ON-SITE WASTEWATER DISPOSAL SYSTEM AND/OR WELL INSPECTION REPORT
Permit Number:. SW000304 PID Number: 051-322-26
Larry Witaschek Wastewater System: [] New [] Upgrade
14501 W. Lake Ridae Dr.. Eaale River. AK 99577 ABSORPTION FIELD
LEGAL DESCRIPTION 0.6 ~,o,,~ 9.41
8 4 Lake Ridge Terrace 1.45 F,. 7.93
2.5 ~,.34 ~,.
Well: [] New D Upgrade c.,.~,~u,: 2 ~,. "~"'"'~*':1 I a,,,~.~.~,,,,,:NA
Private 320 ~,. 61 ~ 539 ~ D3034 & F810
Sullivan 8/27/2000 20 ~ Green General 6/27/2001
SEPARATION DISTANCES [] septic [] Holding [] S.T.E.P. [] Other.
~ Septic Abso~tion Lift Holding Public/Private Idan~lack~e~ Capac~¥:
Tank Field Station Tank Sewe~ Line Anchorage Tank 1000
w,, J gS' 100'+ NA NA 25'* Steel 2
~=wo,,, 100'+ 100'+ NA NA ~ / LIFT STATION
c~, ~, NA *50'+ NA NA ~.~ ~.,. &,~o~
*none known. Bedrock separation was vedfied at time of BENCH MARK
construction. Well on lot to septic tank is 100' & 98' to septic tank Door sill
on adjacent lot, which was placed after subject well was ddlled. ~ ~'"~'
100
Engineer's Stamp
~,. ~.~ ~o.. *** ·. o,,.o ...~ ·
Inspections performed by: KND Engineering Dates: 1" 6/27/2001 ~*~.d, 9~.Lt ~.~'~
Development Services Department Approval ~ ~','~,
Reviewed and approved by: ~ .,~ ~ ~/./, )Z~'" Date: Z/o ;~. ~ o0~, '~'~'C-""*- c~= 7~[~"'
]~'X"X~D ENGINEERING, INC.
20441 PTARMIGAN BLVD.
EAGLE RIVER, AK 99577-8736
(907) 696-6111/FAX (907) 696-8111
April 2, 2002
Municipality of Anchorage
Development Services Department
On-Site Water & Wastewater Program
P.O. Box 196650
Anchorage, AK 99519-6650
RE: Well to Septic Encroachment - Lake Ridge Terrace Block 8, Lots 4 & 5
Gentlemen:
Per MOA Permit Number SW000304, the well on Lake Ridge Terrace Block 8, Lot
4 was drilled as proposed and prior to the septic system upgrade of the adjacent
property-Lake Ridge Terrace Lot 5. Subsequently, the new septic tank on Lot 5
was placed within the required 100 feet setback to the well on Lot 4.
On March 30, 2002 ADEC issued multiple waivers under 18 AAC 72, Wastewater
Disposal Regulations, including a 98 feet horizontal separation distance waiver
between the private water system source well located on Lot 4, Block 8, Lake
Ridge Terrace Subdivision and the septic tank located on Lot 5, Block 8, Lake
Ridge Terrace Subdivision. The owner of Lot 4 has no objection to the issuance
of any ADEC or MOA waivers for the referenced encroachment, however; any
necessary fees to obtain such waivers should be paid by the owner or his agent of
Lot 5.
If you have any questions, please contact me at 696-6111/FAX 696-8111.
Respectfully submitted,
Attachments:
ADEC Documentation
Surveys
As-built System Details/Site Plan
Inspection Report
Well Log
AS-BUILT SYSTEM DETAILS/SITE PLAN Pe~-,,i~ svooo3o4
LAKE RIDGE TERRACE S/D, LDT 4, BLDCK 8 PIG#051-322-26
/ ........ :'~
~- ~ I000 6AL n
/
~.~;~ PREPARED FOR: SCALE' NTS ~ ~
~ ................"%~j ~ LARRY ~ BARBARA W~TASCHEK
EAGLE RIVER, AK 99577
rm[~ s~s ~ ENGINEERING
~--~'%" ~.~ ST~. LANG ~KMD 20441 PTARMIGAN BLVD.
~Z .............. *~: CA~ ~'~: ~/~/0] EAGLE RIVER, AK 99577-8736
~"~ss~o ~ o~ ~: ~ [ ~.~~~~~.~`~.~~~.~~~.~:~~~~...~..~.~~`~.~~~~~...~.~~.~~.~~..~..~.~`~.~~.`..~.~~.~...~~.~~~..~~. .'...'.-..'--.]
~O0049.DWG ~: 00049 ~907~696-6111/F~ (907~696-8111
lO00 GAL
SEPTIC ~ ~
TANK ~ SEVER ROCK
10' UTILITY
EASEMENT
!
/
!
/
!
!
/
!
/
!
!
!
S£P~IC / / '
LEAa -OUTS /
/
//
/
· / /
/
/ I
/ /
/ I
tI
I
' SEPTIC
CLEAN-OUTS
Lot 5
Lot 4
18.425 s.f.
