HomeMy WebLinkAboutHERITAGE HILLS BLK 3 LT 6H eritage Hills Block 3 Lot 6 #015-221-12 11111101 Municipality of Anchorage Development Services Department Building Safety Division On -Site Water and Wastewater Program. 4700 S. Bragaw St. P.O. Box 196650 Anchorage. AK 99519-6650 Page of www ci anchorage.ak us (907) 343.7904 ON-SITE WASTEWATER DISPOSAL SYSTEM AND/OR WELL INSPECTION REPORT Permit Number: SWO50317 PID Number: 015-221-12 Nana Rick Onorato Wastewater System: ❑ New ® Upgrade Mdross 3961 McMahon Ave.. Anchorame. AK 99SI6 ABSORPTION FIELD Pouter Nunber of Bedrooms ® Deep Trwxh 13 Shaiim T,. O Bad O Mound 00~ LEGAL DESCRIPTION $aiFat V Total DWhhcm"nal vad. GPDdf FI. BbA lot Subdmswn owh to PO. bob= from «pool prso. Gavel dope, b ih PVa 3 6 Heritage Hills FI. F, To v Harper Seem Fm MWd abO+a ergn.l paoa Cav L.npth FI. Ft. Well: [:1 New F1 Upgrade Gav* wpm Nunoar ot Nws Divarw. baMesn Nos Ft.F Cta.ftatm (Pnvae. A B. C) Total DWI, Cased 10T«a abs"M area Pea Maternal Priva a Ft. FI Fl D3034 DnW Dae, DMbd Stan: water Lav* 1,0181M Das v,ataN F, A+ Home Services 1 9/11/05 YOM un Py s* a Carne H.pM Move Gouty TAN K nPM Ft FI SEPARATION DISTANCES ® Septic ❑ Holding ❑ S.T.E.P. ❑ Other. To Septic Absorption Lift Holding PNborJP"al ww a tr From Tank Field Station Tank Sewer Line Anchorage Tank 1000 ca weA 94'+ 100'+ NA NA 25'+ Steel Steel Nunoer« pertmeMa 2 surac.waar 100'+ 100'+ NA NA LIFT STATION L« Los 5'+ 10'+ NA NA a Ww Gi,I Fau dalcn 5'+ 10'+ NA NA =Pon lawn u p wra at pn weer •N m" in ti k Cwa., Doan NA *50'+ 1 NA NA Puny "a 6 MP•a fled w kapact o , P.dprm.d by Remarks *none known BENCH MARK tqn and .V. Old tank removed & abandoned per Cement slab - landing code. New tank placed & Insulated Assunad Ek aln 100 FL with foundation & post -tank cleanouts added. Waiver requested to 94' Engineer's Stamp between well and tank. pZjOFaA`gs�h ',.. .ser. »i 49 Inspections performed by: KND Engineering nc. IDates: 1*9/1 /05 .»a 2nd & 3'4 9/16/05 8/19/08 �9n Kenn Development Se es Department Approval �� s ti 11 a Reviewed and approved by: Date: — d I�l`9F'••9 /So�.����i 1,,\\\\ m« Iwo) SSl'`P�j 11111101 :Z Municipality Of Anchorage \ 1a). Mm VX;50 - Andwragc. Maslu) !W,19 144 • 471X1 t.hnurr INN I )flux: 1!X17) 313-M)l • Pax: (!M)7) 348- _1(X) hllp://���rwtnuud.arq Mayor Mark Begich Development Services Department August 27, 2008 Kenneth AT. Duffus, P.E. KND Engineering, Inc 20441 Ptarmigan Blvd. Eagle River, AK 99577 Subject: Waiver Request for Heritage 11 ills, Block 3 Lot 6 Waiver Request WR#: 080060 Parcel ID # 015-221-12 SW050317 Dear Kenneth 111. Duffus, P.E.: *�/_.1 _lam Department Your request for a waiver of the required 100 feet horizontal separation from the septic tank to the private well has been approved. The approved separation distance is 94.0 feet. This waiver approval applies to the existing septic tank to private well separation only. Any future upgrade to the on-site wastewater disposal system will require all separation distances be met or another approval from this department. If there are any further concerns or questions regarding this waiver, please call our office at 343-7904. Sincerely, Eel!toccn fu . Civil Engineer On -Site Water & Wastewater Program Community, Security, Prosperity Municipality of Anchorage Development Services Department • Building Safety Division On -Site Water and Wastewater Program j 4700 Bragaw Street P.O. Box 196650 Anchorage, AK 99519-6650 www.ci.anchorage.ak.us (907) 343-7904 Waiver Review Worksheet WR#:080060 PID#:015-221-12 HA/Permit# SW050317 Date Received: August 27, 2008 Legal Description: Ileritage Ililis, Block 3 Lot 6 Engineer: Kenneth D1. Duffus, P.E. KND Engineering, Inc 20441 Ptarmigan Blvd. Eagle River, AK 99577 Applicant: Waiver Requested: 94' Well to Tank Criteria: Geology Points: A. Water Table B. Soil Sorption C. Permeability D. Water Table Gradient E. Horizontal Separation Total: Waiver is Granted: X Ust Conditions or Reasons for above: Waiver is not Granted., Date: M7/08 By: Deb Wockenfuss Name of Reviewer ....................... 0.........................................60.80... Rec#: 112118 Amount: $920 Date Paid: 812 2008 Municipality of Anchorage CU. Dix 1!MWA) - Anchorage, A]aAa 99519-ff&) • 47(MI Hamm 16uu1 \ 011icc: (1917) 313-NMII • I:u: (!X171 ft13-K- MI hllp:/h����c.munLurl; Alayor A/ark Begich Development Scr%ices Dcpurtmcnl August 27, 2008 Kenneth M. Duffus, P.E. KND Engineering, Inc 20441 Ptarmigan Blvd. Eagle River, AK 99577 Subject: Waiver Request for Ileritage IIills, Block 3 Lot 6 Waiver Request WR#: 080060 Parcel ID # 015-221-12 SW050317 Dear Kenneth 51. Duffus, P.E.: n Met N00 Department Your request for a waiver of the required 100 feet horizontal separation from the septic tank to the private well has been approved. The