Loading...
HomeMy WebLinkAboutDENALI VIEW BLK 3 LT 6benali Vi w Block 3 Lot 6 #015-461-07 Municipality of Anchorage On-Site Water and Wastewater Section • (907) 343-7904 Page 1 of 3 ON-SITE WASTEWATER INSPECTION REPORT Permit Number: OSP191309 PID Number: 015-461-07 Dwelling: ■❑ Single Family (SF) ❑ with ADU ❑ Duplex (D) ❑ Two Single Family Project: ❑ New ❑ Upgrade Name STEPHEN MARSHALL ABSORPTION FIELD ❑ Deep Trench ❑ Wide Trench ❑■ Bed ❑ Mound Site Address 12300 SULTANA CT *ANCHORAGE, AK ❑■ Other Phone Number of Bedrooms Soil Rating Total depth from original grade 907-301-8047 5 *2.0 GPD/SF SEE DWG Ft. LEGAL DESCRIPTION Depth to pipe invert from original grade SEE DWG Ft. Gravel depth beneath pipe 0.53 Ft. Subdivision Block Lot DENALI VIEW; BLOCK 3, LOT 6 Fill added above original grade SEE DWG Ft. Gravel length 30 Ft. Township Range Section N/A Gravel width 12 Ft. Beds: Number of Lines 5 Distance between lines 2.5 Ft. SEPARATION DISTANCES To Septic Absorption Lift Station Holding Sewer Total absorption area Number of trenches Dist. between trenches From Tank Field Tank Line 360 Ft2 - - Ft. Well *50'+ 25'+ TANK ❑ Septic ❑ S.T.E.P. ❑ Holding ❑ Other Manufacturer Capacity Surface Water *50'+ Gal. Material Number o partments Lot Line 10,+ NA Foundation 10,+ LIFT STATION Manufacturer Capacity Gal. Remarks *CAT III - PER OWNER SEPTIC TANK WAS REPLACED WITHOUT A PERMIT IN 2003 Alarm loc Electrical installed by PIPE MATERIAL House to tank UNK Tank to1785 drainfield Installer A+ HOME SERVICES Drainfield 1785 CO/MT3034 Inspector DAVID GARNESS & TIM ECKLUND BENCH MARK (Assumed elevation) 97.55 ft Inspectiond1st 7/31/19 7/31/19 Location and description 2nd dates: TOP OF MANHOLE 3rd 8/1/19 4th ON-SITE WATER AND WASTEWATER SECTION APPROVAL Engineer's Stamp 0600 �O Date .........¢.. 9s,4p0 oo ............... ....... D Septic System _ ­_L 000 A795arne s. ApprovedDatesel Note: this approval does not include well permit requirements. Opo rofess'O°o� #AECC884 0000 d (Kev u5N2/18) PERMIT NUMBER: OSP191309 A I B F C FCO 21.3 5.2 36.5 STI 23.1 16.9 44.6 ST2 17.9 22.7 55.3 MH 16.9 24.2 57.1 MT1 28.3 30.2 57.7 MT229.5 36.8 69.9 MT3 60.0 64.2 86.8 MT4 57.6 57.9 75.7 RECORD DRAWING PARCEL ID 015-461-07 NUMBER. 1 00'WELL RADIUS / I \ I DECK •:; •. . DENALI VIEW; BLOCK 3, LOT 5 MT2 M EXISTING 4 MT S BEDROOM HOUSE \ ?i MT1 =•'''• S C T4 •• •'' K \ NEW IDSF REBUILD •�- ORNE�P +� •.. I THE STEP TANK INSTALLED IN 2000 WAS REPLACED WITHOUT A PERMIT IN 2003 PER CONVERSATIONS WITH THE OWNER; ATTACHED IS THE RECEIPT FOR THE SEPTIC TANK I INSTALLATION FROM A+ HOME SERVICES; SEPTIC TANK WAS EXPOSED BY A+ HOME SERVICES AND INSPECTED BY MOA I DENALI VIEW; BLOCK 3, LOT 7 ONSITE EMPLOYEE TIM ECKLUND AND DAVID GARNESS PRIOR TO THE INSTALLATION OF THE IDSF / � N SCALE: / 1 1" = 40' GARNESS ENGINEERING GROUP, Ltd — ENGINEERING o SALES o CONSULTING — — - 3701 E. TUDOR ROAD. SUITE 101 'ANCHORAGE. AK 99507' PHONE (90713376179' FAX (9 071 3 3 632 4 6' WEBSITE: vnvw.aamessenameema.com PREPARED FOR: PHONE NUMBER: PAGE NUMBER: SHARON MARSHALL 907-301-8047 2 OF 3 LEGAL DESCRIPTION: DRAWN BY: DENALVIEW; BLOCK 3, LOT 6 D.J.G. TYPE OF WORK: DATE: SEPTIC SYSTEM RECORD DRAWINGS 8/7/2019 -q •cp —.4 .... \, LICENSE 844, �;;;`S`% #AECC884 PERMIT NUMBER: PARCEL ID NUMBER: OSP191309 RECORD DRAWING 015-461-07 GEG WAS NOT PRESENT DURING THE SEPTIC TANK 'SLUDGE IN 1ST COMPARTMENT OF TANK DID NOT ALLOW INSTALLATION; PER OWNER AND RECEIPT PROVIDED BY FOR AN ACCURATE MEASUREMENT TO BOTTOM OF TANK A+ HOME SERVICES, THE TANK WAS REPLACED IN 2003 WITHOUT A PERMIT; ALL ELEVATIONS WERE CALCULATED IN 2019 AND HAVE LIMITED ACCURACY TANK SIZE IS ASSUMED BASED UPON PREVIOUS TANK SIZE FINAL GRADE = 97.16-99.42 TOP OF TANK STS ST2 MH AT INLET = BUNK TOP OF TANK AT OUTLET = 91.3 /(ASSUMING A T TANK DIAMETER) EXISTING VERT OF S.T.E.P. TANK INSTALLED IN 2003 INF BUNG IN INLET BUNK PER OWNER AND A+ HOME SERVICES. MAX BURIAL DEPTH AND VOLUME IS UNKNOWN -ASSUMED ji 2000 GALLONS BENCHMARK SHOWN ON 2000 INSPECTION REPORT ORIFICES DRILLED ARE 1/8" DIAMETER AT 2 FEET ON CENTER COULD NOT ACCURATELY BE DETERMINED; THEREFORE, ELEVATIONS WHERE SHOT AND FILTER FABRIC CALCULATED AFTER THE SYSTEM WAS EXPOSED MT (ONE AT EACH CORNER TYP.) FINAL GRADE = 95.9-97.5 R INVERT OF NEW DISTRIBUTION LINES = 90.93 12'+ ORIGINAL AIR LINE GARNESS ENGINEERING GROUP, Ltd ---_--- ENGINEERING o SALES o CONSULTING— - 3701 E. TUDOR ROAD, SUITE 101 'ANCHORAGE, AK 99507' PHONE (907)337-6179- FAX (907) 3383246' WEBSITE: w gamessengineenng.com PREPARED FOR: PHONE NUMBER: PAGE NUMBER: SHARON MARSHALL 907-301-8047 3 OF 3 LEGAL DESCRIPTION: DRAWN BY: DENALVIEW; BLOCK 3, LOT 6 D.J.G. TYPE OF WORK: DATE: � SEPTIC TANK AND DRAINFIELD PROFILE 1 8/7/2019 WASHED PEA GRAVEL -OP OF NEW SAND = 90.40 - BOTTOM OF "OLD" SAND WAS SHOT AT 90.30 BOTTOM OF SYSTEM = WAS NOT EXPOSED DURING INSPECTION F . ..............., 0 • .. ............• •...........• 0 0♦ :t a A. Gar ss :: om ♦♦% C -7 �_= • LICENSE 1ItIR�FESS1v:���� #AECC884 1������ / 7/ /. 11 )1-1 MUNICIPALITY OF ANCHORAGE 1/3�n�' On-Site Water&Wastewater Program ,•',ver,t S{, PO Box 196650 4700 Elmore Road Anchorage,Alaska 99519-6650 Phone:(907)343-7904 Fax:(907)343-7997 http://www.muni.org/onsite Rh�HORTGE epartmenc On-Site Wastewater Disposal System Permit Permit Number: OSP191309 Effective Date: 7/23/2019 Work Type: Septic Upgrade Expiration Date: 7/22/2020 Tax Code Number: 01546107000 Site Legal Address: DENALI VIEW BLK 3 LT 6 G:2741 Site Mailing Address: 12300 SULTANA CT, Anchorage Owner: MARSHALL STEPHEN & Lot Size in Sq Ft: 42115 Design Engineer: GARNESS ENGINEERING GROUP LTD Total Bedrooms: 5 This permit is for the construction of: Disposal Field 0 Septic Tank 0 Holding Tank 0 Privy 0 Private Well 0 Water Storage All construction shall be in accordance with: 1. The attached approved design. 2. All requirements specified in Anchorage Municipal code Chapters 15.55 and 15.65 and the State of Alaska Wastewater Disposal Regulations (18AAC72) and Drinking Water Regulations (18AAC80) 3. The wastewater code requires inspections during the installation. The engineer shall notify the Development Services Department per AMC 15.65. Provide notification by calling (907) 343-7904 (24/7). 4. From October 15 to April 15, a subsurface soil absorption system under construction during freezing weather shall be either: a. Opened and Closed on the same day, or b. Covered, sealed, and heated to prevent freezing Special Provisions: No exception to total absorption field area being 15 sq.ft. less than required, utilizing the 2 gpd/sq.ft. soil rating required of an IDSF system. 7 0Received By: Date Issued By: feljOlea, 6-AitD- Date: 7 aZ 3 1 9 MUNICIPALITY OF ANCHORAGE Community Development Department - Phone: 907-343-7904 Development Services Fax: 907- 343-7997 On-Site Water & Wastewater Program Mayor Dan Sullivan On-Site Sewer/Well Permit Application For A Single Family Dwelling Parcel I.D. 015-461-07 Property owner(s) Steve& Sharon Marshall Day phone 907-301-8047 Mailing address 12300 Sultana Court 'Anchorage. AK 99507 Site address 12300 Sultana Court *Anchorage. AK 99507 Legal description (Sub'd, Block & Lot) Denali View; Block 3, Lot 6 Legal description (Township, Section & Range) Lot Size Sq.Ft. Number of Bedrooms 5 APPLICATION IS FOR: APPLICATION IS AN: TYPE OF DEWELLING: (®all that apply) Initial Absorption Field ® ❑ Single Family (SF) Upgrade ® (w/wo ADU) Septic Tank ❑ Duplex (D) ❑ Renewal ❑ Holding Tank n Multiple Dwellings ❑ Privy ❑ T OS (SF and/or D) Private Well ❑ Water Storage ❑ THIS APPLICATION INCLUDES A VARIANCE/WAIVER REQUEST FOR: N/A Distance: - I certify that the above information is correct. I further certify that this is in accordance with applicable Municipal codes. GARNESS ENGINEERING GROUP, Ltd. (Signature of property owner or authorized agent) Permit/Rush Fees: 15 Waiver Fees: Date of Payment: -7-lict 9 Date of Payment: Receipt Number: n01193 L7 Receipt Number: Permit No. 05P1` 1367 Waiver No. (Rev.01/11) . t• __ Quaiiics GARNESS ENGINEERING GROUP, LtdAdvanced Trevnt 5, C,„'" ENGINEERING SALES CONSULTING Cr.-M v Dealer July 15, 2019 Municipality of Anchorage Development Service Department On-Site Water&Wastewater Program 4700 Elmore Road Anchorage, AK 99507 Ref: Proposed Septic System Upgrade for Denali View; Block 3, Lot 6 To whom it may concern: The existing 5-bedroom house is served by a private well and septic system. The bottomless IDSF is in a state of failure and needs to be upgraded. We are proposing to re-utilize the existing 2,000-gallon STEP tank and re-build the IDSF. We are proposing to excavate out all contaminated material, import MOA approved sand as needed, and re-build the existing drainfield at a higher elevation. It should be noted that the existing IDSF was given a 3 gpd/ft2 soil rating, even though only a soil rating of 2 gpd/ft2 is allowed. Using an application rate of 2, the re-built bed will be undersized by 15 ft2. We are requesting a variance that your department allow for either the use of the application rate of 3 which was used previously, or to allow the drainfield to be slightly undersized when utilizing an application rate of 2. Comments regarding the design are summarized as follows: 1. SOILS: See the attached 2000 soil log by Mike Anderson. P.E. which shows the soil classifications, groundwater monitoring, and the percolation test results. 2. DRAINFIELD DESIGN: See attached design drawing for drainfield specifications. 3. SURFACE WATERS: There are no surface water concerns. 