Loading...
HomeMy WebLinkAboutEAGLE PARK BLK 3 LT 3 ,. Municipality of Anchorage Page DEPARTMENT OF HEALTH AND HUMAN SERVICES ENVIRONMENTAL SERVICES DIVISION P,O, Box 196650 · Anchorage, Alaska 99519-6650 · Telephone: 343-4744 On-Site Wastewater Disposal System and/or Well Inspection RepOrt Permit Number: c~ '70~-~ I [ PID Number: d3~"0--"7 ~ Z ~ 17' -Z,o~'IG ~L~c)¥ ~.~,3~ ~e~77 ~ ABSORPTION FIELD. //' Total Depth 7~inal g~de: LEGAL DESCRIPTION SEPARATION DISTANCES ~s.pt,~ ~ Holding ~ S.T.E.P. Line ' Remarks: BENCH MARK ENOI~ Depadment of Health and Human Se~ices approval '4;~;:... ~;..~- S~970311 AS-BUILT DRA /ING PID#, OSa-78~-17 IRON LINE ASSUNED LOCATION. EXISITING 4 DEDROON HOUSE SEPTIC TANK GENERAL LOCATION DF CRI~ AC = 30.5 Df' = 48.9 AD = 42.2 DD - 'R3.9 INVERT EL£V. nF TANK ~NLET = 93.02 INVERT ELEV. OF TANKK OUTLET = 9~.85 GROUND O~R TA~ VARIES FR~ 9~6 TO 97.6 MIN. COVER m 3 FEET AND MAX ~ER ' 4.0 FEET. TANK VAS INSULATED ~ITH 2 INCHES OF BLUEBOARD ~ ~VER IS LESS T~ ~ FEET, SEPTIC TANK UPGRAI]EI LOT 3,. IlK 3/EAGLE PARK S/II. PREPARED FOR, PREPAREI] BY, DATE* ROBERT I]AVENPORT ALASKA WATER & WASTEWATER 9/20/97 I]RAWN, GARNESS SCALE, 1' = 30' PAGE 1 OF 1 MUNICIPALITY OF ANCHORAGE DEPARTMENT OF HEALTH AND HU~ SERVICES P.O. BOX 196650, 825 "L" STREET, ROOM 502 ANCHORAGE, ALASKA 99519-6650 ON-SITE WASTEWATER DISPOSAL SYSTEM (UPGRADE) PERMIT PERMIT NUMBER:SW970311 DESIGN ENGINEER:ALASKA WATER & WASTEWATER SERVICES OWNER NAME:DAVENPORT ROBERT E & PAMELA S OWNER ADDRESS:20518 MELODY LN DATE ISSUED: 9/11/97 EXPIRATION DATE: 9/11/98 PARCEL ID:05078217 LEGAL DESCRIPTION: EAGLE PARK BLK 3 LT 3 LOT SIZE: 39600 (SQ. FT.) NUMBER OF BEDROOMS: 4 THIS PERMIT: 4 THIS PERMIT IS FOR THE CONSTRUCTION OF: SEPTIC TANK SYSTEM ALL CONSTRUCTION MUST BE IN ACCORDANCE WITH: 1. THE ATTACHED APPROVED DESIGN. 2. ALL REQUIREMENTS SPECIFIED IN ANCHORAGE ~3NICIPAL CODE CHAPTERS 15.55 AND 15.65 AND THE STATE OF ALASKA WASTEWATER DISPOSAL REGULATIONS (18AAC72) AND DRINKING WATER REGULATIONS (18AAC80). 3. THE ENGINEER MUST NOTIFY DHHS AT LEAST 2 HOURS PRIOR TO EACH INSPECTION. PROVIDE NOTIFICATION BY CALLING 343-4744 ( 24 HOURS ) (NOT REQUIRED FOR WELL ONLY PERMIT) 4. FROM OCTOBER 15 TO APRIL 15 A SUBSURFACE SOIL ABSORPTION SYSTEM UNDER CONSTRUCTION DURING FREEZING WEATHER MUST BE EITHER: A. OPENED AND CLOSED ON THE SAME DAY B. COVERED, SEALED AND HEATED TO PREVENT FREEZING 5. THE FOLLOWING SPECIAL PROVISIONS. SPECIAL PROVISIONS: RECEIVED BY: ~.~ ~'/~ ~..~ ~ _ ---~-_.~ DATE: Alaska Water & Wastewater September10,1997 8471 Brookridge Drive ~ Anchorage ~ Alaska 99504 (907) 337-6179 ~ Fax (907) 3~g-3246 Consulting Engineers Municipality of Anchorage Department ofHealth & Human Services Division of Environmental Services On-Site Services Section P.O. Box 196650 Anchorage, Alaska 99519-6650 Ret': Septic Tank Replacement for Lot 3, Bk 3, Eagle Park S/D. Eagle River, Alaska. To whom it may concern: The existing 4 bedroom house is served by private well and septic system. The existing 1250 has collapsed, and must be replaced immediately. Attached is a 1" = 30' scale drawing showing the proposed location for a new 1250 gallon tank. There are no surface waters within 100 feet of the new tank. I am unaware of any adverse impacts this installation would have on adjacent wells or septic systems. If you have any questions, please contact me at 337-6179, 244-9612, or on my digital pager at 1-800J81-1162. Thank you for your assistance. Je~.