Loading...
HomeMy WebLinkAboutSLEEPY HOLLOW #1 BLK 2 LT 6Sleepy Hollow #1 Block 2 Lot 6 #051-501-11 Municipality of Anchorage `�' • Development Services Department Building Safety Division - On -Site Water and Wastewater Program, 4700 S. Bragaw Sl. P.O. Box 196650 Anchorage, AK 99519-6650 Page of www.cl.anchorage.ak.us (907) 343-7904 ON-SITE WASTEWATER DISPOSAL SYSTEM AND/OR WELL INSPECTION REPORT Permit Number. SW990310 PID Number. 051.501.11 N s a Gore Wastewater System: ® New ❑ Upgrade Adaefs: iada Drive, Chligiak. AK 99567 ABSORPTION FIELD p1m*: N~ Of Be 11: O Deep Trwxh® Shah" Twch O Bed 0MWM othr: Sa Raleq Taal Depth van ongnr pale: LEGAL DESCRIPTION 1.2 GpolF? 6.54 Fl. SINX Lot swdmenn: Depth W pw baton ham orpnal Waft: Gavel depth beneath p" 2 6 Sleepy Hollow#1 2.24 Ft. 4.30 FI Tpensh9: Range: seam: FA added tl ageal Waft. Gravel Length: 50 0,23 Ft. Fl. Well: r-1New❑ Upgrade GrMl,e,ddl'. 5 NumbersWs: 1 Drrea tMlwNnYrW: alNA Ft Fl. clew"M tp M*. A B. CI Tar Depox Caved a-. Tar ansom" rN. 500 Poe Mgmal'. D3034 & F810 A 213522 Ft. Ft FT Drager. Dale Meted, $IalC Welr L": "Mier.. Everett Caulkins Dale crawled'. 1011111999 Ft pump Sol al'. ca" H -q* Above Graaet. TANK GPM FI. Ft SEPARATION DISTANCES 0 Septic ❑ Holding ❑ S.T.E.P. ❑ other. To Septic Absorption Lift Holding Pubditlprivat ed... Anchorage Tank aD�v 1250 Gal. From Tank Field Station Tank Sewer Lane MrrW: Number a canprvneas. well 2001+ 200'+ NA NA 25'. Steel 2 1001+ 1004 NA NA LIFT STATION Safari wider 5'+ 10'+ NA NA Gr. La Lia 5'+ 10'+ NA NA 'Pump m' lour M'. 'Pump ow level al Hqh ran. •arm M. et FaMel�m L,. „_ NA a50'+ NA NA Pump Melee a Model EadnW m vrpedaprfaned by C~ Drain Rrnr.s: BENCH MARK *none known Loulm and D•aapbat Top of foundation 100 FL Engineers Stamp OF At \I Inspections performed by: KND Engineering Dates: 1" 1011111999 OF * i� ►1 a t,9 2nd 1011411999 • • • NN•NNN •NNN •N t I J Development Services Department Approval 03/3010, - NKenneth M. Du' Date: y -.Z 3- o I ,I0,F ; OE 7116 Vagi . Reviewed and approved by "1, 5; •••: t`41\RO ran llbo) ES �P`+� S81.55'10•E 349,14 487.3 ETER*SPOT EL '/ CREEK muort dl "SLOT 6 co BLOCK 2 SLEEPY W �!. HOLLOW SUBD , a \ 0 2 e* \50 LOT 4 No9.9 of 0197 12' WIDE \ ORNNAY �SOSJ FOUNDATION V\ NEW HOUSE F.F. 301.5 LOT S d � k n 0 N LOT 7 Z �J TRUE N VA,V[TS NOTES 1. SPOT ELEVATIONS ARE ON AN ASSUMED LOCAL DATUM. 2. WATER SERVICE FOR LOT 6 IS BY CLASS 'C' COMMUNITY WELL LOCATED APPROX. 700' TO THE SOUTH—WEST. FND 5/8 V 192.82' R -J91.8• 03,32 SCALE: 1'.100' BAR REMP) SURVEYED: 7/18/99 S L E E P Y C I R C L E BY: Du DRAWN: 7/16/99 BY:M ASB U I LD SURVEY AM EILE C.\ORAMNCS\9 LOT 6, BLOCK 2 SLEEPY HOLLOW SUBD. #1 ark�0� oqc,, I, DAVID L LUCAS, RLS 08263, HEREBY CERTIFY THAT I HAVE SURVEYED THE ABOVE sp�*••w• m CITED PROPERTY; AND THAT THE IMPROVEMENTS SITUATED THEREON ARE WITHIN THE i •�� PROPERTY LINES AND DO NOT OVERHANG OR ENCROACH ON PROPERTY ADJACENT THERETO, ••�•••••• « AND THAT NO IMPROVEMENTS ON ADJACENT PROPERTY OVERHANG OR ENCROACH ON THIS DAVW Lia PROPERTY, AND THAT THERE ARE NO ROADWAY, UTILITY OR OTHER VISIBLE EASEMENTS ON SAID PROPERTY, EXCEPT AS INDICATED HEREON. YRUE chow,. com or Y Docwoa w o rxlr Fu .,a 8uA R.e u: P D w.acs f t� oA/�y�•_••«w•'• TDIIC' AInOTW ¢IID%fL-/C DnD cmoil) PUllf%IAV AV nntZC-7 000 n 4 w Im AS—BUILT SYSTEM DETAILS/SITE PLAN Permit SW990310 SLEEPY HOLLOW S/D #1, LOT 6, BLOCK 2 PID#051-501-11 r i #S 94-1 KND SEPTIC �o T # N 9-2 TH #KND99-1 3 E PROPOSED RESERVE C mT C O7WELL.. .. APPR E LOCATION Or WATER LINE A—C=19.9' B—C=13.6' d FINAL GRADE A—D=25.9' X� B—D=20.8' A—E=79.5' 1250 GAL 5 B—E=77.8' "-SEPT SEPTIC94.9 TANK SEWER ROCK .................. 