Loading...
HomeMy WebLinkAboutSKYHILLS PH 3 BLK 3 LT 305kyhills Block 3 Lot 30 #011-122-62 Municipality of Anchorage Page t of 4 Department of Health and Human Services Division of Environmental Services On-Site Services Section 825 'L' Street Room 502 P.O. Box 196650 Anchorage, AK 99519-6650 www.ci.anchorageak.us (907) 343-.4744 ON-SITE WASTEWATER DISPOSAL SYSTEM AND/OR WELL INSPECTION REPORT Permit Number: SW010164 PID Number:. 011-122-62 The Petersen Group, Inc, Wastewater System: New 3820 Lake Otis Pkwy., Suite 204 Anch., AK 99508 ABSORPTION FIELD 562.1170 Four {4) Deep Trench LEGAL DESCRIPTION 12 GP~e 12 3 30 Skyhills No. 3 5 F,. 7 0 ~,. 41 Well: Publlc Water 3 r,. F~. ~,.574 re ASTM D3034 PVC F, Sanders & Sanders 6/26/01 SEPARATION DISTANCES Ig septic D Holding D S.T.E.P. [] Othen Tank Field Station Tank ~ [~e Anchorage Tank 1,250 w~ N/A NIA N/A NIA N/A Steel Two (2) s~.w.,, ·100' ·100' N/A NIA ~ / LIFT STATION - NONE ON LOT t~,~ >5' >10' NIA NIA >5' ·10' N/A NIA c~. ~. None Noted "~ ~ ~ ~ ~ ~"'*~' n,~,,, BENCH MARK Garage Floor Slab Inspections performed by: MEA Dates: 1" 6/26/01 2"~ 6/26101 Department of Health and Human Services approval ~.C~-. CE.4381 .° ! / / / Municipality of Anchorage DEVELOPMENT SERVICES DEPARTMENT 4700 South Bragaw Street Anchorage, AK 99519-6650 - 343.7904 On-Site Wastewater Disposal System or Well Inspection Report Page 2 of 3 Permit Number SW010164 PID No. 011-122-62 THA ' / FOUR BEDROOM. HOUSE A B Sl 13.5 15.9 S2 12.2 22.2 , C4 53.1 67.3 MI 53.4 67.6 C5 38.5 41.5 LOT 30 PLAN AS-BUILT SCALE 1" =40' · Municipality of Anchorage DEVEOPMENT SERVICES DEPARTMENT 4700 South Bragaw Street Anchorage, AK. 99519-6655 - 343-7904 On-Site Wastewater Disposal System or Well Inspection Report Permit Number:. SW010164 Page 3 of 3 PID No.: 011-122-62 n_ 13' 100.7~ ~ o 95.3-./ 93.3 99.0 PROFILE AS-BUILT Scole: 1" m 10' MEMO TO: Jeff Post WITH: MoA/Building Safety/On.Site Water & Wastewater Program DATE: FROM: 2119102 Mike Andemon~ SUBJECT: Lot 30, Block s, Skyhill$ Subdivision No. 3 Septic System As-Built Certificate of Health Authority Approval MESSAGE: The absorption trench serving the ssptic system on Lot 30, Block 3, Skyhills No. 3 was placed parallel with ths lot line to provide more room for the construction of the house on the lot. The lot topography is virtually fiat in the area of the new trench which would allow placement in either dirsction. We Inspected the area prior to construction o! the trench and verified little or no drop over the surface of the lot In the area of the absorption trench. Please let me know if additional information is required before the Certificate of Health Authority Approval can be issued. 1 "=40' I ! / ! ! SKYHILLS SUBD., PHASE ,3 LOT 30, BLOCK 3 40,041 S.F. LOT 30 , AS-BU ILT · ' JD'F A. OASTALDI, R~L$. 4726 WEST 881H AVE:NI,~ N~ICHORAGE, N.A~KA 99502 PHONE 2222 I/~1/20o2 F.8. ,JOB. NO. 01-08 . $i-rS3303 MUNICIPALITY OF ANCHORAGE Development Sen/ices Department On-Site Water & Wastewater Program 4700 South Bragaw Street P.O. Box 196650, Anchorage, AK 99519-6650 (907) 343-7904 ON-SITE WASTEWATER DISPOSAL SYSTEM PERMIT Initial Date Issued: Jun 05, 2001 Expiration Date: Jun 05, 2002 Permit Number: SW010164 ,Legal Description: SKYHILLS PH 3 BLK 3 LT 30 Design Engineer: 0014 Anderson Engineering Owner Name: DAVID EIBECK Owner Address: 8301 SKY MOUNTAIN CIRCLE ANCHORAGE, AK 99516- Parcel ID: 011-122-62 Site Address: Lot Size: 40041 SQ. FT. Total Bedrooms: 4 Permit Bedrooms: 4 This permit is for the construction of: [] Disposal Field [] Septic Tank [] Holding Tank [] Privy [] Private Well [] Water Storage Ail construction must be in accordance with: 1. The attached approved design. 2. All requirements specified in Anchorage Municipal Code Chapters 15.55 and 15.65 and the State of Alaska Wastawater Disposal Regulations ( 18AAC72 ) and Drinking Water Regulations ( 18AAC80 ). 3. The engineer must notify DSD at least 2 hours prior to each inspection. Provide notification by calling (907) 343-7904 ( 24 hours ). ( Not required for a Water Supply Permit only ). 