No preview available
HomeMy WebLinkAboutT15N R1W SEC 8 LT 30TT6A)MiuJ sac8 Lct 30 July 3, 2002 Municipality of Anchorage George P. Wuerch, Mayor Building SafeB- Division P.O. Box 196650 · 4700 S: Bragaw Street Anchorage, Alaslm 99519-6650 · (907) 845-8801 http://www, ci.anchomgc.ak.us Joseph & Julie Grohs PO Box 671512 Chugiak AK 99567 Subject: On-Site Water and/or Wastexvater Permit.' Permit Number: SW010317 ~L~l~/i~ 'D~s'~riptioni T15N.RI w. Secti0n 8 Lot 30 Dear Joseph & Julie Grohs: An On-Site Water/Wastewater Permit, number SW010317, issued by this office for a single-family system, will expire on August 13, 2002. This permit was valid for 365 calendar days. If this ~vas a well permit and the well has been drilled, a well log must be sent to this office for documentation of the installation and to close the permit. If this permit was for a wastewater disposal system, an original as-built inspection report must be sent to this office for review, approval and documentation. This as-built inspection report must be signed by the licensed Professional Engineer who inspected the installation of the system. As-built inspection reports are required to be submitted within 30 days of the completion of the system. If no system xvas installed under this permit, and you are still planning to install a well or xvastewater disposal system, a new permit must be obtained from this office. A new permit for a second year may be issued for a fee orS100.00 if the renewal application is received on or before the expiration date of the original permit. When applying for a new permit, the fees are: $400.00 for a wastewater permit and $150.00 for a well permit. If you have any questions, please call this office at 343-7904. On-Site Water and Wastewater Program Enc: Copy of permit MUNICIPALITY OF ANCHORA GE Development Services Department On-Site Water & Wastewater Program 4700 South Bragaw Street P.O. Box 196650, Anchorage, AK 99519-6650 (907) 343-7904 ON-SITE WASTEWATER DISPOSAL SYSTEM I WATER SUPPLY PERMIT Initial Date Issued: Aug 13, 2001 Expiration Date: Aug 13, 2002 Permit Number; SW010317 Legal Description:i',T15N R1W SEC 8 LT 30 , Design Engineer: 0024 Eagle River Engineering Services Owner Name: Joseph & Julie Grohs Owner Address: PO Box 671512 Chugiak, AK 99567-0000 Parcel ID: 051-091-21 Site Address: 021322 BIRCHWOOD LOOP RD Lot Size: 108900 SQ. FT. Total Bedrooms: 3 Permit Bedrooms: 3 This permit is for the construction of: [~] Disposal Field r~ septic Tank [] Holding Tank [] Privy ~-~ Private Well [] Water Storage All construction must be in accordance with: 1. The attached approved design. 2. All requirements specified in Anchorage Municipal Code Chapters 15.55 and 15.65 and the State of Alaska Wastewater Disposal Regulations ( 18AAC72 ) and Drinking Water Regulations ( 18AAC80 ). 3. The engineer must notify DSD at least 2 hours prior to each inspection. Provide notification by calling (907) 343-7904 ( 24 hours ). ( Not required for a Water Supply Permit only ). 4. From October 15 to April 15, a subsurface soil absorption system under construction during freezing weather must be either: A. Open and closed on the same day. B. Covered, sealed, and heated to prevent freezing. Received By: ~,~ .