Loading...
HomeMy WebLinkAboutWYNTER PARK #1 BLK 1 LT 20Pork Block Lot20 #051-491-33 Municipality of Anchorage Page Department of Health and Human Services Division of Environmental Sen4ces On-Site Sen4ces Section 825 'L' Sb'eet Room 502 P.O. Box 196650 A~chorage. AK 99519-6650 v, ww.cLanchorage.ak.us (907) 343-4744 ON-SITE WASTEWATER DISPOSAL SYSTEM AND/OR WELL INSPECTION REPORT Permit Number: SW010172 PID Number: 051-491-33 Name: Joseph P. and Connie G. Duran Wastewater System: New (~ Upgrade 2434~ Hearthstone Dr. Chugiak~ AK 99567 ABSORPTION FIELD 688-1236 Three (3) =O~T~.o~ ~S~o.T~ OM ~ LEOAL DESCRIPTION .8 ~' 3.S Ft. ! 20 Wynter Park No. 1 1 Ft. 2.5 2.5-3 Ft. 72 Well: [] New [] Upgrade c~.~: 5 Ft. "~'~'":'1 I°~'~'~":N/A A Ft. Ft.562.5 Fr' ASTM D3034 PVC Ft. MM&M Contracting 6/12-14/01 .,,.: ~ i.,,,~..~.,:Ft, ic.,~, ~,~.,~c.,,,~,:F, TANK SEPARATION DISTANCES I~ septic I-I Holding I-1 S.T.E.P. n Other. Tank Field Station Tank S~-,U~ Anchorage Tank 1,000 w. >200' >200' N/A N/A >25' Steel Two (2) s~,~w..>100' >100' N/A N/A V ~. LIFT STATION,~.~,~: - NONE ON LOT ~. >5' >10' N/A N/A c.,~o~.None Noted ~F,~.*,~,~ "'"'"": BENCH MARK Existing Septic Tank Pumped Crushed and Top o! Foundation Cleanout. Abandoned. Existing Absorption Trench Abandoned. 100.0 En~ir~eer's Inspections performed by: Mike Anderson Dates: 1". 6/la/01 ~~."~ 2"a 6/14/01 ~,'..,~lc~ ~. Department of Health and Human Services approval ¥."'~; CE-4381 .' Reviewed and approved by Date: ~ ',~/~" O/ -a~e~ ,,'.....'.'.,, ~'~,~ Munlclpalny Ot Anchorage I~age Z ot 3 DEPARTMENT OF HEALTH AND HUMAN SERVICES ENVIRONMENTAL SERVICES DIVISION P.O. Box 196650 - Anchorage, AK 99519-6650 - 343-4744 On-Site Wastewater Disposal System or Well Inspecti~.~..~. Permit Number SW010112 ~ ~~491-33 · PLAN AS-BUILT SCALE 1" = 3 A B S1 11.6 39.2 S2 18.2 42.9 C4 57.9 53.8 M1 57.8 53.8 C5 77.3 103.2 Municipality of Anchorage DEPARTMENT OF HEALTH AND HUMAN SERVICES ENVIRONMENTAL SERVICES DIVISION P.O. Box 196650 - Anchorage, AK 99519-6650 - 343-4744 On-Site Wastewater Disposal System or Well Inspection Report Page 3 of 3 Permit Number SW010172 PID No. 051-491-33 ,,- 98.§ 93.9 ~allo_n L\\\ It1~ ~ ~ep.. Ta~ 35' 90.0 Geotextile Fabric Drainfield ~ Rock 72' (Trench Length) 2" Insulation ~'* ~" 86.6 _ 76.0-+ PROFILE AS-BUILT 1" = 10' MUNICIPALITY OF ANCHORAGE Development Services Department On-Site Water & Wastewater Program 4700 South Bragaw Street P.O. Box 196650, Anchorage, AK g9519-6650 (go7) 343-7g04 ON-SITE WASTEWATER DISPOSAL SYSTEM PERMIT Upgrade Date Issued: Jun 07, 2001 Expiration Date: Jun 07, 2002 Permit Number: SW010172 : Legal Description: WYNTER PARK #1 BLK I LT 20 Design Engineer: 0014 Anderson Engineering Owner Name: JOSEPH P. & CONNIE G. DURAN Owner Address: 24344 HEARTHSTONE DRIVE CHUGIAK, AK 99567-6202 Parcel ID: 051-491-33 Site Address: 024344 HEARTHSTONE DR Lot Size: 23483 SQ. FT. Total Bedrooms: 3 Permit Bedrooms: 3 This permit is for the construction of: [] Disposal Field [] Septic Tank [] Holding Tank [] Privy [] Private Well [] Water Storage construction must be in accordance with: 1. The attached approved design. 2. ,NI requirements specified in Anchorage Municipal Code Chapters 15.55 and 15.65 and the State of Alaska Wastewater Disposal Regulations ( 18AAC72 ) and Drinking Water Regulations ( 18AAC80 ). 3. The engineer must notify DSD at least 2 hours prior to each inspection. Provide notification by calling (907) 343-7904 ( 24 hours ). ( Not required for a Water Supply Permit only ). 4. From October 15 to April 15, a subsurface soil absorption system under construction during freezing weather must be either: A. Open and closed on the same day. B. Covered, sealed, and heated to prevent freezing. / / Municipality of Anchorage Development Services Department Building Safety Division On-Site Water and Wastewater Program 4700 South Bregaw St. P.O. Box 196650 Anchorage, AK 99519-6650 www.ci.anchorage .ak.us (9O7) 343-79O4 ON-SITE SEWERJWELL PERMIT APPLICATION FOR a SINGLE FAMILY DWELLING Parcel I.D. 051-491.33 Permit Number SWO I O172. Property owner(s) MM&M Contracting Day phone 688-1236 Mailing address (1) P.O. Box 670495 Chuglak, AK 99567 ~ address (2) 24 Legal description (Lot, Block & Sub'd.) Lot 20, Block t~ W~nter Pa~ Subdivision No. 1 Legal description (Section. Township & Range) LotSize Z)~ 483 Acras~ Number of Bedrooms THIS APPLICATION IS FOR: Sewer Only Sewer and Well Sewer Upgrade THIS PROPERTY CONTAINS: Hot Tub Swimming Pool Therapy Pool Well Only Water Storage Jacuzzi Water Softening Unit I certify that the above information is Correct. I further cedify that this application is being made for a Single Family Dwelling and is in accordance with applicable Municipal Codes. (Signature of property owner or author[zed agent) Date of Payment: Receipt Number: (Rev. 12J00) Waiver Fees: Date of Payment: Receipt Number: ANDERSON ENGINEERING P:O: BOX' 240773 ANCHORAGE, AK 99524 522.7773 522-6779 (FAX) MEMORANDUM DATE: June 7, 2001 TO: FROM: Dan Roth ~ Mike Anderson, P.E. SUBJECT: Lot 20, Block 1, Wynter Park No. 1 Septic System Design and Permit Application We placed a third test hole on Lot 20, Block 1, Wynter Park Subdivision No. I on the slope above Test Hole No, 1 where the absorption trench is designed for placement. The hole was excavated to 10' and revealed similar soils to Test Hole No. 1. No groundwater was noted during excavation, but was found to be 8.2' below the surface the. following day: The water in Test Hole No. 1 was found at 6.5' below the surface which is slightly h~gher than previously measured. Based on these groundwater elevations we have redesigned the absorption trench for a total depth of 3.5', which is 4.7' above the current water table, The trench will be 72' long x 5' wide and have an effective depth of 2.5'. We are confident the system will be a minimum of 4' above the highest groundwater table in the area. Please review the revised data and, if acceptable, issue a permit to construct the absorption trench as revised. Thank you for your attention to this matter. May 2512001 Municipality of Anchorage Development Services Depadment 'On-Site Water and Wastewater Program 4700 South Bragaw Street Anchorage, AK 99519-6650 Subject: Lot 20, Block 1, Wynter Park Subdivision No. 1 Septic System Design and Permit Application Impacts to Adjacent Prop. edies Dear Onsite Services Engineer:. The owner of Lot 20, Block 1, Wynter Park Subdivision No. 1 intends to construct a new three-bedroom home on the lot. We are therefore applying for a permit to construct a new septic system on the lot to serve the proposed home. The attached Site Plan and backup documentation identify the location an,d, co..n.fig,uratio.,n of,the new.,septic s.y. stern. and the parameters used in the design. A!so ~aen[i~ea on me plans are tne ~oca~!.o.n oT the test hole and the alternate site. Existing drainage patterns are shown and w~ll not be altered by the development of the lot. We have surveyed the area and the new system will not confl, ict with other systems in the area. The subdivision is' currently served by a community water system. The lot is currently occupied by a mobile home. The mobile home will be removed from the lot and the existing septic tank and absorption trench will be abandoned in accordance with Municipal and State regulations. The septic tank will either be removed from the site or pumped, crushed and backfilled on site. The new septic system will then be constructed. Two test holes were recently placed on the lot to determine subsurface conditions. Soils were found to be fairly well graded sands and gravel with varying amounts of silt. Percolation tests in the material indicated rates approximating 1 minute per inch in the sand and 20 minutes per inch in the gravel. We are proposing a combined percolation rate of 12 minutes per inch with an application rate of .8. No groundwater was found during the excavation, but was noted at 7'and 6' below the surface in the test holes during the monitoring period. We are therefore DroDosina to place an absorption trench 72' lona x 5' wide with a 2.5' effective depth to treat the septic effluent. The distribution pipe {~'~1 be placed at 1' below the surface to provide as much separation as possible from