approved separation distance is 94.0 feet. This waiver approval applies to the existing septic tank to private well separation only. Any future upgrade to the on-site wastewater disposal system will require all separation distances be met or another approval from this department. If there arc any further concerns or questions regarding this waiver, please call our office at 343-7904. Sincerely, ,a -w4 Deb Wockenfu Civil Engineer On -Site Water & Wastewater Program Community, Security, Prosperity Heritage Hills, Block 3 Lot 6 Parcel ID: 01522112 Waiver for 94 feet from well to tank Issued Aug 25, 2008 General 1. From the 2002 water sample, total coliform was 0, and total nitrates was 1.53 mg/L. A new tank was installed in 2005. 2. Any overflowing sewage would have to travel around the house to get to the well head. 3. The location of the system is in a visible area and any surfacing effluent will be seen and corrected. ADEC Criteria Water Table Depth of water bearing zone in well 219 feet Assumed bottom of tank 8 feet 211 feet 1'(111/190) + 7 Soil Sorotion Soil descriptions from well log DEC PTS Depth From Depth To Thickness gravel and clay 3 8 21 13 sand 1.5 21 28 7 gravel, sand and clay 3.5 28 132 gravel and sand 1 132 165 clay and sand 4.5 165 219 104 33 Calc. Pts 0.18 0.05 1.73 0.16 54 1.15 0 0.00 211 3.27 Permeabilitv Soil descriptions from well log DEC PTS Depth From Depth To Thickness gravel and clay 0 8 21 13 sand 1.5 21 28 7 gravel, sand and clay 0.5 28 gravel and sand 0.75 132 clay and sand 0.75 165 Water Table Gradient - Water table slopes away from the water source Assume -2.9% slope Horizontal Separation 94 feet between septic lank and well x=16/25+2.0 132 104 165 33 219 64 0 0 211 Calc. Pts 0.00 0.05 0.25 0.12 0.19 0.00 0.00 M Total Points Points 7.6 3.3 M. 2.4 Fi 16.5 A separation distance of 94' has points calculated at 16.5. Almost sure to be free from any form of contamination from household sewage. SW 050317 Heritage Block 3 P70Ii7 8/25/08 Water Table Gradient Calculation Heritage Hills, Block 3 Lot 6 35' Heritage Hills, Block 3 Lot 6 0' 9' '4� +Nn t ronwM August 19, 2008 AClERRA ENGINEERING AND SURVEYING, ING Jeff Poet, On -Site Engineering Technician Municipality of Anchorage Development Services Department On -Site Water & Wastewater Program P.O. Box 196650 Anchorage, AK 99519-6650 RE: HERITAGE HILLS BLOCK 3, LOT 6 — WELL/SEPTIC TANK WAIVER Dear Jeff, Per your request, we have re -verified the separation distance of 98 feet between the first septic tank cleanout and the well located on the referenced lot. We are therefore requesting that a waiver to 94 feet between the referenced well and septic tank be granted at this time. This well and septic system are located on the opposite sides of the house and have been in operation for over 37 years. Per ADEC Separation Distance Waiver Guidelines for SCRO: • Water Table (202' static well log) • Soil Sorption (See well log-clay/sand/gravel) • Permeability (See well log clay/sand) • Water Table Gradient (0%) • Horizontal Separation (94') ifYI va 7.50 points 2.50 points 3.00 points 2.90 points 2.70 points The point total indicates that the well would almost sure to be free or no contamination possible from any form of household sewage contamination. It appears that the moderate nitrate levels (1.53 mg/L) of the most recent water analysis of March 26, 2002 are not just isolated to the referenced well, but to the local area in general. 8/;Z/o8 Ui R I V E I? PTy 7h A/k T O UIE L[ Heritage Hills B3, L6 August 19, 2008 Page 2 of 2 Based on this analysis, we respectfully request that the waiver of 94 feet between the well and septic tank be granted. If you have any questions or require additional information, please contact me at 868-3792 / FAX 868-3793. Respectfully, A:rt" Cern Engineering & Surveying, Inc. Kenneth M. Duf us, 20441 PTAR\IIGAY RIND • EAGLE RIVER, AK 99577-8736 • Pit (907) 868-3791 • FAX (907) 868-3793 AS -BUILT SEPTIC TANK REPLACEMENT SITE PLAN Pip it 01 05031712 HERITAGE HILLS BLOCK 3 LOT 6 K�'D P. W O J_� X52 7/ /N� 10.0' — / EASEM IUTIUTY 1 I \ I 150' - r ---r EXISTI G PTEP GE I [f2EgY� 6� ld M Co 0 2 RAJ = 13 \FCO ef I A I I EXIST WELIJ I W/100' RADIUS / I� /1 ,�5 � A-1=31.17' B-1=46.40' 7 rw-44 A-2=37.47' 9. B-2=39.79' 4' SOLID FROM HOUSE OF .4L � / * 4 9* +/ D U ce 7ue .