Loading...
HomeMy WebLinkAboutSAMPSON ESTATES BLK 3 LT 7Sampson Estates Block 3 Lot 7 #051-811-33 $USMITTA1 AUG: 5 2014 Municipality of Anchorage Community Development Department Page On -Site Water and Wastewater Program 4700 Elmore St. • P.O. Box 196650 Anchorage, AK 99519-6650 • http://www.muni.org/onsite • (907) 343-7904 ON-SITE WASTEWATER INSPECTION REPORT Permit Number: OSP121089 PID Number: 051-811-33 ❑ New El 1 of 3 Upgrade Name: Mollie Hall ABSORPTION FIELD Address P.O. Box 770246 Eagle River, AK 99577 ❑✓ Deep Trench ❑ Shallow Trench ❑ Bed 9 Mound ❑ Other Phone 688-3667 Number of Bedrooms 4 Soil Rating •8 GPD/SF Total depth from original grade 12R. LEGAL DESCRIPTION Depth to pipe invert from original grade Gravel depth beneath pipe Subdivision Block Lot 4 Ft. 8Ft. Sampson Estates 3 7 Fill added above original grade Gravel length Township Range Section 1-2 Ft. 50 Ft. Gravel width Beds: Number of Lines Distance between lines SEPARATION DISTANCES 3Ft. Ft. To From Septic Tank Absorption Field Lift Station Holding Tank Sewer Line Total absorption area 800 Ft2 Number of trenches One Dist. between trenches Ft. Well >100' >100' N/A N/A >25' TANK ❑p Septic 0 S.T.E.P. 0 Holding ■ Other Manufacturer Capacity Surface Water >100' >100' N/A N/A Anchorage Tank 1,250GaI. Material Number of compartments Lot Line >5' 1'**' N/A N/A NA Steel Two Foundation >5' >10' N/A N/A LIFT STATION Manufacturer Capacity Curtain Drain None Noted Gal. Remarks **See Lot Lilne Waiver. Pump on level at Pump off level at High water alarm at in. in. in. Pump make and model Electrical inspections performed by Installer PIPE MATERIAL House to tank D3034 TankD3034 drainfield PCN Construction Drainfeld HDPE CO/MT D3034 Inspector MEA BENCH MARK (Assumed elevation) 100.0ft InspectionLocation dates: 91 5/29/12 z•. 5/29/12 and description 3rd 5/30/12 4'" Bottom of Siding COMMUNITY DEVELOPMENT DEPARTMENT APPROVAL Conditional Approval: Date �`_� �lk,it . SF't.• �••�t� as �i, �,/ so 1k 4918 d\ ' *vi i.. J......• •... t: 1110441••••••• • • en • 11 w tae • (/1/ Date / a,--/ 7-l4 MICHAS, E. ANDLIRSON :Lk el i f.� CE -4381 •' $``• I, <0.•.8'1 ,1Y ••••ky r i enApproved ,,��\\\�i100"." Ar/ / , LOT 7, BLOCK 3, SAMPSON ESTATES SUBDIVISION DESIGN FACTORS: Four Bedroom House Perc. Rate: 6-15 Min./Inch Application Rate: .8 GPD/SF SYSTEM REQUIREMENTS: Deep Trench System 1,250 Gallon Septic Tank 8' Drainfield Rock 4 Bedrooms X 150 GPD/.8 GPD/SF (Application Rate) = 750 SF Absorption Area 750 SF/16 SF/ LF = 46.9 LF Trench Length THEREFORE: Construct a 50' Long x 3' Wide x 8' Effective Depth Absorption Trench at the Location Shown. Distribution Line to be Placed at 4' Below the Existing Surface. Total Depth to be 12' Below the Surface. Decommission Existing Septic System in Accordance with Municipal Code. Provide 4' of Cover Over Septic Tank. 3'6" 6" 8'0" Natural Backfill 5' Geotextile Fabric 4" Perforated PVC (Holes Down) Drainfield Rock TYPICAL DEEP TRENCH SECTION (NO SCALE) -.�P'C�.. .. ;qCq.. NOTE: Grade Area Over Trench to Drain Away. Minimum 6' Separation From Bedrock. Minimum 4' Separation From Groundwater. Minimum 100' Separation From Wells in the Area. Minimum 100' Separation From Surface Water or Streams. / 49th O t MICHAEL E ANDERSON • E': • J, No. CE.43e1 / ♦f %.Ph....s&'t,9 Municipality of Anchorage DEVEOPMENT SERVICES DEPARTMENT 4700 South Bragaw Street Anchorage, AK. 99519-6655 - 343-7904 On -Site Wastewater Disposal System or Well Inspection Report Permit Number: OSP121089 PID No. 051-811-33 Page 3 of 3 U 2 27) In 99.2 CH CO 00 Existin. / sFinished ,250 Gallon Septic Tank 95.2 Existing & Finished Grade 99.8 95.05 U Geotextile Fabric 94.1 Drainfield Rock 86.1 �/— 80.1 50' (Trench Length) PR❑PILE AS-3UILT No Scale 94.1 i 4 1 49th •• • MICHAEL E. ANDERSON j 1 •I�`�f'. Na. CE -4381 j ~� ANDERSON ENGINEERING P.O. BOX 240773 ANCHORAGE, AK 99524 522-7773 677-7766 (FAX) August 5, 2014 Municipality of Anchorage Development Services Department On -Site Water and Wastewater Program P.O. Box 196650 Anchorage, AK 99519-6650 Subject: Lot 7, Block 3, Sampson Estates Subdivision Separation Distance Waiver Absorption Trench to Lot Line Dear On Site Services Engineer: SUBMITTAL AUG 5 2014 65-1-i li-53 A second absorption system was placed on Lot 7, Block 3, Sampson Estates Subdivision in May of 2012. The lot line was not located prior to placement of the new absorption trench and it was laid out relative to the existing failed trench on the property. The trench is located within 1' of the south property line. The septic system on the lot to the south is more than 50' from the common property line and is not impacted by the location of this absorption trench. We therefore request a waiver be issued allowing the trench to be 1' from the south property line. Sincerely, Michael E. Anderson, P.E. 051914003 g 15-114 26- 67/3S62 Municipality of Anchorage P.O. Box 196650 • 4700 Elmore Road Anchorage Alaska 99519-6650 • (907) 343-7904 • Fax (907) 343-7997 http://www.munLorgiOnsite Development Services Division On -Site Water and Wastewater Program **** VARIANCE/WAIVER REVIEW **** Waiver#: 141303 COSA#: PID#: 051-811-33 Legal Description: Sampson Est. B-3 L-7 Engineer: Anderson Engineering .Applicant: Mallie Hall Permit#: 121089 Your request for a waiver of the required 10 feet horizontal separation from the absorption field to the property line has been approved. The approved separation distance is 1.0 feet. This waiver approval applies to the existing absorption field only. Any future upgrade to the on- site wastewater disposal system will require all separation distances be met or another approval from this department. ® The affected adjacent property owner(s) have been given a 7 day notice regarding this waiver. n Notarized letter(s) of non -objection have been received from the owner(s) of the affected adjacent property. ❑ Adjacent properties are not affected by this waiver. Waiver is Granted: X Waiver is not Granted: Date: / Approved by: f 7 viewer /1L On -Site Wastewater Disposal System Permit MUNICIPALITY OF ANCHORAGE Development Services Department On -Site Water & Wastewater Program 4700 Elmore Road, PO Box 196650 Anchorage, AK 99519-6650 Telephone: (907) 343-7904 Permit Number: OSP121089 Tax Code Number: 05181133000 Work Type: Septic Upgrade Permit Effective Dates: May 24, 2012 to May 24, 2013 Design Engineer: ANDERSON ENGINEERING Subdivision: SAMPSON ESTATES Site Legal Address: SAMPSON ESTATES BLK 3 LT 7 G:1560 Owner/Address: " �aq4a a . 