the water table. The ground surface on the lot slopes as shown on the attached Site Plan with grades from west to east, which flatten in the area of the test holes. The new absorption trench will be constructed approximately 3' into the slope and parallel to the contours of the surface as much as possible in conformance with Municipal requirements. Grading 'Lot 20, Block 12, Wynter Park Subdivision No. 1 May 25, 2001 Page Two will be accomplished to assure surface drainage is away from the new trench. The existing drainage pattern on the lot will not be affected dudng development. If the system is constructed In accordance with our design the following statements apply: The system, if constructed as designed, will have no adverse impact on the wells in the area or those to be constructed in the future. o The system, if constructed as designed, will have no adverse impact on existing septic systems In the area or those to be constructed in the future. The system, if constructed as designed, will have no adverse impact on reserve space, either surface or subsurface, on any lots located in the area. The system, if constructed as designed, will have no adverse Impact on drainage patterns in the area. The current drainage pattern will be maintained. Sincerely, Michael E. Anderson, P.E. Attachments ?4 I I I 44 fi7 Community Water Water Water/' 45 22 '1 Community Water I$ 23 AREA MAP I0 II .s. CAL~ ~" = '~o0' C~mmunity Water / / PROJECT 15 14 49T~ /; 17 )6 CE NOTE: HEARTHSTONE DRIVE ;0 Gallon · · ~.ic Tank :. Three Bedroom -- - 25% ~louse' ~ .I BLOCK 1 WYNTER PARK NO. I - 72' Lona x 5' ~ Wide x ~½'Ef.f:TH2_ - Depth A~sorptlon Trenc .Abandon Existing Septic Tan~ and Absorption Trench in Accordance with ADEC Regulations. SITE PLAN SCALE 1" = 30' ANDERSON ENGINEERING P,O. Box 240773 ANCHORAGE, AK 99524 (9O7) 522-7773 Cell (907) 441-4000 SYSTEM LOT 20, BL0(~K 1, WYNTER PARK SUBDIVISION No. 1 DESIGN FACTORS: Three Bedroom Home Perc. Rate: 1 & 20 MinJInch' Application Rate: .8 GPDISF SYSTEM REQUIREMENTS: 5' Wide Trench System 1,000 Gallon Septic Tank 2.5' Drainfield Rock 3 Bedrooms X 150 GPD 1.8 GPDISF = 562.5 SF of Absorption Area 562.5 $FI5 LF (~Nidth)*.64 (Red. Factor} -- 72 LF Trench Length Therefore: Construct a 72' Long X 5' Wide X 2.5' Effective Depth Absorption Trench. Flowline Elevation in Trench to be 1' Below Original Ground Smface. Total Depth to be 3.5' Below Existing Ground. Mound Over Trench to Provide Minimum of 3' of Cover or Provide 2" of Direct Bury Insulation. .r s' "' I NOTE: TYPICAL WIDE TRENCH SECTION (NO SCALE) G~de Area Over Trench to D~in Away. Minimum 6' Se~tion From B~r~ Minimum 10' Secretion From Lot Line. =,n,=u= ro= roundw.te . Minimum 10' Secretion From Water Sewice Line. PERFORMED FOR: LEGAL DESCRIPTION: HUNICIPALITY OF ANCHORAGE DEPARTMENT OF HEALTH 8 HUMAN SERVICES 825 L STREET, ANCHORAGE, ~ 99502-0605 SOILS LOG - PERCOLATION TEST CONSTRUCTION-PAUL HYERS LOT 20, BLOCK 1, WINTER PARK SUBD. I 2 5 6 7 8 9 18 TEST HOLE # . OL / PT WELL 6RAD[D SANDS SW WELLCOHPACTEO SILTY SANDY-6RAVELS SLOPE 0% SITE PLAN WAS GROUNDWATER ENCOUNTERED? NO S L IF YES, WHAT DEPTH? 0 DEPTH OF WATER 7 ' P AFTER I~0NITORING: E DATE: 5/20/01 OX BOTTOH OF HOLE GROSS NET DEPTH OF NET READING DATE T~ME TIHE WATER DROP Start 5/13/01 10 25 12" 1 10:35 10 10' Recharge 10:36 12' 2 10~6 10 I0' Recharge 10;:? 12' 3 10.51 10 10' PERC RATE: 1 I'tlN./INCH PERC. HOLE DIAHETER: 6' TEST RUN BETWEEN ~1 5 FT. AND & ~ FT. COHHENTS: NO IMPI[RMEABLE$ ENCOUNTERE0 / TEST HOLE PRESOAKED PRIOR TO T(ST TEST PERFORHED BY: .T.L. KIHBROUGH I, MICHAEL E. ANDERSON, CERTIFY THAT THIS TEST WAS PERFOEHED IN ACCORDANCE WITH ALL STATE ./~ND J'*IUNIClPAL GUIDELINES ON THIS DATE: 2 § II-- 18 PERFORMED FOR: LEGAL DESCRIPTION: MUNICIPALITY OF ANCHORAGE DEPARTMENT OF HEALTH & HUMAN SERVICES 825 L STREET, ANCHORAGE, AK g9502-0605 SOILS LOG - PERCOLATION TEST CONSTRUCTION-PAUL MYERS LOT 20. BLOCK 1. WINTER PARK SUBD. TEST HOLE # 0t / PT POORLY GRADED SANDS SP WELLCOMPACTEO SILTY SANDY-GRAVELS GM SLOPE OX O~ SITE PLAN WAS GROUNDWATER ENCOUNTERED? NO S L IF YES, WHAT DEPTH? 