9F 4�4's-. KENNETH M. Ers %CE -7110 .................... ssloll" -.OF PREPARED FOR: EVERETT CAULKINS (907)696-0246 FIELD BOOKS co~m. 9ww' I UCAS DRAW V13O — STAKNQ LUCAS a10= KMD Awu T' LUCAS— OAM 3/30 m nm GFAM NW1161 ACRD "L'99047.DWG 99047 SCALE, NTS V - 50' VM= &U\UW ENGINEERING 20441 PTARMIGAN BLVD. EAGLE RIVER, AK 99577-87361 UA I = ME -('60LFj6Y2 Po�07//9-9 Permit Number. SW990310 MUNICIPALITY OF ANCHORAGE Department of Health and Human Services On -Site Services Program 825 L Street, Room 502 P.O. Box 196650, Anchorage, AK 99519-6650 (907) 343-4744 ONSITE WASTEWATER DISPOSAL SYSTEM PERMIT Initial Legal Description: SLEEPY HOLLOW #1 BLK 2 LT 6 I��GM M yt lc -11.11 - ?7 Date Issued: Sep 01, 1999 Expiration Date: Aug 31, 2000 Parcel ID: 051-501.11 Design Engineer. 0070 KND Engineering Site Address: 023741 SLEEPY CIR Owner Name: Lisa Gore & Everett Caulkens Lot Size: 195425 SO. FT. Owner Address: 20049 Tanada Drive Total Bedrooms: 4 Permit Bedrooms: 4 Chugiak , AK 99567 - This permit Is for the construction of: ❑? Disposal Field ❑✓ Septic Tank ❑ Holding Tank ❑ Privy ❑ Private Well ❑ Water Storage All construction must be in accordance with: 1. The attached approved design. 2. All requirements specified In Anchorage Municipal Code Chapters 15.55 and 15.65 and the State of Alaska Wastewater Disposal Regulations (1 SAAC72 ) and Drinking Water Regulations (18AAC80 ). 3. The engineer must notify DHHS at least 2 hours prior to each Inspection. Provide notification by calling (907) 343-4744 ( 24 hours ). ( Not required for a Water Supply Permit only ). 4. From October 15 to April 15, a subsurface soil absorption system under construction during freezing weather must be either. A. Open and closed on the same day. B. Covered, sealed, and heated to prevent freezing. Received By: Issued By: Date:9 -' 1 Date: 9199 ��ND ENGINEERING 20441 PTARMIGAN BLVD. EAGLE RIVER, AK 99577-8736 11/FAX (907)696-8111 August 7,1999 Municipality of Anchorage Dept. of Health & Human Services On -Site Services Section P. O. Box 196650 Anchorage Alaska 99519-6650 Subject: ' New sewer permit — Sleepy Hollow SID t, Lot � B4 2 Gentlemen: The owner has requested we proceed forward to obtain a septic permit on the subject lot. On June 16, 1999 we dug one testhole for the proposed system. The results of this test is attached. A previous testhole was excavated in 1994 and we have attached the results of that testhole for your reference. The general slope of this lot is from north to south at a grade of approximately 2 - 5% for the southern two-thirds of the property. The northern third of the property has slopes in excess of 25%. We have designed our system utilizing the testhole we excavated for the three-bedroom house, which is proposed for this lot. The lot will be served by a class "C" well. We propose to install a 5' wide shallow trench due to the sloughing encountered during the excavation. The lower soils strata was not percolated as it only had trace silt noted and appeared significantly to be made of the same material. Water was not encountered during the excavation or monitoring. There are no public or private wells within 200' of our proposed