Loading...
HomeMy WebLinkAboutT15N R1W SEC 8 LT 10TI N I lW eC. 8 Lot 10 051-092 -18 MUNICIPALITY OF ANCHORAGE On -Site Watmr& Wastewater Program POBox 190O5O 4rOOElmore Road Anchorage, Alaska 9V519-685O Phone: 904 Fax: (9O7)343'rV87 h«p:0wvwv.muni.org/onodo On -Site Wastewater Disposal System Permit Permit Number: O8P281142 Work Type: Septic Upgrade Tax Code Number: 05109218800 Site Legal Address: T15NR1VVSEC 8LT 10 G:1357 Site Mailing Address: 21024CR\BTREE8T.Chugiak Owner: CHANDLER ROBERTF&PATR|CEK4 Dmm|0m Engineer: FIRST WATER CONSULTING This permit iwfor the construction of: 21 Disposal Field 10 Septic Tank [] Holding Tank [] Privy Effective Date: Expiration Date: Lot Size in Sq Ft: Total Bedrooms: 6/10/2026 6/10/2027 Non -Public 171 Water Well El Water Storage All construction shall be|maccordance with: 1. The attached approved design. 2. All requirements specified in Anchorage Municipal code Chapters 15.55ond 15.66and the State ofAlaska VVoetovvabar Disposal Regulations (1 8AAC72) and Drinking Water Regulations (1 8AAC80) 3. The wastewater code requires inspections during the installation. The engineer ahaUnuUfvthmDeve|opment Gan/ioes Department per AMC 15.05. Coodinotuvvith On -Site staff regarding preferred method. 4. From October 15 to April 15, a subsurface soil absorption system under construction during freezing weather shall bneither: e. Opened and Closed onthe same day, nr b. Covered, sealed, and heated to prevent freezing Issued To: FIRST WATER CONSULTING Issued By: Curtis Townsend Date: 6/10/2020 Date: 6/10/2026 4 MUNICIPALITY OF ANCHORAGE i_ Development Services Department �\f Phone: 907-343-7904 On -Site Water & Wastewater Section ON -SITE SEPTIC/WELL PERMIT APPLICATION Parcel I.D. 051-092-18 Property owner(s) ROBERT & PATRICE CHANDLER Day phone Mailing address 21024 CRABTREE STREET, CHUGIAK, AK 99567 Site address 21024 CRABTREE STREET, CHUGIAK, AK 99567 Legal description T15N R1 W SEC 8 LOT 10 Number of Bedrooms 4 Engineering Firm FIRST WATER CONSULTING Building Permit Number Not Applicable❑ APPLICATION IS FOR: APPLICATION IS AN: (® all that apply) Disposal Field Initial ❑ Septic Tank Upgrade Holding Tank ❑ Renewal ❑ Privy ❑ Well ❑ Water Storage ❑ THIS APPLICATION INCLUDES A WAIVER REQUEST FOR: Permit/Rush Fees: Date of Payment: Permit No. `t� Waiver Fees: Date of Payment: Waiver No. Distance: May 2025 13030 Sues Way, Anchorage, AK 99516 907-350-9566 / FirstWaterAK@gmail.com ! !! June 1, 2026 Municipality of Anchorage On-Site Water & Wastewater Program 4700 Elmore Road Anchorage, AK 99507 RE: SEPTIC SYSTEM UPGRADE PERMIT LEGAL: T15N R1W SEC 8 LOT 10 The property owner has requested we obtain a permit to upgrade the failed septic system of the above referenced lot. The proposed design is to install an anchored AdvanTex FAP 3.0 & pump basin (PB) along with an elevated mounded bed with with 2’ of MOA sand. Although this is an existing, 3 -bedroom residence, a 4-bedroom system is proposed for current functionality and future flexibility. The design is based on the recent test hole conducted in May 2026 which results are attached. Groundwater was observed in the hole at 2.5’during excavation and at 2’ at monitoring in May 2026. A