HomeMy WebLinkAboutSKYHILLS PH 2 BLK 3 LT 105kyhills Block 3 Lot 10 #011-122-36 Municipality of Anchorage Page I of 3 DEPARTMENT OF HEALTH AND HUMAN SERVICES ENVIRONMENTAL SERVICES DIVISION P.O. Box 196650 o Anchorage, Alaska 99519-6650 · Telephone: 343-4744 On-Site Wastewater Disposal System and/or Well Inspection Report Permit Number: SW990090 PIDNumber: 011-122-36 Name: Wastewater System: [] New [] Upgrade / Crown Pointe. Inc. Address: P.O. BOX 112313 Anch., AK 99511 ABSORPTION FIELD -- [ No. of Bedrooms: Phone: 345-6277 Six (6) ~ Deep Trench [3 Shaltow Trench ~Bed ~Mound ~Other To a Dep h from original grade: LEGAL DESCRIPTION Boil Rating; . 6 GPD/Sq. Ft 1 3. 5' ~ S~ i ~ion: Depth to pipe bottom f(om ori iflalgrade: Gravel depth beneath pipe Lot: 1 0 Block: 3 Sky H~[s, it2 3.5~ Ft__ 1 0 ' Ft. Township: I Range: I Section: Fill added above original grade: Gravel leng,h: I 0 Ft. 7 8 I Ft~ WELL: ~ New ~ Upgrade Gravelwidth: 3 ' Numberoflines: 0istancebe~w~nEnes: ~a%ilication (Private, A.B.C): Total Depth: Cased To: Total absorption area: Pipe material: City Water Ft. Ft. 1,248 SO. Ft. ASTM D3034 PVC ~iller; Date Drilled: StaticWater Level: Installer: Date installed: Ft LH Construction .~/21 /99 ~eid: GPM PumpSetat: Ft. ~CasingHeightAboveGround:Ft TANK SEPARATION DISTANCES s Septic B Holding B S.T.E,P. TO Septic Abso~tion Lift Holding )ublic/Private :Manufacturer: CapaciW in gallons: From Tank Fietd Station Tank SewerLines Anchoraq¢ T&nk 2,000 Number of Compa~ments: Weft Cit~ Watez Material:Steel Two ( 2 ) Sudace >100 >100 H/A N/A N/A LIFT STATION - ~/A LOt > 5 ' > 10 ' N/A N/A N/A Size in gallons: Manufacturen Line ~ Electri~l Insp~tions peflormed by: Cu~ain None 4DEed on Lo' PumpMake&M~el Drain Remarks: BENCH MARK Location and Description: Front Porch Deck ENGINEER'S SEAL Inspections performed by: MEA __ Dates: lsL5/21/99 ,¢j;~&~t; '"?~, .~.oo%oo( Depadment of Health and Human Se~ices approval ,'¢ ~,~4 ,, ,,~¢~, 72-013 (Rev, 9/91} MOA 25 Municipality of Anchorage Page 2 of 3 DEPARTMENT OF HEALTH AND HUMAN SERVICES ENVIRONMENTAL SERVICES DIVISION P,O. Box 196650 Anchorage, AK 99519-6650 343-4744 On-Site Wastewater Disposal System or Well Inspection Report Permit Number SW990090 PID No. 011-122-36 37.3 29.0 Alternate 39.8 C4 Site M1 C5 / / / / / / SiX Bedroom Home / - / / / !! .~ / ! ~ ~ ~- c: ~ mO.:' / HEAVENLY S - Septic Vent C Cleanout M - Monitor Tube T - Test Hole PLAN AS-BUILT SCALE 1" = 40' Municipality of Anchorage Page 3 of 3 DEPARTMENT OF HEALTH AND HUMAN SERVICES ENVIRONMENTAL SERVICES DIVISION P.O. Box 196650 Anchorage, AK 99519-6650 343-4744 On-Site Wastewater Disposal System or Well Inspection Report Permit Number SW990090 PID No. 011-122-36 96.15 2,000 Gallon Septic Tank 8. 88.55 92.2 ~ Geotextile Drainfield ~78.5 Fabric I '~,9. Rock 72.5 78' ~ ROF]LE AS-IBUIL'r HORIZONTAL SCALP' 1" = 10' NO VERTICAL SCALE MUNICIPALITY OF ANCHORAGE Department of Health and Human Services On-Site Services Program 825 L Street, Room 502 P.O. Box 196650, Anchorage, AK 99519-6650 (907) 343-4744 ON-SITE WASTEWATER DISPOSAL SYSTEM PERMIT Initial Date Issued: May 10, 1999 Expiration Date: May 09, 2900 Permit Number: SW990090 Legal Description: SkyHills Ph 2 BIk 3 Lot 10 Design Engineer: 0014 Anderson Engineering Owner Name: Crown Pointe, Inc. Owner Address: PO box 112313 Anchorage, , AK 9951%2313 Parcel ID: 011-122-36 Site Address: unknown Lot Size: 41064 SQ. FT. Total Bedroomsi.~/~,,).¢~ Permit Bedrooms:/4~ This permit is for the construction of: E/~ Disposal Field L~ Septic'f'ank [] Holding Tank ~ Privy [] Private Well [] Water Storage All construction must be in accordance with: 1. The attached approved design. 2. All requirements specified in Anchorage Municipal Code Chapters 15.55 and 15.65 and the State of Alaska Wastewater Disposal P, egulations ( 18AAC72 ) and Drinking Water Regulations ( 18AAC80 ). 3. The engineer must notify DHHS at least 2 Irours prior to each inspection. Provide notification by calling (907) 343-4'744 ( 24 hours ). ( Not required for a Water Supply Permit only ). 