~.Sincerely' ,~ / ~ ~ Owni:r/Cor}lultant ~INSTALL T~I:]U~LE £X[ST]NG IE~50 GALLON ANO 'INSTALL N£~./ IE50 ~ALLDhl TANK, CAST IRON LINE LDT 4, ~< 3, EAGLE PARK SEPTIC TANK UPGRADE, LDT 3, BK 3, EAGLE PARK S/B. PREPARED FDR, PREPARED BY, DATE, 9/10/97 RDDERT BAVENPDRT ALASKA WATER & ~ASTE~ATER DRAWN: GARNESS SCALE~ 1' = 30' £XISITING 4 BE~RDOM HDUS£ L~]' ~, ~l( ] EAGLE PARK .aT ;~o gl( 3 EAGLE PARl( PVT. YELL AND ~EPTIE LOT 4, gK 3, EAGLE PARl( S/0. PVT. ~LL & SEPTIC. SEPTIC TANK REPLACEMENT, PREPARED FORI PREPARED DY' DATE, LDT :3, BK :3, EAGLE PARK RD]~ERT DAVENPORT ALASKA WATER 8, WASTEWATER 9/10/97 ]3RAWN: GARNESS SCALE, 1' = 100'  MUNICIPALITY OF ANCHORAGE DEPARTMENT OF HEALTH & ENVIRONMENTAL PROTECTION ENVIRONMENTAL ENGINEERING DIVISION 825 L Street- Anchorage, Alaska 99501 Telephone 264-4720 ON-SITE SEWAGE DISPOSAL SYSTEM AND/OR WELL INSPECTION REPORT ~ ~ DISTANCE TO: --Z Manufacturer ~9 o s IF HOME.DE: Inside length Width Liquid depth No. oflJn. / Length°f~hTe~ '~ ~ ~ X~ inches ~ Total eff~ti~ absorption area m Well Building foundation Nearest lot line ~ DISTANCE TO: ~ DISTANCE TO: ndatlon Se~r line Septic tank Absorption area(s) OTHER SO~ L TEST RATING INSTALLER ~e. E DATE LEGAL 72-0~,; {Rev. 3/78) PERMIT NO. I ~ I PR& I TV OF Rr~C~4ORR~S / DEPRR..TMENT,/'~ HERLTH AN~ EMVIRONMENTAL~OTECTION ~ /, ~ 825 C STREET, ANCHORAGE, AK. ~01 ~ / --{ ~- Ot~--5 [ me 5E~EE PERM ~ T ~U~"' ~' APPLICANT REED WRYCHOFF LOCATION MELODY RD LEGAL ~L~B~ £RGLE PARK BOX 54~ FR AK LOT SIZE 694-9407 40000 SQUARE FEET TYPE OF SOIL ABSORPTION SYSTEM IS: TRENCH MAXIMUM NUMBER OF BEDROOMS = 4-5- SOIL RATING (SQ FT/BR)= ~.THF REQU_IREDu~_~ ~---~ ~-~-~--i-~SIZE OF THE ~OIL ABSORPTION ~Y~TEM IS:~~~~~' THE LEWGTH DIMENSION i~ 'THE'LENGTH (IN.FEET) OF THE-TRENCH .............. OR DAR'INFIELD. THE DEPTH OF R TRENCH OR PIT I~ THE DISTANCE BETWEEN THE ~URFRCE OF THE GROUND AND THE BOTTO~ OF THE EXCAVATION (IN FEET). THERE IS NO ~ET WIDTH FOR TRENCHE~. THE GRAVEL DEPTH IS THE MINIMUM DEPTH OF GRAVEL BETWEEN THE OUTFRLL PIPE AND THE BOTTOH OF THE E~CRVRTION (IN FEETX Re(~.LI I RED SEPT I C TAIqK $ I ZE= 'l ~50 GRLLON$ PERMIT APPLICANT HAS THE RESPONSIBILITY TO INFORM THIS DEPARTMENT DURING THE INSTALLATION INSPECTIONS OF ANY WELLS RDJRCENT TO THIS PROPERTY AND THE NUMBER OF RESIDENCES THAT THE WELL WILL SERVE. TtdO (2> INSPECTIONS lire REQUIRED BACKFILLING OF ANY SYSTEM WITHOUT FINAL INSPECTION AND APPROVAL BY THIS DEPARTMENT WILL BE SUBJECT TO PROSECUTION. MINIMUM DISTANCE BETWEEN A WELL AND ANY ON-SITE SEWAGE DISPOSAL SYSTEM IS 100 FEET FOR R PRIYRTE WELL OR 150 TO 200 FEET FROM R PUBLIC WELL DEPENDING UPON THE TYPE OF PUBLIC WELL · MINIMUM DISTANCE FROM A PRIVATE WELL TO R PRIVATE SEWER LINE IS 25 FEET AND TO R COMMUNITY SEWER LINE IS 75 FEET. OTHER REQUIREMENTS MAY APPLY. SPECIFICATIONS AND CONSTRUCTION DIAGRAMS ARE AVAILABLE TO INSURE PROPER INSTALLATION. PeRM I T exP I RES DECEMBER ~_. 1~c~80 I CERTIFY THAT 1: I AM FAMILIAR WITH THE REQUIREMENTS FOR ON-SITE SEWERS AND WELLS RS SET FORTH BY THE MUNICIPALITY OF ANCHORAGE. 2: I WILL INSTALL THE SYSTEM IN ACCORDANCE WITH THE CODES. ~: I UNDERSTAND THAT THE ON-SITE SeJER SYSTEM MAY REQUIRE ENLARGEMENT IF THE RESIDENCE IS REMODELED TO INCLUDE MORE THAH 4 BEDROOMS. A~LIGRNT ._REJ~])eWRYCHOFF /- ~.' MUNICIPALITY OF ANCHORAGE DEPARTMENT OF HEALTH AND ENVIRONMENTAL PROTECTION 825 L Street, Anchorage, Alaska 99501 264-4720 SOILS LOG - PERCOLATION TEST SLOPE DATE PERFORMED. WAS GROUND WATER ENCOUNTERED? O P IF YES, AT WHAT E DEPTH? 2 3 5- 6- 8- 9- 11 I-I SOILS LOG XPERCOLATION TEST 13- 15- 16- 17- 18- 19, 20- o6' 2. 'j'.: 1457. SITE PLAN Gross Net Depth to Net Reading Date Time Time Water Drop ANCHORAGE AREA BOF'-'UGH Anchorage, Alaska 99503 INSPECTION REPORT ON-SITE SEWAGE DISPOSAL SYSTEM LOC^T,O. ~'" J' L~ $ ~ P.~ ~, LEGAL DESCR,PT,ON PHONE SEPTIC TANK: DISTANCE FROM WELl_ INSIDE LENGTH NUMBER OF MANUFACTURER .~;,,~i~K..J~ ,~&'~"Z.