separation of 3’ has been designed to the monitored groundwater. The area in general has shallow groundwater with fast percolating shallow soils. The slopes are flat or very moderate at 0-5% at the proposed upgrade location. The lot and area are served by private water. The design will not impact any of the neighboring properties. Please contact us if you have any questions. Sincerely, Curtis Huffman, P.E. Municipality of Anchorage On-site Water and Wastewater REVIEWED FOR CODE COMPLIANCE OSP261142, Curtis Townsend, 06/10/26 FIRST WATER CONSULTING T15N R1W SEC 8 LOT 10 DESIGN CALCS: NO SLOPES >25% WITHIN 50'OF PROPOSED FIELD. STAKE PROPERTY LINES, WELL RADII, ESMTS, OR OTHER SEPARATIONS... PRIOR TO CONST. Municipality of Anchorage On-site Water and Wastewater REVIEWED FOR CODE COMPLIANCE OSP261142, Curtis Townsend, 06/10/26 FIRST WATER CONSULTING NO WELLS WITHIN 50' OF PROPOSED SEPTIC SYSTEM. AREA SERVED BY PRIVATE WATER. DESIGN DETAILS: T15N R1W SEC 8 LOT 10 Municipality of Anchorage On-site Water and Wastewater REVIEWED FOR CODE COMPLIANCE OSP261142, Curtis Townsend, 06/10/26 3030 Sues Way - Anchorage, Alaska 99516 Tel. 907-350-9566 FirstWaterAK@gmail.com SOILS LOG - PERCOLATION TEST LEGAL : T15N R1W SEC 8 LOT 10 PERFORMED BY: FWC - I CURTIS HUFFMAN CERTIFY THAT THIS TEST WAS PERFORMED IN ACCORDANCE WITH ALL STATE & MUNICIPAL GUIDELINES IN EFFECT ON THIS DATE: 05/29/2026 DEPTH FEET OG SOILS 1 ORG/OL 2 3 GW w/ cobbles- boulders. 4 5 6 ML 7 8 BOH 9 10 11 12 13 14 15 16 17 18 19 20 Reading Date Gross Time Net Time Depth to Water Net Drop 05/22/26 2 min 6” 6” “ 6” 6” “ 6” 6” PERCOLATION RATE <1 (MIN / INCH) TEST RUN BETWEEN 1 & 2 FT PERC HOLE DIAMETER 6” PRE-SOAKED PRIOR TO TEST & ALL READINGS TO THE 1/16TH. GROUND WATER ENCOUNTERED: YES IF YES, AT WHAT DEPTH: 2.5’ DEPTH TO WATER AT MONITORING: 2’ DATE: 05/29/2026 TESTHOLE # 26-1 DATE PERFORMED: 05/22/2026 SEE SITE PLAN FOR SLOPE & LOCATION COMMENTS: VERY RAPID PERCOLATING SOILS – INSTALL FILTER & FOR SEPARATION. VERIFY GROUNDWATER MT AT TIME OF CONSTRUCTION PERFORMED FOR: ROBERT & PATRICE CHANDLER 05/29/26 Municipality of Anchorage On-site Water and Wastewater REVIEWED FOR CODE COMPLIANCE OSP261142, Curtis Townsend, 06/10/26 MUNICIPALITY OF ANCHORAGE ADVANCED WASTEWATER TREATMENT SYSTEM MAINTENANCE AND REPAIR AGREEMENT THIS MAINTENANCE AND REPAIR AGREEMENT, herein the "AGRLEMENT" made and entered into as of this (7-0" bayofI-ole, of 20 --Ro, by and between /A.6e-rV UaAlerein the "OWNER," and the Municipality of Anchorage, herein the "MUNICIPALITY", in accordance with Anchorage Municipal Code (AMC) 15.65.365. In consideration of the mutual covenants contained herein, the parties to this Agreement agree as follows: 1. Advaneed Wastewater Treatment Systems. The Municipality grants permission to the Owner to utilize and operate an Advanced Wastewater Treatment System (AWWTS), described as AN ADVANTEX SYSTEM located at (legal description) T15N R1W SEC 8 LOT 10 2. Maintenance. Repairs and Alterations. (Owner is required to read, understand and -Initial each section) PL— Throughout the term of this Agreement, the Owner shall enter into a service agreement with an AWWTS service and maintenance provider approved by