Loading...
HomeMy WebLinkAboutTONJESS ESTATES BLK 1 LT 7Ton jess Estates Block 1 Lot 7 #051-831-11 UBMITT, Municipality of Anchorage AUG 11 Community Development Department Page On -Site Water and Wastewater Program 4700 Elmore St. • P.O. Box 196650 Anchorage, AK 99519-6650 • http://www.muni.org/onsite • (907) 343-7904 ON-SITE WASTEWATER INSPECTION REPORT Permit Number: OSP131150 PID Number: 051-831-11 ❑ New 1 2014 1 of 3 Upgrade Name: Lance Cluff & Gloria Grover ABSORPTION FIELD ❑ Deep Trench ✓Shallow ❑ Other Trench ❑Bed ❑Mound Address 24821 Jesse Lee Court Chugiak, AK 99567 Phone Number of Bedrooms 5 Soil Rating 1.2 GPD/SF Total depth from original grade 7 Ft. LEGAL DESCRIPTION Depth to pipe invert from original grade 3 Ft. Gravel depth beneath pipe Subdivision Block Lot Tonjess Estates 1 7 Fill added above original grade 1-3 Ft. Gravel length 68 Ft. Township Range Section Gravel width 5Ft. Beds: Number of Lines Distance between lines Ft. SEPARATION DISTANCES To From Septic Tank Absorption Field Lift Station Holding Tank Sewer Line Total absorption area 680 z Fl Number of trenches Two Dist. between trenches > 10 Ft. Well >100' >100' N/A N/A >25' TANK 0 Septic ❑ S.T.E.P. ❑ Holding ❑ Other Manufacturer Greer Capacity 1,5000a1. Surface Water >100' >100' N/A N/A NA Material HDPE/Plastic Number of compartments Two Lot Line >5' >10' N/A N/A Foundation >5' >10' N/A N/A LIFT STATION Manufacturer Capacity Gal. Curiain Drain None Noted Remarks Existing Septic Tank Decommissioned in Pump on level at in Pump off level at in. High water alarm at in. Accordance with Municipal Code. Punip make and model Electrical Inspections performed by Installer Dean Construction PIPE MATERIAL House to tank D3034 Tank to D3034 drainfield Drainfield HDPE CO/MT D3034 Inspector MEA BENCH MARK (Assumed elevation) 100.0ft Inspection 1st7/14/13 244 7!15/13 Location and description Bottom of Siding. 3. 7/22/13 4" COMMUNITY DEVELOPMENT DEPARTMENT APPROVAL Conditional Approval: Date : O� 1 e !� • .#1 # es -*•:4918%\ •*} t/ ! mama t. MOWN : 4 A. ttl;r: t •-43$1 .•.�ill . E 4••••• t j[T ::Iti Eot s Approves / PP / v1/,1� at u / / L Date nspection Repot] 1-1-12.doc Permit Number: OSP131150 0 z 0 z P1 -1 Municipality of Anchorage DEVEOPMENT SERVICES DEPARTMENT 4700 Elmore Road Anchorage, AK. 99519-6655 - 343-7904 TONJESS ESTATES SUBDIVISION LOT 7, BLOCK 1 51,440 SF S 89'59'51"E 219.91' Page 2 of 3 PID NO.: 015-831-11 J N N (0 04 N 00'00'09"E CLASS C WETLAND Qroximate Wetlands._. Boundary _ ALTERNATE SITE Advantex Treatment System with Existing 25' Long x 5' Wide x 3.5' Effective Depth Absorption Trench. NOTE: Existing Septic Tank Decommissioned in Accordance With Municipal Code. LOT 7 1.18 ACRES N A SI S2 C4 M1 05 C6 M2 C7 30.3' 32.2' 38.8' 39.9' 40.3' 58.4' 57.1' 56.7 B 35.9' 40.0 55.4' 79.5' 82.4' 65.8 87.8' 88.6' S2 TH1 10' DRAINAGE EASEMENT / / /1 / C6 / / N 89'59'51"W 168.10 !M2 / 1 / / / N N LEGEND: TH — Test Hole C4 — Clean Out MT — Monitor Tank M1 — Monitor Tube FSV — Flow Splitter Valve / 51 — Septic Vent O . .... JESSE LEE COURT• 49th MICHAEL E. ANDERSON /VI • I •r . NO, CE -4381 /AStfOFESSWr PLAN AS BUILT SCALE 1' = 40 Municipality of Anchorage DEVEOPMENT SERVICES DEPARTMENT 4700 Elmore Road Anchorage, AK. 99519-6655 - 343-7904 On -Site Wastewater Disposal System or Well Inspection Report Permit Number. OSP1311150 0 Page 3 of 3 PID No. 051-831-11 ,500 Gallon Se tic Tank Finished Grade 92.0 94.7 U Existing Grade Geotextile Fabric 89.0 Grainfield Rock 85.0 —le 75.0 No Groundwater 7-22-2013 Finished Grade 34' (Trench Length) 90.0 91.3 r U Existing Grade Geotextile Fabric 86.7 Grainfield Rock 82.7—"" 75.0 No Groundwater 7-22-2013 34' (Trench Length) PROFILE AS -BUILT No Scale 89.0 86.7 DEPTH (feet) 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 MUNICIPALITY OF ANCHORAGE DEVELOPMENT SERVICES DEPARTMENT 4700 BRAGAW STREET ANCHORAGE, AK 99519-6650 SOILS LOG - PERCOLATION TEST LEGAL DESCRIPTION: Lot 7 Block 1 Tonjess Estates PERFORMED FOR: Lance Cluff DATE: 7/14/13 PROJECT No • PARCEL ID#• TECHNICIAN- .1R TEST HOLE 2 OB/OG GW/SW WELL GRADED GRAVEL WITH SAND B.O.H. WAS GROUND WATER ENCOUNTERED' IF YES @ WH. DEPTH OF WATER AFTER MOt DATE OF MO SLOPE No ........... 44.,, • • 49th �7f 71/f"-1 MICHAEL HIE ANDERSON i •I ea'., No. CE -4381• vr 1N i Professional Engineers Stamp: SITE PLAN See Site Plan 4T DEPTH" L IITORING: None p VITORING: 7/22/13 E DATE READING GROSS TIME (MINUTES) NET TIME (MINUTES) DEPTH TO WATER (INCHES) NET DROP (INCHES) TEST HOLE PRES AKED PRIOR TO TESTING: 7/14/13 1 10:12 2.25" 2 10:42 30 9.50" 7.25" 3 10:43 2.00" 4 11:13 30 9.25" 7.25" 5 11:14 1.75" 6 11:44 30 9.00" 7.25" PERCOLATION RATE:4 1 (MIN/INCH) PERC. HOLE DIA. 6 (INCHES) TEST RUN BETWEEN: 4 FT. and 5 FT. COMMENTS: TEST HOLE PRE SOAKED PRIOR TO TEST. TEST PERFORMED BY ANDERSON ENGINEERING. I, MICHAEL E. ANDERSON CERTIFY THAT THIS WAS PERFORMED IN ACCORDANCE WITH ALL STATE AND MUNICIPLE GUIDELINES IN EFFECT ON THIS DATE: 8/11/14 On -Site Wastewater Disposal System Permit Permit Number: OSP131150 Tax Code Number: 05183111000 Work Type: Septic Permit Effective Dates: June 25, 2013 MUNICIPALITY OF ANCHORAGE Development Services Department On -Site Water & Wastewater Program 4700 Elmore Road, PO Box 196650 Anchorage, AK 99519-6650 Telephone: (907) 343-7904 Design Engineer: ANDERSON ENGINEERING Subdivision: TONJESS ESTATES Site Legal Address: Owner/Address: to June 25, 2014 TONJESS ESTATES BLK 1 LT 7 G:1462 CLUFF LANCE ALAN & GLORIA GROVER 24821 JESSE LEE COURT CHUGIAK AK 995675725 Site Mailing Address• 24821 JESSE LEE CT, Chugiak Lot Size in Sq Ft: 51440 Total Bedrooms: 5 This permit is for the construction of: Y Disposal Field Y Septic Tank N Holding Tank N Privy N Private Well N Water Storage All construction must be in accordance with: 1. The attached approved design. 2. All requirements specified in Anchorage Municipal code Chapters 15.55 and 15.65 and the State of Alaska Wastewater Disposal Regulations (18AAC72) and Drinking Water Regulations (18AAC80). 