31 )30t4 HALL MALLIE CLINTON & JOELLE SLOAN REVOCABLE TRUSTS HALL M C & PO BOX 770246 EAGLE RIVER AK 995770246 Site Mailing Address: 22615 SAMPSON DR, Chugiak Lot Size in Sq Ft: 40152 Total Bedrooms: 4 This permit is for the construction of: Y Disposal Field Y Septic Tank N Holding Tank N Privy N Private Well N Water Storage All construction must be in accordance with: 1. The attached approved design. 2. All requirements specified in Anchorage Municipal code Chapters 15.55 and 15.65 and the State of Alaska Wastewater Disposal Regulations (18AAC72) and Drinking Water Regulations (18AAC80). 3. The wastewater code requires inspections during the installation. The engineer must notify the Development Services Department at least 2 hours prior to each inspection. Provide notification by calling (907) 343-7904 (24 hours). 4. From October 15 to April 15, a subsurface soil absorption system under construction during freezing weather must either: A. Open and Close on the same day. B. Covered, sealed, and heated to prevent freezing. Special Provisions: PRIOR TO CONSTRUCTION: A testhole shall be completed to verify the design prior to construction. The results shall be sealed by the engineer and submitted to the On-site inspector for approval during the bottom -of -hole inspection. The contractor may proceed with construction prior to the completion of seven day groundwater monitoring results at his own risk. Received By: 7I�`� Date: s �9rl v Issued By:itiowv,Y/' jIi: Date: MUNICIPALITY OF ANCHORAGE Community Development Department Development Services Division On -Site Water & Wastewater Program Mayor Dan Sullivan ON-SITE SEWER/WELL PERMIT APPLICATION FOR A SINGLE FAMILY DWELLING Phone: 907-343-7904 Fax: 907-343-7997 Parcel I.D. 051-811-33 Property owner(s): MaIlie Hall Day phone: 688-3667 Mailing address : P.O. Box 770246 Eagle River, AK 99577 Site address: 22615 Sampson Drive Chugiak, AK 99567 Legal description (Sub'd., Block & Lot): Sampson Estates, Lot 7, Block 3 Legal description (Township, Range & Section) Lot Size' 40,152 Sq. Ft. Number of Bedrooms: Four (4) THIS APPLICATION IS FOR: (® all that apply) Absorption Field X Septic Tank X Holding Tank ❑ Privy ❑ Private Well ❑Water Storage ❑ THIS APPLICATION IS AN: Initial ❑ Upgrade X Renewal ❑ THIS APPLICATION INCLUDES A VARIANCE / WAIVER REQUEST FOR: I certify that the above information is correct. I further certify that this application is being made for a Single Family Dwelling and is in accordance with applicable Municipal Codes. 7014-(„LE (Signature of property owner or authorized agent) Permit/Rush Fees: 1530— Waiver Fees: Date of Payment: £Z2a/i2 Date of Payment: Receipt Number: Oa 12L t Receipt Number: Permit No. OSPI a. I O?7 Waiver No. C:\Users AndEng\Desktop\Mike1Sampson Estates\Permft Application Lot 7.docC:\UserslAndEng\Desktop\Mike \Sampson Estates'Permit Application Lot 7.doc ANDERSON ENGINEERING P.O BOX 240773 ANCHORAGE, AK 99524 522-7773 677-7766 (FAX) May 21, 2012 Municipality of Anchorage Development Services Department On -Site Water and Wastewater Program 4700 South Bragaw Street Anchorage, AK 99519-6650 Subject: Lot 7, Block 3, Sampson Estates Subdivision Septic System Design and Permit Application Impacts to Adjacent Properties Dear Onsite Services Engineer: The existing septic tank and absorption trench on Lot 7, Block 3, Sampson Estates Subdivision are in a state of failure and must be replaced immediately to prevent damage to the house and possible environmental problems. We are therefore requesting a permit be issued for the upgrade of the septic system to accommodate the four-bedroom home on the lot. The attached Site Plan and backup documentation identify the location and configuration of the upgrade to the proposed septic system. The existing septic tank and absorption trench will be decommissioned in accordance with Municipal Code. A new 1,250 gallon septic tank will be placed near the same location as the existing tank. Also identified on the plans are the locations of the existing well. No conflicts exist between the existing septic system and the systems on adjacent lots. The wells on this and adjacent lots are more than 100' from the proposed improvements. Drainage arrows are shown indicating the current drainage patterns. The drainage patterns will be maintained after construction. The test hole placed on the lot indicated silty gravel with some sand (GP). The application rate was determined to be 180 square feet per bedroom. We are proposing to construct a 50' long by 3' wide absorption trenches with 8' of gravel beneath the distribution pipe. The distribution pipe in the trench will be placed at 4' below the surface with the total depth at 12'. A test hole will be placed prior to construction to verify the percolation rate, water table and bedrock locations. If conditions are found to be