the Municipality or the manufacturer's representative. The AWWTS shall be maintained in a satisfactory condition capable of performing as designed and producing treated septic effluent in accordance with the equipment's approval for operation in the Municipality. It shall be the responsibility of the Owner during the term of this Agreement to pay for all P-C repair(s), maintenance, adjustment(s), replacement costs, and inspection costs. This includes an annual maintenance fee (typically $400 to $600). PC Owner agrees that only maintenance and repair personnel approved by the Municipality AC or the manufacturer's representative will inspect and make any necessary maintenance, repairs or permitted alterations to the system, PC Owner acknowledges that regular maintenance of an AWWTS reduces the potential /'QC- failure of the system, which could include sewage backup and costly repairs or drainfield replacement. (rev. 05/18/2018) Page I of 3 n, M_ Owner acknowledges that the Municipality may request records of maintenance and AC repairs from the manufacturer's representative or maintenance provider. ,Rr VOwner acknowledges that the fine for failing to maintain and repair an AWWTS may be 1411C assessed in accordance with AMC 14AO.030. Pr Owner agrees to grant the Municipality reasonable access to test and inspect the R(' AWWTS. The Municipality will give at least 24-hour notice. PL Owner agrees that any sale or transfer of title of the property will not occur without a new 11�k Certificate of On -Site Systems Approval. Owner agrees that the AWWTS installation and maintenance requirements as provided by the AWWTS vendor/installer and approved by the Municipality are the governing guidelines for the construction, maintenance and repair of the Owner's AWWTS. Owner agrees to maintain remote monitoring of the AWWTS as required by the AW)WTS approval. 3. Term. The term of this Agreement shall begin on the date of approval by the Municipality to operate the installed system, or upon transfer of title, and shall continue while the AWWTS is operational or until title is transferred. 4. Nonwaiver. The failure of the Municipality at any time to enforce a provision of this Agreement shall in no way constitute a waiver of the provisions, nor in any way affect the validity of the Agreement or any part hereof, or the right of the Municipality thereafter to enforce every provision hereof. 5. Amendment. This Agreement shall only be amended by authorized representatives of the Owner and Municipality. Any attempt to amend this agreement by either an unauthorized representative or unauthorized means shall be void. 6. Ju[W:wIWn: Choice of Law. Any civil action arising from this Agreement shall be brought in the Superior Court for the Third Judicial District of the State of Alaska at Anchorage. The laws of the State of Alaska shall govern the rights and obligations of the parties under this Agreement. 7, Severabilill. Any provisions of this Agreement decreed invalid by a Court Of competent jurisdiction shall not invalidate the remaining provisions of the Agreement. (rev. 05/18/20 18) Page 2 of 3 OWNER: /� C/,,*- -. a, (- 6Ct By: (signature) Pcr ici CI �c`�c�le P,uac, (fY .