Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
SKYLINE VIEW BLK 1 LT 16
Skyline View Block 1 Lot 16 #051-192-39 Municipality of Anchorage r'age DEPARTMENT OF HEALTH AND HUMAN SERVICES ENVIRONMENTAL SERVICES DIVISION P.O. Box 196650 · Anchorage, Alaska 99519-6650 · Telephone: 343-4744 On-Site Waslewaler Disposal Syslem and/or Well Inspection Reporl Pe,mi! Number: ~ L~,)~ '70 ~ PlO Number: *~'~':[o~ ~? ~/¢ {;v~.~ ~7~ ABSORPTION FIELD LEGAL DESCRIPTION WELL: ~ New O Upgrade SEPARATION DISTANCES ~s..~;~ g I Ioldlng g S.T.E.P. Water ~J~ I001+ ~ LIFT STATION Remarks: BENCH ~ARK 17034 Eagle River Leap Road, No. Inspections performed by:E~v~ Dates: 1st I 0-~1- ~ ~~ :~. . Department of Heallh andHuman Services approval . Reviewed and approved by: Dale: / ' PER~flT NO SW970572 PAGE 2 OF 5 Municipoti¢ oF Anchor~Qe DEPARTMENT OF HEA~THAND HUIVFAN SERVICES ENVIRONHENTAL SERVICES DIVISION P.O. Box ]96650 ~nchoroge, Alosk~ 99519-6650 · TeleDhone: 343-4744 ON-SITE WASTEWATER UISPOSAL SYSTEM AND/OR WELL INSPECTION REPORT LECAL LOT ~6~ BLOCK 1~ SKYLINE VIEW S/D P.i.m NO. 05]-~92-~9 ~ LOT 17 OALLON SEPTIC TANK_ ir~ ~1 ' - e LI Es' MIN.~ - o&~Oo ~ ~// I ~~ '~"'"' ~ '"'~'~'" ~ LOT X ~ ,..~-~....~-~.;.~.~ P£R.MIT NO SW970572 PAGE 3 OF 3 Municip. olit.. _y_..oF AnchomoQe DEPARTMENT OF HEALTH AND HUMAN SERVICES ENVIRONMENTAL SERVICES DIVISION P.O. Box 196650 ~Amchoroge, Alosko 99519-66500Telephone: 343-4744 ON-SITE WASTEWATER DISPOSAL SYSTEM AND/OR WELL INSPECTION REPORT LEGAL LOT 16, BLOCK 1, SKYLINE VIEW S/D P.I,D, NO. 051-192-39 ST1 FINAL GRADE/ NEW 1000 GALLON SEPTIC TANK 98.4' A B FCO 14.0' 27.0' ST1 58.5' 26.5' ST2 44,0' 28.5' DBL1 46.0' 50.0' DBL2 47.0' 31.0' CO1 63.0' 41.5' MT1 62.0' 49.0' C02 39.0' 55.5' CO1 CO2 ~{T1._JCO1 = 98.9' / ICO2 = 97.2' /FINAL GRADE ~_~CO1 = 91.9' C02 91.9' ~-MT1 = 88.3' A NO WATER FOUND 82.3' B.O.H. ROBERT C. COWAN, RE. ROBERT A. SHAFER, P.E. SS~/E R & WATER MAIN EX J EN.BION9 ,.BEWER & WA1'ER INgPECJlON ENglNEEItlNG 81UDIE9 AND REPORTS WELL INSPEO]FON & FLOW TE.BT $1'[E pLANS ROAD DE.BIGN SOIL IE.BT PERCOLATION .BT RUOTURAL & MECHANICAL INSPECTIONB ON.BITE WASTEWA~ER DISPC~AL $YSTEM OEBION Date: CIVIL ENGINEERS (907) 694-2979 FAX (907) 694-1211 Municipalit,y of Anchorage DEPARTMENT OF HEALTH AND HUMAN SERVICES 825 L Street, P.O. Box 196650 Anchorage, Alaska 99519-6650 REC !!VED NOV 5 199'/ Municipality of Anchorage Dept. Health & Human Services Tile septic inspections for the referenced property were performe~ on 10-Zl-gl and fo-Z~-9~ . Prior to submitting t,he On-s~te Wa~e~r Disposal System and/or Well Inspection Report we are waiting for t,he ~o~D~ to be complet,ed. If we may be of further service please contact us. Sincerely, Robert. C. Cowan~ ~.E, 17034 NORTH -EAGLE RIVER LOOP, SUITE 204, EAGLE RIVER, ALASKA 99577 PAGE 1 OF MUNICIPALITY OF ANCHORAGE DEPARTMENT OF HEALTH AND HUMAN SERVICES P.O. BOX 196650, 825 "L" STREET, ROOM 502 ANCHORAGE, ALASKA 99519-6650 ON-SITE WASTEWATER DISPOSAL SYSTEM PERMIT PERMIT NUMBER:SW970372 DESIGN ENGINEER:S & S ENGINEERING OWNER NAME:BENEDIKTSSON CHRIS M OWNER ADDRESS:P.O. BOX 4534 EAGLE RIVER, ALASKA 99517 DATE ISSUED:10/15/97 EXPIRATION DATE:10/15/98 PARCEL ID:05119239 LEGAL DESCRIPTION: SKYLINE VIEW BLK 1 LT 16 LOT SIZE: 15750 (SQ. FT.) NUMBER OF BEDROOMS: 3 THIS PERMIT: 3 THIS PERMIT IS FOR THE CONSTRUCTION OF: DISPOSAL FIELD /SEPTIC TANK SYSTEM ALL CONSTRUCTION MUST BE IN ACCORDANCE WITH: 1. THE ATTACHED APPROVED DESIGN. 