ON-SITE WASTEWATER DISPOSAL SYSTEM AND/OR WELL INSPECTION REPORT
Permit Number: SW010196 PID Number: 017-37333-07
Richard Gelardin WastewaterSystem: New ~;~ Upgrade
3333040 Shelburne Road~ Anch. AK 9953336 ABSORPTION FIELD
Three (3) Deep Trench
LEGAL DESCRIPTION .8 o,~e 3331
I 21 r Knik Heights 3 F,. 8
1 n. 40 ~,.
Well: Existing 3 n. !I N/A
n. n. 640 .' ASTM D3034 PVC
n. Acreal~e Systems 6/26/01
'"'": o~ I n'~'s":., ic~, ~.,~c.,,.~:. TANK
SEPARATION DISTANCES E3 Septic n Holding n S.T.E.P. f-I Other.
SepUc Absorption Lift Holding ,ublicJPrlvate
Tank Field Station Tank Se,~U,,e ' Anchorage Tank 1,000
w~ >33300' >33300' N/A N/A >25' Steel Two (2)
~..~w... >33300'>33300' N/A N/A ~ / LIFT STATION - NONE ON LOT
V
~, >5' >3.0' N/A N/A
~__>5,>ZO, N/AN/A/~"~'p*'--.':"~'.~'"'.': I'~''''-''.
c~,.~ None Noted ~o~..,~,~
"'~'~: BENCH MARK
Existing Septic Tank Pumped and Removed From
Site. Existing Absorption System Connected to New Top of Foundation Cleanout.
System with Bull Run Flow Diverter Valve. 100.0
Engineer's Stamp
Inspections performed by: Mike Anderson Dates: 1" 6/26/0333 . ~ mh ~
6/26/0333
Department of44ealth aod I:luman Services approval
Reviewed and approved by: Date: $;.~'-~;~'.~
Municipality of Anchorage
DEVELOPMENT SERVICES DEPARTMENT
4700 South Bragaw Street Anchorage, AK 99519-6650 - 343-7904
On-Site Wastewater Disposal System or Well Inspection Report
Permit Number SW010196
PID No. 017-371-07
Page 2 of 3
C4
~Three
]louse
A B
S1 22.2 63.6
S2 28.4 69.2
C4 57.8 97.1
M1 49.9 84.7
DY 32.8 72.O
C5 46.3 72.5
E~ist
LEGEND
~V - Septic Vent
Bull Run Diverter Valve
C - Cleanout
M - Monitor Tube
PLAN AS-BUILT
SCALE 1" = 30'
Municipality of Anchorage
DEVELOPMENT SERVICES DEPARTMENT
4700 South 8ragaw Street Anchorage, AK 99519-6650 - 343-7904
On-Site Wastewater Disposal System or Well Inspection Report
Permit Number SW010196
PID No. 017-371-07
Page 3 of 3
87.3
90.5
Geotextile
Drainfield
Fabric
Rock
~79.3
87.3
MUNICIPAUTY OF ANCHORAGE
Development Services Department
On-Site Water & Wastewater Program
4700 South Bragaw Street
P.O. Box 196650, Anchorage, AK 90519-6650
(907) 343-7904
ON-SITE WASTEWATER DISPOSAL SYSTEM PERMIT
Upgrade
Date Issued: Jun 18, 2001
Expiration Date: Jun 18, 2002
Permit Number: SW010196
'.Legal Description: KNIK HEIGHTS BLK I LT 21
Design Engineer: 0014 Anderson Engineering
Owner Name: GELARDIN RICHARD
Owner Address: 13040 SHELBURNE ROAD
ANCHORAGE, AK 99516-2925
Parcel ID: 017-371-07
Site Address: 013040 SHELBURNE RD
Lot Size: 24800 SQ. FT.
Total Bedrooms: 3 Permit Bedrooms: 3
This permit is for the construction of:
[] Disposal Field [] Septic Tank [] Holding Tank [] Privy
[] Private Well [] Water Storage
Ail construction must be in accordance with:
1. The attached approved design.
2. All requirements specified in Anchorage Municipal Code Chapters 15.55 an~ 15.65 and the State of Alaska
Wastewater Disposal Regulations ( 18AAC72 ) and Drinking Water Regulations ( 18AAC80 ).
3. The engineer must notify DSD at least 2 hours prior to each inspection. Provide notification by calling
(907) 343-7904 ( 24 hours ). ( Not required for a Water Supply Permit only ).
4. From October 15 to April 15, a subsurface soil absorption system under construction during freezing weather
must be either: A. Open and closed on the same day.