�I�f (print name) STATE OF ALASKA ) ss. THIRD JUDICIAL DISTRICT ) Date:.. 5 S" N 2 2cz f The foregoing instrument was acknowledged before me this 61 day of 3'4"'p' 20 Lam, by ,'('(: Gf, 1 0,&>3ff-rt C Na-O fr-r f NOTARY PTATILIC FOR XLASKA My Commission expires: it f OV -Zola HUNTER u RTH State of Alaska My Commisslon Expires Nov 7, 2029 MUMCIPALITY: r� By: (signature) (rev. 05/ 18/2018) Date:Z- int name) Title: C( V tL C'*-' C / f.-;,2 Page 3 of 3 0 LI 00 ry N 0 O N � O N 0 O n O d- 0 0 Z° O 0 Z N 89 47 51 W 332.26 �N90000'00"VI� 330.10' REC) X 00 LOT 10 SEPTIC • PIPE (tYp) , ,moo o, �, > >� 53.6' EXISTING BUILDING LO 10 - WELL WELL ® 2.5o C6 5.0' WN PAVED WALK QGRAVEL 0 ct N I D /W 50' R.O.W. RESERVE STORAGE N 24.3' o0 VALLEY AVE (NOT BUILT) FIREWOOD / r7 N89°53'41 "W 332.40' (N90-OO)OO"W 330.07' REC) ANCHORAGE RECORDING DISTRICT, ALASKA AS -BUILT OF: BLM LOT 10 T15N R1W Sec 8 S.M. SURVEY CERTIFICATE: I, John L. Schuller, Have conducted a physical survey of this property as shown on this drawing and that the improvements situated hereon are within the property lines and no enchroachments exist other than noted. Under no circumstance shoull any information on this drawing be used for construction of fences, structures, improvements, or for establishing boundary lines. EXCLUSION NOTES: It is the owners responsibility to determine the existence of any easements, covenants, or restrictions which do not appear on the recorded subdivision plat. WORK ORDER NUMBER: DATE: SCALE. E—MAIL: OCT 27, 2025 1 "=50' schullerak®gmail.com 2 5 —13 6 DRAWN BY. CHECKED BY GRID NUMBER: BOOK AGE: JLS NW1357 250409 85.6' w w O Iz 0 Ln 26.0' `�F7PADL___j -$- = FND MONUMENT NOTE: 1. Record Information per Dependent Resurvey = FND 5/8" REBAR Dated May 13, 1955 AW OF �\ / �': • � 4 9TH �.......... ....... ..... .....� co •.J N L. SCHULLER.• 0 / ` LS-10408 ew / ap ... �a low`\ ro fesslo nod �o.� .► \\\"`��► �m L A Nil?) STT �T �,� o s � 1831 Talkeetna Street Anchorage, Alaska 99508 (907) 227-1455 office (907) 274-4992 fax GRE! ANCHORAGE AREA Department of Environmental Quality 3330 C Street Anchorage, Alaska 99503 INSPECTION REPORT ON-SITE SEWAGE DISPOSAL SYSTEM NAME LOCATION MAILING ADDRESS. PHONE LEGAL DESCRIPTION [~ I0 ~. ~ T/FA/~lt~/~,,~/. SEPTIC TANK: DISTANCE FROM WELL INSIDE LENGTH ~JL'~ 17'~ Iql MANUFACTURER NUMBER OF MATERIAL GTC COMPARTMENTS Z. INSIDE WIDTH LIQUID DEPTH I IQUID CAPACITY /.,~ ~'0 GALLONS. SEEPAGE PIT: NUMBER OF PITS DIAMETER LINING MATERIAL ~ell(.~,~{-~, CRIB SIZE: BUILDING FOUNDATION__ OR WIDTH '~'~, LENGTH ~Z'. DEPTH ~ ' ,+' 3~ DIAMETER DEPTH DISTANCE FROM: WELL /~ 4, TOTAL EFFECTIVE NEAREST LOT LINE ABSORPTION AREA (WALL AREA) ~ SQ. ~. ADDITIONAL ABSORPTION WELL: TYPE a, ltJ CONSTRUCTION BUILDING '"'~ * NEAREST FOUNDATION LOT LINE CESSPOOL OTHER SOURCES APPROVED DISAPPROVED NEAREST SEWER LINE REMARKS DEPTH DISTANCE FROM: SEPTIC e,(-.