HomeMy WebLinkAboutT15N R1W SEC 8 LT 36T15N R1W Sec 8 Lot 36 #051 -09143 MUNICIPALITY OF ANCHORAGE On-Site Water& Wastewater Program �� t PO Box 196650 4700 Elmore Road Anchorage,Alaska 99519-6650 Phone:(907)343-7904 Fax:(907)343-7997 http:Ilwww.muni.org/onsite ,, 1), 1,.11111, ni +hlH p0.PGE On-Site Wastewater Disposal System Permit Permit Number: OSP171287 Effective Date: 9/27/2017 Work Type: SepticTank Upgrade Expiration Date: 9/27/2018 Tax Code Number: 05109133000 9 /Z1 / i r k ,poor, Site Legal Address: T15N R1W SEC 8 LT 36 G:1357 Site Mailing Address: 20723 SCENIC DR, Chugiak Owner: FOSTER JAMES & BONNIE Lot Size in Sq Ft: 108900 Design Engineer: NORTH RIM ENGINEERING Total Bedrooms: 3 This permit is for the construction of: ❑ Disposal Field 0 Septic Tank ❑ Holding Tank 0 Privy ❑ Private Well 0 Water Storage All construction shall be in accordance with: 1. The attached approved design. 2. All requirements specified in Anchorage Municipal code Chapters 15.55 and 15.65 and the State of Alaska Wastewater Disposal Regulations (18AAC72)and Drinking Water Regulations (18AAC80) 3. The wastewater code requires inspections during the installation. The engineer shall notify the Development Services Department per AMC 15.65. Provide notification by calling (907) 343-7904 (24/7). 4. From October 15 to April 15, a subsurface soil absorption system under construction during freezing weather shall be either: a. Opened and Closed on the same day, or b. Covered, sealed, and heated to prevent freezing Received By: �� Date: /27 77 Issued By: , �' ' ����1t,s t� Date: -Aro/7 MUNICIPALITY OF &Mt • MPR• "-... Community Development Department " Phone: 907-343-7904 Development Services Division Fax: 907-343-7997 On-Site Water&Wastewater Program -. - - ON-SITE SEWER/WELL PERMIT APPLICATlc Rm., `',.\. SEP 26 ZL7 ) Parcel LD. 6'5/— 01/— 33 / Property owner(s) Po.3 FR Day ph0 - Mailing address 20 7 R3 _cerf J(L A /./..<,. ..2. -, Site address .3/4144 r Legal description (Sub'd., Block & Lot) 77577\( /R/M) di:77c a L 3 , Legal description (Township, Range & Section) Lot Size /Oe/ f2Sq. Ft. Number of Bedrooms 3 APPLICATION IS FOR: APPLICATION IS AN: TYPE OF DWELLING: (®all that apply) Absorption Field ❑ Initial ❑ Single Family (SF) (w/wo ADU) Septic Tank Upgrade Duplex (D) ❑ Holding Tank ❑ Renewal ❑ Multiple Dwellings ❑ Privy ❑ (SF and/or D) Private Well 0 Water Storage ❑ THIS APPLICATION INCLUDES A VARIANCE 1 WAIVER REQUEST FOR: Distance: I certify that the above information is correct. I further certify that this is in accordance with applicable Municipal Codes. (Signature of property owner uthorized agent) Permit/Rush Fees: .9,16' Waiver Fees: Date of Payment: Date of Payment: Receipt Number: OP/53 ) Receipt Number: Permit No. 05 P17-12g7 7 Waiver No. Permit App_9-1-12.doc .; te. �� ( at 41 r (few 6785 ,, 2T1- 11V ENGINEERING MEMO C;\' SEP G is 20it1\inl Steve Eng, PE, PH (907) 694-7028 c�r SteveEngPE@gmail.com of 6 