ON-SITE WASTEWATER DISPOSAL SYSTEM AND/OR WELL INSPECTION REPORT
permit Number: SW010093 PID Number; 020-172-49
"~°: Wastewater System: New
Spinell Homes
9210 Vanguard Drive Anc.T AK 99507 ABSORPTION FIELD
:344-5678 Four (4) Bottomless Sand Filter
LEGAL DESCRIPTION 2 c~o~ 5.5
4 8 Mountainside Village #1 :3 n. .5
3 ~,. 30
Well: New 12 .. 4 2
207 n. 77 n. 360 Fe ASTM D3034 PVC
Alpine Drilling 7/26/01 63.. Spinell Homes 8/15-18/01
'""'": 8 ona In''"'s~':,~, ic~,~, .,~.~,~,,~ c,,~:2 ~, TANK
SEPARATION DISTANCES S.T.E.P.
~ Sep~c AbsorpUor Uft Holding ~ublictPrlvate
Tank Field Stalion Tank S~,,U~ Anchorage Tank 1,500
w. >100' >100' >100' N/A >25' Steel Three(3)
v..w,,,~>100' >100' >100' N/A '~ / LIFT STATION
~ >5' >10' >5' N/A 250 c~ Anchorage Tank/Orenco
F,~ >S' >10' >5' N/A 43 'e. 43
c,,~o,~ qone doted Orenco Municipality of Anchora~:e
~ BENCH MARK
Garage Floor Slab
100.0
EngineeCs Stamp
pedorr~ed by: MEA Dates: 1" 8/15/01
Inspections
'~ 2'~ 8/18/01
Department of Health and Human Services approval
No.
Municipality of Anchorage
DEVELOPMENT SERVICES DEPARTMENT
4700 South Bragaw Street Anchorage, AK 99519-6650 - 343-7904
On-Site Wastewater Disposal System or Well Inspection Report
Page 2 of 3
Permit Number SW010093
PID No. 020-172-49
Alterna
Site
PLAN AS-BUILT
SCALE 1" = 40'
%
[ir Compre.ssqr. a~_
uauge Lbca~eo ~n ~mrage.
49th
Municipality of Anchorage
DEVELOPMENT SERVICES DEPARTMENT
4700 South Bragaw Street Anchorage, AK 99519-6650 - 343-7904
On-Site Wastewater Disposal System or Well Inspection Report
Page 3 of 3
Pe~nit Number SW010093
PID No. 020-742-49
/~ 1,500 C~L.
92.8 ' STEP Tank
93.0
99.0
Fl'6shi.n?. /
Valve
. Ge6texgile Fabric-*
2' Filter Sand -\
82.0
PROFILE AS-BUILT
1' = 10'
6'! of 3/8" Pea
Gravel
95.0
--Airline
~Permit Number:. #SW 010093 Date of Issue: .4/30/01 Parcel Identification Number: 020-172-4g
Date Started: 7-25-0f Date Complected: 7-26-01 Is wcH located at approved i~mit location? [] Yes [] No
:Legal D~scripiton: Mountainside Villeqe #1 81k4, Lot 8
Property Owner Name & Address: Spinell Homes
I
§210 Vanguard Drive
,4nchorage. AK 99507
]J~'pth (ft) Method of Drilling [] air rotary [] c~le tool
From To
Casing type: steer
Borehole Data: ....
SoX Type, Thickness & Water S~za~a
stick-up 0 2
organic & silt -!2 7'
gravel¥ silt 7 4 f
silt 41 48
gravelly silt 45 61
bedrock 01 207
Atteatiom The w~ll &ille~ sluJl provide
Wall Thickness: .025 inches
Diameter: 6 inch~s Deptk ZZ fee~
Liner ?ype:
Dianmer: .. inches Dcpth: feet
Casing stickup above ground: 2 feet
Static water level (fi.om ground l~wl): 63 feet
Pumping level: 20'/feet after
_2 hours pmmping _.8 gpm
Recovery Rate: _8 gpm
Method o[Testiug: airlift
Well Intake Opening Type:
[] open [] OpenHo
[] Screened St~r~ f~ Stopped , feet
[] Porforations Stun. , fca Stop[~l
Grout Type: Bentonite # 8 Volume: ~ bg
Depth: · S~rtOfeet Stopped_+ feet
Pump: Intake Depth ... , feet
~:mp size hp Brand Name
Well Dhiufected Upon Completion? [] Yes [-~ No
Method of DiMufection: Clorine Tablets
Comments:
Well Driller:,
Alpine DnTling & Enterprises
P 0 Box 110496
Anchorage AK 99511
well log to the property owner w~h{n 30 days of completion and thc propmy
Received Time Jan.23. 3:01PM
MEMO
TO: Jeff Poet
WITH:
MoA/Bu{Iding Safet3'/On-Site Water & Wastewater Program
DATE:
FROM:
2/12/02
Mike Anderson~'~J/~'4~
SUBJECT:
Lot 8, Block 4, Mountainside Village Subdivision No. 1
Septic System As-Built
Certificate of Health Authority Approval
MESSAGE:
Attached are the completed homeowner's agreement, final electrical inspection
sign-off and copies of the scale tickets Indicating the point of purchase for the
filter sand used in the construction of the bottomless sand filter for the subject
lot.