0 DEPTH OF WATER 6 ' P AFTER MONITORING: E DATE: 5/20/O1 OX BOTTOM OF HOLE GROSS NET DEPTH OF NET READING DATE TIME TIME WATER DROP Start ~113101 10:30 12' 1 11.00 30 l.S' Recharge 11.01 12' 2 1131 30 1.5' Recharge I1;32 12' 3 1202 30 1.5" PERC RATE: ~D MIN./INCH PERC. HOLE DIAMETER: 6" TEST RUN BETWEEN 3 5 FT. AND tt ~ FT. COMMENTS: NO IMPERMEABLES ENCOUNTERED / TEST HOLE PRESOAKED PRIOR TO TEST TEST PERFORMED BY: T.L. KIMBROUGH I, MI(~HAEL E. ANDERSON, CERTIFY THAT THIS TEST WAS PERFORMED IN ACCORDANCE WITH ALL STATE JLND MUNICIPAL GUIDELINES ON THIS DATE: Municipality of Anchorage Department of Health & Human Services 825 L Street, Anchorage, AK 99502-0650 · SOILS LOG - PERCOLATION TEST Performed For:~ LegalDescfiption: Lot~O. Blockl. W_vnterPark Subdivision No.i SLOPE North 2 3 4 1 11 12 13 14 15 17 18 OG/OL SP GWIGM 21 South No' Was Groundwater Encountered? If Yes, What Depth? Bottom of Depth to Water Test Hole After Monitoring 8.2' Date: S L O P SITE PLAN See Site Plan 6/7101 E Reading Date Gross Net Depth To Net Time time Water Drop Perc. Rate: 1 Min./Inch Perc. Hole Diameter: Test Run Between Ft. and Ft. Comments: Same Material as Test Hole No. 1. Performed By: Mike Anderson. I, Mi~ Certify That This Test Was Performed In Accordance With All State and Municipal Guidelines In Effect On This Date: 6/7101 ON-SITE WASTEWATER DISPOSAL SYSTEM CONSTRUCTION AND MATERIAL SPECIFICATIONS SUBJECT: LOT 20, BLOCK 1, WYNTER PARK SUBDIVISION NO. 1 GENERAL: The scope of this project includes the abandonment of the existing septic tank and absorption trench in accordance with Municipal and State requirements. It also includes the procurement and placement of a new 1,000 gallon septic tank at the location shown on the site plan. Work also includes the construction of a new72 'long X 5' wide X2~-,effective depth absorption, trench at the location shown. The dis['ribution line in the trench w~ll be placed at 1' below the existing ground surface. Total depth of the trench will be 4' below the existing ground surface. A minimum of 2' of cover and 2" of insulation are required above the absorption trench to protect against frost penetration. All components of the septic system must be placed a minimum of 10' from all wells in the area. Construction shall be in accordance with the approved site plan, design drawings, Municipal Permit with any special provisions or conditions, and all applicable State and Municipal Wastewater Disposal Regulations. The Contractor shall be responsible for obtaining all underground utility locates and for the layout of the septic system and verification of the location of all lot lines. Unless .specifically agreed otherwise, the contractor shall be responstble for final grading areas subsequently depressed from soil settling. Property owner shall be responsible for revegetation of affected areas unless specifically agreed otherwise. Contractors installing wastewater disposal systems must be certified by the Municipal Department of Health and Human Services for system installations. Owners installing their own systems must receive prior approval from D.H.H.S. before beginning system installation. SEPTIC TANK INSTALLATION 1. A new 1,000 gallon septic tank must be be procured from an approved source and installed at the location shown. A septic tank is to be constructed by a certified septic tank manufacturer. Construction shall include two 4' cteanouts for pumping access. The septic tank shall be sufficiently bedded to prevent settling or shifting of the tank. All standpipes on the septic tank shall extend a minimum of 12 inches above final grade. Tanks installed without 4' of cover shall have a minimum of 2" of direct budal insulation. Lot 20, Block 1, Wynter Park Subdivision No. 1 May 25, 2001 Page 2 of 3 6. A foundation cleanout shall be installed one to four feet from the building foundation. Two cleanouts are required between the tank and the drainfield. 