4. TOPOGRAPHY: As can be seen on the attached design drawing, the average topography around the proposed drainfield is less than 10% running southeast to northwest. We are unaware of any adverse impacts this installation would have on adjacent wells or septic systems. If yo have any questions, please contact us at 337-6179. Thank you for your assistance. S :rel 41 Jeffr_r ' . arness, '.E., M.S. Pre d_ t 3701 East Tudor Road, Suite 101 *Anchorage.Alaska 99507-1259 Phone: (907)337-6179*Fax: (907)338-3246*Website: www.garnessengineering.com I DENALI VIEW;BLOCK 2, DENALI VIEW;BLOCK 2, DENALI VIEW;BLOCK 2. DENALI VIEW:BLOCK 2, LOT3 LOT4 LOT5 LOT6 ,44 > A 41*• . /.. 44 700.E ( 100'WELL RADIUS R9p/ps 1 ' I 100'WELL'•DIUS iP. D IEW.BLOCK 3, SULT• NA DRI TirMigial L. 10 millir VACAN 100'WEL -� IIIIIIIIIIIWIIIIIPraIPIr v L RAD DENALI VIEW;BLOCK 3. 00• LOT 9 \ • IF 4411111111 111111111" K> *To, -1000•. ...0-14KN 111.1* 11116 100'WELL RADIJS ' �•0' Y DIUS lir /// • DENALI VIEW;BLOCK 3. D t LI IEW;BLOCK 3. DENALI VIEW:BLO 3. LOT 7 LOTS 011rV, D. ALI VIEW;BLOCK 3, LOT 8 110'WELL RADIUS SCALE: 1"=100' — ...._� n — - L , oma4. A� " * : . � 'GARNESS ENGINEERING GROUP, Ltd/: • . ENGINEERING SALES CONSULTING 3- • • 0 3701 E.TUDOR ROAD,SUITE 101'ANCHORAGE,AK 99507•PHONE(9071 337-6179•FAX(9071 338-3246'NEBSfTE:www.gamessengneenng.com 0 • ••• It. • PREPARED FOR: PHONE NUMBER PAGE NUMBER: : Jeffr A. G ness : 1. STEVE& SHARON MARSHALL 301-8047 1 OF 2 #j0 .� C 53 ��� PROJECT/LEGAL DESCRIPTION: DRAWN BY: ��`P�'' �\,: DENALI VIEW: BLOCK 3, LOT 6 PNB ���f'F�'•7 �: (• ''••�•�'i• TYPE OF WORK: DATE: ♦41 pROFESS\c ♦ SITE PLAN 7/15/19 LICENSE ��-Vi„"..10♦ #AECC884 7�, GEG,Ltd.HAS AN 8 PAGE SPECIFICATION LETTER DESIGN CRITERIA: THAT PERTAINS TO THIS DESIGN.BY PROCEEDING NOTE:CONTRACTOR SHALL HAVE ALL WELL RADII FORWARD WITH THIS INSTALLATION,THE NUMBER OF BEDROOMS:5 SHOWN ON DESIGN DRAWING AND THE WEST LOT ENGINEER,WELL DRILLER,CONTRACTOR AND GALLONS PER DAY(GPD):750 GPO LINE FLAGGED BY A REGISTERED LAND PROPERTY OWNER AGREE THAT THEY HAVE PERCOLATION RATES:*29 MIN/INCH SURVEYOR. READ THESE SPECIFICATIONS AND AGREE TO PROPOSED APPLICATION RATE:"2.0 GPD/FT' ACCEPT THE TERMS AND CONDITIONS OUTLINED. - MINIMUM IDSF SQ.FT.:"'375 FEET' *PER MIKE ANDERSON 2000 SOIL LOG "PROPOSED IDSF "REQUEST FOR VARIANCE ON REQUIRED FT' DRAINFIELD DESIGN: • MAXIMUM DEPTH:LIMITED TO REMOVAL OF CONTAMINATED MATERIAL WIDTH:12 FEET LENGTH:30 FEET SULTANA DRIVE M.O.A.APPROVED SAND FILTER:2 FEET EFFECTIVE:0.5 FEET(MINIMUM) 4 i iiiiillirrIDSF FEET':360 FEET' i//////////////////////////////////ir 11666., 100'WELL RADIUS .IV NG 72\e,,,,, r" 7 114 t DENALI VIEW EXISTING AIRLINE TO BLOCK 3,LOT 5 BE RE-UTILIZED \.,;,. INSTALL FCO IF ONE DOESN'T EXIST ��� EXISTING 4 � • MT BEDROOM HODS 0016* •7. '. I EXISTING 2,000 ALLON STEP •+•�•"�,••• TANK TO BE - -UTILIZED• EXISTING IDSF 12'X30' +: ...... • ` •'' tea••; .•. BED TO BE RE-BUILT '-•••".••' ''j°• ••••.:•4) ':••• \?,1 ',•i`, `-Z• DRIVEWAY \Q �••i••.•..Itr )k S ALE: DENALI VIEW;BLOCK 3,LOT 7 1"=40' GARNESS ENGINEERING GROUP, Ltd •• - ENGINEERING•SALES•CONSULTING % • ,••3701 E.TUDOR ROAD,SUITE 101•ANCHORAGE,AK 99507•PHONE(907)337-6179•FAX(907)338.3246•WEBSITE:www.gamessengYleming.com • PREPARED FOR: PHONE NUMBER: PAGE NUMBER: ,0 J: ' A. Gar -ss STEVE&SHARON MARSHALL 301-8047 2 OF 3 ♦j�p•••• C.--•s .•:' =� PROJECT/LEGAL DESCRIPTION: DRAWN BY: #. �, DENALI VIEW; BLOCK 3, LOT 6 PNB ♦♦ •�•••''� •(b •�0:0*(e, '4,0 TYPE OF WORK: DATE: 440 FL. *) 444 LICENSESEPTIC DESIGN UPGRADE 7/15/19 #AECC884 1�'��'��� i 3/4"DIA.SCH.40 PVC LATERALS (HOLES,SHIELDS,AND FLUSHING VALVES PER ORENCO DESIGN) 12'x 30'BOTTOMLESS IDSF. EXISTING AIR LINE COIL / i I I 1 1 1 • / 4 I 1 1 { I 1 I 10 1 I 1 1 1 1 I 1 I 1 1 1 1 �O 1 { , , , V I 1 V I J Q cv \ 1 I 1 1 1 :ORATE: 111IIIAQI1IiIIIIII1I •IqI30 14"DIA.MONITORING TUBE AT EACH FLUSHING VALVESEXISTING DISCHARGE LINE CORNER PERFD BETWEEN TOP (WITH PROTECTIVE COVERS) FROM STEP TANK AND MANIFOLD OF SAND AND DISTRIBUTION PIPE (EXTEND ABOVE GRADE) INVERT.(DRILL 1/4 INCH DIA HOLES) MINIMUM 2'+OF COVER 9"OF WASHED PEA AN ALARM FOR THE AIR GRAVEL MEETING PUMP MUST BE INSTALLED MOA IDSF SPECS MT FILTER FABRIC MT fINSULATION 37 S(OQF •••i•i•'•i i•i••i•i•:•i•i•'•i•i•i•+• 4•i•i•i•.•i•i•i•i•i• •in •ice'•'• REMOVE CONTAMINATED PEA -- �' ` `�'°�' ��sa'r. r"'''erg •t'u" GRAVEL AND SAND �?•r+4`'S.. is Y'3;`'F` �+'.3A �3.�+X,... .< '�y,s INVERT OF PIPE=0.50'ABOVE TOP OF SAND EXISTING AIRLINE '4"•"''y l'='.�'4}r•:•� -c417.1i- '='.� "� •:;',. N V.4.�'•A-F"Y' TOP OF PROPOSED SAND=0.1' N4••'A Y.•f.=K•i:;�•,9. . HIGHER THAN EXISTING SAND 12 FEET 1 LIMITED TO REMOVAL OF CONTAMINATED MATERIAL TOP OF EXISTING SAND NOT TO SCALE dk�%% %%al .4 I 1 � • 1 GARNESS ENGINEERING GROUP, Ltd 9 / �'�'� �: Fa.........._ ��� ��CIVIL&ENVIRONMENTAL ENGINEERS -a - 0 •��•• 3701 E.TUDOR ROAD.SUITE 101'ANCHORAGE.AK 99507'PHONE(907)337.6179•FAX(907)338-3246'WEBSITE:www.gamessengneering corn %.. • PREPARED FOR: PHONE NUMBER: PAGE NUMBER: • J •• A. -•S i z-Li/ STEVE& SHARON MARSHALL 301-8047 3 OF 3 �• - Er/7913 _‹a PROJECT/LEGAL DESCRIPTION: DRAWN BY: ..v/s, . •*CD'ar j' DENALI VIEW; BLOCK 3, LOT 6 PNB �1 .. �r• �'T• _�'.� TYPE OF WORK. DATE. ♦�� �'ROESS\ P�• IDSF DETAIL 7/15/19 #A CC 114��'I" Anchorage Tank&Welding,Inc. Intermittent Sand Filter SAND FILTER CONFIGURATIONS 30. - 50 MIL PVC LINER 12" ORIFICE 5NIELD �a`�,p--() - -0_ -�'-_�Owl 0- 0 60 50* FLU5WN6 VALVE 90x >0 a 4 0 a 0-- 0 0 0 '-0---0 0 0 FROM 5 T E p. ---,G / C GAP S"'5177`. ... D15CNAR6 a \\...0 --TOAILINE SE LIN _..) 12' 4'CLASS 125 SLOTTED PVC PIPE(1/4'?NOE SLOTS 2-1/2' - .• ... ....•.. .. •. •--. • • O DEEP AT 4'04) FROM AIR y COMPRft 3/4'PVC;.ATERAL 0,-._-�__.0_0---- -,•=.---=6-..4' (w/I/5'4,ORIFICES) I-I/4'PVC MANIFOLD TOP VIEW 12 x 30 SAND FILTER w/GRAVITY DISCHARGE Page 37 PLAT NO. 76-211 DENALI VIEW SUBDIVISION LOT 6, BLOCK 3 42,115 S.F. ---' pR�vE �, SU�Tp,NA G LA C 2` 7 R_gg6.73' 1.. 211.20' n WELL J, OG\ (1igi , 50• ...c.o. *Cr! O ck O Igo VA tW '0. o N. x1 v,;K 110 0,$,•` ` o `C •o. N 115: u. \�cOG $ ,5 xc,'` �o • • �1° o d g.Y G 8V . F• • l' �t . 1•P cls ��N �3` O. . SEPTIC SYSTEM f • ��`S rn `6°� `1S.4141`�1 6,O '. 76.3' • 3 1� �� i i X X35 K / o. o ,, / / . 11° / b 90.2' �"° a r i N i �C*oR a i v 0 i o i o z i i 11 i �`'t'• 4)G.5. / � od �p ' P' M V Vy o r v i i 1 " = 30' AS -B U I L T I HEREBY CERTIFY THAT I HAVE SURVEYED THE ���' p'• q*♦ GASTALDI LAND PROPERTY DEPICTED ABOVE AND THAT NO .� ♦ ENCROACHMENTS EXIST EXCEPT AS INDICATED. G' .•.• qs, ♦. SURVEYING. LLC IT IS THE RESPONSIBILITY OF THE OWNER TO a JEFF A. GASTALDI, R.L.S.al *: 49TH *\ v*.. 2000 E. DOWLING RD.. SUITE 8 DETERMINE THE EXISTENCE OF ANY EASEMENTS, • ./ COVENANTS OR RESTRICTIONS WHICH DO NOT •� �'0a .0 ANCHORAGE, ALASKA 99507 APPEAR ON THE RECORDED SUBOMSION PLAT. Jeffery A. Goslola� •: o a PHONE 248-5454 UNDER NO CIRCUMSTANCES SHOULD ANY DATA ♦ 4, �.• 7/12%2019 e " GRID DATE HEREON BE USED FOR CONSTRUCTION OR FOR •♦♦PdA� ••••••'•'eo�e`'J�.� SW2741 7/12/2019 ESTABLISHING BOUNDARY OR FENCE LINES. ♦♦;fess�ono�;'�� ANCHORAGE RECORDING DISTRICT, ALASKA 1■W1 F.B. JOB NO. 00-13 DVS63 NOTE : NO CORNERS SET THIS DATE Municipality of Anchorage Pa~e. I o! 3 · DEPARTMENT OF HEALTH AND HUMAN SERVICES ENVIRONMENTAL SERVICES DIVISION P.O. Box 196650 ~, Anchorage, Alaska 99519-6650 · Telephone: 343-4744 On-Site Wastewater'Disposal System and/or Well Inspeclion.Repod, .-. ..: . Pe'rmitNumber: SW000029 ' ' ' · PiONumt~r:. 015-461-07 ' ".. '~""": " ..... '" ...... · ' ' ' .... Wastewater S~,s{em:'.' 0g New'~ ' O upgrade crown Pointe/:jI~6. ' ' '. · · ' :. PiO.'.Box'.112313 'Ankh.',' 'A]~.':9'~511'. '":'. : ·':ABSORPTION FIELD.. :.:..'.. "~" · ....... '.'." . .... . '.I,o.,"B~,oo-~ .... · '" · ..... ,;'' ~". o~d..o' "' ' ,o~,d'm~,~,.'" '"' .34526277 .-....v.;.' =' i. '. I Five..(5)' .. ODeepTrenc.h ,OSha!° Tren~. ' .: %?'. LEGAl:DESCRIPTION .':.: . --:.. cot : "" "i "' ~ ' '" ' ."5 ' "J'"? ' 6'~<,.:."'?'.:<~:,::'.."3"~:.'. Dehali.'Vie~.': "~ . .. "':.'.':.'1 ;5%-.':.:.. ,~,.! ", ".' - -. "~'::'.',i' ...... · · .... "· I ...,- .-, · .... . ..~.. , · · ....... ',:; ...... - 7 '. ' ~ %.~,.r6 ';~'.~:":.',.~'30':'..''.<'.''c:'~'F~.' · - ' -..,....... . . . .. . ". · '...,.. ..W..E..L.L~;.<~::..,:.., ~e..w,,..~:,...,.,:~,.u. pg..~.d.?.....~..,:<:.:..~., ::'...' ,.-: .'-, :.,: ::..~ 2.: ?',': .-'.-:.:r~. ..'~-:..d[..'.-.~.h.-: .: .'..:2.'...:.~ :. :,: · :,, .: ,..360. ., s~.rt Anch;.:.Tank:':,Kit:,:'.'.- · ...f.Tr~.~a'te..,:~;.:..:.~!...,'.:-.h:..~:.:- ~:-.:~:;22'6'r~;.,~.,:,-.2o.. r~ .......... -2... , .... -'%Al~in'e{Dr~!ling%"':r~4~70,.0...:,~3~::::~': San'd~rs..& ?Sand6r~ Y.~4:..:,..,,',; ,.::.,.'..,:-I~ump.~tat. ~.;,: , .:,', IC3=~j~tAt)o~ ~ - : ..... ; ' ';--' ',. ~ ':' ' ' "'" v~ '?".r:, - '.- . ...... '.'. ": '-'.4 ':'"'<'::':'<". ' ' :'.:~<<':..':.:...-..'.:';, · ~_ '..~z :' .;" · ' ........ . ..... ..TANK .... . ......... .., ..... . ..... :~.c~I ........... ? ....... r~I .......... ,.~.~ '.: .- :'. . :.' ·., . ~,.::" :. :.'-.:: .'-... '":'"'"";"<SEPARATION 'DISTANCES:' ?"": .... ..... :"' '" '"'"' ~ ....... ~<" ""' ......... ~' "' .... ::]Sept C' . -.,: '.:. [3Ho~,n~.: ....... ~:]S.T.E.P. ,. ~.-.. '-~., .t..-:,:.. , %...:~.~?j ............. : " " .... '' ' ~,o~...:' ' "'. ,~,.:'" ' ' -" t~.~': ;...r.;~' ': ':~:: - .... · T~, .. S,~,~ :Anchorage.<Tank'. :./'. /. 0~.STEP.'.. ::'1': i :,V:.. :~NZ~..:'i : $.~eel :.:/.'.':.:,:..,,.,,,<-:....<., ;..~""~'ee','.' ,;:. %'. . - :..:.-: ;, .?.".'w~...:;:.: .5.':lO0~,~:-1.00':b:l,0O'.'...... -.' u.~, -:::.-,,.'. '...:..?<,:,-~'~.~'. .... , '.'"'" '"',' '/-" .:..su,~c,.'.,' ~:1'6d ~ .>.1 00. >1,00- ::'N ~,~: J'...':'"'":'.... ::".... :'""~"':~, ...... EIF'F'STATION ....... ..