4. From October 15 to April 15, a subsurface soil absorption system under construction during freezing weather must be either: A. Open and closed on the same day. B. Covered, sealed, and heated to prevent freezing. Received By: ~ Issued By: ~ Date: Data: Municipality of Anchorage Development SerVices Department Building Safety Division On-Site Water and Wastewater Program 4700 South Bragaw St. P.O. Box 196650 Anchorage, AK 995196650 www.ci.anchorage.ak.us (907) 343-7904 ON-SITE SEWER/VVELL PERMIT APPLICATION FOR A SINGLE FAMILY DWELLING Permit Number SW O l O I g~t Property owner(s) 1'he Petersen Group, Inc. Mailing address (1) 3820 Lake Otis Parkway~ Suite 204 Anchorage~ AK 99508 ...... :,-,§ address (2) 8~0] ~(Y ~OU~T/tI~ Cl~ Day phone 502.t170 Zip Code ~'~1~ Legal description (Lot, Block & Sub'd.) Lot 30, Block 3, Skyhills Subdivlslon No. 3 Legal description (Section, Township & Range) Lot Size 40,041 SF AcreslSq. Ft. Number of Bedrooms Four (4) THIS APPLICATION IS FOR: Sewer Only Sewer and Well Sewer Upgrade THIS PROPERTY CONTAINS: Hot Tub Swimming Pool Therapy Pool [] Well Only Water Storage Jacuzzi Water Softening Unit I cedify that the above information is correct. I further cedifythat this application is being made for a Single Family Dwelling and is in accordance with applicable Municipal Codes. (Signature of property owner or authorized agent) Permit Fees: Date of Payment: Receipt Number: '~,~) (Rev. 12~00) Waiver Fees: Date of Payment: Receipt Number: ANDERSON ENGINEERING P.O. BOX 240773 ANCHORAGE, AK 99524 522-7773 522-6779 (FAX) MEMORANDUM DATE: June 4, 2001 TO: FROM: Dan Roth Mike Anderson, P.E~ SUBJECT: Lot 30, Block 3, Skyhills No. 3 Septic System Design and Permit Application I have revised the design for the proposed septic system for Lot 30, Block 3, Skyhills No. 3 to reflect placement of the absorption trench beneath the fill and organic material on the lot. Please review the revisions and if acceptable issue the permit for construction of the new septic system. May 14,2001 Municipality of Anchorage Development Services Department On-Site Water and Wastewater Program 4700 South Bragaw Street Anchorage, AK 99519-6650 Subject: Lot 30, Block 3, Skyhills Subdivision No. 3 Septic System Design and Permit Application Impacts to Adjacent Properties Dear Onsite Services Engineer:. The owner of Lot 30, Block 3, Skyhills Subdivision No. 3 intends to place a new 4- bedroom home on the lot. We are therefore applying for a permit to construct a new septic system on the lot to serve the proposed home. The subdivision is Currently served by the Municipal water system. The attached Site Plan and backup documentation id .entify the location and configuration of the new septic system and the parameters used n the des gn It also shows the location of the new water service line.. Also identified are the location of the test holes and the alternate septic site. Existing drainage patterns are shown and will not be altered by the development of the lot. Two test holes were placed on the lot during the fall of 1999. Soils were found to be well to poorly graded sands with minor amounts of silt. Percolation tests in the material indicated rates between 2 and 3 minutes per inch which is consistent with the rates · achieved on the lots surrounding this lot. No groundwater was found during the excavation and none was found during the monitoring period. We are therefore proposing to place an absorption trench 40' long by 3' wide with a 7' effective depth to treat the septic effluent. The distribution pipe will be placed at 5' below the surface for a total depth of 12'. The trench will be placed under the fill and organic material on the lot which extends to nearly 5' below the surface. The ground surface on the lot slopes as shown on the attached Site Plan with slight grades from we.s.t to east. A steep bluff is found at the easterly portio.n of the lot. The septic system w~ll