4. From October 15 to April 15, a subsurface soil absorption system under construction during freezing weather must be either: A. Open and closed on the same day. B. Covered, sealed, and heated to prevent freezing. MEMORANDUM DATE: May 4, 4099 t ECEI V£'D TO: Onsite Services Engineer MAy 4 1999 FROM: Mike Anderson, P.E. ?Y~' Oept' He~l,~"~ ot AnChOr SUBJECT: Lot 10, Block 3, Sky Hills Subdivision "~ervicea Septic System Permit The owner of Lot 10, Block 3, Sky Hills Subdivision has decided to construct a six bedroom home on the lot. Our previous application for an onsite septic system construction permit was for a four bedroom home. We have therefore modified the pertinent pages of the design to reflect the six bedroom home and have changed the permit application to reflect six bedrooms. Please switch the attached pages with their counterparts previously submitted and issue the permit for a six bedroom home. Thank you for your assistance with this matter. April 26, lg99 Municipality of Anchorage Department of Health and Human Services 825 "L" Street Anchorage, AK 99502-0650 Subject: Lot 10, Block 3, Sky Hills Subdivision Septic System Design Permit Application Impacts to Adjacent Properties Dear Onsite Services Engineer: The owner' of Lot 10, Block 3, Sky Hills Subdivision intends to construct a six bedroom home on the Iot. We are therefore requesting a permit to construct a septic system on the lot to serve the house. The subdivision is served by the Municipal water system so a well permit is unnecessary. The attached site plan and backup documentation describe the proposed system and show the location of the new system. Tile testholes placed on the property revealed poorly graded silty sands which percolated at rates between 17 and 18 minutes per inch. Groundwater was not encountered during the excavation nor was any noted during the monitoring period. We have therefore designed a deep absorption trench with 10' of gravel beneath the distribution pipe. The trench will be '75' long with a total depth of 13'. Tl~e ground surface on the lot slopes to the east from the proposed house location at a rate approximating 5%. This is the area of placement for the absorption trench. The trench will be constructed perpendicular to the slope. No conflicts exist with other lots in the area where septic systems have been or will be constructed. All segments of the new system will be constructed a minimum of 10' from the water service line and 10' from all lot lines. If the system is constructed in accordance with our design the following statements apply: The system, if constructed as designed, will have no adverse impact on the wells in the area or those to be constructed in tile future. The subdivision is currently served by a community water system. 2. The system, if constructed as designed, will have no adverse impact on existing septic systems in the area or those to be constructed in the future. Lot 10, Block 3, Sky Hills Subdivision April 26, 1999 Page Two The system, if constructed as designed, will have no adverse impact on reserved space, either surface or subsurface, on any lots located in the area. The system, if constructed as designed, will have no adverse impact on drainage patterns in the area. The current drainage pattern will be maintained. Sincerely, Michael E. Anderson, P.E. Attachments SkyHills Su bdi v isior~ '"-^~ H/~BUBD. 2C lO Vacant I~ACT A Vacant Vacant Vacant 9 EVANSON C~URT KINCNO ACRES IH-lB ~o n~4o ~41 Vacant Lnt S PROjEcT Vacant Vacant TH~8 2 13 AREA MAP SCALE 1" = 200' UNSUBOJV][~D N 06*34°25"£ 206.25' 10' T. & E. ESNIT- _ .... / / I I N 07°12'46"F-. 75.25' HEAVENLY 'CIRCLE- LOT 10, BLOCK 3, SKY HILLS DESIGN FACTORS: Six Bedroom Home Perc. Rate: 18 Min./Inch Application Rate: .