2. ALL REQUIREMENTS SPECIFIED IN ANCHORAGE MUNICIPAL CODE CHAPTERS 15.55 AND 15.65 AND THE STATE OF ALASKA WASTEWATER DISPOSAL REGULATIONS (18AAC72) AND DRINKING WATER REGULATIONS (18AAC80). 3. THE ENGINEER MUST NOTIFY DHHS AT LEAST 2 HOURS PRIOR TO EACH INSPECTION. PROVIDE NOTIFICATION BY CALLING 343-4744 ( 24 HOURS ) (NOT REQUIRED FOR WELL ONLY PERMIT) 4. FROM OCTOBER 15 TO APRIL 15 A SUBSURFACE SOIL ABSORPTION SYSTEM UNDER CONSTRUCTION DURING FREEZING WEATHER MUST BE EITHER: A. OPENED AND CLOSED ON THE SAME DAY B. COVERED, SEALED AND HEATED TO PREVENT FREEZING 5. THE FOLLOWING SPECIAL PROVISIONS. SPECIAL PROVISIONS: RECEIVED BY: ~ DATE: ROBERT C. COWAN, P.E. CIVIL ENGINEERS October 10, 1997 (9O7) 694-2979 FAX (907) 694-1211 SO~L TEST MUNICIPALITY OF ANCHORAGE Department of Health and Human Services P.O. Box 196650 Anchorage, AK. 99519 REFERENCE: Lot 16, Block 1, Skyline View Subdivision Request you re-issue a permit to install a septic system to serve the proposed three bedroom house on the referenced property. The well has been drilled under permit #SW950299. Attached is the previously submitted design and a cop)' of the new well log. A test hole was excavated and percolation test performed. The approximate location of the test hole is located on the attached site plan. At the time of excavtion, no water was found in the test hole. After seven day groundwater monitoring, the monitoring tube within the test hole has been checked and was found to be dry. We do not anticipate any adverse effects on neighboring wells, septic systems or drainage patterns by the installation of the proposed septic system. lfyou require additional information, please contact us. Sincerely, Roberl C. Cowan, P.E. RCC/jlm Enclosure 17034 NORTH EAGLE RIVER LOC}P · SUITE 204 · EAGLE RIVER. ALASKA 99577 1" = .30' ~OALE 0 SITE PLAN I-- DESIGN I --t Z --.t ~0~ 0~0 ~Z m~ PAGE 1 OF 1 MUNICIPALITY OF ANCHORAGE DEPARTMENT OF HEALTH AND HUMAN SERVICES P.O. BOX 196650, 825 "L" STREET, ROOM 502 ANCHORAGE, ALASKA 99519-6650 ON-SITE WELL AND WASTEWATER DISPOSAL SYSTEM PERMIT PERMIT NUMBER:SW950299 DESIGN ENGINEER:S & S ENGINEERING OWNER NAME:BENEDIKTSSON CHRIS M OWNER ADDRESS:P~O. BOX 4534 EAGLE RIVER ALASKA 99577 DATE ISSUED: 9/28/95 EXPIRATION DATE: 9/28/96 PARCEL ID:05119239 LEGAL DESCRIPTION: SKYLINE VIEW BLK 1 LT 16 LOT SIZE: 15750 (SQ. FT. NUMBER OF BEDROOMS: 3 THIS PERMIT: 3 THIS PERMIT IS FOR THE CONSTRUCTION OF: DISPOSAL FIELD /SEPTIC TANK / WELL SYSTEM ALL CONSTRUCTION MUST BE IN ACCORDANCE WITH: 1. THE ATTACHED APPROVED DESIGN. 2. ALL REQUIREMENTS SPECIFIED IN ANCHORAGE MUNICIPAL CODE CHAPTERS 15.55 AND 15.65 AND THE STATE OF ALASKA WASTEWATER DISPOSAL REGULATIONS (18AAC72) AND DRINKING WATER REGULATIONS (iSAACS0) . 3. THE ENGINEER MUST NOTIFY DHHS AT LEAST 2 HOURS PRIOR TO EACH INSPECTION. PROVIDE NOTIFICATION BY CALLING 343-4744 ( 24 HOURS ) (NOT REQUIRED FOR WELL ONLY PERMIT) 4. FROM OCTOBER 15 TO APRIL 15 A SUBSURFACE SOIL ABSORPTION SYSTEM UNDER CONSTRUCTION DURING FREEZING WEATHER MUST BE EITHER: A. OPENED AND CLOSED ON THE SAME DAY B. COVERED, SEALED AND HEATED TO PREVENT FREEZING 5. THE FOLLOWING SPECIAL PROVISIONS. SPECIAL PROVISIONS: ISSUED BY: t DATE: ROBERT C. COWAN, RE. ROBERTA. SHAFER, RE. HEALTH AUTHORITY APPROVALS S EWER & WATER MAIN EXTENSIONS SEWER&WATER INSPECTION ENGINEERING STUDIES AND REPORTS WELL INSPECTION & FLOWTEST SITE PLANS ROAD DESIGN SOIL TEST