7. Final grading over the tank shall be such that a positive slope exists away from the septic tank. DRAINFIELD CONSTRUCTION: The drainfield shall be constructed to the dimensions shown on the design. The bottom of the trench shall be within 2" of level. Distribution piping must be placed level with perforations down atop a level bed of drainfield rock. Rock should then be placed over the pipe to provide a minimum of 2" of cover. A silt barrier or geotextile fabric must be placed between the drainfield rock and the natural soil backfill. 4. Monitor tubes must be 4" in diameter and installed at the locations shown on the design. The portion below ground must be perforated. Contractor shall verify the septic tank and drainfield are a minimum 100' away from any private water wells in the area, 150' from a Class "C" Well or 200' from any community well. Direct bury insulation must be placed over the distribution system if less than 3' of backfill depth is available. Finish grade over the trench must be mounded to prevent settlement or depressions. 7. Grade area surrounding the absorption trenches to drain away. A minimum 2' of accepting soil is required below the drainfield rock for a 5' wide trench. Contractor shall vedfy this condition pdor to placement of the rock. All pockets of unacceptable materials must be removed and replaced. MATERIAL SPECIFICATIONS: 1. Septic tanks must be constructed by a municipally approved septic tank manufacturer. 2. The following pipe materials are approved for use in septic system installations in the Municipality of Anchorage: Cast Iron (perforated and solid), ASTM D3034 or P.V.C. (perforated and solid), ASTM F810 or H.D.P.E. (perforated, but not solid) and ASTM D2662 or A.B.S. (perforated and solid). Insulation shall be at least 2" thick extruded direct burial polystyrene (Dow Chemical Co. Styrofoam HI or equal). Septic tank inlets and outlets shall be fitted with watertight couplings (Caulder, Femco, or equal). . Lot 20, Block 1, Wynter Park Subdivision No. 1 · May 25, 2001 Page 3 of 3 5. A permeable geotextile fabric (Typar, Mirafi or equal) must be installed between the final drain rock layer and the native soil layer. 6. Ail drain rock shall be .5" to 2.5" in diameter with less than 3% passing the #200 sieve. INSPECTIONS: Municipal Ordinance requires a minimum of two inspections. These inspections must be conducted under the supervision of a professional engineer registered in the State of Alaska. The first inspection must be conducted after the excavation of trenches, beds or pits and before the installation of any gravel. A septic tank may be set in place, but may not be backfilled. The second inspection must be conducted after the placement of the geotextile fabdc, gravel, distribution piping, standpipes, cleanouts and insulation. No backfill should be in place at the time of inspection. Contractor shall provide a copy of all field survey layout and construction notes for use in p'repanng the certified as-bu'It of the completed system. GREi ~" ANCHORAGF AREA BOF' 'H Department of Environmental Quality 3330 C Street Anchorage, Alaska 99503 NAME INSPECTION REPORT ON-SITE SEWAGE DISPOSAl. SYSTEM PHONE / / LOCATION SI-- PTIC TANK: DISTANCE FROM WELL INSIDE LENGTH MAN U FACTU R E R ,:ti'(/¢~,~ ~ _ INSIDE WIDTH ,-. NUMBER OF ~/~;' ~/; ~ { MATERIAL ~' ~;'d/~'~4' (~ COMPARTMENTS_ / LIQUID DEPTH __ _LIQUID CAPACITY./~(i:(i) GALLONS. SEEPAGE I~_1~ 7}?f;d4/I NUMBER OF PITS / . DIAMETER ~//z// OR WIDTH , LENGTH2 / , DEPTH LINING MATERIAL /,~¢~1(~ CRIB SIZE: ~IAMETER___DEPTH DISTANCE FROM: WELL TOTAL EFFECTIVE BUILDING FOUNDATION /~-/, NEAREST LOT LINE ABSORPTION AREA (WALL AREA) .SQ. FT. ADDITIONAL ABSORPTION WELL: TYPE ~(~''; J'lc/'/J/[/l] I ~ CONSTRUCTION DEP'FH BUILDING NEAREST NEAREST SEPTIC FOUNDATION__ LOT LINE ., SEWER LINE TANK CESSPOOL OTHER SOURCES APPROVED DISAPPROVED REMARKS DISTANCE FROM: SEEPAGE SYSTEM DISTANCES: INSTALLED BY: PIPE MATERIAL: _ t'('i/' ( ,.,;¢ ~/,1,,..,.~, ,..,. x LOT SLOPE: REMARKS: -g,?/¢~-, c DIAGRAM OF SYSTEM //£/,fz . l,) t /,/Vg DATE O Er E GEOTECHNICAL Er DEVELOPMEN'F CO. Box 90, Davis St,, Eagle River, Alaska 99577 694-2774 or 688-2280 Russell Oyster Ear/Ellis 694-2774 688-2280 Soils 8 Foundations Land Development SO._] L LOnG Performed for: Name:~>/-'~//~'FK ~Z:,~/~/~ ~¢sJ/J77/~l)l, No.,_ Mai'ltngAdd~ess: ~ ~ ,, ~Legal Description: ~LI~ I. ~T ~ , I~ ~1~ t~1~ L~'~.