system location except as noted. There is no surface water within 100' of the proposed system and there are no known curtain drains within 50'. We do not expect there to be any adverse effect on adjacent lots by the development of this system. If you have any questions, please contact me at 696-6111/FAX 696-8111. Respectfully submitted, Keth gineeringg M. Duffus, P.E. attachments: On -Site Well and Sewer Application Wastewater Absorption System Details/Site Plan Soils Log/Percolation Test WASTEWATER DISP❑SAL SYSTEM DETAILS/SITE PLAN SLEEPY HOLLOW S/D #1, LOT 6, BLOCK 2 K � D NO PUBLIC WELLS WITHIN ew Q PROPOSED SYSTEM. NO PRIVATE WELLS WITHIN 200' Or PROPOSED SYSTEM EXCEPT AS NOTED. NO SEPTIC SYSTEMS WITHIN 200' Of PROPOSED WELL EXCEPT AS NOTED. ia by4W Vacant 7 4 S! B X QTX IS $94-I Iifl iT. F7 Vacant QTX a 099-I MWrti HmnE -WELL nF' y4 SEPTIC OF ALq �' 1 Q UFFUS 16 �a "wESS10110, DESIGN DETAILS 4 BDRM X 150 GPD = 600 GPD 600 GPD/1.2 GPD PER SO. FT. (1.5 MIN/IN.)= 500 SO. FT (500/5'(W)) X .50(RF) (4.0' GRAVEL) = 50 FT. TRENCH USE 1 TRENCH - 50<L) X 5' (W) X 4'(D) Total depth of system Is 7.0' from original grade. Total depth of gravel below distribution pipe Is 4.0' . NOTES: 1. USE 1250 GALLON SEPTIC TANK. INSULATE TANK IF <4' COVER. 2. INSULATE TRENCHES WITH 2' HD BURIAL FOAM. 3. CONTRACTOR WILL ENSURE MAXIMUM 2% SLOPE INTO SEPTIC TANK. 4. CONTRACTOR WILL ENSURE ALL SEPARATIONS TO ADJACENT WELLS b SEPTICS. PREPARED FOR, LISA GORE 20049 TANADA DRIVE CHUGIAK, AK FIELD BOOKS COMPUTED. BOUNOARri _ DRAm: KM sAXmc _ CHECXED: KMD ASSUlLT: _ DATE: 816/9 OK. FILE: CRUD: NW116 ACRD FILE:99047.DWG JOB N" 99047 Scale, 1'= 100' PAGE 1 OF 2 M�JLNI IU) ENGINEERING 20441 PTARMIGAN DLVD. EAGLE RIVER, AK 99577-8736 I WASTEWATER DISP❑SAL SYSTEM DETAILS SLEEPY HOLLOW S/D #1, LOT 6, BLOCK 2 L KD PREPARED FOR, LISA GORE 20049 TANADA DRIVE CHUGIAK, AK FIELD BOOKS eaNOMn _ STMiNG _ AS 10: _ owe. nit: AM riLV 99047 CWF%InD: DRAM: KMD CHECKED: KMD DATE: 8/6/9 GM NW1161 " Nn: 99047 S94-1 SYSTEM D99-1 PROPOSED RES Scale: 1'= 20' PAGE 2 OF 2 LtLll LL)) ENGINEERING 20441 PTARMIGAN BLVD. EAGLE RIVER, AK 99577-6736 —6 KININ ENGINEERING 20441 PTARMIGAN BLVD. EAGLE RIVER, AK 99577-8736 Performed for: 1- 2- 3- 4- 5- 6- 7- 8- 9- 10- 11- 12- 13- 14- I5- 16- 17- 18- 19- 20- Depth SOILS PERCOLATION TEST Org.- rootmat GP/GW —Loose, gray, slight silt SP/GP -mixed in layers B.O.H. #1 TEST HOLE # 99-1 SEE ATTACHED SITE PLAN FOR HOLE LOCATION Was Groundwater encountered? NO What depth? Depth to water after monitoring? Dry Date? 6/73/99 Reading Date Gross Time Net Time Depth to Water Net Drop 1 6/16/99 1:00 - 10" - 2 1:10 10 min 3 1/4" 6 3/4" 3 1:11 - 10" - 4 1:21 10 min 3 3/8" 6 5/8" 5 • 1:22 10- 6 132 10 min 3 3/8" 6 5/8" 7 • 133 10" - 8 1:43 10 min 3 1/4" 6 3/4" 9 ' 1:44 - 10" - 10 1:54 10 min 33/8" 6 5/8" 11 • 1S5 - 10" - 12 2:05 10 min 3 3/8" 6 5/8" Percolation Rate 1.5 (min/in) Perc Hole Diameter 6" Test Run Between 4 feet and 5 feet HOLE PRESOAKED PRIOR TO TESTING I, Kenneth M. Duffus, certify that this test was performed in accordance with all State and Municipal guidelines in effect on this date. OW Municipality of Anchorage DEPARTMENT OF HEALTH & HUMAN SERVICES 825 "L" Street. Anchorage, Alaska 99502.0650 SOILS LOG — PERCOLATION TEST PERFORMED FOR: CL`rr��t& �-� ���, �'1'`,3.