be constructed a minimum of 50' from the edge of th~s bluff. The new absorption trench will be constructed parallel to the contours of the surface in conformance with Municipal requirements. Grading will be accomplished to assure surface drainage is away from the new trench. The existing drainage pattern on the lot will not be affected during development. If the system is constructed in accordance with our design the following statements apply: 1. The system, if constructed as designed, will have no adverse impact on the wells Lot 30, Block 3, Skyhills Subdivision No. 3 May 14, 2001 Page Two in the area or those to be constructed in the future. The subdivision is currently served by the Municipal water system. 2. The system, if c. onstructed as designed will have no.adverse impact on existing septic systems in the area or those to be constructed m the future. 4. Sincerely, The system, If constructed as designed, will have no adverse impact on reserve space, either surface or subsurface, on any lots located in the area. The system, if constructed as designed, will have no adverse impact on drainage patterns in the area. The current drainage pattern will be maintained. Michael E. Anderson, P.E. Attachments · 'N COURT ..... ..... "'-.. / 4 : 5 42.401 sq. fL 7 SKY'HILLS '10 40.182 33 31 40..350 ~q. fL ~8-3-A 28:' N89'~3'28'£ 768.34'(R) 174,12' .... J LOT 30, BLOCK 3, SKYHILLS SUBDIVISION PHASE 3 ~ Alterna ~O~/ THA Line,, THB Four' Bedrdom . Home NOTE: Maintain 10' Separa[z~ Between Water Service and Ail Components of Septic System. Depth ./ SITE PLAN SCALE1"=40' LOT 30, BLOCK 3, SKYHILLS SUBDIVISION NO. 3 DESIGN FACTORS: SYSTEM REQUIREMENTS: Four Bedroom Home Perc. Rate: 2-3 Min./Inch Application Rate: 1.2 GPD/SF Deep Trench System 1,250 Gallon Septic Tank 7' Drain Field Rock 4 Bedrooms X 150 GPD 11.2 GPDISF = 500 SF of Absorption Area 500 SFI14SF/LF = 35.7 LF Trench Length Therefore: Construct an Absorption Trench 40' in Length by 3' Wide With 7' of Drainfield Rock Beneath the Distribution Lateral. Distribution Lateral to Be Placed 5' Below Existing Ground. Total Depth of Trench to Be 12' from Existing Surface. Mound Over Trench if Necessary to Provide Minimum Cover of 3'. NOTE: TYPICAL DEEP TRENCH SECTION _-"?~-Y.'" -- (NO SCALE~ -- -- '~ ~ ~." 4 Grade Area ~er Trench to D~,n Away. ,' .... ' ...... Minimum 6 Sepamtlo. From B~r~k. - '~~-~N · Mmlmum 10 Sepa~flon ~ro~ Lot Line. ~ Minimum 4' Se~tion From Groundwater. Performed For:. Bob Klein Legal Description: Lot 30. Block 3 Sk_v Hills Phase III SLOPE 6 8 9 10 11 12 13 14 15 16 17 18 19 Fill Area GM Debris · ,~; OF AL~:' ,-~/',~" ..... ;"~G','. Munlclpah~ of Ancho~ge Depa~ment of Health & Human Sewices ~'.'~_[~7;E~ [ ~;O~,~" :~ ~ 825 L S~t. Anchorage. AK 99502~650 ~ ~ .. CE - 4381 ..,~- ~ SOILS LOG - PERCO~ON TEST 4~. ~¢?.. .." %~ ~ Date Pedo~ed: ~ I~~ OG/PT Fine Sand Some Silt Bottom of Hole No SITE PLAN 2% - 5% None 10110199 Was Groundwater Encountered? If Yet, What Depth? SP Depth to Water After Monitoring Date: Reading Date Gross Net Depth To Net Time Time Water :Drop I 29-Sap 13:06 .5" 2 13:16 10 3.5" 3" 3 13:17 .5" 4 13:27 10 3.5" 3" 5 13:28 - .25" 6 13:38 10 3.25' 3" Parc. Rate: 3.3 MinJlnch Parc. Hole Diameter: 6" Test Run Between 6 Ft. and 7 Ft. Comments: Percolation Cavity Presoaked Prior to Testing. Performed By: ~ I, MJ~3acLE-~3d~D~ Certify That This Test Was Performed In Accordance With All State and Municipal Guidelines In Effect On This Date: 10/25/99 Performed For: Bob Klein Legal Description: Lot 30. Bl~ck 3 Sky Hills. Phase I1! SLOPE ........ ~umc~pa.~ o~ anchorage ~ ~.~.