~ ...~t..-..,.: ..... .. ~......,,::. · ,~;~Wate~ ,~':~ .". '." ', :' ..... - ~- : ~ ................. ~'~':Lot::.:;Sf:' ~.~. 't%.-'~!_,,,...,/ ..... : · ~..;....-i'~:' . .... .. .... '." S[z~'i~of~,: -IM.~-tur~.:' .',; ."- . :..,.'.-...?.'.'>'/'~,'-?;.~.< > ..,~-u,~. ~'£ ~1 .0':: ,~5. .... ,'- :'iNCA'; >.N/A'-' 500 ".:-: ....; I Anch~':Tan'~/O~e~Co.'.:.',.;/.',.-v ............ ,, .2:: ' ~0~':: '" ...... ':..'~:,' ': "' ~" ..... . ...... >.5~. ', :~,'10~: ';~]'ZA;'", ...... ... .......... 42 ....... . ...... I-..42 .... .., .... I..44 ........ .... .... Orenco,. ;-..Mun J,,;: ' ~ r.. Ancn.,,';; .~ ~e ' ~epo~ · :.::Dr~.:,~:~ Non6:: ~bfe~.!O~'~ ., ." ....... .............. . ............ · ........ ,, :i,..,7,:~-~'~'.';~..~' ~,.. ....... .. .... .. :.... ....... ~...,<....~.,.,.._.,~. ...... ...., ....... ,, ... ....... ,j ..~ .::.,. ;.:.,..:: BENCH:MARK Remarks:,'.:,.-A i r r 'Comp re s s o r ::an c~ ::G a u g e ?:-<Locatec~ .in .Garage;. %,: ~, ,',- ;~;- ...... · ;'%7'.'- ?.:,.., ~.?:..--' ..~ ,, <r., ,"~." ~..:{~..' ~ '-', S'.,. =,,,.,':-'.,..,..., '.-. ',,,...',; :.'...,,','":';', ,..,,'.~'~ ..~ .,..~. .,..:, ::-:.<.?..,:: ,:~...-..?~,.... ~r'~.l ..... · ,., .,,-100.0,,-. ~.....-, ~ ::~. :.,, ./.=.~: -.. ,';..;.:,?. :..; · ~:.: iT::,.,:.; ..,.?';. ::;.,":i'~.;,,~, ~..~.'¥;' ..t.::,: :::,%.~.:~. 't:;"~'!:;,~ ?'L :?,:: ' '~ :~.';t,~.rdg~J~l~'~"~EAL'~','.:-';.' ,: ;, : .~'~ ...... ~, !. ~,,...,.<: ..... ' ,',. L~. ,: -:, '-~'..~. ,-...,-.J,> ..,r ..... ~-:'..:-.' ' · ... ..... . .... ......................... ...... .............. . .................... ~ .,~, ...... ~:~{~.~..... · ~,'- ...... ?.--... ,.--,-,~,.-,~..-,,~:.? ..... /~,-~ .. ,.,.~..... ......... .-', ,. --,.~-.~- ~":f~,~.'.. ~:(,~,<~.~,-.,~,~..~A' .... :..::., .:. ..., ,.:; ...... ,: ,., , . . ..... , ........ ..... , >,.. .'-"-' :.--'---.:'., ,,h..,..~..', ~. ~..., ,-,' < .-. ,---....!:-.--,,. ~.". :,-'..-.... .... .,,: ...-,.. ....... - ~ ::"Z~,~ ~'~ :-..':'::,i~ 0 ::lnspechons perform%"d bT. :~: '.-" :"'< ':~'-";"- '-"". ':' ' "': .... :~'.-- --~ '~ <~nd '4/29/00.~, ....... ..... .... ., .................. :"',':. Department of Health and Human Services approval.: ,'<. ,~-~,~-,.,'"; ~.. ,.-:~<'-.',.-.: ¥~. <~,;~*~V~ .... , ;, ~,~r,~,,.... '-... '...,.'.~ .-:.': ".;~~ ~;~. ' · · . ~,' '. ...... ',' ~;r,0&.,' -~.%~t~.Y_~..' ...- :............. . ..: . .< .... . ..... .: ........ .~: ....., . .. ,.' .. ., :~,~:,~,~.~.'~- .... .......... ~,~"~ :.:: . . . ,_ ...... ..... ._ ...... ..... Municipality of Anchorage DEPARTMENT OF HEALTH AND HUMAN SERVICES ENVIRONMENTAL SERVICES DIVISION P.O. Box 196650 - Anchorage, AK 99519-6650 - 345-4744 On-Site Wastewater Disposal System or Well Inspection Report Page 2 of 3 Permit Number SW000029 PID No. 015-461-07 ~+~?nase'; ' ,I :"\ ~' '.'~' .':. , ... "'..'. ; .:'... -. '.'...'- ,\" -..:...~'.".,... =..:.;'C~L; .""..: '.'.. '.-. : .\ \ '. ' '- ' · . -'~-' .'..:.'...' · ':. ' ~ -.'.. .' .... ..: ...... .- "'' .:''V.' · ' \ ". : '' ,'..' ."'' -' ..... '" ~ ' '. '.': ..... 'I'4H~.~ k .... '-" · ~·=' "'...'. "'.'; · '" '-~('~-' ".'. ' :'"L ' "~"' ;' ." ' -",' --."~.l :.~' ' ·'"' ~"-'.'...' ' ."- ' · '.., \ \·'.:'¢ .-'! ". '.':.'.': '"' .. ' ....:.:.~.:..'. i. .'/ ":": ~. :":: : ; '.?. : .:'.'.'. ..:. '~:".:':..":i ;"'::.': "...." · .. .., .. / ..... - .... .:...., ,.. ....-!., :. --... · . ..~. A B S1 23.0 45.5 S2 17.1 55.3 MH 17.2 57.5 M1 30.0 68.0 PLAN Municipality of Anchorage DEPARTMENT OF HEALTH AND HUMAN SERVICES ENVIRONMENTAL SERVICES DIVISION P.O. Box 196650 -Anchorage, AK 99519-6650 -343-4744 On-Site Wastewater Disposal System or Well Inspection Report Permit Number SW000029 PID No. 015-461-07 Page 3 of 3 "0" ~ 2,000 GAL. 88. STEP Tank '87.4 85.3 . 96.2' :. ' Flushin~ '/" . - Valve 'Geotextile Fabric 2' Ftlter'San~ I · 30' ' ' '1 ' ' 6" of.3/8'~ Pea... Airline '- ' ",.:[ ' ': - -',,..T.: ................ Municipality of Anchor. age Department of Health anti Human Services 825 'L' Street P.O. Box 196650 Anchorage, Alaska 99519-6650 Rick Mystrom htr p://vnvw cl anchor age.ak us Mayor Permit Number: #SW ..p00029 Date of Iaaa," .3-8..00 .Parcel J,h'ntifleation .Number: 015-461-07 Date Started: 4-5-00 Dale Completed: 4-6-00 Is well located at approved permit location? [] Yes [] No Legal Description. Denati View blk 3 It 6 Property OwnerName & Address: Crown Pointe INC. PO Box112313 Depth (fl) Method of Drilling [] air rotary [] cable tool From To Casing type: steel Borehole Data: Soil Type. Thickness & Water Strata stick-up Gravelly silt BedroCk 0 2 2 13 13 226 RECEIVED flOV 29 2000 Mumc~pality ot Anchorage Oept. Health & Human Services Wall Thickness: .025 inches Diameter: _6 inches Depth: 20 feet Liner Type: Diameter: inches Depth: .~ feet Caslng stickup above ground: _2 feet Static water level (from ground level): 13 feet Pumping level: 226 feet after _2 hours pumping _4 gpm Recovery Rate: _4 gpm Method of Testing: airl~ Well Intake Openlng Type: [] Open End [] Open Hole [] Screened Start feet Stopped feet [] Perforations Start feet Stopped feet Grout Type: bentonite # 8 Volume: I bgs Depth: Start 0 feet Stopped - feet Pump: Intake Depth feet Pump size hp Brand Name Well Disinfected Upon Completion? [] Yes [] No Method of Dislafection: clorine tablets Comments: Well Driller: Alpine Drilling & Enterprises PO Box 110496 Anchorage, AK 99511 A'ttemim~. 'Th~: weal drillet'shali vtovide a well log to the property owner w{th;,, 30 days of completion and the property MUNICIPALITY OF ANCHORAGE Depa~ment of Health and Human Sen/ices On-Site Services Program 825 L Street, Room 502 P.O. Box 196650, Anchorage, AK 99519-6650 (907) 343-4744 ON-SITE WASTEWATER DISPOSAL SYSTEM I WATER SUPPLY PERMIT Initial Date Issued: Mar 08, 2000 Expiration Date: Mar 08, 2001 Permit Number: SW000029 Legal Description: DENALI VIEW BLK 3 LT 6 Design Engineer: 0014 Anderson Engineering Owner Name: Crown Pointe, Inc. Owner Address: PO Box 112313 Anchorage, AK 99511-2313 Parcel ID: 015-461-07 Site Address: Lot Size: 42115 SQ. FT. Total Bedrooms: 5 Permit Bedrooms: 5 This permit is for the construction of: [] Disposal Field [] SepticTank [] Holding Tank [] Privy [] Private Well [] Water Storage All construction must be in accordance with: 1. The attached approved design. 2. Ail requirements specified in Anchorage Municipal Code Chapters 15.55 and 15.65 and the State of Alaska Wastewater Disposal Regulations ( 18AAC72 ) and Drinking Water Regulations ( 18AAC80 ). 3. The engineer must notify DHHS at least 2 hours prior to each inspection. Provide notification by calling (907) 343-4744 ( 24 hours ). ( Not required for a Water Supply Permit only ). 4. From October 15 to April 15, a subsurface soil absorption system under construction during freezing weather must be either: A. Open and closed on the same day. B. Covered, sealed, and heated to prevent freezing. Received By: Issued By: MUNICIPALITY OF ANCHORAGE Department of Health & Human Services On-Site Sewer/Well Permit Application Single Family Dwelling Property Owner Name: Crown Pointe, Inc. Mailing Address: Legal Description: Lot Size: ./~,~//5 Number of Bedrooms: Day Phone: 345-6277_ P.O. Box 112313 ' Anchorage, AK 99511-2313, _ Lot 6, Block 3, Denah View Subd,v,s,on ~--~/- ~'~ ~'~'~ ..Square Feet ' Inspections will be conducted y: Five (5)' X Approved Engineering Firm "Municipality (permit fee included) . . Does your house contain any of the following: Hot Tutti Swimming Pool, 'l'~erapy Pool, Jacuzzi, Or Water Soflener Unit? No Ifyes, whichone? This Application is For: Sewer Only Sewer and Well .XXX Sewer Upgrade Well Only I certify that the above information is correct. I further certify that this application is being made for a Single Family Dwelling and in accordance with applicable Municipal Cedes. Engineer Fees: ' ~/~x'//'~' ~ O Receipt# RECEIVED · ' I AR 0 2 2000 MUNICIPALI[¥ OF ANCHC~RAC~I: ~ 'm*"~IMENTAL ,SER¥1CES DlVle' ANDERSON ENGINEERING P;O. BOX 240773 ' ' ANCHORAGE, AK 99524 ·. "' 522-7773 , 522-6779,(FAX): MEMORANDUM DATE: March 8, 2000 TO: FROM: Dan Roth Mike Anderson, P.E. "~/[~1~-~ SUBJECT: Lot 6, Block 3, Denali View Subdivision . . · . . Septic System Design 'and Construction Permit I have modified the affected pages of our original permit request to reflect'a piping' depth of 1:5' to 2' below existing ground. I have also changed the number of monitor tubes required from 4 to 2. Please replace the sheets previously submitted with those . attached. Thank you for your assistance with the design of this system. . . I ANDERSONENGINEERING . *': ' ~ 'P;O; B0~-240773 ' : , ::.I .. ".::..: ~NCHOR~G~E'; AK 99524': ','" Mar~h 1, 2000 Municipality of Anchorage Department of Health and Human Services 825 "L" Street . Anchorage, AK 99502-0650 · - 'Subject: Lot 6, Block 3, Denali View Subdivision Septic System Tank Replacement Permit Applicati~)n Impacts to Adjacent Properties · Dear Onsite Services Engineer: The :owner (~f Lot 6, Block 3, Denali View. Subdivision intends to construct a five bedroom home on the lot. We are therefore applying for a permit to construct a well and septic system to serve the house..The Site Plan shows the location of the new system with the alternate site. It also shows th.e Iocati.o.n of the p. roposed well and the 100' protective.radius. Additional information Is submitted showing the location 'of all wells and septic systems on the surr0undiqg lots. - ' The testholes placed on the lot revealed silty gravel which percolated at rate ranging · ' from 20 to 30 minutes per inch. No groundwater was encountered nor was any noted during the monitoring