§ GPD/SF SYSTEM RFQUIREMENTS: Deep Trench System 2,000 Gal. Septic Tank 10' Drainfield Flock 6 Bedrooms X 150 GPD / .6 GPD/SF = 1,500 SF of Absorption Area 1,500 SF/20 SF/ LF of Trench = 75 LF Trench Length Therefore: Construct a Deep Absorption Trench System With One Lateral 75' in Length with 10' of Drainfield Rock Beneath the I..ateral. Distribution Pipe in 'French Placed at 3' Below the Original Ground Surface. Natural Backfill Geotextile Fabric 4" Perforated PVC (Slots Down) Drainfield Rock NOTE: TYPICAL DEEP TRENCH SECTION (NO SCALE) Grade Area Over Trench to Drain Away. Minimum 3' of Cover over Septic System. Maintain 10' Separation From Lot Line. Municipality of Anchorage. DEPARTMENT OF HEALTH & HUMAN SERVICES 825 "L" Street, Anchorage, Alaska 99502-0650 SOILS LOG -- PERCOLATION 'rEST PERFORMED FOR: L H Construction, t 7 8 9- 10- 11 13- 14- 15- 16- 19- 20- COMMENTS Pert cavity was Inc. DATE PERFORMED: Township, Range, Section; SLOPE SITE PLAN WAS GROUND WATER ENCOUNTERED? Monitoring? s L IF YES, AT WHAT Y O DEPTH? p Reading Date Gross Net Depth to Net Time Time Water Drop PERCOLATION RATE / ~ _ {m~nutes/mch) PERC HOLE DIAMETER p~esoa~ed ~ior ~o < ,,±ehael E, Anderson ~/Z,~ f~ IN PEREORMEOB~ , ,M,~ ~ g/~-~Y THA~ THIS TEST WAS PERFORMED ACCORDANCE WITH ALL STATE AND MUNICIPAL GUIDELINES iN EFFECT ON THIS DATE. ()ATE: . Municipality of Anchorage. DEPARTMENT OF'HEALTH & HUMAN SERVICES 825 %." Street, Anchorage, Alaska 99502-0650 SOILS LOG -- PERCOLATION TEST PERFORMED FOR: L H Construction DATE PERFOt LEGAL DESCRIPTION: LT 1~2/BLK~ Sky 1 2 3- 4- 5- 6- 7- 8- lO- 11 F1L 13- 14- 15- 16- 17- 19- 20- COMMENTS P e r c Hills Subdivision SLOPE Il. SITE PLAN WAS GROUND WATER ENCOUNTERED? DEPTH? .I Depth Io Water After Reading Date Gross Net Depth to Net Time Time Water Drop PERCOLATION RATE I-I TEST RUN BETWEEN '~' ~'~ cavity was presoaked (minutes/tach) PERc HOLE DIAMETER __ FT AND ~) FT Michael E Anderson ACCORDANCE WITH ALL STATE AND MUNICIPAL GUIDELINES iN EFFECT ON THIS DATE. DATE: ON-SITE WASTEWATER DISPOSAL SYSTEM CONSTRUCTION AND MATERIAL SPECIFICATIONS SUBJECT: LOT 10, BLOCK 3, SKY HILLS GENERAL: 1. The scope of this project includes the procurement and placement of a new 2,000 gallo¢ septic tank. It also includes the construction of a new 75' long x wide x 10' effective depth absorption trench at the location shown on the attached Site Plan. The total depth of the trench will be 13' below existing ground. Mounding over the trench may be required to provide a minimum of 3' of protective cover. 2. Construction shall be in accordance with the approved site plan, design drawings, Municipal Permit with any special provisions or conditions, and all applicable State and Municipal Wastewater Disposal Regulations. The Contractor shall be responsible for obtaining all underground utility locates and for the layout of the septic system and verification of the location of all lot lines. 4. Unless specifically agreed otherwise, the contractor shall be responsible for final grading areas subsequently depressed from soil settling. Property owner shall be responsible for revegetation of affected areas unless specifically agreed otherwise. 5. Contractors installing wastewater disposal systems must be certified by the Municipal Depadment of Health and Human Services for system installations. Owners installing their own systems must receive prior approval from D.H.H.S. before beginning system installation. SEPTIC TAN~( INSTALLATION 1. The 2,000 gallon septic tank must be procured from an approved source and installed at the location shown on the plans. 2. A septic tank is to be constructed by a certified septic tank manufacturer. Construction shall include two 4' cleanouts for pumping access. 3. The septic tank shall be sufficiently bedded to prevent settling or shifting of the tank. All standpipes on the septic tank shall extend a minimum of 12 inches above final grade. Tanks installed without 4' of cover shall have a minimum of 2 of d'rect burial insulation. A foundation cleanout shall be installed one to four feet from the building foundation. Two cleanouts are required between the tank and the drainfield. Lot 10, Block 3, Sky Hills SubdiviSion April 26, 1999 Page 3 of 3 5. A permeable geotextile fabric (Typar, Mirafi or equal) must be installed between the final drain rock layer and the native soil layer. 