}~, 12 Ground Water Encountered: Yes_m- No ~ If yes, what depth Proposed Installation: Seepage Pit ~ Drain Field_~_ Comments :_~L/a ~,~z)Unl~ IH /~'i~- ~,~_ /~:D~-:I~ Perfomed by: , ~...' ... .~..: . :: . ,-.~~ : . ~,,- ~.. _ ..... ~: .~ ,'-.. ~'-' ~ . ...... .......... FOR A-S NGEE FAMILY DWELEING: .... .: .- , ;,, .'.. ~:., . .... ,.~ ~ ~., . ,. . : .... .. ... .... .' . J__~;~_ _~ ~-- . ~.....'.:'~:~. ~.' -. ~:-- ~.- ..-.E: ..:...''.'. :.'.{ ."':.' ....'.~':.:..:.'~~:.' · ; , '.~ ...~:'.' ~. 't ' ;' : ~ -" ' -' ' ."' '; - '. %""' .... ~~ . ' ,,. . -. · . ;,~. t '{'.'.~ .. .,...: .. ,..' .. ,, -- . ,, , ' , .... . . ..,.. ~ - - + ,.~;:. '." ".".'{'_{' E~n (s,e a~dress orzd.recbons), ,'24~ Hea,hstone Drive= -,-'..~_, .. :_ .~., ~' ~'~ · . :,;'" IEStat~Ag ' }'Day~p ~.:~ ? Rea ent~ ~ ' ' , '..' ..... ' ' .: : .. ; one ............... · .... · qu d,~?71~h'~db~DSDfo" k ........ -" '"-~' ". .... ;., '.-''-' ~, ~ '. Unless' ~he~ise m es~e e r p~c up.: :, · ,;, '; . . .,,, , '' ' :2. ~NU : -...Three ...... .. ." 3.' TYPE OF WATER sUPPLY: ' ~. ...... . hdvidua We · ' :, IndMdu~l Water, Sf0r.agel ,,r71 .. · '. ,Pul~lic Water System' ' ITl·. " TYPE OF. WASTEWATER DISPOSAl'..~.... ... ,,~,,v,,~,~ ,";'~:":'~':a',.,.-o,,r~;;-~:'e- ":' ..... :~:~F;R:.. _. .,..,. IndividUal Holdir{g tafi'~" - [] ~' ' .... Community On-si!e :_- , r~. ' ' Public Sew~r~ ,' The Municipality of Anchorage Development-Services Depadment (DSD) Issues Certificates of Health Authority Approval (HAA) based onty upon the representations given in paragraph.5 by an independent professional 'civil'- engineer' registered in the State of Alaska. Certificates of Health Authority Approval ere required for the t~ansfer of,' ' title (except between spouses) for properties served by a single family on-site wastewater dispdsal And/or wate~ supply systere. DSD also issues HAAs upon request to homeowners. Certificates of Health A~thority Apprpval ar~ · valid for 90 day~ from the date of issue for properties sewed by a private or Class C Well and r~ay' be reissued with new WateJ' sample results less than 30 days old. (Certificates may be reissued for a period of up to one year with ~alid water s;Jmples.) Certificates are valid for one year for propedies servc;d by Class A or B'w~lls'~r a'pt~blic water syste~. The Municipality of Anchorage is not responsible for errors or omissions in th~ 'professional engineer's work. , ,.,..,-,.,.,,,.,-.-,- ~ .. , .- .... ..,~ ...~ ........ .:,~ :,.,~, .? ~ .;. , . ,: ........ ,-.,, .- As ce~lied by my .s~..affixed herelo and as ~.th,e..v~al~at~on Oat,e, sh~ bel ..o~ !.v,e~lhat ~my~e~.~g~."~3l~,v ,, :_. ,,, · ...... based on procedures'oull ned n the Health 'Authonty Approval Gu~delines for th2s '-' ' '"on-s~te water supply and/or.wast _ew..~[~ disposal system I.s(are)sa[e,, funct.~nal ,a~nd a~,e~luate fo~lh~0um, ~,l~ei o[, · ........ ;.. ,; .', ' bedrooms and type Of st~u, ,cture nd~cated hereto. I furlh~.vedty that based on the.,nfo,-mation 0btaL ,n~l'fro~. the ..: . : ... ,:~,, · .... Muncpa tv of.Anch~:age ties'and fro/~,my nvestgabon'and msp~:t'h~n ,the on-site wat~' supp. ly~hd/~i'- · 3- '. · wastowater·d~sposal system ~s{are) in eomphance w~th~all '- Name of F~rm ,Anderson Engineenng ;'. ;~; ..... Address,PO,Box240773~Anchora,qe, AKg9524 ...................... ~..~ ,.. .... . .. · . .~n~ neers ,.~,,,,~ ~.,,,.,,.=, ........... , '.'. , . · .. ~sapprove~.- ..... . .. ;. ~. ' ' '. ' 'Conditona aDDrova for' z~.,.. '. ' AdditionalComments.' t' ':' ' ·" .' ' Attachments: HAA Checklist ' ' Septic System Advisory Well Flow Advisory Maintenance Agreements '- '. Supplemental Engineer's Repoi-t .... Other Original Certificate Date: Legal Description: A. WElL DATA Weti type A Total depth Municipality of Anchorage Development Services Department Building Safety Division On-Site Water & Wastewater Program 4700 South Bragaw St. P.O. Box 196650 Anchorage, AK 99519-6650 www,cLanchorage.ak.us (gOT) 343-7g0~ HEALTH AUTHORITY APPROVAL CHECKLIST Lot 20, Block 1, Wynter Parc Subcflvl$1on No, t Parcel ID: 05t.491-33 ifA, B, otC provide PWSID # Cased lo lt. FROM WELL LOG wen Log (Yin) W~es properly protected (Y/N) Casing heigM (above ground) AT INSPECTION Date of test Static water level Well production WATER SAMPLE RESULTS: Colite~ coinni~/100 nd. Date of sample: B. SEPTIC/HOLDING TANK DATA Tank Type/Matertal Sel~.