/
/
/
/
/
/
(EX,STOiC)
/
/
/
/
/
/
/
/
/
/
i
Lot 3
/
/
/
/
/
/
/
\/
/
/ /
/ /
/ /
/
/ \
/
IdEA~DER LINE \
1/9/JULY 2000 \
/
/
/
30' UTILITY EASEMENT
.OT PLAN ___ ASBUILT ___ SCAI]I~ =. 30' N~R~D3' Projee@'l,l~.
O.. ~ A~n~nt.~ ;n~ 11500 Dali Avenue, Anchorage, Alaska 99515
. . ~ ~u/] ~-o /o rnone
egmsterea Land ~urveyorsf9071 522-4625 Fax
· '
tchoroge Recording Dlstrlct, Alaska, end ~hot the Improvements situated ~,"'~QTH
ereon ore wlthln the property lines and do not encroach onto the property ~..
IJocent Ihereto. that no Improvements on the property lying adjacent thereto
~crooch on the lu~eyed premises end Ihot Ihere ore no roadways, tronsmlsslon~
· OWNEROF LAND
· TAXJIi~EI~IFICATIO N
T'
I- wsl[.~ted at,
Oete of Iss~
· -" ~fter. hm. I~Jmpl~g. gpm
ATTENTION: It Is the ~
of Ar~chomge: Depa~n
.D~: .t'~.. nt of Envl~
~lponstbillty of the property owner to aubmR a ~ the well log to the proper authority. Munldl~
sn! of Health & Human Sen, Ices and/~ Depaflmen{ f Environmental Conse~.ation. MatSu Bomu
nental Conservatk~n.
DEPT. OF ENVIRONMENTAL CONSERVATION
DIVISION OF ENVIRONMENTAL IIEALTH
DRINKING WATER and '~VASTEWATER PROGRAM
555 CORDOVA STREET
ANCIIORAGE, AK 99501
http://~v~vw.st at e.ak. us/d ec/h ome/ht m
TONYKNOWLES, GOVERNOR
Telephone: (907) 269-7696
Fax: (907) 269-7650
March 30, 2002
Dee High, P.E..
DHI Consulting Engineers
800 E. Dimond Blvd., Suite 3-545
Anchorage, Alaska 99515
Subject:
Lots 4, 5, and 6A, Block 8, Lake Ridge Terrace Subdivision; Wastewater
Disposal System Waiver Request, ADEC Project Number 0121-WW-241-822;
Review
Dear Mr. High:
I have completed my review ofthe'submitted information and the Department's file on the
above-reference facility in regards to the requested separation distance waivers.. Based on this
review, I believe that.the requested waivers are reasonable.
Due to the existing soil types, low nitrate levels, lack of. bacteria~ the great depth 0fthe soume
wells in the area, changes in State regulations that impact the requested separ~ition distances, and
all the information that has been collected for similar separation distance waNers in this area, the'
requested waivers appear to be reasonable. Therefore, in accordance with the'Wastewater
Disposal Regulations [18 AAC 72], the following waivers are granted:
The horizontal separation distance between the Class C public water system source
well and the complete wastewater disposal system located on Lot 5, Block 8, Lake
Ridge Terrace Subdivision serving a duplex has been waived from 150 feet to 98 feet.
The Department has no objection to the following waivers under 18 AAC 72, Wastewater
Disposal Regulations:
· The horizontal separation distance between the private water system source well
located on Lot 6A, Block 8, Lake Ridge Terrace Subdivision and the septic tank
located on Lot 5, Block 8, Lake Ridge Terrace Subdivision from 100 feet to 98 feet.
· The horizontal separation distance between the private water system source well
located on Lot 6A, Block 8, Lake Ridge Terrace Subdivision and the soil absorption
system located on Lot 5, Block 8, Lake Ridge Terrace Subdivision from I00 feet to
82 feet.
· The horizontal separation distance between the private water system source well
located on Lot 4, Block 8, Lake Ridge Terrace Subdivision and the septic tank
located on Lot 5, Block 8, Lake Ridge Terrace Subdivision from 100 feet to 98 feet.
Dee High Page 2 03/30/02
The above noted distances were taken from your submittal. If the proposed wastewater disposal
system located on Lot 5, Block 8, Lake Ridge Terrace Subdivision fails or needs to be upgraded,
this waiver becomes invalid. If the n~w system fails or needs to be upgraded, additional
treatment to the waste stream will be required.
With the change in both in the State Drinking Water and Wastewater Disposal Regulations, it is
hard to determine if the water system serving Lot 5, Block 8, Lake Ridge Terrace Subdivision is
truly a Class C public water system. Due to all the concem over separation distances, I issued
the requested separation distance waivers as ifthe existing water system is a Class C public
water system. As a result, the submitted Class C public water system registration form will be
processed in the same manner.
The enclosed copy of the signed Class C public water system registration form constitutes final
operation approval of the existing public water system. The Public Water System Identification
Number assigned to this public water system is 218658. Please make sure that this number is
placed on all water test requests sent to an approve water testing lab. The use of this number will
ensure that the test results will be properly credited to this public water system. I recommend
yearly testing for total coliform bacteria and nitrates.
These waivers and approvals do not imply the granting of any additional authorizations, nor
obligate any local, state, or federal i'egulatory body to grant required authorizations.