In addition, the air compressor and in line air gauge have been installed in the
garage serving the house. The air gauge currently reade 2.0 pounds per square
inch. The system t= fully operational at this time. Please lat ,,m~ know If
additional Information is required before the Certificate of Health Authority
Approval can be Issued.
FEB-08-2002 FEI 04:24 PH
h,b-{i.Zf~Ot 01:liPa F;un...$PS#E~.L tk~l$ Ilk;
F~ i'lO. P, 02
- 10?141$1?l T-T31 II.~O~O! F,-14I
SUBSCRIBED AND SWORN to me this llth d_ay of February, 2002.
Pamela lq. l~oodke
lqy Commission Expires 8/21/05
' ~i/~i 'd IG~I'ON flVRn:AI /.ntl? '~ .*]aa
' ' ' ' '" oo'z/co2
1500. S. Tanya Cou~
P 0 BOX 876597
Phone: (g0~)'74~-~2~
F~.x: (907) 746-5226
T~RMS:
DE~.. RIPTION OF wORK AMOUNT
.~..~ , . ,
.." iNvo~c~ .o. ? ~'5'f, 4
15~ S. Tanya~C°u~ - '~
. p.o. aox s~s~7 ~'/" . -~ ~1
Wasltla, Nes~ 99667 ~ ~ '
phone:(90~46'5215 , ' ~'
Fax: (907) 746-5226
To
TERMS:
lABOR
'1
MUNiCIPALITYOFANCHORAGE *
Development Services Department
On-Site Water & Wastewater Prograrn
4700 South Bragaw Street
P.O. Box 196650, Anchorage, AK 99519-6650
(907) 343-7904
ON-SITE WASTEWATER DISPOSAL SYSTEM I WATER SUPPLY PERMIT
Initial
Date Issued: Apr 30, 2001
Expiration Date: Apr 30, 2002
Permit Number: SW010093 Parcel ID: 020-172-49
Legal Description: iMOUNTAINSlDE VILLAGE #1 SUBDIVISION BLOCK 4 LOT 8
Design Engineer: 0014 Anderson Engineering Site Address: 17901 MOUNTAINSIDE VILLAGE DRIVE
Owner Name: HELEN J. ROGERS Lot Size: 54834 SQ. FT.
OwnerAddress: 17901MOUNTAINSlDEVILLAGE DRIVE TotalBedrooms: 4 Permit Bedrooms: 4
ANCHORAGE, A 99516-5735
This permit is for the construction of:
r~ Disposal Field [] Septic Tank [] Holding Tank [] Privy
[] Private Well
[] Water Storage
All construction must be in accordance with:
1. The attached approved design.
2. All requirements specified in Anchorage Municipal Code Chapters 15.55 and 15.65 and the State of Alaska
Wastewater Disposal Regulations ( 18AAC72 ) and Drinking Water Regulations ( 18AAC80 ).
3. The engineer must notify DSD at least 2 hours prior to each inspection. Provide notification by calling
(907) 343-7904 ( 24 hours ). ( Not required for a Water Supply Permit only ).
4. From October 15 to April 15, a subsurface soil absorption system under construction during freezing weather
must be either: A. Open and closed on the same day.
B. Covered, sealed, and heated to prevent freezing.
Received By: ~ ~()~opj~O O-g
Date:_~ - YO -01
ANDERSONENGINEERING
P.O. BOX 240773
ANCHORAGE, AK 99524
522-7773 522-6779 (FAX)
MEMORANDUM
DATE: July 6, 2001
TO:
FROM:
Dan Roth
Mike Anderson, P.E.~
SUBJECT:
Lot 8, Block 4, Mountainside Village Subdivision
Septic System Design Revision
Permit No. SW010093
We have revised the septic system design for the subject lot to include a bottomless
sand filter in lieu of the shallow bed system previously proposed. The sand filter
requires much less surface area and will be more effective in treating the septic effluent
generated in the house. Please review the attached design revisions and modify the
permit for this lot to include the bottomless sand filter.
Thank you for your assistance with this modification and please call if you have any
questions.
TH1
~ 2%
Alternate
Site
TH2 '~
· Sand Filter
~droom
.House
Air Line to be {::
Insulated with ~
,e Wrap Inside a ·
edule 40 PVC Jacket
Minimum Burial
1,'500
STEP Tank
I .25" HDPE Li~e Sloped to
Air. Cdmpressor Shal~
in the Garage. Cot
Provide a 0-10 PSI ~uge
at This Location.
Proposed w~ll
25'
S 62"24'00'~ 160.02'
SITE PLAN
SCALE 1" = 40'
LOT 8, BLO K 4:, M0-1 :I'AiNSIDE VILLAGE
SUBDIVISION
DESIGN FACTORS:
SYSTEM REQUIREMENTS:
4 Bedroom Home
Perc. Rate: 24 Min./Inch
Application Rate: 2 GPDISF
4 Bedrooms X 150 GPD = 600 Gallons Per Day
Bottomless Inter. Sand Filter
1,500 Gallon STEP Tank
2' Coarse Sand (See Spec.)