period.. Bedrock was enco.u, ntered, however, at depths of 12.5'. We have therefore designed a bottomless intermittent sand filter system to dispose of : the septic effluent generated in the house. The distribution pipe will be placed at 1.5' to. 2' below the surface and the total depth of the system will be 3.5' from odginal ground. The system will be a minimum of 8' above the bedrock layer. The ground surface on the lot slopes from south to north at varying grades, but none greater than 10%. The new absorption bed will be constructed across the slope in accordance with Municipal requirements. Surface grading will be accomplished to assure drainage is away from the finished bed surface.. Efforts will be made to protect the bed from surface runoff water. . All wells in the area are more than 100' from all elements of the proposed septic system. In addition; the well proposed for the lot is also more than 100' from any sep. tic system in the neighborhood. If the system is constructed in accordance with our design the following statements apply: - - 1. The system, if constructed as designed, wiil have no adverse Impact on the wells in the area or those to be constructed in the future.. The subdivision is currently served bY the Municipal water system. The system, if constructed as designed; will have no adverse Impact on existing Lot 6, Block 3, Denali View March 1, 2000 Page Two ' - septic systems in the area' or those to be constructed in the future. 4~ The system, if constructed as designed, will have no adverse impact on reserved space, either surface or subsurface, on any lots located in the area. The system, if constructed as designed, will have no adverse impact on drainage patterns in the area. The current drainage pattern will be maintained. Sincerely, Michael E. Anderson P.E,' -Attachments .4 'THIS PROJECT "7 · AREA MAP SCALE 1" = 100' 500 5OO Proposed Well 2,000 Gall STEP Tank ~ HDPE Air Lin'e 12' Wide X 30' Long F~ Bedroom ~ouse 'FF E1~07 au~e Mou e n ~ara Bottomless -Intermittent Sand Filter (See Details) NOTE: Air Compressor Shall Be a Thomas Industries Model 5070 As Supplied By Anchorage Tank. Compressor Shall/ Be Located in the Garage Along WI A 0-10 PSI Pressure Gauge ~oun~ For Ease Of'Viewing. . Air Line To Be ~" HDPE With ~ Foam Pipe Wrap Insi~ chedule 40 PVC. Jacket. 3". / 510 ./ LOT 6, BLOCK 3, DENAL! VIEW SUBDIVISION DESIGN. FACTORS: 5 Bedroom Home Perc. Rate: 29 MinJInch Application Rate: 3 GPD/SF SYSTEM REQUIREMENTS: Bottomless Inter. Sand Filter 2,000 Gallon STEP Tank 2' Coarse Sand (See Spec.) Air Supply Line (Anch; Tank) 6" of 3/8" Pea Gravel 5 Bedrooms X 150 GPD = 750 Gallons Per Day 750 GPD/3 GPDISF 112 LF (Width of Bed) = 21 LF Length of Bed Therefore: Construct a Bottomless Intermittent Sand Filter System I 2' Wide X 30' Long. Distribution Piping to be Placed at 1.5' Below Original Ground Surface. A Mini~hun~'"o~ 2;'~f"'Cover Re'q'uii'6d Over Bed. ViEW NOTE: Grade Area to Drain Away.' ~~E~'~.~ Maintain 6' Separation From Bedrock. ~;~... Provide 4' of Cover or 2" Insulation and 2' Cover.*~. ..t~ LOT. 6, BLOCK 3, DENALI VIEW SUBDIVISION · DESIGN FACTORS: 5 Bedroom Home Perc. Rate: 29 MinJInch Application Rate: 3 GPD/SF SYSTEM REQUIREMENTS: Bottomless Inter. Sand Filter 2,000 Gallon STEP Tank 2' Coarse Sand (See Spec.) Air Supply Line (Anch. Tank) 6" of 3/8" Pea Gravel 5 Bedrooms X 150 GPD = 750 Gallons Per Day 750 GPD/3 GPD/SF 112 LF (Width of Bed) = 21 LF Length of Bed Theref6re: Construct a Bottomless Intermittent Sand Filter System I 2' Wide X 30' Long. Distribution Piping to be Placed at 1.5' Below Original Ground Surface. A Minimu~ of 2' of Cover Required Over Bed. N~WAY N g~ ~ · Direct ' Bury =;U~ Insulatior NOTE: .I · PROFIEE VIEW BO~OMLESS SAND FILTER DETAIL~~~/'~ (NO SCALE) ,~~ · ~ . . .~ Grade Area to Drain Away. Maintain 6' Separation From Bedrock. ,rov,** 4' o, Co.e, o, =" ,..u,=,io. =.* =' Co,=r.-~;~~C~ Perforr~ed For: Legal Description: Municipality of Anchorage Department of Health & Human Services 825 L Street, Anchorage, AK 99502-0650 SOILS LOG - PERCOLATION TEST Crown Pointe Inc. Lot 6. Block 3, Denali View Subdivision ~LOPE 3 4 7 1 11 13 14 16 17 18 PTIOL Testhole Number GM Cobbles 1.5"-3" Was Groundwater Encountered? If Yes, What Depth? Depth to Water After Monitoring Date: Bedrock See Site Plan No S L O None P 311/00 E Reading Date Gross Net Depth To Net Time Time Water Drop 1 23-Feb 4:30 3" 2 5:30 60 5.88" 2.88" 3 5:31 3" 4 6:01 30 4.06" 1.06" 5 6:31 30 5.12' 1.06" Perc. Rate: 29 Min./Inch Perc. Hole Diameter: 6' Test Run Between 4.5 Ft. and 5.5 Ft. Comments: Testhole Presoaked Prior to Percolation Test. Performed By: ~ I, [dichael E. Anderson Certify That This Test Was Performed In Accordance With All State and Municipal Guidelines In Effect On This Date: 3/1/00 ON-SITE WASTEWATER DISPOSAL SYSTEM CONSTRUCTION AND MATERIAL SPECIFICATIONS SUBJECT: LOT 6, BLOCK 3, DENALI VIEW SUBDIVISION GENERAL: The scope of this project includes the procurement and placement of a new 2,000 gallon combination septic tank/lift station and pressure distribution system, Work also includes the construction of a new 30' long x 12' wide Bottomless Intermittent Sand Filter. A minimum of 2' of coarse sand material meeting the attached specification must be imported and placed in the filter area. The filter must then be constructed atop the imported material. Distribution piping must be placed 1.5' to 2' below the existing ground surface. Construction shall be in accordance with the approved site plan, design drawings, Municipal Permit with any special provisions or conditions, and all applicable State and Municipal Wastewater Disposal Regulations. 3. The Contractor shall be responsible for obtaining all underground utility locates and for the layout of the septic system. Unless specifically agreed otherwise, the contractor shall be responsible for final grading areas subsequently depressed from soil settling. The property owner shall be responsible for revegetation of affected areas unless specifically agreed otherwise. Contractors installing wastewater disposal systems must be certified by the Municipal Department of Health and Human Services for system installations, Owners installing their own systems must receive prior approval from D.H.H.S. before beginning system installation, SEPTIC TANK/LIFT STATION INSTALLATION 1. The 2,000 gallon septic tank/lift station is to be constructed by a certified tank manufacturer. Construction shall include an 18" manhole for access to the lift station. The septic tank/lift station shall be sufficiently bedded to prevent settling or shifting of the tank. Lot 6, Block 3, Denali View Subdivision March 1, 2000 Page 2 3. All standpipes shall extend a minimum of 12 inches above final grade. 4. Septic tank/lift stations installed without 4' of cover shall have a minimum of 2" of direct burial insulation. A foundation cleanout shall be installed one to four feet from the building foundation. No cleanouts are required between the lift station and the drainfield in a pressure distribution system. 6. Final grading over the septic tank/lift station shall be such that a positive slope exists away from the septic tank. ABSORPTION BED CONSTRUCTION: 1. The absorption bed shall be constructed to the dimensions shown on the design. The bottom of the bed shall be within 2' of level. Distribution piping must be placed level with perforations down atop a level bed of drainfield rock. Rock should then be placed over the pipe to provide a minimum of 2" of cover. 3. A silt barrier or geotextile fabric must be placed between the drainfield rock and the natural soil backfill. Monitor tubes must be 4' in locations shown on the design. must be perforated. diameter and installed at the The portion in the drainfield rock Direct bury insulation must be placed over the distribution system when less than 3' of backfill depth is available. Finish grade over the bed must be mounded to prevent settlement or depressions. MATERIAL SPECIFICATIONS: 1. The lift station must be constructed by a Municipally approved septic tank manufacturer. An Orenco 20 OSI 05 HHF- 5 is recommended. 2. The following pipe materials are approved for use in septic system installations in the Municipality of Anchorage: Lot 6, Block 3, Denali View Subdivision March 1, 2000 Page 3 Cast iron (perforated and solid),.ASTM D3034 or PVC (Perforated and solid), ASTM F810 or HDPE (perforated, but not solid) and ASTM D2662 or ABS (perforated and solid). 3. Insulation shall be at least 2" thick extruded direct burial polystyrene (Dow Chemical Co. Styrofoam HI or equal). 4. Septic tank inlets and outlets shall be fitted with watertight couplings (Caulder, Fernco, or equal). A permeable geotextile fabric (Typar, Mirafi or equal) must be installed between the final drain rock layer and the native soil layer. 6. All drain rock shall be .5" to 2.5' in diameter with less than 3% passing the #200 sieve. EQUIPMENT SPECIFICATIONS: Air Supply Line Shall be a Wasteflow Emitterline, 1/2" Inside Diameter from Anchorage Tank. Line shall be insulated with 1/2" foam pipe wrap inside a 2" Schedule 40 PVC Jacket buried a minimum of 3' below the surface. Air Compressor Shall be a Thomas Industries Model 5070 as supplied .by Anchorage Tank. Compressor shall be located in the garage or crawl space. 