~)~ Date: Municipality of Anchorage Development Services Department Building Safety Division On-Site Water and Wastewater Program 4700 South Bragaw St. P.O. Box 196650 Anchorage, AK 99519-6650 www.ci.anchorage.ak.us (907) 343-7904 ON-SITE SEWER/VVELL PERMIT APPLICATION FOR A SINGLE FAMILY DWELLING Parcel I.D. ~ i---- O~/- o~. I Permit Number ,SWOlO~l 7 Property owner(s),JE)~.~--p/-( Mailing address (1) ?O ~ Mailing address (2) Legal description (Lot, Block & Sub'd.) (.O'{- ~ Legal description (Section, Township & Range) ,...,~C. ~ Lot Size IO'~?l~) Acres/S ._a~. Day phone Zip Code Number of Bedrooms THIS THIS APPLICATION IS FOR: Sewer Only I-'] Well Only r-] Sewer and Well [~ Water Storage [] Sewer Upgrade I--] PROPERTY CONTAINS: Hot Tub [-] Jacuzzi [] Swimming Pool [--I Water Softening Unit [] Therapy Pool [] I certify that the above information is correct. I further certify that this application is being made for a Single Family Dwelling and is in accordance with applicable Municipal Codes. (Signature of property owner or authorized agent) Permit Fees: Date of Payment: Receipt Number: (Rev. 12/00} I- ! oo 7 Waiver Fees: Date of Payment: Receipt Number: Eagle River Engineering Services Louis Butera, P.E. P.O. Box 773294 (907) 694-5195 tel Eagle River, AK 99577-3294 (907) 694-3297 fax August 2, 2001 Jim Cross, P.E. Manager, On-Site Services Municipality of Anchorage P.O. Box 196650 Anchorage, AK 99519 Re: BLM Lot 30 T15N, R1W, Sec 8 Narrative & Permit Application Dem- Mr. Cross: The proposed well and septic system will have very limited ~mpact on adjacent properties for the ~,.~-~ following reasons:~ ~ The surrounding lots are large BLM 2.5 acre lots; soil has a high permeability rate, allowing sufficient room for several septic sites. 2. Immediate neighboring septic systems are all +30' distance. 3. ' The soil is adequate for leaching. Surface drainage will not be affected and is not a major consideration in our design. The surrounding lots are fully developed and have reserve sites therefore this septic system placement will not affect the development of any other lots surrounding this unit. We are in the process of applying for vacation of the 50' BLM,ROW.easement to the south. If you have any questions please call our office at 694-5195. Sincerely, Louis Butera, P.E. ~.001\01-027N^R. DOC N 8g'i.2'34'E: 328.8_I' / 100.0' NO SURFACE WATER '~~OT 35 WELL ~0 K~OW~ CURIN~ DRAINS 2ESERVE AREA NO WELLS OR SEPTICS +100 I~ - TEST HOLE · - MONITOR TUBE o - SEWER CLEAN OUT + - WELL EASEMENT PROPOSED LEACH FIELD · --"- EXISTING LEACH FIELD WELL/SEPTIC SITE PLAN LEGAL: LOT 30, T15N, R1W, SEC.8 OWNER: JOSEPH & JULIE GROHS CONTRACTOR: N/A JOB#Ol-O27WSI DATE: 8/1/01 ] SCALE 1" = 60' A EAGLE RIVER ENGINEER/NC SERVICES P.O. Box 773294 EAGLE RIVER, AK. 99577 (907) 694-5195 FAX: (907) 694-3297 Eagle River Engineering Services Louis Butera, P.E. P.O. Box 773294 (907) 694-5195 tel Eagle River, AK 99577-3294 (907) 694-3297 fax LEGAL: SPECIFICATIONS FOR ON-SITE SEPTIC SYSTEM BLM Lot 30 T15N, R1W, Sec 8 August 8, 2001 REV#1 A. GENERAL 1. The well and septic plan are for a 3 bedroom single family residence only. 2. The drawing and or site plan shall be a part of this specification. 