~' SEEPAGE //7~,, TANK , SYSTEM . DISTANCES= INSTALLED BY= -. PIPE MATERIAL= LOT SLOPE: Form NO. EQ-031 Performed For ~ ~ur~' Legal Description: Lot (0 Bloc~ This Form Reports Soils Log ~ GREATER ANCHORAGE AREA BOROUGH DEPARTMENT OF ENVIRONMENTAL QUALITY Case # 3330 "C" Street ANCHORAGE, ALASKA 99503 (~'~&~J~"~'~ed Performed '~ -I- Subdivision~. ~ ~1~ Percolation Test - Soil TestyMust Be Logged Depth / Feet Soil Characteristics To 4' Below Proposed Seepage System - 11-- 12-- 13-- 14-- Was Ground Water Encountered? If Yes, At What Depth? Reading Date Gross Time Net Time Depth to H20 Net Drop Percolation Rate Minute Proposed Installation: Seepage Pit Depth of Inlet .Depth to COMMENTS: Drain Field Bottom of Pit br Trench Test Performed BY "~'~^ ~ -~-- Date Certified BY: Date: Municipality of Anchorage Development Services Department , Building Safety Division On-Site Water & Wastewater Program 4700 B!~agaw~ S~re~t P.O. Box 196650 Anchorage, AK 99519-6650 www.muni.org/onsite (907) 343-7904 CERTIFICATE OF ON,SITE SYSTEMS APPROVAL FOR A SINGLE FAHILY DWELLING Parcel I,D. 051-092-18 1. GENERAL INFORMATION COSA# 0 ~¢-~ Expiration Date: Complete legal description Location (site address) Current Property owner(s) Mailing address Lending agency Mailing address Real Estate Agent Mailing address T15N, RlW, SECTION 8; LOT 10 21024 CRABTREE STREET * CHUGIAK~ AK * 99567 JASON RYZNAR Day phone 21024 CRABTREE STREET * CHUGIAK, AK * 99567 Day phone 947-1005 BROOKE STILTNER W/ REMAX Day phone 748-0156 110 W. 38TH AVENUE, #100 * ANCHORAGE, AK *99503 Unless otherwise requested, COSA will be held by DSD for pickup. NUMBER OF BEDROOMS: 4 3. TypE OF WATER SUPPLY: TYPE OF WASTEWATER DISPOSAL: Individual Well · Individual On-site · Individual Water Storage [] Individual Holding tank [] Community Class Well [] Community On-site [] Public Water System [] Public Sewer [] The Municipality of Anchorage Development Services Department (DSD) Issues Certificates of On-Site Systems Approval (COSA) based only upon the representations given in paragraph 4 by an independent professional civil engineer registered in the State of Alaska. Certificates of On-Site Systems Approval are required for the transfer of title (except between spouses) for properties served by a single-family on-site wastewater dispesal and/or water supply system. DSD also issues COSAs upon request to homeowners. Certificates of On-Site Systems Approval are valid for 90 days from the date of issue for properties served by a private or Class C well and may be reissued with new water samples. (Certificates may be reissued for a period of up to one year with valid water samples.) Certificates are valid for one year for properties served by Class A or B wells or a public water system. The Municipality of Anchorage is not responsible for errors or omissions in the professional engineer's work. 4. STATEMENT OF INSPECTION BY ENGINEER As certified by rny seal affixed hereto and as of ,,,~.va,t,o,ion d,=, .... ~,v,,, below, I verify,,,o,'~-~+ ,,u,'~" investigation, based on procedures outlined in the Certificate of On-Site Systems Approval Guidelines for this application, shows that the on-site water supply and/or wastewater disposal system is (are) safe, functional and adequate for the number of bedrooms and type of structure indicated herein. I further verify that based on the information obtained from the Municipality of Anchorage files and from my investigation and inspection, the on-site water supply and/or wastewater disposal system is(are) in