Thank you for your cooperation with this office. If you have any.questions, please do not
hesitate to contact me.
Keven K Kleweno, P.E.
Environmental Engineer
Enclosures: As Noted
ce: Jim Cross, P.E., MOA, w/o Ene.
[,HI ".nsul%ln9 £n~lneere
STATE OF ALASKA
DEPAKTMENT 0.~ ENVIRONMENTAL CONSERVATION
INVENTORY AND SOURCE ILEGISTP, ATION FORM
FOR
CLASS C PUBLIC WATER SYSTEM
'"¢7 ~4~ 1385 P.02
A. I, Public Water System Name nnd Location:
· Legnlde~ctlption of property:
Number of'people served daily:
'Number of servlce connections:
Public Wule~'Syslem Owner:.
Ow~c*: Address:
OwnerPhone: /° ¥'dZ" ~tt3' ~87~
2. R,..~gked Check List: . . .
~ $'75.00 reglstratton fee as roqutrcd by 1 g AAC 80.1910.
1-~ 'Results of nitrate mad cnllfo}-m water samples do not exceed the MCL set at I g AAC 80300.
(e~tach repo ,d~ from certified laboratory)
~ Source wale' protection requkements o[' l ~ AAC $0.01 $ have been
(see section B. page 2 for details)
1~ M~nimum separation distance requh'ements of 18 AAC g0.020 have been met.
(see sccdon B. page 2 ['or details)
[] Cross-connection provLsions of' 18 AAC 80.025 have been met.
(see section B. page :2 for details)
Public Water System Source: :
(cb*'clc yes_.or no)
YES "~_..~
Well depth is less than 30 feet to t~e fu-st Opening for water collection.
Well Is located less than 50 horizontal feet to a surface water source.
Source u~es an lmqltradon galle~, spring, raln catchment, er Surface water.
Sotu~e requh-e~ tre~mcnt to meet an MCL set at 18 AAC 80.300.
If answer YI~S to any of the above Public Water System Source, then complete section C. on page
~or De,pnnr~ent Use Only
Tlds water syslem Is hereby granted department api~roval to operate, Thc follo~4ng public water system identification
ADEC StaffSignature
DATE
0/99) Page 1
STATE OF ALASKA
DEPARTMENT OF ENVIRONMENTAL CONSERVATION
CONSTRUCEION AND OPERATION CERTIFICATE
FOR
DOMESTIC WASTEWATER DISPOSAL SYSTEMS
APE''~ -~ ol2.1-kJJ,U'-
located in ,~ ~ , Alaska, submitted in accordance with 1 $ AAC T2.210
by j~ H ~ ~ 0 ~t~ ~ I ~ -- D ~ ~ 1~ ~ . ~ ~ ' have been reviewed and aro
['~ approved.
[~ conditionally approved (s~ ~_~ed conditions).
If ~en ~ not ~ ~in ~o y~ nf~e ~pm~l ~, ~ c~ ~ void ~d new pl~ ~d ~fio~ m~
~ mb~ f~ ~ ~d ~pm~l ~fo~ ~
B. APPROVED CHANGE ORDERS
Change (contract order number or descriptive reference)
Apl~roved by Date
C A~PROVALTO OPERATE
Tl~ "APPROVAL TO OPERATE" section must be completed and signed by the Depariment before this system is made available
. for ase.
TI~ cons~ction of thc ~domestic wastewatcr disposal system was complcted
on ~(date). Thc system is hereby granted interim approval to operate for 90 days following the completion
date.
BY ~ DATE
A.s-buil~/record drawings, submitted to the Department, or an inspection by the Deparlment, has confirmed that th~ domestic
wastewater disposal sy~nn was consU'ucted in substantial conformance with the approved plans. The system is h.ereby granted
final provsi to o
2. YeJlow-Symnn File (Complc~ Section C)
3. Pink-Enginees' Muni~Bo~o~gh (C~nplele Section
(Ret 4/9/) ' 4. Cmtde~,od-Munl/Baeough (C~mple~e Section C)
DHI CONSULTING ENGINEERS
Civil · Surveying · Planning
Mr. Bill Rieth
Alaska Department o~ Environmental Conservation
555 Cordova Street
Anchorage, Alaska 99515
October 1.,2., 2000
W.O.: 20~38
RE: Lots 4, 5 & 6A, Block 8, Lake Ridge Terrace
ADEC #0121-WW-241-822
Record Drawings & Adjusted Waiver Distances
Dear Mr. Rieth,
Attached are the Record Drawings and the "Construction and Operation Certificate" for the
replacement septic system on Lot 5. As we discussed this afternoon, we have encroached
on the waiver distances granted in your approval letter of September 5, 2000. The waivers
· were necessary due to a new well being installed on Lot 4 and unstable soil conditions in
the leach field ~rea. I can assure you that we did everything we could to stay within the
approved limits.
The location of the new improvements, as shown on the record drawings, have been
determined based on a field survey completed by our firm; and I believe all the distances are
correct as shown. All distances are computed from the outside of the well casing and have
been rounded downward to the nearest foot.