�a ,s ' 1 � qb' fESSION�� � f4Mw4. — 4 PREPARED FOR: RICK ONORATO 3961 McMAHON AVENUE ANCHORAGE, AK 99516 NEW 1000 fC�l / / SEPTI TK c / /I I Scale: 1 "= 50' FIELD BOOKS toMwuMm eaMDUMr. DRAM: MITIO 1MD ENGINEERING su"i"t oc M' kmd 20441 PTARMIGAN BLVD As T. DAME 09 30 05 EAGLE RIVER AK 99577-8736 D, raE aro: 2737 it Au'B FLE` 05062.dwg JOB"" 05-062 (907)696-6111/FAX (907)696-8111 MUNICIPALITY OF ANCHORAGE Development Services Department On -Site Water & Wastewater Program 4700 South Bragaw Street P.O. Box 196650, Anchorage, AK 99519-6650 (907) 343-7904 ON-SITE WASTEWATER DISPOSAL SYSTEM PERMIT Upgrade Permit Number: SW050317 Legal Description: HERITAGE HILLS BLK 3 LT 6 Design Engineer: 0070 KND Engineering Owner Name: RICK ONORATO Owner Address: 3961 MCMAHON AVE ANCHORAGE. AK 99516-2346 Date Issued: Aug 24, 2005 Expiration Date: Aug 24, 2006 Parcel ID: 015-221-12 Site Address: 012200 FREEDOM RD Lot Size: 16500 SQ. FT. Total Bedrooms: 3 Permit Bedrooms: 3 This permit is for the construction of: ❑ Disposal Field Q Septic Tank ❑ Holding Tank ❑ Privy ❑ Private Well ❑ Water Storage All construction must be in accordance with: 1. The attached approved design. 2. All requirements specified in Anchorage Municipal Code Chapters 15.55 and 15.65 and the State of Alaska Wastewater Disposal Regulations ( 18AAC72 ) and Drinking Water Regulations ( 18AAC80 ). 3, The engineer must notify DSD at least 2 hours prior to each Inspection. Provide notification by calling (907) 343-7904 ( 24 hours ). ( Not required for a Water Supply Permit only). 4. From October 15 to April 15, a subsurface soil absorption system under construction during freezing weather must be either: A. Open and closed on the same day. B. Covered, sealed, and heated to prevent freezing. 5. The following special provisions. - (EMERGENCY TANK REPLACEMENT) - SEPTIC TANK INSTALLATION MAYBE LOCATED NO LESS THAN FIVE FEET FROM ANY PROPERTY LINE OR BUILDING FOUNDATION; TEN FEET FROM ANY WATER SERVICE LINE; ONE HUNDRED FEET FROM ANY SURFACE WATER; AND ONE HUNDRED FEET FROM ANY PRIVATE WELL; AND THE SEPARATION DISTANCES REQUIRED BY 18AAC72 FROM WATER SUPPLY WELLS. Received By. Date: 8 2y oS" Date: 17 Z t u� Municipality of Anchorage Development Services Department Building Safety Division On -Site Water and Wastewater Program 4700 South Bragaw St. P.O. Box 196650 Anchorage, AK 99519-6650 www.ci.anchorage.ak.us (907) 343-7904 ON-SITE SEWER/WELL PERMIT APPLICATION FOR A SINGLE FAMILY DWELLING Parcell.D_ 015-221-12 PermitNumberSW Property owner(s) Rick Onorato Mailing address (1) 3961 McMahon Ave- Anchorage, Day phone _345-0035 AK 99516 Mailing address (2) Zip Code Legal description (Lot, Block & Sub'da Heritage Hills, Stock R, Lot 6 Legal description (Section, Township & Range) Lot Size 16500 Acres/Sq.Ft. Number of Bedrooms 3 THIS APPLICATION IS FOR: Sewer Only ❑ Well Only ❑ Sewer and Well ❑ Water Storage ❑ Sewer Upgrade THIS PROPERTY CONTAINS: Hot Tub ❑ Jacuzzi ❑ Swimming Pool ❑ Water Softening Unit ❑ Therapy Pool ❑ certify that the above information is correct. I further certify that this application is being made for a Single Family Dwelling and is in accordance with applicable Municipal Codes. Permit Fees: property owner or authorized agent) i Date of Payment: ?f o ��r1S� Receipt Number: -7895? .,. (Rev. 12100) Waiver Fees: Date of Payment: Receipt Number: 1-CINM ENGINEERING, INC. 20441 PTARMIGAN BLVD. EAGLE RIVER. AK 99577-8736 11/FAX August 24, 2005 Municipality of Anchorage Development Services Department On -Site Water & Wastewater Program P.O. Box 196650 Anchorage, AK 99519-6650 Subject: Septic Tank Upgrade — Heritage Hills, Block 3, Lot 6 Gentlemen: The owner has requested we proceed forward to obtain a septic permit to upgrade and replace the existing septic tank for the subject lot. The existing septic tank will be abandoned in place or removed in accordance with municipal standards. There are no public or private wells within 200' of our proposed system location except as noted. There is no surface water within 100' of the proposed system and there are no known curtain drains within 50'. We do not expect there to be any adverse effect on adjacent lots by the development of this system. If you have any questions, please contact me at 696-6111 /FAX 696-8111. Respectfully submitted, KNE) Engineering, Inc. hL enncth M. Duffu Attachments: On -Site Well and Sewer Application Wastewater Absorption System Details/Site Plan SEPTIC TANK REPLACEMENT SITE PLAN HERITAGE HILLS BLOCK 3 LOT 6 K D i UTILITY I EASEM I I � � I \ \\ I I NO PUBLIC WELLS WITHIN 200' OF PROPOSED SYSTEM. NO PRIVATE WELLS WITHIN 200' OF PROPOSED SYSTEM EXCEPT AS NOTED. OF ALAS G'49 9 +� KENN If US cy 1 HAAW ca "'Ron'sS14Npy dw z w O N 150' EXISTG I ,I SEEPAGES?7�C PIT 1 1 I APPROX LOICATION 1 EXIST WELY ,,t / w/100' RADIUS / --{ 30.0' REMOYE EXI$q 1000 IGAL/S.T. & REPC w/NEW 1000 A 1000 AL S.T. /I 1 L I � 1 DESIGN DETAILS 1. 