HomeMy WebLinkAboutVALLI VUE ESTATES #2 BLK 1 LT 67Valli Vu Estates Block I Lot 67 #015-311-41  Municipality of Anchorage ."; ~,::, Development Services Department Building Safety Division On-Site Water end Wastewater Program. 4700 S. Bragaw SL P.O. Box 196650 Anchorage. AK 99519-6650 Page J of ~-. www.cLanchorage.ak.ue (907) 343-7904 ON-SITE WASTEWATER DISPOSAL SYSTEM AND/OR WELL INSPECTION REPORT PermitNumber: .~ l.4./d) l t::7_~ Oc~ PIONumber. &::) t~,t' ' 311 ' ~ / "" ~'o ~n ~'o.x~- Nastewater System: [] New [] Upgrade '~'"t~o~ I~oum~ '/'r,,'~_ b~';,,¢~ A,,d, ~D.¢'7 ABSORPTION FIELD P~' ~ ~ .9 - ,~ ~ -/6: 13 LEGAL DESCRIPTION O. ~*' 0!~/~{{ tO'*lf~ FIT I 6 '7 ., I/t, lll b",,,e ,~;t. ~ 2 "~. I F,. O.~ F,, '7 g ~,. Well: [] New [] Upgrade '~.5" ~. ~"1 ~ TANK SEPARATION DISTANCES ~ septic I-] Holding 1"1 s.'r.£.P. [] Othe~  Septic Absorption Lift Holding PublicG'fivate Tank Field Station Tank Sever Line ~n C~or~e -['~4 - 5'h~¢ I w,,, ~T. OO' 9' ZOO' -- " . \¥/ L, FT STAT,ON s,~cew,m ~,lO0° · tOO' -- s,z. ~'~..-~, ..~.~, BENCH MARK Engineer's Stamp ., . OFA Inspections performed by: ~"/cr,Z/~'/' '~'~g "~'*'¢' Dates: 1~ ~/2.1/Ol 2~ ~/~/~1. e.,,,,,,,,,.,,,,,,,,o,,..,.~ Development Services Departmen~.~t Ap, proval ~. .... Reviewed and approved by' //~/,~-'"'~/ $'U. ~--"~ate:-.~' ~," O,,~,. ¥,~".. CE.3587 ;'At'' ,,~.. ,:~, ~/7~ ~ ,~.. ~-~ · ........ PERMIT NO: SW010309 PID NO: 015-311-41 SWING TIES: FROM: COR. "A" TO: S.T.C.O. "E" 6.5' S.T.C.O. "F" 12' DBL. C.O. "G" t3' TR. C.OJM.T. "H" 20' TR. C.O.IM.T. '1" 71' TR. C.OJM.T. "J" 46' COR.'B" COR."C" 32.5' 33.5' 33' 22' 46.5' 18.5' 64' 35' PAVED DRIVE ! DECK PLAN VIEW SCALE: 1"= 30' PAGE 2 OF 2 NEW 76' LONG · SOILABS. TR. W. 8.7' GRAVEL NEW 1000 GAL 2' SOIL COVER SEPTIC TANK I 95.6' PROFILE VIEW NOT TO SCALE ...-.....~..'~ ~.' /[ ~eleeeleleeeeeeeeeeeeeee eee~ '~, ~,~TH~ODO~ ~. ~ ~ 2' SOIL COVER -- 2" RIGID INSULATION MOUNDED TO 3'+ SOIL COVER -- ;~IBUTION PIPE INV; ELEv: 08.2' (I iC ,'', 76' LONG SOIL ABS. TRENCH , , WITH 8.7' GRAVEL BELOW PIPE -- Bo3-rOM TRENCH BOTTOM T.H.#1M.T ELEV. 78.9'. DRY8DI~I LOT 67, BLOCK 1, VALM VUE EST., UNIT #2 SEPTIC SYSTEM UPGRADE AS-BUILT INSPECTION REPORT FI..ATrOP TECtINICAL SERVICES 14~;30 ECIIO STREET ANCllOP, AGE. ALASKA 9<)516 SCALE: AS NOTED DRAWN BY TFM AUGUST, 2001 MUNICIPALITY OF ANCHORAGE Development Services Department On-Site Water & Wastewater Program 4700 South Bragaw Street P.O. Box 196650, Anchorage, AK 99519-6650 (907) 343-7904 ON-SITE WASTBNATER DISPOSAL SYSTEM PERMIT Upgrade Date Issued: Aug 10, 2001 Expiration Date: Aug 10, 2002 Permtt Number: SW010309 Legal Description: VALLI VUE ESTATES #2 BLK I LT 67 Design Engineer: 0019 Flattop Technical Services Owner Name: John Bost Owner Address: 6800 ROUND TREE DR ANCHORAGE, AK 99516-6819 Parcel ID: 015-311-41 Site Address: 006800 ROUND TREE DR Lot Size: 20379 SQ. FT. Total Bedrooms: 3 Permit Bedrooms: 3 This permit is for the construction of: [] Disposal Field [] SepticTank [] Holding Tank [] Privy [] Private Well [] Water Storage All construction must be in accordance with: 1. The attached approved design. 