The items requiring an adjustment to the waivers granted in your letter of September .Sth
are:
1) Septic Tank (Lot 5) to Private well on Lot 4:
2} Septic Tank (Lot 5) to Private well on Lot 6A:
3) Leach Field (Lot 5) to Private Well on Lot 6A:
99.0' No waiver previously requested
98.0' No waiver previously requested
82.0' (Changed from 85')
Mr. Jim Cross (Municipality of Anchorage, Department of Health and Human Services) has
requested that we obtain a letter from ADEC granting the adjustment in the above waiver
so there is no miss understanding for any future lot owners. If you could provide us an
approval letter in addition to the "approval to operate, it would be greatly appreciated.
])[mond Center Tower, 5th Floor · 800 E. Dimond Blvd., Suite 3-545 · Anchorage, Alaska 99515
(907) 344-1385 · Fax 344-1383
If after reviewing the above information, you have any questions, please give me a call.
cc: Mark Rennet (Owner Lot 5)
439dr10o.ltr
DHI co~lJu~t~)nU~S~ n gin e e r ~
Principal
Permi! No. Oi21-ww-24i-822
DHI CONSULTING ENGINEERS
800 E. DIMOND BULV., STE. 3-545
ANCHORAGE, ALASKA 99515
TELEPHONE: 344-1385
Well & On-Site Wastewater Disposal
Lega~ Description: LOT 5 BLOCK 8 LAKE RIDGE TERRACE
Page 2 of 4
W.O. 20438
Date 10/12/00
System
DyP,.LEX." f /"
LAKE
/ ~SET BACK
CAL. SEFTIC'
CLASS 'C' .'
.30' U.G. UTILITY
/
/
/
/
I WiLL i:~O . ..: E OF' W.~TTER
I ' ~ :;;' 7
~ / 2 "-'-'--r.---~
I / % / /1 00'
I LOT Sa ./.
?
/ SCALE: 1" ,= 30'
LEGEND ....
· CLEAN OUT-PROPOSED-INSTALLED THIS PROJECT /
~UT~UN~ER GROUND TELEPHONE-EXISTING ~ ~ ,~O.~.~. ·
~,~'T RECORD DRAWING \! I
STATE OF ALASKA
DEPARTMENT OF ENVIRONMENTAL CONSEKVAT1ON
CONSTRUCTION AND OPERATION CERTIFICATE
FOK
DOMESTIC WASTEWATER DISPOSAL SYSTEMS
<' -: £ .
A. APPROVAL TO CONSTRUCT
Plans for the conslruction or modification of
..... . ~ ,~./. ,:~ ~. ~c '"7',,
[--] approved.
[] conditionally approved (se~ a~ached conditions).
.% / f"~ ['~...,.~- -
BY
If construction has not started witign two yea~ of the approval date, ~hls cergficate is void and new plans and specifications mast
be mbmitted for review and approval before consiruction.
IL APPROVED CHANGE ORDERS
Approved by
Date
Ch~(~n~a~o~numb~d~ve~f~nce)
Waiver:/Tank on Lot 5 to Well on Lot 4 :
Waiver, Tank on Lot 5 to Well on Lot 6&: 98.0'
Waiver: Field on Lot 5 to Well on 6A: 82'
C. AI~PROVAL TO OPERATE
~ "APPROVAL TO OPERATE' section must be completed and signed by ~he l~parlment before this system is made avail~bl¢
f~ use.
Tl~ conz~uction of the domestic wasiewater disposal system was con, pitted
on .(date). The system is hereby granted intedm approval to operate for 90 days following thc completion date.
BY T1TL~ DAre
A~built/record drawings, submitted to the Department, or an inspection by the DepatUnent, has confirmed that the domegic
wu-tewater disposal system wns constructed in substantial conformance with the npproved plans. The system is hereby gra~ted
flaal approval to operate.
D/slfibmion:
I. ~Nhil~-Engir, e~ (Comple~ 5ecli0~ C)
2. yellow-Sysmn File (Complete S~.ion C)
3. Pi~k-F. nsine~' Muni/BomuSh (C~n~e~
4. Gold~m'od-Munl/Bm'ouO (Cont plet~ ~ C')
~ $lnte of Alisa,- ~
{ [~G~ ) D£PARI~Eh~r O~ J~N~ROZ~I~m'AL CONStKYA'r~oN
. ~ ." .P.O. ~.x O, J.,mu, Ahsk~ ,S 1 ,., S~. .
CERTIFICAT/ON OF CONSTrUCT/ON
FOR ..
DOMESTIC WASTEWATER SYSTEMS
P.O1
Sta'te of Alaska
DEPARTMENT OF ENVIRONMENTAL CONSERVATION
P.O. Box O, Juneau, Alaska 99811.1800
CERTIFICATION OF CONSTRUCTION
FOR
DOMESTIC WASTEWATER SYSTEMS
InsU~uc(iom:
Within ~0 day~ after the construct;on, installation, er modification of a project ia completed, thc owner, thc contractor(O
respons~le for constructing the project, and a registered engineer responsible for construction inspection, complete and sign
thi~ form declaring that the project was constructed in accordance with the most recent Department-approved plans, or in
accordance with the attached as-bu~It drawings.
