HomeMy WebLinkAboutEAGLE RIVER VALLEY RANCHETTES LT 16D ~ MUNICIPALITY OF ANCHORAGE ~ '' D[ RTMENT OF HEALTH AND HUMAN SEF~ES · Environmental Health Division 825 "L" Street. Anchorage, Alaska 99502. Telephone 264-4720 ON-SITE SEWAGE DISPOSAL SYSTEM AND/OR WELL INSPECTION REPORT N~m. DISTANCES ~5~t~// /22/~'~"~ ~ SEPTIC ABSOBPTION ~'~ TANK FIELD WELL I TANKS KI ~ ~EPTIC ~ HOLDING / TYPE OF GYSTEM ~ TRENCH ~ BED ~ W. DRAIN ~ OTHER , ~ ~ FT /~ FT WELLS = ~ PRIVATE ~OTHER Ildentifv) REMARKS: 72-013 DEPARTMENT OF HEALTH AND ENVIRONMENTAL PROTECTION 825 L STREET, ANCHORAGE, AK 99501 264-4720 ON--SITE SEWER PERMIT PERMIT NO: DATE ISSUED: 850629 HAND WRITTEN 09/26/85 APPLiCANl: ADDRESS: CONTACT PHONE: BILL MIKAWA 70 MAN OF WAR EAGLE RIVER~ AK 694-9661 99577 LEGAL DESCRIP: LOT SIZE: SUBDIVISION: E.R.VALLEY RANCHETTE LOT: I&D SECTION: 7 ~OWNSHIP: 14N RANGE: 1W 0.5A . (SQ.FT. OR ACRES) BLOCK: NA certify that: 1. I am familiar with the requirements For 2. on-site sewers and wells as'set forth by the Municipality of Anchorage (MOA) and the State of Alaska. I will install the system in accordance with all MOA codes and regulations, and in compliance with the design criteria or this permit. I will adhere to all MOA and State or Alaska requirements For the set back distances from any existing well, wastewater disposal system or public sewerage system on this or any adjacent or nearby lot. IF A THEN WILL ELECTRICAL WORK MUST BE DONE BY A LICENSED ELECTRICIAN. LIFT STATION IS INSTALLED IN AN AREA COVERED BY MOA BUILDING CODES, (1) AN ELECTRICAL PERMIT AND INSPECTION MUST BE OBTAINED; (2) AS-BUILTS THE NOT BE APPROVED WITHOUT AN E~_ECTRICAL INSPECTION REPORT; AND (5) DATE: SIGNED __~_ ~_-_ _~_ _ ___~_ .... - ..... APPLICANT: BILL MIKAWA DATE: · EAGLE RIVEr( .~o. ,~Z~ 7*' /~, ' ~ · ENGINEERING SERVICES INC. ' ; '" P.O. Box 773294 %* ' EAGLE RIVER, ALASKA 99577 C^~.CU~.^T£D e¥ · Phone 694-5195 ri EAGLE RIVER ENGINEERING SERVICES INC. P. O. Box 773294 EAGLE RIVER. A~SKA 99577 CALCU~ATEO BY ", , Phone 694-5195 · ,' CHECKED BY DAT~ LEGAL DESCRIPTION: ,~.~' /~ 6- ' ('~q~ " ~ ,~ SOILS LOG MUNICIPALITY OF ANCHOI~AG£ DEPARTMENT OF HEALTH AND ENVIRONMENTAL PROTECTION PERCOLATION ... TEST 825 L. St, rear. Anchorage, Alask~ gaS01 2844720 · " SOILS LOG -- PERCOLATION TEST II Ill III · II1.. ,.ILl I1~1 I1~1 I1,~ III 8 9 10 11 12 14- WAS GROUND WATER /*~,/O ~. ~o E ENCOUNTERED? IF YES, ATWHAT DEPTH? : - ~'H~/e Gross Net Depth to Net Read;ng Date Time Time Water Drop I I' .A':/~ i/"...,,.;' ~/;~ '//,' .I ~" PERCOLATION RATE ~" '~ (minutes/inch) '/~ '~ ~/~"~ . ?~.ooa tenD) · ~ - ~- MUNICIPALITY OF ANCHORAGE . . DEPARTMENT OF HEALTH & ENVIRONMENTAL PROTECTION I ENGINEERING DIVISION ENVIRONMENTAL 825 L Street - A~cho~age, Alaska 99501 Telephoee 2644720 ON-SITE SEWAGE DISPOSAL SYSTEM AND/OR WELL INSPECTION REPORT NAME ,- _~ PHONE · I I-~ NEW MA,L, NGADORESS /: O --/,:'~-' ¥ "-' - ' '__ LEGAL DESCRIPTION LOCATION NO. OF BEDROOMS ,,'- I ~ ~ Manuf~turer No. of compartments Liq. capacity in gallons Inside length Width Liquid depth ?.'~.~ /,~; %~ /:,Z~ f IFHOME~DE: . _ ~ ~-- ~ ~ DISTANCE ~O; Well // Dwelling PERMIT NO. a=z ,,~ ~/./ ~ ~ ~ Manufacturer Material Liquid capacity in = We.~/~ Foundation ~ Noarestlothne ~/ , PERMI~,O. , ~ ~ ~ No. of lin~ / Length of e~h rne-- Total leng~ o~ines -- Trench wJdt~/ Distance ~t~en lines --Zm , [~ ~ ~/- ~- ~ ~/- _~ inches ~ / /7 ~ ~ ~ Top of tile to finish gra~ Total eff~iw ~orptlon,area ~--~/~(/[~1~-~ Material beneath tile Length W;dth ~th PERMIT ~./~  Type of crib Crib diameter C~ib depth / Total eff~ti~ a~o~ption area / / ~ / , ,, m Well Building foun~tion Nearer lot line m DISTANCE TO: /t~ ~ /// ~.~T~ & ~,~ J ~ CI~s / / / ~ Depth Driller : Distance to lot line PERMIT NO. ~ DISTANCE TO: Building foundation J ~ ' _~ ~ptic tank Absorption areaJs) OTHER ~,~_,-... , .. I .'~,~ SOILTEST RATING ~ / ~/~ ~ ................ ~ L~t:L Jn~-: ~ ~..'..- , ..'