Air Supply Line (Anch. Tank)
6" of 318" Pea Gravel
600 GPD/2 GPDISF 112 LF (Width of Bed) = 25 LF Length of Bed
Therefore: Construct a Bottomless Intermittent Sand Filter System 12' Wide X 30' Long.
Distribution Piping to be Placed at 3' Below Original Ground Surface. Place 2" of
Insulation Over Bed to Prevent Frost Penetration and Freezing. Backfill Over and Around
New System to Provide Sufficient Cover.
2" ~)irect 'Bury
Insulatioz
12' '1
'PROFII'E VIEW
NOTE:
BO'i-I'OMLESS SAND FILTER DETAIL
(NO SCALE) .~.'~,'~.'t ~.
G~de Area to P=ln Away. ~" .... .~ ~ ~
~. A .~.
Main~In 6' Separation From B~rock. ~:~.' , ~?~ '. ~ ~.
~ ...... ~,-~ .~_~
Maln~ln 4' Sepa~tion From Groundwater. ~.- 4~~ ~*~ ~* 'f
Provide 3' of Cover or 2" Insulation and 2' Cover. ~~.~
G~de Su~ounding Area to Drain Away. ~_'~o~t ~. A~ ~ ~
LOT 8, BLOCK 4, MOUNTAINSIDE VILLAGE
SUBDIVISION
DESIGN FACTORS:
SYSTEM REQUIREMENTS:
4 Bedroom Home
Perc. Rate: 24 MinJlnch
Application Rate: 2 GPD/SF
4 Bedrooms X 150 GPD = 600 Gallons Per Day
Bottomless Inter. Sand Filter
1,500 Gallon STEP Tank
2' Coame Sand (See Spec.)
Air Supply Line (Anch. Tank)
6" of 3/8" Pea Gravel
600 GPD/2 GPDISF 112 LF (Width of Bed) = 25 LF Length of Bed
Therefore: Construct a Bottomless Intermittent Sand Filter System 12' Wide X 30' Long.
Distribution Piping to be Placed at 3' Below Original Ground Surface. Place 2" of
Insulation Over Bed to Prevent Frost Penetration and Freezing. Backfill Over and Around
New System to Provide Sufficient Cover.
NOTE:
(NO SCALE)
Grade Area to Drain Away.
Maintain 6' Separation From Bedrock.
Maintain 4' Separation From Groundwater.
Provide 3' of Cover or 2" Insulation and 2' Cover.
Grade Surrounding Area to Drain Away.
ON-SITE WASTEWATER DISPOSAL SYSTEM
CONSTRUCTION AND MATERIAL SPECIFICATIONS
SUBJECT: LOT 8, BLOCK 4, MOUNTAINSIDE VILLAGE SUBDIVISION
GENERAL:
1. The scope of this project includes the procurement and placement of a
new 1,500 gallon combination septic tank and lift station and pressure
distribution system. Work also includes the construction of a new 30'
long x 12' wide Bottomless Intermittent Sand Filter at the location
shown on the attached Site Plan. A minimum of 2' of coarse sand
meeting the specification from Anchorage Tank must be imported and
placed in the filter area. The 6" of pea gravel and distribution piping
must then be constructed atop the imported filter sand material in
confor~..ance .with specifications furnished by !,he .supplier. The.
distribution piping for the filter must be placed 3 below the original
ground surface at the area shown on the Site Plan to provide a
minimum of 4' separation to groundwater. All work must be completed
in strict conformance with the manufacturer's requirements for
installation of the intermittent sand filter.
Construction shall be in accordance with the approved site plan,
design drawings, Municipal Permit with any special provisions or
conditions, and all applicable State and Municipal Wastewater
Disposal Regulations.
The Contractor shall be responsible for obtaining all underground utility
locates and for the layout of the septic system and verification of the
location of all lot lines.
4. Unless specifically agreed otherwise, the contractor shall be
responsible for final grading areas subsequently depressed from soil
settling. Property owner shall be responsible for revegetation of
affected areas unless specifically agreed otherwise.
5. Contractors installing wastewater disposal systems must be certified
by the Municipal Department of Health and Human Services for
system installations. Owners installing their own systems must receive
pdor approval from D.H.H.S. before beginning system installation.
SEPTIC TANK/LIFT STATION INSTALLATION
1. The 1,500 gallon septic tank/lift station must be constructed by 'a
certified tank manufacturer. Construction shall include an 18" manhole
to provide access to the lift station.
2. The septic tank shall be sufficiently bedded to prevent settling or
shifting of the tank.
3. All standpipes on the septic tank shall extend a minimum of 12 inches
above final grade.
4. Tanks installed without 4' of cover shall have a minimum of 2" of direct
burial insulation.
Lot 8, Block 4, Mountainside Village
July 6, 2001
Page 2 of 3
5. A foundation cleanout shall be installed one to four feet from the
building foundation. Two cleanouts are required between the tank and
the drainfield.
6. Final grading over the tankJiift station shall be such that a positive
slope exists away from the septic tank.
ABSORPTION BED CONSTRUCTION:
The absorption bed shall be constructed to the dimensions shown on
the design. The bottom of the bed shall be within 2" of level.
Distribution piping must be placed level with perforations down atop a
level bed of drainfield rock. Rock should then be placed over the pipe
to provide a minimum of 2" of cover.