2. If a project is being completed in phased constru~on, a map shall be attached showing that portion of the project being
declared completed on the date stated in thc Owner's Section. Completion of each phase of a project must be declared as
it is completed. Addltinnal Certification of Co~tructlon forms are available from any Department of Env~runmcntal
Conservation office.
Plea. se type or print. ~rcept for signature:
SEL-I ION A Owner's Section
Name and brief description of project .Lo~ 5
Wastewater upgrade
Name ofowncr Mark Rennet
P.O. Box 884
~a~-h~,~ Alaska 99559 ',, ,,. Dhte ~project _C~'_~p)etedl 0 / 1 2 / 0 0
~ty State Zip . ·, ... .-,,-,,., ·
",- ..... ~' .'3.!
I certlfythat I am the owner of the above-referenced project. I further certify that this proj~qvas c~nstructed in accordance with
the iate~t pinn,~ submitted to and approved by the Alaska Department of Environmental Conservation (ADEC'), or in accordance with
thc atta&ed as-built drawings. 1 understand that I may be required to take remedial measures lo correct any construction which was
completed without prior ADEC approval, which departs from the approved plans, and which is found to be inconsistent with the
aplplical~e requirements of ADEC wastewater disposal regulations (18 AAC 72).
Signature of. Owner (please sign i~ ink)
Date
Page 1 of 2
SECTION' B Contractor's Section
I certify that I (or an individual under my direct super~inn) have conducted an inspection of thc project rcfercnced in Section
or portions of the project which I had the responsibility for constructing, and that to the best of my knowledge and information, th,
project, or those portions, was or were constructed in accordance with the latest plans submitted to and approved by the Alask~
Department of Environmental Conservation, or in accordance with the attached as-built ~awings;.] .
Eagle Mountain Excavating, Inc. ~'~ ~tO.t ~..o0.
Typed or Printed Name of Contractor Signature of ContrActor (please ..... ~gn la ink) Date
For multiple contractors, if applicable:
Typed or Printed Name of Contractor
Typed or Printed Name of Contractor
Signature of Contractor (please sign/n ink)
Signature of Contractor (please sign in ink)
Date
Date
SECTION C Engineer's Section
I certify that I (or an individual under my direct superx4sinn) have conducted an inspection of the ubov~ referenced project, and the
to the best of my knowledge and information, the project was constructed in accor~nce with: (check onc of thc foliow~ng)
[] the latest plans submitted to and appr.oved by thc Alaska Departmcnt of Environmental Conservation
bate /
Page 2 of 2
~ic,'(
Municipality of knchoi-agc
Department of Health and Human Services
825 "L" Street
P.O. Box 196650 Anchorage, Alaska 99519-6650
343-4744
November 12, 1996
John E & Youn B Matich
16423 Old Glenn Highway
Chugiak, Alaska 99567 6907
Subject: Lot 4 Block 8 Lake Ridge Terrace Subdivision
Permit #SW950383, PID #051-322-26
The subject permit, issued November 9, 1995 by this office for a
single family well and/or on-site wastewater system, has
expired as of November 9, 1996.
A new permit must be obtained from this office for a well
and/or on-site wastewater system NOT installed by the
expiration date.
If you have drilled the well, a well log must be sent to
this office for documentation of the installation and to
close the permit.
If a licensed Professional Engineer has inspected the
installation of the on-site wastewater system, the original
as-built inspection report must be sent to this office for
review, approval and documentation. Ail inspection reports
must be submitted within 30 days of construction completion.
When applying for a new permit, the fees are: $320.00 for an
on-site wastewater permit; $120.00 for a well permit and
$440.00 for a combined on-site wastewater and well permit.
If you have any questions, please call this office at 343-4744.
Sincerely, ~.~
Ja~e$ Cross, P.E.
?r~gram Manager
On-site Services
enc: Copy of Permit
cc: Eagle River Engineering Services
PAGE
MUNICIPALITY OF ANCHORAGE
DEPARTMENT OF HEALTH AND HUMAN SERVICES
P.O. BOX 196650, 825 "L" STREET, ROOM 502
ANCHORAGE, ALASKA 99519-6650
ON-SITE WELL AND WASTEWATER DISPOSAL SYSTEM PERMIT
PERMIT NUMBER:SW950383
DESIGN ENGINEER:EAGLE RIVER ENGINEERING SERVICES
OWNER NAME:MATIGH JOHN E & YOUN B
OWNER ADDRESS:14501 W LAKE RIDGE DR
EAGLE RIVER, AK. 99577
PARCEL ID:05132226
1 OF
DATE ISSUED:il/09/95
EXPIRATION DATE:il/09/96
LEGAL DESCRIPTION:
LAKE RIDGE TERRACE BLK
8 LT 4
LOT SIZE: 18425 (SQ. FT.)
NUMBER OF BEDROOMS: 2 THIS PERMIT: 2
THIS PERMIT IS FOR THE CONSTRUCTION OF:
DISPOSAL FIELD /SEPTIC TANK / WELL SYSTEM
ALL CONSTRUCTION MUST BE IN ACCORDANCE WITH:
1. THE ATTACHED APPROVED DESIGN.
2. ALL REQUIREMENTS SPECIFIED IN ANCHORAGE MUNICIPAL CODE CHAPTERS
15.55 AND 15.65 AND THE STATE OF ALASKA WASTEWATER DISPOSAL
REGULATIONS (18AAC72) AND DRINKING WATER REGULATIONS (iSAACS0) .