g L g c^- Date: Date: 9/25/17 Number of Pages: To: MOA On-Site Services Subject: T15N R1W Section 8 Lot 36 Septic Tank Collapse- Emergency The subject septic tank has collapsed- a large hole is present with septage visible. The existing trench appears to be working OK. Please RUSH a permit so the tank can be replaced. The existing trench will remain. Please review as soon as possible. If there is need for additional information or clarification please give me a call. I Imnks-Stev \?THI ENGINEERING SteveEng.com T15N R1 W Section 8, Lot 36 SPECIFICATIONS & DESIGN GUIDELINES Wastewater System Sizing: This is an existing 3-bedroom home. Most of the neighboring lots are developed. The current septic tank has collapsed- the trench still functions. These lots are near an acre and are served by the private water wells . No adverse impacts are expected from tank replacement. The easements are depicted on the lot. The slope is indicated in the area of the septic system. Specification Requirements: All components and work must comply with the Municipality of Anchorage Specifications(AMC) & State of Alaska Drinking Water Regulations and Wastewater Regulations. • New 2- compartment, 1000 gallon septic tank. Watertight couplings on inlet & outlet. • 5' minimum between the tank and bed. 10' to property lines. • 4' of cover or insulation is required for tank; an equivalent of 1" insulation for 1' foot soil cover. Minimum of 2' soil with insulation. Tank& solid pipe must be set on well compacted, stable soil. • 4" diameter cleanouts with airtight caps are required 1' to 4' from foundation wall, prior to any 90 degree bend in 4 inch line, in each tank compartment, and two adjacent opposing cleanouts between the tank and the absorption field, not more than 10' from the tank positioned to provide cleanout access towards the tank and towards the absorption field. • All cleanouts must extend to at least ground level. • In solid pipe runs, ASTM D-3034 may be used in lieu of cast iron. • Insulation must be placed over any pipe installed under driveways or parking areas. • Approved pipe materials include cast iron, PVC ASTM D3034, PVC ASTM F789, ABS ASTM D2661, • Sewer Service Line is minimum 2% slope. • Septic Tank to be pumped every two years or when required. • Insulation board to be extruded direct burial polystyrene (Dow Styrofoam HI/equal) Of 44''' Ste,co 'rr. r ,1,2.s/I i.r^ DESIGN NOTES: 1. Existing Trench Remains In Place. 2. Sewer Service Line minimum 27 slope. 3. Replace Septic Tank/Decommission Old Tank Per UPC. Connect New Tank To Existing Trench. 4. Lots Served by Private Water Wells. 5. No Conflicts Within 200'. Mark 100' Well Radius. 6. Check Condition Of Sewer Service Line— Replace If Necessary. Ai ° .) 