A silt barrier or geotextile fabric must be placed between the drainfield
rock and the natural soil backfill.
o
Monitor tubes must be 4" in diameter and installed at the locations
shown on the design. The portion below ground must be perforated.
Contractor shall verify the septic tank and drainfield are a minimum
100' away from any private water wells in the area, 150' from a Class
"C" Well or 200' from any community well.
Direct bury insulation must be placed over the distribution system if
less than 3' of backfill depth is available. Finish grade over the trench
must be mounded to prevent settlement or depressions.
e
Grade area surrounding the absorption trenches to drain away.
A minimum 2' of accepting soil is required below the drainfield rock for
a 5' wide trench. Contractor shall verify this condition prior to
placement of the rock. Ail pockets of unacceptable materials must be
removed and replaced.
MATERIAL SPECIFICATIONS:
The lift station must be constructed by a Municipally approved septic
tank manufacturer. An Orenco 20 OSI 05 HHF-5 pump is
recommended. Anchorage Tank is a recommended supplier for the
materials required for this project.
The following pipe materials are approved for use in septic system
installations in the Municipality of Anchorage:
Cast Iron (perforated and solid) ASTM D3034 or P.V.C. (perforated
and solid) ASTM F810 or H.D.P.E. (perforated, but not solid) and
ASTM D2662 or A.B.S. (perforated and so id).
2. Insulation shall be at least 2" thick extruded direct burial polystyrene
(Dow Chemical Co. Styrofoam HI or equal).
Lot 8, Block 4, Mountainside Village
July 6, 2001
Page 3 of 3
3. Septic tank inlets and outlets shall be fitted with watertight couplings
(Caulder, Femco, or equal).
4. A permeable geotextile fabric (Typar, Mirafi or equal) must be installed
between the final drain rock layer and the native soil layer,
5. All drain reck shall be .5" to 2.5" in diameter with less than 3% passing
the #200 sieve.
EQUIPMENT SPECIFICATIONS:
Air Supply Line shall be a Wasteflow Emitterline, %" inside diameter
from Anchorage Tank. Line shall be insulated with ~" foam pipe wrap
inside a 2" Schedule 40 PVC Jacket buried a minimum 3' below the
surface,
Air Compressor shall be a Thomas Industries Model 5070 as supplied
by Anchorage Tank. Compressor shall be located in the garage or
crawlspace.
A pressure gauge calibrated from 0 to 10 PSI shall be furnished and
installed in line with the air line. The gauge shall be mounted in an
area which provides easy viewing and is seen on a regular basis such
as the entrance to the home.
Material for Filter Sand must meet the following gradation:
50% or More Passing the No. 4 Sieve
2% or Less Passing the No. 100 Sieve
1% or Less Passing the No. 200 Sieve
INSPECTIONS:
A minim, urn of two inspections are required by Municipal Ordinance.
These inspections must be conducted under the supervision of a
prefessional engineer registered in the State of Alaska. The first
inspection must be conducted after the excavation of trenches, beds or
pits and before the installation of any gravel. A septic tank may be set in
place, but may not be backfilled.
The second inspection must be conducted after the placement of the
..geotextile fabric, gravel, distribution piping, standpipes, cleanouts and
insulation. No backfill should be in place at the time of inspection.
Contractor shall provide a copy of all field survey layout and construction
notes for use in preparing the certified as-built of the completed system.
Municipality of Anchorage
Development Services Department
Building Safety Division
On-Site Water and Wastewater Program
4700 South Bragaw St.
P.O. Box 196650 Anchorage. AK 99519-6650
www.ci.anchorage .ak.us
(907) 343-7904
ON-SITE SEWEPJWELL PERMIT APPLICATION
FOR A SINGLE FAMILY DWELLING
Parcel I.D. ~;~_~,_.~_.
Permit Number SWO,/OO?..,,3
I. IELE, V 3;,
Property owner(s) Splnell Homes Day phone 344-5678
Mailing address (1) 92t 0 Vanguard Drive Anchorage~ AK 99507
SITE
Me~,~j-address(2)lTc~OI /~IOU~TR/4,/$1PE. U/Un/s-F. PR. ZipCode
Legal description (Lot, Block & Sub'd.) Lot 8, Block 4, Mountainside Village Subdivision No. t
Legal description (Section, Township & Range)
Lot Size .5'"~[: 8 ~4 Acres(~ Number of Bedrooms Four (4)
THIS APPLICATION IS FOR:
Sewer Only
Sewer and Well
Sewer Upgrade
THIS PROPERTY CONTAINS:
Hot Tub
Swimming Pool
Therapy Pool
I'"] Well Only [-I
[] Water Storage []
Jacuzzi
Water Softening Unit
I certify that the above information is correct. I further certify that this application is being made for a
Single Family Dwelling and is in accordance with applicable Municipal Codes.