2. Ail requirements specified in Anchorage Municipal Code Chapters 15.55 and 15.65 and the State of Alaska Wastewater Disposal Regulations ( 18AAC72 ) and Drinking Water Regulations ( 18AAC80 ). 3. The engineer must notify DSD at least 2 hours prior to each inspection. Provide notification by calling (907) 343-7904 ( 24 hours ). ( Not required for a Water Supply Permit only ). 4. From October 15 to April 15, a subsurface soil absorption system under construction during freezing weather must be either: A. Open and closed on the same day. B. Covered, sealed, and heated to prevent freezing, Received By: Issued By: Date: Date: Municipality of Anchorage Development Services Department Building Safety Division On-Site Water and Wastewater Program o 4700 South Bragaw St. P.O. Box 196650 Anchorage, AK 99519-6650 www.ci.anchorage.ak.us (907) 343-7904 ON-SITE SEWEPJVVELL PERMIT APPLICATION FOR A SINGLE FAMILY DWELLING Parcel I.D. O t.5-- - ,~1!" ¥ I Permit Number . Day phone_ Property owner(s) Mailing address (1) Mailing address (2) Legal description (Lot, Block & Sub'd.) L, ./- ,6'?: Legal description (Section, Township & Range) Lot Size c,~ '7 c~ .Acr~ Zip Code q~,.~o 7' Number of Bedrooms THIS APPLICATION IS FOR: Sewer Only Sewer and Well Sewer Upgrade THIS PROPERTY CONTAINS: Hot Tub Swimming Pool Therapy Pool Well Only Water Storage Jacuzzi Water Softening Unit I certify that the above information is correct. I further certify that this application is being made for a Single Family Dwelling and is in accordance with applicable Municipal Codes. (Signature of property owner or authorized agent) Permit Fees: Date of Payment: Receipt Number: (Rev. 12/00) Waiver Fees: Date of Payment: ~' Receipt Number: CIVIL & ENV~ONMENTAL ENGINEERLNG" ENERGY CONSERVATION & ANALYSB THEODORE F. MOORE, P.E. 14530 ECHO ST. PH: (907) ~45-1355 August 3, 2001 ANCHORAGE, ALASKA 99516 M.O.A. DSD P.O. Box 19-6650 Anchorage, AK 99519 Dear Sirs: The purpose of this letter is to provide the required design narrative in support of our application for a permit to upgrade the wastewater disposal facilities on Lot 67, Block I, Valli Vue Estates, Unit//2, located at 6800 Round Tree Drive. The original system is no longer able to accept the wastewater flow generated in the residence. A soils log, pete test results, a site plan, design drawings and specifications are enclosed for your review. The proposed system will be constructed in the vicinity oftest hole # 1. As carl be seen from the soil log, the native material between 1.5 feet and 13 feet is a variable silty sandy gravel. A couple of small seeps were noted in the test hole, emanating from just above a silt stratum, but no groundwater built up in the monitor tube so I concluded that these seeps were only trapped water. Although the measured absorption rate at the pete test location turned out to be slightly less than I minute per inch, I recommend that for design purposes a soil application rate of 0.6 gpd/square foot would be more representative. Thus, this 3- bedroom residence requires a total absorption area of(3 x 150)/0.6 = 750 square feet. The proposed 75-foot long trench design with an effective gravel depth of 9.5 feet has a total absorption area of 1425 square feet. The topography