3. Pressure Gauge from 0 to 10 PSI Shall be furnished and installed in the garage at a location easily accessible for viewing. INSPECTIONS: A minimum of two inspections are required by Municipal Ordinance. These inspections must be conducted under the supervision of a professional engineer registered in the State of Alaska. The first inspection must be conducted after the excavation of trenches, beds or pits and .before the installation of any gravel. A septic tank may be set in place, but may not be backfilled. The second inspection must be conducted after the placement of the geotextile fabric, gravel, distribution piping, standpipes, Lot 6, Block 3, Denali View Subdivision March 1, 2000 Page 4 cleanouts and insulation. No backfill should be in place at the time of the second inspection. The contractor assure that all area are met. is responsible during the layout of the system to separation distances from adjacent wells in the OPERATIONS AND MAINTENANCE MANUAL An Operation and Maintenance Manual for the Design, Installation and Maintenance of Intermittent Sand Filters is available from the Municipality of Anchorage, Department of Heath and Human Services, Onsite Services Program at,825 L Street, Room 502. Additional information is available from the supplier' of the intermittent sand filter. It is imperative the system be maintained in' accordance with this manual to provide trouble free service. FILTER SAND SPECIFICATION. Coarse Well Graded Sand 'Maximum 2% Passing No. 100 Seive Maximum 1% Passing No. 200 Seive : Municipality of Ancl?rage DEPARTMENT OF IIEALTII & IIUMAN SERVICES - 825 "L' Street, Andtorage, Alaska 99502-05501 ' · · PROPERTY OXVNER MAINTENANCE AGREEMENT ;... '. . ON SITE WASTEWATER DISPOSAL; SYSTEM This agreement, dated .: /~' 5" ,260_~ 'is made between the Municipality . . . ' of~Afichb~ge Department'of IIealth and IImnan Services (DIIIIS) and the property . :'. - : - ' .Owner(s) of: Lot' 6, Block 3~ Denal~ .View Subdtvtst~ · "' "': Add .... ..... : - 'Ti r' 6purp f intaini g r'dLsp . ils agreement is made fo tit oseo ma n an on-site xvasiewate os'al ..... Sy s6t;j ct p p~rty - ' .... - - - -- The property owner(s) a e'tothefoIIo : ' '" ' '' ' ' " ' ' -, . . .The pro. l{erty owfier(s) will have an annnal inspection of the ay!tern performed by :' .... - a registered professional engineer. 'This in~pectidn shall verify that all effluent'and air ' · , .' i- .. . . ~ Pump~, Ihners,~'and alarms are funcfio~fin~ as designed. Any deficic~ici~s shall b~" c :, .:' . .. '~.'"'. ~'ropcrty~fl'}ner Na~ne ,. · · . '.. :.. .' .. ..' - :':Property Owner Na~ne i J" ..:.":,'" '}'. ". "- ". , .....: .... .:'- .. ...'. : ..'".' . . . . .~ . ,..~ ,. .... Third .Judicial District '. ...... . . ..' . The fo{ego'ing instrum;,nt .was acknowledged before'me this 5th day of -. December, 2000, by.Wesley W. Clubb. ' ' ' ' ' '" ' '" ' '- · Notary Public in and for Alaska . My Co-mmis~ion Expires: "2-4-2003 '. Parcel I. D.015-461-07 Municipality of Anchorage On -Site Water and Wastewater Program (907) 343-7904 Certificate of On -Site Systems Approval 1. GENERAL INFORMATION: Complete legal description DENALI VIEW; BLOCK 3, LOT 6 z Expiration Date: Location (site address) 12300 SULTANA COURT *ANCHORAGE, AK 99507 Current Property owner(s) SHARON MARSHALL Day phone 907-301-8047 Mailing address Real Estate Agent 2. TYPE OF DWELLING: ® Single Family (w/wo ADU) ❑ Duplex ❑ Multiple Dwellings (Single Family and/or Duplex) Day phone 3. NUMBER OF BEDROOMS: 5 4. TYPE OF WATER SUPPLY: TYPE OF WASTEWATER DISPOSAL: Individual Well ® Individual Individual Water Storage ❑ Holding Tank ❑ Community Class _Well ❑ Community ❑ Public Water System ❑ Public Sewer ❑ WaiverNariance request for: Distance: Received by: Date: COSA to be released to the engineer, unless otherwise requested by the engineer. COSA Fee $/��/ Waiver Fee $ Date of Payment Date of Payment Receipt Number 4" Receipt Receipt Number COSA # 65C I37 -a Waiver # CA, 5. STATEMENT OF INSPECTION BY ENGINEER As certified by my seal affixed hereto and as of the validation date shown below, I verify that my investigation, based on procedures outlined in the Certificate of On -Site Systems Approval Guidelines for this application, shows that the on-site water supply and/or wastewater disposal system is (are) safe, functional and adequate for the number of bedrooms and type of structure indicated herein. I further verify that based on the information obtained from the Municipality of Anchorage files and from my investigation and inspection, the on-site water supply and/or wastewater disposal system is(are) in compliance with all applicable Municipal and State codes, ordinances, and regulations in effect at the time of installation. Name of Firm: Garness Engineering Group, Ltd (GEG) Phone: 907-337-6179 Address: 3701 East Tudor Road, Suite 101- Anchorage, Alaska 99507 Engineer's Printed Name: Jeffrey A. Garness Date: In conducting this evaluation, GEG provided an engineering evaluation of the well and/or septic system in accordance with the guidelines and regulations established by the Municipality of Anchorage and industry practices. The reported results describe the condition of the system/s on the date/s of the evaluation. Separation distances were measured to readily identifiable features. Hidden defects or encroachments may exist that were not identified during the evaluation. The operational life of all wells and septic systems depend upon a variety of variables, including but not limited to, soil conditions, groundwater levels (that may fluctuate during the year), quality of construction (materials and workmanship), and the water usage of the family utilizing the system/s. These conditions can vary, and are outside the control of GEG. Satisfactory test results do not guarantee future performance of the system/s; therefore, GEG makes no warranty (express or implied) regarding the future performance of the well or septic system. GEG makes no representation whether an alternative well or septic system can be installed on the property in the event either of the current systems fail to perform adequately in the future. The content of this report is for the sole benefit of the person/party that retained GEG to perform the evaluation. Reliance upon the information provided in this report by any other person or party (including subsequent property purchasers) is not authorized, nor will it confer any legal right whatsoever. 6. DSD SIGNATURE System #1 Approved for bedrooms System #2 Approved for Disapproved Conditional approval for bedrooms bedrooms, with the foll o':z=;OFq�-MA,p Je re . Gorne s: 3 � G Op 11e e ., g�1? 147 0 pro f esslo — art- A see, 0 `f ON S, rE o In St WA 0 'SNL) rn ,P wASTEWA--ct, _ ZZ J �r PROGRAM- • o` o 00 Original Certificate Date: 'l The Municipality of Anchorage Development Services Division (DSD) issues Certificates of On -Site Systems Approval (COSA) based only upon the representations given in paragraph 5 by an independent professional civil engineer registered in the State of Alaska. The Municipality of Anchorage is not responsible for errors or omissions in the professional engineer's work. 7. ATTACHMENTS: COSA Checklist Nitrate Advisory Septic System Advisory Arsenic Advisory Well Flow Advisory Other COSA Checklist Legal Description: DENALI VIEW; BLOCK 3, LOT 6 If more than 1 septic system on lot: COSA Checklist # of A. WELL DATA ❑O Well log is filed with Onsite (or attached) Date drilled 4/6/00 �pt,�lr Total depth 226 ft b11 Cased to 20 ft Lo ❑■ Sanitary seal is functioning correctly ❑■ Wires are properly protected Casing height (above ground) 18+ in. Date of flow test for COSA 7/9/19 Static water level at beginning of test 19.5 ft. Comments SEE 2019 RECORD DRAWINGS &#13 REGARDING 2003 TANK INSTALL B. TANK DATA Age of tank(s) 16 years Tank type/material SEMOSTEE Measured operating fluid level in septic tank - ■❑ Standpipes/foundation cleanout per record drawing Date of pumping 8/5/2019 D. ABSORPTION FIELD DATA NEW Which system tested (date installed) 8/1/19 ❑■ ALL standpipes present per record drawing Total measured depth from grade ft (max) Measured depth to pipe invert from grade * ft (min) ❑ N/A — pressurized field ❑E Monitor tubes go to bottom of effective. If not, state depth into effective Parcel ID: 015-461-07 Structure served by this system Well production at time of test 2.5+ gpm Water storage tank volume NO gallons Well disinfected for coliform test? ❑ Yes ■❑ Nc ■❑ Coliform bacteria is Negative Nitrate 10.1 mg/L ❑ Nitrate less than MRL (ND) Arsenic ug/L ❑■ Arsenic less than MRL (ND) Collected by GEG Date of Sample 7/17/19 LIFT STATION ❑■ Required maintenance completed Age of lift station 16 years Lift station material STEEL Comments: Adequacy test date - Results ❑✓ Pass For 5 bedrooms Fluid depth prior to test in Water added - gal New depth in Elapsed time - min ❑■ Code -required soil cover over field Final fluid depth in ❑ System presoaked Absorption rate gpd (Required if vacant for greater than 30 days prior to Any rejuvenation treatment (past 12 months) date of test) _ If yes, enter date Gallons introduced gallons Comments/Deficiencies: *SEE ATTACHED RECORD DRAWINGS COSA Checklist yellow sheet E. SEPARATION DISTANCES From Private Well on Lot to: (Please enter distances if less than required or if community well) Septic Tank/Lift Station on Lot > 100' 0✓ Yes Community Sewer Manhole/Cleanout > 100' 0✓ Yes if No ft M Yes if No ft Neighboring Tank > 100' 0✓ Yes if No ft Private Sewer/Septic Line > 25' 0✓ Yes if No ft Absorption Field on Lot > 100' 0✓ Yes if No ft Holding Tank > 100' R1 Yes if No ft Neighboring Absorption Fields > 100' Yes if No ft Water Main > 10'✓0 Animal Containment > 50' El Yes if No ft 0✓ Yes if No ft Yes if No ft Water Service Line > 10' Yes if No Manure/Animal Excreta Storage > 100' If septic tank is under driveway Community Sewer Main > 75' 0✓ Yes if No ft 0 Yes if No ft From Septic/Holding Tank on Lot to: (Please enter distances if less than required) Building Foundations > 10' 0✓ Yes if No ft Surface Water > 100' [Z] Yes if No ft Property Line > 5' 0✓ Yes if No ft Wells on Adjacent Lots: 0✓ Absorption Field > 5' ❑✓ Yes if No ft Private Wells > 100' Yes if No ft Water Main > 10'✓0 ft Yes if No ft Community Wells > 200'✓❑ Yes if No ft Water Service Line > 10' Yes if No ft If septic tank is under driveway comment below From Absorption Field on Lot to: (Please enter distances if less than required) Building Foundation > 10' 0✓ Yes if No ft If absorption field is under driveway comment below Property Line > 10' 0✓ Yes if No ft Wells on Adjacent Lots: Water Main > 10' 0 Yes if No ft Private Wells > 100' Q Yes if No Water Service Line > 10' 0✓ Yes if No ft Community Wells > 200' 0✓ Yes if No Surface Water > 100'✓0 Yes if No ft F. ENGINEER'S COMMENTS *CAT III WWTS **SEE ATTACHED PHOTO - TANK APPROXIMATELY 4.5 FEET FROM DECK POST G. ENGINEER'S CERTIFICATION 1 certify that I have determined through field inspections and review of Municipal records that the above systems are in conformance with MOA COSA guidelines in effect on this date. COSA Checklist yellow sheet I J f ey Go ess.