3 BDRM X 150 GPD - 450 GPD 2. INSTALL 1000 GALLON SEPTIC TANK & INSULATE IF < 4' COVER 3. INSTALL FOUNDATION CLEANOUT AND POST—TANK CLEANOUTS. CONSTRUCTION NOTES: 1. CONTRACTOR WILL ENSURE MINIMUM 2% SLOPE INTO SEPTIC TANK. 2. CONTRACTOR WILL ENSURE ALL SEPARATIONS TO ADJACENT WELLS, SEPTICS, LOT LINES, FOUNDATIONS AND ALL OTHER SETBACKS. PREPARED FOR: RICK ONORATO 3961 McMAHON AVENUE ANCHORAGE, AK 99516 FIELD BOOKS compum; BDLNIDARY DRAW: STARING wEaED: Am MT: DATE: Dw RLE: CMD: ACA' RAc"' 05062.dwq I jm ""` 05-062""` 05-062 Scale: 1"= 50' PAGE 1 OF 1 1E ID ENGINEERING 20441 PTARMIGAN BLVD. EAGLE RIVER, AK 99577-8736 (907)898-8111/FAX (907)896-8111 1�9yIS 0. y A ...... .. ..... 4 - 3�­ -7. --- --- For J. O.Q.. NTe i 11 ...... ............ ........ ............. ................ Location .... TI-Ced r.--.Road(He ribaga_sub ....:Lot ... ... ... a \iI Date completed ..Juna 6 1 9-74 5 �&.q.. ..... -AjV1 Depth of Well... .22_,?.YQ.P,.t, ... fq.. , 0.1 ."Size of'casing...*., ........... ..................................... ...... �-'Distance to water.... ............ ...... .............. a ... .. Distance to water while pumping ... .... .............gyp..: 204. .................. ........ �.at rate of ......::::.....500..... ;:..::.:....gallons per hour. Description of Formation from 10 Tn--qnil Gravel and clay I 7 I 21 -24 Gvavei., -and "it'd clay rm=rP.1 and snnd A. I C1 2nd gnind I 15,5-1-219— 1�9yIS 0. y A 4 - GAAB-HD 1 Gi.ATER ANCHORAGE AREA BORO iH C., (> DEPARTMENT OF ENVIRONMENTAL DUALfi�( ' 3500 TUDOR ROAD ANCHORAGE, ALASKA 99507 279-8686 INSPECTION REPORT ON-SITE SEWAGE DISPOSAL SYSTEM s MAILING yr U•L,G' �ir�5y�f/C f• NAME /��� �r'���� ADDRESS PHONE LOCATION / �l� ��Ay� l�%��'� LEGAL DESCRIPTION All f-11<-� ZV-GZ-r h����s SEPTIC TANK: / NUMBER OF DISTANCE FROM WELL J C' -rl MATERIAL 5 COMPARTMENTS LIQUID LIQUID CAPACITY %( ('!' GALLONS. INSIDE LENGTH INSIDE WIDTH-DEPTH- SEEPAGE IDTH DEPTH SEEPAGE SYSTEM: SEEPAGE PIT NUMBER OF PITS_ / OUTSIDE DIAMETER OR WIDTH A/�' LENGTH ,1c� DEPTH � 1 LINING MATERIAL < /<°`i%e•0LrDISTANCE FROM WELL It� Z C - BUILDING FOUNDATION �G ��--����1'�;S J/ f NEAREST LOT LINE �� / l TOTAL EFFECTIVE ABSORPTION AREA (WALL AREA) /!'' SQ. FT. TILE DRAIN FIELD: DISTANCE FROM WELL TOTAL LENGTH FOUNDATI 'N,_ , NEAREST LOT LINE , OF LINES_ NUMBER OF LI 1 5 DISTANCE BETWEEN LINES TRENCH WIDTH ABSORPTI N AREA SQ. FT. LENGTH OF EACH LINE AL EFFECTIVE DEPTH: TOP OF TILE TO FINISH GRADE DEPTH OF FILTER MATERIAL BENEATH TILE —IN. ABOVE TILE WELL:kt DISTANCE FROM WATER U1 - TYPE 1U141 lDEPTH BUILDING FOUNDATION. SAMPLE , NEAREST NEAREST _ SEPTIC r SEEPAGE I OTHER inT iINF SEWER LINE—,TANK �C moi- SYSTEM Wi l— ,CESSPOOL , SOURCES_ DATE /V'y �� GREATER ANCHORAGE AREA BOROUGH i0 'A DEPARTMENT OF ENVIRONMENTAL QUALITY PERMIT NO. 3500 TUDOR ROAD POUCH 6-650 ANCHORAGE, ALASKA 99502 TELEPHONE 279-8686 SEWAGE DISPOSAL SYSTEM - APPLICATION AND PERMIT NAME OF APPLICANT j1�— MAILIN`/Gf ADDRESS PHONE INSTALLATION LOCATION JCU M L- t' AIF-- � � � � + � rl " 1J" l A I � LEGAL DESCRIPTION A DL INSTALLATION OF: SEPTIC TANK SEEPAGE PIT DRAIN FIELD OTHER , TYPE AND SIZE OF FACILITY TO BE SERVED FINANCED THROUGH TO BE INSTALLED BY I7 i1 c zL/'c-- SOIL TEST RESULTS .l lle) j� ♦='f` )"%�' XScL %���' NOTE: THIS PERMIT IS NOT VALID WITHOUT SOIL TEST COMPLETION DATE ANTICIPATED ��i R.� `7 / FINAL INSPECTION: 24 HOUR NOTICE REQUIRED. BACKFILLING OF ANY SYSTEM WITHOUT FINAL INSPECTION BY THE HEALTH DEPARTMENT AUTHORITY WILL BE SUBJECT TO PROSECUTION. 1 - SEPTIC TANK SIZE TYPE S/ EEPAGE AREA SIZE / ��� x TYPE MINIMUM DISTANCES, REQUIREMENTS DIAGRAM OF SYSTEM FOUNDATION TO SEPTIC TANK ' FOUNDATION TO SEEPAGE PIT �0 , DRAIN FIELD SEPTIC TANK TO SEEPAGE PIT WALL SEPTIC TANK _-1—, SEEPAGE PIT .�D T,DRAIN FIELD TO NEAREST LOT LINE. WELL TO SEPTIC TANK �.� V SEEPAGE PIT DRAIN FIELD , ALSO CONSIDER AREA WELLS. WATER MAIN TO SEPTIC TANK DRAIN FIELD SEEPAGE PIT SEPTIC TANK, SEEPAGE PIT , DRAIN FIELD TO RIVER, LAKE, STREAM. CAST IRON INTO AND OUT OF SEPTIC TANK AND INTO CRIB CROSSING GAP OF EXCAVATION 5 FEET INTO UNDISTURBED SOIL. 4 INCH DIAMETER CAST IRON SIPHON PIPES ON SEPTIC TANK AND SEEPAGE PIT FITTED WITH AIRTIGHT REMOVABLE CAPS. GRAVEL BACKFILL CONFORM TO BOROUGH REGULATIONS REGARDING INSTALLATION. HEALT AUTHORITY OR LICENSED DESIGNER I CERTIFY THAT I AM FAMILIAR WITH THE REQUIREMENTS OF GREATER ANCHORAGE AREA BOROUGH ORDINANCE NO. 28-68 AND THAT THE ABOVE DESCRIBED SYSTEM IS IN ACCORDANCE WITH SAID CODE. DATE j /L U APPLICANT'S SIGNATURE i 0 Fc ri cir Keith Burds.qn— —7L2�IL71 6 Heritage Hill le - L ; !