�_u•�T��jJ� DATE PER LEGAL DESCRIPTION: t& t /%�N�W �y OWnShip, Range, Section: il ORct1+KS 2 FINE. '_Prjo 3 4- sok �TT1A11F(1-y $Fwo J6 ' Q CAr oy 6;vw A- 6 6 8 9 I I I I ti7W, (�Aot3r> Si�Ty 10 11 12 13 14 15 16 17 18 19 IX.. (L(GH7 SVC? WAS GROUND WATER PG L r4LFX.. ENCOUNTERED? IF YES, AT WHAT DEPTH? Ilt3A.N, mw Y ? ua MaWaNnT otic -41 NNEEMEMEN ®=mm WE® ! i IA t... , oe�,��ssF�a��. 2D-{ IL— JI PERCOLATION RATE ''°lZlrr (mmutwmtf•) PERC HOLE DIAMETER TEST PUN BETWEEN D FT COMMENTS TAU X A 6O h16 PERFORMEY &`Ij '/ ACCORDAI�ppIi,�,D,i irosLl�M'W RR9119M�iO4"OEL 72-M (Rev Poe River, Alaska 97577 CERTIFY THAT THIS TEST WAS PERFORMED IN ON THIS DATE. DATE: KINID ENGINEERING 20441 PTARMIGAN BLVD. EAGLE RIVER, AK 99577-8736 SOILS PERCOLATION TEST Performed for: Lisa Gore Date Performed: 10/11/99 Project•. Sleepy Hollow #1, Block 2, Lot 6 TEST HOLE # 99-2 Depth (Feet) SEE ATTACHED SITE PLAN 1 - Material consistent with T1199-1 2 - Percolation test performed 3- at bottom of trench during installation. 4 - Water monitoring-TH99-1 5- 6- 7- 8- 9- 10- 11- 12- 13- 14- 15- 16- 17- 18- 19 - HOLE PRESOAKED 20- PRIOR TO TEST FOR HOLE LOCATION Was Groundwater encountered? NO What depth? NA Depth to water after monitoring? Dry Date? 6/23/99 Reading Date Gross Time Net Time Depth to Water Net Drop 1 10/11/99 0:00 - 8" - 2 0:10 10 min 310/16" 46/16" 3 ' 0:11 - 8" - 4 0:21 10 min 312/16" 44/16" 5 • 0:22 - 8" - 6 0:32 10 min 315/16" 41/16" 7 0:33 8" - 8 0:43 10 min 41/16" 315/16" 9 • 0:44 8" - 10 0:54 10 min 41/16" 315/16" 11 • 0:55 - 8" - 12 1:05 10 min 41/16" 315/16" • Water Added Percolation Rate 2.54 (min/in) Pere Hole Diameter 6" Test Run Between 6.5 feet and 7.5 feet I, Kenneth M. Duffus, certify that this test was performed in accordance with all State and Municipal guidelines in effect on this date. lqlu-lieipality of Anehorage Department of Health and Human Services 825 "L' Street Rick Mystrom, P.O. Box 196650 Anchorage, Alaska 99519-6650 Mayor http://www.ci.anchorage.ak.us June 7, 2000 Lisa Gore PO Box 671129 Chugiak, AK 99567 Subject: Sleepy Hollow #1, Block 2, Lot 6 Permit # SW990310 PID # 051-501-11 The subject permit 9SW990310 issued by this office for a single family well and/or on- site wastewater system, is due to expire 365 days after it's issuance on Sept. 1, 1999. If this is a well permit and you have drilled the well, a well log must be sent to this office for documentation of the installation and to close the permit. If this is an on-site wastewater system and a licensed Professional Engineer has inspected the installation, the original as -built inspection report must be sent to this office for review, approval and documentation. All inspection reports must be submitted within 30 days of construction completion. A new permit must be obtained from this office for a well and/or on-site wastewater system NOT installed by the expiration date. However a new permit can be issued free of charge for a second year if the application for the renewal is received on or before the date of expiration of the original permit for which a fee was paid. When applying for a new permit after the original permit has expired or for more than a second year, the fees are: $320.00 for an on-site wastewater permit and $120.00 for a well permit. If you have any questions, please call this office at 343-4744. Sincerely, J es Cross, PE Program Manager On-site Services enc: Copy of Permit A Municipality of Anchorage On -Site Water & Wastewater Program (907) 343-7904 RUS CERTIFICATE OF