of the lot in the area of proposed construction slopes generally gently towards the north and east. Fill has been placed north ofthe test hole to create a pad for the paved drive, and the northernmost portion of the trench will pass beneath the toe of that filled area. A S-foot long plug of undisturbed soil will be left at the east end of the short leg ofthe trench to provide separation. The proposed project will have no significant impact on present or future water supply and wastewater disposal systems serving adjacent properties, nor will it have any significant impact on reserved space-surface and subsurface, or on drainage. Please give me a call at 345-1355 ifyou have any questions on this submittal. Sincerely, Ted Moore, P.E. LOT 1 ~'6~'~' BLOCK 6 \ \ LOT 15 BLOCK LOT 68 O SEPTIC PAVED; WATER SERVICE ABANDON EXISTING __ SEPTIC TANK SoEPTIC LOT 65 ' NOTE: ALL RESIDENCES IN THIS SUBDIVISION ARE SERVED BY A CLASS "A" COMM. WATER SYSTEM POWER PEDESTAL (APPROX. LOCATION) ,, ,, -- CONSTRUCT NEW 75' LONG SOIL ABS. TRENCH W, 9.5' GVL. INSTALL NEW 1000 GALLON SEPTIC TANK TRACT F-1 HILLSIDE PARK P.U,D. :49 CE - 3589 LOT 67, BLOCK 2, SEPTIC SYSTEM U~GRADE SITE PLAN , SERVICES 14530 ECllO STI~ET A~CtlORAGE, ALASKA 99516 NOTE: THIS IS NOT A SURVEYED PLAT. ALL LOCATIONS SHOWN ARE APPROXIMATE. ~IT #2 I1 INCH = 50 FEET DRAWN BY TFM JULY, 2001 "A" 4" DI~ 1:)-3034 NON-PERF. 4" DI~ F-810 PERF. DIST PIPE 55 /--- M.T. / -~ CONSTRUCT 75' SOIL ABSORPTION TRENCH __ W. 9.5' EFF. GRAVEL BETVV. 2.5' & 12' B.G.L DBL. C.O, INSTALL NEW ~ 1000-GALLON ~ SEPTIC TANK M.T. NEW WASTE C.O. LINE FROM ---~' HOUSE PLAN VIEW SCALE: 1" = 10' 3 MONITOR TUBE IACKFILL / - ORIGINALGROUND -- .'ILTER FABRIC -- 4" DI~ F-810 PERF PIPE -- I/2" - 2 1/Z' SEWER GRAVEL SECTION "A - A" SCALE: 1" = 5' IOTTOM OF EXCAVATION LOT 67, BLOCK 1, VALLI VUE ESTATES #2 SEPTIC SYSTEM UPGRADE PLAN AND CROSS-SECTION FLATTOP TECIINICAL SERVICES 14530 ECtlO STREET ANCI IORAGE, AK, 99516 SCALE: AS SHOWN DRAWN BY: TFM AUGUST, 2001 TEST HOLE FLATTOP TECHNICAL SERVICES 14530 ECHO ST. ANCHORAGE, ALASKA 99516 SOILS LOG -- PERCOLATION TEST LEGAL DESCRIPTION:._L0t.~10¢k 1. Vatli Vue,.Estates, Unit DATE PERFORMED: JU~,~01 PERFORMED FOR: John Bost GM Silty gravel fill DEPTH -- (feet) __ Pt. Topsoil SM Reddish sandy loam 9- GM Sitty sandy gravel Gray, dP/, highly variable Many cobbles and boulders Lenses of ML and of SP/SM Hard digging ML Gray sandy silt lens Small seep of trapped water SLOPE Depth to Groundwater Date Srnall eeep_~ 13' 7/23/01 '-~onitor tube dp/ 7/30/01 SITE PLAN .10% Itl 19 20- ML Gray sift SP/SM Silty sand B.H. Clock Net Time Percometer Net Drop Date Reading Time (minutes) Reading (inches) 7/23 1ZLLP_r_~ ~]] k 27 1/2 12" ResQQk 27-T/2__ Add__water & start 5:44:15 23~3/4 #1 5:49;15 5 16..3/4 7 Add water 5:_50 23_118 ~ 5:_55 5 16_3/4 (dry) 6 3/8 Add water 5:55:30 23_3/8 #3 6~'00~30 5 16 3/4 6 5~ PERCOLATION RATE <1 (minutes/inch) PERC HOLE DIAMETER TESTRUN BETWEEN 5.5 FTAND 6.0 FT COMMENTS: GM_stmtum. bJ3jghly variable In consiste~;Y-~th manY-smalUe~es-of-ML-az~L~ P/SM--Eyel3~ e m atedaLel3~ ulltemd in the perc test was variable. Despite hi(3hmeasured perc rate, recommend basin{3 desil3n on 0.6 gpd/sq, ff. PERFORMED BY FLATTOP TECHNICAL SERVICES. I.