&I! tl- Brown sandy silt (ML) 2--1 3--j Gray fine to medium gravel 4-4 zi (GW) Gray poorly graded sand with silty sand seams 8-14 9-1 W no Was 'I'VOUTIC, t 180 s _ua_re of Ay�C area re: rorre,l R. E...Carlisle I National Testin Services, Inc. Municipality of Anchorage Development Services Department Building Safety Division •"' On -Site Water and Wastewater Program 4700 South Bragaw St. P.O. Box 196650 Anchorage, AK 99519-6650 www.ci.anchorage.ak.us (907) 343-7904 CERTIFICATE OF HEALTH AUTHORITY APPROVAL FOR A SINGLE FAMILY DWELLING Parcel I.D. 015.221.12 HAA # X14 Do -0115 Expiration Date: %— E' 02 1. GENERAL INFORMATION Complete legal description Heritage Hills Lot 6 Block 3 Location (site address or directions) 12200 Freedom Rd Anchorage AK 99516-2346 Current Property owner(s) Joe Neill Day phone Mailing address Lending agency Mailing address Real Estate Agent Mailing Address Same as above Day phone Hank Groper - Totem Realty. Inc. Day phone 272-0571 794 East 15'" Avenue Anchorage AK 99501 Unless otherwise requested, HAA will be held by DSD for pickup. 2. NUMBER OF BEDROOMS: 2 3. TYPE OF WATER SUPPLY: Individual Well Individual Water Storage ❑ Community Class Well ❑ Public Water System ❑ TYPE OF WASTEWATER DISPOSAL: Individual On-site Individual Holding tank ❑ Community On-site ❑ Public Sewer ❑ The Municipality of Anchorage Development Services Department (DSD) Issues Certificates of Health Authority Approval (HAA) based only upon the representations given in paragraph 4 by an Independent professional civil engineer registered in the State of Alaska. Certificates of Health Authority Approval are required for the transfer of title (except between spouses) for properties served by a single-family on-site wastewater disposal and/or water supply system. DSD also issues HAAs upon request to homeowners. Certificates of Health Authority Approval are valid for 90 days from the date of issue for properties served by a private or Class C well and may be reissued with new water sample results. (Certificates may be reissued for a period of up to one year with valid water samples.) Certificates are valid for one year for properties served by Class A or B wells or a public water system. The Municipality of Anchorage is not responsible for errors or omissions in the professional engineer's work. 4. STATEMENT OF INSPECTION BY ENGINEER As certified by my seal affixed hereto and as of the validation date shown below, I verify that my Investigation, based on procedures outlined in the Health Authority Approval Guidelines for this application, shows that the on-site water supply and/or wastewater disposal system is(are) safe, functional and adequate for the number of bedrooms and type of structure indicated herein. I further verify that based on the information obtained from the Municipality of Anchorage files and from my investigation and inspection, the on-site water supply and/or wastewater disposal system Is(are) in compliance with all applicable Municipal and State codes, ordinances, and regulations in effect at the time of installation. Name of Firm KND ENGINEERING Phone. (907) 696.6111 Address 20441 Ptarmigan Blvd Eagle River AK 99577 Engineer's Printed Name Kenneth M. Duffus Date 04102/01 51 ]NEER S 5. DSD SIGNATURE d�; xonae.n „. Jutrly 16 —L Approved for L bedrooms. t��F9 •..,•• • •�,.•• Disapproved.RopEss)o%� Conditional approval for bedrooms, with the following stipulations: Additional Comments Crw. ,ryG • WATFG ANI1 •. Attachments: HAA Checklist X Maintenance Agreements Septic System Advisory Supplemental Engineer's Report Well Flow Advisory Other By: /���^ "' � �� Original Certificate Date: 44 (R.. 01102) Municipality of Anchorage Development Services Department 1; Building Safety Division On -Site Water & Wastewater Program 4700 South Bragaw St. P.O. Box 196650 Anchorage, AK 99519-6650 www.cl.anchorage.ak.us (907) 343-7904 HEALTH AUTHORITY APPROVAL CHECKLIST Legal Description: Herbg2 .,:::_ Lot e aleck 3 Parcel ID: 015.221.12 A. WELL DATA Well typerip Kate If A. B, or C provide PWSID # _ Date completed 61611974 Sanitary seat (YIN) Y Total depth 224 ft. Cased to 224 ft. FROM WELL LOG Date of test 616171 Static water level 202 ft. Well production 10 9 p•m WATER SAMPLE RESULTS: Coliform 0 colonies/100 mi. Nitrate 1.53 mg./I. Arsenic: NA mg -A. Date of sample: 3126102 B. SEPTICIHOLDING TANK DATA Well Log (YIN) Y Wires properly protected (YIN) Y Casing height (above ground) 30" AT INSPECTION X14612002 191 ft. 5.73 9 -P.M. Other bacteria 0 colonies/100 ml. Collected by: KNO Engineering Inc Tank Type/Material SeptidSteel Date Installed 1071 Tank size 1000 gal. Number of Compartments 2 Cleanouts (YiN) X100 Foundation cleanout (YIN) `[(inside foundation) • Depression over tank (YIN) bL_High water alarm (YIN) N Date of pumping 04 01102 Pumper Anchorage Cesspool Pumping C. ABSORPTION FIELD DATA Date installed 1971 Soil rating (g.p.d./ft2 or ft=lbdrrn)1_S0 System type Pit Length 10—_ ft. Width 16 ft.Gravel below pipe 12 (pit depth) ft. L'D Total depth ff. Eff. absorption area 612 fe Monitoring tube `,j Depression over field H Date of adequacy test 1_126102 Results (Pass/Fail) Pass For 2 bedrooms Fluid depth in absorption field before test 26 In. Water added -390 gal. New depth 41 in. Elapsed Time: 285 min. Final fluid depth 25 