ON-SITE SYSTEMS APPROVAL Parcel I.D. 051-501-11 Expiration Date: 7//F 3 1. GENERAL INFORMATION Complete legal description SLEEPY HOLLOW #1; BLOCK 2, LOT 6 Location (site address) 23741 SLEEPY CIRCLE *CHUGIAK, AK 99567 Current Property owner(s) LISA GORE Day phone C/O AGENT Mailing address 23741 SLEEPY CIRCLE *CHUGIAK. AK 99567 Real Estate Agent SHELDON FINIS Day phone 688-3263 2. TYPE OF DWELLING: Single Family (w/wo ADU) ❑ Duplex ❑ Multiple Dwellings (Single Family and/or Duplex) 3. NUMBER OF BEDROOMS: 4 4. TYPE OF WATER SUPPLY: TYPE OF WASTEWATER DISPOSAL: Individual Well ❑ Individual On-site N Individual Water Storage ❑ Individual Holding tank ❑ Community ClassAr� Well N Community On-site ❑ Public Water System ❑ Public Sewer ❑ Received by: Date: 3 1 COSA to be released to the engineer, unless otherwse requested by the engineer. COSA Fee $q!vU5 Date of Payment 9 3 Receipt Number 0(0gi-,3G COSA# 05CXt 1133 Waiver Fee $ Date of Payment Receipt Number Waiver # 5. STATEMENT OF INSPECTION BY ENGINEER As certified by my seal affixed hereto and as of the validation date shown below, 1 verify that my investigation, based on procedures outlined in the Certificate of On -Site Systems Approval Guidelines for this application, shows that the on-site water supply and/or wastewater disposal system is (are) safe, functional and adequate for the number of bedrooms and type of structure indicated herein. I further verify that based on' the information obtained from the Municipality of Anchorage files and from my investigation and inspection, the on-site water supply and/or wastewater disposal system is(are) in compliance with all applicable Municipal and State codes, ordinances, and regulations in effect at the time of installation. Name of Firm GARNESS ENGINEERING GROUP, Ltd. Address 3701 E. TUDOR ROAD, SUITE 101 * ANCHORAGE, AK 99507 Phone Engineer's Printed Name JEFFREY A. GARNESS, P.E. Date Engineer's Comments: In conducting this evaluation, GEG, LtD. attempted to provide a thorough, conscientious engineering analysis of the system in accordance with ADEC and MOA DSD Guidelines & Regulations. The reported results described the performance of the system under the conditions encountered at the time of the test, and separation distances measured to readily identifiable features. The operational life of all wells and septic systems depend on the local soils condition, groundwater levels that may fluctuate during the year, and the water usage of the family being served by the system. These conditions are outside the control of the evaluator of the system. Satisfactory test results do not guarantee future performance of the system, nor do they guarantee that there are no hidden defects or encroachments. GEG, LTD, can therefore not provide any warranty or future estimate of how long the system will continue to meet the operational requirements of the ADEC or MOA DSD. The content of this report is for the sole benefit of the owner listed above. Any reliance upon or use of this report by any other person or party is not authorized, nor will it confer any legal right whatsoever. 6. DSD SIGNATURE System #1 Approved for 1 _ bedrooms. System #2 Approved for Disapproved. Conditional approval for bedrooms. bedrooms, with the following 337-6179 Y !