- MATERIAL ~T'~'~"'L. COMPARTMENTS ~" INSIDE WIDTH LIQUID DEPTH IIQUID CAPACITY /Z%--~ GALLONS. SEEPAGE PIT: NUMBER OF PITS / DIAMETER /~0' OR WIDTH '~". LINING MATERIAL ~0 (. CRIB SIZE: DIAMETER BUILDING FOUNDATION ~/ NEAREST LOT LINE ADDITIONAL ABSORPTION TYPE CONSTRUCTION BUILDING NEAREST NEAREST FOUNDATION LOT LINE SEWER LINE CESSPOOL OTHER SOURCES APPROVED DISAPPROVED REMARKS DEPTH DEPTH DISTANCE FROM: WELL TOTAL EFFECTIVE ABSORPTION AREA (WALL AREA) ~(~ · DEPTH SEPTIC TANK __ DISTANCE FROM: SEEPAGE SYSTEM DISTANCES: INSTALLED BY= PIPE MATERIAL: LOT SLOPE= REMARKS: Form No. EQ-O31 DIAGRAM OF SYSTEM I~OAD ~/G.A.A.B. GrEaTEr ANCHOrAgE ArEA BOrOUgH SEWAGE DISPOSAL SYSTEM ~ APPLICATION AND PERMIT PERMIT NO, · , ~ , /If/,_.. r m /~ ~ ~ ~m INSTAL~TION OF: 6EPTIC TANK / SEEPAGE PIT~ DRAIN FIELD . OTHER TYPE AND SIZE OF FACILITY TO BE SERVED FINANCED THROUGH / TO BE INSTALLED BY FINAL INSPECTION: 24 HOUR NOTIC£ REQUIRED, BACKFIL,ING OF ANY SYSTEM WITHOUT FINAL INSPECTION BY THE DEPARTMENT OF rNVIRONMENTAL QUALITY AUTHORITY WILL BE SUBJECT TO PROSECUTION. *,OU.OA'r~oN TO S£~,C 'rANK ~-- SEPTIC TANK SEEPAGE PIT TO NEAREST LOT LINE. · WELL TO SE~'rlC TANK /~'~ DRAIN FIELD · DRAIN FIELD WATER MAIN TO SEPTIC TANK DRAIN FIELD DRAIN FIELD R&M EN('"",IEERING & GEOLOGI("".L CONSULTANTS 229 EAST 51st. AVE. - P.O. BOX 6087 -- ANCHORAGe-, ALASKA 99503 TELEPHONE 907-279-0483 TELEX 0"~0-35419 Civil EnEineer$ Geologls~s Land iurveyo~ JAMES W. ROONE¥o Po E. ~,IALCOLM A. MENZIES, P.E., L.S. JAMES H. %NELLMANo P.E. February 7, 1974 Mr. Don Zemmerman Box 596 Eagle River, Alaska BECEIVED F gE, 1974 99577 No. 462004 RALPH R. MIGLIACCIO Re: Test Hole 'and Soil Log Report for Sanitary System, Lot 3, Block 3 Eagle Park Subdivision Dear Hr. Ze~,,erman: We are submitting herewith the test boring results and our comments regarding soil conditions encountered at the subject site. This investigation was performed in accordance with your request of February 5, 1974, and those procedures outlined in a letter dated '~ September 13, 1971 by Mr. Roll Strickland of the Greater Anchorage Area Borough Department of Environmental Quality. A single test hole was put down wtthin the Lot 3 area for the purpose of defining general subsurface soil conditions for the proposed sani- tary system. Excavation was accomplished with a tractor-mounted back- hoe and the test hole was extended to a total depth of 15.0 feet below ground surface. The final log prepared for the test hole has been included im Drawing A-01. · Ground water was not encountered in the test hole. We appreciate being given this opportunity to be of service to you. Should you have any questions with regard to the above, please do not hesitate to contact us. Very truly yours, R & M ENGINEERING & GEOLOGICAL CONSULTANTS ~/James W. Rooney . J[~R:ph xc: GAAB/ ANCHORAGE FAIRSANKS JUNEAU T.H. 1 2-6-74 ORGAMICS SILTY SAND, Trace Organics (SM) 0.0' 0.5' SAND, Trace. Silt (SP) 5,0t' SANDY SILT, (ML-SM) 7.0* SAND, Trace Silt (SP) NOTE: No Water Table Test hole excavated with tractor-mounted backhoe. 15.0' Enc]ineering I~ Geological Consultants Inc. · ,c,o~ F~mm~,,s ALASKA Ju,E~u DON ZI'I'I~IME~MAN PROPERTY LOC OF TEST ItOLE Anchorage Alaska 4-7-74 NO. 462001 iowa MUNICIPALITY OF ANCHORAGE DEPARTMENT OF HEALTH & HUMAN SERVICES Division of Environmental Services On-Site Services Section P.O. Box 196650 Anchorage, Alas. ka 99519-6650 343-4744 Parcel I.D. # CERTIFICATE OF HEALTH AUTHORITY APPROVAL FOR A SINGLE FAMILY DWELLING GENERAL INFORMATION Complete legal description · Location (site address or directions) Property owner /_~up~,/~ Mailing address Lending agency Mailing address Agent ~"~.,~.~ ~-~o Address Day phone Day phone ~-~,~"~ 2. NUMBER OF BEDROOMS: 3. TYPE OF WATER SUPPLY: Unless otherwise requested, HAA will be held for pickup. NOTE: Individual well Community well. Public water If community well system, provide written confirmation from State ADEC attest- ing to the legality and status of system. 4. TYPE OFWASTEWATER DISPOSAL: NOTE: Individual on-site Holding tank "' Community or{-site Public sewer If community wastewater system, provide written confirmation from State ADEC attesting to 'the legality and status of system. 