B. Covered, sealed, and heated to prevent freezing.
Received By: Date:
Issued By: Date: ~ '~ /
Municipality of Anchorage
Development Services Department
Building Safety Division
On-Site Water and Wastewater Program
4700 South Bragaw St.
P.O. Box 196650 Anchorage, AK 99519-6650
www.ci.anchorage.ak.us
(907) 343-7904
ON-SITE SEWEPJWELL PERMIT APPLICATION
FOR A SINGLE FAMILY DWELLING
Parcel I.D. 017.371-07
Permit Number~
Property owner(s) Richard Gelardin
Mailing address (1) '13040 Shelbume Road Anchorage~ AK 99511-2848
~-~g address (2) /~D ~/c~ ~ J,.cl [-,~,/-/t~_ '~-~. Zip Code
Legal description (Lot, Block & Sub'd.) Lot 2t~ Block I, Knlk Hel.qhts Subdivision
Legal description (Section, Township & Range)
__,~,, ~'~1:::) Acres/Sq. Ft. Number of Bedrooms Three {3)
Lot
Size
Day phone 345-7787
· THIS APPLICATION IS FOR:
Sewer Only
Sewer and Well
Sewer Upgrade
THIS PROPERTY CONTAINS:
Hot Tub
Swimming Pool
Therapy Pool
~;~ Well Only []
[] Water Storage []
Jacuzzi
Water Softening Unit
I certify that the above information is correct. I further certify that this application is being made for a
Single Family Dwelling and is in accordance with applicable Municipal Codes.
(Signature of property owner or authorized agent)
Permit Fees:
Date of Payment:
Receipt Number:
(Rev. 12/00)
Waiver Fees:
Date of Payment:
Receipt Number:
ANDERSON ENGINEERING
P.O. BOX~ 240773
ANCHORAGE, AK 99524 r
522-7773 522-6779 (FAX)
June 5, 2001
Municipality of Anchorage
Development Services Department
On-Site Water and Wastewater Program
4700 South Bragaw Street
Anchorage, AK 99519-6650
Subject:
Lot 21, Block I, Knik Heights Subdivision
Septic System Design and Permit Application
Impacts to Adjacent Properties
Dear Onsite Services Engineer:.
The absorption trench on Lot 21, Block I, Knik Heights Subdivision has failed and
effluent is currently pooling on the ground surface. We are therefore applying for a
permit to construct a new septic system on the lot to serve the throe bedroom home.
The attached Site Plan and backup documentation identify the location and
configuration of the new septic system and the parameters used in the design. Also
identified on the plans ara the location of the existing well along with the test hole and
the existing absorption site. Existing dralnage patterns are shown and will not be
altered by the development of the lot. We have surveyed the area and the new system
will not conflict with other wells or septic systems in the area.
A test hole was recently placed on the lot.to determine subsurface conditions. Soils
were found to be well graded gravel with varying amounts of silt. A percolation test in
the material indicated rates approximating 6 to 8 minutes per inch. No groundwater
was found during the excavation and none was found during the monitoring period. We
are therefore proposing to place an absorption trench 36' long by 3' wide with a 8'
effective depth to treat the septic effluent. The distribution pipe will be placed at 2'
below the surface for a total depth of 10'. A Zabel Flow Diverter Valve will be installed
and the existing absorption trench tied in for future use. The existing fiberglass septic
tank will be abandoned in accordance with ADEC and Municipal requirements.
The ground surface on the lot slopes as shown on the attached Site Plan with grades
from east to west and flatten in the area of the test hole. The new absorption trench will
be constructed parallel to the contours of the surface as much as possible in
conformance with Municipal requirements. Grading will be accomplished to assure
surface drainage is aw. ay from the new trench. The existing drainage pattern on the lot
will not be affected dunng development.
If the system is constructed in accordance with our design the following statements
apply:
The system, if constructed as designed, will have no adverse impact on the wells
Lot 21, Block I, Knlk Heights
June 5, 2001
Page Two
in the area or those to be constructed in the future.
The system, if constructed as designed, will have no adverse impact on existing
septic systems in the area or those to be constructed in the future.
The system, if constructed as designed, will have no adverse impact on reserve
space, either surface or subsurface, on any lots located in the area.
The system, if constructed as designed, will have no adverse impact on drainage
patterns in the area. The current drainage pattern will be maintained.
Sincerely,
Michael E. Anderson, P.E.
Attachments
I
22 ·
IECT
'1
· I!
I
I
I
7
8
AREA MAP-
SCALE 1" ~= 100'
SCOPE OF WORK:
1. Verify Foundation Cleanout
2. Remove and Dispose Existing Septic Tank.
'3. Place New 1,000 Gallon Septlc Tank. 4. Place 2 Post Tank Cleanouts.
5. Place Zabel Flow DiverterValve and Tie in
Existing AbsorpUon Trench.
~. Construct New 36' Long X 3' Wide X 8' Effective
Depth Absorption Trench.
7. Regrade All Disturbed Areas.
8. Revegetate Area As Required.
i
Zabel Flow
Diverter Valve
New Gallon
Tank
Three
~ ~ House
'~ · .
SITE PLAN
SCALE1"=30'
LOT 12, BLOCK I, KNIK HEIGHTS SUBDIVISION
DESIGN FACTORS:
SYSTEM REQUIREMENTS:
Three Bedroom Home Deep Trench System
Perc. Rate: 6-8 MinJInch 1,000 Gallon Septic Tank
Application Rate: .8 GPD/SF 8' Drain Field Rock
3 Bedrooms X 150 GPD 1.8 GPD/SF = 562.5 SF of Absorption Area
562.5 SFI16SFA.F = 35~ LF Trench Length
Therefore: Construct an Absorption Trench 36' in Length by 3' Wide W'dh 8' of Dralnfleld
Rock Beneath the Distribution Lateral. Distribution Lateral to Be Placed 2' Below Existing
Ground. Total Depth of Trench to Be 10' f~om Existing Surface. Mound Over Trench if
Necessa~j to Provide Minimum Cover of 3'.