~'_-~,~ ~ CERTIFY THAT THIS TEST WAS PERFORMED IN ACCORDANCE WITH ALL STATE AND MUNICIPAL GUIDELINES IN EFFECT ON THIS DATE· DATE: ,,~ ~'-~ J~3, I q:fattop q'ecilnica£ Sendces 14530 ~oc[io Street, .flnc~orage,.flR 99516 ~Pf~one (907) 345-1355 Lot 67, Block 1, Vaili Vue Estates, Unit #2 6800 Round Tree Drive Wastewater disposal system installation Specifications 1.0 General: 1.1 The scope ofthe project consists ofabandonment oran existing septic tank and seepage pit and installation ora new 1000-gallon septic tank that discharges effluent into a 75-foot long soil absorption trench containing a total of 10 feet of sewer gravel. 1.2 Construction shall be as depicted on the approved site plan and design drawings. Minor deviations from these drawings may be allowed or required by the engineer conducting the inspections. All construction procedures and material specifications shall conform to Municipal and State requirements. All separation distances shall be in conformance with Municipal requirements, unless specifically waived. 1.3 The contractor shall be responsible to obtain any necessary utility locates, and to work around any buried utilities. Prior to the start of construction, the homeowner or contractor shall arrange for a survcs'or to locate the northec~st pro£erty corner and to set lath on the pro£ert~ lines at 2$foot inters,als for l OOfeet south of the northeast corner and 2Sleet west of the northeast pro£erty corner. 1.4 The contractor shall provide adequate cover material and rough grading over all system components to ensure that proper drainage is achieved after settlement and that there are no residual depressions. Insofar as possible the contractor shall minimize damage to trees and existing lawn areas. Particular care shall be taken in excavating the discharge line between the septic tank and the new trench to minimize disturbance to tree roots, portions of this line may have to be dug by hand. 1.5 Unless specifically agreed otherwise, the homeowner shall be responsible for finish grading after the soil is compacted, as well as placement oftopsoil and reseeding all areas disturbed by the construction. 2.0 Septic Tank: 2.1 The existing single-compartment 1000-gallon septic tank and 6-foot deep by 3-fuot diameter steel ring seepage pit must be properly abandoned by thoroughly pumping to remove all wastewater effluent, followed by pumping them both full with a weak concrete slurry. 2.2 The new 1000-gallon, 2-compartment septic tank shall be Municipally approved and shall be set level on undisturbed soil at a 2-foot burial depth. Each compartment shall be equipped with a watertight manhole cover and a 4" cleanout. The tank shall be insulated with 2 inches ofapproved burial type, rigid insulation. 