compliance with all applicable Municipal and State codes, ordinances, and regulations in effect at the time of installation. Name of Firm GARNESS ENGINEERING GROUP, Ltd. Phone 557-6179 Address 5701 E. TUDOR ROAD, SUITE 101 * ANCHORAGE, AK 99507 Engineer's Printed ~a-"~rne JEFFREY .A. GARNESS, P.E. Date Engineer's Comments: In conducting this evaluation, GEG, LtD. attempted to provide a thorough, conscientious engineering analysis of the system in accordance with ADEC and MOA DSD Guidelines & Regulations. The reported results described the performance of the system under the conditions encountered at the time of the test, and separation distances measured to readily identifiable features. The operational life of all wells and septic systems depend on the local soils condition, groundwater levels that may fluctuate during the year, and the water usage of the family being served by the system. These conditions are outside the control of the evaluator of the system. Satisfactory test results do not guarantee future performance of the system, nor do they guarantee that there are no hidden defects or encroachments. GEG, LTD. can therefore not provide any warranty or future estimate of how long the system will continue to meet the operational requirements of the ADEC or MOA DSD. The content of this report is for the sole benefit of the owner listed above. Any reliance upon or use of this report by any other person or party is not authorized, nor will it confer any legal right whatsoever. DSD SIGNATURE Approved for ~ Disapproved. Conditional approval for bedrooms. bedrooms, with the following stipulations: Attachments: COSA Checklist Septic System Advisory U/' Well Flow Advisory Arsenic Advisory. Maintenance Agreements Supplemental Engineer's Report utner Original Certificate Date: Municipality of Anchorage Development Services Department Building Safety Division On-Site Water & Wastewater Program 4700 Bragaw Street P.O. Box 196650 Anchorage, AK 99519-6650 www.muni.org/onsite (907) 343-7904 CERTIFICATE OF ON-SITE SYSTEMS APPROVAL CHECKLIST Legal Description: T15N, R1W, SECTION 8; LOT 10 Parcel ID: A= WELL DATA *PER GEG Well type PRIVATE Date completed ~ 1973 Total depth *77+ ft. INSPECTION. **PER AAROW If A, B, or C provide PWSID# N/A Sanitary seal (Y/N) YES Cased to **48+ .ff. PUMP AND WELL INSPECTION. SEE ATTACHED REPORT. Well LOg (Y/N) Wires properly protected (Y/N) Casing height (above ground) NO YES 12+ ,in. FROM WELL LOG Date of test Static water level ff. Well production ..--'"" g,p.m. AT INSPECTION 9/9/2010 57 3.57 g.p.m. B= WATER SAMPLE RESULTS: Coliform ~.~ colonies/100 mi. ArSenic: 1{o L~ ug./L. SEPTIC/HOLDING TANK DATA Tank TYpe/Material SEPTIC/STEEL Tank size 1250 gal. Number of Compartments Foundation cleanout (Y/N) YES Date of pumPing 6/30/2010 Nitrate O. { mg./L. Date of sample: 9/9/2010 2 Depression over tank (Y/N) NO Pumper Other bacteria Collected by: __ colonies/100 mi. GEG Ltd. Date installed 10/3/197,9 Cleanouts (Y/N) YES High water alarm (Y/N) N/A SANITARY PUMPERS ABSORPTION FIELD'DATA I'BELOW EXISTINC (~RADEI Date installed 10/3/197,9 Soil rating (g.p.d./ft2o~ 85 System type SEEPAGE PIT Length 32 .ft. Width 22 .ft. Gravel below pipe 