different than anticipated work will stop and a new design completed and submitted for approval. It is imperative the septic system be reconstructed soon as the existing system is currently backflowing into the house. Lot 16, Block 3, Sampson Estates Subdivision August 22, 2007 Page Two The ground surface on the lot slopes slightly to the southwest at very shallow grades approaching 1%. The trench will be constructed parallel to the contours of the ground as much as possible and in conformance with design criteria. A minimum of 100' will be maintained between all components of the septic system and the existing wells and surface water in the area If the system is constructed in accordance with our design the following statements apply: 1. The system, if constructed as designed, will have no adverse impact on the wells in the area or those to be constructed in the future. 2. The system, if constructed as designed, will have no adverse impact on existing septic systems in the area or those to be constructed in the future. 3. The system, if constructed as designed, will have no adverse impact on reserve space, either surface or subsurface, on any lots located in the area. 4. The system, if constructed as designed, will have no adverse impact on drainage patterns in the area. The current drainage pattern will be maintained. Sincerely, Michael E. Anderson, P.E. Attachments • • \ • / \ • • �\ CHNS3NIONS NOSY3QNV / 3 / w s C a 0 0 C cV 0 v 0 "a`x� \ \ 0 ` Y� PV yL C v - V p L Ti 90 he 302 \\ -tea ">if c 52 T3 \ Wa°aa' xcc \ i— c a._ a'.� o c,p c • i� O W OQQ3 v n O 1 00. � ��a I 0- I ' 4.1 o c ▪ 0 ui 0 / / / �\ 4: y i \ i c °o mzii) _ W` c'c J• `\ .i ' a` ' 'n VN \ 0 in °1a .>).N\ \ V N 3 N CC UO _0\ rE v 4 'S..- • • • • • • \ \ \ \ \ •\ ••• 0 Z 0 J 0 c O c 0 r ▪ o U ~ = 00.Eti W vC Cj O4 y �0 rU I 0 " 0 1 -1 -/ti OUN z Q J 0_ W 11 0 SCAL LOT 9, BLOCK 3 O M N Y / 0 0 2 OJ CO / / 05 / / O / 1 I "%%% {. , 144.. le u b a•N0 O _- C w u -wi LOT 7, BLOCK 3, SAMPSON ESTATES SUBDIVISION DESIGN FACTORS: Four Bedroom House Perc. Rate: 6-15 Min./Inch Application Rate: .8 GPD/SF SYSTEM REQUIREMENTS: Deep Trench System 1,250 Gallon Septic Tank 8' Drainfield Rock 4 Bedrooms X 150 GPD/.8 GPD/SF (Application Rate) = 750 SF Absorption Area 750 SF/16 SF/ LF = 46.9 LF Trench Length THEREFORE: Construct a 50' Long x 3' Wide x 8' Effective Depth Absorption Trench at the Location Shown. Distribution Line to be Placed at 4' Below the Existing Surface. Total Depth to be 12' Below the Surface. Decommission Existing Septic System in Accordance with Municipal Code. Provide 4' of Cover Over Septic Tank. 3'6" 6" - 8'0" Natural Backfill 5' Geotextile Fabric 4" Perforated PVC (Holes Down) Drainfield Rock TYPICAL DEEP TRENCH SECTION - NOTE: (NO SCALE) Grade Area Over Trench to Drain Away. Minimum 6' Separation From Bedrock. Minimum 4' Separation From Groundwater. Minimum 100' Separation From Wells in the Minimum 100' Separation From Surface Wa u: *♦♦ % 49th � l�`�: • vtdS Area. ♦m} MICHAELEANOERSCN ter or Streams. ♦♦% No. CE -4381 I MUNICIPALITY OF ANCHORAGE DEVELOPMENT SERVICES DEPARTMENT 4700 BRAGAW STREET ANCHORAGE, AK 99519-6650 DEPTH (feet) 1 2 3 4 5 6 7 8 SOILS LOG - PERCOLATION TEST LEGAL DESCRIPTION: PERFORMED FOR: MALLIE HALL DATE: 5/24/2012 PROJECT No • PARCEL ID#: TECHNICIAN: M. ANDERSON Lor 7, BLOCK 3, SAMPSON ESTATES SUBDIVISION 9 10 11 12 13 14 15 16- 17 18 19 20 a OB/OG TEST HOLE # 1 SILTY GRAVEL a. GM GREEN/GRAY 4 WAS GROUND WATER ENCOUNTERED' IF YES @ W DEPTH OF WATER AFTER MO BOTTOM OF HOLE DATE OF MO SLOPE NV1d 3115 33S 4i ��P�E,OF q(q,� -♦i 0 49jth • ?,3A ;MICHAEL E. ANDERSON 1. C.: Professional Engineers Stamp: SITE PLAN SEE SITE PLAN T DEPTH? IITORING: 4ITORING' P SEE SITE PLAN E DATE READINGNET GROSS TIME (MINUTES) NET TIME (MINUTES) WATERDEPTE To (INCHES) DROP (INCHES) 5/29/12 TEST HOLE PRESOAKED PRIOR TO TESTING: 1 2 3 4 3 4 PERCOLATION RATE: 14 (MIN/INCH) PERC. HOLE DIA. 6 (INCHES) TEST RUN BETWEEN: 4.0 FT. and 5.0 FT. COMMENTS' TEST HOLE PRE SOAKED PRIOR TO TEST. TEST PERFORMED BY ANDERSON ENGINEERING TECHNICIANS. I, MICHAEL E. ANDERSON CERTIFY THAT THIS TEST WAS PERFORMED IN ACCORDANCE WITH ALL STATE AND MUNICIPLE GUIDELINES IN EFFECT ON THIS DATE: 5/29/2007 MUNICIPALITY OF ANCHORAGE • \ P t 1 DEPARTMENT OF HEALTH & ENVIRONMENTAL PROTECTION ENVIRONMENTAL ENGINEERING DIVISION 825 L Street - Anchorage, Alaska 99501 Telephone 264-4720 ON-SITE SEWAGE DISPOSAL SYSTEM AND/OR WELL INSPECTION REPORT NAME r 5'4 S 4M a- �'''+ c'f.v�../.,z65vs-ivs- PHONE T NEW ❑ UPGRADE MAILING ADDRESS .ou w Wiz/ 4'.,5--.5-a fle.-:cI,.. .4kIs-o3 LEGAL DESCRIPTION Lf 7 6 /h 3 S, .,..,..,,sem, E,r7'-4 C.r -T is.v ,*Z. / Gil fiec �� LOCATION /re ie.,71 C r e e i NO. OF BEDROOMS SEPTIC TANK DISTANCE TO: Well,� /ftej Absorption area a 9 Dwelling / PERMIT NO. p 1� ,.7 3 J 7 Manufacturer �C 7�A % t Material S, � , / No. of compartment i Liq. capacity in gallons /001./001.:, IF HOMEMADE: Inside length Width Liquid depth G �' J02 O z < 1 F - DISTANCE TO: Well Dwelling PERMIT NO. Manufacturer Material Liquid capacity in gallons TILE DRAINFIELD TRENCH DISTANCE TO: Well leo .T Foun� ti q Nearest lot line 58, j PERMIT NO. 8.y CG, 73 No. of lines Length of each line i pisS Total llee'ngth of lines � Trench width . j® inches Distance between linesl� Top of tile to finish grade 11 / ( Material beneath tile -7 A inches Total effective absorptiotn/area C 4/6 `W SEEPAGE PIT Length Width Depth PERMIT NO. Type of crib Crib diameter Crib depth Total effective absorption area DISTANCE TO: Well Building foundation Nearest lot line J J w Class Depth Driller Distance to lot line PERMIT NO. DISTANCE TO: Building foundation Sewer line Septic tank Absorption areals) OTHER PIPE MATERIALS ,GI -,---areUt y4' U .C' \` We II SOIL TEST RATING IS�� f INSTALLER i® J /,7 4 / JV[ 4 A.oin f $ �<rc ei IFC 7`i 015' 11 o. .'"Se %p REMARKS t n •iAN k- 4®d®i\®� 1 ���OF.w'�g�l �`/.