(Signature of property owner or authorized agent)
Permit Fees:~'J~'~
Date of Payment: ~..~o ~t ~'(~/
Receipt Number: ~
(Rev. 12/00)
Waiver Fees:
Date of Payment:
Receipt Number:
ANDERSONENGINEERING,, '
P.O: BOX 240773
ANCHOIL:iAGE~, AK 99524
522,777~: 522-6779 (FAX)
April19,2001
Municipality of Anchorage
Development Services Department
On-Site Water and Wastewater Program
4700 South Bragaw Street
Anchorage, AK 99519-6650
Subject:
Lot 8, Block 4, Mountainside Village Subdivision No. 1
Septic System Design and Permit Application
Impacts to Adjacent Properties
Dear Onsite Services Engineer:.
The owner of Lot 8, Block 4, Mountainside Village Subdivision intends to place a new 4-
bedroom home on the lot. We are therefore applying for a permit to construct a new
well and sept c system on the lot to serve the proposed home. The attached Site Plan
and backup documentation identify the location a.nd configuration of the new well and
sept c system and the parameters used in the design. It also shows the location of the
test holes and the alternate septic site. Existing drainage patterns are shown and w
not be altered by the development of the lot.
Two test holes were placed at the prop..o, sed location for the new and alternate
absorption beds and revealed gravel w~th varying amounts of silt up to 25%.
Groundwater was noted in the test holes during excavation at 8' and 9' and remained at
those eve s durin~ the monitoring period. The soil percolated at a rate of 24 minutes
per inch. We are~herefore proposing !o place 2 absorption beds each 50' long by 15'
wide to treat the septic effluent. The p pe will be placed at 3 below the existing ground
surface and the total depth of the beds will be 3.5'. Some coarse sand may be required
to level the beds. A minimum of 3' of cover will be placed over the bed to prevent frost
penetration and possible freezing. A Zabel flow splitter will be placed to insure even
flow from the septic tank to the beds.
The ground surface on the lot slopes as shown on the attached Site Plan with 2% to 5%
grades from east to west near the northern portion of the lot. The slope becomes flatter
proceeding west and slopes to, the stream flowing through the property at the west
property line. The new beds w~ll be, constructed parallel t.o. the contours of the surface
~n conformance with Municipal requirements. Grading w~ll be accomplished to assure
su. rface drainage is aw. ay from the new beds. The existing drainage pattern on the lot
w~ll not be affected dunng development.
If the system is constructed In accordance with our design the following statements
apply:
The system, if constructed as designed, will have no adverse impact on the wells
Lot 8, Block 4, Mountainside Village Subdivision
April 19, 2001
Page Two
e
in the area or those to be constructed in the future.
The system, if constructed as designed, will have no adverse impact on existing
septic systems in the area or those to be constructed in the future.
The system, If constructed as designed, will have no adverse impact on reserve
space, either surface or subsurface, on any lots located in the area.
The system, if constructed as designed, will have no adverse impact on drainage
patterns in the area. The current drainage pattern will be maintained.
Sincerely,
Michael E. Anderson, P.E.
Attachments
/5,
/6'
//
/O
AREA MAP '....
/O
-4381
/7
TH2 ®
TH1
2%
250 Gallon ·
)tic Tank
Fou~ xl~4.
Bedroom
.House
Alternate
Site
100' SEPTIC ~-iuACK
_~_ Proposed will
SITE 'PLAN
SCALE 1" = 40'
MICHAEL E.
CE - 438 J
LOT 8, BLOCK 4, MOUNTAINSIDE VILLAGE
ABSORPTION BED
DESIGN FACTORS:
SYSTEM REQUIREMENTS:
4 Bedroom Home
Peru. Rate: 24 MinJlnch
Application Rate: .4 GPDISF
Shallow Bed System
1~50 Gallon Septic Tank
1' Total Drain Field Rock
4 Bedrooms X 150 GPD 1.4 App. Factor = '1,500 Square Feet
1,500 SFI15 LF (Width of Bed) = 100 LF Length of Bed
"therefore: Construct Two Absorption Beds Each 50' in Length by 15' Wide. Bottom of
Distribution Piping to be 3' Below Existing Grade. Total Depth of Bed to be 3.5' Below
Existing Grade. Level Bottom of Bed with Coarse Sand Prior to Placement of Drain Field
Rock. Mound Over Bed to Provide 3' Minimum Cover to Prevent Frost Penetration. Place
Zabel Flow Splitter Valve to Assure Even Flow of Effluent to Each Bed.
As
Req'd
2' Natural Backfill Cover.
(Minimum)
2" I~sulation.o~ ~' Cover'
Coarse Sand to Level Bottom of ~ed
'(As Necessary)
~ld Rock
NOTE:
SHALLOW BED DETAIL
(NO SCALE)
Grade Area to Drain Away.
Maintain 6' Separation From Bedrock.
Provide 3' of Cover or 2" Insulation and 2' Cover.
Maintain 4' Separation From Groundwater.
Maintain 100' Separation From Well.
Performed For:
Legal Description:
2
3
4
1
11
12
13
14
15
16
17
18
PTIOL
WATER
3/22/01
BoTroM
OF HOLE
Municipality of Anchorage
Development Services Department
4700- S. Bragraw, Anchorage, AK 99507
SOILS LOG - PERCOLATION TEST
Spinne, Homes Date Performed:
Lot 8, Block 4, Mountainside Village Subd.