. j ' ,:~ ;r;,.dsr ) · z . '-- 72-013 (Rev. 3~78) PERMIT NO. r~U[4 I 6 It'~RL I T¥ OF Rr4CF~.RRGE DEPARTMENT Or' HEALTH AND ENVIRONMENTAL ~--ROTECTION '825 ~L~ STREET, RNCHORRGE~ AK. 264-472~ Of4--S I Ti 781815 ) SEWER LIPGRRDE PEAr, IT APPLICANT LOCATION LEGAL MELVIN STEWART PO BOX EAGLE RIVER RRNCHETTES LIGD EAGLE RIVER RRNCHETTES LOT SIZE 694 9594 iBC00 SQUARE PEET TYPE OF SOIL RBSORBTION SYSTEM IS: TRENCH MAXIMUM N~JMBER OF BEDROOMS = 4 SOIL RATING THE REQUIRED SIZE OF THE SOIL ABSORPTION SYSTEM IS: DEPTH= 8 LENGTH= ~;:4 GRFIVEL DEPTH= THE LENGTH DIMENSION IS THE LENGTH (IN PEET) OF THE TRENCH OR DRAINFIELD. THE DEPTH OF A TRENCH OR PIT IS THE DISTANCE BETWEEN THE SURFACE OF THE GROUND AND THE BOTTOM OF THE EXCAVATION (IN FEET). THERE IS NO SET WIDTH FOR TRENCHES. THE GRAVEL DEPTH IS THE MINIMUM DEPTH OF GRAVEL BETWEEN THE OUTFALL PIPE AND THE BOTTOM OF THE EXCAVATION (IN FEET>. PERMIT APPLICANT HAS THE RESPONSIBILITY TO INFORM THIS DEPARTMENT DURING THE INSTALLATIOH INSPECTIONS OP ANY WELLS ADJACENT TO THIS PROPERTY ANC~ THE NUMBER OF RESIDENCES THAT THE WELL WILL SERVE. T&40 (2) I f4SPECT IONS ARE REQU I RED BACKFILLING OF ANY SYSTEM WITHOUT PINAL INSPECTION AND APPROVAL BY THIS DEPARTMENT WILL BE SUBJECT TO PROSECUTION. MINIMUM DISTANCE BETWEEN A WELL AND ANY ON-SITE SEWAGE DISPOSAL SYSTEM IS i00 PEET POP A PRIVATE WELL; OR 150 TO 200 PEET FROM A PUBLIC WELL DEPENDING UPON THE TYPE OF PUBLIC WELL. OTHER REQUIREMENTS MAY APPLY. SPECIFICATIONS AND CONSTRUCTION DIAGRAMS ARE AVAILABLE TO INSURE PROPER INSTALLATION. PERM I T EXP I RES DECEMBER ..~2-- I CERTIPY THAT l: I AM FAMILIAR WITH THE REQUIREMENTS FOR ON-SITE SEWERS AND WELLS AS SET PORTH BY THE MUNICIPALITY OF ANCHORAGE. · 2: I WILL INSTALL THE SYSTEM IN ACCORDANCE WITH THE CODES. ~: I UNBERSTR~? T~T~HE ON-SITE SEWER SYSTEM MAY REQUIRE ENLARGEMENT IF THE RESIDENCE IS ~~ TO~NC~DE MORE THAN 4 BEDROOMS. SOILS LOG MUNICIPALITY OF ANCHORAGE DEPARTMENT OF HEALTH AND ENVIRONMENTAL PROTECTION Pouch 6.65~, Am~o~, Ala~a 99602 276-2221 SOILS LOG -- PERCOLATION TEST PERCOLATION TEST PERFORMED FOR: 1 2 3 4 5 6 7 8 9- 10- 11 13- SLOPE SITE PLAN 'Reading ' Date GrossNet Depth to Net Time TimeWaterDrop / 21&~- 3,'~?, gl .z ,, 4:2o?~,~t,, ~y~ z ~ " ~ ,, 4:~oe~o,,,:. ~& 15 16 17 18 19 PERCOLATION RATE TEST RUN BETWEEN *~'~ FT AND ~, FT · 4'/m [~ LTl i._l_...l___] Muwcipwityrkachorage an -Silk" Water and wa$tewato M (907).343-7,904 Certificate of -Sy On -8-i t, e .Ster6s. Approval Parcel I.D. o5o.222.11 -EXPiration Date: 1. GENERAL INFORMATION: Complete legal description - EAGLE RIVPP-VALLEY p, '0H —ET--T—ESL—01- I 6D Location (site address) 18627 MAN 0 WAR ROAn PMl = OR/CM Ab, Current Property owner(S) . PATRIQ<MAPTlKl;:.ij?, I AJIMjl3gZ,� DAy phone 111-1270 Mailing addrett 18627 MAN Ovyap PnAnk EAGLE GLE RIVER AK 99577 Real Estate Agent WENDY RRIMr,'Wi mtrr Day phone 114-1236 2. TYPE OF DWELLINGO Z Single Family (w/wo ADU) 0 Duplex 0 Multiple Dwellings (Single Family and/or Duplex). 3. NUMBER OF BEDROOMS.- 4 4. TYPE OF WATER StjppLy- TYPE OFWASTEWATER DISPOSAL: Individual Well Individual Individual Water Sto rage EJ Holding Tank Community Class _ Well Q Community Public Water System Public Sewer WaiverNaftnce request fo —Distance,.__. Received by: Date! COSA to be released to the engineer, unless otherwise recluested by theengineer. COSA Fee :River l=ee' $ Date of Payment, Date bf'Payment. , , Receipt 'Number — Q -574q,97 Receipt Number t1A0 COSA # wlt;0Waiver # 1- 1. 25% DISCOUNT APPLE'. 5. STATEMENT OF INSPECTION BY ENGINEER As certified by my sea[ affixed hereto and as of the validation date shown below, I verify that my investigation, based on procedures outlined in the Certificate of On -Site Systems Approval Guidelines for this application, shows that the on-site water supply and/or wastewater disposal system is (are) safe, functional and adequate for the number of bedrooms and type of structure indicated herein. I further verify that based on the information obtained from the Municipality of Anchorage files and from my investigation and inspection, the on-site water supply and/or wastewater disposal system is(are) in compliance with all applicable Municipal and State codes, ordinances, and regulations in effect at the time of installation. Name of Firm: Garness Engineering Group, Ltd (GEG) Phone: 907-337-6179 Address: 3701 East Tudor Road, Suite 101- Anchorage, Alaska 99507 Engineer's Printed Name: Jeffrey A. Garness Date: 7.0 In conducting this evaluation, GEG provided an engineering evaluation of the well and/or septic system in accordance with the guidelines and regulations established by the Municipality of Anchorage and industry practices. The reported results describe the condition of the systern/s on the date/s of the evaluation. Separation