NOTE:
TYPICAL DEEP TRENCH SECTION
(NO SCALE)
Grade Area Over Trench to Drain Away.
Minimum 6' Separation From Bedrock.
Minimum 10' Separation From Lot Une.
Minimum 4' Separation From Groundwater.
Minimum 100' Separation From Wells in the Area.
Maintain 50' Separation From Slope >25%.
Municipality of Anchorage
Department of Health & Human Services
825 L Street, Anchorage, AK 99502-0650
SOILS LOG - PERCOLATION TEST
Performed For: Richard Gelardin
Legal Description: Lot 21. Block I. Knik Heights Subdivision
SLOPE
North
OGIOI..
GW
Some Silt
5
6
South
Was Groundwater
Encountered? No
If Yes, What Depth?
1 Depth to Water
After Monitoring None P
11 Date: 6/5101 E
14
15
Bottom of
Hole
17
18
SITE PLAN
See Site Plan
5%
1 5%-20%
Reading Date Gross Net Depth To Net
Time Time Water Drop
16-May 12:41 2.25"
1:11 30 6.75' 4.5'
1:12 2,125"
1:42 30 6.5' 4.375"
1:43 2"
2:13 30 6.375" 4.375"
21
Pert. Rate: 6.8 Min./inch Perc. Hole Diameter: 6'
Test Run Between 4 Ft. and 5 Ft.
Comments: Test Cavity was Presoaked Prior to Test.
Pedormed By: Mike Anderson. I, Michael E_ Andersen Certify That This Test Was Performed
In Accordance With All State and Municipal Guidelines In Effect On This Date: 6/4/01
ON-SITE WASTEWATER DISPOSAL SYSTEM
CONSTRUCTION AND MATERIAL SPECIFICATIONS
SUBJECT: LOT 21, BLOCK I, KNIK HEIGHTS SUBDIVISION
GENERAL:
o
The scope of this project includes the abandonment of the existing
1,000-gallon fiberglass septic tank and the procurement and
placement of a new 1,000-gallon septic tank at the location shown on
the site plan. Work also includes the construction of a new 36' long X
3' wide X 8' effective depth absorption trench at the location shown.
The distribution line in the trench will be placed at 2' below the existing
ground surface. Total depth of the trench will be 10' below the existing
ground surface. A minimum of 3' of cover is required above the
absorption trench to protect against frost penetration. All components
of the septic system must be placed a minimum of 100' from all wells
in the area. A Zabel Flow Diverter Valve will be placed and the
existing absorption trench tied into the new system for future use.
Construction shall be in accordance with 'the approved site plan,
design drawings, Municipal Permit with any spe. cial previsions or
conditions, and all applicable State and Municipal Wastewater
Disposal Regulations.
The Contractor shall be responsible for obtaining all underground utility
locates and for the layout of the septic system and verification of the
location of all lot lines.
Unless specifically agreed otherwise, the contractor shall be
responsible for final grading areas subsequently depressed from soil
settling. Property owner shall be responsible for revegetation of
affected areas unless specifically agreed otherwise.
Contractors installing wastewater disposal systems must be certified
by the Municipal Department of Health and Human Services for
system installations. Owners installing their own systems must receive
prior approval from D.H.H.S. before beginning system installation.
SEPTIC TANK INSTALLATION
1. A new 1,000-gallon septic tank must be procured from an approved
source and installed at the location shown.
A septic tank is to be constructed by a certified septic tank
manufacturer. Construction shall include two 4" cleanouts for pumping
access.
3. The septic tank shall be sufficiently bedded to prevent settling or
shifting of the tank.
4. All standpipes on the septic tank shall extend a minimum of 12 inches
above final grade.
5. Tanks installed without 4' of cover shall have a minimum of 2" of direct
burial insulation.
· · - · Lot 21, Block I, Knik Heights
June 5, 2001
Page 2 of 3
6. A foundation cleanout shall be installed one to four feet from the
building foundation. Two cleanouts are required between the tank and
the drainfield.
7. Final grading over the tank shall be such that a positive slope exists
away from the septic tank.
DRAINFIELD CONSTRUCTION:
The drainfield shall be constructed to the dimensions shown on the
design. The bottom of the trench shall be within 2" of level.
Distribution piping must be placed level with perforations down atop a
level bed of drainfield rock. Rock should then be placed over the pipe
to provide a minimum of 2" of cover.
A silt barrier or geotextile fabric must be placed between the drainfield
rock and the natural soil backfill.
Monitor tubes must be 4" in diameter and installed at the locations
shown on the design. The portion below ground must be perforated.
Contractor shall verify the septic tank and drainfield are a minimum
100' away from any private water wells in the area, 150' from a Class
"C" Well or 200' from any community well.
Direct bury insulation must be placed over the distribution system if
less than 3' of backfill depth is available. Finish grade over the trench
must be mounded to prevent settlement or depressions.
Grade area surrounding the absorption trenches to drain away.