3. THE ENGINEER MUST NOTIFY DHHS AT LEAST 2 HOURS
PRIOR TO EACH INSPECTION. PROVIDE NOTIFICATION BY
CALLING 343-4744 ( 24 HOURS ) (NOT REQUIRED FOR WELL ONLY PERMIT)
4. FROM OCTOBER 15 TO APRIL 15 A SUBSURFACE SOIL
ABSORPTION SYSTEM UNDER CONSTRUCTION DURING FREEZING
WEATHER MUST BE EITHER:
A. OPENED AND CLOSED ON THE SAME DAY
B. COVERED, SEALED AND HEATED TO PREVENT FREEZING
5. THE FOLLOWING SPECIAL PROVISIONS.
SPECIAL PROVISIONS:
BENT UY;AUE~ ~NGHg~A~
TONY
DEPT. 41)F ENVIROPMMENTAL CONSEIiVATION
ANCHO :{AGE/WESTERN PUBLIC SERVICE AREA
555 CO :~DOVA STREET
ANCHO ~,GE, ALASKA 99501
Noveml:.3r 9, 1995
Louis Bi.tera
Eagle River Engineering Services
P.O. Bc~: 773294
Eagle River, Alaska 99577
SUBJE(:T:
RECEIVED
NOV 9 1995
Municipality of Anchorage
Dept, H,ealth & Human Service~
Lakeddge Terr. Lot 4, BI. 8, Separation Distance Waiver
982t-WV-292-018
(907) 269-750'5
Dear Mr Butem:
We race red the above request dated Ob-'tober 19, 1995. Included were a well waiver
data eh{~et, system plan review checklist, tope map, well profiles, site plan, soils logs,
well Iog.% water analysis, and septic system installation.specifications. Your client, John
.Mattich,. 3aid the waiver fee.of $230 from I~voice No. 203137 with his check no. 85.
The reqL est is to reduce the required 150' separation distance from an unapproved
Class C ~vell on Lot 5 to the southwest to 140'. Because ~ physical and separation
distance cohstraints, the requested location for the applicant's septic drainfield is the
only one available.
We have! ~arefully reviewed all of the above information and approve, per 18 AAC
· 72.0150: ) and t 8 AAC 80.030, the waiver reducing the distance between the Class C
well end your proposed drainfleld Eom 150 feet to 140 f~et. Your client should be
aware that there is a chance that the dratnfield will contaminate his proposed well, even
though J'e meets the separation distance required of 100'. This is because of local
terrain, ~oils, and water table, He may want to test. his well for contamination on a
regular I:asis. This approval is for existing conditions; any change in land use on Lots 4
or 5 ma!, require another waiver application.
This approval does not imply the granting of any additional authorizations nor obligate
any Ioc~, state, or federal regulatory body to grant required authorizations. We
apprecl=ite your cooperaU=n with the Department. Please contact me if you have
questior~s on arty of the foregoing.
Cordiall!,,
Environr ~ental Engineer
cc: ' J~:,hn Mattich, Owner
Louis Butera, P.E.
Registered Civil Engineer
October 4, 1995
Jim Cross, P.E.
Manager, On-Site Services
Municipality of Anchorage
P.O. Box 196650
Anchorage, AK 99519
Re: Lake Ridge Terrace #1 Lot 4, Blk 8
Narrative & Permit Application
Dear Mr. Cross:
The proposed well and septic system will have very limited impact on adjacent properties for the
following reasons:
The surrounding lots are developed. Their reserve area is limited by their own
well radius.
2. Immediate neighboring septic systems are all +28' distance.
o
Reserve space is provided for a two bedroom facility. The reserve area will be
constructed at this time and connected to a diversion valve.
4. Drainage will not be affected and is not a major consideration in our design.
Due to the limited area outside the 100' lake setback, we are placing the reserve leachfield area
within 10' of the driveway and providing additional insulation in this area, see specification C.6.
The primary leachfield is located 142' from an unregistered class "C" well. The ADEC has
granted a waiver to allow the separation distance, recognizing that the Lot 5 septic system
encroaches on its own well. If you have any questions please call our office at 694-5195.
Sincerely,
Louis Butera, P.E.
\G:\WPDOCS\1995\91-037A.NAR
SPECIFICATIONS FOR ON-SITE SEPTIC SYSTEM
LEGAL:
Lake Ridge Terrace #1 Lot 4 Blk 8
10/04/95
A. GE~RAL
1. The well and septic plan is for a two bedroom single family residence only.
2. The drawing and or site plan shall be a part of this specification.
3. All materials and workmanship shall meet the Anchorage Department of Health
requirements.
4. Al1 soil tests are advisory to the design and are to be verified or modified in the
field by the engineer.
5. All excavations and depths are advisory and are to be verified in the field by the
contractor to meet Municipality of Anchorage requirements.
6. It is the responsibility of the owner to obtain all necessary pemfits or easements
and to locate any adjacent multi-family wells.
7. The excavation is to be exactly in the area shown on the site plan, any deviation
requires engineer approval.