6. All drain rock shall be .5 to 2.5 in diameter with less than 3% passing the #200 sieve. INSPECTIONS: A minimum of two inspections are required by Municipal Ordinance. These inspections must be conducted under the supervision of a professional engineer registered in the State of Alaska. The first inspection must be conducted after the excavation of trenches, beds or pits and before the installation ef any gravel. A septic tank may be set in place, but may not be backfilled. The second inspection must be conducted after the placement of the geotextile fabric, gravel, distribution p png, standp pes, cleanouts and insulation. No backf should be in place at the time of inspection. Contractor shall provide a copy of all fie d survey layout and construction notes for use in prepar ng the certified as-built of the completed system. · 1[.ot 10, Block 3, Sky Hills Subdivi§t~l~ April 26, 1999 Page 2 of 3 7. Final grading over the tank shall be such that a positive slope exists away from the septic tank. DRAINFIELD CONSTRUCTION: 1. The drainfield shall be constructed to the dimensions shown on the design. The bottom of the trench shall be within 2" of level. 2. Distribution piping must be placed level with perforations down atop a level bed of drainfield rock. Rock should then be placed over the pipe to provide a minimum of 2" of cover. 3. A silt barrier or geotextile fabric must be placed between the drainfield rock and the natural soil backfill. 4. Monitor tubes must be 4" in diameter and installed at the locations shown on the design. The portion below ground must be perforated. 5. Contractor shall verify the septic tank and drainfield are a minimum 100' away from any private water wells in the area, 150' from a Class "C" Well or 200' from any community well. 6. Direct bury insulation must be placed over the distribution system if less than 3' of backfill depth is available. Finish grade over the trench must be mounded to prevent settlement or depressions. 7. Grade area surrounding the absorption trenches to drain away. 8. A minimum 2' of accepting soil is required below the drainfield rock for a 5' wide trench. Contractor shall verify this condition prior to placement of the rock. All pockets of unacceptable materials must be removed and replaced. MATERIAL SPECIFICATIONS: 1. Septic tank.,; must be constructed by a Municipally approved septic tank manufacturer. 2. The following pipe materials are approved for use in septic system installations in the Municipality of Anchorage: Cast Iron (perforated and solid), ASTM D3034 or P.V.C. (perforated and solid), ASTM F810 or H.D.P.E. (perforated, but not solid) and AS'¥M D2662 or A.B.S. (perforated and solid). 3. Insulation shall be at least 2" thick extruded direct burial polystyrene (Dow Chemical Co. Styrofoam HI or equal). 4. Septic tank inlets and outlets shall be fitted with watertight couplings (Caulder, Fernco, or equal). Parcel 1.D. 011-122-36 Certificate of On -Site Systems Approval Expiration Date: q_3 cq —2cg ? c) 1. GENERAL INFORMATION Complete legal description SKYH ILLS PH 2 BLK 3 LT 10 Location (site address) 8130 Heavenly Cir Current property owners), Fleckenstein Day phone 830-2580 Mailing address � Real estate agent V Day phone /r, nV Hu 2. TYPE OF DWELLING: a- JUL 6 20119 ❑ Single Family (w/wo ADU) R: Fj Duplex cuAj ❑ Multiple Dwellings (Single Family and/or Duplex) ZZ 01 6 g L 9 51\ 3...NUMBER OF BEDROOMS: 6 4. TYPE OF WATER SUPPLY: TYPE OF WASTEWATER DISPOSAL: Private Well El Private Septic Z Water Storage El Holding Tank El Community Well El Community 1771 Public Water System RX Public Sewer El Waiver request for: Distance: Received by: Date: COSA to be released to the engineer, unless otherwise requested by the engineer. 