72-02S (Rev. 1/gt) F~o~t MOA STATEMENT OF INSPECTION BY ENGINEER As certified by my seal affixed hereto and as of the validation date shown below, I verify that my investigation of this Health Authority Approval application shows, that the on-site water supply and/or wastewater disposal sYStem is safe, functional and adequate for the number of bedrooms and type of structure indicated hdrein. I further ~,erify that based*on the information obtained from the M'unicipality of Anchorage files and from my investigation and inspection, the on-site water supply and/or wastewater disposal sYStem is in compliance with all Municipal and State codes, ordinances, and regulat!ons in effect on the date of this inspection. Name of Firm D.vld R. D,,/ton P.E, Phone ~ ~ ',-~'~/7 20210 Donalar St. Address Chual.k. Engineer's signature '' ,~/'~' ~"~'~'~' Date'' ~.,/~/f,B - DHHs SIGNATURE Approved for Disapproved. __ Conditional approval for bedrooms. bedrooms,. with the following stipulations: Additional Comments Date ~'- The Municipality of Anchorage Department of Health and Human Services (DHHS) issues Health Authority Approval Certificates based only upon the representations given in paragraph 5 above by an independent professional engineer registered in the State of Alaska. The DHHS does this as a courtesy to purchasers of homes and their lending institutions in order to satisfy certain federal and state requirements. Employees of DHHS do not conduct inspections or analyze data before a certificate Is issued. The Municipality of Anchorage is not responsible for errors or omissions in the professiona! engineer's work. Municipality of Anchorage Department of Health and Human Services HEALTH AUTHORITY APPROVAL CHECKLIST Legal Description: /-~r'5 ~,~ ~ ¢::~..~ ,,~,~.~ ,Parcel I.D. A. Well Data Well type ~;~F, Log present (Y/N) Total depth / Sanitary seal (Y/N) FROM WELL LOG If A, B, or C, attach ADEC letter. ADEC water system number Date completed /~?'~ -~ Driller Cased to .,'~'~ ~"' Casing height Wires properly protected (Y/N) y Date of test Static water level Well flow Pump level1 SEPARATION DISTANCES FROM WELL TO: Septic/holding tank on lot //~ Absorption field on lot /,~.z' ~ Public sewer main ~',/,,? Sewer service line g.p.m. AT INSPECTION ; On adjacent lots ; On adjacent lots Public sewer manhole/cleanout Petroleum tank WATER SAMPLE RESULTS: Coliform ~?,~ ~, ~ , Nitrate Date of sample: ~,,/~./~ _'~ Collected by: B. SEPTIC/HOLDING TANK DATA Date installed / ~?~/ Tank size / Z.~'Z~ Compartments Cleanouts (Y/N) Y Foundation cleanout (Y/N) ~ Depression (Y/N) High water alarm (Y/N) ,,~,,/./~' Alarm tested (Y/N) ' Date of pumping ~'/~'/~,-~ Pum pe ;' '; ' ~',,~; r'~'~,· SEPARATION DISTANCES FROM SEPTIC/HOLDING TANK TO: Well(s) on lot /ifil To property line Surface water/drainage .On adjacent lots i oo,-{-- Foundation '/'11 ~ Absorption field -Z-c> Water mc!."Jservice line <~'~ CONTINUED ON BACK PAGE C. LIFT STATION Date installed Size in gallons Vent (Y/N) .'Pump on' level at Manufacturer Manhole/Access (Y/N) "pump off" Level at High water alarm level Meets MOA electrical cedes (y/N) Cycles tested SEPARATION DISTANCE FROM LIFT STATION TO: Well on lot D. ABSORPTION FIELD DATA · Date install~ '~1~ To~l ab~fion area Date of ad~ua~ test Wate~ level in abso~tion field before test Peroxide treatment (past 12 months) (y/N) On adjacent lots Soil rating (GPD/Ft Gravel thickness Cleanout present (Y/N) Surface water System type ,5' ~'~,'-~ ~.~ Total dep~ ~ ' Depm~ion ~er field ~) for ~ ~dr~ After test ~ ~ If yes, give date SEPARATION DISTANCE FROM ABSORPTION FIELD TO: Well on lot To building foundation On adjacent lots Surface water Curtain drain On adjacent lots /~ ~ (- .Property line · ?o To existing or abandoned system on lot Cutbank ,u'o~'~ Water-mei~/sewice line Driveway, parking,~,ehicle storage area z/z~o E. ENGINEER'S CERTIFICATION I certify that I have checked, 'verified, or conformed to all MOA and HAA Signature Engineer's Name Date David I~ Dayton 20210 Dona]erSt. HAA Fee $ Date of Payment Red,pt Number guidelines in effect on the date of this inspection. Waiver Fee $ Date of Payment Receipt Number. 