3. The wastewater code requires inspections during the installation. The engineer must notify the Development Services Department at least 2 hours prior to each inspection. Provide notification by calling (907) 343-7904 (24 hours). 4. From October 15 to April 15, a subsurface soil absorption system under construction during freezing weather must either: A. Open and Close on the same day. B. Covered, sealed, and heated to prevent freezing. Special Provisions: PRIOR TO CONSTRUCTION: New testholes shall be completed such that all portions of the permitted drainfield are within 30 feet of a testhole. Any revisions will require an approved change order to be obtained prior to construction. Testhole results shall be submitted with the final inspection report. Special Provisions: The permit includes waiver OSP131164 allowing the drainfield to be oriented parallel to the slope. 6 � > 24..,; Received By: ,`7 j - `� - Date: Issued By: i tivAt Date: Municipality of Anchorage P.O. Box 196650 • 4700 Elmore Road Anchorage Alaska 99519-6650 • (907) 343-7904 S Fax (907) 343-7997 http://www.m un i.org/Onsite Development Services Division On -Site Water and Wastewater Program **** VARIANCE/WAIVER REVIEW **** Waiver#: OSP131164 COSA#: Permit#: OSP131150 PID#: 051-831-11 Legal Description: Toniess Estates, Block 1, Lot 7 Engineer Anderson Engineering Applicant: Lance Cluff Your request for a waiver of the required parallel orientation of the absorption field to the slope contours has been approved. This waiver approval applies to the proposed absorption field only. Any future upgrade to the on-site wastewater disposal system will require all separation distances be met or another approval from this department. ❑ The affected adjacent property owner(s) have been given a 7 day notice regarding this waiver. ❑ Notarized letter(s) of non -objection have been received from the owner(s) of the affected adjacent property. Z Adjacent properties are not affected by this waiver. Waiver is Granted: X Date: 6403 Waiver is not Granted: Approved by, Name of Reviewer Rec#: 06756G Amount: $200.00 Date Paid: 6/25/2013 **** VARIANCE/WAIVER REVIEW **** MUNICIPALITY OF ANCHORAGE Community Development Department Development Services Division On -Site Water & Wastewater Program Phone: 907-343-7904 Fax: 907-343-7997 ON-SITE SEWER/WELL PERMIT APPLICATION Parcel I.D. 051-831-11 Property owner(s) Lance Cluff Day phone Mailing address 24821 Jesse Lee Court Chugiak, AK 99567 Site address Same Legal description (Sub'd., Block & Lot) Tonjess Estates, Block 1, Lot 7 Legal description (Township, Range & Section) Lot Size 51,440 Sq. Ft. Number of Bedrooms Five (5) APPLICATION IS FOR: (E all that apply) Absorption Field Septic Tank Holding Tank Privy Private Well Water Storage APPLICATION IS AN: Initial Upgrade Renewal TYPE OF DWELLING: Single Family (SF) (wlwo ADU) Duplex (D) Multiple Dwellings (SF and/or D) THIS APPLICATION INCLUDES A VARIANCE / WAIVER REQUEST FOR: Absorption Trenches Perpendicular to Contours of Ground. Dis tance: I certify that the above information is correct. I further certify that this is in accordance with applicable Municipal Codes. (Signature of property owner or authorized agent) Permit/Rush Fees: 4(20 Pia Date of Payment: 6 & h3 Receipt Number: O?9 '1-0 C7 Waiver Fees Date of Payment: 4/as/ 73 Receipt Number: & '?5% Cr Permit No. Oa° I S I I So Waiver No. Permit App_9-1-12.doc CUSPi3i 16741 ANDERSON ENGINEERING P.O. BOX 240773 ANCHORAGE, AK 99524 522-7773 677-7766 (FAX) June 15, 2013 Municipality of Anchorage Development Services Department On -Site Water and Wastewater Program 4700 Elmore Road Anchorage, AK 99519-6650 Subject: Lot 7, Block 1, Tonjess Estates Subdivision Septic System Design and Permit Application Impacts to Adjacent Properties Dear Onsite Services Engineer: The existing house on Lot 7, Block 1, Tonjess Estates Subdivision has been expanded to five bedrooms. We are therefore requesting a permit be issued for the upgrade of the septic system to accommodate the five -bedroom home on. The attached Site Plan and backup documentation identify the location and configuration of the existing and proposed septic system. The existing septic tank will be decommissioned in accordance with Municipal Code. The existing absorption trench will be left intact with the exception of the northwest 5' which encroaches into the well radius. The remaining portion of the trench will be the alternate site for future use as needed. Also identified on the plans are the locations of the existing well on this and adjacent lots and adjacent septic systems. No conflicts exist between the proposed septic system and the wells on this or adjacent lots. Protective radii are shown to the adjacent wells. Drainage arrows are shown indicating the current drainage patterns. The drainage patterns will be maintained after construction. The test hole placed on the lot indicated Well Graded Gravel with Sand (GW/SW). This coincides with the original test hole placed on the lot for the original septic system. The existing absorption trench is currently dry with no presence of septic effluent noted. Groundwater was encountered at 10' below the surface. The percolation rate in the soil was determined to be less than 5 minutes per inch. We have designed the new trenches with an application rate of 1.2 gallons per day per square foot. We are proposing to place 2-32' long by 5' wide absorption trenches with a 4' effective depth. The total depth of the system will vary as the trenches must be placed parallel with the slope due to the limited area available for the septic upgrade. The entire effective absorption area will remain in the GW/SW soil layer. A flow splitter valve will be placed Lot 7, Block 1, Tonjess Estates June 15, 2013 Page Two to insure even flow to each trench. The ground surface on the lot slopes from south to north area of the absorption trenches. The trenches will be placed parallel to the slope as shown on the attached drawings. A waiver is attached to allow the placement of the trenches in this configuration. A minimum of 100' will be maintained between all components of the septic system and the proposed well and from any surface water in the area. If the system is constructed in accordance with our design the following statements apply: 1. The system, if constructed as designed, will have no adverse impact on the wells in the area or those to be constructed in the future. The system, if constructed as designed, will have no adverse impact on existing septic systems in the area or those to be constructed in the future. 