in. Absorption rate >= 300+ g.p.d. Any rejuvenation treatment (past 12 mo.) (YIN & type) N If yes, give date D. LIFT STATION Date installed NA Size in gallons Manhole/Access (Y/N)___� 'Pump on" level at _ in. "Pump off" level at _ In -High water alarm level at In. Datum Cycles tested Meets alarm 8 circuit requirements? E. SEPARATION DISTANCES SEPARATION DISTANCES FROM WELL ON LOT TO: Septic tank/lift station on lot _1001+ Absorption field on lot 1001+ Public sewer main _75'+ On adjacent lots 100'+ On adjacent lots •-25' Public sewer manhole/cleanout 1001+ Sewer /septic service line 25'+ Holding tank 1001+ SEPARATION DISTANCES FROM SEPTIC/HOLDING TANK ON LOT TO: Building foundation —Et__ Property line E++ Absorption field -5'+ Water main 101+ Water service line 10'+ Surface water 1001+ Wells on adjacent lots 100'+ SEPARATION DISTANCE FROM ABSORPTION FIELD ON LOT TO: Property line _ 10'+ Building foundation '+ Water main _101+ Water Service line 101+ Surface water 00'+ Driveway. parking/vehicle storage 0' fon edge of drivevrevl Curtain drain 50'+ Wells on adjacent lots 001+ F. COMMENTS G. ENGINEER'S CERTIFICATION ,:!X0;:•••"•••% :,q e Cj S I certify that I have determined through field Inspections and rs f •: • TN N ;y ••H review of Municipal records that the above systems are in conformance with MOA HAA guidelines In effect on this date. ..,•., Engineer's Printed Name Kenneth M. Duffus c� : �enn`ea,'M z„ _. �t v�•$TAfflr116 Date 04/0212202i F9 �•' FeP OF HAA Fee $375.00 Waiver Fee $ _ Date of Payment 04/0, Date of Payment Receipt Number O 11 MP / ' Receipt Number. (Rev. 12101) / P.Pa a Z' to urwty W"am...r - GPC, : 215-1 F• 5CVr--. K''7 AS.BUILT SURVEY SCALE LM15p M �4 L FKENNETH G. LANG, L.S. 1731 GEORGE BELL CIRCLE, ANCHORAGE, ALASKA 99515 (907) 34t)-b4/b I hereby certify -that I have surveyed the following described �••,�r^} At aP4 property:••Lot''(_, Block'<� 3 i'�t'-¢1tACi8'NitlS'���3. • • •. ,&Wr-io0'&6C Recording District, Alaska, and that the improve- R �, •'••�� C%'AP ments situated'.thereon are within the property lines and do not ��: �y,;�.�, SR (► encroach onto•the property adjacent thereto that no improvements 00.40 v x : �. —. � * 4 on the property lying adjacent thereto encroach on the surveyed 0 ''// C premises and that there are no roadways, transmission lines or r••�. •` tJ other visible easements on said property except as indicated p '5,-,23 ; K^^^ c t.^o , d P Pe Y P ^.; LS - 5202 v hereon.t , •..,•..•• :, u .. .... ... ... , Gr Dated this the .24*' day of' AUC ue.V , 1988- , at Anchorage, Alaska. 22i /z. MUNICIPALITY OF ANCHORAGE DEPARTMENT OF HEALTH & HUMAN SERVICES DIVISION OF ENVIRONMENTAL SERVICES 2S CERTIFICATE OF INSPECTION FOR HEALTH AUTHORITY APPROVAL OF ON-SITE SEWER AND WATER FACILITY 264-4744 / p Application Date k4A, P - 1, 1. GENERAL INFORMATION (MUST BE COMPLETED PRIOR TO SUBMITTAL) (a) Legal Description (include lot, block, subdivision, section, township, range) [4:11-s at, 22 .moi nac/e Location (address or directions) l 2- 2 o -o P_ ae (b) Property Owner �� n��� r Telephone: Home 3 o ���� Business 3q9- UP 9:91 Mailing Address P, Q l3o%�jK /I a L! '7 L C? L? (c) Lending Institution "rC " F_e_/Telephone Mailing Address Ar rc a v �� evu� S (d) Real Estate Company and Agent %l b fLr 1 (e) Address Telephone Mail the HAA to the followino address: or: Check here, if hold for pick up. List contact person and day phone number below. 1*2 A-2 I , 3 41,6 2. TYPE OF RESIDENCE Single -Family Number of Bedrooms _ 3. WATER SUPPLY , Individual Well Community ❑ Public ❑ Note: If community well system, must have written confirmation from the State Department of Environmental Conservation attesting to the legality and status. 4. SEWAGE ///DISPOSAL Onsite y5 Public ❑ Community ❑ Holding Tank ❑ Note: If community well system, must have written confirmation from the State Department of Environmental Conservation attesting to the legality and status. Page 1 of 2 72-025 (Rev 8/86) Front 5. ENGINEERING FIRM PROVIDING INSPECTIONS, TESTS, FILE SEARCH, DATA AND INFORMATION As certified by my seal affixed hereto and as of the validation date shown below, I verify that my investigation of this Health Authority Approval shows that the on-site water supply and/or wastewater disposal system is safe, functional and adequate for the number of bedrooms and type of structure indicated herein. I further verify that based on the information obtained from the Municipality of Anchorage files and from my investigation and inspection, the on-site water supply and/or wastewater disposal system is in compliance with all Municipal and State codes, ordinances, and regulations in effect on the date of this inspection. n Name of Firm Address Date ao _ Telephone o2? ,3 �1 3 Le- lJ ;' :•l,• tom' `;' �•.S'�F(, r , . .. • • . ... Engineer's Seal - ido. 2_225-E: 1971 6. DHHS APPROVAL Approved for 3 bedrooms by "`"`�'1 I� i� Date Approved Disapproved Terms of Conditional Approval Conditional CAUTION The Municipality of Anchorage Department of Health and Human Services (DHHS) issues Health Authority Approval certificates based only upon the representations given in paragraph 5 above by an independent professional engineer registered in the State of Alaska. The DHHS does this as a courtesy to purchasers of homes and their lending institutions in order to satisfy certain federal and state requirements. Employees of DHHS do not conduct inspections or analyze data before a certificate is issued. The Municipality of Anchorage is not responsible for errors or omissions in the professional engineer's work. Page 2 of 2 72-025 (Rev 6/e6) Beck IcteP.41fiY of C"68p1P,PLITY OF ANCHORAGE (MOA) yN jpl S�RVtQ?A � 6L AUTHORITY APPROVAL (HAA) 11UIRQN CHECKLIST - FEBRUARY 1984 264-4720 �j Legal Description: Lot �F$K A. WELL DATA Well Classification I?e,.s If A, B, C�/D.EE C�N�Aa C. Approved (Y/N) Well Log Present (Y/N) x Date Completed "' b� / Yield Total Depth 4W V Cased to %Z 2 y Depth of Grouting N O lYL_ Static Water Level 0207. Pump Set At aoP TTo�//'�i Casing Height Above Ground 30.r Sanitary Seal on Casing (Y/N) / ^ Electrical Wiring in Conduit (Y/N) .4 Depression Around Wellhead (Y/N) Separation Distances from Well To Septic/Holding Tank on Lot 1 O ; On Adjoining Lots ';P �0 1q To Nearest Edge of Absorption Field on Lot ;On Adjoining Lots Oi� x he� 713 K3 To Nearest Public Sewer Line NIA To Nearest Public Sewer #� Cleanout/Manhole N/A To Nearest Sewer Service Line on Lot > /y Water Sample Collected by Water Sample Test Results Comments B. SEPTIC/ham TANK DATA S ; Date T �`IRYIB� Date Installed j 471 Size) D -6o No. of Compartments Standpipes (Y/N) ON+~ Air -tight Caps (Y/N) — Foundation Cleanout (Y/N) ire�1 Depression over Tank (Y/N) `l Date Last Pumped MY 2 �Ra Pumping/Maintenance Contract on File (Y/N) NA ; for NA Holding Tank High -Water Alarm (Y/N) �4A Temporary Holding Tank Permit (Y/N) WA Separation Distances from Septic/Holding Tank: To Water -Supply Well 14Q 3 To Building Foundation (Q To Property Line > I C) To Disposal Field /0 To Water Main/Service Line Course Comments Page 1 of 2 72-026(11/84) To Stream, Pond, Lake, or Major Drainage C. ABSORPTION FIELD DATA Soils Rating in Absorption Strata 8a Type of System Design GoNCrZI TiE CP—Ira Date Installed 1q-71 Length of Field la ze /6 �4 / Z Width of Field Depth of Field Z� Gravel Bed Thickness Square Feet of Absorption Area 2 Standpipes Present (Y/N) O NA Depression over Field (Y/N) N tDate ofLastAdequacy Test SIA V48F3 Results of Last Adequacy Test 7 lTAL Rez&v,0�� Separation Distance from Absorption Field: To Water -Supply Well To Building Foundation 2(P To Property Line Lot No j4 e. ; On Adjoining Lots To Existing or Abandoned System on /t9-?) f To Water Main/Service Line J /O To Cutbank (if present) NoMC To Stream/Pond/Lake/or Major Drainage Course C To Driveway, Parking Area, or Vehicle Storage Area C 014 Q� � � a(iu&&0_ tl/'an Comments _ D. LIFT STATION Date Installed Size in Gallons "Pump On" Level at High Water Alarm Level at Tested for — Electrical Codes (Y/N) Comments Dimensions Manhole/Access (Y/N) "Pump Off" Level at ** Check Permitted Bedroom Rating Against HAA Request ** Vent(Y/N) Pumping Cycles during Adequacy Test. Meets MOA I certify that I have checked, verified, Wonformedtoall MOAandHAA guidelines in effect on the date of this inspection. Signed Date Company — MOA No. Receipt No. Date of Payment ✓ d� Amount: $ os�6� 2 Page 2 of 2Do //1_��(3��11DL- (a-1� (u 72-026 (11/84) ��) ea� 11 Jlp Engineer's Seal Municipality of Anch` -brage Department of Health and Human Services dhh5 825 "L" Street Tom Fink, Mayor P.O. Box 196650 Anchorage, Alaska 99519-6650 343-4744 July 12, 1988 Tobben Spurkland, P.E. 203 West 15 Avenue "C", Suite 203 Anchorage, Alaska 99501 Subject: Waiver Request for Lot 6 Block 3 Heritage Hills S/D Waiver Request #WR88-025, #H88-0204 Dear Mr. Spurkland: Your request for waiver of the required 100 foot separation of a septic system to a private well has been approved. The approved separation distance is 95 feet. This waiver approval applies to the existing septic system to well separation only. Any future upgrade to either will require all separation distances be met or another approval from this department. Sincerely, bantv - jv Daniel J. Roth Civil Engineer On-site Services DJR/ljw#6 VUV ��LADV®ga203W.1 CONSULTING ENGINEER &ICIPALITY OFNTft1ZFn 1A � 1! RECEIVED Municipality of Anchorage Division of Environmental Health Department of Health and Social Services 820 L Street Anchorage, Alaska 99501 ""C SUITE 203 ALASKA 99501 19071 