72-026 (3/93)' Back D. R. DAYTON, P.E., R.L.S. ~.~x~:~ Chugiak, Alaska 99567 20210 Donalar 696-2417 June 4, 1993 ADEQUACY TEST Legal Description: Lot.{3, Blk 3, Eagle Park Subdivision Date of Test: June 3, 1993 Septic Tank: 1250 gallon, 2 compartment, steel tank Absorbtion System: log crib (25' x 25' x 6') with additional 61'x2%'x6' trench. Soils: 181 sq. ft. per bedroom Reqiurements: 4 bedroom - 600 gallons per day (DHHS Records) (DHtID-Records) (DHHS Records) TE. ST: Water was injected into the absorbtion system while monitoring volume, time, and rise in liquid l~vel. After injection was stopped, the water level was measured at 10 minute intervals. The results were plotted an'a graph of time and gallons absorbed. RESULTS: The septic system is currently functioning adequately for a 4 bedroom home. D. R. DAYTON, P.E., R.L.S. ~t~[EI~J~ Chugiak, Alaska 99567 20210Donalar 696-2417 WELL FLOW TEST: Legal Description: Lot3, Blk 3. Eagle Park Subdivision Date of Test: June 3, 1993 Well Depth: 110 ft. per municipal records Static Water Level: 88' Requirements: 4 bedroom - 600 gallons per day TEST: The well was pumped through an outside hose bib for 2 hr 30 min. The well produced 629 gallons at an average rate of 4.2 gallons per minute. RESULTS: The well is currently producing adequately for a 4 bedroom home. From --' By JR's PUMPING 16718 ~ercy Drive s-i'L: . · '.';4 8501 COMMERCIAL TESTING & ENGINEERING CO. ENVIRONMENTAl. LABORATORY SERVICES · .c,,~ P~T Of ANALYSIS Chemlab Ref.# :93.2537-1 Client Sample ID :L3 B3 F~GLEPARK S/D Matrix :WATER $~3 B STREET ANCHORAGE," AK 99518 TEL: (907) 562-2343 FAX: (907) 561-5301 Client Name :DAVID DAYT~DN, P.E. WORK Order =66783 Ordered By :DAVID R. DAY~N Report Completed :06/07/93 Pro~ect Name : Collected :06/02/93 @ 20:00 hrs. Project# : Received :06/03/93 @ li:30 hrs. PWSID :UA Technic~Ll Director:STEP~ C. EDE Released By Sample Remarks~ ROUTINE SAY~LE CO[3.FCi~U BY: D.R.D. QC Allowable Ext. ~ Parameter ~ Results Qual Units Method Limits Date r~te Init Nitrate-N 2.95 mg/L EPA 353.2/300.0 l0 06/04 L~ * See Special Instructions Above UA = Unavailable ** See Sample Remarks Above NA = Not Analyzed U = Undetected, Reported value is the practical quantification limit. LT = Less Than D = Secondary dilution. GT = Greater Than ENVIRONMENTAL SERVICES IN ALASKA, COLORADO. UTAH. ILLINOIS. OHIO, MARYLAND, WEST VIRGINIA, NE1N JERSEY, SOUTH CAROLINA o . ' COMME, R, CIAL TESTING & ENGINEER~.~G CO. AK DIV CHEMICAL & GE~OLOGICAL LAB?RATORY :' 'TELEPHONE (907) 562.2343 5633 B Street TO BL~COMPLETED BY WATER s~PPLIER Anchorage. AJaska 99518. Drinking Water Analysis Report for Total Coliform Bacteria I~ TO BE COMPLETED BY LABORATORY r'l PUBLIC WATER SYSTEM I.D. # ~ PRIVATE WATER SYSTEM Mo. Day Year SAMPLE TYPE: ) I-1 Treated Water ,~ Untreated Water 'l~]~outlne CI Check Sample (for routine sample with lab ref. no. I'1 Special Purpose 'nme Collected I I I I SAMPLE No. LOCATION 21 31 41 si Analysis shows this Water SAMPLE to be: ,,,~ Satisfactory n Unsatisfactory n Sample too long In transit; sample should not be over 30 hours old at examination to Indicate reliable results. Please send new sample via special dallvery mail. Date Received Time Received / Analytical Method: Membrane FlEer ' No. of colonies/100 ml. Lab Ref. No. Result* , ,~ ~.~;-2 I-F1 I~ I I~ Analyat A .D .E.C. (,~-'/-~ ,'Nde- READ INSTRUCTIONS BEFORE COLLECTING SAMPLE BACTERIOLOGICAL~IS RECORD ....b..n..,,.,:.,.ec, Cou.,' ,"''~-[~ '~ ~'"'~.,~,oo,., Verlflcltlon: I.~B ' ~ ~"'-' Fecal Coliform Conflrmetlon TNTC = Too Numerous To Count OB = Other Bacteria Flnll Membrane Filler Reaulte ¢~ Collfoml/100 mi ".,-.ed', ~¢- ///'--' ~.,. ~.m. ~,,~ S ~-~ Member of ti PART ONE OF TWO REHAINDER TO FOLLOW COMMERCIAL TESTING & ENGINE,ERING CO. AK DIV CHEMICAL & GEOLOGICAL 'I.