HomeMy WebLinkAboutSCIMITAR #1 BLK 2 LT 13Block 2
Lot 13
#051-132-21
Municipality of Anchorage -"'
Development Services Depadment ~1
Building Safety Division ~,~
On-Site Water and Wastewater Program, 4700 S. Btagaw St.
P.O. BoxI96650 Anchorage, AK 99519-6650 Page t °f3
wvM.ci.anchorage.ak.us (907) 343-7904
ON-SITE WASTEWATE" DISPOSAL SYSTEM AND/OR WELL INSPECTION REPORT
Permit Number: ~[~.'3OJO J ~O PlDNumber.
"'"'Po~I 8~-,/",,~l~'0/~ WastewaterSystem: C~New DUpgrade
pOBol~ ~'7l'~ V7 Z/')M~4~'../~Kq~5~'7 ABSORPTION FIELD
LEGAL DESCRIPTION · ~.~, ¢... ~,
e--,,~ ':13 S,,,-,f',*r~l'"'"-'~:-~..~''--'': q',.
~ ~,~ ~s..-n,} c.,.~e~ TANK
SEPARATION DISTANCES ~sept~ Dtlolding DS.T.E.P.
~ Septic Abso~tion LiE HoMing Pubfi~ah M~
'-'""' I~ I~ X / LIFT STATION
"~' UO ~ BENCH MARK
S & S ENGINEERING
Inspections performed by: 170~ E~l* Rl.r Lo~ Roid, N~s. 1~ ~- ~--
~....-..~..*.-~., ~ ~-~O.Ol
DevelOpm~t Se~i~s Department Approval
Reviewed and approved by: Date:
PERMIT NO.SW010180 PAGE 2 OF'
MuniciDoti% oF' .~,n~ h o. F o,.cj?'
DEPARTMENT OF HEA~_TH ANU HUIVlAN SERVICES
ENVIRONMENTAL SERVICES DIVISION
P.B. Box 196650 ®A~cho,"'o, ge, Atc, skc, 99519-6650®Tetephone, 343-4744
ON-SITE WASTEWATER DISPOSAL SYSTEM AND/OR WELL INSPECTION REPORT
LECAL LOT 15t BLOCK 2, SCIMITAR #1
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/ I
WELL RADIUS
,/
·
~..' ,.~' .,
{\\,..~\\\1I
~- \\ /
/
DBL1 ·
TH
MT
LOT 14
P.LD. NO. 051--132--21
LOT 12
.:02
ROBERT ~ COWAN
CE .8801
P£R~rT No. SW010180 PAC£ 5 Or 3
Municip. (xiit_y__oF .A.m_c h.o.r' g g.e..
DEPARTMENT OF HEALTHAND HUP1AN SERVICES
ENVIRONMENTAL SERVICES DIVISION
P.n. Box 196650 eAnchor'age, Alaska 9951g-6650eTelephone: 343-4744
ON-SITE WASTEWATER DISPOSAL SYSTEH AND/OR WELL INSPECTION REPORT
L£CAL LOT 15, BLOCK 2, SCIMITAR #1
P.I.D. NO. 051--132--21
ST1
FINA~GRADE-~
S~.~- 95.6'
~- -.~:~-~-~-~-~-~-~' NEW 1250 '
91.7'" J GALLON
~SEPTIC TANK
CO!
C02
._.CO1 = 94.2'
C02 96.2'
~X'-FINAL GRADE
..~C01 = 90.6'
C02 90.6'
A B C
:'CO 1 2.0' - 1 8.5'
ST1 2,.5.0' - 16.0'
5T2 50.5' 60.5' -
3BL1 56.5' 61.5' -
3BL2 58.5' 61.5' -
301 55.5' 85.5' -
VlT1 55.0' 85.0' -
302 - 29.5' 27.5'
S & S Engineering
17034 North Eagle River loop road
Eagle River, AK 99577
Attention: Robert C Cowan P.E.
Paul L Bergeron
Po box 67-1347
Chugi~k, AK 99567
To whom it may concern:
I installed the septic system at my property located at lot 13, block 2 of Scimitar Sub. #2.
It was installed per the specifications furnished by Sx'S Engineering, and codes required
by the Municipality of Anchorage. Inspections were completed by S&S Engineering,
~th the materials, placing, quantities, and workmanship, meeting the r~quiremen~s of the
Inspector.
Thank you.
Paul L. Bergeron
March 14, 2002
ROBERT C. COWAN. P.E.