5. STATEMENT OF INSPECTION BY ENGINEER As certified by my seal affixed hereto and as of the validation date shown below, I verify that my investigation, based on procedures outlined in the Certificate of On -Site Systems Approval Guidelines for this application, shows that the on-site water supply and/or wastewater disposal system is (are) safe, functional and adequate for the number of bedrooms and type of structure indicated herein. I further verify that based on the information obtained from the Municipality of Anchorage files and from my investigation and inspection, the on-site water supply and/or wastewater disposal system is (are) in compliance with all applicable Municipal and State codes, ordinances, and regulations in effect at the time of installation. I acknowledge that On -Site staff may visit the site to verify the information submitted. Name of Firm NorthRim Eng. Phone 694-7028 Address PO Box 770724, Eagle River Engineer's Printed Name Steve Eng Date 7/17/19 00 6. DSD SIGNATURE _`�°..r- k °z�'i�� M k.no en e System #1 Approved for bedrooms System #2 Approved for bedrooms `,`y ; Steven w. "n9 �L V" J'�.�= PE 256 Disapproved �~- Conditional approval for bedrooms, with the following stipulation.,� 4lt((f((y�( `�V� Oy OFq l_glTE_ WATER AND .2.3 B� Original Certificate Date:_ The Municipality of Anchorage Development Services Division (DSD) issues Certificates of On -Site Systems Approval (COSA) based only upon the representations given in paragraph 5 by an independent professional civil engineer registered in the State of Alaska. The Municipality of Anchorage is not responsible for errors or omissions in the professional engineer's work. 7. ATTACHMENTS: COSA Checklist Septic System Advisory Well Flow Advisory COSA Checklist blue sheet X Nitrate Advispryi Arsenic Advisory Other Legal Description: SKYHILLS PH 2 BLK 3 LT 10 If more than 1 septic system on lot: COSA Checklist # of A. WELL DATA ❑ Well log is filed with Onsite (or attached) Date drilled Total depth ft Cased to ft ❑ Sanitary seal is functioning correctly ❑ Wires are properly protected Casing height (above ground) in. Date of flow test for COSA Static water level at beginning of test ft. Comments B. TANK DATA Age of tank(s) 5'2199 years Tank type/material Steel Measured operating fluid level in septic tank 46 ❑ Standpipes/foundation cleanout per record drawing Date of pumping 4/30/19 D. ABSORPTION FIELD DATA 5/21/99 Which system tested (date installed) S21 A99 ❑ ALL standpipes .present per record -drawing Total measured depth from grade. 12.5 ft (max) Measured depth to pipe invert from grade 3.5 ft (min) ❑ N/A _ pressufized field ❑ Monitor tubes go to bottom of effective. If not, state depth into effective 9' ❑ Code -required soil cover over field ❑ System presoaked (Required if vacant for greater than 30 days prior to date of test) Gallons introduced gallons Comments/Deficiencies: COSA Checklist yellow sheet Parcel ID: 011-122-36 Structure served by this system Well production at time of test gpm Water storage tank volume gallons Well disinfected for coliform test? ❑ Yes ❑ No ❑ Coliform bacteria is Negative Nitrate mg/L ❑ Nitrate less than MRL (ND) Arsenic ug/L ❑ Arsenic less than MRL (ND) Collected by _ Date of Sample C. LIFT STATION ❑ Required maintenance completed Age of lift station years Lift station material Comments: Adequacy test date 7/16119 Results R7 Pass For 6 bedrooms Fluid depth prior to test 18 in Water added 900 gal New depth 30 in Elapsed time 60 min Final fluid depth 20 in Absorption rate aee gpd Any rejuvenation treatment (past 12 months) no If yes, enter date E. SEPARATION DISTANCES From Private Well on Lot to: (Please enter distances if less than required or if community well) Septic Tank/Lift Station on Lot > 100' ✓❑ Yes Community Sewer Manhole/Cleanout > 100' ❑ Yes if No ft ❑ Yes if No Neighboring Tank > 100' ❑ Yes if No ft Private Sewer/Septic Line > 25' ❑ Yes if No Absorption Field on Lot > 100' ❑ Yes if No ft Holding Tank > 100' ❑ Yes if No Neighboring Absorption