3. The system, if constructed as designed, will have no adverse impact on reserve space, either surface or subsurface, on any lots located in the area. 4. The system, if constructed as designed, will have no adverse impact on drainage patterns in the area. The current drainage pattern will be maintained. Sincerely, 1 / t ._ ,Zt- Michael E. Anderson, P.E. Attachments ANDERSON ENGINEERING P.O. BOX 240773 ANCHORAGE, AK 99524 522-7773 677-7766 (FAX) June 24, 2013 Municipality of Anchorage Development Services Department On -Site Water and Wastewater Program 4700 South Bragaw Street Anchorage, AK 99519-6650 Subject: Lot 7, Block 1, Tonjess Estates Subdivision Absorption Trench to Ground Contours Dear Onsite Services Engineer: Very little area remains on Lot 7, Block 1, Tonjess Estates Subdivision to upgrade the septic system. The lot is covered with heavy trees and brush and the surface slope is very irregular. The most suitable area to place the new absorption trenches runs perpendicular to the contours of the ground surface. The surface slope in the area is 5% to 10% in a south to north direction. The absorption trenches will be placed at 10' below ground at the south end and approximately 7' below ground at the north end. The organic layer in this area is approximately 1' in depth. The distribution pipe in the absorption trenches will be below the peat layer, but totally in the gravel absorptive layer. We therefore recommend a waiver be issued allowing placement of the new absorption trenches to run perpendicular to the ground slope contours. Sincerely, -- E LEE COURT \11 I =® I W / \ / 1 N m // 0 \ 1 / \ J N. -- / \ / NN. i / N. / \\ \/ \ / 1 I \ I O $1 11\ J .W : / / 1 \ I \ / I\\ / N. / \ // \\ 1.3311S NO?JNOW i TONJESS ESTATES SUBDIVISION LOT 7, BLOCK 1 51,440 SF 13381S NOdNOW tri te z S 89'59'51 "E 219.91' CLASS C Y WETLAND / I \ / / \ / / / \,___ Approximate Wetlands_. / Boundary ALTERNATE SITE 1 Advantex Treatment System with / Existing 25' Long x 5' Wide x 3.5' Effective Depth Absorption Trench. 1 LOT 7 1.18 ACRES NOTE: Decommission Existing Septic Tank in Accordance With Municipal Code. Decommission 5' of Existing Absorption Trench in Accordance with Municipal Code. 10' DRAINAGE EASEMENT �; 1 .\ \ Q� ryo� ryoa /1 O N 4/ Iryof 1 1,500 Gallon 1g / Septic Tonk 1 �MV ®H1 •_ pf E/ 200 1" CO F4R o! / ,GRAVEL DRIVEWAY 168.00 0 0 NOTE: Decommission Existing Trench to This Point. N 89'59'51"W 168 I JESSE LEE COURT No Excessive Slopes or Breaks in Topography Within 100' of the Propo ed Wastewater Systems. SITE PLAN SCALE 1" = 40' N —32' Long x 5' Wide x 4' Effective Depth Absorption Trenches. Total Depth 6' to 8'. LEGEND: TH — Test Hole CO — Clean Out MT — Monitor Tube FSV — Flow Splitter Valve SV — Septic Vent ,t1 . • .4 49th :• MICHAEL E. ANDERSON ; �: •1 Cl : No. CE -4381 r'1 " LOT 7, BLOCK 1, TONJESS ESTATES SUBDIVISION DESIGN FACTORS: Five Bedroom Horne Perc. Rate: 1-5 Min./Inch Application Rate: 1.2 GPD/SF SYSTEM REQUIREMENTS: 5' Wide Trench System 1,500 Gallon Septic Tank 4' Drainfield Rock 5 Bedrooms * 150 GPD/Bedroom = 750 SF Absorption Area 750 SF/1.2 GPD/SF/5 SF (Width) '.5 (Red. Factor)= 62.5 LF Trench Length THEREFORE: Construct 2-32' Long x 5' Wide x 4' Effective Depth Absorption Trenches. Flowline Elevation to be 6' Below Original Ground Surface at the South End and 2' Below Original Ground Surface at the North End. Flowline to be Level in Each Trench. Total Trench Depth to be 10' at South End and 6' at North End. Provide 3' of Cover Over Absorption Trenches and 4' of Cover Over Septic Tank. Place Flow Splitter Valve to Insure Even Flow to Each Trench. 5'6" 5' Geotextile Fabric 4" Perforated PVC (Holes Down) Drainfield Rock TYPICAL 5' WIDE TRENCH SECTION - (NO SCALE) ��. �E OF y.♦ NOTE: Grade Area Over Trench to Drain Away. Minimum 6' Separation From Bedrock. • Minimum 4' Separation From Groundwater. i Minimum 100' Separation From Private Wells in the Area. Minimum 100' Separation From Surface Water or Streams. a ♦'� ♦ ,r : No. CE -4381 �'S� ♦♦rF•• a 49th c4 MICHAEL E. ANDERSON t &, ll z 76 O c� 4 2 o O a"t foo °= \ @ U /_ ce CO U N a9 0 N N ct) U ~ f 'O F c r MC _ U 3 c O 2 F W o F o CO O W ==Qo Q U CO Wa 0H a a) H p =.. o N W Q > C Lll m O N H. o O C N CO w =>cj o W .77r - —1 o > CO c 0 M @ V J 0 0 0 /§ 0 a) ' U) > S C o W X=3acn m o c o ° L_ 30 z �-owe O o C L a) co N w o N H. m C Z ti - CV El) o .. N Z Y 70 r `� o ° ca 2.2 IS t H 0 o— m c O (t a d la U c 0 O o `c c MJ O w co > W w c a 0 O wca; MUNICIPALITY OF ANCHORAGE DEVELOPMENT SERVICES DEPARTMENT 4700 BRAGAW STREET ANCHORAGE, AK 99519-6650 DEPTH (feet) 1 2 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 SOILS LOG - PERCOLATION TEST LEGAL DESCRIPTION: Lot 7 Block 1 Tonjess Estates PERFORMED FOR: Lance Cluff DATE: 6/4/13 PROJECT No.: PARCEL ID#: TECHNICIAN: JB TEST HOLE 1 OB/OG GW/SW WELL GRADED GRAVEL WITH SAND B.O.H. SLOPE WAS GROUND WATER ENCOUNTERED° NO IF YES T WHAT DERTFI? DEPTH OF WATER AFTER MONITORING_ None 0 DATE OF MONITORING: 6/14/13 4 tVOF ,.. �4 1/41 49th W '. V:p MICHAEL E. ANDERSON : z: ♦✓f NO. CE -4381 ti — r' Professional Engineers Stamp: SITE PLAN See Site Plan Sas DATE READING GROSS TIME (RING -FES) NET TIME (MINUTES) DEPTE TO (INCES) NG ERHES) NET DROP (INCHES) TEST HOLE PRESOAKED PRIOR TO TESTING: 6/4/13 1 12:05 6.50" 2 12:35 30 13.50" 7.00" 3 12:36 6.00" 4 1:06 30 12.75" 6.75" 5 1:07 6.25" 6 1:37 30 13.00" 6.75" PERCOLATION RATE:4 4 (MIN/INCH) PERC. HOLE DIA. 12 (INCHES) TEST RUN BETWEEN: 7 FT. and 8 FT. COMMENTS' TEST HOLE PRE SOAKED PRIOR TO TEST. TEST PERFORMED BY ANDERSON ENGINEERING. I, MICHAEL E. ANDERSON CERTIFY THAT THIS WAS PERFORMED IN ACCORDANCE WITH ALL STATE AND MUNICIPLE GUIDELINES IN EFFECT ON THIS DATE: 6/14/13 t ( M MUNICIPALITY OF ANCHORAGE 1 DEPARTMENT OF HEALTH & ENVIRONMENTAL PROTECTION ENVIRONMENTAL ENGINEERING DIVISION 825 L Street • Anchorage, Alaska 99501 Telephone 264-4720 ON-SITE''t SEWAGEpDISPOSAL SYSTEM AND/OR WELL. INSPECTION REPORT NAME Q Dh / I S4 o t. 277- / /PHONE EW II UPGRADE MAILING ADDRF,1Bb LLI�--o / a 36 Ave. LEGAL DESCRIPTION L-7 6 / rO N . /ESS $/o / v LOCATION NO. OF BEDROOMS SEPTIC TANK 1 W7. a ( t DISTANCE TO: V Absorpt�arra.,, ..._ Dwelli.