- ��4p C r7 53 � f3li.•'• •.c�G pro f essic) r000 #AECC884 ft ft DEVELOPMENT SERVICES DEPARTMENT On -Site water and Wastewater Section www.muni.org/onsite 907-343-7904 r Fax: 343-7997 Nitrate Advisory Certificate of On -Site Systems Approval # OSC191376 Subdivision: Denali View, Block: 3, Lot: 6 A water sample revealed a nitrate concentration of 10.1 milligrams per liter (mg/L). The Environmental Protection Agency (EPA) has established a maximum contaminant level (MCL) of 10.0 mg/L for public drinking water systems. While private wells are not subject to this regulation, EPA standards are based on existing health information and can therefore be used to gauge the relative quality of water from private wells. Please see the attached "Nitrate Fact Sheet" for important information regarding nitrate. This advisory must be attached to all copies of the subject Certificate of On -Site Systems Approval. From Northern Testing Laboratories, Inc. Nitrate is a negatively charged compound of nitrogen and oxygen, which is very soluble in water. Nitrate is not readily filtered or otherwise removed in the soil and can pass rapidly into ground water wells. SOURCE: Nitrate is a major component of fertilizer and wastewater. Often the nitrate is in the form of ammonia or protein first, which through contact with oxygen and certain bacteria, converts to the oxidized form known as nitrate. Sources of nitrate from wastewater include urea, ammonia cleaners, food solids, and bacterial cells. It may also result from the breakdown of organic matter buried in the soil. TOXICITY: Nitrate is generally not toxic to adults or children over the age of two or three years, but is associated with a potentially fatal infant disease called methemoglobinemia. In the digestive system of young children, nitrate converts to nitrite, which can pass through the intestinal wall into the blood stream. There it combines with the hemoglobin and interferes with the ability of the blood to carry oxygen. For this reason, methemoglobinemia is referred to as "blue baby" disease. The EPA limits the concentration of nitrate in public drinking water supplies to 10 mg/L. The standard has been lowered from a previous level of 45 mg/L set by the US Public Health Service and the World Health Organization. TREATMENT: due to its solubility in water and negative ionic charge, filtration and other common home water treatment systems such as softening or iron filtration does not readily remove nitrate. The best method for limiting nitrate in well water is source control. This can include avoiding overdosing of fertilizer near the well and maintaining good separation distances between septic tank leach fields and the well. A special anion exchange filter that contains a media with a strong affinity for negatively charged ions in water, or by a reverse osmosis treatment system or distillation can remove nitrate. TESTING: Nitrate analysis is usually done by one of the several "wet chemical" methods using a spectrophotometer to read the final color endpoint. Specific ion electrodes also can be used to detect the activity of nitrate in water. This laboratory uses several different wet chemical methods approved under the public water supply laboratory certification program. They also have test kits available, which the laboratory uses to perform an inexpensive "screening test", and with which the homeowner can monitor the change in nitrate levels from their well. They recommend comparing the test kit results against a certified analysis from the lab occasionally to verify the accuracy of the kit. We recommend using a specially prepared bottle that has been rinsed in hydrochloric acid for collecting samples. ox5Q'AeEAi95� 6 Q *intirtr�i�i�g :�"S'�' 9�a���E��,.,"��a IV HOME SERVICES INC. 7501 E. 140th Avenue Anchorage, Alaska 99516 345-1890 -CUSTOM ER Poo WL ..-Block Lot DATE DESCRIPT16N, 0 66 Tan!.: W Gallons Septic Leach Area Holding Tank Standpipes Time El PROBLEM AREA CALL FOR MORE INFORMATION El NEEDS 70 BE DONE AGAIN IN 6 MONTHS El Good Shape ❑ sludge buildup on bottom ❑ Floater on top Jim cap missing or ET Cut standpipe to 1' above ground El Needs Septictrine needs replacing Sonja Blewett From: Jeff Garness Sent: Saturday, August 17, 2019 11:52 AM To: Sonja Blewett Subject: FW: 12300 Sultana From: David Harper<dlharper2@gmail.com> Sent: Saturday, August 17, 2019 8:07 AM To: Jeff Garness <Jeff@garnessengineering.com> Subject: 12300 Sultana Jeff, as in the previous report from checking the well interior with a camera, there was a small amount of water from a fracture at 41.5 feet below grade. A PVC liner was installed with a shale packer to 52 feet below grade and bentonite chips were positioned above the packer which when hydrated forms a seal so the incoming water cannot go down the well. it overlaps the fracture so the water cannot go up the well bore also. As this water has been entering the well for some time , I assume it will be a continuing lowering of nitrate count as water is used. David Harper Aarow Pump & Well Service, LLC MUNICIPALITY OF ANCHORAGE ADVANCED WASTEWATER TREATMENT SYSTEM MAINTENANCE AND REPAIR AGREEMENT THIS MAINTENANCE AND REPAIR AGREEMENT, herein the "AGREEMENT" made and entered into as of thinrs__ 30'A Day of of 20j_q _, by and between V -S �e l�'� , herein the "OWNER," and the Municipality of Anchorage, herein the "MUNICIPALITY", in accordance with Anchorage Municipal Code (AMC) 15.65.365. In consideration of the mutual covenants contained herein, the parties to this Agreement agree as follows: 1. Advanced Wastewater Treatment Systems. The Municipality grants permission to the Owner to utilize and operate an Advanced Wastewater Treatment System (AWWTS), described as ( _IDSF -- - -- - - - located at (legal description) Denali View 133 L6 - - --- 2. Maintenance, Repairs and Alterations. (Owner is required to read, understand and initial each section) (= Throughout the term of this Agreement, the Owner shall enter into a service agreement with an AWWTS service and maintenance provider approved by the Municipality or the manufacturer's representative. The AWWTS shall be maintained in a satisfactory condition capable of performing as designed and producing treated septic effluent in accordance with the equipment's approval for operation in the Municipality. It shall be the responsibility of the Owner during the term of this Agreement to pay for all repair(s), maintenance, adjustment(s), replacement costs, and inspection costs. This includes an annual maintenance fee (typically $400 to $600). Owner agrees that only maintenance and repair personnel approved by the Municipality or the manufacturer's representative will inspect and make any necessary maintenance, repairs or permitted alterations to the system. Owner acknowledges that regular maintenance of an AWWTS reduces the potential failure of the system, which could include sewage backup and costly repairs or drainfield replacement. (rev. 05/18/2018) Page 1 of 3 Owner acknowledges that the Municipality may request records of maintenance and repairs from the manufacturer's representative or maintenance provider. Owner acknowledges that the fine for failing to maintain and repair an AWWTS may be assessed in accordance with AMC 14.60.030. Owner agrees to grant the Municipality reasonable access to test and inspect the AWWTS. The Municipality will give at least 24-hour notice. r l� Owner agrees that any sale or transfer of title of the property will not occur without a new Certificate of On -Site Systems Approval. Tk Owner agrees that the AWWTS installation and maintenance requirements as provided by the AWWTS vendor/installer and approved by the Municipality are the governing y guidelines for the construction, maintenance and repair of the Owner's AWWTS. 1 r Owner agrees to. maintain remote monitoring of the AWWTS as required by the AWWTS approval. 3. Term. The term of this Agreement shall begin on the date of approval by the Municipality to operate the installed system, or upon transfer of title, and shall continue while the AWWTS is operational or until title is transferred. 