50' Patent ROW Reserve / V Flat Slope Flat Slope New 1000 Gallon Septic Tank w/DC❑'s Decommission Old Septic Tank PER UPC d 3 Bdrri 1111b'-ejt: Existing Trench u Flat Slope V) Flat Slope 8100 Well 3 I o ce Garage � � d D o Flat Slope U) Flat Slope 20'MEA Electric Ease nt T15N R1W SECTION 8 1' = 50' NORTHR1M .asm ENGINEERING •*• LOT 36 DESIGN PO Box 770724 LAYOUT Eog1e River, Alaska 99577 cE-44N WASTEWATER UPGRADE 907.694. 7028 (45 I REPLACE SEPTIC TANK 9/25/17 2�of 3 I Foundation Cleanout Tank Cleanouts Finade Opposing Cleanouts Between Septic Tank & Trench ute 4 Foot Cover or Equal 1 1000 Gallon Steel To Trench 'Anchorage Tank' Or Equal slid Pipe Match Elevations To DESIGN NOTESExisting FCD & Line 1. Use Existing Trench. 2. Septic Tank & Solid Pipe to be Placed on Compacted, Stable Soil, Free from Boulders. 3. Sewer Service Line is Minimum 2% Slope & 3' Cover. 4. Water-Tight Couplings. 5. See Specification Sheet. 6. All Work To Conform to Municipality of Anchorage (AMC) Requirements & Specifications. 7. Decommission Old Septic Tank Per UPC. 8. Check Condition Of Sewer Service Line. Replace And/Or Insulate If Necessary. NORTNRIM as4SEPTIC TANK PR❑FILE T15N R1W SECTI❑N 8 �, . ENGINEERING PO Box 770724 , E,, 1, L❑T 36 Eagle River, Alaska 99577 a t 907.694.7028 7 r r TANK REPLACEMENT °ati 9/25/17 ID"'" BY: SE 1- = 5 T'3 of 3 'Scale: I SE Fourth Floor %~est 825 L Street Anchorage, Alaska 99501 264-4720 .................... -I'~J-~'ECI'ION REPORT Obi-SITE SEWAGE DISPOSAL SYSTEM SF[:TIC 'i'AII K: LIQ~Jil) Dr' PTH I:i:.1:Jl LI31C, i'il ........... i:~;<,ilDL ;','II.)TII_ NUM. DER OF COMPARTME~ITS .~-- , __ t.lOUID CAPACITY.~..-~'~-- GALLONS. TILE :)fb',lrl [:IL".LD: TOTAL LENGTH Dlbl,..t:( [ I I{k~'.1 '~:~ LI ......... f:OL;;4i)/%TION_ -- .r;l AREET LOT Lit;E~_ OF LIHE ~ of Lines ......... t)IETAr4CC ~[l%'/EE~l LIHES .......... TREHCII %IIOTH~. 'TOTAL EFFECTIVE [~[FTII OF J ILT[R SEEPACE PIT: Log Crib WIDTH , LE:IGTH .., D[PTlt Crib Size: Rings CI,RML1 [ H .... L,[.I'I"II__~ [')IETAI'ICE FP, OM: WELL 'IO f;tL Ef FECTIVE A[:,,~C, RPTIO.~4 AREA (VIALL AREA) SQ. F'I Class: Depth: Well Distance To: Lot Line ]31dg: Se:.:er Line: Pipe Materials: ~ ii of Dcdro. ol::S: ~ Installer. i~cma L'ks: 1111 {Jill HUNICIPALi['I?Y OF ANCiIQNu\(zI'j ,1Lb and }.invironmen/al Pr, chi.on 825 ~, Streeh Anchorage, Alaska 99501 264-4720 %i1.'. P,..C~ iii: i E.,E/i:::'Fli:;~:Ti'iiJi~hi"i' HEI:::Ii..TH l::;d",iD ENV]£FbEd",ii'i[:iii",i~i'ii:lL. :iiTEC.'i"i'Ci",i f:ii i':'FiiC, i':.:l::i(]li!ii: i-:'L. Fli",i'i' i'il:':l:'r: [~ii!i!: ]:i",i:!i;'i"l::lL_L.i~!:L-.~ I::i-i' Ti"'iii~ F'Ei:~':i'iii]"f'i'[~:i:::":ii!; CIF'-i" :i: (;)i",[ :!:;iJiiiii..Zi'[!i)E.'i~ 'i"CI *iiiii{~ F' Oi..i . 0 i.,.i ii: i",i G :i.. E:['i"i*i[EF~: F:I C.i. Fii!ii;~i; ~Z Cli;;: :i::i: i",ki~i:::' FiiF'F'i:;b;l:,/~Ei].' F:'i...F~i",tT i'iFf'*; i!J~[~: -:' la C.(Z)i',i'i' :i: i",ii..iCd..i:iE; i'iFI Z i",i i"Ei'iiF:iii',h2. E!: F:lGi:;~:i!!!:i!i{i'i[ii:i",i'i" :i: :ii; ii;iiii~Z('::!Li ti; i:[~:[~:[Z.'. ;i; i::' FI i'il::l ii: F:l(]~i:;~:iii:iCi'iE:f'~;i' :[:E; i",iOT i':.:[Ei::"[' L-.i...iii'~:F~:iii~:i",i"i' :'r~l;:d..i i'il::l:T: i.:J~i!E i'~:iii~]:!Li]:F~[ii:D TO E:F,iL.Fli:;b:~E~ Ti-iiE Fliiii~:~:COi;iii:"T']Zl:)i",i ~;"*':~;'i'E:i'i I::iii",i[:.'