Testhole Number 2
.LOPE SITE PLAN
2%
See SitePlan
Was Groundwater
Encountered? Yes
If Yes, What Depth? 8'
Depth to Water
After Monitoring 8 '
Date: 4~ 1
W 2%
Reading Date Gross Net Depth To Net
Time Time ~/ater Drop
I 22-Mar 10:55 1.25'
2 11:25 30 2.5" 1.25"
3 11:55 30 3.75" 1.25'
4 11:56 1.5"
5 12:26 30 2.75" 1.25"
Perc. Rate: 24 Min./Inch Perc. Hole Diameter: 6"
Test Run Between 5 Ft. and 6 Ft.
Comments: Testhole Presoaked Prior to Percolation Test.
Performed By: Tim Kimbrouah I, ~ Certify That This Test Was Performed
In Accordance With All State and Municipal Guidelines In Effect On This Date: ~- I ~ "O I
Performed For:
Legal Description:
3
4
5
6
1
11
12
14
15
16
17
18
PWOL
,1,
SOILS LOG - PERCOLATION TEST ~ ~;~'~ -~.' ;DEESC. N .~ ~
Spinnell Homes Date Perfofl"Jg~.:o, 3/22/0.1,.'~-~~'
Lot 8, Bl~k 4, Mountainside Village Subd. *l I? ~,~ ;~A~
SLOPE SITE P~Ntt~~
%N
Testhole Number I
See Site Plan
WATER
3~01
Was Groundwater
Encountered? Yes
If Yes, What Depth? 9'
Depth to Water 9 '
After Monitoring
Date: 4~"~7'01
S
L~/
O
2%
BOTTOM
OF HOLE
Reading Date Gross Net Depth To Net
rime Time Water Drop
I 22-Mar 10:45 1.25'
2 11:15 30 2.5" 1.25"
3 11:45 30 3.75' 1.25"
4 11:46 1.5"
5 12:16 30 2.75" 1.25"
Perc. Rate: 24 Min./Inch Perc. Hole Diameter: 6"
Test Run Between 4.5 Ft. and 5.5 Ft.
Comments: Testhole Presoaked Prior to Percolation Test.
Performed By: Tim Kimbrouah. I, ~ Certify That This Test Was Performed
In Accordance With All State and Municipal Guidelines In Effect On This Date: q'--! ~" 0 1
ON-SITE WASTEWATER DISPOSAL SYSTEM
CONSTRUCTION AND MATERIAL SPECIFICATIONS
SUBJECT: LOT 8, BLOCK 4, MOUNTAINSIDE VILLAGE SUBDIVISION
GENERAL:
The scope of this project includes the procurement and placement of a
new 1,250 gallon septic tank at the location shown on the site plan.
Work also includes the construction of 2 new 50' long X 15' wide
absorption beds at the location shown. The distribution line in the
beds will be placed at 3' below the existing ground surface. Coarse
sand may be required to level the beds. In addition, a Zabel Flow
Splitter Valve must be placed to insure even flow from the septic tank
to each bed. Total depth of the beds will be 3.5' below the existing
ground surface. All components of the septic system must be placed a
minimum of 100' from the well on the lot.
Construction shall be in accordance with the approved site plan,
design drawings, Municipal Permit with any special provisions or
conditions, and all applicable State and Municipal Wastewater
Disposal Regulations.
The Contractor shall be responsible for obtaining all underground utility
locates and for the layout of the septic system and verification of the
location of all lot lines.
Unless specifically agreed otherwise, the contractor shall be
responsible for final grading areas subsequently depressed from soil
settling. Property owner shall be responsible for revegetation of
affected areas unless specifically agreed otherwise.
Contractors installing wastewater disposal systems must be certified
by the Municipal Department of Health and Human Services for
system installations. Owners installing their own systems must receive
prior approval from D.H.H.S. before beginning system installation.
SEPTIC TANK INSTALLATION
1. A new 1,250 gallon septic tank must be be procured from an approved
source and installed at the location shown.
A septic tank is to be constructed by a certified septic tank
manufacturer. Construction shall include two 4" cleanouts for pumping
access.
The septic tank shall be sufficiently bedded to prevent settling or
shifting of the tank.
All standpipes on the septic tank shall extend a minimum of 12 inches
above final grade.
Tanks installed without 4' of cover shall have a minimum of 2" of direct
burial insulation.
Lot 8, Block 4,Mountainside Village Subdivision
April 19, 2001
Page 2 of 3
6. A foundation cleanout shall be installed one to four feet from the
building foundation. Two cleanouts are required between the tank and
the drainfield.
7, Final grading over the tank shall be such that a positive slope exists
away from the septic tank.
DRAINFIELD CONSTRUCTION:
The drainfield shall be constructed to the dimensions shown on the
design. The bottom of the bed shall be within 2" of level.
Distribution piping must be placed level with perforations down ato.p a
level bed of drainfield rock. Rock should then be placed over the p~pe
to provide a minimum of 2" of cover.
A silt barrier or geotextile fabric must be placed between the drainfleld
rock and the natural soil backfill.
Monitor tubes must be 4" in diameter and installed at the locations
shown on the design. The portion below ground must be perforated,
Contractor shall vedfy the septic tank and drainfield are a minimum
100' away from any private water wells in the area, 150' from a Class
"C" Well or 200' from any community well.