distances were measured to readily identifiable features. Hidden defects or encroachments may exist that were not identified during the evaluation. The operational life of all wells and septic systems depend upon a variety of variables, including but not limited to, soil conditions, groundwater levels (that may fluctuate during the year), quality of construction (materials and workmanship), and the water usage of the family utilizing the system/s. These conditions can vary, and are outside the control of GEG. Satisfactory test results do not guarantee future performance of the system/s; therefore, GEG makes no warranty (express or implied) regarding the future performance of the well or septic system. GEG makes no representation whether an alternative well or septic system can be installed on the property in the event either of the current systems fail to perform adequately in the future. The content of this report is for the sole benefit of the person/party that retained GEG to perform the evaluation. Reliance upon the information provided in this report by any other person or party (including subsequent property purchasers) is not authorized, nor will it confer any legal right whatsoever. 6. DSD SIGNATURE x System #1 Approved for q bedrooms System #2 Approved for Disapproved Conditional approval for o ��..0• 54 ..Vorn ss,:... 5 Ce,,l L) Z c o f e s sio�°- #AECC884 bedrooms _ bedrooms, with the fo!{owing'r :tioN_SITE �AL EtfND <- wAST�V�IF� . i3Y ����aut,5vOriginal Certificate Date: .Q0,2 Q The Municipality of Anchorage Development Services Division (DSD) issues certificates of On -Site Systems Approval (COSA) based only upon the representations given in paragraph 5 by an independent professional civil engineer registered in the State of Alaska. The Municipality of Anchorage is not responsible for errors or omissions in the professional engineer's work. 7. ATTACHMENTS: COSA Checklist_ Nitrate Advisory Septic System Advisory Arsenic Advisory Well Flow Advisory Other COSA blue sheet_10.10.12.doc J�5-�� s;J6 /?-D COSA Checklist Legal Description: EAGLE RIVER VALLEY RANCHETTES; LOT 16D Parcel ID: 050-222-11 If more than 1 septic system on lot: COSA Checklist # 1 of 1 Structure served by this system 1 DATA AWWU WATER ❑ Well log I with Onsite (or attached) Date drilled Total depth ft Cased to ft ❑ Sanitary seal is functioning correctly ❑ Wires are properly protected Casing height (above ground) in. Date of flow test for C Stat;me Ovate eat beginning of test ft. nts Well production at time of test Water storage tank volu gallons Well disinfecte coliform test? ❑ Yes ❑■ No orm bacteria is Negative Nitrate mg/L ❑ Nitrate less than MRL (ND) Ars ug/L ❑ Arsenic less than MRL (ND) Collected by Date of Sample B. TANK DATA >station N Age of tank(s) 5 years intenance com Tank type/material STEEL n y Measured operating fluid level in septic tank 48.75" ria❑■ Standpipes/foundation cleanout per record drawing Date of pumping 8/5/2019 D. ABSORPTION FIELD DATA *2003 BED Which system tested (date installed) 5/3/2003 Adequacy test date ❑■ ALL standpipes present per record drawing Results Q✓ Pass For 4 bedrooms Total measured depth from grade 3.75 ft (max) Fluid depth prior to test ***0 in Measured depth to pipe invert from grade 2.88 ft (min) Water added 898 gal ❑ N/A — pressurized field ***0.75 New depth In 0 Monitor tubes go to bottom of effective. If not, state 156 depth into effective Elapsed time min FEWCode-requiredsoil cover over field Final fluid depth ***0 in ❑■ System presoaked Absorption rate 600+ gpd (Required if vacant for greater than 30 days prior to Any rejuvenation treatment (past 12 months) NONE date of test) Gallons introduced *2003 gallons If yes, enter date Comments/Deficiencies: *ADDED 336 GALLONS ON 4/21/20 AND 1667 GALLON ON 4/22/20. RECEIVED VERBAL FROM TIM EKLUND ON 4/21/20 AND HE APPROVED PRESOAK METHOD. ALSO PRSOAKED AND TESTED 1985 BED DRAINFIELD ON 4/27/2020 (SEE ATTACHED REPORT). **ADDED WATER TO MIDDLE CLEANOUT ON NORTHEND OF TRENCH. ***IN NORTHWEST MT 0.5" OF L.L. IN NORTHEAST MT AND SOUTH MT'S REMIANED DRY THROUGHOUT TEST. COSA Checklist yellow sheet E. SEPARATION DISTANCES AWWU WATER ivate Well on Lot to: (Please enter distances if less than required or if community well) Septic Tank/Lift Sta Lot > 100' ❑ Yes Community Sewer Manhol out > 