3. All materials and workmanship shall meet the Anchorage Department of Health and State Department of Environmental Conservation requirements. 4. All soil tests are advisory to the design and are to be verified or modified in the field by the engineer. 5. All excavations and depths are advisory and are to be verified in the field by the contractor to meet Municipality of Anetiorage, Department of Environmental Conservation requirements. 6. It is the responsibility of the owner to obtain all necessary permits or easements and to locate any adjacent multi-family wells. 7. The excavation is to be exactly in the area shown on the site plan, any deviation requires engineer approval. -8. It is always recommended that a surveyor locate the nearest lot line position and the location of any easements. 9. Any remaining open test hole excavations shall be filled. B. SEPTIC TANK I. 1000 gallon minimum, MOA approved. C. DRAINFIELD BED I. The trench is to follow the natural land contour to maintain uniform total depth of the trench bottom. 2. The bottom of the trench excavation prior to rock placement shall be level, plus or minus 1.5". 3. The total depth of the trench excavation is not to exceed 4' at any point. 4. The effluent line within the trench shall be laid level within 0.03'. 5. The trench gravel is to be covered with typar fabric material. 6. Mounded soil or combination of soil and extruded board insulation to a depth oft or equivalent is to be placed over the leachfield. 7. The area over the trench is to be finish graded to prevent ponding of surface water runoff. 8. The septic tank and leaehfield must not be closer than 100' to any existing private well, 150' to any Class "C" well, or 200 feet to any community well. RECOMMENDED LEACHFIELD DIMENSIONS: TOTAL DEPTH = 4' GRAVEL DEPTH = 0.5' under pipe, 2" over pipe BED LENGTH = 38' BED WIDTH = 15' SOIL RATING = 0.8 GPD/ft2 BEDROOM CAPACITY = 3 SEPTIC TANK = 1000 gallon MINIMUM Twenty-four (24) hours notice required for all inspections. k2001 \01.028spc EAGLE RIVER INEERING SERVICES P.O. Box 773294 Eagle River, Alaska 99577 (907) 694-5195 roject No.: 01-027 ulated By: LB Date: 8/2/01 Legal: BLM Lot 30 T15N, R1W, Sec 8 Single Family 3 Bedroom Dwelling Bed Subsurface Wastewater Disposal Field TEST HOLE 1 Water use at 150 gallons per bedroom = Percolation rate = Wastewater application rate = Required absorption area = Bed width (W) = Gravel depth (D) = 450 gallons 3 minutes per inch 0.8 gallons per day per square foot 563 square feet 15 feet ~' feet Required length = Required absorption area / Bed width Required length = 563 / 1'5 Required length = ~ feet Total Excavation Depth = ~ feet 01-027Cal.xls 9:13 PM8/2/01 Municipality of Anchorage DEPARTMENT OF HEALTH & HUMAN SERVICES 825 "L' Street. Anchorage. Alaska 99502-0650 SOILS LOG -- PERCOLATION TEST PERFORMED FOR: 0"05'E?h qrld ~Tal;e ~ry'o]3~ DATE PERFORMED: LEGAL DESCRIPTION:-lo~' 3~,, ~.~f ~ /V t);rr, l,w.