.-'"~:]~[~: :.~;Oi. ii i'iFl~r~ iiii~[iiZ :~i;i,.i[ii;.ii'[ii:l:Yi 'i"(;Cl ¢ONSULTINe OEOLOelST SOILS LOG 0 2 4 6 16 18 Soil Type Water Level Remarks 2O Tetal Depth of Excavation Groundwater ~ Not Reached Depth, if Reached Classification Method ~) Visual ( ) Sieve Analysis () Material at Total Depth Bedrock ~ Not Reached Depth, if Reached ' ~-~-ry i Playe~, ~ons. ul~ng Geologist . i() f P L A t"l/" ~ ~'o.o' ~ MUNICIPALITY OF ANCHORAGE ~ DI~PART~ENT OF HEALTH & ENMIR( NMENTAL PROT CT ~,~ EQUEST FOR APPROVAL OF INDIVIDUALWATER AND 8EWER FACILITIES ~, PR~PERT~ OW~ E~ .... "- .... ~..,,c._,ln [,ul d, ys for process, ng ~PERTY RESID~ ~ d~ffere~t fro~ abo~e) ' ~ = 'J~HONI~ ' ' MAILING ADleR ES~ - MAI LIN G A~DR ESS .... 5, LEGAL DESCRIPTION ~__ 6. 'FYPE OF RESIDENCE ~ SINGLE FAMILY [] MULTIPLE FAMILY ~. WATER SUPPLy IND VIDUA L* COIV MUNITY PU ~LIC UTILITY 8. SEWAGE DISPOSAl. SYSTEM INDIVIDUAL/ON-SITE** PUBLIC UTI LITY NURSER OF BEDRODM8 E]' One [] Four C] Other [] Two [] Five ~ Three ~ ATTACH WELL LOG. A well log is required for all we, s a 'lied since JUne 1975. For wells drillea prior to that da[e, give wall dapth (attach_log if avaiJebJeJ mdlvldum/on-s~te, g[ve installation date c~'g If system is over two (2) years old an ade~'.a'cy'l:~st [s required · . by this Depar£ment. NOTE'. THE INSPECTION FEE MUST ACCOMPANY E ' ~ ' 72-010,3/78) ACH R EQUE8 T BE FOR E pR _OC~881ZA--'~B E-'~Ni 7E-'~--. t 'IME DATE ,~SPECTOR THIS SIDE FOR OFFICIAL USE ONLY INSPECTION APPOINTMENTS ~TIME )ATE ~-ATE RECEIVED TIME 3ATE INSPECTOR 31RECTIONS: · TYPE OF RESIDENCE I~) SINGLE FAMILY [] MULTIPLE FAM LY 2. WATER SUPPLY [] INC VlDUAL [] COMMUNITY [] PUBLIC UTI LITY Connection Verified 3. SEWAGE DISPOSAL SYSTEM [] NDIVIDUAL/ON -SITE [~]PUBLIC UT~ LITY Connection Verified _ E~]Septic Tank or [~ Holdin9 Tank Size:_ - ~f Tank is homemade dye oimens~ons: -YPE OF TANK -TOTAL ABSORPTION AREA 4, DISTANCES WELLTO: 5. COMMENTS NUMBER OF BEDROOMS [] ONE [] THREE [] ~IVE [] TWO [] FOUR [] SIX E~] OTHER PERMIT NUMBER DEPTH OF WELL ~-ATE DRILLED LOG RECEIVED P-~MIT NUMBER ~ATEINSTALLED ~HSTALLER SOILS qATING MANUFACTURER MATERIAL 3tion Area LIRe E]~i~APPROVED FOR ~-~ - BEDROOMS [] CONDiTiONAL APPROVAL (lei[er must accompany certificate) [] DISAPPROVED DATE LEGAL 3ESCRF:~' ON 12-010 IRev. 3/78) Thi~ well is producing ~' fg~llons o~ w~fer per hour. INVOICE CABIN FOIIMATION Municipality of Anchorage • • On-Site Water and Wastewater Program _t (907) 343-7904 3.11111 CERTIFICATE OF ON-SITE SYSTEMS APPROVAL Parcel I.D. 051-091-33 SU ``''•`ds:Ldt : 'Q^ O JUN 152018 1. GENERAL INFORMATION Complete legal description T15N R1W SEC 8 Lot.36 Location (site address) 20723 Scenic Drive Current Property owner(s) Foster Day phone 245-2285 Mailing address same Real Estate Agent John O'Hara Day phone 245-2285 2. TYPE OF DWELLING: ® Single Family (w/wo ADU) ❑ Duplex ❑ Multiple Dwellings (Single Family and/or Duplex) 3. NUMBER OF BEDROOMS: 3 4. TYPE OF WATER SUPPLY: TYPE OF WASTEWATER DISPOSAL: Individual Well ® Individual Individual Water Storage ❑ Holding Tank ❑ Community Class C Well ❑ Community ❑ Public Water System ❑ Public Sewer ❑ Received b • Date: 8//c/2v/8 COSA to be released to the engineer, unless otherwise requested by the engineer. COSA Fee $ Date: Date of Payment tqqr7 Date of Payment Receipt Number =3,3n Receipt Number COSA# 65C 52/3q4 Waiver# 5. STATEMENT OF INSPECTION BY ENGINEER As certified by my seal affixed hereto and as of the validation date shown below, I verify that my investigation, based on procedures outlined in the Certificate of On-Site Systems Approval Guidelines for this application, shows that the on-site water supply and/or wastewater disposal system is (are) safe, functional and adequate for the number of bedrooms and type of structure indicated herein. I further verify that based on the information obtained from the Municipality of Anchorage files and from my investigation and inspection, the on-site water supply and/or wastewater disposal system is(are) in compliance with all applicable Municipal and State codes, ordinances, and regulations;ih effect at the;tirpe.of installation. Name of Firm NorthRim Engineering Phone 694-7028 Address PO Box 770724,Eagle River Engineer's Printed Name Steve Eng _ Date 8/3/2018 • . 0 ,}i.• �a• Oo00. Q�Ot�l 6. DSD SIGNATURE x.6- —4 System #1 Approved for bedrooms. Ste !. Eng ; w System #2 Approved for bedrooms. L << �,��,0.5ot Disapproved. Conditional approval for bedrooms, with the following stipulations: j. Lir ON-SITE WATER AND r' WASTF►NATER Z • PROGRAM ;c Original Certificate Date: `" / F The Municipality of Anchorage Devlopment Services Division(DSD)Issues Certificates of On-Site Systems Approval(COSA)based only upon the representations given in paragraph 5 by an independent professional civil engineer registered in the State of Alaska.The Municipality of Anchorage is not responsible for errors or omissions in the professional engineer's work. 7. ATTACHMENTS: COSA Checklist X Nitrate Advisory Septic System Advisory Arsenic Advisory _ Well Flow Advisory Other COSA blue sheet_9-1-12.doc If more than 1 septic system is on the lot: COSA Checklist# of Structure served by this system Certificate of On-Site Systems Approval Checklist Legal Description: 775 5/i / 4A) 5 iL �� Parcel ID: 65/-0 Q/-33 A. WELL DATA P Well type If A, B, or C provide PWSID# Well Log (Y/N) Date completed i(/Z2/77Sanitary seal (Y/N) y Wires properly protected (Y/N) Total depth26 S ft. Cased to DVDft. Casing height groynd) s irl* FROM W LL LOG AT INSPECTION > nk� Date of test // 2-217 7 7/3�l P Static water level (J.t/I- ft. 25 ft. Well production Z g.p.m. ��' g.p.m. WATER SAMPLE RESULTS: Coliform O colonies/100 mL Nitrate J ‘Smg/L Arsenic 1' U ug/L Date of sample: 7/13/I 4f Collected by: /VA'4`7750°7- B. SEPTIC/HOLDING TANK S e_ / 'C-/DATA Tank Type/Material 25:151.