2.3 All pipe connections to the tank shall be equipped with waterproof'mechanical couplings. A new waste line shall be installed exiting from the crawl space in the southeast comer of the residence to the new septic tank with a minimum slope of 1/4'" per foot. The waste line between the tank and the ' soil absorption system shall have a minimum slope of 1/8" per foot. A cleanout shall be installed within 5 feet of the building foundation, and a double cleanout shall be installed within 5 feet downstream of the septic tank. 3.0 Soil absorption system: 3.1 The soil absorption system shall be constructed by excavating a 55-foot long trench and a 20- foot long trench to a depth of 12 feet below ground level in the vicinity of the test hole. 3.2 The bottom ofthe excavation shall be level. Any compacted or smeared surfaces shall be raked to allow proper infiltration. Sand for leveling or serving as filter material shall comply with Municipal specifications. 3.3 A total of 10.0 feet of approved sewer gravel shall be placed in the bottom ofthe excavation with the perforated distribution pipes laid level such that the pipe inverts are no less than 9.5 feet above the bottom ofthe sewer gravel. The discharge line from the septic tank shall be connected into the F- 810 perforated distribution pipe at a point no further than 50 feet from the far end ofthe system-Sewer gravel shall be 0.5" - 2.5" screened gravel, with less than 3% passing the #200 sieve. 3.4 Monitor tubes and cleanout pipes shall be of 4" diameter and installed in the locations shown on the design drawings. The portion of the monitor tube extending through the sewer gravel shall be perforated. 3.5 Approved filter fabric shall be placed over the entire top surface of the sewer gravel. A minimum of 2 feet of soil cover is to be placed over the filter fabric. Ifthe soil cover thickness is less than 3 feet, two inches of rigid, burial type insulation is to be placed over the entire top surface of the gravel, in addition to the filter fabric. 3.6 The top surface of the cover material shall be raised a minimum of 6 inches higher than the surrounding terrain to allow for subsequent settlement, and shall be graded to smooth contours. Fill slopes shall be no steeper than 3:1. 3'.7 Unless specifically agreed otherwise the homeowner shall be responsible for arranging to have the site finish graded after the backfill material has stabilized, and for placement of adequate topsoil and seed to promote rapid revegetation of all areas disturbed by the construction. 4.0 Inspections: 4.1 A minimum of 4 engineering inspections will be required during the course ofthe project: (1) initial stakeout with the contractor to establish the location of the system and to discuss the plans, specifications and construction procedures, (2) after the native material has been excavated to expose the infiltrative surface to ensure that it is level and at the right elevation, and conforms with the soil test information, (3) after the sewer gravel is in place and the distribution pipes have been laid and connected up to the septic tank, but prior to placement of insulation or filter fabric, and (4) after rough backfill and grading is complete. The septic tank requires one inspection after it is set level and the piping connected, but prior to backfill. This inspection may be incorporated with any of the above inspections. 