Direct bury insulation must be placed over the distribution system if
less than 3' of backfill depth is available. Finish grade over the trench
must be mounded to prevent settlement or depressions.
Grade area surrounding the absorption beds to drain away.
A minimum 2' of accepting soil is required below the drainfield rock for
a 5' wide trench. Contractor shall verify this condition prior to
placement of the rock. All pockets of unacceptable materials must be
removed and replaced.
MATERIAL SPECIFICATIONS:
1. Septic tanks must be constructed by a municipally approved septic
tank manufacturer.
2. The following pipe materials are approved for use in septic system
installations in the Municipality of Anchorage:
Cast Iron (perforated and solid) ASTM D3034 or P.V.C. (perforated
and solid), ASTM F810 or H.D.P.E. (perforated, but not solid) and
ASTM D2662 or A.B.S. (perforated and solid).
3. Insulation shall be at least 2" thick extruded direct burial polystyrene
(Dow Chemical Co. Styrofoam HI or equal).
4. Septic tank inlets and outlets shall be fitted with watertight couplings
(Caulder, Femco, or equal).
Lot 8, Block 4,Mountainslde Village Subdivision
April 19, 2001
Page 3 of 3
5. A permeable geotextile fabric (Typar, Mirafi or equal) must be installed
between the final drain rock layer and the native soil layer,
6. All drain rock shall be .5" to 2.5" in diameter with less than 3% passing
the #200 sieve.
INSPECTIONS:
Municipal Ordinance requires a minimum of two inspections. These
inspections must be conducted under the supervision of a professional
engineer registered in the State of Alaska. The first inspection must be
conducted after the excavation of trenches, beds or pits and before the
installation of any gravel. A septic tank may be set in place, but may not
be backfilled.
The second inspection must be conducted after the placement of the
geotextile fabric, gravel, distribution piping, standpipes, cleanouts and
insulation. No backfill should be in place at the time of inspection.
Contractor shall provide a copy of all field survey layout and construction
notes for use in preparing the certified as-built of the completed system.
Municipality of Anchorage
Development Services Department
Building Safety Division
On-Site Water and Wastewater Program
4700 South Bragaw St.
P.O. Box 196650 Anchorage, AK 99519-6650
www.ci.anchorage.ak.us
(907) 343-7904
CERTIFICATE Of HEALTH AUTHORITY APPROVAL
FOR A SINGLE FAMILY DWELLING
Parcel I.D. 020-172-49
1. GENERAL INFORMATION
Complete legal description'
Expiration Date:
Lot 8. Block 4, Mountainside Villa.qe Subdivision No. 1
Location (site address er directions) Mountainside Villaqe Drive near Wolf Creek Drive
Current Property owner(s) Spinell Homes
Day phone 344-5678
Mailing address
92t0 Van.quard Drive Anchora.qe, AK 99507
Lending agency
Day phone
Mailing address
Real Estate Agent
Day phone
Mailing Address
Unless other, vise requested, HAA will be held by DSD for pickup.
2. NUMBER OF BEDROOMS: Four(4)
3. TYPE OF WATER SUPPLY:
Individual Well []
Individual Water Storage [--I
· Community'Class .... Well []
Public Water System []
· TYPE OF WASTEWATER DISPOSAL:
Individual On-site []
Individual Holding tank []
Community On-site []
Public Sewer []
The Municipality of Anchorage Development Services Depadment (DSD) Issues Cedificates of Health Authority
Approval (HAA) based only upon the representations given in paragraph 5 by an independent professional civil
engineer registered in the State of Alaska. Certificates of Health Authority Approval are required for the transfer of
title (except be[ween spouses) for properties served by a sing!e fatuity on-site wastewater dispccal and/ct water
supply system. DSD also issues HAAs upon request to homeowners. Certificates of Health Authority Approval are
valid for 90 days from the date of issue for properties served by a pdvate or Class C well and may be reissued with
new water sample results less than 30 days old. (Certificates may be reissued for a period of up to one year with
valid water samples.) Certificates are valid for one year for properties served by Class A or B welIs or a public
~vatar system. The Municipality of Anchorage is not responsible for errors or omissions in the professional
engineer's work.
4. STATEMENT OF INSPECTION BY ENGINEER
As certified by my seal affixed hereto and as of the validation date shown below, I verify that my investigation,
based on procedures outlined in Ihe Health Authority Approval Guidelines for this application, shows that the
on-site water supply and/or wastewater disposal system is(ara) safe, functional and adequate for the number of
bedrooms and type of structure indicated herein. I further verify that based on the information obtained from the
Municipality of Anchorage flies and from my investigation and inspection, the on-site water supply and/or
wastewater disposal system is(ara) in compliance with all applicable Municipal and State codes, ordinances,
and regulations in effect at the time of installation.
Name of Firm Anderson Enqineerinq
Address P.O. Box 240773 Anchoraqe~AK 99524
Engineerls Printed Name Michael E. Anderson, P.E,
5. DSD SIGNATURE
~ Approved for ~
Disapproved.
Conditional approval for
bedrooms.