4. Nonwaiver. The failure of the Municipality at any time to enforce a provision of this Agreement shall in no way constitute a waiver of the provisions, nor in any way affect the validity of the Agreement or any part hereof, or the right of the Municipality thereafter to enforce every provision hereof. 5. Amendment. This Agreement shall only be amended by authorized representatives of the Owner and Municipality. Any attempt to amend this agreement by either an unauthorized representative or unauthorized means shall be void. 6. Jurisdiction: Choice of Law. Any civil action arising from this Agreement shall be brought in the Superior Court for the Third Judicial District of the State of Alaska at Anchorage. The laws of the State of Alaska shall govern the rights and obligations of the parties under this Agreement. 7. Severability. Any provisions of this Agreement decreed invalid by a court of competent jurisdiction shall not invalidate the remaining provisions of the Agreement. (rev. 05/18/2018) Page 2 of 3 OWNER: , By: (signature) Date: 7137-,qj9 (Print name) STATE OF ALASKA ) ) ss. THIRD JUDICIAL DISTRICT ) The foregoing instrument was acknowledged before me this -96 day of 30 l , 20 0L, by -rhm.t, 94W tAE iW ., NZMURY PUBLIC FOR ALASKA My Commission expires: 0 3 MUNICIPALITY: _ J By: (ti� G (signature) name) Date: l Title: (rev. 05/18/2018) Page 3 of 3 Jeff Garness From: David Harper <dlharper2@gmail.com> Sent: Thursday, July 18, 2019 11:39 AM To: Jeff Garness Subject: 12300 Sultana Ct There were no fractures or incoming water encountered during the camera viewing of the well located at the above address to a depth of 40 feet ground level. However there was incoming water of approximately a 32cnd of a gallon per minute coming through a fracture 41 to 41.5 feet ground level. David Harper Aarow Pump & Well Service, LLC Sent from my iPhone PLAT NO. 76-211 DENALI VIEW SUBDIVISION LOT 6, BLOCK 3 42.115 S.F. -rnNA ORNE ®��P�.OF1�A�gs�♦ a x'•49 !V k®® r ...00 • : Jeffery A. Gasm7Ci •� ®? LS -6091 • m m a '• _ 8/0!2019 �p afp55ianal lana S sof�sle�e®® Ex/ll AS -BU I L T I HEREBY CERTIFY THAT I HAVE SURVEYED THE GASTALDI LAND PROPERTY DEPICTED ABOVE AND THAT NO ENCROACHMENTS EXIST EXCEPT AS INDICATED. SURVEYING. LLC 1T IS THE RESPONSIBIUIY OF THE OWNER TO JEFF A GASTALDI. R.L.S. DETERMINE THE EXISTENCE OF ANY EASEMENTS. 2000 1— DOWLING RD.. SUITE 8 COVENANTS OR RESTRICTIONS WHICH DO NOT ANCHORAGE. ALASKA 99507 APPS ON THE RECORDED SUBDIVISION PLAT. PHONE 248-5454 UNDER NO CIRCUMSTANCES SHOULD ANY DATA GRID DATE HEREON BE USED FOR CONSTRUCTION OR FOR SW2741 8/8/2019 ESTABLISHING BOUNDARY OR FENCE LINES. ANCHORAGE RECORDING DISTRICT. ALASKA F.B. Joe N0. 00-13 0V563 NOTE: NO CORNERS SET THIS DATE Municipality of Anchorage Development Services Department Building Safety Division On-Site Water & Wastewater Program 4700 South Bragaw SL P.O. Box 196650 Anchorage, AK 99519-6650 www.ci.anchorag e.ak.us (907) 343-7904 CERTIFICATE OF HEALTH AUTHORITY APPROVAL FOR A SINGLE FAHILY DWELLING Parcel I.D. 015-461-07 · 1. GENERAL INFORMATION Expiration Date: 7 '-~' "2., .~ 0 ~ Complete legal description DENALI V1EW SUBDIVISION; LOT 6, BLOCK 3,'. '; Location (site address or directions) 12300 SULTANA COURT * ANCHORAGE, AK 99516 Current Property owner(s) Mailing address Lending agency Mailing address Real Estate Agent Mailing address WESLEY & BARBARA CLUBB Dayphone 346-2329 12300 SULTANA COURT * ANCHORAGE~ AK 99516 Day phone JEANNE BIERLEiN w/ DYNAMIC PROPERTIES Day phone 244-1921 ,3111 "C" STREET SUITE 200 '~ ANCHORAGE, AK 99503 Unless otherwise requested, HAA wi//be he/d by DSD for pickup. 2. NUMBER OF BEDROOMS: 5 3. TYPE OFWATER SUPPLY: Individual Well ~r~ Individual Water Storage Community Class Well [~ Public Water System II TYPE OF WASTEWATER DISPOSAL: Individual On-site Individual Holding tank Community On-site Public Sewer The Municipality of Anchorage Development Services Department (DSD) Issues Certificates of Health Authority Approval (HAA) based only upon the representations given in paragraph 4 by an independent professional civil engineer registered in the State of Alaska. Certificates of Health Authority Approval are required for the transfer of title (except between spouses) for properties served by a single-family on-site wastewater disposal and/or water supply system. DSD also issues HAAs upon request to homeowners. Cedificates of Health Authority Approval are valid for 90 days from the date of issue for properties served by a private or Class C well and may be reissued with new water samples. (Certificates may be reissued for a period of up to one year with valid water samples.) Certificates are valid for one year for properties served by Class A or B wells or a public water system. The Municipality of Anchorage is not responsible for errors or omissions in the professional engineer'~ work. Note: Alaska Water and Wastewater Consultants, Inc. shall be paid $ at, or pdor to closing for the engineering services provided. 4. STATEMENT OF INSPECTION BY ENGINEER · As certified by my seal affixed hereto and as of the validation date shown below, I ve6fy that my investigation, based on procedures outlined in the Health Authorfty Approval Guidelines for this application, shows that the on-site water supply and/or wastewater disposal system is(are) safe, functional and adequate for the number of bedrooms and type of structure indicated herein. I further vedfy that based on the information obtained from the Municipality of Anchorage files and from my investigation and inspection, the on-site water supply and/or wastewater disposal system is(are) in compliance with all applicable Municipal and State codes, ordinances, and regulations In effect at the time of installation. NameofFirm ALASKA WATER &: WASTEWATER CONSULTANTS, INC. Phone 337-6179 Address 6901 DEBARR ROAD, SUITE: 2B * ANCHORAGE, AK 99504 Engineer*s Printed Name JEFFREY A. C, ARNESS, P.E. Engineers Comments: In conducting this evaluation, AWWC, Inc. attempted to provide a thorough, conscientious enginee6ng analysis of the system in accordance with ADEC and MOA DSD Guidelines & Regulations. The reported results described the performance of the system under the conditions encountered at the time of the test, and separation distances measured to readily identifiable features. The operational life of all wells and septic systems depend on the local soils condition, groundwater levels that may fluctuate during the year, and the water usage of the family being served by the system. These conditions are outside the control of the evaluator of the system. Satisfectory test results do not guarantee future perfo~Tnance of the system, nor do they guarantee that there are no hidden defects or encroachments. A WWC, Inc. can therefore not provide any warranty or future estimate of how long the system will continue to meet the operational requirements of the ADEC or MOA DSD. The content of this report is for the sole benefit of the owner listed above. Any reliance upon or use of this report by any olher person or party is not authorized, nor will it confer any legal right whatsoever. 5. DSD SIGNATURE Approved for bedrooms. Disapproved. Z Conditional approval for .5 bedrooms, with the fllowing stipulations: At the time of title transfer the new ow=er shall sign the attached maintenance agreement which shall be returned to this office before a unconditional approval is issued. Attachments: HAA Checklist Septic System Advisory Well Flow Advisory X Manitenance Agreements Supplemental Engineer's Reort Other X Original Certificate Date: Z./- '~-~ ~__ Legal Description: A. WELL DATA Municipality of Anchorage Development Services Department Building Safety Division On-Site Wafer & Wasfewatar Program 4700 South Bmgaw St. P.O. Box 196650 Anchorage, AX 99519-6650 www.ct.ancherage.ak.u~ (~07) ~,.~-~'~04 HEALTH AUTHORITY APPROVAL CHECKLIST DENAU ViEW SUBDNISION; LOT 6~ BLOCK 3 Parcel ID: 015-461-07 Well type PRNATE If A, B, or C provide PWSID~ N/A Date completed 4`/6`/2000 Sanitary seal (Y/N) YES Total depth 226 ft. Cased to 20 ft. FROM WELL LOG Date of test 4`//6`/2000 Static water level 13 ff. Well production 4 WATER SAMPLE RESULTS: Colifo~n 0 colonies/100 mi. Arsenic: 1.9 mg./L. SEPTIC/HOLDING TANK DATA Tank Type/Matertal g.p.m. Well Log (Y/N) YES Wires properly protected (Y/N) Casing height (above ground) 24+ AT INSPECTION Tank size 2000 gal. Foundation cieanout (Y/N) YES Date of pumping 3`/25`/2002 ABSORPTION FIELD DATA Date installed 4/29/2000 Length 30 ft. g.p.m. in. Nitrate 1.97 mg./L. Other bacteria 0 colonies/100 mi. Date of sample: 2`//8`/2002 Collected by: AWWC~ INC. STEEL Number of Compartments 2 Depression over tank (Y/N) NO Pumper * LESS THAN 2 YEARS OLD Soil rating ~r ft~edrm) 3.0 Width 12 .ft. Date installed 4/28`/2000 Cteanoufe (Y/N). YES High water alarm (Y/N) YES A+ HOME SERVICES Total depth --8,8 ff. Eft, absorption area 360 fi2 Monitoring tuba***YEs Date of adequacy test *NEW Results (PessJFall). - Fluid depth in absorption field before test - in. Water added - gal. Elapsed Time: - min. Final fluid depth - in. Absorption rate >= Any rejuvenation treatment (past 12 mo.) (Y/N & type) N/A If yes. give date ** TO TOP OF SAND PER 11/6/00 INSPECTION REPORT ~** SYSTEM DRY 3/5/02 System type ~ro~e.~ss Gravel below pipe .5 ft. Depression over field NO For ,5 bedrooms New depth - in. - g.p,d. LIFT STATION Date installed Size in gallons ~ 'Pump on" level at. in. 