Fields > 100' Yes if No Animal Containment > 50' ❑ Yes if No ❑ Yes if No ft if No ft F. ENGINEER'S COMMENTS Manure/Animal Excreta Storage > 100' Community Sewer Main > 75' ❑ Yes if No ft ❑ Yes if No From Septic/Holding Tank on Lot to: (Please enter distances if less than required) Building Foundations > 10' ✓❑ Yes if No ft Surface Water > 100' ft ft ft ft ft 0 Yes if No ft Property Line > 5' ✓❑ Yes if No ft Wells on Adjacent Lots: Absorption Field > 5' ❑✓ Yes if No ft Private Wells > 100' ❑✓ Yes if No _ Water Main > 10' ✓❑ Yes if No ft Community Wells > 200' ❑✓ Yes if No Water Service Line > 10' ✓❑ Yes if No ft If septic tank is under driveway comment below From Absorption Field on Lot to: (Please enter distances if less than required) Building Foundation > 10'✓❑ Yes if No ft If absorption field is under driveway comment below Property Line > 10' ❑✓ Yes if No ft Wells on Adjacent Lots: Water Main > 10'✓❑ Yes if No ft Private Wells > 100' ❑✓ Yes if No Water Service Line > 10' ❑✓ Yes if No ft Community Wells > 200' ✓❑ Yes if No Surface Water> 100'✓❑ Yes if No ft F. ENGINEER'S COMMENTS G. ENGINEER'S CERTIFICATION - t' 1 certify that / have determined through field inspections and review of Municipal records that the above systems are in conformance with MOA COSA guidelines in effect on this date. \ �a .l COSA Checklist yellow sheet ft ft ft ft C", (AAS -M1 CM4 =Tp -r n0a amnia ,E,aAoc ME RAmm sszn+ac RUR OLUMOG SMACK �I UNDER NO CIRCUMSTANCES MOULD AN AS -BUILT BE USED FOR CONSTRUCTION OR FOR ESTABLISHING BOUNDARY OR FENCE LINES. THE SURVEYOR TAKES RESPONSIBILITY FOR THE INITIAL TRANSACTION ONLY AND ASSUMES FINANCIAL LIABILITY ONLY FOR THE COST OF THE SURVEY, LISTED DISTANCES PREVAIL OVER SCALING. REPRODUCTION MAY CAUSE ERRORS IN SCALE. Lor SURVEY TYPE SYMBOLS FOUtdDA'nON !?A110H t,S-EJ�.,T SET REBAR DRAINAGE tTr1AL slmlcruRe AS MMT a FOUND REBAR AS,oHALT Q PLOT PLAN ... !S-EEIII.T ...CAT S,R%EY .. TCPOMAPHY 'e--9--$ WOOD FENCE '.•.: CONCRETE As -BUILT . No st r T bs- xo 00 ASSUMED ELEV. I. x y{- METAL FENCE ® MOOD DECK PLOT PLANS & LOT SURVEYS NC3Ti' IT IS THE RESPONSIBIUTY OF THE BUILDER OR OWNER, PRIOR TO CONSTRUCTION, TO VERIFY PROPOSED BUILDING GRADE RELATIVE TO FINISHED GRADE AND UTILITY CONNECTIONS AND TO DETERMINE THE EXISTENCE OF ANY EASEMENTS, COVENANTS OR RESTRICTIONS WHICH 00 NOT APPEAR ON THE RECORDED SUBDIVISION PLAT. SURVEY CERTIFICA11ON PLOT PLAN OF �4 I h.I ty eau? that t nave Pn y . v.�o 1 ��< ,•. ;;'' :. C�_ j�� ma idt d,,- a,d d...Ya�.d harm,, and mot I \ \Y hew frond « .st.af.hed m of ub [at m " a whin a the pan and 1. m. best o/my �' `•��.µ{� .f.dg. and ablttlea w CkVk Ilms haus ban me..urod tnf. and eorroet L FOUNDATION AS -BUILT ���+/1y 'y r ' . ••.•er[....: L R.baf L � .. h-.br a.mfy tae t .. , - fqw a•'lartnw m Ar-S+tt nr m. � toa,( tka. a, tfil. iet a+d nwt a( th. • ,•••. .. ,:r::.JJ r' .... .. d"wnkne W4 efioAn ht4matku m .f.os, haaoni" • ROBE�i.TE. An. and no afcrwile" w nlst h"W FINAL STRUCTURE AS -BUILT �� �� "'✓ ;'•��AAI C Acb.1 E Xhnt &., ,,r.ny o tfPy ty.i I f' "."• Jt ^� .t.e_ k bt void hwt pCr ^e ,`.... ..•'`• tj �" mm.,.abn. awe h,anfatsm .. r.a., ,,..v, ���1�°� pro �a�a��•�• en tn.. ard no vvrarinects .ad, ul.pe i'� �e Sion�a� .�,'�. .no.., ou+rr.ioc �4r.te�d.� ONLY THOSE IMPROVEMENTS ABOVE GROUND AND VISIBLE WILL BE SHOWN. FENCES, WELLS, SEPTIC CLEANOUTS, SIDEWALKS, DRIVEWAYS, ETC., ARE SHOWN IN 71HEIR APPROXIMATE LOCATION, ONLY, SNOW MAY PREVENT SOME IMPROVEMENTS FROM BEING SEEN ANO LOCATED. ALL DISTANCES ARE RECORD UNLESS OTHERWISE NOTED. Prepared by Robert E. Johns, Jr. & Assoc. Professional Land Surveyors 1700 Brink Drive. ANCHORAGE, ALASKA 99504 q _ 50' Rac. Lot S.F. 04/18/14 Drawn by. REJ 04/18/14 Grid: 2222 Lot 10 Block 3 SKYHILLS PH 2 File No. W.O. 14-125 071, 4 630'00 �`► 1 =29. g C. .sLU ar r � O Q t Cj f t, r o V_ `t EXISTING Za. HOUSE S. I CV F z UjN o w m o `r' If t 8 237,32. '27'40- 2?40 E N m I u T7 J 30' UNDER NO CIRCUMSTANCES MOULD AN AS -BUILT BE USED FOR CONSTRUCTION OR FOR ESTABLISHING BOUNDARY OR FENCE LINES. THE SURVEYOR TAKES RESPONSIBILITY FOR THE INITIAL TRANSACTION ONLY AND ASSUMES FINANCIAL LIABILITY ONLY FOR THE COST OF THE SURVEY, LISTED DISTANCES PREVAIL OVER SCALING. REPRODUCTION MAY CAUSE ERRORS IN SCALE. Lor SURVEY TYPE SYMBOLS FOUtdDA'nON !?A110H t,S-EJ�.,T SET REBAR DRAINAGE tTr1AL slmlcruRe AS MMT a FOUND REBAR AS,oHALT Q PLOT PLAN ... !S-EEIII.T ...CAT S,R%EY .. TCPOMAPHY 'e--9--$ WOOD FENCE '.