( .{.., L— M / at r / PEgIIT,t4Op7 z. 6 G No. of compartments ea Manufxmre,/fNC,/ v < Liacit�yfi/jnaallons q/ /q IF HOMEMADE: Inside length Width Liquid depth . d Y —i22 S? F DISTANCE T0: Well Dwelling PERMIT NO. Manufacturer Material Liquid capacity in gallons 0 w F 2 cc o DISTANCE TO: Well (,� /00 .� Founda yy et L, Neareir. s fir r PEH plQ Nay Z 6 No. of lines / Lengty.eJ each4*L O Total }v eS of li s ✓J Trench syiAth CCJ Q inches Distance tvk IiryZ �f„(/ /tT— Top of the fit all a ✓ 7 "tete13er/ de 2/ (mss LU 5 # inches Total elfec a�s�}w�e 'tea SEEPAGE PIT Length Width Depth PERMIT NO. Type of crib Crib diameter C ib depth Total effective absorption area DISTANCE TO: Well B ilding foundation Nearest lot line J 3DISTANCE Class Depth Driller Distance to lot line PERMIT NO. TO: Building foundation Sewer line Septic tank Absorption weals) OTHER PIPE MATERIALS ` SOIL If EST RA N �S/JJ/�� T `G £ s Q' p INSTTAA 'LER #C ,l'e4rr (ie. rads, r 1 �Ijf ca MARKS - eSagni l� ‘t 1 w�f _ �t �{` %a see.'';” / , .#/ler J✓ "$ tiAilkibPPOW- r1('7-}.r:et 41.1 APPH /% DATE LEGAL 2466, V>'s'nv •&3AIU it Z� �:>JNiHS3NIJt<� S'3 S 61 % ' 21,444-61- xc6>. N 0 7t01,i'(Rev. 3/78) t1Ut*1 I C I F•AL I TY QF RFJCIA ORIRGE DEPARTMENT SiA.I HEALTH AND ENVIRONMENTAL rOTECTION NO 825 't STREET, ANCHORAGE, AK. 99„01 1 264-4720 CrJ—SITE SEWER F•ERr1 I T rERP1IT Na ( 820726 ) APPLICANT JOHN SHORT 401 E 36 AVE 99503 279-0491 LOCATION LEGAL L7 81 TONJESS S/D LOT SIZE 999999 SQUARE FEET TYPE OF SOIL ABSORPTION SYSTEM IS: DRAINFIELD MAXIMUM NUMBER OF BEDROOMS = 3 SOIL RATING <SQ FT/BR)= 85 THE REQUIRED SIZE OF THE SOIL ABSORPTION SYSTEM IS: C'EF'TH= G. S LEF-4G11-1-1= 2S GRF1•ti'EL 1 EF'TH= THE LENGTH DIMENSION IS THE LENGTH CIN FEET) OF THE TRENCH OR DRAINFIELD. THE DEPTH OF A TRENCH OR PIT I5 THE DISTANCE BETWEEN THE SURFACE OF THE GROUND AND THE BOTTOM OF THE EXCAVATION CIN FEET). THE TREr-dcH WI CaTH IS -. B FEET_ THE GRAVEL DEPTH I5 THE MINIMUM DEPTH OF GRAVEL BETWEEN THE OUTFALL PIPE AND THE BOTTOM OF THE EXCAVATION CIN FEET). RECIU I F_EP SEPTIC TFft-4I-C S I == 1O-+cuo UALLc.N15 ' PERMIT APPLICANT HAS THE RESPONSIBILITY TO INFORM THIS DEPARTMENT DURING THE INSTALLATION INSPECTIONS OF ANY WELLS ADJACENT TO THIS PROPERTY AND THE NUMBER OF RESIDENCES THAT THE WELL WILL SERVE. --- r140 1.-:2> I t4SF•ECT I Qr-JS BF_E G!U I FEC' --- BACKFILLING OF ANY SYSTEM WITHOUT FINAL INSPECTION AND APPROVAL BY THIS DEPARTMENT WILL BE SUBJECT TO PROSECUTION. MINIMUM DISTANCE BETWEEN A WELL AND ANY ON-SITE SEWAGE DISPOSAL SYSTEM IS 100 FEET FOR A PRIVATE WELL OR 150 TO 200 FEET FROM A PUBLIC WELL DEPENDING UPON THE TYPE OF PUBLIC WELL. MINIPMUM DISTANCE FROM A PRIVATE WELL TO A PRIVATE SEWER LINE IS 25 FEET AND TO A COMMUNITY SEWER LINE I5 75 FEET. OTHER REQUIREMENTS MAY APPLY. SPECIFICATIONS AND CONSTRUCTION DIAGRAMS ARE AVAILABLE TO INSURE PROPER INSTALLATION. F'ERt1 I T EKF• I RES C]ECEt1BEE FR: 2 S. S +L 2 I CERTIFY THAT 1: I AM FAMILIAR WITH THE REQUIREMENTS FOR ON-SITE SEWERS AND WELLS AS SET FORTH BY THE MUNICIPALITY OF ANCHORAGE. 2: I WILL INSTALL THE SYSTEM IN ACCORDANCE WITH THE CODES. 3: I UNDERSTAND THAT THE ON-SITE SEWER SYSTEM MAY REQUIRE ENLARGEMENT IF THE RESIDENCE IS REMODELED TO INCLUDE MORE THAN 3 BEDROOMS. SIGNED:_ APPLICANT JOHN SHOR ISSUED BYSerg DATE 7442- --- V4. 0 SOILS LOG MUNICIPALITY OF ANCHORAGE DEPARTMENT OF HEALTH AND ENVIRONMENTAL PROTECTION 925 L. Street, Anchorage, Alaska 99501 2644720 SOILS LOG - PERCOLATION TEST ❑ PERCOLATION TEST PERFORMED FOR: 72;7;:ss /374h Q / 2k [i`�% DATE PERFORMED: I/I Lfd�'7j`7�� LEGAL DESCRIPTION: ! On f CSS • `1� k / Lof ! VV SLOPE 1 2 3 4 5 6 7 9 F RP r mar 10- 11 12 13 14 15 16 17 18 19 20 ebor/v graded hof- much •Res. gr .1/ hi I- • COMMENTS I WAS GROUND WATER ENCOUNTERED? IF YES, AT WHAT DEPTH? 4b. G ,-r pjs� E PLAN &pry. F Reading Date Gross Time Ne Time Depth to Water Net Drop PERCOLATION RATE (minutes/inch) TEST RUN BETWEEN commiond ''iu NP pc 40" PERFORMED BY: J , CA 72-008 (6/79) CERTIFIED BY: FT AND FT rocx i ATE: Ctrs fifirb Urttting King ur DOC CO. dba SULLIVAN WATER `YELLS P. O. BOX 272, CHUGIAK, ALASKA 99567 • TELEPHONE 688.2759 OWNER OF LAND C ' !' f�/,q)ii�,c «DEI rill DETII OF WELL J C r /4' AXZ 7 a `>10 DKKE"C (O#.J 4Q A.40H 9 ? STTA IC LEVEL OF WATER FT SD ADDRESS LEGALDESCRIPTION L 7 aces y04'_'ESS DATE •Started 7/F1 Ended %/tea PERMIT NUMBER DRAW DOWN FT GALS. PER HR KIND OF CASING 0900 ;o0 :UND OF FORMATION: From 0 Ft. to r; Ft. n JC g is c/.Pl1t o-% From Ft to Ft -- .'rom a Ft.to /0 Ft S-4 ai Q ! G.(.9✓05L From Ft to Ft :rom /D Ft.to ad- Ft s'A"'' 64.4✓=e From Ft to Ft from Ft to Ft CC6I 7)7 J err: <9 From Ft to Ft ''rom c)er Ft. to 4 Ft. s/< r `ra-Q.0 .SS/ From Et to Ft :'rom Ft. to Ft. 644✓ei L From Et to Ft .'rom'9'7 0 Ft te//1 Ft V t-ue Cc/47 From Ft to Ft 'rom 1/7 Ft to /a.i Ft SAw,O S! e.F'A✓cel•From Ft to Ft "rom / r)2 Ft to P11 Ft Ste/n.)0 64,114.)674. Froni Ft.to Ft :'rom Ft to Ft C &A' & '= AL From Ft to Ft From Ft to Ft From Ft. to Ft rom Ft.to ' Ft From Ft to Ft . :rom Ft. to Ft. From Ft. to Ft From Ft. to Ft. From Ft to Ft. :Tom Ft. to Ft Front Ft to Ft :'rom Ft to Ft. From Ft. to Ft. 'rom Ft to Ft. From Ft to Ft SISCL. INFORMATION: 1 DRILLER'S NAMEP MUNICICRLIT'r or Rt-7C1-, r noe DEPARTMENT OV HEALTH AND ENVIRONMENTAL PROTECTION 825 'L' STREET. ANCHORAGE, AK. 99501 264-4720 WELL P E R M I "1 - PERMIT PERMIT N0. ( 820910 ) APPLICANT SHORT CONSTRUCTION PO BOX 8AE 694-4994 LOCATION LEGAL "L7 81 TONGESS ESTATES LOT SIZE 999999 SQUARE FEET MINIMUM DISTANCE BETWEEN R WELL AND ANY ON-SITE SEWAGE DISPOSAL SYSTEM I5 100 FEET FOR A PRIVATE WELL OR 150 TO 200 FEET FROM A PUBLIC WELL DEPENDING i UPON THE TYPE OF PUBLIC WELL. MINIMUM DISTANCE FROM A PRIVATE WELL TO A PRIVATE SEWER LINE IS 25 FEET AND TO A COMMUNITY SEWER LINE IS 75 FEET. WELL LOGS ARE REQUIRED AND MUST BE RETURNED TO THE DEPARTMENT WITHIN 30 DAYS OF THE WELL COMPLETION. OTHER REQUIREMENTS MAY APPLY. SPECIFICATIONS AND CONSTRUCTION DIAGRAMS ARE AVAILABLE TO INSURE PROPER INSTALLATION. PERMIT EXPIRES 17ECEME3ER 31.. 