PERCOLATION TEST STRUCTURAL & MECHANICAL INSPECTIONS ON SITE WASTE~/ATE R DISPOSAL SYSTEM DESIGN September 14, 1995 CIVIL ENGINEERS (907) 694-2979 FAX (907) 694-1211 MUNICIPALITY OF ANCHORAGE Department of Health and Human Services P.O. Box 196650 Anchorage, AK. 99519 REFERENCE: Lot 16, Block 1, Skyline View S/D Request you issue a permit to drill a well and install a septic system to serve the proposed three bedroom house on the referenced property. Two test holes were excavated and percolation tests performed. The approximate location of the test holes are located on the attached site plan. At the time of excavation no water was encountered in the test holes and after seven day ground water monitoring, the monitoring tubes were found to be dry. This property has enough area for a future septic upgrade which can be seen on the attached site plan. We do not anticipate any adverse effects on neighboring wells, septic systems or drainage patterns by the installation of the proposed septic system. There are no points of contamination within the proposed well radius which can be seen on the attached site plan. If you require additional information, please contact us. Sincerely, Robert C. Cowan, P.E. RCC/ k Enclosure 17034 NORTH EAGLE RIVER LOOP · SUITE 204 . EAGLE RIVER, ALASKA 99577 SITE PLAN 0 0 0 0 co ~_aJ' o :8 ~tn o ~ m ~ m I DESIGN '~00 2I> --< -< ~ Z © ~AL~ SITE PLAN Municipality of Anchorage DEPARTMENT OF HEALTH & HUMAN SERVICES 825 "L" Street, Anchorage, Alaska 99502-0650 SOILS LOG -- PERCOLATION TEST PERFORMED FOR: LEGAL DESCRIPTION: 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 1 2 3 4 vl/&d & ¢ ~ ROBERT C. 6OWAN ~,~ ~ DATE PERFORME~:),"~71 -~'~f- ~. '~, ~ ~/~ Township, Range, Section: ~ SLOPE SITE PLAN WAS GROUND WATER . \ ENCOUNTERED? ~ O IF YES, AT WHAT L DEPTH? /~ pO E Depth Io Water Alter Monitoring? ~,c~/ Date: Gross Net Depth to Net Reading Date Time Time Water Drop PERCOLATION RATE '~ tmmutes/~nch) PERC HOLE DIAMETER TEST RUN BETWEEN q FT AND__~'~ FT COMMENTS S & $ ENGINEERING ,¢ PERFORMED BY: ........... h ~-,; .... , --~,~%~LM~_O(}-~I~f,~vcv~ '~ b CERTIFY THAT THIS TEST WAS PERFORMED IN ACCORDANCE WITH ~''~A~~GUIDELINES IN EFFECT ON THIS DATE. DATE: 72-008 (Rev. 4/85) PERFORMED FOR: Municipality of Anchorage DEPARTMENT OF HEALTH & HUMAN SERVICES 825 "L" Street, Anchorage, Alaska 99502-0650 SOILS LOG m PERCOLATION TEST 2 4 ,~ 5 6 7 8 9 10 11 12 13 14- 15- 16- 17 18 19 2O ' '-'.. ---~ '. ' -Z ~ Township, Range, Section: SLOPE SITE PLAN WAS GROUND WATER ENCOUNTERED? IF YES. AT WHAT ~'k DEPTH? V~' pO E Depth 1o Waler Alter Monitoring? '~ ~'"[ Date: I Gross Net Depth to Net Reading Date Time Time Water Drop PERCOLATION RATE ~ (m~nutes/mch} PERC ROLE DIAMETER TEST RUN BETWEEN c/ FT AND . ~-- FT COMMENTS PERFORMED BY: $ & $ ENGINEERING 17034 Eagle River Loop ACCORDANCE WIT~j~C~.,E,A~D~'~i~IN~I~A'"~_ GUIDELINES IN EFFECT ON THIS DATE. DATE: 72-008 (Rev. 4/85) ROBERT C. COWAN, R E. ROBERTA. SHAFER, RE. HEALTH AUTHORITY APPROVALS SEWER&WATER MAIN EXTENSIONS SEWER&WATER INSPECTION ENGINEERING STUDIES AND REPORTS WELL INSPECTION & FLOW TEST SITE PLANS ROAD DESIGN SOILTEST PERCOLATION TEST STRUCTURAL & MECHANICAL INSPECTIONS ONSITE WASTEWATER DISPOSAL SYSTEM DESIGN ON-SITE WASTEWATER DISPOSAL SYSTEM CONSTRUCTION PRACTICES and MATERIAL SPECIFICATIONS CIVIL ENGINEERS (907) 694-2979 FAX (907) 694-1211 REFERENCE: Lot 16, Block 1, Skyline View S/D September 