� �. -• •ir i "� ,• A ,k: . , r v - k 1,-,T- • t,.' 2225-E �' P y. ;Q• 65 a ra• JURE 25. 1_7L , 'k %�I��ONAL �c _ APPROVED DATE LEGAL Lt 7 /gilt' 3 S4 kez/elSot ,s- 72-013 (Rev. 3/78) LOCATION OF WELL (Please complete e cher la, Ib or Ic.) la. Borough An ch Subdivision Sampson Lot Block 3 Ic. WATER WELL RECORD STATE OF ALASKA DEPARTMENT OF NATURAL RESOURES Division of Geological a Geophysical Surveys Drilling Permit No. A. D. L. No. I D.I 1/4gtre. _. of.- of__ -of — Suction No Township ND sD Range EDI Meridian w❑ DISTANCE AND DIRECTION FROM ROAD INTERSECTIONS Street Address and Area of Well Location 3. OWNER OF WELL:Mr. Ray Pelletier BeOoistruction Anchorage, Ak. 9950 Address: 2. WELL LOG Feet Below Surface Motorial Type Top Bottom 4. WELLr DEPTH: (final) cF IJ ft. 5..9ATE OF CO1 LETI0N84 Soil, gravel 0 Pavel, SilL, Sand 3 Gravel, salt, warmer 58 3 38 45 Gravel, silt, sand 45 55 Gravel, gray sand 55 110 Gravel, sand, silt, water 110 Gravel, sand, water 132 132 144 6. 0 Cable tool )(Dietary 0 Drlvon O Dug 0 Auger D Jetted ❑ Bored ❑ Other: 7. USKTA Domestic D Public Supply D', ndustryi D Irrigation D Recharge D Gommerleal 0 Test Wotl D ()fluor: 6f C(y,SING:: Thr!Q()de fih Welds p I! Alpm. " .in tq1 4Pi� i� Depth I j!elght 1 7 I diem. In 6,1 I t Depth I Stickup I 9. FINISH OF WELL: Typo: ! , �ci ! Slot/Meth ISlze: Set between` Backfilling Dlamoteri Longo : 'ft. and �,[ 1. if 1. Gravel pack Mur\flcrPAury Di' DEPT. ANCHORAGE =NVIRniJ,Rj�' HE, r �RAcir �TAL PRC F C)7pnt NOV I 1O. STATIC WATER LEVEL 'rv'" CI ! '4t. 0 Above or KBe ow land surface Equipment used:. I, I i ip if -51 Date 1984 RECEIVED II. PUMPING LEVEL below iapd surface ond,YIELQ' f1. attar hrs. pumping � ft. ':after : hrs. pumping g.p.m. g.p.m. 12.GROUTING Well Grouted Yes! D No Material: 0 Neat CementO Other: 13. PUMP: (if available) HP Longth of Drop Pipe ft. capacity g.p.m. D Subm. E) Jet Centrificat O', Other 16. WATER WELL CONTRACTORS CERTIFICATION: 14.REMARKS:production of 15 GPM 15. Water Temperature _° This well was drilled under my jurisdiction and this report is true to the best of my knowledge and belief; Magnuson Drilling AA 5385 Address Signed Registered Business Nome P.O. Box 770504 Eagle River Contract License Number Ak. 99577 [Form 02-WWR (11/81) Authorized Represent° ve Aug. 21, 1984 Copy Distribution: WHITE- Stole DGGS, PINK -Driller, CANARY- Customer 'oN 10001 S9Sf1 0k PERMIT NO: DATE ISSUED: ���I C: I F" gr-; a_ -r 1011--111E3�PkI9 IF= DEPARTMENT OF HEALTH AND ENVIRONMENTAL PROTECTION 825 L STREET, ANCHORAGE, AK 99501 264-4720 �FE: I 'TIE P40 EE: FR: IEE tF:"EZ.�IMI I "IF 840673 , 08/07/84 APPLICANT: SHASTA CONST. ADDRESS: 280 W. 34TH. SUITE 500 ANCHORAGE, AK 99503 CONTACT PHONE: 694-5195 LEGAL DESCRIP: SUBDIV18I81ft SAMPSON ESTATES SECTION: 3 TOWNSHIP: 15N LOT SIZE: 40152 (SQ.FT. OR ACRES) MAX BEDROOMS: 3 LOT: 7 RANGE: 1W BLOCK: 3 •Listedbelow are the options available� to you in designing your septic system. Choose the option that best fits your site, ~ 1-FREIP4CALA DEPTH TO PIPE BOTTOM (FT.) 4.0 GRAVEL DEPTH (FT.) 6.0 TOTAL DEPTH (FT.) 10^0 GRAVEL WIDTH (FT.) 2.5 GRAVEL LENGTH (FT.) 38.0 GRAVE~ VOLUME (CU.YDS.) 22.8 TANK SIZE (GALS) 1,000.0 ** SOIL RATING (SQ.FT./BR) ^ 150 ** TANK MUST HAVE AT LEAST TWO COMPARTMENTS E3EEI3 4.0 0.5 4.5 9"O 36.0 25.3 1,000.0 ** 150 WAP ��F17. Nil 4.0 3.5 7.5 5.0 49.0 36.2 1,000.0 ** 150 I certify that: 1° I am familiar with the requirements for on-site sewers and wells as set forth by the Municipality of Anchorage (MOA) and the State of Alaska. 2. I will`install the system in accordance_ with all MOA- codes and regulations, and in compliance with the design criteria of this permit. 3"_ I will -adhere to all MOA and State of Alaska requirements for the set. back distances from any existing well, wastewater disposal system or public sewerage system- on this or any adjacent or nearbylqt. 4. I understand that this permit is valid for a maximum of 3 bedrooms and any enlargement will require an additional permit. IF A LIFT STATION IS INSTALLED IN AN AREA COVERED BY MOA BUILDING CODES, THEN (1) AN ELECTRICAL PERMIT AND INSPECTION MUST BE OBTAINED; (2Y AG-BUILTS WILL NOT BE APPROVED WITHOUT AN ELECTRICAL INSPECTION REPORT; AND (3) THE ELECTRICAL WORK MUST BE DONE BY A LICENSED ELECTRICIAN. SIGNED APPLICANT: ^S CONST. ISSUED BY DATE: DATE: ,7/7/2 / PERFORMED FOR: LEGAL DESCRIPTION: MUNICIPALITY OF ANCHORAGE DEPARTMENT OF HEALTH AND ENVIRONMENTAL PROTECTION 825 L. Street, Anchorage, Alaska 99501 264-4720 SOILS LOG — PERCOLATION TEST s/7erL5 61,stn.i-C f /vr� 111 SOILS LOG PERCOLATION TEST DATE PERFORMED: Sej 3,1/4 Z- t- 7 43 /1r - ,Set pnsE �. E 211C -S-1 /.5' / DEPTH // / / t", SLOPE SITE PLAN (FEET) 0R 6-A ' 1G / 10- 11 - 12- 13- 14 e J D A s;/ t), s J7 6-ra vt / g -o st kr !ul F 15 - .®.. . .4./. (.i . Sir n 17 ;r ° 49TH 18.1,'r•P . 