3952 I CERTIFY THAT 1: I AM FAMILIAR WITH THE REQUIREMENTS FOR ON-SITE SEWERS AND WELLS AS SET FORTH BY THE MUNICIPALITY OF ANCHORAGE. 2: I WILL INSTALL THE SYSTEM IN ACCORDANCE WITH THE CODES. SIGNED: APPLICANT SHORT CONSTRUCTION ISSUED BYag DATE y�/��. V4.0 MUNICIPALITY OF ANCHORAGE DEPARTMENT OF HEALTH & HUMAN SERVICES Division of Environmental Services On -Site Services Section P.O. Box 196650 Anchorage, Alaska 99519-6650 343-4744 CERTIFICATE OF HEALTH AUTHORITY APPROVAL FOR A SINGLE FAMILY DWELLING Parcel I D # (1;1 — 9:2) - 1 1 1. GENERAL INFORMATION Complete legal description HAA# 1.iOPY21r1P.°12-) Lot 7; Block 1; TonJe6e Estates Location (site address or directions) 24821 32.46 Lee Count ChugLak. aK Property owner Lance CLu,(4 Day phone (W) 263-5244 (h) 688-6421 Mailing address 24821 Jesse Lev Count Chug-i.ah. AK 99567 Lending agency Day phone Mailing address Agent Day phone Address Unless otherwise requested, HAA will be held for pickup. 2. NUMBER OF BEDROOMS: 3. TYPE OF WATER SUPPLY: Individual well Community well Public water 3 XXX NOTE: If community well system, provide written confirmation from State ADEC attest- ing to the legality and status of system. 4. TYPE OF WASTEWATER DISPOSAL: Individual on-site Holding tank Community on-site Public sewer NOTE: If community wastewater system, provide written confirmation from State ADEC attesting to the legality and status of system. 12-025 (Rev. 1/91) Front MOA 121 5. STATEMENT OF INSPECTION BY ENGINEER As certified by my seal affixed hereto and as of the validation date shown below, I verify that my investigation of this Health Authority Approval application shows that the on-site water supply and/or wastewater disposal system is safe, functional and adequate for the number of bedrooms and type of structure indicated herein. I further verify that based on the information obtained from the Municipality of Anchorage files and from my investigation and inspection, the on-site water supply and/or wastewater disposal system is in compliance with all Municipal and State codes, ordinances, and regulations in effect on the date of this inspection. Name of Firm b & s Ci i0if it..^:$ING Address 17034 Eagle Rtvax nop R^;d No. Eagle River, Alaska 99577 Engineer's signature Phone 694f-2979 Date 677/9.--s° „��-Da•0yty p rn :..eta « : w...i:` PX0 bill A. • a "' 4~ 6. DHHS SIGNATURE '�' �`' —f\ Approved for 3 bedrooms. Disapproved. Conditional approval for bedrooms, with the following stipulations: Additional Comments By: Ir Date 6/74 CAUTION The Municipality of Anchorage Department of Health and Human Services (DHHS) issues Health Authority Approval Certificates based only upon the representations given in paragraph 5 above by an independent professional engineer registered in the State of Alaska. The DHHS does this as a courtesy to purchasers of homes and their lending institutions in order to satisfy certain federal and state requirements. Employees of DHHS do not conduct inspections or analyze data before a certificate is issued. The Municipality of Anchorage is not respons;ole for errors or omissions in the professional engineer's work. 72-025 (Rar,1/91)_ Batt MOA m Municipality of Anchorage Department of Health & Human Services HEALTH AUTHORITY APPROVAL CHECKLIST Legal Description: i -'c'1 ¶1.4-t -‘21,,3SE95 E•r, Parcel I D A. WELL DATA 1 Well type�E^v ^ce 'iIf A, B, or C, attach ADEC letter. ADEC water system number `A Log present 6/N) 1 Date completed 1 - 6.7- Driller SJwt %/pc-, s Cased to 11-11 Casing height ti -1\ Total depth 11-11 Sanitary seal 6,/N) Date of test Static water level Well flow Pump level y FROM WELL LOG - en - Wires properly protected pm) 4° gpm AT INSPECTION Lo -8-`13r "9.4 4- u11- oV- SEPARATION DISTANCES FROM WELL TO: t oct Septic/holding tank on lot Absorption field on lot Public sewer main Sewer service line o 4s. .1\s, ; On adjacent lots • On adjacent lots g p m z %0 c. TTt c g n In f;r1CO Cc rri w o Eg r Public sewer manhole/cleanout Petroleum tank 24S" t} WATER SAMPLE RESULTS: Coliform Nitrate 0.1c, Other bacteria O Date of sample: Lit --et5 5 & $ ENGINEERING Collected by Eagle River, Alaska 99577 B. SEPTIC/HOLDING TANK DATA Date installed 8 - Z `j -13.1- Tank size XIS° Compartments Z Cleanouts (6'/N) Y Foundation cleanout 6/N) 7 Depression (Y6 J High water alarm (WS) ''i Alarm tested (Y/N) t1^ .'v' t: •o' o.::.l .. ,. Date of pumping Pumper • .- SEPARATION DISTANCES FROM SEPTIC/HOLDING TANK TO: Well(s) on lot t o o ' On adjacent lots \ 00 14' Foundation is t 1 i- Topropertyline to 14Absorption field Water main/service line \ Ot Surface water/drainage 10 o l 72-026 (Rev. 7,91) Front CONTINUED ON BACK PAGE C. LIFT STATION Date installed Manufacturer Size in gallons Manhole/Access (Y/N) Vent (Y/N) "Pump on" level at p off" level at High water alarm level Cycles tested Meets MOA electrical cod SEPARAT on lot DISTANCE FROM LIFT STATION TO: D. ABSORPTION FIELD DATA Date installed S -Z4 -61 On adjacent Tots • Surface water Soil ratingB•' d ID F • System type PR -A-1 F' CIA) Length r' 3 ' 0 t Width C1 Gravel thickness 'y•r' t Total depth 1,5 1 Total absorption area �Sr 4 Clean -outs present STN) y Depress on over field (Y6)) IP Date of adequacy test L.- S -93 Results,(.' ail) Press for "rat -t-- (-% bedrooms - Peroxide treatment (past 12 months) (Y lXo, E- 1 -'1°d 4 If yes, give date SEPARATION DISTANCE FROM ABSORPTION FIELD TO: Well on lot Po' } On adjacent lots u o t 4- 14tt To building foundation On adjacent lots Surface water Curtain drain Property line Nov To existing or abandoned system on lot :io Cutbank all- Water main/service line I1::.3 (vot-F ala �oot1r— E. ENGINEER'S CERTIFICATION Driveway, parking/vehicle storage area'. I certify that I have check., or conformed to all MOA and HAA guidelines in effect on tlsdat9.o(this inspection. P G3 Signature O * t- �c46.,1 A. sAary : Engineer' & S GINEERING Eagle River, Alaska 99577 ,• � Nn. 14 /-1 HAA Fee $17Q`ca) Date of Payment 6. 