Phone 522.7T'/3
Date 1/23/02
~;.-
bedrooms, with the following stipulations:
Additional Comments
Attachments:
HAA Checklist
Septic System Advisory
Well Flow Advisory
X
Maintenance Agreements
Supplemental Engineer's Report
Other
(Rev. l?JOO)
Original Cedificate Date: .;~. - / ~ - o -1
Municipality of Anchorage
Development Services Department
Building Safety Division
On-Site Water & Wastewatar Program
470O South Bragaw St.
P.O. Box 196650 Anchorage. AK 99519-6650
www.ci.anchorage.ak.us
(907) 343-7904
HEALTH AUTHORITY APPROVAL CHECKLIST
Legal ~pfion: Lot 8, Block 4, Mountainside VIIla.qe Subdivision No. 1
Parcel ID:
A. WELL DATA
Wadi type Private
flA. B. or C provide PWSID #
wea Lng (Y/N) Y
Date completed 7/26/;D01
Total depth 207 It.
Date of test
Static water level 63
Wea production 8
WATER SAMPLE RESULTS:
Cetiferm 0 colonies/100 mL
Date of sample: t/21/2002
SEPTIC/HOLDING TANK DATA
Tank Type/Material STEP/Stesl
Sanitary seal (Y/N) Y
Cesed to 7/ It.
FROM WELL LO.G
7/26/2001
g.p.m.
Nitrate 1.26 mgJL
Collected by: UFA
W~res properly I~otected (Y/N) Y
Casing height (above ground) 24'
AT INSPECTION
iN.
It*
g.p.m.
Date installed ~tlSr~X~l
Tank size 1,.gXl gal.
Foundation clsanout (Y/N) Y
Date of pumping
C. ABSORPTION FLEE) DATA
Number of Compartments
Pumper
Soil rating (g.p.dJit2 or ~rodrm) 2 GPD/SF
fl. Width 12 It.
~,e~ (Y/N) v
High water alarm (Y/N) Y
System type Bottomless Sand Filter
Gravel beJow pipe .~, ft.
Total depth _6 It.
Data of adequacy test Restdta (Pass/Fail)
Fluid depth in absorption field before test __ in. Water added gal.
Elapsed T~ne: min. Final fluid depth in. Absorption rate >=
Any rejuvenation treatment (past 12 mo.) (Y/N & type) N If yes. give date
Eft. absorption area 360 It2 Monitoring tube Y Depression over field N
For bedrooms
New depth in.
g.p.d.
D. UFT STATION
Date installed 8/18/2001
'Pump on' level at 43 in.
Datum Bottom of Tank
E. SEPARATION DISTANCES
Size in .gallons .250
'Pump off' level at 43 in.
Cycles tested New Conot.
SEPARATION DISTANCES FROM WELL ON LOT TO:
Septic tankA~ station on lot. >100'
Absorption field on lot >100'
Public sewer main
Sewer/septic service line >25'
Manhele/Access (Y/N) Y
High water alarm level at 45
Meets alarm & circuit requirements? Y
in.
On adjacent lots >100'
On adjacent lots >t00'
· Public sewer manhele/cleaneut N/A
Holding tank N/A
SEPARATION DISTANCES FROM SEPTIC/HOLDING TANK ON LOT TO:
Building foundation >5'
Water main N/A
Wells on adjacent lots >100'
SEPARATION DISTANCE FROM ABSORPTION FIELD ON LOT TO:
Property line >10'
Water Sewine line >t0'
Curtain drain None Noted
F. COMMENTS
Property line >5'
Water service line >10'
Building foundation >10'
Surface water >100'
Wells on adjacent lots >100'
G. ENGINEER'S CERTIFICATION
I ce~t~y that I have deterrn~ed through fie/d inspecUons and
rmdew of Municipal records that the above systems are in
conformance with MOA HAA guidelines in effect on this date.
"E~gi~er'S Printed Name Michael E Anderson, P.F_
Data t/23/01
HAA Fee $
Date of Payment
Receipt Number
(Rev. 12/00)
Absorption field >5'
Surface water >100'
Water main >10'
Driveway, pa~g~veh~e storage >25'
=
.....
Wa~ F~ $
Data ~ ~t
~pt Num~
JAN-23-OZ 09:30A~ FROgI-CT&E ENVIRON~NTAt. SRV
,~f~_,, CT&E Environmental
Services
thc.
9075515301
T-799 P.0Z/02 F-055
C'I'AE ITc f.#
Client Neme
Project Name J#
Client Sample ID
Ordered By
PWSID
Snmplc Rcmarks:
1020392001
Ander~on~,~ngineerlng
Lot 8 BIkl Mountainside
Lot 8 Blk~l Mountainside
Drinking Water
0
Results
PQL
Units Method
Client PO#
Printed Date/Time 01/22/2002 19:44
Coltocted Date/Time 01/21/2002 10:30
Received Date/Time 01/21/2002 10:55
T~chnical Director · Stephen C. £de
Released B~~ ~
Allowable pzcp Analysls
Limits Date Date Init
T',litratc-N
1.26
0.200 mg/L EPA 300.0 (<10) 01/2t/02 IDT .
~ ~robAoloov ~abora~orv
Total Coliform
col/1O0mL SMI8 9222B
(<1) 01/21/02 g. AP
Received TiJe Jan.23. 9:33AM