15, 1995 GENERAL: 1. e The scope of this project includes the installation of a 1000 gallon septic tank and five foot wide drainfield to serve the proposed three bedroom residence for the referenced property. Construction shall be in accordance with the approved site plan and design drawings, Municipal permit with any special provisions or conditions, and all applicable State and Municipal Wastewater Disposal Regulations. The contractor shall be responsible for obtaining any necessary underground utility locates. Unless specifically agreed otherwise, the property owner shall be responsible for final grading areas subsequently depressed from soil settling. On all leachfield mound systems, 'the property owner shall be responsible for ensuring a satisfactory vegetation growth over the mounded area. Contractors installing wastewater disposal systems must be certified by the Municipal Health Department for system installations. Owners installing their own systems must also receive prior approval from the Municipal Health Department. SEPTIC TANK INSTALLATION: A septic tank is to be constructed by a certified septic tank manufacturer. Construction shall include two 4" cleanouts for pumping access. The septic tank shall be sufficiently bedded to prevent settling or shifting of the tank. Ail standpipes on the septic tank shall extend a minimum of 12 inches above final grade. 17034 NORTH EAGLE RIVER LOOP · SUITE 204 o EAGLE RIVER. ALASKA 99577 Page Two Lot 16, Block 1, Skyline View S/D September 15, 1995 4e Septic tanks installed with less than 4 ft. of cover shall be insulated. A foundation cleanout shall be installed one to four feet from the building foundation. In the line between the tank and the leachfield there shall be two adjacent cleanouts (unless an effluent pumping system exists within the septic tank). These cleanouts shall be located on undisturbed soil not more than 10 ft. from the tank. The first cleanout, in line, shall be to clean toward the leachfieldo The second cleanout shall be to clean toward 'the septic tank. Final grading over the septic tank shall be such that a positive slope exists away from the septic tank. ABSORPTION TRENCH/DRAINFIELD INSTALLATION: Ne Excavate the proposed trench to the dimensions shown on the design. The bottom of the excavation shall be within 2 inches of level. If the sidewalls of the excavation become smeared, they must be raked or scratched (ruffed-up) before gravel (sewer rock) placement. e Once the gravel is installed, the distribution pipe is to be installed level with the perforations faced downward. Gravel is then to be placed over the distribution pipe to provide a minimum of 2 inches of cover over 'the pipe. A silt barrier must be installed between the final gravel layer and the native soil backfill. Ensure the silt barrier covers the entire gravel surface before placing backfill. Monitor tubes shall be of four (4) inch diameter, installed approximately in the locations shown on the design, and extend a minimum of 12 inches above final grade. The portion of the monitoring tube extending through the gravel shall be perforated from the bottom of the trench to the invert of the distribution pipe. This is equivalent to the effective depth of the gravel as noted on the design. Backfill over the final gravel layer must not be less than twenty-four (24) inches. Insulation must be installed when the backfill depth is less than