100' Yes if No ft ❑ Yes if No ft Neighboring Tank > 100' ❑ Yes if No ft P ' ewer/Septic -Line > 25' ❑ Yes if No ft Absorption Field on Lot > 100' ❑ Yes if No Tank > 100' ❑ Yes if No ft Neighboring Absorption Fields > Private Wells > 100' Animal Containme _ 0' ❑ Yes if No ft ❑ Yes if No ft ft Community Wells > 200'✓❑ Yes if No ft Water Service Line > 10' Manure/Animal Excreta Storage > if No Co y Sewer Main > 75' ❑ Yes if No ft 0 Yes if ft From Septic/Holding Tank on Lot to: (Please enter distances if less than required) Building Foundations > 10' ❑ Yes if No ft Surface Water > 100' Q Yes if No ft Property Line > 5' ❑✓ Yes if No ft Wells on Adjacent Lots: Yes Absorption Field > 5' ❑✓ Yes if No ft Private Wells > 100' ❑✓ Yes if No ft Water Main > 10' ❑✓ Yes if No ft Community Wells > 200'✓❑ Yes if No ft Water Service Line > 10' ✓❑ Yes if No ft If septic tank is under driveway comment below From Absorption Field on Lot to: (Please enter distances if less than required) Building Foundation > 10' ❑ Yes if No **4 ft If absorption field is under driveway comment below Property Line > 10' ❑ Yes if No ft Wells on Adjacent Lots: Water Main > 10'✓❑ Yes if No ft Private Wells > 100' Q Yes if No ft Water Service Line > 10' ❑✓ Yes if No ft Community Wells > 200' ❑✓ Yes if No ft Surface Water > 100'✓❑ Yes if No ft F. ENGINEER'S COMMENTS 'TANK INSTALLED 2015. CURRENT MEASUREMENT FROM CENTER OF ST1 TO EDGE OF FOUNDATION IS 71" WITH PIPE SLIGHTLY LEANING TOWARDS FOUNDATION —SEE WAIVER #OSP141394. -SEE WAIVER # WR030057. *-PER 2003 ROBERT COWEN, P.E. INSEPCTION REPORT - GEG DO NOT VERY SEPRATION DISTANCE. NOTE: 4'-6' CUTBANK @ WEST PROPERTY LINE LINE. NO INIDCATION OF SURFACING EFFLUENT AT BASE OF NEIGHBOR'S DRIVEWAY. NOTE: UPDATED 2020 AS -BUILT SURVEY IS MISSING CO/MT IN SOUTHEAST CORNER OF 2003 BED. THESE PIPES WERE OBSERVED WHILE ONSITE AND THE 2006 SURVEY (FROM THE SAME SURVEYOR) ON FILE AT MOA SHOWS THESE PIPES ARE THERE. _QQ600p G. ENGINEER'S CERTIFICATION _� F �QQ I certify that 1 have determined through field inspections and review of Municipal records that the above systems are /n conformance withQO MOA COSH guidelines in effect on this date. �a 4 H ,,. . Qn ff Garn ss:' E— 20��0� COSA Checklist yellow sheet 00 r f esS�0�G o� #AECC884 May 6, 2020 Municipality of Anchorage Development Services On -Site Water & Wastewater Program 4700 Elmore Road Anchorage, Alaska 99507 Phone: (907) 343-7904 Attention: Tim Eklund Reference: Explanation Letter of Septic Adequacy Test and Septic System Elevations for Eagle River Valley Ranchettes; Lot 16D Mr. Eklund: On 4/22/2020, we performed a septic adequacy test on the 2003 bed drainfield at the subject prpperty. Prior to the adequacy test, a 2,003 gallon presoak was performed between 4/20/20-4/21/20. The MT's in the drainfield were dry prior to the test. On 4/22/2002, a total of 898 gallons were added to one of the cleanouts which caused a rise of 0.75" in one MT, a 0.5" rise in another MT, and the other MT's remained dry. After allowing the drainfield to recover for 156 minutes, the MT's were checked and all were dry. Based upon this data, the 2003 drainfield will absorb 600+ gpd and meets the absorption requirements for a COSA. As part of our evaluation of the system, we performed elevation shots of the entire septic system. The following are our findings in regard to the elevations: Elevations for the 2015 septic tank: Invert of FCO invert = 96.51 ST1 liquid level = 96.22 ST2 liquid level = 96.22 Invert of post tank DBL1 = 96.26 Elevations for 2003 bed: Average invert elevation of distribution lines are 96.40 (for CO1, CO2, CO4, COS, & CO6, did not include CO3 in this average since this CO has appeared to have settled) Average elevation of bottom of MT's = 95.90 (average of MT1, MT2, MT3, & MT4 — elevations ranged from 95.75-95.99 = 0.50 feet of effective (average) Elevations for 1985 bed: Average invert elevation of distribution line = 93.54 (CO7 = 93.55 & CO8 = 93.52) Elevation of bottom of MT5 = 93.07 = 0.47 feet of effective 3701 East Tudor Road, Suite 101 * Anchorage, Alaska 99507-1259 Phone: (907) 337-6179 * Fax: (907) 338-3246 * Website: www.garnessengineering.com Page 2 of 2 As can be seen from these elevations, there is gravity flow from the outlet invert of DBL1to the 1985 drainfield; but there is reverse grade to the 2003 