- Date installed Z6/l 7 Tank size /000 gal. Number of Compartments Z- Cleanouts (Y/N) Foundation cleanout(Y/N) Depression over tank(Y/N) Al High water alarm (Y/N) // Date of pumping 7(12a d Pumper Son( 1147 Pc."--1/tv.s C. ABSORPTION FIELD DATA S 4c�� �o�ln, Date installed, //`17d Soil rating (g.p.d./ft2 or ft2/bdrm) I 5 System type T" t Length `7-� ft. Width S--c ft. Gravel below pipe z ft. Total depth 7 ft. Eff. absorption area S ftMonitoring tube Depression over field A/ Date of adequacy test ?/ c./tt Results (Pass/Fail) r For 3 bedrooms Fluid depth in absorption field before test /O in. Water added4S0 gal. New depth /5 in. Elapsed Time: 6 min. Final fluid depth /6 in. /i Absorption rate >= C--/-5-0 g.p.d. Any rejuvenation treatment (past 12 mo.) (Y/N &type) Uit/l� If yes, give date f D. LIFT STATION /V Jr Date installed Size in gallons Manhole/Access (Y/N) "Pump on" level at in. "Pump off' level at in. High water alarm level at in. Datum Cycles tested Meets alarm&circuit requirements? E. SEPARATION DISTANCES WELL ON LOT TO: Septic tank/lift station on lot /06 /74- On adjacent lots /'O "74-. Absorption Absorption field on lot /C) U =1" On adjacent lots / 0 0 (-F Public sewer main / 0 0 (-14. /Public sewer manhole/cleanout / C-147 't Sewer/septic service line z 5 Holding tank / 0 d t Animal containment areas <-5-'0 7' Manure/animal excrete storage areas /G Q 4' SEPTIC/HOLDING TANK ON LOT TO: Building foundation /Q 4- Property line l0 74" Absorption field (-1- Water 1-Water main / D /I- Water service line /6 ("f" Surface water /CJQ r-b Wells on adjacent lots /aO r'Y ABSORPTION FIELD ON LOT TO: Property line /0 1¢" Building foundation /c7 /°` Water main /o !f Water Service line /0 '' Surface water ( GG r4-- Driveway, parking/vehicle storage lv /1— i` Curtain drain •(//J Wells on adjacent lots (0 d F F. COMMENTS G. ENGINEER'S CERTIFICATION I certify that I have determined through field inspections and ,f. review of Municipal records that the above systems are in h.>•'. 4;! °y'S'a0, conformance with MOA COSA guidelines in effect on this date. 'R !?'r . fr of Engineer's Printe Na e �rF w" ‘ yo. . !-; ,.5e_cl to, ,Q co •. Steven W.Eng ; Date Cf g /GJ rdt�,�•. E � l��% COSA yellow sheet_2-6-15.doc • 4 1 \ t \ ! ti. spy • X i e J ' + t • - 7 y t, 4 hd I' 4 i it I ASBUILT SEWARD & ASSOCIATES LAND SURVEYING 694-0829 I HEREBY CERTIFY THAT I HAVE SURVEYED THE SCALE' ,i FOLLOWING DESCRIBED PROPERTY= ,�— ' '$/t) 4-7_ OF 4z�%R AND THAT NO ENCROACHMENTS EXIST EXCEPT AS GATE=� INDICATED. IT IS THE RESPONSIBILITY OF THE OWNER TO DETERMINE THE EXISTENCE OF ANY GRID •..e. EASEMENTS, COVENANTS, OR RESTRICTIONS st/cui WHICH 00 NOT APPEAR ON THE RECORDED SUBDI— �' VISION PLAT. UNDER NO CIRCUMSTANCES SHOULD F8' t' eve�SMnrk $ - .:• - ANY DATA HEREON BE USED FOR CONSTRUCTION �,`s"Z� ,�� 47. OF FENCE LINES, OR FOR ESTABLISHING BOUND- "" - �' �' # ARY LINES. D2AWN' � x' :