~- · Depa~ment of Health & Human Se~s 825 L Skit. Anchor~o. SOILS LOG - PERCO~ON ~ST Date Petered: ~/~~ S~E P~ 1 11 12 13 14 15 16 17 18 Fill Area GM Debris OG/PT Fine Sand Some Silt SP Was Groundwater Encountered? No S If Yet, What Depth? L Depth to Water O After Monitoring None P Date: 10/10/99 E 2% - 5% Reading Date Gross Net Depth To Net Time Time I/Vater Drop I 29-Sep 14:10 .5" 2 14:20 10 5.5" 5" 3 14:21 .5' 4 14:31 10 5.5" 5" 5 14:32 .25" 6 14:42 10 5.25' 5' Bottom of Hole Perc. Rate: 2 Min./Inch Perc. Hole Diameter: 6" Test Run Between 6 Ft. and 7 Ft. ' Comments: Percolation Cavity Presoaked Pdor to Testing. Performed By: ~ I, ~ Certify That This Test Was Performed In Accordance With All State and Municipal Guidelines In Effect On This Date: 10/25/99 ON-SITE WASTEWATER DISPOSAL SYSTEM CONSTRUCTION AND MATERIAL SPECIFICATIONS SUBJECT: LOT 30, BLOCK 3, SKYHILLS SUBDIVISION NO. 3 GENERAL: The scope of lhis project includes the procurement and placement of a new 1,250 gallon septic tank at the location shown on the site plan. Work also includes the construction of a new 40' long X 3' wide X 7' effective depth absorption trench at the location shown. The distribution line in the trench will be placed at 5' below the existing ground surface. Total depth of the trench will be 12' below the existing ground surface. All components of the septic system must be placed a minimum of 10' from the water service line to be constructed on the lot. Construction shall be in accordance with the approved site plan, design drawings, Municipal Permit with any special provisions or conditions, and all applicable. State and Municipal Wastewater Disposal Regulations. The Contractor shall be responsible for obtaining all underground utility locates and for the layout of the septic system and verification of the location of all lot lines. Unless specifically agreed otherwise, the contractor shall be responsible for final grading areas subsequently depressed from soil settling. Property owner shall be responsible for revegetation of affected areas unless specifically agreed otherwise. Contractors installing wastewater disposal systems must be certified by the Municipal Department of Health and Human Services for system installations. Owners installing their own systems must receive pdor approval from D.H.H.S. before beginning system installation. SEPTIC TANK INSTALLATION 1. A new 1,250 gallon septic tank must be be procured from an approved source and installed at the location shown. A septic tank is to be constructed by a certified septic tank manufacturer. Construction shall include two 4' cleanouts for pumping access. 3. The septic tank shall be sufficiently bedded to prevent settling or shifting of the tank. 4. All standpipes on the septic tank shall extend a minimum of 12 inches above final grade. 5. Tanks installed without 4' of cover shall have a minimum of 2" of direct burial insulation. A foundation cleanout shall be installed one to four feet from the building foundation. Two cleanouts are required between the tank and the drainfield. * Lot 30, Block 3, Skyhills Subdivision No. 3 May 14, 2001 Page 2 of 3 7. Final grading over the tank shall be such that a positive slope exists away from the septic tank. DRAINFIELD CONSTRUCTION: 1. The drainfield shall be constructed to the dimensions shown on the design. The bottom of the trench shall be within 2" of level. Distribution piping must be placed level with perforations down atop a level bed of drainfield rock. Rock should then be placed over the pipe to provide a minimum of 2" of cover. 3. A silt barrier or geotextile fabric must be placed between the drainfield rock and the natural soil backfill. e Monitor tubes must be 4" in diameter and installed at the locations shown on the design. The portion below ground must be perforated. Contractor shall verify the septic tank and drainfield are a minimum 100' away from any pdvate water wells in the area, 150' from a Class 'C" Well or 200' from any community well. Direct bury insulation must be placed over the distribution system if less than 3' of backfill depth is available. Finish grade over the trench must be mounded to prevent settlement or depressions. Grade area surrounding the absorption trenches to drain away. A minimum 2' of accepting soil is required below the drainfield rock for a 5' wide trench. Contractor shall verify this condition prior to