CML ENGINEERS
(907) 694-2979
FAX (907) 694-121
Municipality of Anchorage
Department of Ilealth and Human Services
P.O. Box 196650
Anchbrage, AK 99519
REFERENCE: Lot 13; Block 2; Scimitar #1
Request that you issue a waiver for the horizontal separation distance between the
leachfield and the 25% grade embankment on the referenced property. A standard
separation distance orS0 feet was not feasible due to insufficient fill available on the
property. The cost to import sufficient fill to extend the bank was prohibitive.
The current distance between the leachfield and the embankment is 35+ feet. We believe
the granting of this waiver will not adversely affect public health, adjacent property
wells or septic systems.
If you require additional information, please contact us.
Sincerely,
Robert C. Cowan, P.E.
RCC/ts/waivcrs/bergcron.doc
17034 NORTH EAGLE RfVER LOOP * SUITE 204 · EAGLE RIVER, ALASKA 99577
MUNICIPALITY OF ANCHORAGE
Development Services Department
On-Site Water & Wastewater Program
4700 South Bragaw Street
P.O. Box 196650, Anchorage. AK 99519-6650
(907) 343-7904
ON-SITE WASTEWATER DISPOSAL SYSTEM I WATER SUPPLY PERMIT
Initial
Date Issued: Jun 11,2001
Expiration Date: Jun 11, 2002
Permit Number: SW010180
Legal Description: SCIMITAR#1 BLK 2 LT 13
Design Engineer: 0003 S & S Engineering
Owner Name: PAUL BERGERON
Owner Address: NHN TULWAR DRIVE
ANCHORAGE, AK 99567-
Parcel ID: 051-132-21
Site Address:
Lot Size: 40090 SQ. FT.
Total Bedrooms: 4 Permit Bedrooms: 4
This permit is for the construction of:
[] Disposal Field [] Septic Tank [] Holding Tank [] Privy
[] Private Well [] Water Storage
All construction must be in accordance with:
1. The attached approved design.
2. All requirements specified in Anchorage Municipal Code Chapters 15.55 and 15.65 and the State of Alaska
Wastewater Disposal Regulations ( 18AAC72 ) and Ddnking Water Regulations ( 18AAC80 ).
3. The engineer must notify DSD at least 2 hours prior to each inspection. Provide notification by calling
(907) 343-7904 ( 24 hours ). ( Not required for a Water Supply Permit only ).
4. From October 15 to April 15, a subsurface soil absorption system under construction during freezing weather
must be either: A. Open and closed on the same day.
B. Covered, sealed, and heated to prevent freezing.
Date: ,O /
Date: ~
Municipality of Anchorage
Development Services Department
Building Safety Division
On-Site Water and Wastewater Program
4700 South Rragaw St.
P.O. Box 196650 /~chorage, AK 99519-6650
www.cl.anchorage.ak.us
(907) 343-7904
ON-SITE SEWER/VVELL PERMIT APPLICATION
FOR A SINGLE FAMILY DWELLING
Parcel I.D.
Permit Number SW O I0 150
Pro.e owner(s) 9, .l
Uailing address (1) p.o. Go x ~o7
~address(2)NH~ T~L ~8~ PRIuE
Legal description (Lot, Block & Sub'd.) ~ o~
Legal description (Section, Township & Range)
Lot Size
40,
THIS APPLICATION IS FOR:
Day phone ~ ~'~ ' ~-~ ~'~'
Zip Code ct ~j 5" (, '7
Number of Bedrooms
Sewer Only
Sewer and Well
Sewer Upgrade
THIS PROPERTY CONTAINS:
Hot Tub
Swimming Pool
Therapy Pool
Well Only
Water Storage
Jacuzzi
Water Softening Unit
[]
I certify that the above information is correct. I further certify that this application is being made for a
Single Family Dwelling and is in accordance with applicable Municipal Codes.
$ & $ ENGINEERING
(Signature of properly owner or authorized agent)
Permit Fees:
Date of Payment:
Receipt Number:
(Rev. 12/00)
C'/,, /o /
0O3* Itl
Waiver Fees:
Date of Payment:
Receipt Number:
May30, 2001
ROBERT C, COWAN, P.E.
CML ENGINEERS
(907) 694-2979
FAX (907) 694-1211
MUNICIPALITY OF ANCHORAGE
Development Services Department
P.O. Box 196650
Anchorage, AK. 99519
REFERENCE: Lot 13, Block 2, Scimitar S/D
It is request~ that you bsue a pe~it to install a septic syste~o se~e the proposed 4
bedroom dwelling on the referenced prope~. P~r~
A test hole ~ excavated ~d a ~reo]ation test ~ffo~cd.