A minimum 2' of accepting soil is required below the drainfield rock for
a 5' wide trench. Contractor shall verify this condition prior to
placement of the rock. All pockets of unacceptable materials must be
removed and replaced.
MATERIAL SPECIFICATIONS:
1. Septic tanks must be constructed by a municipally approved septic
tank manufacturer.
2. The following pipe materials are approved for use in septic system
installations in the Municipality of Anchorage:
Cast Iron (perforated and solid), ASTM D3034 or P.V.C. (perforated
and solid), ASTM F810 or H.D.P.E. (perforated, but not solid) and
ASTM D2662 or A.B.S. (perforated and solid).
Insulation shall be at least 2" thick extruded direct burial polystyrene
(Dow Chemical Co. Styrofoam HI or equal).
Septic tank inlets and outlets shall be fitted with watertight couplings
(Caulder, Femco, or equal).
· · .Eot 21, Block I, Knik Heights
June 5, 2001
Page 3 of 3
5. A permeable geotext!le fabric (Typar, Mimfi or equal) must be installed
· between the final dram rock layer and the native soil layer.
6. All drain rock shall be .5" to 2.5" in diameter with less than 3% passing
the #200 sieve.
INSPECTIONS:
Municipal Ordinance requires a minimum of two inspections. These
inspections must be conducted under the supervision of a professional
engineer registered in the State of Alaska. The first inspection must be
conducted after the excavation of trenches, beds or pits and before the
installation of any gravel. A septic tank may be set in place, but may not
be bacld'illed.
The second inspection must be conducted after the placement of the
geotextile fabric, gravel, distribution piping, standpipes, cleanouts and
insulation. No backfill should be in place at the time of inspection.
Contractor shall provide a copy of all field survey layout and construction
notes for use in preparing the certified as-built of the completed system.
GRE,'
ANCHORAGE AREA BOR. :
Department of Environmental Quality
3330 C Street
Anchorage, Alaska 99503
INSPECTION REPORT ON-SITE SEWAGE DISPOSAL SYSTE/~
NAME re ;~F, c ~'" ~!'- .': C ,:-: MAILING ADDRESS /';'¢' · .... PHONE
-/
LOCATION LEGAL DESCRIPTION /~ --, ,' /-'~'"' --/ , /~ ;'/ ,"/F / 7'
SEPTIC TANK:
DISTANCE
FROM WELL
INSIDE LENGTH
, %~' , , _ ,, NUMBER OF
MANUFACTURER ~' '., ,'",,~ / MATERIAL / //~9//¢ COMPARTMENTS /
__ INSIDE WIDTH LIQUID DEPTH LIQUID CAPACITYz-~-*.--''''' 'GALLONS.
TILE DRAIN FIELD:
DISTANCE FROM WELL /;/¢
NUMBER OF LINES
ABSORPTION AREA
DEPTH: TOP OF TILE TO FINISH GRADE [: MATERIAL BENEATFI TILE%~J~__i~!. ABOVE TILE
TOTAL LENGTH
_FOUNDATION t[-' 7 _NEAREST LOT LINE //fi ¢ OF LINES "/J%
DISTANCE BETWEEN LINES /,? //<) _'TRENCH WIDTH ,')~'~'IN. TOTAL EFFECTIVE
SQ. FT. LENGTH OF EACH LINE
DEPTH OF FILTER
WFLL:
TYPE ~.r/,,/ '
BUILDING
FOUNDATION
CESSPOOL _
APPROVED
_CONSTRUCTION
NEAREST
LOT LINE
OTHER SOURCES
DISAPPROVED__
NEAREST
SEWER LINE
_.__REMARKS
DEPTN _
SEPTIC SEEPAGE
TANK__, SYSTEM
DISTANCE FROM:
DISTANCES:
DIAGRAM OF SYSTEM
INSTALLED BY: /~t,,/i' /
/i
SEWER LINE DEPTH:
PIPE MATERIAL: ~J'.? t i;';,¢,'I
LOT SLOPE:
REMARKS:
,/
G.A.A.B. )
Form EQ-032
GREATER ANCHORAGE AREA BOROUGH / '
/ fPi~5~F/I I T NO
DEPARTMENT OF ENVIRONMENTAL QUALITY / '~ '
TELEPHONE 274-4561 ~'~
SEWAGE DISPOSAL SYSTEM -- APPLICATION AND PERMIT
NAME Of APPLICANT
INSTAL. LATION LOCATION
LEGAL DESCRIPTION
INSTALLATION OF: SEPTIC TANK
TYPE AND SiZE OF FACILITY TO BE SERVED
FINANCED THROUGH
SOle TEST RESULTS ~-' - ~OT~:l THl~ PERMIT 1~ NOT VALID WITHOUT 5OIL TE8~
SEPTIC TANK SIZE./~_ 2____.~/,.:.~.~% TYPE ¢/~'?'~-/>/~//¢~:'/ SEEPAGE AREA SIZE
FOUNDATION TO SEEPAGE PI~
SEPTIC TANK TO SEEPAGE PIT WALL
TO NEAREST LOT LINE.