4.2 The installer shall coordinate the timing of the inspections with the engineer sufficiently far in advance to ensure the availability of the engineer. ~GREA, ER ANCHORAGE AREA BOR~dGH Department of Environmental Quality 3330 C Street Anchorage, Alaska 99503 INSPECTION REPORT ON-SITE SEWAGE DISPOSAL SYSTEM P~ONE SEPTIC TANK: DISTANCE ~ ' FROM WELL MANUFACTURER INSIDE LENGTH ~ INSIDE WIDTH SEEPAGE PIT: BUILDING FOUNDATION ~ MATERIAL LIQUID DEPTH  NUMBER OF COMPARTMENTS LIQUID CAPACITY /~-) GALLONS. ? / DIAMETER O~ DEPTH g / _ DISTANCE FROM: WE . . ' c;,~/ . TOTAL EFFECTIVE / NEAREST LOT LINE ABSORPTION AREA (WALL AREA) 3~O SQ. FT. ADDITIONAL ABSORPTION WELL: TYPE ~' /)/t~,~ CONSTRUCTION BUILDING NEAREST FOUNDATION LOT LINE DEPTH DISTANCE FROM: NEAREST SEPTIC SEEPAGE SEWER LINE TANK SYSTEM CESSPOOL , OTHER SOURCES APPROVED DISAPPROVED DISTANCES: INSTALLEDBY: ~/~,. / PIPE MATERIAL: LOT SLOPE: REMARKS: REMARKS /~-5~-/<~ 'TD~A~GRAM OF SYSTEM :R ANCHORAGE AREA BOF '\JGH DEPARTMENT OF ENVIRONMENTAL QUALITY 3330 "C" STREET ANCHORAGE, ALASKA 99503 TELEPHONE 274-4561 LEGAL DESCRIPTION SEWAGE DISPOSAL SYSTEM -- APPLICATION AND PERMIT OTHER INSTALLATION OF: SEPTIC TANK SEEPAGE PIT DRA~N FIELD SOIL TEST RESULTS COMPLETION DATE ANTICIPATED FINAL INSPECTION: 24 HOUR NOTICE REQUIRED. BACKFILLING OF ANY SYSTEM WITHOUT FINAL INSPECTION BY THE DEPARTMENT OF ENVIRONMENTAL QUALITY AUTHORITY WILL BE SUBJECT TO PROSECUTION. MINIMUM DISTANCEB, REQUIREMENTS FOUNDATION TO SEPTIC TANK SEPTIC TANK TO SEEPAGE PIT WALL SEPTIC TANK , SEEPAGE PIT TO NEAREST LOT LINE. WELL TO SEPTIC TANK DRAIN FIELD ~ · SEEPAGE PIT ALSO CONS[DER AREA WELLS. WATER MAIN TO SEPTIC TANK . SEEPAGE PIT DRAIN FIELD / SE,'T,O TAN'<, /¢'4¢ SEEP AGEP'T ':'"A'" toLD TO RIVER· LAKE, STREAM. CAST IRON INTO AND OUT OF SEPTIC TANK AND INTO CRIB CROSSING GAP OF EXCAVATION 5 FEET INTO UNDISTURBED SOIL. 4 INCH DIAMETER CAST {RON SIPHON PIPES ON SEPTIC TANK AND SEEPAGE PIT FITTED WITH AIRTight REMOVABLE CAPS. GRA~/EL BACKFILL CONFORM TO BOROUGH REGULATIONS REGARDING INSTALLATION' ~.~.2.~. DIAGRAM OF SYSTEM I CERTIFY THAT I AM FAMILIAR WITH THE REQUIREMENTS OF GREATER ANCHORAGE AREA BOROUGH ORDINANCE NO. 28-68 AND THAT THE ABOVE DESCRIBED SYSTEM iS IN ACCO ANC£ WITH SAID CODE.(9- ~'' ~' j~,,~.~D ~~~~ ~- ' DATE . APPLICANTS SIGNATURE ¢ GREATER ANCIIOkAGE AREA BOROUGh Department of Environmental Quality 3330 "C" Street Anchorage, Alaska 99503 SOILS I,OG PEROI,ATION TI£ST Performed for ~:_N~S~t~ ~ ~ ~ Legal Descrip~i-o]l: ]jj-J~._:-~-~j~ ~' This form reports:, Soils log / Date Pe rfo n;ied_.~:.-_~_F? ,S:L Percolation test Depth Feet 2- 3- 4- 5- 7- 8- 9- 1e- l1 - 12- 13- Was ground water encountered? If yes, at what depth? Reading Date Gross Time Net Time Depth to Water Net Drop Pe rcol all o~ 'r-a-~- .......... }lFi~n u t e-: -Proposed 'Installation Seepage Pit Drain Field Dept~F-t-O'-b-o-~l:~-6-f--pit or trenci~ Depth of Inlet .............. · ...................... COMMENTS: .................................................... -- ...................... [)ate (6174) /77 ~ ~ MUNICIPALITY OF ANCHORAGE MUNICIPALITY OF ANCHORAGE DEPARTMENT OF HEALTH & ENVIRONMENTAL PROTECTIO~I~pT. C,i' J;f/',LT;~ & 825 L Street- Anchorage, Alaska 99501 ENVIRONtV.