•.: CONCRETE As -BUILT . No st r T bs- xo 00 ASSUMED ELEV. I. x y{- METAL FENCE ® MOOD DECK PLOT PLANS & LOT SURVEYS NC3Ti' IT IS THE RESPONSIBIUTY OF THE BUILDER OR OWNER, PRIOR TO CONSTRUCTION, TO VERIFY PROPOSED BUILDING GRADE RELATIVE TO FINISHED GRADE AND UTILITY CONNECTIONS AND TO DETERMINE THE EXISTENCE OF ANY EASEMENTS, COVENANTS OR RESTRICTIONS WHICH 00 NOT APPEAR ON THE RECORDED SUBDIVISION PLAT. SURVEY CERTIFICA11ON PLOT PLAN OF �4 I h.I ty eau? that t nave Pn y . v.�o 1 ��< ,•. ;;'' :. C�_ j�� ma idt d,,- a,d d...Ya�.d harm,, and mot I \ \Y hew frond « .st.af.hed m of ub [at m " a whin a the pan and 1. m. best o/my �' `•��.µ{� .f.dg. and ablttlea w CkVk Ilms haus ban me..urod tnf. and eorroet L FOUNDATION AS -BUILT ���+/1y 'y r ' . ••.•er[....: L R.baf L � .. h-.br a.mfy tae t .. , - fqw a•'lartnw m Ar-S+tt nr m. � toa,( tka. a, tfil. iet a+d nwt a( th. • ,•••. .. ,:r::.JJ r' .... .. d"wnkne W4 efioAn ht4matku m .f.os, haaoni" • ROBE�i.TE. An. and no afcrwile" w nlst h"W FINAL STRUCTURE AS -BUILT �� �� "'✓ ;'•��AAI C Acb.1 E Xhnt &., ,,r.ny o tfPy ty.i I f' "."• Jt ^� .t.e_ k bt void hwt pCr ^e ,`.... ..•'`• tj �" mm.,.abn. awe h,anfatsm .. r.a., ,,..v, ���1�°� pro �a�a��•�• en tn.. ard no vvrarinects .ad, ul.pe i'� �e Sion�a� .�,'�. .no.., ou+rr.ioc �4r.te�d.� ONLY THOSE IMPROVEMENTS ABOVE GROUND AND VISIBLE WILL BE SHOWN. FENCES, WELLS, SEPTIC CLEANOUTS, SIDEWALKS, DRIVEWAYS, ETC., ARE SHOWN IN 71HEIR APPROXIMATE LOCATION, ONLY, SNOW MAY PREVENT SOME IMPROVEMENTS FROM BEING SEEN ANO LOCATED. ALL DISTANCES ARE RECORD UNLESS OTHERWISE NOTED. Prepared by Robert E. Johns, Jr. & Assoc. Professional Land Surveyors 1700 Brink Drive. ANCHORAGE, ALASKA 99504 q _ 50' Rac. Lot S.F. 04/18/14 Drawn by. REJ 04/18/14 Grid: 2222 Lot 10 Block 3 SKYHILLS PH 2 File No. W.O. 14-125 y. .. . , > . . : �. . .J. � k �,� \\�\� \� dye � «^ \.� ««»� < � �»���<�»\\ m, _ � � � r ^ �� . .a� � MUNICIPALITY OF ANCHORAGE DEPAFITMENT OF HEALTH & HUMAN SERVICES Oivision of Environmental Services On-Site Services Section P.O. Box 196650 Anchorage, Alaska 99519-6650 343-4744 CERTIFICATF OF HEALTH AUTHORITY _ - . '-" 'AP?ReVAL FOR A SlNG'LE FAMILY'~WELLIbrG ' ' 1.'. GENFRAL INFORMATION ', Complete legal description' Lot:.,10, Block 3, Sky. H~'11s Subclvfsion, Phase T'r LOCation ('site address'0r'dJrecti~ns) Propertypwnbr',: Cf~m POfnte, Inc. '~ .. ~:_ ~.'~._~,}~'/ ~.PO ;Box .l12313,Anchorage, AK~99511 · _~Lending agency" ;~ 'L _ Da~ phone Mailing address ' ~:'' ~ ' Agent Address ..Day Phone_ 345-6277 Day phone_ Unless otherwise requested, HAA will be held for pickup. 2. NUMBER OF BEDROOMS: ~6 (six)' . r3. .TYPE OFWATER SUPPLY: .. ' Individual well · ,~i .. ' .i.~....' community well* -' r --Public water xxk~x .... NOTE: If community well system, provide'written ConfirrnatiOn from State ADEC attest- lng to the legality and status of system, r rL . wAsTE'wATER DISPOSAl..:: 4. TYPE OF Individual on-site xxxxx · Holding tank · '- . Community on-site . Public sewer NOTE-': If community Wastewater system, provide written confirmation from State ADEC · attesting to the legality and status of system. ' ' ' ' ' 72-025[Ray. l/91) Front MOA#21 5. STATEMENT OF INSPECTION BY ENGINEER As certified by my seal affixed hereto and as of the validation date shown below, I verify that my investigation of this Health Authority Approval application shows that the on-site water supply and/or wastewater disposal system is safe, functional and ade(; uate for the number of bedrooms and type of structure indicated herein. I