· c test bole is located on ~c a~chcd site pl~. At ~c time of excavation 5/18/01 no
~tcr w~ fo~d. ARcr monitoring, ~o~d water w~ not
We do not anticipate any adverse effects on neighboring wells, septic systems, reserve
areas or drainage patterns by the installation of the proposed septic system. The
construction of this system will not prevent any future development on any of the adjacent
properties.
If you require additional information, please contact us.
Sincerely,
Robert C. Cowan, P.E.
ccro'xi
Enclosure
17034 NORTH EAGLE RIVGR LOOP · SUITE 204 · EAGLE RIVER ALASKA 99577
~ ~'~ LOT 1:3, BLOCK 2, SCIMITAR S/D
~'~ "-J.J- I ,.c.c. I ~-3o-o, I , oF, .~,~ ^-...:.:,:.~.
eoo/~.~ = ~oo ~O.~T. ~ ~./ / ~
u~.~..*~.~.s. / I I'1' /I~ .~ / / ~
7.0' D~P / / ./ ~ /
~.O~FF~TIVE // / ~/ ~ /
/ / I
LOT 3 ~,,' / ~ / X /
/' / / / (~ ~ ~PRCPOS[D 1250 GALLON
/' / / / /~ ~WA' ER STORAGE TANK
/ / I
LOT 14
DEPARTMENT OF HEALTH & HUMAN SERVICES
825 "L" Street, Anchorage, Alaska 99502-0650
SOILS LOG -- PERCOLATION TEST
7-
8-
9-
It
13-
14-
15-
17-
18-
19-
:20-
WAS GROUND WATER
ENCOUNTERED? ~V O
SLOPE SITE PLAN
IF YES, AT WHAT
DEPTN?
Oeplh Io V/lief Alter
Idoailofiflo? Oal~
//Time Time Water Drop
' / /o /~ / ~/~
~0 /0 I~-'~
-0 (0'
/ o /o IZ*/~"~
/ ~ ~ o I ~1
COMMENTS
PERCOLATION RATE __ (m,nutes/,ncl~) PERC HOLE DIAMETER
1EST RUN BETWEEN ~ FTAND ~/~ FT
17034 E~g,e Kivar Lq Road No. 2G4
ACCOR DANCE Wl~f4el'~k~il~l~'AL G UIDELIN E S IN EEF E CT ON THIS DATE DATE:
72.~ (R~. 4,~)
ROBERT C. COWAN, P.E.
CML ENGINEERS
(907) 694-2979
FAX (907) 694-1211
ON-SITE WASTEWATER DISPOSAL SYSTEM
CONSTRUCTION PRACTICES
and
MATERIAL SPECIFICATIONS
REFERENCE: Lot 13, Block2, Scimitar Subdivision
May 30, 2001
GENERAL:
The scope of this project includes the installation of a 1250 gallon minimum
septic tank and a new trench to serve the proposed four bedroom residence
located on the referenced property.
Construction shall be in accordance with the approved site plan and design
drawings, Municipal permit with any special provisions or conditions, and all
applicable State and Municipal Wastewater Disposal Regulations.
The contractor shall be responsible for obtaining any necessary underground
utility locates.
Unless specifically agreed otherwise, the property owner shall be responsible
for final grading areas subsequently depressed from soil settling.
Contractors installing wastewater disposal systems must be certified by the
Municipal Health Department for system installations. Owners installing their
own systems must also receive prior approval from the Municipal Health
Department.
SEPTIC TANK INSTALLATION:
I. A septic tank is to be constructed by a certified septic tank manufacturer.
Construction shall include two 4" clcanouts for pumping access.
2. The septic tank shall be sufficiently bedded to prevent setding or shifting of
the tank.
17034 NORTH EAGLE RIVER LOOP · SUITE 204 ,, EAGLE RNER, ALASKA 99577
Page 2
Lot 13, Block 2, Scimitar Subdlvlllon
May 30, 2001
All standpipes on the septic tank shall extend a minimum of 12 inches above final grade.
Septic tanks installed with less than 4 ft. of cover shall be insulated.
A foundation cleanout shall be installed one to four feet from the building foundation. In
the line between the tank and the leachfield there shall be two adjacent cleanouts (unless
an effluent pumping system exists within the septic tank). These cleanouts shall be
located on undisturbed soil not more than 10 ft. from the tank. The first cleanout, in line,
shall be to clean toward the leachfield. The second cleanout shall be to clean toward the
septic tank.