bed. Basically there is a 0.14 feet (1.68" difference) reverse grade between the invert elevation of DBL1 (septic tank outlet) to invert elevation (average) of the distribution lines in the 2003 bed (96.26-96.40 = (-)0.14). In order to evaluate the functionality of the septic system, we added water to the foundation cleanout to see if the flow could reach the 2003 drainfield. The following is a description of this procedure: On 4/24/2020, we arrived on property and found the bull run diverter valve in the position that all flow was going to the 1985 drainfield. At 10:50 am, we started introducing water into the FCO and switched the flow on the Bull -Run (BR) diverter valve so that flow was directed to the 2003 bed. There is a CO directly after the BR and we could immediately see water flowing to the 2003 bed. Flow was introduced into the FCO at approximately 6.6 gpm. At 11:20 am, we checked the LL's in the FCO, ST1, ST2, DBL1, & the post BR CO. The FCO was still dry, the LL's in ST1 had risen by 2" in ST1 and 2.5" in ST2 from the level found on 4/21/2020. DBL1 had 2" of liquid in it and the post BR CO had 3" of liquid in it. Based upon a 6.6 gpm flow rate, approximately 200 gallons were added to the FCO and directed to the 2003 drainfield (no flow going to the 1985 drainfield). At 11:40 am, we checked the LL's again in the FCO, ST1, ST2, DBL1, & the post BR CO. The FCO was still dry and LL's in ST1, ST2, DBL1, & the post BR CO remained the same as the 11:20 reading. Based upon a 6.6 gpm flow rate, this equates to an additional 130 gallons (approximate) being introduced into the FCO and directed to the 2003 drainfield (no flow going to the 1985 drainfield). In short, approximately 330 gallons were added the FCO and directed to the 2003 bed in a 50 -minute period. Based upon this assessment, gravity flow can be achieved from the septic tank to the 2003 bed drainfield' however, the septic tank perate approximately 2 inches above the normal operation level. CW 1"64. At 12:20 pm, we checked the LL's in FCO, ST1, ST2, DBL1, & post BR CO. The FCO was still dry and the LL's in ST1 had dropped 1" in ST1 and 0.75" in ST2 from the level found on 4/21/2020. DBL1 had 1.5" of liquid in it and the post BR CO had 1.75" of liquid in it. At this time, we switched the Bull -Run valve so that the flow was directed back to the 1985 drainfield. Within 10 minutes of switching, the liquid levels in the tank and DBL1 dropped to within a 0.25" of where the levels were prior to this testing procedure. DBL1 had a small amount of flow going through it. We also performed an adequacy test on the 1985 drainfield. On 4/27/20, we performed a 1,974 gallon presoak on the 1985 drainfield by adding water to one of the CO's in the drainfield. On 4/28/20, we returned to the property and found the MT to have 0.5" of liquid in it (-5.5" below the invert of the distribution line). A total of 791 gallons of water were added to the northwest CO which caused the liquid level to rise to 5.5" (-0.5" below the invert of the distribution line). The introduction of water was stopped and 240 minutes later, the MT had 4" of standing liquid (1.5" drop) in it. Based upon this data, the 1985 drainfield will absorb 600+ gpd. CLOSING: Based upon our findings, either drainfield can absorb 600 gpd; however, utilization of the 2003 bed requires that the septic tank to operate in a slightly surcharged condition. Given the shallow burial depth, operating the system in a surcharged condition could be problematic during winter months; therefore, the 2003 drainfield should only be used during the summer months or a pump vault (to serve the 2003 drainfield) should be installed. , please contact me. 3701 East Tudor Road, Suite 101 * Anchorage, Alaska 99507-1259 Phone: (907) 337-6179 * Fax: (907) 338-3246 * Website: www.garnessengineering.com 4 ASBUILT 1 HEREBY CERTIFY THAT I HAVE SURVEYED THE FOLLOWING DESCRIBED PROPERTY: AND THAT NO E'' HMENTS EXIST 6CC PT AS INDICATED. IT IS THE 'RESPONSISI LL1 TY OF THE OWNER TO DETERMINE THE .EXISTENCE OF ANY EASEMENTS, COVENANTS, OR RESTRICTIONS WHICH DO NOT APPEAR ON THE RECORDED SUBDI- VISION PLAT. UNDER NO CIRCUMSTANCES SHOULD ANY DATA HEREON BE USED FOR CONs'rRUCTION OF FENCE LINES, OR FOR ESTABLISHING BOUND- ARY LINES. S&MRD & SCALE: DATE= GRID: FS DAWN (a) MUNICIPALITY OF ANCHORAGE DEPARTMENT