further verify that based on the information obtained from the Munici pality of Anchorage files and from my investigation and inspection, the on-site water supply and/or wastewater disposal system is in compliance with all Municipal and State codes, ordinances, and regulations in effect on the date of this inspection. Name of Firm : Anderson Engineering Phone 52J~7773 A~sS PO Box 240773 Anchorage, AK 99524 '' ' : '" ' ' 'Date il/11/99 Engineer's signature ApprOved for ~i ~' bedrooms. Disapproved. Conditional approval for ' · ipulafio :' g st ns: I~drooms, with the followin Additional Comments By: The Municipality of Anchorage Department of Health and Human Services (DHHS) issues Health Authority Approval Certificates based only upon the representations given in 'paragraph 5 above by an independent professional engineer registered in the State of Alaska. The DHHS does this as a courtesy to pumhasers of homes and their lending institutions in order to satisfy certain federal and state requirements. Employees of DHHS do not conduct inspections or analyze data before a certificate is issued. The Municipality of Anchorage is not responsible for errors or omissions in the professional engineer's work. Municipality of Anchorage NOV ] ,~"]999/~ DEPARTMENT OF HEALTH & HUMAN SERVICE~nic~^Ln'Y oe Environmental Services Division ENVIRONMENTAL SERVICES I 82!5 L Street, Reom 502 · Anchorage, Alaska !)9501 · (907) 343-4744 Health Authority Approval Cl~ecklist Legal Description: Lot 1 0, Block 3, Sky Hills Phase II A, WELLDATA - Municipal Water System Well type Log present (WN) Total depth __ Sanitary seal (Y/N) Parcel I.D.: 011 -1 22-36 IfA, B, or C, attach ADEC letter. Ar)EC water system number Date completed Cased to Casing height (above ground) Wires properly protected (Y/N) AT INSPECTION FROM WELL LOG g.p,m. Date of test Static water level Well production WATER SAMPLE RESULTS: Coliform Date of sample: B. SEPTIC/HOLDING TANK DATA Date installed 5 / 21 / 99 Foundation cleanout (Y/N) Nitrate Other bacteria g.p,m. Collected by: Tank size 2,000 Number of Cornpartments 2 C eanouts (Y/N). Y Y Depre~ion (Y/NJ N High water alarm (Y/N). N Date of Pumping New Pumper Construction C. ABSORPTION FIELD DATA Date installed 5 / 21 / 99 Soil rating (g.p.d,/ff~ or ff~/bdrm) .6 Length _ 78 ' Width 3 ' . Gravel thickness below pipe Effective absorption area 1 ~ 248 SF Monitoring Tube present (Y/N) Y Date of adequacy test New Const, Results (Pass/Fail) Pass Fluid depth in absorption field before test (in.); __ Fluid depth (ins) Minutes later: Peroxide treatment [past 12 months) (Y/N) N System type Deep Tren_ch 1 0 ' Total depth _1 3,5 ' _ _ DePression over field (Y/N) N For 6 .bedrooms _ Immediately afte~ gal, water added (in.): __ Absorption rate = .g.p.d. If yes, giw~ date N?A 72-026 (Rev. 3/96)* D. LIFT STATION None on Lot Date instal[ed Manhole/Access (Y/N) High water alarm level at* Cycles tested E. SEPARATION DISTANCES SEPARATION DISTANCES FROM WELL ON LOT TO: Septic/holding tank on lot Absorption field on lot Public sewer main Sewer/septic service line Size in gallons "Pump on" level at* *Datum No Well on Lot On adjacent lots On adjacent lots Public sewer manhole/cleanout Lift station SEPARATION DISTANCES FROM SEPTIC/HOLDING TANK ON LOT TO: Foundation > 5 ' Property line > 5 ' ' Absorption field Water main/service line > 1 0 ' .Surface water/drainage > 1 00 ' SEPARATION DISTANCE FROM ABSORPTION FIELD ON LOT TO: Property line > 1 0 ' Building foundation > 1 0 ' Surface water > 1 O0 ' Curtain drain None Noted on Lot Wells on adjacent lots >100' F. ENGINEER'S CERTIFICATION I certif~ · in conformance with MOA HAA guidelines in effect on this date. Signature ~ ~tr~t'~'~ Engineer's Name M~chael E. Anderson~ P.E. Date 11 /11 /99 >5' Wells on adjacent lots Driveway, parking/vehicle storage area "Pump off" level at* Water main/service line >10 >100' >10' HAA Fee $ Date of Payment Receipt Number Waiver Fee $ Date of Payment Receipt Number 72-026 (Rev. 3/96)*