~teel Tank size t,000 gal FoundaU~ deanout (Y/N) ! C. ABSORPTION FIELD DATA Total depth _6 It. Date of adequacy test g.p.m. g.p.m. Number of Compartments Depr,~___,~.i,:~ over tank (Y/N) Pumper New Coflmuction Date installed 6/13/2001 C~eanouts (Y/N) ¥ High water alarm (Y/N) 14 If yes, give date N/A ~ raflrq~ ~.p.dJft~ or ~/bdrm).BGPD/SF System type 5'WIdeShallowTmnch It. ~ 5 fi. Gravel belaw pipe 2.5 fl. Results (Pass/Fail) New Rx bedrooms New depth in. g.p.d. Fluid depth in absorption field before test in. Water added gal. Elapsed Time: min. Final fluid depth __ in. Absorption rate >= Any rejuvenation b'eatme~t (past 12 mo.) (Y/N & type) N UFT STATION Date installed Size in gallons 'Pump on' level at in. 'Pump off' level at __ in. Datum Cycles tested E. SEPARATION DISTANCES SEPARATION DISTANCES FROM WELL ON LOT TO: Septic tank/lift station on lot' N/A Absorption field on lot N/A Public sever main Sewer/septic se~ice line High water alarm level at Meels alarm & Circuit requirements?. On adjacent lots N/A On adjacent lots Public sewer manhole/deanout N/A Holding tank N/A SEPARATION DISTANCES FROM SEPTIC/HOLDING TANK ON LOT TO: Property line >5' Water se~tice line >10' Building foundation >5' Water main N/A Wells on adjacent lots >200' SEPARATION DISTANCE FROM ABSORPTION FIELD ON LOT TO: Absorption field >5' Sudace water >t00' Property line >10' Water Service line >10' Curtain drain None Noted Building foundation >10' Surface water >100' Water main >10' [xtveway, parkJng/veh~e storage. >25' Fo COMMENTS Wells on adjacent lots >200' ENGINEER'S CERTIFICATION I certify that I have determined through field inspect~ns and review of Municipal records that the above systems are in conformance with MOA HAA guidelines in effect on this date. Engineer's Printed Name Michael E, Anderson, P.E. Date 7/1M)t in. *'L~':.' A .~'L~,~ ,,,,, C~. '-~?' '"'Z ...' :- Wab~ F~ $ Date ~ ~t ~ipt Num~ MUNICIPALITY OF ANCHORAGE DEPARTMENT OF HEALTH & HUMAN SERVICES DIVISION OF ENVIRONMENTAL SERVICr"S CERTIFICATE OF INSPECTION FOR HEALTH AUTHORITY APPROVAL OF ON-SITE SEWER AND WATER FACILITY Application Da!e .. GENERAL INFORMATION (MUST RE COMPLETED PRIOR TO SUBMITTAL) (a) Legal Description (include lot, block, subdivision, section, township, range) / Location (address or directions) (b) Property OwnerJ~/.f~//~/,'//"¢' -- ~.lephone: Home Address/~'~''' ~/'-~¢/~'~ -7~ ~' ~/~Z. % Mailing (c) Lending Institution~ ' ~) ~ ~ ~ ~ Mailing Address ~ · (d) Real Estate Company and Agent Address /~O~¢ ~/~. ~ ~ Telephone Telephone Business (e) Mail the HAA to the followino address: or: Check here, Z~ if hold for pick up. List contact person and day phone number below. S &-5-ENGINEER.lNG 17034 Eagle Rlxe~ Loop Road No, 204 ¢? d~' ¢ ~ ~ ¢ ~ ~,- Eagle Rlver~ Alaska 99577 2. TYPE OF RESIDENCE Single-Family/.~ Number of Bedrooms WATER SUPPLY Individual Well [] Community F] PublicA Note: If community well system, must have written confirmation from the State Department of Environmental Conservation attesting to the legality and status. SI=WAGE DISPOSAL OnsiteM Public [] Community [] Holding Tank Note: If corn m unity well system, must have written confirmation from the State Department of Environmental Conservation attesting to the legality and status. Page 1 of 2 72 025 fray 8/86) Fronl ENGINEERING FIRM PROVIDING INSPECTIONS, TESTS, FILE SEARCH, DATA AND INFORMATION As certified by my seal affixed hereto and as of the validation date shown below, I verify that my Juvestigation of this Health Authority Approval shows that the on-site water supply and/or wastewater disposal system is sate, functional and adequate for the number of bedrooms and type of structure indicated herein. I further verify that based on the inlormation obtained from the Municipality of Anchorage files and h'om my investigation and inspection, the on-site water supply and/or wastewater disposal system is in compliance with all Municipal and State codes, ordinances, and regulations in effect on the date of this inspection. Name of Firm S & $ ENGINEERING ~E~gl~-Rl~r~.oop Road [~... ~,. Address Date Telephone ,-~ ~'//-Z ¢-.