OF HEALTH AND ENVIRONMENTAL PROTECTION DIVISION OF ENVIRONMENTAL HEALTH CERTIFICATE OF INSPECTION FOR HEALTH AUTHORITY APPROVAL OF ON-SITE SEWER AND WATER FACILITY 264-4720 Application Data ., GENERAL INFORMATION Legal Description (include lot, block, subdivision, section, township, range) Lot 16D Eagle River Valley Ranchet~es T14N RlW Sec.7 Location (address or directions) 70 Man Of War (b) Applicant Name Bill Mikawa Telephone: Home 6c)/4-c)661 Applicant Address 70 Man Of W~r Ea~le River 99577 (c) Applicant is (check one): Lending Institution I-I; Owner/builder 1~3; Buyer []; Other [] (explain); Business N/A (d) Lending lnstitution Alaska USA Credit Union Address "C" Street: Anchorage AK (e) Real Estate Company and Agent N/A Address Telephone 56~-~567 Telephone (f) MailtheHAAtothefollowingaddress: Pickup by En[ineer TYPE OF RESIDENCE Single-Family 19~ Multi-Family [] Number of'Bedrooms /4 Other WATER SUPPLY Individual Well~ Community I"1 Public [] Note: If community well system, must have written confirmation from the State Department of Environmental Conservation attesting to the legality and status. SEWAGE DISPOSAL Onsitel'~ Public1'1 Community[] Holding Tank [] Note: If community well system, must have written confirmation from the State Department of Environmental Conservation attesting to the legality and status. Page 1 of 2 72-025 (11,64! ENGINEERING FIRM PROVIDING INSPECTIONS, TESTS, FILE SEARCH, DATA AND INFORMATION As certified by my seal affixed hereto and as of the validation date shown below, I verify that my investigation of this Health Authority Approval shows that the on-site water supply and/or wastewater disposal system is safe, functional and adequate for the number of bedrooms and type of structure indicated herein. I further verify that based on the information obtained from the Municipality of Anchorage files and from my investigation and inspection, the on-site water supply and/or wastewater disposal system is in compliance with all Municipal and State codes, ordinances, and regulations in effect on the date of this inspection. F. AGLE RIVER ENGINEEI~ING $..~:~.- Name of Firm Telephone 1~.51.b HIVI;R, Al( ~Ub/I Address P.O. -n-riX 773:~9a Date ,/"~,/~/~ J'- 6§4-5195 DHEP APPROVAL Approved for ~;~ bedrooms by Date Approved ~'~ Disapprov~// '' Conditio~ Terms of Conditional Approval CAUTION The Muncipality of Anchorage Department of Health and Environmental Protection (DHEP) issues Health Authority Approval certificates based solely upon the representations given in paragraph 5 above by an independent professional engineer registered in the State of Alaska. The DHEP does this as a courtesy to purchasers of homes and their lending institutions in order to satisfy certain federal and state requirements. Employees of DHEP do not conduct inspections or analyze data before a certificate is issued. The Municipality of Anchorage is not responsible for errors or omissions in the professional engineer's work. Page 2 of 2 WELL DATA Well Classification /p~/'/' ~ Well Log Present (Y/N) Total Depth Cased to Static Water Level Casing Height Above Ground Electrical Wiring in Conduit (Y/N) Separation Distances from Well: To Septic/Holding Tank on Lot To Nearest Edge of Absorption Field on Lot To Nearest Public Sewer Line CleanouVManhole Water Sample Collected by Water Sample Test Results Comments MUNICIPALITY OF ANCHORAGE (MOA) HEALTH AUTHORITY APPROVAL (HAA) CHECKLIST - FEBRUARY 1984 264-4720 L,~q~al Description: ,,~,~-/~ ~ If A, B, C, D.E.C. A'l~proved (Y/N) , -; * Yield Date Completed · ' Depth of Grouting Pump Set At Sanitary Seal on Casing (Y/N) Depression Around Wellhead (Y/N) ; On Adjoining Lots ; On Adjoining Lots To Nearest Public Sewer To Nearest Sewer Service Line on Lot ; Date B. SEPTIC/HOLDING TANK DATA Date Installed /°,/V//'¢ ~ Standpipes (Y/N) ~ Air-tight Caps (Y/N) Depression over Tank {Y/N) Pumping/Maintenance Contract on File (Y/N) Holding Tank High*Water Alarm (Y/N) ,,,,~.'~//.,4 Separation Distances from Septic/Holding Tank: To Water-Supply Well .