WELL TO SEPTIC TANK //¢//) ~/~ , SEEPAGE Pit
DRAIN FIELD ALSO CONSIDER AREA WELLS.
SEPTIC TANK, // ~.2 SEEPAGE PI-~ //¢¢/,/J , DRAIN FIELD
CAST IRON INTO AND OUT OF SEPTIC TANK AND INTO CRIB CROSSING GAP Of
EXCAVATION 5 FEET INTO UNDISTURBED SO[L,
4 INCH DIAMETER CAST IRON SIPHON PIPES ON SEPTIC TANK AND SEEPAGE PIT
FITTED WITH AIRTIGHT REMOVABLE CAPS.
TYPE
GRAVEL BACKFILL
CONFORM TO BOROUGH REGULATIONS REGARDING INSTALLATION.
OR
LICENSED DESIGNER
CERTIFY THAT I AM FAMILIAR WITH THE REQUIREMENTS Of GREATER .~ANC. pKAGE AREA BOROUGH ~prDI O. 28-68 AND THAT THE ABOVE
The sediments were
fairly compact with
]_ow to moderate moist..
t~_re conte~t~ ~here
a moderate cobble and
were some erxaeie Gw
accounted for less than~
]~ of the total
MUNICIPALITY CF AN'CHORAGE
DEPT. :::: ,
ENVIRON ~, L,
MUNICIPALITY OF ANCHORAGE
Department of Health & Human Services
DIVISION OF ENVIRONMENTAL SERVICES
343-4744
CERTIFICATE OF INSPECTION FOR HEALTH AUTHORITY APPROVAL OF
ON-SITE SEWER AND WATER FACILITY FOR SINGLE FAMILY DWELLING
"~ ~ ~' ('~, ~ -.. / z' ·
1. GENERAL INFORMATION (Must be completed prior to submittal)
(a) Legal Description (include lot, block, subdivision, section, township, range)
Location (address or directions)
(b) Property owner
Mailing Address
(c) Lending Institution
Telephone: (home)
Telephone
Mailing Address
(d) Real Estate Company and Agent
Address
Telephone
(e) Mail the HAA to the following address: (or check here ~ if hold for pick up.)
List contact person and day phone number below:
2. TYPE OF RESIDENCE
Single-Family~ Number of bedrooms
3. WATER SUPPLY
Individual Well'r~ Community [] Public []
Note: If community well system, must have written confirmation from the State Department of Environmental
Conservation attesting to th legality and status.
4. SEWAGE DISPOSAL
On-site¢ Public [] Community [] Holding Tank []
Note: If community well system, must have written confirmation from the State Department of Environmental
Conservation attesting to the legality and status.
72-025 (Rev. 7/88) Page 1 of 2
5. ENGINEERING FIRM PROVIDING INSPECTIONS, TESTS, FILE SEARCH, DATA AND INFORMATION
As certified by my seal affixed hereto and as of the validation date shown below, I verify that my investigation of this
Health Authority Approval shows that the on-site water supply and/or wastewater disposal system is safe,
functional and adequate for the number of bedrooms and type of structure indicated herein. I further verify that
based on the information obtained from the Municipality of Anchorage files and from my investigation and
inspection, the on-site water supply and/or wastewater disposal system is in compliance with all Municipal and
State codes, ordinances, and regulations in effect on the date of this inspection.
Address ~ 7~ ( cd_../. /~ ? ppi ~'Pt/
Date
Engineer's Seal
6. DHHS APPROVAL
Approved for -~ bedrooms by
Approved ~/~ Disapproved
Terms of Conditional Approval
Conditional
The MunicipalityofAnchorage Department of Health and Human Services (DHHS) issues Health AuthorityApproval
cerificated based only upon the representations given in paragraph S above by an independent professional engineer
registered in the State of Alaska. The DHHS does this as a courtesy to purchasers of homes and their lending
institutions in order to satisfy certain federal and state requirements. Employees of DHHSdonotconductinspections
or analyze data before a certificate is issued. The Municipality of Anchorage is not responsible for errors or omissions
in the professional engineer's work.
72-025 (Rev. 7/88) Back Page 2 of 2
Well C~s~ t'td a~'i o n
Well Log Present (Y/N) ~
MUNICIPALITY OF ANCHORAGE (MOA)
Health Authority Approval (HAA)
CHECKLIST- FEBRUARY 1984
343-4744
Legal Description:
Date Completed
Total Depth / ~ ?
Static Water Level
... Cased to / ~7
Depth of Grouting _
Casing Height Above Ground _
Electrical Wiring in Conduit (Y/N) ,~/
SEPARATION DISTANCES FROM WELL:
To Septic/Holding Tank on Lot iL~
To Nearest Edge of Absorption Field on Lot
To Nearest Public Sewer Line _
To Nearest Sewer Service Line on Lot
Water Sample Collected by
Water Sample Test Results
Pump Set At
'~o
Sanitary Seal on Casing (Y/N)
Depression Around Wellhead (Y/N) /'"/
To Nearest Public Sewer Cleanout/Manhole
; On Adjoining Lots
; On Adjoining Lots
; Date
Comments
B, SEPTIC/HOLDING TANK DATA w/~ ~.7~27~76~
Date Installed / Size ID. fro No. of Compartments
Standpipes (Y/N) O k~ ~ Air-tight Caps (Y/N) ?'