~4BORATORY .' TELEPHONE {907) 562.2343 5633 B Street Anch~'age, Alaska 99518. Drinking Water Analysis Report for Total Coliform Bacteria TO BE COMPLETED BY WATER SUPPLIER UI PUBLIC WATER SYSTEM I.D. # /,~'PRIVATE WATER SYSTEM Name Mo. Day Year SAMPLE TYPE: /~]~Routlne [:] Chock Samplo (for routine sample with lab rsf. no. I-I Special Purpose ) I-I Treated Water ~ Untroated Wator SAMPLE 11me Collected No. LOCATION Collected I 31 I "1 I TO BE COMPLETED BY LABORATORY Analysis ~hows this Water SAMPLE to be: /~,Satisfactor/ n Unsatisfactory r'l Sample too long in transit; sample should not be over 30 hours old at examination to Indicate reliable results. Please se~d new sample via special deliver/mail. · Pard Rsc*lved ~/{Z~ '.m, .,c.~ved · \ \ gO Analytical Method: Membrane Flitor · No. of colonies/100 mi. Lab Ref. No. Result' . 30/)144 FT] I F-Fq I m Analyst READ IRiSTRU'CTIONS Membrane Flller: Direct Count BEFORE Verification: LSB Fecal Coliform Conflrmallon COLLECTING SAMPLE Final Me~nbrane Filler Results · Reported By ~'~-~- ~ TNTC = Too Numerous To Count BAC'FERIOLOGICAL WATER ANALYSIS RECORD ~ Coliform/100 mi Coliform/100 mi OB = Other Bacteria p.m. ~ -I~G-~ Member Da' Ihs SGS Group (Soci~t~ G6n6rale de Su~eitlance) ' ~ APPLIC~.T FILLS OUT UPPER HALr'~NLY Buyer Address Zip Type of .es[~nce ~ Multiple Family NO. of ~ Other ~ ~mm~lty For wells ~llled prior to that date, give well depth (attach I~ If available). ~ Public Utility ~ Public ~illty When ~ected to Public Utility: NOTE: THE INSPECTION ~E MUST ACCOMPANY EACH RE~EST BEFORE ~OCESSING CAN BE INITIATED. Time Time Time Time Date Date Date Date Inspector Inspector Inspector Inspector Field Notes: ~_l ~,~,~ ( ~DB~DROOMS. ~ *CONDITIONSOFAPPROVAL { ) DISAP~OVED ~" Soils Rating Date ~wer Installed Well To ~sorptlon Atoi Well Log Received EXCAVATION WORK Dynamic Realty ATTENTION: Linda Parker P.O. Box 1796 Eagle River, Alaska 99577 Dear Linda, July 31, 1983 ROBERT A. SHAFER CIVIL ENGINEER 694-2979 AUG 1 1983 "Municipality of A~.chorag~" "Dept. of Heal[l~ & [~¥t[o~m~rttal P~ot~ctlcn" Reference: Lot 3: Block 3% ~agle Park Subdivision · A sewer system adequacy test was performed on the system located on the referenced property as you requested. The septic tank was pumped and verified to have a capacity of 1000 gallons. The combination seepage pit and trench was tested by a continuous flow of water over a period of 48 hours. The average flow during this time exceeded the requirement for three bedrooms. It can be concluded from this test that the waste water disposal system serving the three bedroom residence located on this property is currently functioning adequately. However the system cannot be guaranteed against subsequent failure. It should be noted during the initial inspection that the septic tank lacked adequate fill over the top of the tank. On the final inspection of the adequacy.test it was noted that adequate fill had been placed over the top of the tank. If we may be of.f~ther service, / ROBERT A. SHAFER, P.E. CC: Municipality of Anchorage Department of Health and Environmental Protection please do not hesitate ~o call. SRB 196X EAGLE RIVER. ALASKA NWWA CERTIFIED PUMP INSTALLER 2% Discount If paid In 10 days '" · Addre~ ' ~ . - Qty. ~ · ~scrlptlon Price Amount Receiv~ In Satisfacto~ ~ndition TOTAL · Please pay by Invoice. All accounts Past Due will bo charged 1 Yf %. THANK YOU * - ~ 3ATE RECEIVED ~ -" INSPECTION APPOINTMENTS I. RIME TIME TIME DATE DATE DATE MUNICIPALITY OF ANCHORAGE DEPT. OF H~L~ & ~ DEPARTMENT OF HEALTH & ENVIRONMENTAL PROTECTI~IRO~E~ PROTE~ION  ENVIRONMENTAL SANITATION DIVISION RECEIVED flEOUEST FOil APPROVAL OF INDIVIDUAL WATE~ AND ~EWEB FAOlLITIES 4. REALTO~ENT PHONE ' MAILING A~DRESS 6. TYPEOF RESIDENCE NUMBER OF~BEDROOMS r-I One ~ Four ~ SINGLE FAMILY I--I Two [] Five [] MULTIPLE FAMILY [] Three r-I Six [] Other 7. WATER SUPPLY INDIVIDUAL* [] COMMUNITY [] PUBLIC UTI LITY 8. SEWAGE DISPOSAl. SYSTEM ~ INDIVIDUAL/ON-SITE** [] PUBLIC UTILITY A'I-rACH WELL LOG. A well log is required for all wells drilled since June Ig75. For wells drilled prior to that date, give well depth (attach log if available.) f/~¢t9 I . ~/~ YEAR ON-SITE SYSTEM WAS INSTALLED. NOTE: THE INSPECTION FEE MUST ACCOMPANY EACH REQUEST BEFORE PROCESSING CAN RE INITIATED. · I , _ " ¢,'~e ~-e.c,.