8. It is always recommended that a surveyor locate the nearest lot line position and
the location of any easements.
9. Any remaining open test hole excavations shall be filled.
B. SEPTIC TANK/INTERIOR GRINDER PIJMP
1. A solid handling grinder type pump with basin and controls shall be placed inside
the dwelling where it can be monitored for any leakage.
2. The septic tank shall be placed into the hill to allow gravity feed to the leachfields.
Tank is to be insulated with 2" of burial foam and soil mounded 2' over insulation
and graded away a slope not to exceed 3:1 in any direction.
C. TRENCH
1. The trench is to follow the natural land contour to maintain uniform total depth of
the trench bottom.
2.The bottom of the trench shall be level, plus or minus 1.5".
3.The total depth of the trench excavation is not to exceed 9' at any point.
4.The trench gravel is to be covered with typar fabric material.
5. A combination of 18" soil and 2" extruded board insulation is to be placed over the
leachfield, mounding as necessary. 4" insulation shall be placed over the leachfield
located within 10' of the driveway.
6.A Bull-Run type diversion val~e shall be installed between the two trenches.
7.Flush mount covers over cleanouts located in driveway.
8. The area over the trench is to be finish graded to prevent ponding of surface water
runoff. Area over the trench and tank is to be seeded.
9. The septic tank and leachfield must not be closer than 100' to any existing private
well, 130' to any Class "C" well, or 200 feet to any community well.
RECOMMENDED LEACHFIELD DIMENSIONS:
TOTAL DEPTH = 9' GRAVEL DEPTH = 7.5' under pipe, 2" over pipe
TRENCH LENGTH = 34' TRENCH WIDTH = 3'
SOIL RATING = 0.6 GPD/ft2 BEDROOM CAPACITY = 2
SEPTIC TANK = 1,000 gallons
Twenty-four (24) hours notice required for all inspections.
G:\V~PDOCS\ 1995\91-037A.S PC
EAGLE RIVER
ENGINEERING SERVICES
P,O. Box 773294
EAGLE RIVER, AK 99577
(907) 694.5195
SHEET NO OF
SCALE
.sINGLE:FAMIT~yTWo, BEDROOMIDWELLING:Io/O4/9$ .!:;i i i .......... ...... .... .......... ...... .........
....... :,,, ,,:, .... Percoiation rate = 13.3 min/inch & 23 min/inch ! ! ~:
Requited ~bSorption Area = 300 GPD/ 0.6 = 500 square feet .
LDT 3 /
SEPTIC TANK
PROPOSED 2-34' LEACHFIELDS WITH
DETAIL ssPsi INSULATION WITHIN 10' OF DRIVE
FLUSH MOUNT~ IRON UTILITY COVER UNDER DRIVE
/
1-114-
/
/
· TH2
/
CLASS C WELL
SEPTIC SYSTEM
/
/
/
/
/
h=~'~l "~DNCRETE ]8'X18'
POSED lO00 GAL STEEL
SEPTIC TANK
qDER PUHP :'"
/ / · ~
h
/// ~ ~ x
/ /
/
/' / [] - TEST HOLE
/ / · - MONITOR TUBE
/ o - SEWER CLEANOUT
~ - WELL
/ PROPOSED LEACHFIELD
NO KNOWN CURTAIN DRAINS EASEMENT
WELL/SEPTIC :SITE PLAN
LEGAL: LOT 4, BLOCK 8, LAKE RIDGE TERRACE //1
.OWNER: MATTICH
CONTRACTOR: N/A
JOB # 91-0571 DATE: 10/04/951 SCALE 1" = 40'
EAGLE RIVER ENGINEER/NC SERVICES
A P.O. Box 773294
EAGLE RIVER, Al<. 99577
(907) 694-5195 FAX: (907) 694-3297
PERFORMED FOR:
LEGAL DESCRIPTION:
1
2
3
4
5
6
7
8
9
10,
11
12
13
14
15
16
17
18
19
20
Municipality of Anchorage
DEPARTMENT OF HEALTH & HUMAN SERVICES
825 "L" Street, Anchorage, Alaska 99502-0650
SOILS LOG -- PERCOLATION TEST
~,~,~'~ /.Z/~'~_~ ~?..~,~AL~//Township, Range, Section:
-,,!
SLOPE
SITE PLAN
S
L
IF YES, AT WHAT //~/.,~ pO
DEPTH? ,
E
Depth to Water Alter
Monitoring7 ~Y Dale: ~/"~ &/?/
Gross Net Depth to Net
Reading Date Time Time Water Drop
~o~- ~'1~/9 /
/ /, ,'~ ',q ? /0 ~' ~ la~lb," / ~/1~"
4 ,, ~:1~ IO ~' ~ ~l~u" Izl/~"
G · ,, ~:~s I0 ~' 5 ~1/~" 171/u-
PERCOLATION RATE /--~',.~ (minutes/inch) PERC HOLE DIAMETER
TEST RUN BETWEEN ~Z~ FT AND FT
T/~/ ~r ~.~ L~_~ -ct £
PERFORMED BY: ~"'"~ ~..~, I ~'::-: ' '~' '~': ' ' ::':' CERTIFY THAT THIS TEST WAS PERFORMED IN
PERFORMED FOR:
DEPARTMENT OF HEALTH & HUMAN SERVICES
825 "L" Street, Anchorage, Alaska 99502-0650
SOILS LOG-- PERCOLATION TEST
.