-7 13 o�F •F.q.. s4�0 . g H T*I I .... .... ..... ..... •.J f e A. Garne a. - E -79 :E-79 3 v� �4e0'frofessl0o' OWSiTE � fOnsWATER ASO a WASTEWATER 0-, Original Certificate Date: y//F, Thl_f Gnicipality or Anchorage D<welop,emt Services Division (DSD) issues Certificates of On -Site Systems Approval (COSA) based only upon the represenatations given in paragraph 5 by an independent professional civil engineer registered in the State of Alaska. The Municipality of Anchorage rs not responsible for errors or omissions in the professional engineer's work. 7. ATTCHMENTS: COSA Checklist _kx_�_ Septic System Ad isory Well Flow Advisoi (Rev. 11105) Nitrate Advisory Arsenic Advisory - Other 1.t t If more than 1 septic system is on the lot: COSA Checklist # of Structure served by this system Certificate of On -Site Systems Approval Checklist Legal Description: SLEEPY HOLLOW #1• BLOCK 2, LOT 6 Parcel ID: 051-501-11 A. WELL DATA rNn t- CIoSS <k � ii SG9 o -s- cr+s=o OEc ��tt-o Well type C If A, B, or C provide PWSID# Well Log (YIN) Date completed Sanitary seal (YIN)_ Wires properlyprotected Total depth ft. Cased to ft. Casing h above ground) in. FROM WELL LOG AT INSPECTION Date of test Static water level ft. ft. Well pr ion g.p.m. 9 - p.m -WATER SAMPLE RESULTS: Coliform '&- colonies/100 ml. Nitrate 3` i6 mg./L. Collected by: GEG, Ltd. Arsenic: NO ug./L. Date of sample: 4/8/13 B. SEPTICIHOLDING TANK DATA Tank Type/Material SEPTIC/STEEL Dateinstalled 10/11/99-3/30/01 Tank size 1250 gal. Number of Compartments E Cleanouts (Y/N) YES Foundation cleanout (Y/N) YES Depression over tank (Y/N) NO High water alarm (Y/N) N/A Date of pumping 5/22/12 Pumper JR'S PUMPING C. ABSORPTION FIELD DATA Date installed 10/11/99-3/30/01 Soil rating .�orft/bdrm) 1_2 Systemtype SHALLOW TRENCH Length 50 ft. Width 5 ft. Gravel below pipe 4.30 ft. Total depth *8.08 ft. Eff. absorption area 500 ft2 Monitoring tube YES Depression over field NO Date of adequacy test **4/3/13 Results (Pass/Fail) PASS For E bedrooms Fluid depth in absorption field before test 0 in. Water added 2600gal. New depth E in. Elapsed Time: E min. Final fluid depth E in. Absorption rate >= 600+ g.p.d. Any rejuvenation treatment (past 12 mo.) (Y/N & type) NONE If yes, give date - **PRE-SOAKED AND TESTED ON SAME DAY D. LIFT STATION Date installed "Pump on" level at in. E. SEPARATION DISTANCES Size in gallons Manhole/Access "Pump off' level 'nigh water alarm level at in. Cycles tested Meets alarm & circuit requirements? SEPARATION DISTANCES FROM WELL ON LOT TO: Septic tankAtft station on lot On adjacent Absorption field on lot On adjacent lots Public sewer main Sewer /septic service line areas manholetcleanout Holding tank Manure/animal excrete storage areas SEPARATION DISTANCES FROM SEPTIC/HOLDING TANK ON LOT TO: '+ Absorption Building foundation 5'+ property line 5field 5'+ Water main 10'+ Water service line *10'+ Surface water 100'+ Wells on adjacent lots 1go, +PVT/200'+PUBLIC SEPARATION DISTANCE FROM ABSORPTION FIELD ON LOTTO: Property line 10'+ Building foundation 10'+ Water main 10'+ P Water service line *10'+ Surface water 100'+ Driveway, paridng/vehide storage 10'+ Curtain drain NONE KNOWN Wells on adjacent Iots100'+PVT/200'+PUBLIC F. COMMENTS *PER KEN DUFFUS P.E. INSPECTION REPORT G. ENGINEER'S CERTIFICATION 1 oeriify that I have determined through field inspections and review of Municipal records that the above systems are in conformance with MOA COSA guidelines in effect on this date. Engineers Printed Name JEFFREY A. GARNESS Date u�v 7 %3 (Rev. 11105)