~ '.-.-.'," .,~/.z...,-¢--',-. - .,~ TYPE OF RESIDENCE D SINGLE FAMILY I-'1 MULTIPLE FAMILY 2. WATER SUPPLY D INDIVIDUAL [~] COMMUNITY I'-I PUBLIC UTI LITY Connection Verified 3. SEWAGE DISPOSAL SYSTEM I'-IINDIVIDUAL/0N ~ITE I-'IPUBLIC UTILITY Connection Verified r--ISeptic Tank or [--IHolding Tank Size: ~--~'~ If Tank is homemade give dimensions: TYPE OF TANK THIS SIDE FOR OFFICIAL USE ONLY NUMBER OF BEDROOMS [] ONE r-I THREE r-'l FIVE [] TWO [] FOUR I--I SlX [] OTHER TOTAL ABSORPTION AREA 4. DISTANCES WELL TO: Absorption Area to nearest Lot Line 5. COMMENTS PERMIT NUMBER DEPTH OF WELL DATE DRILLED LOG RECEIVED PERMIT NUMBER DATE INSTALLED INSTALLER SOILS RATING MATERIAL ~eptic/Holding Tank IAbsorption A~'ea ISewer Line I]~'APPROVEDFOR '~ BEDROOMS I'--I CONDITIONAL APPROVAL (letter must accompany certificate [] DISAPPROVED '' ~ ' d'_ DATE 72-010 (Rev. 6/79) Drinking Water Analysis Report for Total Col,f0~m Bacteria TO BE COMPLETED BY WATER SUPPLIER WATER SYSTEM: Mailing Address Mo. Day'. year Zip Code SAMPLE TYPE: [] Routine [3 Check Sample (for routine with lab ref. no. [] Special Purpose [] Treated Water [] Untreated Water SAMPLE NO. LOC~TION 2 Time Collected Collected By I TO BE COMPLETED BY LABORATORY Analysis shows this Water SAMPLE to be: I~ Satisfactory [] Unsatisfactory [] S;~mple too long in transit; sample should not be over 48 hours old at examination to indicate reliable results· Please send new sample, Date Received ~ - ~ '~ ' ~;'~) Time Received / ~:~ L) An:~lytlcal Method: C] Fermentation Tube · . ,1:3 Membrane Filter Lab Ref. No. Result* Analyst. 15~?co_,./?I ~ /;s ~,'/ I II"T'I/ I II-[3 I IF-~ READ INSTRUCTIONS BEFORE COLLECTING SAMPLE 0~-]220 BACTERIOLOGICAL WATER ANALYSIS RECORD Kr. Paed :~'oychoff B~× 5~33 ' ; Als s'~:a Ft. Dear I.h-. 1.hy~hoff, OAVIO A, SLENKAMP ROBERT A,$HAFER October 1, 1980 P~ference: Lot 3; Block 3; F~gle Park Subdivision; At your request, a sewer ~,steu ede~uncy test ~ns p*r£or~ned on the system serving the four bedroom residence located on the referenced property. The septic ~nk ~s p~.ped 8nd verified to hove s capacity of 1~3 ~]lons. The crib located ~tbtn the seepage pit u~s cozpletely full of ~ter. Approzin~tely 1109 gallons of %rater ~us removed from the crib end the system rechnrged with 1000 ~lons of fresh %~ter. ~en'surer. ents tnken at the end of , 24 hour period indicnted that none of the w~ter which was added to the system h~d properly percol, ted out of the crib. It con be concluded from this test that the septic ~nk is adequate. However, it appears that the seepnge pit hns failed end will reoj~ire a complete upgrading. If you req~re ,~ further assis~nce in obt, ining the proper permits and approved upgroding of the system, please do not hesi~te to c~ll. Since~ ~y, ' D3portr. ent of Healt~ and Kuviornment~l Protection Houston and Associates Lomas and Ncttleton SR8 195X EAGLE RIVER, ALASKA .