'Pump n. High water alarm level at .in. Datum Cycles tested Meets alarm & circuit requirements? E. SEPARATION DISTANCES Septic tank/lift station on lot Absorption field on lot Public sewer main Sewer/septic service line SEPARATION DISTANCES FROM WELL ON LOT TO: 100'+ 100'+ N/^ 25'+ SEPARATION DISTANCES FROM SEPTIC/HOLDING TANK ON LOT TO: Building foundation 5'+ Property line Water main N/A Water service line 10'4- Wells on adjacent lots 100'+ SEPARATION DISTANCE FROM ABSORPTION FIELD ON LOT TO: Property line 10'+ Water service line 10'+ Curtain drain NONE KNOWN F. COMMENTS G. ENGINEER'S CERTIFICATION Building foundation 10'+ Surface water 100'+ Wells on adjacent lots 100'+ On adjacent lots 100'+ On adjacent lots 100'+ Public sewer manhole/cieanout Holding tank N/A Absorption field 5'+ Surface water 100'+ I certify that I have determined through field inspections and review of Municipal records that the above systems are in conformance with MOA HAA guidelines in effect on this date. Water main N/A Driveway, parking/vehicle storage 25'+ Engineer's Printed Hame Date dEFFREY A. GARNESS HAA Fee $. Date of Payment Receipt Number (Rev. 12/01) Waiver Fee $ Date of Payment Receipt Number FEB-18-02 04:40P" FR01~CI'&£ EN¥1"0NgENTAL ''~tK CT&E Environmental Services inc. 9075615301 T-435 P.0Z/03 F-934 CT&E Ref.~ Client Name Project Namc/~ Client Sample ID Matrix Ordered By PWSlD Sample Remarks: 1020779001 AK. Water & Wastewater Consultants Inc. Lot 6, Block 3 Denali View S/D Lot 6, Block 3 Denali View S/D Drinking Water Client PO# Printed Date4Time 02/18/2002 14:07 Collecled Date/Time 02108/2002 12:50 Received Date/Time 02/08/2002 14:54 Technical Director Stephen C. £de Released By ~ Private Individual 3Lnalynla Aluminum A~scnic Barium Cadmium Calcium Chromium Copper Iron Lead Magnesium Manganese Phosphorus Potassium Sadmm Silicon Silver Zinc Onlonde Fluoride Nitrate-N Nitrite-N Sulfate Total Dissolved Solids HCO3 Alkalinity CO3 Alkalinity OH Alkalinity Conducfivhy pR Alkahnity Total Coliform PQL Units Mc~hod Allowable Prep Anal/sis Limits Date Date Init 20.0 U 20.0 ng/L EPA 200.8 (<50) 02/18/02 KGF 1.90 1.50 ug/L EPA 200.8 (<~0) 02/18/02 KOF 55.4 3.00 ug/L EPA 200.8 (<2000) 02/I 8/02 KGF O.10OU 0.100 ug/L EPA 2008 f<51 02/18/02 KGF 56]00 500 ug/L EPA 200.8 02/18/02 KGF 3.00 U 3.00 og/L £PA 200.8 (<100) 02/18/02 KGF 55.9 0.800 ug/L EPA 200.8 (<1300) 02/18/02 KGF 250 U 250 ug/L EPA 200.8 (<300) 02/18/02 KGF 0.727 0.400 ug/L EPA 200.8 (<l 5 ) 02/18/02 KGF 12200 $00 ug/L EPA 200.8 02/18/02 KGF 3.00 U 3.00 ng/L EPA 200.8 (<501 02/18/02 KOF 500 U 500 ug/L EPA 200.8 02/18/02 KGI; 500 U $00 ug/L EPA 200.8 02/1~02 KGF 4590 500 ug/t. EPA 200.8 02/18/02 KGE 5380 lO00 ug/L EPA 200.8 02/I g/02 KQF 1.00U 1.00 ug/L EPA 200.8 (<100) 02/18/02 KO[ 12.7 2.00 ug/L EPA 200.8 (<5000) 02/18/02 KG! 8.76 0.200 mg/L EPA 300.0 (<2501 02/08/02 JD'I 0.200 U 0.200 mg/L EPA 300.0 (<2) 02/08/02 1.97 0.200 mg/L EPA 300.0 (<10} 02/08/02 JD' 0.200 U 0.200 mg/L EPA 300.0 (<1) 02/08/02 JD' 15.6 0.200 mgdL EPA 300.0 (<2501 02/08/O2 274 80.0 mg/L SM20 2540C (<500) 02/08/02 SD] 167 mg/L SM20 2320Pt 02/13/02 0.00 mg/L SM20 2320/3 02/13/02 SBI 0.00 mg/L SM20 2320D 02/13/02 SB~ 420 2.00 umho~/cm SM2510rl 02/08/02 7.36 0.100 pi[units EPA 150.1 (6.5-8.$) 02/08/02 SPt 167 ! 0.0 mg/L SM20 232013 02/I 3/02 0 eol/100mL SMI8 922213 (<11 02/08/02 ICa C F~ : GASTPi. D I Lf~qD ~ : 9072489~62 Rpr. ~ 21~2 ~4:5-JA~ P1 Municipality of Anchorage Department of Health and Human Services Division of Environmental Services On-Site Services Section 825 "L" Street Room 502 P.O. Box 196650 Anchorage, AK 99519-6650 www. ci.anchorage.ak.us (907) 343-4744 CERTIFICATE OF HEALTH AUTHORITY APPROVAL FOR A SINGLE FAMILY DWELLING Parcel I.D. 01 5-461-07 1. GENERAL INFORMATION Complete legal description Expiration Date: Lot 6, Block 3, Denali View Subdivision Location (site address or directions) Current Property owner(s) Mailing address Crown Pointe, Inc. Dayphone 345-6277 P.O. Box 112313 Anchorage, AK 99511 Lending agency Mailing address Day phone Real Estate Agent Mailing Address Day phone Unless otherwise requested, HAA will be held by DHHS for pickup. HAA picked up by: NUMBER OF BEDROOMS: TYPE OF WATER SUPPLY: Individual Well Individual Water Storage Community Class Public Water System Five (5) Well TYPE OF WASTEWATER DISPOSAL: [] Individual On-site [] [] Individual Holding Tank [] [] Community On-site [] [] Public Sewer [] The Municipality of Anchorage Department of Health and Human Services (DHHS) issues Certificates cf Health Authority Approval (HAA) based only upon the representations given in paragraph 5 by an independem professional civil engineer registered in the State of Alaska. Certificates of Health Authority Approval are required for the transfer of title (except between spouses) on properties served by a single family on-site wastewater disposal and/or water supply system. DHHS also issues HAAs upon request to home owners. Certificates of Health Authority Approval are valid for 90 days from the date of issue for properties served by a private or Class C well and may be reissued with new water sample results less than 30 days old. Certificate~ are vatid for one year for properties served by Class A or B wells or a public water system. The Municipalir., of Anchorage is not responsible for errors or omissions in the professional engineer's work. 72-035 ~Rev O! 00)' 5. ' STATEMENT OF INSPECTION BY ENGINEER As certified by my seal affixed hereto and as oi the validation date sh~)wn below, I verify that my investigation based on procedures outlined in the Health Authority Approval Guidelines for the Health Authority Approval application show that the on-site water supply and/or wastewater disposal system is safe, functional and adequate for the number of bedrooms and type of structure indicated herein. I further verify that based on the information obtained from the Municipality of Anchorage files and from my investigation and inspection, the on- site water supply and/or wastewater disposal system is in compliance with all applicable Municipal and State codes, ordinances, and regulations in effect at the time of installation. Name of Firm Anders6n Engineering ' ' ' Phone '522-7773 Address P.O. Box 240773 Anchorage, AK 99524 Engineer's Printed Name Michael E. Anderson, P.E. Date 11/29/00 DHHS SIGNATURE Approved for bedrooms. Disapproved. , - .~. .~ Conditional approval for bedrooms, with the following stipu~i~ns. Additional Comments Attachments: HAA Checklist Septic System Advisory Well Flow Advisory Maintenance Agreements Supplemental Engineer's Report Other Expiration Date: ~ - ~" - 0 ~ Original Certificate Date: Reissue Date: 12 75-025 (Rev 01,'00i' Legal Description: Lot 6 A. WELL DATA Well type Date completed 4 / 6 / 0 0 Total depth _2Z6__ ft ' Municipality of Anchorage R E C E I V E Department of Health and Human Services Division of Environmental Sewices On-Site Services Section 825 "L' Street Room 502 NOV ~. 9 2000 P.O. Box 196650 Anchorage, AK 99519-6650 www.ci.anchorage, ak.us MUNICIPALITY OF ANCHORAGE (907) 343-4744 ENVIRONMENTAL SERVICES OltqSION HEALTH AUTHORITY APPROVAL CHECKLIST Block 3~ Denalt View Subdivision If A, B, or C provide PWSID # Sanitary seal ¥ Cased to ? N ft FROM WELL LOG Date of test 4 / 6 / 00 Static water level 1 3 ft Well production 4 g.p.m WATER SAMPLE RESULTS: Coliform 0 colonies/100 mi Nitrate 3.1 1 mg/I Date of sample: 1 1 / 2 7 / 0 0 Collected by: B. SEPTIC/HOLDING TANK DATA Tank Typs/Material Septic STEP/Steel Data installed 4/28/00 Tanksize 2,000 gal Cleanouts ¥ Foundation cleanout Y Depression over tank Date of pumping [qew Construction Pumper N/A C. ABSORPTION RELD DATA Date installed 4/29/00 Soil rating (g.p.d./tt2 or ft2/bdrm) 3 Length 30 fl Width 12 ft Gravel below pipe .5 Totaldepth 11 ff Effective absorption area 360fl Date of adequacy test New ¢onst .Results (Pass/Fail) Fluid depth in absorption field before test __ in Water added__ Elapsed Time: min Final fluid depth in Any rejuvenation treatment (past 12 mo.) (Y/N & type) N Parcel I.D.: 015-461-07 Well Log ¥ Wires properly protected ¥ Casing height (above ground) 2 4 AT INSPECTION ft g.p.m Other bacteria 0 colonies/100 mi Number of Compartments 3 High water alarm __ in. System type Bottomless Sand Filter __ Depression over field N For bedrooms gal. New depth in. Absorption rate >= g.p.d. If yes, give date H/A 72-02~ (l:~v. 01~)· D. LIFT STATION Date installed 4/28/00 "Pump on" level at 42 in Datum R~'l'~m C~:~ m,~nk Size in gallons 500 Manhole/Access y "Pump off" level at 42 in High water alarm level at 44 in Cycles tested New Const. Meets alarm & cimuit requirements Y SEPARATION DISTANCES SEPARATION DISTANCES FROM WELL ON LOT TO: Septic tank/lilt station on lot > 100 ' On adjacent lots > 100' On adjacent lots > 100 ' Public sewer manhole/cleanout N/A Holding tank N/A Absorption field on lot Public sewer main Sewer/septic service line Property line > 10 ' Water Service line > 10 ' Curtain drain None Noted F. COMMENTS Building foundation > 10' Surface water > 100 ' Wells on adjacent lots > 100 ' >100' SEPARATION DISTANCES FROM SEPTIC/HOLDING TANK ON LOT TO: Building foundation > 5 ' Property line > 5 ' Absorption field > 5 ' Water main N/A Water service line > 10 ' Surface water > 1 00 ' Drainage > 1 00 ' Wells on adjacent lots > 100 ' SEPARATION DISTANCE FROM ABSORPTION FIELD ON LOTTO: Water main N/A Driveway, parking/vehicle storage > 20' _7'. ~ill Place__~.~d Ove__r Tan___~k and Field___._I. G. ENGINEER'S CERTIFICATION Ice. rtify that I have determined through field inspections uno revmw of Muni~pel records that the above systems are in conformance w,th MOA HAA guidelines in e.ect on this date. Engineer's Printed Name Michael E. Anderson, P. Date 11/29/00 Receipt Number / Waiver Fee $ Date of Payment Receipt Number 72-03~ (Re~. 01~o}'