placement of the rock. All pockets of unacceptable materials must be removed and replaced. MATERIAL SPECIFICATIONS: 1. Septic tanks must be constructed by a municipally approved septic tank manufacturer. The following pipe materials are approved for use in septic system installations in the Municipality of Anchorage: Cast Iron (perforated and solid), ASTM D3034 or P.V.C. (perforated and solid), ASTM F810 or H.D.P.E. (perforated, but not solid) and ASTM D2662 or A.B.S. (perforated and solid). Insulation shall be at least 2" thick extruded direct burial polystyrene (Dow Chemical Co. Styrofoam HI or equal). Septic tank inlets and outlets shall be fitted with watertight couplings (Caulder, Femco, or equal). 'Lot 30, Block 3, Skyhills Subdivision No. 3 May 14, 2001 Page 3 of 3 5. A permeable geotextile fabdc (Typar, Mirafi or equ.a,I) must be installed between the final drain rock layer and the native so~l layer. 6. All drain rock shall be .5" to 2.5" in diameter with less than 3% passing the #200 sieve. INSPECTIONS: Municipal Ordinance requires a minimum of two inspections. These inspections must be conducted under the supervision of a professional engineer registered in the State of Alaska. The first inspection must be conducted after the excavation of trenches, beds or pits and before the installation of any gravel. A septic tank may be set in place, but may not be backfilled. The second inspection must be conducted after the placement of the geotextile fabric, gravel, distribution piping, standpipes, cleanouts and insulation. No backfill should be in place at the rime'of'inspection. Contractor shall provide a copy of all field survey layout and construction notes for use in preparing the certified as-built of the completed system. Municipality of Anchorage Development Services Department Building Safety Division On-Site Water and Wastewater Program 4700 South Bragaw St. P,O. Box 196650 Anchorage, AK 99519-6650 www.ci.anchorage.ak, us (907) 343-7904 CERTIFICATE OF HEALTH AUTHORITY APPROVAL FOR A SINGLE FAMILY DWELLING Parcel I.D. 011.122.62 i. Expiration Date: ~ o .~, O - O ?, GENERAL INFORMATION Complete lega! description Lot 30, Block 3, Skyhills Subdivision No. 3 Location (site address or directions) Sky Mountain Circle Current Property owner(s) The Petersen Group, Inc. Day phone 562.1170 Mailing address 3820 Lake Otis Parkway, Suite 204 Anchoraqe, AK 9 Lending agency Day phone Mailing address Real Estate Agent Day phone Mailing Address Unless otherwise requested. HAA will be held by DSD for pickup. 2. NUMBER OF BEDROOMS: Four (4) 3. TYPE OF WATER SUPPLY: Individual Well Individual Water Storage Community Class ~ Public Water System Well TYPE OF WASTEWATER DISPOSAL: [] Individual On-site [] [] Individual Holding tank [] [] Community On-site [] [] Public Sewer [] The Municipality of Anchorage Development Services Department (DSD) Issues Certificates of Health Authority Approval (HAA) based only upon the representations given in paragraph 5 by an independent professional civil engineer registered in the State of Alaska, Certificates of Health Authority Approval are required for the transfer of title (except between spouses) for properties served by a single family on-site wastewater disposal and/or water supply system. DSD also issues HAAs upon request to homeowners. Certificates of Health Authority Approval are valid for 90 days frcm the date of issue for properties served by a private or Class C well and may be reissued with new water sample results less than 30 days old. (Certificates may be reissued for a period of up to one year with valid water samples.) Certificates are valid for one year for properties served by Class A or B wells or a public water system. The Municipality of Anchorage is not responsible for errors or omissions in the professional engineer's work. 4. STATEMENT OF INSPECTION BY ENGINEER As certified by my seat affixed hereto and as of the vaIidation date shown below, I redly that my investigation, based on procedures