2225-E p' < .4• JJNE 25, 1971 20- 11‘@h® 1 ® COMMENTS t; (7‘,6 i12rGL WAS GROUND WATER ENCOUNTERED? IF YES, AT WHAT DEPTH? S L O P E Le— Reading Date Gross Time Net Time Depth to Water Net Drop / /y Fr Jr /t-, s;ss 2 t/ ,// I/ L/ // 3 1, (.:2. s /s;b `/ /6 ' 645_ ' / 6 PERCOLATION RATE �0 �3ec��u� Eminates/inch) TEST RUN BETWEEN FT AND FT A lc f O •Ro /0 `u///7 rs PERFORMED BY: 6Lt '/Y 72-008 (6/79) CERTIFIED BY: DATE:/�/�L� 1Vlumcipal>Ity of Anchorage Department of Health and Hutnan'Setvlces,t ` Division of Environmental Services On-SiteServices •Sechon `825 i Street , Room502 . •P.O Box.196650 Anchorag•e AK:_99519-6650' www ci.ancho�age.ak us r • (907) 34324744 CERTIFICATE OF HEALTH AUTHORITY APPROVAL• FOR A''SINGLE FAMILY: DWELLING, • Parcel I.D 051-811-33 :1: 51.811 33 r': GENERAL INFORMATION'-; r HAA # Expiration Dale Complete legal:description • •Lot 7, Block 3,•SampsonEstates Subdivision ` - •, Location'(site address or directions) 22615 Sampson Drive , , ; `:i Current Property uwner(s)',Dennis and Gwenn Colon- 'Dayphone •240.6577 Mailing address • 22615 Sampson Drive :t Chugiak, A}( 99567.9 404 <r. ylir Lending agency Day phone .. Mailingaddress • RS Estate 'Agent:' Jennifer Renard Day phone _ :240.6577 ` • Mailing'Addrese;' s r t Unless otherwise requested HAA will be held by DHHS for pickup. HAA picked up bya NUMBER OF BEDROOMS: ;Three (3). ' • 3.' :TYPE OF WATER SUPPLY: Individual Well Individual Water Storage Community Class • Well PubTic Water System TYPE OF WASTEWATER DISPOSAL 'v• Individual On site = ❑: ' Individual Holding tank ' ❑ ' Community On-site c' ❑ .} Public Sewer The Municipality of Anchorage Department of Health and Human Services (DHHS) Issues Certificates of Health Authority Approval (HAA) based only upon the representations given in paragraph 5 by an independent professional civil engineer registered in the State of Alaska. Certificates Health Authority Approval are required for the transfer of title (except betweenspouses) on properties served by single family on-site wastewater disposal and/or water supply system. DHHS also issues HAAs upon request to home owners: Certificates of Health: Authority Approval are valid for 90 days from the date of issue for properties served by a private or Class C well arid may be reissued with new water sample results Tess than 30 days old. Certificates are valid for one year for properties served by Class A or B wells or a public water system.' The Municipality,. of Anchorage is not responsible' for errors or: omissions in the professional engineers work: (Rev. iris) 5. STATEMENT OF. INSPECTION BY ENGINEER As certified by my seal affixed hereto and as of the validation date shown below, I verify that my investigation based on procedures outlined in the Health Authority Approval Guidelines for this Health 'Authority Approval t' application shows that the on -Site water supply. and/or wastewater' disposal system is safe, functional and adequate for the number of bedrooms and type of structure indicated herein. 1 further verify that based on the information obtained from the Municipality of Anchorage files and from my investigation' and inspection, the on site water. supply and/or wastewater disposal system is incompliance with' all applicable Municipal and State codes, ordinances, and regulations in effect at the time of installation. , Name of Firm Anderson Engineering -'. Address • P.O. Box 240773 Anchorage, AK 99524' Engineer's Printed Name Michael E. Anderson, P.E. ' • 1 6 DHHS SIGNATURE Approved for _ Disapproved. • Phone 522.7773 r. :Date 1103101.' .EN,,0*R41�r.z .{r bedrooms : , „e i, r ly rF7 irt•eily0:,4:1W . ' Conditional approval for bedrooms with the following stipulations • • Additional Comments By: Attachments: HAA Checklist Maintenance Agreements' Septic System Advisory Supplemental Engineer's Report Well Flow Advisory '.Other Original Certificate Date: / — 14 Expiration Date: Lit- `7 ' Q f Reissue Date: ` . (Rev. 10/99) tinicipality. ofAnchorage Development Services Department Building Safety Division Onsite Water & Wastewater Program 4700 South Bragaw St. P.O. Box 196650 Anchorage, AK 99519-6650 www.d.anchorageak.us (907)3437904 HEALTH AUTHORITY APPROVAL CMEOKLIST Legal Oesraiptlgn. 1.0t 7. Block 3. Sampson Estates 4 WELL DATA Wel type Private = If A. 8, or C provide PWSID # Datecornpreted 101211984 Sanitary seat (YIN) Parcel ID: 051811.33 Weft Log (Y/N)Y Wires properly protected (YIN) Y Total depth 140.1t Cased to 140 ft. Casing height(above•ground) >24 in: FROM WELL LOG AT INSPECTION Date of test 101211984 12/17/2000 Statioavaiaftevet 109 • ft. 115 ft: Well production 15' g.p.m. 6.9 g.p.m. -. WATER BMPI-SfiliBULTS Conformu` Jc O estlOB mi. Nitrate 2.79 mg, Detect samolt (211711000 ' COAected by: MEA 8: SEPiIQFIbtblt1t tANR DATA Tank Typedllt >5eptidSteet Other bacteria 1. cdoniat100 ml. Dateinstalled 8115/1984r Tank slus. J000", gal. Number of Compartments E Cleanouts (YIN) y Foundation a tearidtt'(YJP4t Depression over tank (YIN) B High water alarm (YIN) 14 Dale of pumping. 3I212001 Pumper Sanitary Pumper C. ABSORPTION 'VIIELD.DATA Date atstalteg-1,OItS11984 _ Soft rating (g.p.dJR' or fk>lbdrm)150 SF System type Deep trench Length 45, ft Width 7.5- tt Gravel below pipe 6 ft. Total depth•Qft Eff. absorption area 54011' Monftoringtube Y Depression over field N Qat* of esequatg3est 1211712000 Results (Pass/Fan, Pass For 3 bedrooms Fluid depth bsibSOMtion field before test 15 in. Water added460 gal. New depth31 in. Elapsed Tune: 3,440 min. Final fluid depth 15 in. Absorption rate >= 450 g.p.d. 3ly:rejuvenatIOntreatment (past 12 ma.) ()IN & type) N If yes, give date NIA D. LIFT STATION Date installed Size in gallons Manhole/Access (YM) Pump on' level at in. 