9`?) Receipt Number 21-77$ 72-026 (Rev. 3/91) Elect MOA 21 7339 Waiver Fee•,$ Date of Payment Receipt Number r`}' 1'06%0893`;: 1 • 10:46 • CT&E'ENVIRONMENTRLLAB `SERVICES :.: :°;:EO.'064a `.:1702 • COMMERCIAL TESTING & ENGINEERINGiCO. ENVIRONMENTAL LABORATORY SERVICES .: •— Chemlab'Ref.* 193.2583-1 Client Sample ID 0,7 Bi TONJE£S EST. Matrix :WATER Client Name Ordered By Project•Name Project* PWSID, :S & S ENGINEERING :RAY SHAFER :UA REPORT of:ANALYSIStr7 5633 B STREET ANCHORAGE. AK 99516 TEL: (9071002-2343 FAR: 1707) 5615301 WORK Order -c',,-166844 Report Completed _!06/08/93 Collected •106/03/93 @ 12:30 hr: Received :06/04/93 @ 16:15 hr6 Technical DirectorsS C. EDE Released Ey :�. Sample Remarks: ROUTINE SAMPLE COLLECTED BY: RAY. Parameter QC Results Qual Units Allowable Ext. Anal Method Limits Date Date Init .Nitrate -N 0.10 U mq/L EPA 353.2/300.0 - 10 06/07 l.1.1 • • iisOitazix_zcsattftzaz=s=c=sittnuttazti=cclsitttzt zscacisittst r `" T"`SeeeSpecial.,InstrUCt�ionsrAbove`«`" ., **y1See:Sample RemarkstAbove t l r a 1 :+wnc 'U a:Undetected,;,Reported valuecisthe:practicalAquantificatio 'D`=xSecondary°dilutiori:., ..44,4,r. - c 'A. =itraaasttfttatiaaaaSSWRaaftalSat " "d" CUA`'= Unavailable. �t r.,,;., r NAie�NotiAnalyzecl�, n m•LessfEhan;-*-- 4V% 4, a GT.=.Greateri.Thanv tw 1,4,t1",711.14 +; 1 « al)" 44SGS. Member`of Iho SGS orou'ISoc4t6♦GAi6ia+e'de Suh&II r( + ,"n° ,' zJ LL P )� , + t: • :EtNIRO1iblENTACSERVICES IN,ALASKA^COLORAp.♦ UT 1141CLINOIS. OHIO MARYLAND: WEST VIRGINIA NEW JERSEY SOU H CAROLINA), t^i MUNICIPALITY OF ANCHORAGE DEPARTMENT OF HEALTH AND ENVIRONMENTAL PROTECTION DIVISION OF ENVIRONMENTAL HEALTH CERTIFICATE OF INSPECTION FOR HEALTH AUTHORITY APPROVAL 9g _ ngao OF ON-SITE SEWER AND WATER FACILITY 264-4720 Application Date 6/1/88 1. GENERAL INFORMATION (a) Legal Description (include tot, block, subdivision, section, township, range) Lot 7 Bik 1 Tonjess Estates T15NR1WSec.2 Location (address or directions) (b) Applicant Name Lynda Banner Telephone: Home N/A Business 694-5500 Applicant Address 10928 Eagle River Road Eagle River, 99577 (c) Applicant is (check one): Lending Institution ❑ ; Owner/builder 0 ; Buyer 0 ; Other &I (explain)' Pn -1t^r (d) Lending Institution N/A Telephone Address (e) Real Estate Company and Agent Jack White Company— Lynda Banner 10928 Eagle River Road Eagle River, AK 99577 Address Telephone (1) Mail the HAA to the following address: Pick—Up by Engineer 694-5500 2. TYPE OF RESIDENCE Single -Family C$ Multi -Family 0 Other Number of Bedrooms 3 i I 3. WATER SUPPLY Individual Well El Community 0 Public 0 Note: If community well system, must have written confirmation from the State Department of Environmental Conservation attesting to the legality and status. 4. SEWAGE DISPOSAL Onsite €J Public 0 Community 0 Holding Tank 0 Note: If community well system, must have written confirmation from the State Department of Environmental Conservation attesting to the legality and status. Page 1 of 2 72.025 (11i84) 5. ENGINEERING FIRM PROVIDINI...4SPECTIONS, TESTS, FILE SEARCH, DAs.. AND INFORMATION As certified by my seal affixed hereto and as of the validation date shown below, I verify that my investigation of this Health Authority Approval shows that the on-site water supply and/or wastewater disposal system is safe, functional and adequate for the number of bedrooms and type of structure indicated herein. I further verify that based on the information obtained from the Municipality of Anchorage files and from my investigation and inspection. the on-site water supply and/or wastewater disposal system is in compliance with all Municipal and State codes, ordinances, and regulations in effect on the date of this inspection. Name of Firm Eagle River Enaineerinq Serv;Wtone 907/694-5195 Address P.O. Box 773294 Eagle River. AK 99577 Date 6/1/133 Engineer's Seal .. 11 A 6. DHEP ed for 7Z �_/�4 %'"!� — !� / / `rte Approved for ,eri�bedrooms byDate / Approved v` Disapproved Conditional Terms of Conditional Approval CAUTION The Muncipality of Anchorage Department of Health and Environmental Protection (DHEP) issues Health Authority Approval certificates based solely upon the representations given in paragraph 5 above by an independent professional engineer registered in the State of Alaska. The DHEP does this as a courtesy to purchasers of homes and their lending institutions in order to satisfy certain federal and state requirements. Employees of DHEP do not conduct inspections or analyze data before a certificate is issued. The Municipality of Anchorage is not responsible for errors or omissions in the professional engineer's work. Page 2 of 2 72-025 (11184) '-.(OF'.•'"�tUNICIPALITYOFANCHORAGE(MOS..,I 11' HEALTH AUTHORITY APPROVAL (HAA) CHECKLIST - FEBRUARY 1984 30\1 1 19� 264-4720 Legal Description• ICS fa fe i A. WELL DATA ttcoo Well Classification Pet ;As ie Well Log Present (Y/N) i Date Completed Let 7 ic*-/ .n ,esr Tis .v T/w s«.Z If A, B, C, D.EC. Approved (Y/N) 7/4 - Total Depth /n Cased to �� 7 Static Water Level 6-2' Casing Height Above Ground +/'2 " Electrical Wiring in Conduit (Y/N) Depth of Grouting Separation Distances from Well: To Septic/Holding Tank on Lot */Do .074 Yield 7.tco.. 7&1e4 s-n3-sa Pump Set At t 2 ' Sanitary Seal on Casing (Y/N) i Depression Around Wellhead (Y/N) • On Adjoining Lots +/eo' To Nearest Edge of Absorption Field on Lot -Nee ' ; On Adjoining Lots *neo' To Nearest Public Sewer Line or, Cleanout/Manhole evA To Nearest Public Sewer To Nearest Sewer Service Line on Lot taS 1 Water Sample Collected by S $ r E...s'-.•e a -'.-r Water Sample Test Results Comments Co / %F+. -.