~NI,:,L ~'k, :!CTION ENVIRONMENTAL ENGINEERING DIVISION Telephone 264-4720 DEC 1 I978 REQUEST FOR APPROVAL OF INDIVIDUAL WATER AND SF_~I~J~(JlVI~I J~ DIRECTIONS: Complete all parts on page 1. Incomplete requests will not be processed. Please allow ten (10) days for processing. 1. PROPERTY OWNER John E;/Eleano~ E. "Ni'S~ ' .... ' MAILING ADDRESS 6800 Round Tree Drive 99502] PROPERTY RESIDENT (If different from above) PHONE 349-3910 r PHONE 2. BUYER PHONE Joh~ M./Pat-ridia C~ Bost ' 333-7493 MAILING ADDRESS 3147 Donnington Drive 3. LENDING INSTITUTION PHONE Alaska Pacific Bank 274-9661 MAILING ADDRESS 101 Benson -Boulevard 99503 4. REALTOR/AGENT Clair Ramsey--%'Jack'Wh'ite' Company MAILING ADDRESS 32'01 C Street 99501 5. LEGAL DESCRI~ION Lot 67 Block-lfVal'li ~u~ Estat~s~'Subdi~zs~on ~1 JPHONE 277-1553 STREET LOCATION 6800 Roufld T~ee 'D~'i~e 6. TYPE OF RESIDENCE NUMBER OF BEDROOMS [] One [] Four I'-i Other__ r~X SINGLE FAMILY [] Two [] Five [] ' MULTIPLE FAMILY ' ' r"~× Three [] Six 7. WATER SUPPLY [] INDIVIDUAL* c[~× COMMUNITY [] PUBLIC UTILITY ATTACH WELL LOG. A well log is required for all wells drilled since June 1975. For wells drilled prior to that date, give well depth (attach I~g if available.) S. SEWAGE DISPOSAL SYSTEM ~X INDIVIDUAL/ON;sITE""' If system is over two (2) ,/ears old an adequacy test is required [] PUBLIC UTI LITY ' by this Department. NOTE: THE INSPECTION FEE MUST ACCOMPANY EACH REQUEST BEFORE PROCESSING CAN BE INITIATED. 72-010(3/78) Note: pumping receipt attached. THIS SIDE FOR OFFICIAL USE ONLY DATE RECEIVED INSPECTION APPOI NTM ENTS T~ME TIME TIME DATE DATE DATE INSPECTOR INSPECTOR I NSPECTO R DIRECTIONS: I. TYPE OF RESIDENCE NUMBER OF BEDROOMS [] SINGLE FAMILY [] ONE [] THREE [] FIVE [] OTHER [] MULTIPLE FAMILY [] TWO [] FOUR [] SIX PERMIT NUMBER 2, WATER SUPPLY [] INDIVIDUAL DEPTH OF WELL' [] COMMUNITY DATE DRILLED [] PUBLIC UTILITY . Connection Verified LOG RECEIVED 3. SEWAGE DISPOSAL SYSTEM PERMIT N~U~UMBER~'~ []INDIVIDUAL/ON -SITE i--IPUBLIC UTI LiTY ...... : D~'~.IN TALL½s ED . Connection Verified INSTALLER []Septic~T.~n~.or []Holding Tank ::, ~: ........ : ...... Size:_~/_.~;J/.t~7.~(.J IfTank is homemade I SOILS RATING give dimensions= t' ~,~' .~ MANUFACTURER ~...: , : ......... TOTAL ABSORPTION AREA MATERIAL 4, DISTANCES WELL TO: Septic/Holding Tine Absorption Area, Sewer Line Nearest Lot Line Absorption Area to nearest Lot Line , . 5. COMMENTS ...... , ,: · ....... ~...::.,: ';::'1::.- :;'- ; ....... APPROVED FO" 7 : BEDRooMs [] CONDITIONALAPPROVAL.(letter must accompany certificate) [] DISAPPROVED . LEGAL DESCRIPTION 72-010 (Rev. 3/78) GREATER ANCHORAGE.AREA BOROUGH Department of Environmental Quality 3330 "C" St., Anchorage, Alaska 99503 - 274-4561 REQUEST FOR APPROVAL OF INDIVIDUAL SEWER & WATER FACILITIES Type of Inspection: CMRO Property Owner: Co5n E. Mailing Address: 68'00 Round Tree D~. Name of Buyer: John M. and Patricia C. Bost Mailing Address: 3147 Donnington, Drive Day Name of'Lending Institution: ~ Alaska Pacific Mailing Address: .101 Benson Name of Realtor or Agent: Clair Ramse¥ Mailing Address: 3201 C St. ~ VA FHA CONV xxx And Eleanor E. Nist D~y Phone 349-3~10 Phone 333-7493 Phone 274-9661 Jack White Co. Phone 277-1553 o Lot 67, Blk 1, Val~i rue Estates Uhit ~2 Legal Description: Location: 6800' Round Tree Dr. --,~ If Individual, If Individual, Sewage Disposal Type of Facility to' be inspected: WaterlSupply.