'Pump off' level at _ in. High water alarm level at Datum Cycles tested Meets wenn a drools requirements? E. SEPARATION DISTANCES SEPARATION DISTANCES-F;iQM WEIS QNt.OT TO: Septic tankllif station oitlQt>100' On. adjacent:Ott A100' Absorption field on lot >100' • Onadjacenflots >100' Public sewer main WA in. PubRcsetntmanhole/cleanout NIA Sewer /septic service line >29; Hdfdinglatti WA SEPARATION OISTANCES.FRQM SEFROYHOLDING TANK ON"L`OT TO Building foundation >5' Pfopertyaine >5' AbsofptIon field'' »s'. Water main NIA Wat?Cservtcellne WA- Surfacawater >1004 Weals on adjacent lots, >100' SEPARATIQN_DISTANCE FROM,ABSOi3PTION FIELD OR LOTTO Property line >10'aw r Sanding foundation >1'- .Wafirsight Water Service Ode P104; -. Surface -we 0;100' _ OrMtWal;'�atxtn9h!ehr t >2P Gatlin drain _None Noted Wellson•�91agenttots>� 700^ F. COMMENTS G. ENGINEER'S CERTIFICATION; I certify that I have .date►mbedtluougllle/d.8►specUans end. review of Municipal that theabeve systems mein confomiance w1115'MOA.HAAguldefjtletinctfreCLQttfta ala:• Engineer's Printed Name Michael E. Anderson P.E. Data1/5/01 HAA Fee $ Date of Payment 'An ..tyr Receipt Number eCr/ (Rev. 13/00) too " • Waiver Feet$ Qae.ofPayolent Receipt Hunter 12-21-00 17:21 L. CT&E Refit 'Client Name Project Namel# Client Sample ID Matrix Ordered By PWSID t. FROM -CTE ENVIRONIENTAL 5615301 CT&E Environmental Services Inc. 1007765001 Anderson Engineering Lot 7 Blk 3 Sampson Est. Lot 7 Blk 3 Sampson Est. Drinking Water 0 T-642 P.02/03 F-449 Client POO Printed Date/time Collected Date/time Received Date/time 12/21/2000 8:38 12/17/2000 12:10 12/18/2000 14:00 Technical Director /StephenCEC Ede ynJ Released Dy .2 "o"�"^7 Sample Remarks: Panmcter Results PQL Units Method Allowable Prep Analysis Limits ..Date Date Init Waters Department Nitratc-N Microbiology Laboratory Total Coliform 2.79 0.500 mg/L EPA 300.0 0 Received Time Dec.21. 5:24PM 10 max 12/18/00 SCL coi/lOOmL SM189222B 12/18/00 KAP MUNICIPALITY OF ANCHORAGE DEPARTMENT OF HEALTH & HUMAN SERVICES Division of Environmental Services On -Site Services Section P.O. Box 196650 Anchorage, Alaska 99519-6650 343-4744 CERTIFICATE OF HEALTH AUTHORITY APPROVAL FOR A SINGLE FAMILY DWELLING Parcel I D # SSI /l 3 3 &EDD HAA # l' c)11-,n1c1a1 1. GENERAL INFORMATION Complete legal description —32- g 32 Location (site address or directions) Z16/.� 54-ime0S441 Property owner dee ide& rcu o teri}- Day phone Mailing address ZZ6/5 5 ri,1 -) Dei CW -4‘,41-,4`. Lending agency Day phone Mailing address Agent a 2-1 f- /e. Alt,„ Day phone 696— ir-645149 Address Unless otherwise requested, HAA will be held for pickup. 2. NUMBER OF BEDROOMS: 3. TYPE OF WATER SUPPLY: Individual well Community well Public water 3 NOTE: If community well system, provide written confirmation from State ADEC attest- ing to the legality and status of system. 4. TYPE OF WASTEWATER DISPOSAL: Individual on-site Holding tank Community on-site Public sewer NOTE: If community wastewater system, provide written confirmation from State ADEC attesting to the legality and status of system. 72-025 (Rev. 1/91) Front MOA #21 tLcex— e- P./5 5. STATEMENT OF INSPECTION BY ENGINEER As certified by my seal affixed hereto and as of the validation date shown below, I verify that my investigation of this Health Authority Approval application shows that the on-site water supply and/or wastewater disposal system is safe, functional and adequate for the number of bedrooms and type of structure indicated herein. I further verify that based on the information obtained from the Municipality of Anchorage files and from my investigation and inspection, the on-site water supply and/or wastewater disposal system is in compliance with all Municipal and State codes, ordinances, and regulations in effect on the date of this inspection. David R. Dayton P.E. Name of Firm 20210 Donalar St. Chugiak, Alaska 99567 Address Engineer's signature Phone Cife;V7 Date mvaao aeoo�o eoa as (}aviJ R, Ca/Iona 1, '41:s"),..1),, NO. 2205.E es �t?. Ny ts o �" .(4,e s9n.aase0000°� <4e11 6. DHHS SIGNATURE � ?R0 EaatQ''tP, Approved for (?)bedrooms. Disapproved. Conditional approval for bedrooms, with the following stipulations: Additional Comments By. Date 14° ""i CAUTION The Municipality of Anchorage Department of Health and Human Services (DHHS) issues Health Authority Approval Certificates based only upon the representations given in paragraph 5 above by an independent professional engineer registered in the State of Alaska. The DHHS does this as a courtesy to purchasers of homes and their lending institutions in order to satisfy certain federal and state requirements. Employees of DHHS do not conduct inspections or analyze data before a certificate is issued. The Municipality of Anchorage is not responsible for errors or omissions in the professional engineer's work. 72-025 (Rev. 1/91) Back MOA 921 Municipality of Anchorage Department of Health and Human Services HEALTH AUTHORITY APPROVAL CHECKLIST Lmr 7 B4- 3 Legal Description: A. Well Data c Sr Parcel I.D. 65 // 3 3 0o U Well type )?R/0aTz= If A, B, or C, attach ADEC letter. ADEC water system number Log present (Y/N) Y Date completed Vie, Driller YY/A-'Jµssd Total depth /T Cased to /,40 Casing height 3 Sanitary seal (Y/N) i1 Wires properly protected (Y/N) Y FROM WELL LOG AT INSPECTION Date of test 8 Vff V Static water level X09 Well flow /D g.p.m. g.p.m. Pump levell i/%e G/ SEPARATION DISTANCES FROM WELL TO: Septic/holding tank on lot 004` Absorption field on lot Public sewer main /OD y - x.)//4.. ; On adjacent lots /e'c:) f ; On adjacent lots /O° 7 Public sewer manhole/cleanout Sewer service line 7s f Petroleum tank WATER SAMPLE RESULTS: Coliform 0 Nitrate , 9,c) Other bacteria U Date of sample: Collected by: ix) --P B. SEPTIC/HOLDING TANK DATA Date installed /9H Tank size /€20 v Compartments 1- Cleanouts (Y/N) ')' Foundation cleanout (Y/N) Y Depression (Y/N) A/ High water alarm (Y/N) AJ/4- Alarm tested (Y/N) �ig- Date of pumping 7/z 743 Pumper A+�o-rttr,y 1`14.0t4-19Vn 5 SEPARATION DISTANCES FROM SEPTIC/HOLDING TANK TO: Well(s) on lot Obi-- On adjacent lots /Ooh Foundation 5 - To property line ZSR-- Absorption field ZO Water main/service line Z 3- Vz- Surface water/drainage l 0 if;) -.1--- rrll \C- \ g _6\_6\:3..