-.v. Fie • Date S - /.2 - SY ill' jtre >1 = Al B. SEPTIC/HOLDING TANK DATA Date Installed IT S2 Size /1reS1 No of Compartments —Z Standpipes (Y/N) y Air -tight Caps (Y/N) ' Foundation Cleanout (Y/N) Depression over Tank (Y/N) 4' Date Last Pumped S -7t8 Pumping/Maintenance Contract on File (Y/N) ns • for -nhE Holding Tank High -Water Alarm (Y/N) Separation Distances from Septic/Holding Tank: To Water -Supply Well +100' Temporary Holding Tank Permit (Y/N) To Building Foundation 8� To Property Line � To Disposal Field i To Water Main/Service Line t /O To Stream, Pond, Lake, or Major Drainage Course i/o o' Comments Page 1 of 2 72-026(11184( C. ABSORPTION FIELD DATA Soils Rating in Absorption Strata r.5"/trR Type of System Design 4 a,+, r4 e/o( Date Installed /ft a. s'4 Width of Field Square Feet of Absorption Area Depression over Field (Y/N) Results of Last Adequacy Test N Length of Field 30 11'4 Depth of Field Gravel Bed Thickness Sa re C74.. ya "A Standpipes Present (Y/N) Y Date of Last Adequacy Test s -17 - 28 7 tie A6s..6t- -. .G se Separation Distance from Absorption Field: To Water -Supply Well -neeTo Property Line do ' To Building Foundation ao To Existing or Abandoned System on Lot NS • On Adjoining Lots f 3c To Water Main/Service Line oio # To Cutbank (if present) ^/fit To Stream/Pond/Lake/or Major Drainage Course +100 ' 1 To Driveway, Parking7re@. or Vehicle Storage Area ~7D Comments q= ! / L=3e' '0cS1 1. ..T4 1...)4...,_fa„�..e,.���r../ -12:1 - 2G 7.1 ZGA I° ,o D. LIFT STATION NA d -ii' amt re” Date Installed Dimensions Size in Gallons Manhole/Access (Y/N) "Pump On" Level at "Pump Off" Level at High Water Alarm Level at Vent (Y/N) Tested for Pumping Cycles during Adequacy Test. Meets MOA Electrical Codes (Y/N) Comments "Check Permitted Bedroom Rating Against HAA Request .. I certify that I have checked, verified, or conformed to all MOA and HAA guidelines in effect on the date of this inspection. Signed ��"'"+'^� Date 1/31/75' Company Receipt No. 1201 River Fnpinfw.y q..,m. e, MOA No. At - .245— P. 0. Bac 773294 Eaple River, AK 99577 Date of Payment 694.5195 ( r o Amount: $ 1 /7 O - 0 5 gc2.6 3 7i Page 2 of 2 72026 (1Leo) ;Jr1• rry •.'• it' •a '''.d. �; � ` •°•e v� d 11,61.1..:1447:P147-177, %-. is Fe •. Art ..... ..•N1 1'. F : LouL• A. !mora �' �, °�, A• CEa726 ".....41,„*". T !" i. �,- k 'tar 0FESSt0''t'�z' r MUNICIPALITY OF ANCHCRAGE DEPARTMENT OF HEALTH AND ENVIRONMENTAL PROTECTION DIVISION OF ENVIRONMENTAL HEALTH CERTIFICATE OF INSPECTION FOR HEALTH AUTHORITY APPROVAL OF ON-SITE SEWER AND WATER FACILITY • 264.4720 Application Date b- I9- Gb 1. GENERAL INFORMATION (a) Legal Description (include lot, block, subdivision, section, township, range) Linn- •Tft,e, fir Location (address or directions) X11 et (b) Applicant Name '&oiS Mit_-A E9 -T Telephone: Home to ee 2-0t03 Business Z?t" LCto Applicant Address sf'-7- 'P'cK 14,141+1 GtioC-.IMl- Pei-, qel 5 67 (c) Applicant is (check one): Lending Institution 0 ; Owner/builder(; Buyer 0 ; Other 0 (explain). (d) Lending Institution 'kV e. Telephone Address t,isittez ' t: (e) Real Estate Company and Agent 14 o. -I QlOri Address Telephone (f) Mail the HAA to the following address: 54 5 ENGINEERING -SR 8 196X _____EAGLER1VER,..6.1C99577 2. TYPE OF RESIDENCE Single -Family,- Multi -Family ❑ Other Number of Bedrooms 3 3. WATER SUPPLY Individual Well 0- Community 0 Public 0 Note: If community well system, must have written confirmation from the State Department of Environmental Conservation attesting to the legality and status. 4. SEWAGE DISPOSAL Onsite.T- Public 0 Community 0 Holding Tank 0 Note: If community well system, must have written confirmation from the State Department of Environmental Conservation attesting to the legality and status. Page 1 of 2 72-025 n 1/84) (12.1 5. ENGINEERING FIRM PROVIDING ..4SPECTIONS, TESTS, FILE SEARCH, DM.. AND INFORMATION • As certified by my seal affixed hereto and as of the validation date shown below, I verify that my investigation of this Health Authority Approval shows that the on-site water supply and/or wastewater disposal system is safe, functional and adequate for the number of bedrooms and type of structure Indicated herein. I further verify that based on the information obtained from the Municipality of Anchorage files and from my investigation and inspection, the on-site water supply and/or wastewater disposal system is In compliance with all Municipal and State codes, ordinances, and regulations in effect on the date of this inspection. S & S ENGINEERING Name of Firm —SR B 196X Telephone Address EAGLERIVER, AK 99577 Date 6. DHEP APPROVAL Approved for ..17/441 -)bedrooms by Approved •Disapproved Date / �� Conditio al Terms of Conditional Approval CAUTION The Muncipality of Anchorage Department of Health and Environmental Protection (DHEP) issues Health Authority Approval certificates based solely upon the representations given In paragraph 5 above by an independent professional engineer registered in the State of Alaska. The DHEP does this as a courtesy to purchasers of homes and their lending institutions In order to satisfy certain federal and state requirements. Employees of DHEP do not conduct Inspections or analyze data before a certificate is Issued. The Municipality of Anchorage is not responsible for errors or omissions in the professional engineer's work. Page 2 of 2 72-025 711/81) A. WELL DATA Well Classification n S,F MUNICIPALITY OF ANCHORAGZ DEPT. OF HEALTH g, MUNICIPALITY OF ANCHORAGE (MOA) ENVIRONMENTAL PROTECTION HEALTH AUTHORITY APPROVAL (HAA) CHECKLIST - FEBRUARY 1984 '71986 264-4720 6[� Q' Legal Description. LI" rR FGE+V E D Tont ,s trf Well Log PresentQ$)N) • Total Depth X24 , 9 Static Water Level Cased to SO If A, B, C, D.E.C. Approved (Y/N) Alp Date Completed 7/g=- Yield o•5-4Or^ -1— r • y 1-4..V Depth of Grouting Casing Height Above Ground Electrical Wiring in ConduitaN) Separation Distances from Well: To Septic/HeldiTTank on Lot re" (ov r To Nearest Edge of Absorption Field on Lot To Nearest Public Sewer Line a1A Cleanout/Manhole /b Water Sample Collected by Pump Set At Og Sanitary Seal on Casing 4P/N) • Depression Around Wellhead (Y/QI l ao I -I - Water Sample Test Results Comments • On Adjoining Lots lao • On Adjoining Lots .