Depression over Tank (Y/N)
Pumping/Maintenance Contact on File (Y/N)
Holding Tank High-Water Alarm (Y/N)
Foundation Cleanout (Y/N)
[)ate Last Pumped .~¢--~¢'~ ?~) /.~
/
;for
Temporary Holding Tank Permit (Y/N)
SEPARATION DISTANCES FROM SEPTIC/HOLDING TANK:
To Water-Supply Well
To Property Line
To Water Main/Service Line
To Stream, Pond, Lake or Major Drainage Course
Comments
To Building Foundation
To Disposal Field
IVo ~ ~
72-026 (Rev 7/88) Fronl Page 1 of 2
C. ABSORPTION FIELD DATA
Soils Rating in Absorption Strata
Date Installed ~///¢Z~:;%
Width of Field ~:~ ri
Type of System Design
Length of Field
Depth of Field
Square Feet of Absortion Area
Depression over Field (Y/N)
Gravel Bed Thickness /¢'
Results of Last Adequacy Test
SEPARATION DISTANCE FROM ABSORPTION FIELD:
To Water-Supply Well
To Building Foundation
Lot
To Water Main/Service Line
To Stream, Pond, Lake, or Major Drainage Course
To Driveway, Parking Area, or Vehicle Storage Area
Comments
fO ~ To Property Line 1.~ ~
To Existing or Abandoned System on
; On Adjoining Lots .> ~.5'o
~ ~5' To Cutback (if present) /%/¢-~ e.
D. LIFT STATION
Date Installed
Size in Gallons
"Pump On" Level at
High Water Alarm Level at
Tested for
Meets MOA Electrical Codes (Y/N)
Comments
Dimensions
Manhole/Access (Y/N)
"Pump Off" Level at
Vent (Y/N)
Pumping Cycles during Adequacy Test.
**Check Permitted Bedroom Rating Against HAA Request**
I certify that I have checked, verified, or conformed to all MOA and HAA guiCelines,.~i,n effect on the date of this
Signedinspecti°n'"~? ' ~ -=.~-~----' ~ .~_~ ~'~'-~ F;:..', . '" ;' -- ~,,
Company
Date
MOA No.
72 028 (Rev. 7/88) Back
,r: ";-.,
Receipt No.
Waiver Fee: $
Date of Payment
Page 2 of 2
Engineer's Seal
At~CHORAGE, tll. hSKA ?9502-.ti~0-q
(907} 248-509,5
RES ]:DENT I ~qL W_~_.L_L_
LEE~AL:
LOC~T I Obi:
OWNER:
TYPE OF WELL:
WELL LOG AVAIL. ABLE: Yes
I NSTALLAT 101',1 REQU I REMENT~ MET: Y(:,~
WE::LL. YIELI) F'F,:I]Pl WELl_. LOG:
PtJMP YIELD FROM TES'I:
DA'I'IF. OF INSPECT I []hl:
TEST PROCEDURE:
pi, okic.:,. At L'.he b(.:.:,c.!ir'w~ir%} c).f tha, 'Ll~sk iht::.? ~-,~,a'ki:.)r' ]l.a, vt:?l was .{:l::)und a'L
t:)t:;.~l.''' mil~u'ke? tht.) wa'kEq'" ]. <~, v e? ]. dr'c)t:)[]a)d 'kc) :l.l:].:}~ .~:(.?ux)'k a.~:'l'.i.~H
;[l'l(.J~ a'.'~rl a'tdd:~.'k:ic~lh~,;~]. 66 minutt:~s, A tcrkal o{: 500 ga]lc:,ns
TEST FOR E.t~I]L]: AND '¥rATAL NITROGEN: I,,Ja'L:(?n,- ~.~a!;:. 'Le~;ta, d .{.c)r I~:.Co:!:i.
kotal n J kri::Kj(.:~r~ or'~ /}e.~(::: ,, ',?.2, 1990
E. C(::O. :i, (). 'f'~::rka~]. I~]J. 'kr(:)cjJm'l O..'45mF}/1 ,,
Max. a]. :1. o~ab i e
'll'r(~? IYh.ui:i, (::::i. pal rei::lUi r{{..xne.~,nt .for ~a~.CI, ]. ,{: :[ i::)w :i s :i 50 qa].
per" I::~e(::lr"ocml per' day,, This ~.,,~...~].1 exceed t.'.l~J.s r'i,:-x:luJreme:rL.
c:ondJ, kJ.c~ns ag; o'f: kl"[a~ clay Li~)!~i'k(<,(:J,, 'l'lle f:].o~,J r"at(-:.~ may
aclu:/. '{:c)r -f:[,:q::.~dJ n;~] 'l. hl,,.:, va:.;)]. 1 .
675! N, DJHONQ 8LVQ.
hNCHQRAGE, ALASKA 99502-5904
(907'/ 248-509',i
LEGAL:
LOCAT I ON:
ti WNER:
RE~ I DEN(]E:
WELl_:
:1. :)!;O/:I.C) SI~c:.~,].
I:::'i'" :i. v a (: e:.:, a (::J~ '~ <..~ :i, t I?