(vojc N d 0ct _l M 72-026 (3/93)* Front CONTINUED ON BACK PAGE C. LIFT STATION Date installed ^'/Y— Manufacturer Size in gallons Manhole/Access (Y/N) Vent (Y/N) "Pump on" level at - - "Pump off Level at High water alarm level Cycles tested Meets MOA electrical codes (Y/N) SEPARATION DISTANCE FROM LIFT STATION TO: Well on lot On adjacent lots Surface water D. ABSORPTION FIELD DATA Date installed (/erfi Soil rating (GPD/Ft2) /-5-741System type avew Length 5‘5Width Zw Gravel thickness 6Total depth /0 Total absorption area s40 Cleanout present (Y/N) y Depression over field (Y/N) Al Date of adequacy test /0///93 93 Results (pass/fail)5 for 3 Bedrooms Water level in absorption field before test 5 % " After test OVIrs � 3 " Peroxide treatment (past 12 months) (Y/N) N If yes, give date SEPARATION DISTANCE FROM ABSORPTION FIELD TO: Well on lot f On adjacent lots loo i To building foundation On adjacent lots f Cutbank Property line 5— To existing or abandoned system on lot A-4 A/4 Water main/service line Surface water /o o f— Driveway, parking/vehicle storage area Curtain drain /Ides E. ENGINEER'S CERTIFICATION I certify that I have checked, verified, or conformed to all MOA and HAA guidelines in effect on the date of this inspection. David R. Dayton P.E. 20210 Donalar St. Signature Chugiak, Alaska 99567 Engineer's Name Date /g', Doyon ; �w s : 2 5 - ° °.��c�;; 0 o„ee HAA Fee $ r..26•5 Date of Payment Receipt Number 72-026 (3193)' Back /0 Waiver Fee $ Date of Payment Receipt Number D. R. DAYTON, P.E., R.L.S. MUMMA= Chugiak, Alaska 99567 20210 Donalar October 4, 1993 WELL FLOW TEST Legal Description: Lot 7, Block 3, Sampson Estates Date of Test: October 1, 1993 Well Depth: 140 ft. Static Water Level: 114 ft. Driller: Magnuson Drilling Requirements: 3 BR - 450 gallons per day (9a7AMINNER 696-2417 Test: The well was tested with the existing pump through an outside hose bib. Volume and drawdown were measured through the test. Results: The well produced 457 gallons in 80 minutes at an average flow tate of 5.7 gallons per minute. Maximum drawdown was 1 ft. The drawdown was fully recovered within 10 min. after pumping was stoppped. The well is currently producing adequately for a 3 BR home. D. R. DAYTON, P.E., R.L.S. MOMENlega Chugiak, Alaska 99567 20210 Donalar October 4, 1993 (907) ENEiff2:. 696-2417 ADEQUACY TEST Legal Description: Lot 7, Block 3, Sampson Estates Date of test: October 1, 1993 Septic Tank: 1,000 gallon, 2 compartment, steel tank (DHHS Records) Absorption System: 45' long x 6'.effective °°depth ..trench (DHHS Records) Soils Rating: 150 sq ft per bedroom (DHHS Records) Requirements: 3 BR - 450 gallons per day Test: Water was pumped into the trench while measuring volume and water level rise at timed intervals. After pumping was stopped, the water level was measured at timed intervals. The results were plotted on a graph of time and gallons absorbed and extrapolated to 24 hrs. Results: The absorption system is currently functioning adequately for a 3 bedroom home. NOTE: There were 58" of water standing in the trench before the test. 24 hrs after the test the water level was back to the.original level. This amount of water standing in the trench may indicate the absorption system is in its waning years. �...7t7 .'�‘ l kith —�C1r� �7 ee(1c nAt U c, 7. I i ,-..o.. ,A, e - : a _.-�AO seg as a.��'a///sani{yYo�f/xj�o�nJwe'i%.;y 6 f,,„ tA• David R. Dayton �' <v P �� J'•"a t40. 2205-E `1; R i • +• +� F /4 .414;i FESSI�� '�.��® COMMERCIAL TESTING & ENGINEERING CO. AleL_ ENVIRONMENTAL LABORATORY SERVICES SINCE 1909 Chemiab Ref .1s Client Sample Matrix Client Name Ordered By Project Name Projectile PWSID REPORT :93.5268--5 1D :L1 B3 SAMPSON EST. :WATER :DAVID DAYTON, P.E. :DVIt) DAYTON :DA of ANALYSIS 5633 B STREET ANCHORAGE, AK 99518 TEL: (907) 562-2343 FAX: (907) 561-5301 WORN Order :71751 Report Completed :10/08/93 Collected ' :10/04/93 @ 14:30 hrs. Received :10/05/93 @ 11:00 hrs. Technical Di.rector:STEPHEN,F. EDE Released. By �j* f'2..- Sample Remarks: ROUTINE SAMPLE COLLECTED BY: D.R. DAYTON./ r QC Allowable Ext., Anal. Parameter Results Qual Units MethodLimits Date Date Tnit Nitrate -N 0.90 mg/L EPA 353.2/300;0 10 10/06 W1 * See Special Instructions Above ** See Sample Remarks Above U Undetected, Reported value is the practical D Secondary dilution, quantification limit. ‘SGS Member of the SGS Group (Societe Generale de Surveillance) UA Unavailable NA Not Analyzed LT = Less Than GT = Greater: Than ENVIRONMENTAL SERVICES IN ALASKA, COLORADO, UTAH, ILLINOIS, OHIO, MARYLAND, WEST VIRGINIA, NEW JERSEY, SOUTH CAROLINA MUNICIPALITY OF ANCHORAGE DIVISION OF ENVIRONMENTAL HEALTH DEPARTMENT OF HEALTH AND ENVIRONMENTAL PROTECTION APPLICATION FOR HEALTH AUTHORITY APPROVAL CERTIFICATE 1. General Information Application Date / (a) Legal Description/�(include lot block, subdivision, section, township, range) L c t- 7 ,&/a c /r 3 .n,P "5a+-. E.s {5 /rs 7-/f /?J /c / 44/ Sec 3 Location (address or directions) P��c'.rr Ch�e-X (b) Applicants Name SAe s Cvr, rty. ,me) Telephone - Home Business Applicants Address 200 3.,51 .53-6 95 3 (c) Applicant Buyer is (check one) Lending Institution ; Other) ' (explain); ; Owner/builder , (d) Lending Institution , /15/ .7 /t e't,,QC RAI/le-Telephone Address G'Ge 2/ c/' - (e) Real Estate Co. & Agent iVeef ,'/-LES' Address£f,1 (,'L ,�/u,�/2 Oz7, Telephone 0614/- X999' (f) Mail the HAA to the following address: 2. Type of Residence Single -Family 15; Multi -Family Number of Bedrooms 3 3. Water Supply 1 1 Other (describe) Individual Well Community Public Note: If community well system, must have written confirmation from the State Department of Environmental Conservation attesting to the legality and status. 