~d 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20- Township, Range. Section: Ttc~/, £ Iw,, s~c.9 SLOPE ' SITE I~LAN WAS GROUND WATER ENCOUNTERED? IF YES, AT WHAT DEPTH? Oepth to Water Al~er / Momtoring? /Z3 Date: 7-~'OI I i Reading Date Gross Net Del3th to Net PERCOLATION RATE --~ , {m,nutes/mcn~ PERC HOLE DIAMETER £' TEST RUN BETWEEN z~ / FT AND , FT PERFORMED BY: E./~. ~-..~. ~ ~ CERTIFY THAT THIS TEST WAS PERFORMED~N ACCORDANCE WITH ALL STATE AND MUNICIPAL GUIDELINES IN EFFECT ON THIS DATE DATE. ¢'7~ ...~,.~' -~:~ i? To: EA~LE ~IVEg. EN~INEEI~IN~ ~E~¥1~E~ - . : Legal description: T1fN F-,1W 5ECTION ~ LOT 30 Municipality of. Anchorage Development Services ~Department Building Safety Division On-Site Water and Wastewater prOgram 4700 South Bragaw St. P.O. Box 196650 Anchorage, AK 99519-6650 www.ci.anchorage.ak.us (907) 343-7904 . · ON-SlTESEWER/VVELL SUBMITTAL 'COMMENT: SHEET The attached paperwork has been reviewed and is being retUrned for the following reasons: Original signature or stamp missing on Calculation error in design. AdditiOnal soils information needed. water 'monitoring results inadequate. Discrepancy in information submitted. '-Topogi'aphic informatiOn missing or inadequate~ IncomPlete; miSsing. Incomplete; miSSing · · ' ' - - · ' Additi°~nal adequacy test infOrmation needed', i Water sample unacceptable.' , ~ ' MeasUred/PropoSed distances/dimenSions missing' ' LoCatiOns of all soils. Percolation and watermonit°fing tests not shown. '' prOposed system to° deep for soils information'submitted. Well Io~1 required.: ~ : . - ' ' : . '," .' Omission in narrative '-.. ' ' .- :. ' lnsufficient fill over tank or field, i' ''" ''' /,,~'~, :` :' !' ; · Other. 1i.) HOLDING Fol~ I~LM F-,/W E^sEMENT'TO DE ¥^c_~,Z. 'MAXiMuM WIDE PEAINFIELD NEED5 TO DE CHANGED TO 4- FEET Fi~.OM OF, IGINAL GI~ADE. . Name of reviewer: P^N Date: 7/31/0_1 PleaSe supply the necessary information and re-submit your request. LEA VE THIS FORM ATTACHED TO THE PAPERWORK QGRFtr ANCHORAGE AREA BOR"IGH D~partment of Environmental Oualit¥ 3330 C Street Anchorage, Alaska 99503 INSPECTION REPiORT ON-SITE SEWAGE DISPOSAL SYSTEM LOCATION il SEPTIC TANK: DISTANCE FROM WELl_ __ INSIDE LENGTH SEEPAGE NUMBFR OF PITS__ LINING MATERIAL --MANUFACTURER _ INSIDE WIDTF · DIAMETER _"'/~ CRIB SIZE: LIQUID DEPTH ·LIQUID CAPACITY BUILDING FOUNDATION / ~ , NEAREST LOT LINE NUMBEROF COMPARTMENTS /~00 GALLONS, · OR WIDTH /it", LENGT½-~'/'~., DEPTH DIAMETER-'I~"DEPTH /~-' . DISTANCE FROM: WEL~. TOTAL EFFECTIVE ABSORPTION AREA (WALL AREA) '~ (~ ~ _SQ. FT. ADDITIONAL ABSORPTION WELL: BUILDING NEAREST FOUNDATIDN __ LOT LINE ~ CESSPOOL OTHER SOURCES APPROVED DISAPPROVED NEAREST SEWER LINE REMARKS. . DEPTH DISTANCE FROM: SEPTIC/~)/~ ~ SEEPAGE TANK /~' /-~, SYSTEM,."31'//~.i DISTANCES: INSTALLED BY: PIPE MATERIAL: LOT SLOPE: REMARKS: DIAGRAM OF SYSTEM DATE UG,A.A.B, GREATERi ANCHORAGE' AREA BOROUGH SI~WAGE DISPOSAL SYSTEM -- APPLICATION AND PERMIT PERMIT NO, NAME OF APPLICANT LEGAL DESO.IPT,ON INSTALLATION OF: SEPTIC TANK SEEPAGE ,P~'r__ DRAIN FIELD , OTHER F,NANOED TH.OUG. ~'a COMPLETION DATE ANTICIPATED TO BE INSTALLED PHONE NOTI-'~ THIS PERMIT 15 NOT VALID WITHOUT SOIL TEST TANK S'ZE ///7~gT~PE. SEEPAGE AREA ~,zE T~P~ ~ r, ~ FOUNDATION TO SEPTIC TANK -- FOUNDATION TO SEEPAGE PIT SEPTIC TANK TO SEEPAGE Pit WALL ., DRAIN FIELD SEPTIC TANK __ , SEEPAGE PIT TO NEAREST LOT LINE. /r~O~ WELL 'TO SEPTIC TANK DRAIN FIELD_ WATER MAIN TO SEPTIC TANK DRAIN FIELD -*i DRAIN FIELD , ALSO CO~JSIDER AREA WELLS, , SEEPAGE PIT -- -, SEEPAGE Pit IDRA]N FIELD TO RIVER, LAKE, STREAM. CAST IRON INTO AND OUT OF SEP.TI ~~GAP EXCAVATION 5 FEET INTO UNDISTURBED SOIL. GRAVEL BACKFqL/ CONFORM TO BOROUG~-R~ULATION$ REGARDIcNG INS~ALLATfON, DATE ( ~ ~ ~ APPLICANT'S SlGNA URE AS-BUILT I hereby certify that I have mtrveyed the following described property'--_~tf-,.f:ft_-~:-~°-'~' ~.~ ....................... An~orage t~cordlng Precinct, Alaska, and thai the improvemenl~ situated thereon are within tho propart [inca al~d do not overl-sp or encroach oa the property lying adja.:cnt thereto, ti,at no impvovemen~ on prop- err7 lying adjacent thercto ~,aeroach on ~e ptmmlseg m que:tWn aBd thr. t there *~te no roadways, tfansmissWn lines or oth-r v[sibW easements on said proporty as indlcatod hereon. Dated r:t Eagle River, Alaska ti is ....~'. ~o y ROBERT C. JOllNSOf; ~ SCALE: F,".; s e vi' La ~d Survey )r No 1" ~ .~ ' Box 4ltl, Eagle River, Alaska Phone 694.2543 MEMORANDUM SUBJECT: 91-o10 (4/76) DATE RECEIVED INSPECTION APP(~INTMENTS qE TE ;PECTOR TIME DATE INSPECTOR /IUNICIPALITY OF ANCHORAGE DEPARTMEP T OF: HEALTH & ENVIRONMENTAL PROTECT~),~j,iCiPALiT¥, 825 L Street - Anchorage, Alaska 99501 ENVIRONMENTAL SANI'I'ATION DIVISION Telephone 264-4720 REQUEST FOR APPROV/~L OF INDIVIDUAL WATER AND DIRECTIONS: Comolete all parts on page 1. Incon]plete requests will not be processed. Please allow ten (10) days for processing. PHONE~ 1. PROPER ~OWNER MAiL NG ,~DDRESS ~ROPERTY RESIDENT (If different from a ~ PHONE 2. BUYE~ ! L PHONE MAILING ADDRESS 3. LENDING INSTITUTION ' ~' I PHONE I MAILING ADDRESS 4. R EALTO~_~R/AG E NT ~ I PHONE MAILING ADDRESS 5. LEGAL DESCRIPTION ~.,, ;TREET LOCATION 6. TYPE OF RESIDENCE NUMBER OF~BEDROOMS ~ One ~ Four ~ Other_ _ ~SINGLE FAMILY ~ Two ~ Five ~ MULTIPLE FAMILY ~ Three ~t~ Six 7. WAT~RR~UPPLY ¢~ INDtVIDUAL* *ATTACH WELL LOG. A well log is required for all wells drilled ~ COMMUNITY since June 1975, For wells drilled prior to that date, give well ~ PUBLIC UTI LITY depth (attach log if available.) ~ SEWAGE DISPOSAL SYSTEM ~ INDIVIDUAL/ON-SITE** ~;~ ~ YEAR ON-SITE SYSTEM WAS INSTALLED, ~ PUBLIC UTILITY NOTE: THE INSPECTION FEE MUST A~COMPANY EACH REQUEST BEFOFIE PROCESSING CAN BE INITIATED. 72-010 I Rev. 6/79} THIS SIDE FOR OFFICIAL USE ONLY 1. TYPE OF RESIDENCE NUMBER OF BEDROOMS [] SINGLE FAMILY [] ONE [] THREE [] FIVE [] OTHER [] MULTIPLE FAMILY E3 TWO [] FOUR [] SIX PERMIT NUMBER 2. WATER SUPPLY [] IND[VI DUAL DEPTH OF WELL [] COMMUNITY DATE DRILLED [] PUBLIC UTILITY Connection Verified LOG RECEIVED 3. SEWAGE DISPOSAL SYSTEM PERMIT NUMBER [] INDIVIDUAL/ON -SITE DATE INSTALLED []PUBLIC UTILITY Connection Verified iNSTALLER []Septic Tank or [] Holding Tank Size: 1(~)~)(~ If Tank is homemade SOILS RATING give dimensions: TYPE OF TANK MANUFACTURER~' TOTAL ABSORPTION AREA MATERIAL 4. DISTANCESwELLTO: Septic/Holding Tank Absorption Area Sewer Line Nearest Lot Line Absorption Area to nearest Lot Line 5. COMMENTS (~-/APPROV ED FOR ~--~ BEDROOMS [] CONDITIONAL APPROVAL (letter must ~e~mpany certificate) DISAPPBOVED ? ? 72-010 (Rev. 6/79)