3 .ft. Total de; Eft. absorption area 524 ft2 Monitoring tube YES Depression over field NO For 3 bedrooms New depth 35 in. 450+ g.p.d. Any rejuvenation treatment (past 12 mo.) (YIN & type) NONE KNOWN If yes, give date - NOTE: ST2 WAS NOT PRESENT. APPROVED AS IS PER 9/10/2010 CONVERSATION W/ JEFF POET. Date of adequacy test 9/9/2010 Results (Pass/Fail) PASS Fluid depth in absorption field before test 32 in. Water added 780 gal. Elapsed Time: 875 min. Final fluid depth ,32 in. Absorption rate >= D. LIFT STATION Date installed "Pump on" level at__ E. Size in gallons Manhole/Access in. "Pump off" lev~ High water alarm level at Cycles tested SEPARATION DISTANCES SEPARATION DISTANCES FROM WELL ON LOT TO: Septic tank/lift station on lot Absorption field on lot Public sewer main Sewer/septic service line Animal containment areas '50'+ *'100'+ N/'A in. 50'+ Meets alarm & circuit requirements? On adjacent lots 100'+ On adjacent lots 100'+ Public sewer manhole/cleanout Holding tank N/,A Manure/animal excrete storage areas N/A 100'+ SEPARATION DISTANCES FROM SEPTIC/HOLDING TANK ON LOT TO: Building foundation 5'+ Property line 5'+ Water main N/,A Water service line 10'+ Wells on adjacent lots 100'+ SEPARATION DISTANCE FROM ABSORPTION FIELD ON LOT TO: Property line 10'+ Water service line 10'+ Curtain drain NONE KNOWN Absorption field Surface water. 5'+ 100'+ Building foundation. 10'+ Surface water. 100'+ Wells on adjacent lots. 100'+ Water main N/,A Driveway, parking/vehicle storage 10'+ COMMENTS *TANK WAS APPROVED ON 10/,,3/,1973. CODE CHANGED 10/,197.3 *'106' FROM WELL TO CLOSEST STANDPIPE. 100' PER 10/,,5/,1975 INSPECTION REPORT. G. ENGINEER'S CERTIFICATION I certify that I have determined through field inspections and review of Municipal records that the above systems are in conformance with MOA COSA guidelines in effect on this date. Engineer's Printed/Name! JEFFREY A. GARNESS Date C~,/7~ ~//O COSA Fee ~ Date of Payment Receipt Number (Rev. 11/05) Waiver Fee $ Date of Payment Receipt Number Municipality of Anchorage Development Services Department Building Safety Division On-Site Water and Wastewater Program 4700 Elmore Street P.O. Box 196650 Anchorage, AK 99519-6650 www. ci. anchorage, ak.us (907) 343-7904 Septic System Advisory Certificate of On-Site Systems Approval # 101225 During a recent adequacy test on the septic system for Block , Lot 10 of T15N R1W Section 8 subdivision, 32 inches of standing water was observed in the absorption field. This indicates that approximately 89% of the absorption area is inundated. Although this system passed the adequacy test, the remaining life expectancy may be limited. This advisory must be attached to all copies of the subject Certificate of On- Site Systems Approval Municipality of Anchorage Development Services Department Building Safety Division On-Site Water and Wastewater Program 4700 Elmore Street P.O. Box 196650 Anchorage, AK 99519-6650 www.muni.org/onsite (907) 343-7904 Arsenic Advisory Certificate of On-Site Systems Approval # 101225 A Certificate of On-Site Systems Approval inspection and test of potable water was recently conducted on the well water supply on Block , Lot 10 of T15N R1W Section 8 