outlined in the Health Authority Approval Guidelines for this application, shows that the on- site water supply and/or wastewater disposal system is(are) safe, functional and adequate for the number of bedrooms and type of structure indicated herein. I further vedfy that based on the information obtained from the Municipalit7 of Anchorage files and from my investigation and inspection, the on-sita water supply and/or wastewater disposal system is(are) in compliance with all applicable Municipal and State codes, ordinances, and regulations in effect at the time of installation. Name of Firm Anderson En.qineerinq Address P.O. Box 240773 Anchoraqe, AK 99524 Engineer's Printed Name Michael E. Anderson, P.E. 5. DSD SIGNATURE ~ Approved for L.~ Disapproved. Conditional approval for bedrooms. Phone 522.7773 Date 2/5/02 '. ~.~,. OF,..AI ~ ~7: , ~. ,-.'~ ' ~;;&~.~ ..... .t....~ .....,. ~'. CE-~81 . :-~' bedrooms, with the following stipulations: Additional Comments Attachments: HAA Checklist Septic System Advisory Well Flow Advisory X Maintenance Agreements Supplemental Engineer's Report Other Original Certificate Date: Bo Legal Description: WELL DATA Well type Date completed Total depth Municipality of Anchorage Development Services Department Building Safety Division On-Site Water & Wastewater Program 4700 South Bragaw St. P.O. Box 196650 Anchorage, AK 99519-6650 www.ci.anchorage.ak.us (9O7) 343-7904 HEALTH AUTHORITY APPROVAL CHECKLIST Lot 30, Block 3, Sb/hill; Subdivision No. 3 If A, B, or C provide PWSID # Sanitary seal (Y/N) Cased to ft. FROM WELL LOG ParcellD: 011.122.62 Date of test Static water level Well production WATER SAMPLE RESULTS: Coliform colonies/100 mi. Date of sample: -.. SEPTIC/HOLDING TANK DATA Tank Type/Material Septi~;teel Tank size 1,2~ gal. Foundation cleanout (Y/N) Y Date of pumping ABSORPTION FIELD DATA Date installed 6/26/2~1 Length 41 Total depth 12 ft. Date of adequacy test g.p.m. We, Log (Y/Ni Wires properly protected (Y/N) Casing height (above ground) AT INSPECTION in, Nitrate mg/I. Collected by: gp.m. Number of Compartments 2 Depression over tank (Y/N) _N. Pumper N/A Other bacteria colonies/100 mi. Fluid depth in absorption field before test __ in. Elapsed Time: __ min. Final fluid depth __ Any rejuvenation treatment (past 12 mo.) (Y/N & type) Date installed 6/26/200t Cleanouts (Y/N) Y High water alarm (Y/N) N Soil rating (g.p.d./ft2 or ft2/bdrm) 1.2 GPD/SF System type Deep Trench ft. Width 3 ft. Gravel below pipe. 7 Eft. absorption area 574 ft2 Monitoring tube Y Depression over field N Results (Pass/Fail) Water added gal. ~n. Absorption rate >= N If yes, give date For bedrooms New depth in. gp.d. D. LIFT STATION Date installed 'Pump on" level at __ in. Datum E. SEPARATION DISTANCES Size in gallons 'Puml~ o~ level at Cycles tested SEPARATION DISTANCES FROM WELL ON LOT TO: Septic tanldlift station on lot NIA Absorption field on lot N/A Public sewer main N/A Sewer/septic service line N/A Manhole/Access (Y/N) High water alarm level at Meets alarm & circuit requirements? in. On adjacent lots N/A On adjacent lots Public sewer manhole/cleanout N/A Holding tank N/A SEPARATION DISTANCES FROM SEPTIC/HOLDING TANK ON LOT TO: Building foundation >5' Water main >10' Property line >5' Water service line >10' Absorption field >5' Surface water >t00. Wells on adjacent lots >100. SEPARATION DISTANCE FROM ABSORPTION FIELD ON LOT TO: .. Property line >10' Water Service line >10' Building foundation >10' Surface water >100' Water main >1~ Ddveway, parking/vehicle sto~age >25' Cuffain drain Npn~ Noted Wells on adjacent lots >100. F. COMMENTS Lot is served by AWWU wp~ system. G. ENGINEER'S CERTIFICATION I certF~y that I have determined through field inspections and review of Municipal records that the above systems are in conformance with MOA HAA guidelines in effect on this date. Engineer's Printed Name Michael I~. Andemon, P.E. Date 2/~2~2 Data of Payment Receipt Number / ~ 7 b ~' ~ ~, (Rev. 12/00) Date of Payment Receipt Number