~ommu~i~.xi~xell Type of Supply: Public Utility numbed of dwellings depth of well System Type of System: Public Utility __ If Individual, date of installation home No. Bdrms. 3 Individual presently served Indigidual (on-site) xx EQ-037 (1/7q) GREATER ANCHORAGE AREA BOROUGH Department of Environmental Quality Street, Anchorage, Alaska 99503 274-4561 Date Received February 8, 1977 Time of Inspection 10:00 a.m. Date of Inspection 2-9-77 Wednesday REQUEST FOR APPROVAL OF INDIVIDUAL SEWER & WATER FACILITIES FOR JKennedy 1. Approval requested by: Mailing Address: 535 2. Property Owner: Cony. Home Federal Savinqs and Loan D Street Phone: Robert J. Lutje Phone: 272-1451 344-4602 272-1. Mailing Address: Star Route A Box 31-L 3. Legal Description: Lot 67 Block 1 Valli Vue Estates 4. Location: ~5. Type of facility to be inspected Single Fa_mily 6. Well Data: No, of bedrooms 3 A. Type Community C. Construction Sewage Disposal System: A. Installed C. Septic Tank: D. Seepage Pit: 1. B. Depth D. Bacterial Analysis On-site system ~ot~ B. Installer 1. Size I~])~O~. 2. Manufacturer Absorption Area ~Zo~ .~3 ' 2. Material E. Disposal Field: Total length of lines 8. Distances: A. Well to: Septic tank , Absorption area , Sewer Lines , Nearest lot line , Other contamination B. Foundation to septic tank , Absorption area C. Absorption area to nearest lot line EQ-034 (1/74) Page~l of two pages ?age~2 of. two pag~es - Re~st for Approval of Individual . er & Water Facilities Legal Description Lot 67 Block 1 Valli Vue Estates Comments Approved//.~~O_~4/t/I/t_.~isapproved Approval Valid for one year from date signed Greater Anchorage Area Borough, Department of Environmental Quality DIAGRAM OF SYSTEM certify that the information contained in this request for approval to be a true and accurate representation of the subject sewer and water facilities and these facilities are operating satisfactorily. SIGNED Date EQ-034 (1/74) DEPT. Ol: H~AL~H & MUNICIPALITY OF ANCHORAGE ENVIRONMENTAL PROTECTION DEPARTMENT OF HEALTH AND ENVIRONMENTAL PROTECTION 2510, East Tudqr, Road, Anchorage, Alaska99504 ~ FEB 8 1977 REQUEST FOR APPROVAL OF RECEI INDIVIDUAL SEWER and WATER FACILITIES I. Type of Inspection: CMRO. VA FHA. .CONV 2. Property Owner: Robert J. Lutje Mailing Address: SRA Box 31-L Day Phone: 344-4602 Anchorage, A]aska 99507 3. Name of Buyer: ._T_A_h~ Mailing Address:. Day Phone: 4. Name of Lending Institution: Mailing Address: 535 D. Street 99501 Phone: 272-1451 5. Nameof Realtor or Agent: Bonnie L. Hehner Mailing Address: SRA Box 35H 6. Letjal Description: Phone: 349-1383 Lot 67, Block 1 - Valli Vue Estates Subdivision X Location: O~Malley between Birch & Hillside, north site 7. Type of Facility to be Inspected: 8. Water Supply Type of Supply: Single Family Residence No. Bdrms. 3 Public Utility. If Individual, number of dwellings presently served If Individual, depth of well Sewage Disposal System Type of System: Public Utility If Individual, date of installation ,Individual. Commun i ty Individual (on-site) X 72-003(3/76)