>Do 1'1" To Nearest Public Sewer To Nearest Sewer Service Line on Lot S%S •Date Sans 6 -19 Vie r -t. /iesl-c TL'Sr ezteertoeco D.SGfir B. SEPTIC/H9tDIRG TANK DATA Date Installed e-7-4 --e t Size 1 'T No of Compartments Z - Standpipes CAN) Air -tight Caps ON) Depression over Tank (Y.(6? Date Last Pumped Pumping/Maintenance Contract on File (Y/N)f' •for Holding Tank High -Water Alarm (Y/N) ' I Temporary Holding Tank Permit (Y/N) Separation Distances from Septiclding-Tank: To Water -Supply Well l 00r et Foundation Cleanout (JN) to -to - $b To Property Line l u lora To Water Main/Service Line aA Course To Building Foundation To Disposal Field S To Stream, Pond, Lake, or Major Drainage Comments Page 1 of 2 72-026(11/84) ( C. ABSORPTION FIELD DATA Soils Rating in Absorption Strata e:54' 164-- Type of System Design 1711--- r r tltn A Date Installed Width of Field -- ?-'-r -8y icon- 1.1"' oo r t• - Square Feet of Absorption Area Depression over Field (Y/67 Results of Last Adequacy Test 25 S Length of Field Depth of Field 1 1/1-1 Gravel Bed Thickness • re t 0 Standpipes Present (tN) Date of Last Adequacy Test S/ t —3 e'rL_ to -t -t —ate' Separation Distance from Absorption Field: To Water -Supply Well 1 Oo IA- To Property Line To Building Foundation 14'r Lot 111 4 To Water Main/Service Line l o tl– • On Adjoining Lots To Stream/Pond/Lake/or Major Drainage Course To Driveway. Parking Area. or Vehicle Storage Area Comments 0 1* To Existing or Abandoned System on 3o I-1- a To Cutbank (if present) A/he too r.t� D. LIFT STATION Date Installed Dimensions Size in Gallons Manhole/Access (Y/N) "Pump On" Level at" �A "Pump Off' Level at High Water Alarm Level at / ' Vent (Y/N) Tested for Pumping Cycles during Adequacy Test. Meets MOA - Electrical Codes (Y/N) Comments " Check Permitted Bedroom Rating Against HAA Request •. I certify that 1 have checked, verified. or conformed to all MOA and SignedS & S ENGINEERING SR B 196X Compares MOA No. ary --cam tAGIE RIVER, AK 99577 0 3' Receipt No 3 9 0 7a to Date of Payment 6 -97' 86 HAA guidelines in effect on the date of this inspection. Date JU 2 6 ISCB Amount: $ �op Page 2 of 2 72-026 (11,84) OF AC,;1 i�F1i71inaar'c gafYC �_ * %' ties 14674 47 at: - APPLICNT FILLS OUT UPPER HAh ONLY Property Owner &Ade L. C. 7....C..//9 ne y/ Mailing Address s/. ,1) 1�pc (- ': G//,9 I< , I) Zip Code Phone "�� �/ neS/• (/9�T�1'� y Buyer o Q. t Oe icicle {- T Address CV.,/u, ' A K ,4 X Zip Code Lending Institution ! �1.R �"9�i - - -. r;,e.ST LW !9 5XII y.1 Address EA 9 [ p j . t ✓P /L Zip Code Phone - - Realty Co. & Agent C . 2 / /'@ b,. 14ye //D.n,es Address frig le ,P; s -p /(._ Zip Code Phone Legal Description 7 2 7 3 / TO .Ji --e cS TTypeStreet Location CC Cte LP e Cr- Typeof Residence 4 Single Family O Multiple Family No. of Bedrooms Date ❑ Other Water Supply ❑ Individual ❑ Community ❑ Public Utility ATTACH WELL LOG. A well log Is required for all wells drilled since June 1975. For wells trilled prior to that date, give well depth (attach log 0 available). Sewer Disposal O Individual ❑ Public Utility ❑ Holding Tank , Year Individual Installed: When Connected to Public Utility. Inspector NOTE: THE INSPECTION FEE MUST ACCOMPANY EACH REQUEST BEFORE PROCESSING CAN BE INITIATED. -, Time Time Time Time Date Date Date Date Inspector Inspector InsD:tor Inspector Field Notes: EN ERT. C OF ANCHORAOE ENVIROA,7vt CF L: -TH A �r`1TAL PROTECTION OCT 6 L ,, RECEIVED (3) APPROVED BEDROOMS ( ) DISAPPROVED ( ) CONDIT NALAPPROVAL' DATEia �'/ 3 'CONDITIONS OF APPROVAL BY - Soils Rating Date Sewer Installed Well To Absorption Area Well to Tank Well Log Received Septic Tank Size 72423 IYatl S & S Engineering SRB 196X Eagle River, Alaska 99577 October 3, 1983 Earl Chappell Star Route Box 126 Eagle River, Alaska 99577 Dear Mr. Chappell, Reference: Lot 7; Block 1; Tongass Estates A well and septic approval requested on this property resulted in -have the septic tank pumped and verifying its capacity to be 1000 gallons. The well casing was inspected and found to be equipped with an adequate sanitary seal and all well wires had been placed in conduit. The earth around the well casing was adequately sloped away from the well. A water sample was taken from the kitchen sink and submitted to Chemical and Geological Laboratories of Alaska for total coliform bacteria analysis. The results of this test were satisfactory. If we may be of further service to you, please do not hesitate tb contact us. Sin ERT A. H FER, P.E. /ss Municipality of Anchorage Department of Health and Environmental Protection 'iA"��+•,en�. �L {.T.! VN..ase APPLIrNT FILLS OUT UPPER HAL'ONLY Zip Code Phone Praperty Owner co H r S N 0-p-7 .. C ME. ailing Address PC 3 0 1 g A ' Buyer C H)9 PPe t L Address 70 '-i O ID r Ckeiestra bk Zip Code 4PS0 V Lending Institution • /1L195/!q 07vrQ1/l l &A PC Address Zip Code Phone ,n Realty Co.& Agent CeAo7toRy '/ NANCO P' Fell Lty 67-N A veZip Code Address 4O i E. Phone �5' Legal Description I O / T / %3 L i< 1 / l V y Street Location _ T e S S co C T Inspector Inspector dd,� MUNICIPAMfi' w ANICHf)RAf;E .. /•// JT Q S s i [-- -�+ Zi- Type of Residence .s Single Family ❑ Multiple Family No. of Bedrooms 1CrLLL1 1 ❑ Other /L1'1 Water Supply Olab , V&1 1J 1 (fit • C) J•-LII ATTACH WELL LOG. A well log Is required for all wells drilled since June 1975. For wells drilled prior to that date, give well depth (attach log if available). ...im Individual ❑ Community r • D [a. ❑ Public Utility Sewer Disposal .g Individual ❑ Public Utility ❑ Holding Tank C v� Year Individual Installed. / O d / When Comected 10 Public Utility. Septic Tank Size 1 Z S"U NOTE: THE INSPECTION FEE MUST ACCOMPANY EACH REQUEST BEFORE PROCESSING CAN BE INITIATED. Time Time Time Time Cir Aiczd P 4"t0 Date Date Date Date q-1 LI- 91(11 LCS Inspector Inspector Inspector Inspector dd,� MUNICIPAMfi' w ANICHf)RAf;E ` 1 ,r Field Notes: O ' LV QO // Cf>T .r I . ; .0 ". -L-I2-0 ,/rms/ ENVIF.�g.'.a:.a.!.OE.;I_.� T 5 A f SEP 81982 RECEIVED (3) APPROVED BEDROOMS ( ) DISAPPROVED ( ) CONDITIONAL�APPROVAL' DATE / �it.�{/ - 'CONDITIONS OF APPROVAL P BY: �L�/ Soils Rating Dale Sewer Installed Q- Q.t.- Well To Absorption Area Well to Tank Weil Log Received I O Septic Tank Size 1 Z S"U 72423 ball