-/qkhnicipality Anchorage 825 "L" STREET ANCHORAGE, ALASKA 99501 (907) 264-4111 GEORGE M. SULLIVAN, MAYOR DI-PARTMENT OF HEALTH ANO ENVIFIONMENTAL PROTECTION September 29, 1980 Reed/Wilma Waychoff Post office Box 5433 Fort Richardson, Alaska 99505 Subject: Lot 3 Block 3 Eagle Park subdivision Approval for your individual sewer and water facilities cannot be granted until the following items have been completed: (1) The water analysis report be'delivered to this department from Chem Lab, 5633 B Street, for our review. (2) The septic tank pumped with a receipt submitted to this department. (3) A four(4) inch cast iron cleanout needs to be installed %o the septic tank. 4) An adequacy test be performed on the existing leaching area. This test will determine if the system is adequate according to National Standards. A listing of private firms performing the test is enclosed. This report needs to be submitted to this department for our review. If there are any further questions, please call this department at 264-4720. Sincerely, Robert C. Pratt, R.S. Associate Specialist RcP/ljw cc: Lomas and Nettleton 4449 Business Park Boulevard 99503 unicipality of Anchor ¢ 825 "L" STREET ANCHORAGE, ALASKA 99501 (907) 264-4111 GEORGE E~I. SULLIVAN. MAYOR DEPARTMENT OF HEALTH AND ENVIRONMENTAL PROTECTION October 6, 1980 Reed/Wilma Waychoff Post Office Box 5433 Fort Richardson, Alaska 99505 Subject: Lot 3 Block 3 Eagle Park Subdivision The adequacy test performed on your sewer system failed to meet National Standards. Therefore, before approval may be granted, an upgrade will be required. The upgrace will include 75 feet of trench; four(4) feet of gravel backfill; with a total depth of eleven(il) feet. The gravel should be placed between seven(7) and eleven(Il) feet. The existing seepage pit must be abandoned and caved in. Prior to the upgrade a permit must be issued from this department. If there are any further questions, please call this department at 264-4720. Sincerely, Robert C. Pratt, R.S. Associate Specialist RCP/ljw cc: Lomas and Nettleton 4449 Business Park Boulevard Grace M. Brown % Lee [1ouston & Associates 101 Benson Boulevard 99503 Josepk/Jane Filancia Post Office Box 1172. 99577 99503 1. Approval requested by: Mailing Address: 2. Property Owner: Mailing Address: GRFJ~TER ANCHORAGE AREA BOROUGH Department of Environmental Quality 3330 "C" Street, Anchorage, Alaska 99503 274-4561 Date Received )IR 6/28/74 Time of Inspection Date of Inspection 7/1/74 REQUEST FOR APPROVAL OF INDIVIDUAL SEWER & WATER FACILITIES FOR VA Smtlev's Real tv Don Zimmennan Phone: Phone: 694-g114 3. Legal Description: Lot 3~ Block 3, Eagle Park 4. Location: Melndy lane nfl Raven Ea~le River 5. Type of facility to be inspected R(n~le 6. Well Data: A. Type C. Construction Standard 7. Sewage Disposal System: A. Installed 1974 C. Septic Tank: 1. D. Seepage Pit: 1. E. Disposal Field: Total 8. Distances: A. Well to: Septic tank Nearest lot line B. Foundation to septic tank C. Absorption area to nearest lot line No. of bedrooms 4 B. Depth llO' D. Bacterial Analysis Satisfactory' B. Installer Wallace Construction Size 1~§0 Galls2. Manufacturer $~ack Steel Absorption Area ~' 2. Material Loq length of lines 118' , Absorption area 18' , Other contamination , Absorption area , Sewer Lines 35' EQ-034 (1/74) Page 1 of two pages Page 2 of two pages - Rec?est for Approval of Individual S..wer & Water Facilities Comments Approval Valid for one year from date.signed Greater Anchorage Area Borough, Department of Envlro~nental Quality DIAGRAM OF SYSTEM I certify that the information contained in this request for approval to be a true and accurate representation of the subject sewer and water facilities and these facilities are operating satisfactorily. SIGNED Date EQ-034 (1/74) I,~y 3, 1~7¢ Veterans Administration 429 b. Street Ancnora5e AK 95501 Lot 3, Block 3. Eagle Park Su~divtsion. ~ear Sir: lne subject lot is not available to puultc sc~cr, a:~d it ts rlot ~cono~ically feasible t~sarve tn~ lot wit~) puul.tc sewer at this tl~e. sewer system, if l~stall~d to local specifications, s~)odlc provida adequate sev, age disposal until suc~ tier4 as public sewer is ~vailable. l~,e water supply, wnt~) ~ust ~e an Individual drilled ~ell place~ at l~ast 100 feet fro~.~ t:~e steer syst~, sz~ould provide a potable supply of water if installe~ to state and local specifications. Sincerely, Jonn R. Leo, R.S. Eagle ~(ver ~istrict Sanitarian sr