SEF"I'IC SYSI'IEM:
I::ROM HUI',I I E.: l I::'P,I... I:;:1~;C01::;3:)S: 4 Be{::lr"
TANK: Suns~: Plastxic: :!.2D()
ABSORF"I' I E)lq SYS'I I:~:H ~ 'l"r c.?~ Icl I
ABSOI::II::'T ION AREA= 900 Sq,, F't
SO I I... RA '111,tl3: 22',5
II'qSIAI..J..AI']:ON DA]E: July
I)A'TE OF: LAST PUMF'IN[-]: Se)l;~'l.'.,, :i. 99C) It~aacs
DA1-E OF: TEST:
'rEs'f' PROCEDURE: Sy!~-I:.l:...:,m was :~.~lSl:U:.:.:,ci:l~:,d a~il::l
.t.:Ol,' {:'. l'i (a:, {: l" i::~l"t c: h ,, "~'l'l~ clean (::lu'L ~,.¢as
::J.t,.tCll,~6,:,~ '[.["[(:o~ ~il..lllil:3 l'.¢~:~:5 Iii(]Fl.::: [:J-I~'~li ;J.J,.:: -}:e.(,e:,~: (Jt,.]l:.:?f.). The wa'L~;,:,r l(:,:,w,::,:l, was
~7'E}i' I::)~:?]ciw i:(::)p (::l't': p:[p(.:,,, ]:::'j.t::l(..:, 6?xi](;.211i;'lc-:~d
t;:;C)C) qal l(:His c:r/: c:].e, an wa['~:?r was
thC:,.' b~aL[E'l" ]. (F:,VIF,)]. ti:) r J. ~i(:i;, ~,:~. '..'J :[ I](:;lic.'.~!~i pt,.?l" :t. ()O I. fEi). ~[ (]l'l~i J. I/ the::, ~51,.uiif:) ,,
wh:i.]c.:.) i'lo v,Jat(er' rise wa~;~ (.:~bservibd :i.n
liJoli:i.i:cH"ecl .i:ol" c20 Ifi:[l'lLt'J;:i.e%. i)t,,tr:i.i]cj 'l:lle '{::~r"~it. t6¢1i fIi:J. FII..Vt:.t~:,~i; '(.'.lie vv,:~ter
1 (.,:,v(-:~l dl"Cll::il::~ed 1 J.¢lc::li, 'tthel'l i t drol:~ped a~t ach::l J. t J (::H'u~l 4 :i. r~(;::lies ,,
:i n(::lJ cat :i. ~1(~l Lha'L mc::,Fe.) I:.l~a~i :,'.~'.['i(::) gal
I:) E~F" ]. CICJ ,,
NOTE ]"l~e I::)pe~,r'a'l.:i. (:)lla:l. I :i. ";:e..~ o.~: a:l. 11. sepk:i. <::: ~ys'Li~:.:,ms de:,t:)i:)ncls [:)t'i t h(.::,
ch..u":i, r'lq '(:.l'ic) year ~ i:lr',(::l Lhe:, wai:tz:,F usaqi? o-F ~':.t'~¢~ -i:am:i. 1 y bce:i. ¢1(~1
e~st :i. mate o.t: hot,~ .I. (::~n(:l 't::ilJ s %ysl:em ~¢:t :1 1 .~:unc i: :i. on sat :i s.¢ ac tory .~:
C: LIr ~" {:¥1~ ~; (3 I" ~: LI (: t ,I I" (,.¢ I::i (:: C: I,t I:) ~::~ I~ '~: iii.
6751 ~l. I)i)II.)ND
6NCIII]R~BE, F~L~SKI~ 99502--3904
RECEIVED
dAH 1 0 19,~1
Municipality of Anc~raqe
Dept. Health & Human ~erwces
~ her.by clrtity that I have ~r~'eyed the followlr!g de~eil:~d IOrOperW, Lot~$lock. '~ :~
~'~//~,//~[~'~[/~ ~D, Ancheraa recording P~eeh~ct, Alaska, and that
.ncroach on the pro~rty lying adjacent ih~r~tO, tha~ no Imp~ov~ment~ o~ property
~'~E ' TIME TIM[:
DATE DATE DATE
,NSPECTOR ,NSPECTOR ,NSPECTO.~j~ ~
MUNICIPALITY OF ANCHORA(.:~L:
MUNICIPALITY OF ANCHORAGE DEPT, OF ','.'Ju;i
DEPARTMENT OF HEALTH & ENVIRONMENTAL PROTEC'FIq~I~VIRONME[ii,"' ;,'-[,~CTION
825 L Street - Anchorage, Alaska 99501
ENVIRONMENTAL SANITATION DIVISION APR 1_ 1_ 1980
Telephone 264-4720
ggr'Fl\/Fh
REQUEST FOR APPROVAL OF INDIVIDUAL WATER AND SEWE!I~ ~"A~II~T~'E~~'
DIRECTIONS: Complete all parts on page 1. Incomplete requests will not be processed, Please allow ten (10) days for processing.