Subdivision. This inspection revealed an arsenic concentration of 11.4 micrograms per liter (ug/L) for the property's well water sample. The Environmental Protection Agency (EPA) has established a maximum contaminant level (MCL) of 10.0 ug/L for public drinking water systems. While private wells are not subject to this regulation, EPA standards are based on existing health information and can therefore be used to gauge the relative quality of water from private wells. Information on arsenic is available from the On-Site Water and Wastewater Program website (www.muni.org/onsite) or at 343-7904. This advisory must be attached to all copies of the subject Certificate of On- Site Systems Approval. SGS ReL# 1104847001 Client Nam~ Garness Engineering Group, Ltd Printed Date/Time 09/21/2010 16:51 Project Name/# T15N,R1W,SEC~8,L10 Collected Date/Time 09/15/2010 11:20 Client Sample ID T15N,R1W,SEC~8,LI 0 Received Date/Time 09/15/2010 12:26 Matrix Drinking Water Technical Director Stel~hen C. Ede Sample Remarks: Allowable Prep Analysis Parameter Results LOQ Units Method Container ID Limits Date Date Init Metals by ICP/MS Hardness as CaCO3 ND 5.00 mg/L SM20 2340B B 09/17/10 09/20/10 KDC Private Individual Analysis Alkalinity 151 I0.0 mg/L SM20 2320B A 09/15/10 LP Aluminum 87.1 20.0 ug/L EP200.8 B 09/17/10 09/20/10 KDC Antimony ND 1.00 ug/L EP200.8 B (<6) 09/17/10 09/20/10 KDC Arsenic 9.29 5.00 ug/L EP200.8 B (<10) 09/17/10 09/20/10 KDC Barium 11.6 3.00 ug/L EP200.8 B (<2000) 09/17/10 09/20/10 KDC Cadmium ND 0.500 ug/L EP200.8 B (<5) 09/17/10 09/20/10 KDC Calcium 1380 500 ug/L EP200.8 B 09/17/10 09/20/10 KDC Chloride 10.9 0.100 mg/L EPA300.0 A (<250) 09/16/10 09/17/10 SDP Chromium ND 2.00 ug/L EP200.8 B (<100) 09/17/10 09/20/10 KDC CO3 Alkalinity 42.1 10.0 mg/L SM20 2320B A 09/15/10 LP Conductivity 333 1.00 umhos/cm SM20 2510B A 09/15/10 LP Copper 18.0 1.00 ug/L EP200.8 B (<1300) 09/17/10 09/20/10 KDC Fluoride 0.227 0.100 mg/L EPA 300.0 A (<2) 09/16/10 09/17/10 SDP HCO3 Alkalinity 109 10.0 mg/L SM20 2320B A 09/15/10 LP Iron ND 250 ug/L EP200.8 B (<300) 09/17/10 09/20/10 KDC Lead 0.252 0.200 ug/L EP200.8 B (<15) 09/17/10 09/20/10 KDC Magnesium 330 50.0 ug/L EP200.8 B 09/17/10 09/20/10 KDC Manganese 1.78 1.00 ug/L EP200.8 B (<50) 09/17/10 09/20/10 KDC Nickel ND 2.00 ug~ EP200.8 B (<100) 09/17/10 09/20/10 KDC OH Alkalinity ND 10.0 mg/L SM20 2320B A 09/15/10 LP pH 9.20 * 0.100 pHunits SM20 4500-HB A (6.5-8.5) 09/15/10 LP Selenium ND 5.00 ug/L EP200.8 B (<50) 09/17/10 09/20/10 KDC Silver ND 1.00 ug/L EP200.8 B (<100) 09/17/10 09/20/10 KDC Sodium 78100 500 ug/L EP200.8 B (<250000) 09/17/10 09/20/10 KDC Aarow Pump & Well Service'LLC (907)346-9355 Inspection Report 21024 Crabtree, Chugiak Well was inspected by camera to 48'. No perforations were found. Brian R. Wille Aarow Pump & Well Service LLC ASBUILT SEWARD & ASSOCIATES LAND SURVEYING 694-0829 :STRICTIONS ~/~r~ ~.~~~~~ ...... I HEREBY CERTIFY THAT I HAVE FOLLOWING DESCRIBED PROPERT' AND THAT NO ENCROACHMENTS INDICATED. IT IS THE RESPONS!BI OWNE3R TO DETERMINE THC EXiS' EASEMENTS, COVENANTS~ OR RE~ WHICH DO NOT APPEAR ON THE VISION PLAT. UNDER NO CIRCUMSTA ANY DATA HEREON BE USED FOR OF FENCE LINES, OR FOR ESTABI ARY LINES.