
SAM. PLE LOCATION Collected By
Satisfactory
n Unsatisfactory
Sample over 30 hours old, results may
be unreliable
Sample too long in transit; sample should
not be over 48 hours old at examination
to indicate reliable results. Please send
new sample via special delivery mail.
Date Received ~'~ ~'"~/1o~
Time Received
Analysis Began =,
Analytical Method: ~ Membrane Filter
~ MMO-~G
' Number ofcolonie~100 mL
' Ol ~o. Result*
Sent to A.D.~C. ~ Fb~ Jun
CHent notified of unsatisfactoO. results:
Phoned Spoke with
Date: ~mc:
Faxed
[]
Faxed
COmments:
BACTERIOLOGICAL WATER ANALYSIS RECORD
I~IMO-MUG Result: Total Coliform
Membrane Filter: Direct Count
· Verification: LTB
Fecal Coliform Confirmation .
Final Membrane Filter Results
BGB
F-.. Coil.
(~ Colonies/100 mi
COLIFIRM
% I?/96 1~:~6 CT~E ESI AN(~AF~ ~ 9~69~1~11 NO. 1~%
CT&E Environmental Services Inc,
Laboratory D;vi$ion ~e'~J'~',~ramr~' ~r~e'.~,.~.~J-~'~-~'J-,~,e-.~.~,~.~ .-~. :
· ;~,~i'.# 962528.962825001
'~ rn~:¢ ID Lot 12A Tur~igan Park $/D
Dri,king Wat~r
200 W. Potter Dr~ve
Anchorage. Al( 99515-1 ~ :~:
Tel: (907) 562-2343
Fax: (907) 561-5301
Collected Date 07112/96
Technical Director; $ttphen C. Ede
1.65 0.100 mO/L EPA 353.2
LT · Less then
................. ..~.~ Member of the SOS Group ($od4H4~ G0n6rale de Surveillance}
' ' 'J;:?~FAL FACILITIES IN ALASKA. CALIFORNIA, FI.OR]DA. ILUNOI$, MARY~4.ND, MICHIGM4, MISSOURI. NEW JERSEY', ~)HIO. *~';~'J~ .... .
29 June. 196~
fir. Donald Crala
,25 5th ~venue
Anchcraae. Alaska
Track 12
Turnacain
SUBJECT~ Alkyl-benzene-sulfonate Te~
Dear ~r. CralE~
A Bach Test performed by the Creater Anchorage Bealth District on the water
supply located at Track 12, Tutmagaln Park indicated ~n absence of alkyl-benzene-
sulfonate (commonly referred to as detsr~ent).
By
CPJ ~ cw
~ I '-2, - MUNICIPALITY OF ANCHORAGE
DEPARTMENT OF HEALTH & ENVIRONMENTAL PROTECTION
ENVIRONMENTAL HEALTH CASE REVIEW WORK SHEET
~ ~-I PLATTING BOARD [] PLANNING & ZONING
CASE NUMBER NAME
S-5789 Tract 12A Turnagain Park Subdivision
DATE RECEIVED
June 30, 1981
COMMENT TO PLANNING BY
July 13, 1981
FOR MEETING OF CASE OF
EATE R N4,.~,,T,~VAI LABLE TO PETITION AREA
WER N~T, AVAILABLE TO PETITION AREA
(Rev. 2/78)