~o~'~' To Property Line /,p-t- v To Water Main/Service Line ,/c~ ~' Course Size /'"~'-¢' ~ No. of Compartments ,,/" Foundation Cleanout (Y/N) · Date Last Pumped ; for Temporary Holding Tank Permit (Y/N) To Building Foundation ~" ! To Disposal Field ,..Q ~1~/* "--' To Stream, Pond, Lake. or Major Drainage Comments page I of 2 72.026(11~84) ABSORPTION FIELD DATA Soils Rating in Absorption Strata Date Installed /~, Width of Field /,z/ · Square Feet of Absorption Area ~'~'~ '~ Depression over Field (Y/N) ~ Results of Last Adequacy Test ,,,~.x'~ 4~' Separation Distance from Absorption Field: To Water-Supply Well ....~_c,~, ~-' To Building Foundation /g · "- Lot ~ ~' / '"' Type of System Design Length of Field ~) / Depth of Field /"/ / Gravel Bed Thickness '~' Standpipes Present (Y/N) To Water Main/Service Line / ~ ~ '-'"- To Stream/Pond/Lake/or Major Drainage Course To Driveway, Parking Area, or Vehicle Storage Area Comments Date of Last Adequacy Test To Property Line .;~,E · To Existing or Abandoned System on ; On Adjoining Lots To Cutbank (it present) ~'~"'"'"~ "-' D. LIFT STATION Date Installed Size in Gallons "Pump On" Level at High Water Alarm Level at Tested for Electrical Codes (Y/N) Dimensions Manhole/Access (Y/N) "Pump Off" Level at · Vent (Y/N) Pumping Cycles during Adequacy Test. Meets MOA Comments S gned ** Check Permitted Bedroom Rating Against HAA Request ** I certify that I have checked, verified, or conformed to all MOA and HAA guidelines in effect on the date of this inspection. Date MOA No. ,.~7- ~'~ E 5" Company .~"~"~ Rece pt.o. Date of Payment Amount: $ ~ Page 2 of 2 72-026 (11,84) ........... MUN,C, PAL, TY OF ANC.ORAGE DEPAR~E~ OF H~LTH & EN~RONME~AL PROTEC~N ~ LS~-~A~I ENVIRONMENTAL ENGINEERING DIVISION Tde~e ~7~ REQUEST FOR APPROVAL OF INDIVIDUAL WATER AND SEWER FACILITIES DIRECTIONS: Co~ete all parts on page 1. IneomMeto mquesu ~ll not bo proceued, I~eam allow ten (I0) d~Vs for procesing. PHONE PHONE ' PHONE fi TYPEOF RESIDENCE ~ SINGLE FAMILY r-I MULTIPLE FAMILY 7, WATER EUPPLY [] INDIVIDUAL* [] PUBLIC UTILITY ' INDIVIDUAL/ON-SITE'" PUBLIC UTILITY - d NUMBER OF BEDROOMS  One [] Four [] Other Two r-I Five Three [] Six * ATTACH WELL LOG. A wail Io9 is required for all wells drill~ since June 1975. For wells drilled prior to that date, give well depth (attach log if available,) ? **If individual/on-site, gi~o imtallatlon date If system is over two (2) years old an adequacy test is required by this Department. NOTE: THE INSPECTION FEE MUST ACCOMPANY EACH REQUEST BEFORE PROCESSING CAN BE INITIATED, ' THIS SIDE FOR OFFICIAL USE ONLY ! DATE RECEIVE~ INSPECTION APPOINTMENTS ~ ' · TIME TIME TIME DATE DATE DATE INSPECTOR INSPECTOR INSPECTOR )IflECTIONS: 1. TYPE OF RESIDENCE NUMBER OF BEDROOM~ [] SINGLE FAMILY [] ONE I--I THREE [] FIVE [] OTHER [] MULTIPLE FAMILY [] TWO [] FOUR [] SIX PERMIT NUMBER 2. WATER SUPPLY [] INDIVIDUAL DEPTH OF WELL [] COMMUNITY DATE DRILLED [] PuBLIc UTI LITY Connection Verified LOG RECEIVED 3~ SEWAGE DISPOSAL SYSTEM PERMIT NUMBER [] INDIVIDUAL/ON -SITE DATE INSTALLED []PUBLIC UTILITY Connection Verified INSTALLER []SepticTank or I--IHolding Tank Size: If Tank is homemade SOILS RATING give dimensions: TYPE OF TANK MANUFACTURER TOTAL A~SORPTION AREA MATERIAL ~,"~PPROVED FOR --~ BEDROOMS [] CONDITIONAL APPROVAL (letter must accompany certificate) [~'~'DISAPPROVED~ ~' 72-010 (Rev. 3/78) October 1978 Sun,salty A~'C~: Hrs. ?enny~aChapelle P. O. Box 1201 Eagle R~ver, AE 99577 Melvin Stewart Property, I~t 16b, Eagle Ittver Eanchettes Dear Hrs. LaChapelle~ Per your reqUest, an upgrading of the sever system on the referenced property ~ms performed during the ~eek of 23 October 1978, A soi~ and percolation test was performed on 21 October 1978 as requested the H~icipalitY~s letter ~ted 28 Septe~er 1978, copy attached. ~ a reset of the soil test, an on-site s~er upyrade pe~t, ~8101~, vas issued by the Hmicip~ity. M i~pections, as required by pe~it con- ditions, were perfo~d by the ~dersi~ed and a copy of the o~-site sewage system i~pection report ia attached. ~e above ~=k to ~grade the system ~ong with the adeq~cy test sub- ~tted by ~H Cons~tants, Inc., shoed complete the ~equire~nts as specified by the Hu~cipality in their letter dated 28 September 1978." Ue appreciate the opport~ty to provide this se~ce to you and there are any questio~ zegardin~ the inclosed docents, please contact ~ ~pt of Health and En~ro~ntal Protection ~o~te~bar 29, 197~ Stuart Po=t Office Anchorage ~ SubJectl Lot 16D~agle P~vur Valley Ranchettes Subdivision The pa. rcolatAon te~t p~rfor~.ed on =h~ s~war system failed to pmus the a~e-~mcy test. ~erc~ore, before ~a ~my ~end an approval to th~ lenain9 ~l~ s~c~f~cation~ for tho u~gradu, A ~lt must ~ ~=sued after tho soils test ha~ been Xf ~ore ~u any further (~emt~on~ please contact this office at 264-4720. S~cer~ly, P~be=t Co Pratt~ cci E~ re~oral ~aving~ and Loan 535 D Street 99501 Judie ~land September 27, ]978 R&M No. 851589 Hel Stuart c/o Sun Realty P.O. Box 1201 Eagle River, Alaska 99577 Attention: Judy Rowland Re: Adequacy Test on Existing Sanitary, Sewer System; Ranchettes Subdivision, Eagle River, Alaska Dear Hr. Stuart: Lot 16D, Eagle River Per your request of September 8, ]978, we conducted a test of the sanitary sewer system on the above described property. Fifteen hundred gallons were pumped from the septic tanK. This.drew down the level in the seepage pit about one foot. During the test the liquid level in the seepage pit was monitored as 1000 gallons were removed and water was pumped back into the seepage pit to the inlet level. Ail liquid levels were measured below the top of the standpipe and are shown in the following table: Initial Liquid Second Water Third 24-flour Total Reading Removed Reading Added Reading Reading Drop (gallons) ~gallons) 5.20' 1000 8.70' 1000 6.00' 6.40' 0.40' The average specific capacity is 27.4 gallons per inch based on two sets of readings showing 23.8 and 30.9 gallons per inch. After twenty four hours the liquid level was measured again ~t 6.40 feet. It had dropped 0.40 feet or 4.8 inches. This indicates an average effluent acceptance rate of 132 gallons per day for the surrounding soils. If the 3 bedroom residence on the property is to house 6 people, the average load on the system can be expected to be 450 gallons per day. We can therefore conclude that the system is not disposing of effluent at an adequate rate for a 3 bedroom residence. September 2?, 1978 Hel Stuart Page -2- We appreciate this opportunity to be of service to you. Please contact us if you have any questions regarding this letter or if we can be of additional service to you. Very truly yours, R&~I Cg)NSULTANTS~ INC. . 6a ry/~A. Smith ~=ofect }lanager GREATER ANDHORAGE AREA BOROUGH Department of Environmental Quality 3500 Tudor Road, Anchorage, Alaska 99507 279-8686 Date Received Dec 15, 1973 ' Time of Inspection Date of Inspection REQUEST FOR APPROVAL OF INDIVIDUAL SENER & WATER FACILITIES FO2 1. Ao~roval Requested By: Selective Realty Address: 2. Prooertv Oaner: Dale Kachltne 3. Legal Description: Lot 16D, Eaqle Rtver Valley Rpnche~e$ a. Location: 5. Type of Facility to be Inspected: Stn~le Family OwelHn? Number of Bedrooms: T~IO (2) 6. Well Data: Con. unity A. Type C. Construction 7..Sewage Dlsoosa! System: Phone Phone Unknown A. Installed C. -Septic Tank: 1. Size D. Seepage Pit: 1. c~. Disposal Field: Distances: A. Well To: .Septic Tank · ~earest Lot Line B. C. B. Depth D~ 'Bacterial Analysis.' · 'g. ~nstaller '2. Manufacturer- Size 2. Material Total· Length of Lines , Absorption Area · Other Contamination Foundation to S.pttc Tank "~ 'Abso~tion Area Absorption Area to Nearest Lot Line Dec 28, 1973 · Sewer Lines ,~eqm.~t for Approval of 2no,'vtdual Sewer & Water Facilities Two 9. Comments~ Greater Anchorage Area Borough, Der~rtment of Environs. entel Quality DIAGRAM OF SYSTE~: ! certif), that the Information contained tn this request for approval to be a t~ue and accurate representation of the subject sewer and w~ter facilities located at~ Signed., Date tk. cerJor 28. 1973 V~terans Ad~lntstration 425 D. Street SUbOECTt Sewer and ~atcr system; Lot 16D £a~le River Yalley Ranchcttes. Cear Sir: l~e do z~ot have records o;) th~ s(~,c,r systc, nm for the subject lot, as instal- ]atim) w'es ~:ad~, prior to routine bisp(:ctions by ~he CA,'~ - Ilealth ~rtmer~t. The lo~ Is served by a;1 ', ,' ap,,rovej public J~ater surply, and the sc+tut syst~ ~oos ~Fparcn~ly consist of a septic - tan): - soil oL,sorF, tion syste~t. B~sed on t,,~ doc~entatton nlven to n,e by t~u Property owner, as to the sewer s~- tern installed, and alsn thu Inevitability oK public ~(~.~er ~tthb) the near future. (t seems reasonable tha: th~ s'~stem as tnstalle~ should fdnctton sattsf~ctori)y. If further clarification of this matter is n~eded please contact the £aqle Ktver office af tile ~epar:ment ef £nvlronnental Quality. ,',V~r~':tnceroiy yours, Lag/e ~,1~. rtis~' ~"~J~..~ict Sanitarian sr