~¢' Approved for .7~.~.,.t/.,¢ (3~ bedrooms by Dale Approved __/~/'~ Disapproved Conditional Terms of Conditional Approval CAUTION The Municipality of Anchorage Depadment of Health and Human Services (DHHS) issues Flealth Authority Approval certificates based only upon the representations given in paragraph 5 above by an independent professional engineer registered in tile State of Alaska. The DHHS does this as a courtesy to purchasers of homes and their leading institutions in order to satisfy certain federal and state requirements. Employees of DHHS do not conduct inspections or' analyze data before a certificate is issued. The Municipality of Anchorage is not responsible for errors or omissions in the professional engineer's work. Page 2 of 2 72 025 IRev 8/86) Back MUNICIPALITY OF ANCHORAGE (MOAi MUNICJPALI'~Y OF ANCHORAGE Div~k~.TH,._._.. AUTHORITY APPBOVAL (NAA) ENVIRONMENTAL SERVICES CHECKLIST - FEBRUARY 1984 264-4720 MAY 7 1987 Legal Description: --/-(~)'7-' ~,,oq ~//~ RECEIVED WELL DATA Well Classification _ / / - Well Log Present (Y/N) Total Depth Cased to Static Water Level Casing Height Above Ground Electrical Wiring in Conduit (Y/N) Separation Distances from Well: TO Septic/Holding Tank on Lot To Nearest Edge of Absorption Field on Lot ~-(-~)~ To Nearest Public Sewer L ne Cleanout/Manhole Water Sample Collected Dy Water Sample Test B~9~.ults Cornments~ ,.r V',,J .~- If A. B, C D.E.C. Approved Date Completed Yield Depth of Grouting Pure a Set At Sanitary Seal on Casing (Y/N) Depression Around Wellhead (Y/N) · On Adlo~nmg LOtS r"/" _; On Adjoining Lots To Nearest Public Sewer To Nearest Sewer Service Line on LOt . Date B. SEPTIC/I-fOLDING'rANK DATA Date Installed ~"/'~//'~'~-- Size //zCg/~)C~ No. of Compartments Standpipes (~) _ Air-tight Cap (~N) __ Foundation Clear ::)ut (Y,(~)~ Depression over Tank(Y~ Date Last Pumped ~:--~"/4 7~r~'¢/7 Pumping/Maintenance Contract on File (Y/N) ,/~dr,.//9 ; for Holding Tank High-Water Alarm (Y/N) /,J Separation Distances from Septic/~ Tank: To Water-Supply Wel ~_~ r_¢ To Property Line ,.~C'~ To Water Main/Service Line Cours/~ Comments ~;2~¢'~//¢' ~¢/~' ~ ~' 6/ / Temporary Holding Tank Permit (Y/N) /~J To Building :oundation _ To DJsoosal Field To Stream Pond, Lake. or Major Drainage Page 1 of 2 C, ABSORPTION FIELD DATA Soils Rating in Absorption Strata Date Installed Width of Field Type of System Design Length of Field ~/0 Depth of Field //C~) Gravel Bed Thickness ~7 Square Feet of Absorption Area F7 ~ ~ ~ Standpipes Presen (~,!) Depression over Field ( Date of Last Adequacy Test Results of Last Adequacy Test d / ~2 ~ / ~ Separation Distance from Absorption Field; To Water-Supply Well ~ 4¢ o To Propedy Line ~O To Building Foundation /~ ~ ~P~ To Existing or Abandoned System on Lot ~u~ D ~ ; On Adjoining Lots ~ To Water Main/Service Line /¢ (~- To Cutbank (if present) ~o ~-~ To Stream/Pond/Lake/or Major Drainage Course ~ O ~' ~ TO Driveway, Parking Area, or Vehicle S~age Area ~ Comments ~/~ //~¢~ D, LIFT STATION Date Installed Dimensions Size in Gallons "Pump On" Level at High Water Alarm Level at Tested for Manhole/Access (Y/N) "Pum~ Off" Level / Pumping Cycles during Adequacy Test. Meets MOA Electrical Codes (Y/N) Comments ** Check Permitted Bedroom Rating Against HAA Request ** I certify that I have checked, verified, or conformed to all MOA and HAA guidelines in effect on the date of this inspection. Signed S~ENGi NEEEiN G Date Compar~70~4~E~aa_le R~ L~ Road Receipt No. Date of Payment Amount: $ Page 2 of 2 72-026 (11/84) Telel~hone: (907) Address' ANCHORAGE/WESTERN OISTRICT OFF ICE 4137 "E" STREE[, SUITE 303 ANCHORAGE, ALASKA q9501 274-2533 [)ATE: A]):i i i ,_ 1.87 PWS ~.B.~} 21 t 431 To Whom it May Concern: According to records on file in this of'lice the ~4ater System is in co,npliance wii:h the State Drinking l,/ater Regulations Sincerely,