1, PROPERTY OWNER I PHONE
I
PROPERTY RESIDENT (If different from above) PHONE
2. BUYER PHONE
MAI LING ADDRESS
3. LENDING INSTITUTION J PHONE
I
MAILING ADDRESS
4. REALTOR/AGENT PHONE
MAILING ADDRESS
5. LEGAL DESCRIPTION
STREET LOCATION
o ~ ~ F & I
~ SINGLE FAMILY ~ Two ~] Five
~ MULTIPLE FAMILY ~ Three ~] Six
7. WATER SUPPLY
~ INDIVl DUAL* * ATTACH WELL LOG. A welt Icg is required for ali wells drilled
~ COMMUNITY since June 1975, For wells drilled prior to that date, give wel
~ PUBLIC UTI LITY depth (attach log if available,) ~ C:~E ~)~q~-~
8. ~EWAGE DISPOSAL SYSTEM
~iNDiViDUAL/ON.SiTE** ~oX~ ~- YEAR ON-SITE SYSTEM WAS INSTALLED,
~ PUBLIC UTILITY
NOTE: THE INSPECTION FEE MUST ACCOMPANY EACH REQUEST BEFORE PROCESSING CAN BE NITIATED,
THIS SIDE FOR OFFICIAL USE ONLY
1. TYPE OF RESIDENCE NUMBER OF BEDROOMS
~ SINGLE FAMILY [] ONE [] THREE [] FIVE [] OTHER
[] MULTIPLE FAMILY [] TWO [] FOUR [] SIX
PERMIT NUMBER
2, WATER SUPPLY
[] INDIVIDUAL DEPTH OF WELL
[] COMMUNITY
DATE DRILLED
[] PUBLIC UTILITY
Connection Verified LOG RECEIVED
3. SEWAGE DISPOSAL SYSTEM PERMIT NUMBER
[] INDIVI DUAL/ON -SITE DATE INSTALLED
I-q PUBLIC UTILITY '-~
Connection Verified INSTALLER
[]Septic Tank or I-qHolding Tank
Size: / 1;~'O If Tank is homemade SO~LS RATING
give dimensions:
TYPE OF TANK MANUFACTURER
TOTAL ABSORPTION AREA MATERIAL
4. DISTANCES Septic/Holding Tank Absorption Area Sewer Line I Nearest Lot Line
WELL TO: '¥/~
I
Absorption Area to nearest Lot Line
5, COMMENTS
~APPROVED FOR ~ BEDROOMS
[] CONDITIONAL APPROVAL (letter must accompany certificate)
ED----- DISAPPROV ED ~_~_~
DATE ,~-- I '.~ --8 ~ BY
May 13, 1981
Graham Youl
Marston Rea
2804 W. Nor1
Anchorage,
· ISAACS PUMPING SERVICE
(Norm Tibbetts, Owner)
6218 Quinhagak Street
ANCHORAGE, ALASKA 99507
Phone 344.Ol14
CUSTOMER'8 ORDER NO. PHONE
· OF ANcHOP, AG~:
· i . C'[IoN
Re: Adequa Lot 21, Block
Knik H~
Dear Mr. Yo~
Per your re( ~e sanitary sewer
All claims and returned goods MUST be
system on th(
SERIES 609
During this ;est the liquid level in the septic Lank was monitored as water
was added to the system. The measurements are summarized in the following
table:
Time
Liquid Level Below Top
of Standpipe
Total Gallons
Added
]0:45 4.44' 0
10:47 4.44' 20
10:53 4.44' 50
11:03 4.44' 100
1]:14 4.44' ]50
11:23 4.441 200
11:31 4.44' 225
The meter used during the test was a Rockwell 5/8" standard water
which had previously been calibrated by R&IVI Consultants, Inc.
meter
May 13, 1980
Marston Realty
Page
If the 3 bedroom residence on the property is to house 6 people, the
average load on the system can be expected to be 450 gallons per day or .31
gallons per minute. During the test, the system accepted 225 gallons in 46
minutes. This indicates an average efi~luent acceptance rate of approximately
4.9 gallons per minute at the time of the test.
We can Lhere'Fore conclude that the system is disposing of efl:luent at an
adequate rate for a 6 bedroom residence.
We appreciate this opportunity to be of service to you. Please contact us if
you have any questions concerning this test or if we carl be of additional
service.
Very truly yours~
R&M CONSULTANTS, INC.
Janlic~e Cecere
P rdj~ct Manager
JC/dj/AT&SI-E
May 13, 1980 R&~'INo. 051001-29
Graham Young
Marston Realty
2804 W. Northern Lights Blvd.
Anchorage, Alaska
Re: Adequacy Test on Existing Sanitary Sewer System; Lot 21, Block I, Knik
Height Subdivision, Anchorage, Alaska. For Services Rendered through
May 13~ 1980.
Dear Mr. Graham:
The following is our invoice for professional services rendered on the above
referenced project.
Invoice No. 051001-29
Professional Services
Fixed Fee
Total Invoice No. 29
Please note our invoice number on your remittance.
questions concerning this invoice, please contact me or the Project Manager,
Ms. Janice Cecere.
Thank you,
R&M CONSULTANTS, INC.
C. J. Parisena
Anchorage Office Manager
CJP/djj/I2-F
$175.00
$175.00
Should you have any