~ ~- g~ ~t DATE PERFORMED: ~/~0 /~
' ~1~ /
sh~p~ ~nge~ Section:
7
8
4
SLOPE ' SITE PLAN
WAS GROUND WATER
ENCOUNTERED?
IF YES. AT WHAT
DEPTH?
Water Alter
11
12
17
18
19
g?
, Gross Net Depth to Nat
Rea, ing Date Time Time Water Drop
PERCOLATION RATE Z.~__~ (minutes/inch) PERC HOLE DIAMETER
TEST RUN BETWEEN ~ FTAND ~ .FT
COMMENTS · ~.l~,er I.oop ~.[;a~ ~o ~ ~ ~ ~ ' ' '
CERTIFY THAT THIS TEST WAS PERFORMED
ACCORDANCE WITH ALL STATE AND MUNICIPAL GUIDELIN~EFFECT ON THIS DATE. DATE:
Municipalityof
Anchorage
OFFICE OF THE MAYOR
February 13, 1992
John Eric Matich
18156 Harbor Point Loop
Eagle River, Alaska 99577
Dear Mr. Matich:
P.O. BOX 196650
ANCHORAGE, ALASKA 99519-6650
(907) 343-4431
TOM FINK,
MA YOR
I am responding to your letter of January 29, 1992. I understand your concerns about the fill
permit process of the U.S. Army Corps of Engineers. In fact, I share some of your same
opinions.
More specifically, I have sought a review of your permit request from municipal departments.
T..e D..~.artm~..t of Econo.mm Development and Plarming have supported your request. ~.~-k,,ey
stated, "The applicant has proven justification for the project based on need and lack of
alternatives due to lot constrictions and septic requirements." This was transmitted through
the State of Alaska on November 14, 1991.
The matter of the waiver has been discussed with the Department of Health and Human
Services. They indicate that the matter is not appropriately before them. They do not issue
waivers or even address them prior to actual design and construction. They do not intend to
issue a waiver under current circumstances.
I hope this information is useful to you.
Tom Fink
DEPT. OF ENVIRONMENTAL CONSERVATION
ANCHORAGE DISTRICT OFFICE
3601 C STREET, SUITE 322
ANCHORAGE, ALASKA 99503
WALTER J. HICKEL, GOVERNOR
RECEIVED
AUG 12 1991
563-6775
August 9, 1991
Mr. Louis Butera, P.E.
Eagle River Engineering Services
P.O. Box 773294
Eagle River, Alaska 99503
Subject: Lot 4, Block 8, Lake Ridge Terrace ~ Separation Distance Waiver between
a Class C Public Water System Source Well and an On-Lot Wastewater
Disposal System, Eagle River, Alaska, ADEC Project Number 9221-WA-004;
Review
Dear Mr. Butera:
This is in response to your submittal, received in this office on April 23, 1991, in which
you requested that the Department either waive the current minimum 150 foot separation
distance between an unapproved Class C Public Water System Source Well on Lot 5,
Block 8, and the on-lot soil absorption system on Lot 4, Block 5 or take enforcement
actions. I have reviewed the submitted information and find that I can not agree with your
conclusion that the requested waiver should be granted. However, I do believe that
some type of action can be taken on resolving this problem.
Even if the Class C Public Water System had been approved by the Department, your
submittal did not provide sufficient information to justify a waiver under 18 AAC 80.020 of
the Drinking Water Regulations and 18 AAC 72.035 of the Wastewater Disposal
Regulations. As noted in your letter, Lot 6A, Block 8 had previously received a waiver.
However, our records indicate that Mr. Donald Krafft, owner of Lot 6A, Block 8, did not
submit the information requested by the Department in it's August 18, 1979 letter. That
being so the waiver, issued by the Department March 2, 1990, may be invalid.
I believe it is appropriate to grant a temporary waiver for Lot 4, Block 8, which will
terminate when the water system source well located on Lot 5, Block 8 Lake Ridge
Terrace #1 is either determined to be a private water system or approved as a Class C
Public Water System. The waiver is being granted in accordance with the Wastewater
Disposal and Drinking Water Regulations. The separation distance between the
unapproved Class C Public Water System Source Well on Lot 5, Block 8 and the new
wastewater disposal system on Lot 4, Block 8 is hereby waived from the minimum 150
feet to 130 feet.
~.~ printed on recycled paper
Mr. Louis Butera, P.E.
August 9, 1991
Page 2
The Department will investigate the situation further and contact the owner/operator of the
Public Water System on Lot 5, Block 8. A permanent waiver will not be necessary if the
Department finds that the system serves a single-family residence. However, if the
investigation reveals that the system should be classified as a Class C Public Water
System, the owners of Lots 4 and 6A, Block 8 may need to submit additional information
to obtain the required waivers.
Thank you for your cooperation with this Department. If you have any questions, please
do not hesitate to contact me.
Keven K. Kleweno
Environmental Engineer
cc: John Smith, DHHS
KKK/pf