Final grading over thc septic tank shall be such that a positive slope exists away from the
septic tank.
ABSORPTION TRENCH/DRAINFIELD INSTALLATION:
Excavate the proposed trench to the dimensions shown on the design. The bottom of the
excavation shall be within 2 inches of level. If the sidewalls of the excavation become
smeared, they must be raked or scratched (rafted-up) before gravel (sewer rock)
placement.
Once the gravel is installed, the disu'ibution pipe is to be installed level with the
perforations faced downward. Gravel is then to be placed over the distribution pipe to
provide a minimum of 2 inches of cover over the pipe.
A silt barrier must be installed between the final gravel layer and the native soil backfill.
Ensure the silt barrier covers the entire gravel surface before placing backfill.
Monitor tubes shall be of four (4) inch diameter, installed approximately in the locations
shown on the design, and extend a minimum of 12 inches above final grade. The portion
ofthe monitoring tube extending through the gravel shall be perforated from the bottom of
thc trench to the invert of the distribution pipe. This is equivalent to the effective depth of
the gravel as noted on the design.
Backfill over the final gravel layer must not be less than twenty-four (24) inches.
Insulation must be installed when the backfill depth is less than thirty-six (36) inches. The
finish grade over the trench must be mounded to prevent the formation of a depression
after settling.
Page 3
Lot 13~ Block 2, Scimitar Subdivl.lon
May 30, 2001
MINIMUM MATERIAL SPECIFICATIONS:
I. Any septic tank proposed for installation must be constructed by a Municipal approved
septic tank manufacturer.
2. The following pipe materials arc approved for use in septic system installations in the
Municipality of Anchorage:
Type of Pipe Perforated Solid
Cast Iron Yes Yes
ASTM D3034 (PVC) Yes Yes
ASTM F810 (HDPE) Yes No
ASTM D2662 (ABS) Yes Yes
Use of a type of pipe other than listed above must bc approved by the inspecting engineer.
Insulation shall be at least 2" thick extruded direct burial polystyrene (Dow Cbemical
Company Styrofoam HI or equal).
Septic tank inlets and outlets shall lac fitted with watertight couplings (Cauldcr, Fcmco, or
equal).
A permeable nontoxic silt barrier (Typar 3401, Mirafi 140N, or equal) must be installed
between the final leachfield gravel layer and the native soil backfill.
All ieachfield gravel (sewer rock) shall be 0.5"-2.5" screened gravel with less than 3%
passing the #200 sieve.
When sand is being used as a filter material, its gradation specifications must conform to
current M.O.A. or D.E.C. requirements, which ever requirement applies.
INSPECTIONS:
Typically there will be a minimum of three (3) inspections required during the installation of the
wastewater disposal system. These inspections will occur as follows:
Page 4
Lot 13, Block 2, Scimitar Subdivision
May 30, 2001
The first inspection must be conducted after the excavation of ditches, pits,
trenches, or beds and before the installation of any gravel. A septic tank may be
set in place, but may not be backfilled before this inspection.
The second inspection must be conducted after the placement of the silt barrier,
gravel, distribution lines, standpipes, cleanouts, and insulation, but before the
placement of any other backfill.
3. The final inspection is to occur upon final grading ofthe property.
Often there will be more than these 3 inspections required. Especially with the installation of
multiple trenches, sand filters, pressurized distribution systems, etc. Thus, the inspecting engineer
is to be contacted at least 24 hours prior to the start of construction. If necessary, a pre-
construction meeting will take place on-site. The inspecting engineer will not coordinate, direct or
control in any way the contractors activities.
The owner shall contract with the contractor to perform the work outlined in these specifications
and plans and in accordance with the attached M.O.A. permit. There will be no contractual
arrangement existing between the contractor and S & S Engineering. S & S Engineering shall be
the owners representative and will inspect the work as stated above to document the contractors
activities. Final acceptance ofthe contractors work rests with the owner and the M.O.A.
S & S Engineering shall have no liability to the owner or to others for acts or omissions of the
contractor or any other persons performing work on this project or the failure of the contractor to
carry out the work in accordance with these construction documents. S & S Engineering's
inspecting engineer will not be responsible for the coustmction means, methods, techniques,
sequence, procedures or the safety precautions incident to this project.
CONTRACTOR / INSTALLER