thirty-six (36) inches. The finish grade over the trench must be mounded to prevent the formation of a depression after settling. Page Three Lot 16, Block 1, Skyline View S/D September 15, 1995 MINIMUM MATERIAL SPECIFICATIONS: Any septic tank proposed for installation must be constructed by a Municipally approved septic tank manufacturer. The following pipe materials are approved for use in septic system installations in the Municipality of Anchorage: Type of Pipe Perforated Solid Cast Iron ASTM D3034 (PVC) ASTM F810 (HDPE) ASTM D2662 (ABS) Yes Yes Yes Yes Yes No Yes Yes Use of a type of pipe other than listed above must be approved by the inspecting engineer. Insulation shall be at least 2" thick extruded direct burial pelystyrene (Dow Chemical Company Styrofoam HI or equal)· Septic tank inlets and outlets shall be fitted with watertight couplings (Caulder, Fernco, or equal). A permeable nontoxic silt barrier (Typar 3401, Mirafi 140N, or equal) must be installed between the final leachfield gravel layer and the native soil backfill. Ail leachfield gravel (sewer rock) shall be 0.5"-2.5" screened gravel with less than 3% passing the t~200 sieve. When sand is being used as a filter material, its gradation specifications must conform to current M.O.A. or D.E.C. requirements. Page Four Lot 16, Block 1, Skyline View S/D September 15, 1995 INSPECTIONS: Typically there will be a minimum of three (3) inspections required during the installation of the wastewater disposal system. These inspections will occur as follows: The first inspection must be conducted after the excavation of ditches, pits, trenches, or beds and before the installation of any gravel. A septic tank may be set in place, but may not be backfilled before this inspection. The second inspection must be conducted after the placement of the silt barrier, gravel, distribution lines, standpipes, cleanouts, and insulation, but before the placement of any other backfill. The final inspection is to occur upon final grading of the property. Often there will be more than these 3 inspections required° Especially with the installation of multiple trenches, sand filters, pressurized distribution systems, etc. Thus, the inspecting engineer is to be contacted at least 24 hours prior to the start of construction. If necessary, a pre-construction meeting will take place on-site. The inspecting engineer will not coordinate, direct or control in any way the contractors activities. The owner shall contract with the contractor to perform the work outlined in these specifications and plans and in accordance with the attached M.O.A. permit. There will be no contractual arrangement existing between the contractor and S & S Engineering. S & S Engineering shall be the owner's representative and will inspect the work as stated above to document the contractors activities. Final acceptance of the contractors work rests with the owner and the M.O.A. S & S Engineering shall have no liability to the owner or to others for acts or omissions of the contractor or any other persons performing work on this project or the failure of the contractor to carry out the work in accordance with these construction documents. S & S Engineering's inspecting engineer will not be responsible for the construction means, methods, techniques, sequence, procedures or the safety precautions incident to this project. CONTRACTOR/O~ER 0 0 0 0 0 0 0 0 0 0 0 0 Ii