279-3916 May 25, 1988 Subject: REQUEST FOR WAIVER OF SEPARATION DISTANCES FOR PRIVATE WELL TO ABSORPTION FIELD LOT 6, BLOCK 3, HERITAGE HILLS JOE NEILL Gentlemen,- We entlemen; We are submitting a request for waivers from the separation distances stated in Title 18, Alaska Administrative Code, Chapter 80.020. During an Health Authority Inspection on May 24, 1988 is was discovered that the distance between the well on lot 6 and the absorption field on lot 7, Block 3, was 95 feet, five feet less than the required 100 ft. The well was installed in 1971 and the septic system in 1972. Therefore the well was in compliance at the time of installation, but the septic system on lot 7 was in violation of the requirements when it was installed. The well is located up hill from the septic system. According to the well log the well is 224 feet deep with static water level at 202. Three clay layers were identified with a total thickness of 172 feet. By going through the DEC's procedure of analyzing the potential for contamination I arrive at the following points: Ground Water Soil Sorbtion Permeability Gradient Separation Total (at 202 ft. ) 7.50 ( Sand/ Gravel) 1.50 ( Clayey Sand) 3.00 ( 0 ) 2.00 ( 95 ) 3.00 17.00 Conclusion: Chemical contamination possible but unlikely. Please issue an waiver for Yours Tobbe Spurkland P. this well. /iJ W. 15th "C" SUITE 203 �O o L7UV ���U�I��UVUVD9 �o�o 2A CHORAGE,EALASKA99501 CONSULTING ENGINEER TELEPHONE: (907) 279-3916 RESIDENTIAL WELL INSPECTION LEGAL: Lot 6, Block 3, Heritage Hills'-. LOCATION: 12200 Freedom Road `,;,., << OWNER: Joe Neill 6.•40 €. ( 5j- TYPE OF WELL: Residential Single Family ''. lU(JE L9'1 WELL LOG AVAILABLE: Yes INSTALLATION REQUIREMENTS MET: NO. Distance to neighbor's septic system (crib) 95 ft. Required distance is 100 ft. Waiver requested. WELL YIELD FROM WELL LOG: 10 gallons per minute PUMP YIELD FROM TEST: 6.5 gallons per minute DATE OF INSPECTION: May 24, 1988 TEST PROCEDURE: Well was pumped at a constant rate while the drawdown was monitored with an acoustic probe. At the beginning of the test water level was found at 199 feet below top of casing. At a pumping rate of 6.5 gallons per minute the water level dropped to 202 feet after 5 minutes of pumping and remained at that level for the remainder of the test, 70 minutes. A total of 460 gallons were pumped. The well recovery was instantaneous . TEST FOR E.COLI AND TOTAL NITROGEN: Water was tested for E.Coli and total nitrates on May 25, 1988 E.Coli 0. Total Nitrates 0.65 mg/l. Max. allowable Total Nitrates 10mg/1. TEST RESULTS: This well meets the requirements of the Municipality of Anchorage. THIS WELL WILL PRODUCE MORE THAN 3 GALLONS PER MINUTE FOR MORE THAN FOUR HOURS The Municipal requirement for well flow is 150 gallons of water per bedroom per day. This well exceed this requirement. The assessment of the condition of the well applies only to the conditions as of the day tested. The flow rate may change due to subsurface conditions that may not be observed from the surface, and changes in the land use and other factors that may impact the aquifer feeding the well. 03 W. 15th AV"C" SUITE 203 lJ O l� �U V�UUl7�UVD9 �p�p "'�2ANCHORAGEEALASKA 99501 CONSULTING ENGINEER TELEPHONE: (907) 279-3916 SEPTIC SYSTEM ADEQUACY TEST LEGAL: Lot 6, Block 3, Heritage Hills LOCATION: 12200 Freedom Road �•.i.. s OWNER: Joe Neill "."°°° 3 RESIDENCE: Single Family, Three Bedrooms il,'•" '1uiVE 27225 WELL: WELL: On Site. Single Family o.•. = 4.. SEPTIC SYSTEM: FROM MUNICIPAL RECORDS: TANK: Stack Steel 1000 gal. Two Compt. ABSORPTION SYSTEM: Concrete Ring Crib ABSORPTION AREA: 612 sq.ft. SOIL RATING: 180 INSTALLATION DATE: August 1971 DATE OF LAST PUMPING: May 256, 1988. Marx DATE OF TEST: May 14, 1988 TEST PROCEDURE: System was inspected and measured. Tank was found with 3 feet of cover and a liquid depth of 49 inches. Crib was 12 feet deep with 91 inches of liquid. 460 gallons of clean water were added to the crib while the water levels in the tank and the crib were monitored. Tank level did not change. Water level in crib came up 17 inches. The infiltration rate was monitored for 30 minutes. During this time the waterlevel in the crib dropped 5 inches, indicating a rapid infiltration. TEST RESULT: This system meets the code requirements of the Health and Social Services Department of the Municipality of Anchorage. NOTE The operational life of all septic systems depends on the local soil conditions, groundwater levels that may fluctuate during the year, and the water usage of the family being served by the system. These conditions are outside the control of the evaluator of this septic system. We can therefore not give any estimate of how long this system will function satisfactory for current or future occupants.