4., Sewage Disposal Onsite Public I Community Holding Tank Note: If community well system, must have written confirmation from the State Department of Environmental Conservation attesting to the legality and status. [Page 1 of 2] • 5. Engineering Firm Providing Inspections, Tests, File Search, Data and Information As certified by my seal affixed hereto and as of the validation date shown below, I verify that my investigation of this Health Authority Approval shows that the on-site water supply and/or wastewater disposal system is safe, functional and adequate for the number of bedrooms and type of structure indicated herein. I further verify that, based on the information obtained from the Municipality of Anchorage files and from my investigation and inspection, the on-site water supply and/or wastewater disposal system is in compliance with all Municipal and State codes, ordinances, and regula- tions in effect on the date of this inspection. Name of Firm 7 A o -e. --r, SOI( r Address ,;Zi.) 3 -/ /6- ' -oj L}hc 4 p e/ Air Telephone _275 -39/6 - Date No./ /, /gel/ (ENGINEER SEAL) 6. DHEP Approval Approved for /i/,6beds Approved Disapproved Terms of Conditional Approval .. � • n•• N. 2225-E: �' , !4 JUNE 2.'4 1371 �4aao�n.�t By Conditional CAUTION THE MUNICIPALITY OF ANCHORAGE DEPARTMENT OF HEALTH AND ENVIRONMENTAL PROTECTION (DHEP) ISSUES HEALTH AUTHORITY APPROVAL CERTIFICATES BASED SOLELY UPON THE REPRESENT- ATIONS GIVEN IN PARAGRAPH 5 ABOVE BY AN INDEPENDENT PROFESSIONAL ENGINEER REGISTERED IN THE STATE OF ALASKA. THE DHEP DOES THIS AS A COURTESY TO PURCHASERS OF HOMES AND THEIR LENDING INSTITUTIONS IN ORDER TO SATISFY CERTAIN FEDERAL AND STATE REQUIRE- MENTS. EMPLOYEES OF DHEP DO NOT CONDUCT INSPECTIONS OR ANALYZE DATA BEFORE A CERTIFICATE IS ISSUED. THE MUNICIPALITY OF ANCHORAGE IS NOT RESPONSIBLE FOR ERRORS OR OMISSIONS IN THE PROFESSIONAL ENGINEER'S WORK. RR4/ej/D18 [Page 2 of 2] (DHEP SEAL) 7-19-84 A. WELL DATA MUNICIPALITY OF ANCHORAGE (MOA) HEALTH AUTHORITY APPROVAL (HAA) CHECKLIST - FEBRUARY 1984 Legal Description: 2-0 7/0c� 3 MUNICIPALITY OF ANCHORAGp DEPT. OF HEALTH & ENVIRONMENTAL PROTECTION NOV 1984 RECEIVED �cr+�?�JSon 6-sfcs, Ti5rvniw rec... 3 Well Classification fe-i u4 If A, B, or C, D.E.C. Approved(Y/N) 6v/4, - Well Log Present (Y/N) l Date Completed 3/ice P Yield /.5-- Total 5Total Depth / z/e) Cased to /4/e ' Depth of Grouting /4 Static Water Level /c?% Pump Set At /.:R.‘ Casing Height Above Ground a % / Sanitary Seal on Casing (Y/N)/1/ Electrical Wiring in Conduit Depression Around Wellhead (Y/N) Separation Distances from Well: To Septic/Holding Tank on Lot lot) / ; On Adjoining Lots /lo 7` To Nearest Edge of Absorption Field on Lot /Dat ; On Adjoining Lots /r>o To Nearest Public Sewer Line 4/o, To Nearest Public Sewer y Cleancut/Manhole 410'"e-- To Nearest Sewer Service Line on Lot 75- Water S Water Sample Collected ByF., , e ; Date /a/6-/.4/ Water Sample Test Results s Gfoev^y Convents B. SEPTIC/HOLDING TANK DATA Date Installed 2f15-' ( Size /mora G-5 L No. of Ccupartnents off. Standpipes (Y/N) / Air -tight Caps (Y/N) Y Foundation Cleanout (Y/N) Depression over Tank (Y/N) /V Date Last Pumped /Yew Pumping/Maintenance Contract on File (Y/N) '1/4 ; for Holding Tank High -Water Alarm (Y/N) //7/,4 Temporary Holding. Tank Permit (Y/N) /L"%1 Separation Distances from Septic/Holding Tank: To Water -Supply Well /6D 7` To Building Foundation To Property Line /d t To Disposal Field .6". To Water Main/Service Line VS- To Stream, Pond, Lake, cr Major Drainage Course /7/vn e Comments iSDc 11 '1 vcsy [Page 1 of 2] 2-15-84 C. ABSORPTION FIELD DATA Soils Rating in Absorption Strata /5.v Type of System Design 74 -Ye nc h Date Installed Width of Field Square Feet of Absorption Area Depression over Field (Y/N) /IJ Results of Last Adequacy Zest Ne w Length of Field 4`s Depth of Field /e2 Gravel Bed Thickness 5 4'o Standpipes Present (Y/N) )' Date of Last Adequacy Test tie} Separation Distance from Absorption Field: To Water -Supply We11 /2 f To Building Foundation 2e) r COY.s1�. To Property Line 678/ To Existing or Abandoned System Lot /Va - C ; On Adjoining Lots 3e2 To Water Main/Service Line /D ' To Cutbank(if present) /t/d-2-1 To Stream/Pond/Lake/or Major Drainage Course To Driveway, Parking Area, or Vehicle Storage Area 74-,/e2 / Comments D. LIFT STATION Date Installed Size in Gallons "Pump On" Level at High Water Alarm Level at Tested for Electrical Codes(Y/N) Comments Dimensions Manhole/Access (Y/N) "Pump Off" Level at Vent (Y/N) Pumping Cycles curing Adequacy Test. Lets NIDA ** Check Permitted Bedroom Rating Against HAA Request ** I certify that I have checked, verified, or conforned to all MOA HAA Guidelines in effect on the date of this inspection. Signed Company KB1/d5/s Date No,/ 7 /9e/ 7 i -, 5ik dr ( PG .MOA No. Sy —Stull [Page 2 of 2] 2-15-84 ` v . PtT ± w.eY a s/ 3 iv arw 5.7 AS -BUILT I hereby certify that I have surveyed the following described property: J P f 7 151" k" i E4f.e<'a•;_. 3 t A.1 ;`*•91 Anchorage Recording Precinct, Alaska, and that the improve- ments situated thereon are within the property lines and do npt. overlap or encroach on the property lying adjacent thereto, that no improvements on property lying adjacent thereto encroach on the premises in question and that there are no roadways, transmission lines or other visible easements on said property except as indicated hereon. Dated at Eagle River, Alaska this_j day of -5--a 0 19 'G%• ROBERT C. JOHNSON7t" .` r e SCALE: Registered. Land Surveyor No. $80 -LS 1" - Box 77-0456, Eagle River, Alaska 99577 Phone (907) 694-2543