HomeMy WebLinkAboutVOYLES BLK 1 LT 3Bis Qin f �=3 Municipality of Anchorage Development Services Depadment Building Safe~ Division On-Site ~ter and Wastewater Program, 4700 S. B~gaw St. P.O. Box 196650 Anchorage, AK 99519-6650 Page of ~.ci.anchorage.ak.us (907) 343-7904 ON-SITE WASTEWATER DISPOSAL SYSTEM AND/OR WELL INSPECTION REPORT Permit Number: S~00013~ PID Number: 05]-0~4-~ Name: ~Oh, & Delores ~ra~ill Wastewater System: ~ New ~ Upgrade Address: 23532 Chandelle Drive, Chugiak, AK 99567 ABSORPTION FIELD Phone: Number of Bedro~s: ~ ~ Deep Trenoh ~ 8hallowTrench ~ Bed ~ Mound ~ ~her: LEGAL DESGRI PTION ~, ~,tm: 0.45 ~pv~t~ 10 It. Block: Lot: ~u~ivision: Depth to pipe bo~om from original 9rode: Gravel depth ~neath pipe: 1 3B Voyles 2.99 ~t. 7.01 ~t. To. ship: Range: ~ion: Fill added above original grade: Gravel Length: 0.34 - 2.4 Ft. 72 Ft. Well: ~ New ~ Upgrade or~at,: ~bo~o*~i~,: l Di,t,,~,b,~,~i,o~: 2.5 Ft. 1I " Ft. Cla~sific~ion (Private, A, ~, C): To~l Depth: Cased to: Total abmrption ama: Pipe Material: P~vate- Existing 2~t Ft. Ft 1~9 F? D3034 Driller: D~e Drilled: ~atic W~er L~el: Installer: ~ Date InstallS: Ft. Unknown - See Letter 6/15/2000 Yield: GPM Pump Setat: Casing HeightAb~e Ground: 2 21 .t. 1 ~. TANK 8EPA~TION DISlANCE$ ~ Septic ~ Holding ~ S.T.E.P. ~ Other: T~ To Septic Ab~rption Lift HolOin~ ~u~/Private Manu~urer: Capa*~: .rom Tank Field Station Tank S~er Line Premier Plastics 1~0 Well 100~ 100~+ 100~+ NA 2~+ Material: Number of Compa~ents: HDPE s~..~t~r ~00'+ ~00'+ ~00'+ NA ~ / LIFT SlAIION Lot Line ~+ 10~+ ~+ NA~ size: Manu~urer: "" GaL Foundation ~+ 10~+ ~+ NA "pump off' lewl ~: "Pump ~' level at in. High ~ter alarm at: in. in. Cumin Drain NA ~ ~0~+ NA NA Pump Make & Model Ele~rical Inape~i~s performed by: Remarks: * None known. See attached documentation letter. BENCH MARK Location and De~ription: 5~ ~~O ~A~~/~/~ ~ t~,~~ DoorSill Assumed Elevation: Engineer's Stamp Inspections performed by: S&S (1" & 2"a) ArcTerra (3~) Dates: 1sT & 2~ ~/15/20~ 3~D 03/23/20~ Developmen e ice ep .mentApproval AS-BUILT SYSTEM DETAILS / SITE PLAN Permit: SW0001.32 VOYLES S/D BLOCK 1, LOT 3B PID: 051-064--76 -- (.__) B-C=30' 3-3=63' A-E=41.5' ~ , ,~,, B-r=4S~ ~ I I -- O~ ~'~ SCALE: NTS ~ ...... ~...~. PREPARED FOR: ~ ~ ~ CHUGIAK, AK 99567 ". .~.D*RY: ~R*~: BMW ~ , , . ~~~ o~. ~m ~,~: NWl 460 *c~ Rm: 11017.dwg ~oe No.: 11--017 < AK. 99577 CONSULTING~ INC 212 E. 51st Ave, Anchorage, AK. 99503 Office (907) 868-3791, Fax (907) 868-3793 March 28, 2011 Municipality of Anchorage Development Services Department On-Site Water & Wastewater Program P.O. Box 196650 Anchorage, AK 99519-6650 Subject: Undocumented System - Voyles Block 1, Lot 3B Per your instructions, we have investigated the subject property's undocumented system and it appears as if it was constructed per the 2000 S&S Engineering design and Municipality of Anchorage permit #SW000132. The owners and record engineer are deceased and every attempt was taken to gather any available information on the on-site systems. Field measurements were taken and locatable standpipes noted. The standpipes were at or below grade. One of the post-tank cleanouts and the foundation cleanout were not found, but we assume they are under grade. However, there is a foundation cleanout in the basement. Please see attached photos. No well log could be found. The well had recent work done on it in December 2010 (a new pitless and well pump was installed); please see attached Pump Log from Jim Sullivan. Total depth was verified to 231' and no perforations in the top 40' noted. If you have any questions, please contact me at 868-3792/FAX 868-3793. Respectfully submitted, ArcTerra Consulting, Inc. Attachments: Wastewater Absorption System Inspection Report w/Photos COSA Documents SGS Water Analysis As-Built Survey 20441 PTARMIGAN BLVD · EAGLE RIVER, AK 99577-8736 · PH (907) 868-3791 ° FAX (907) 868-3793 CONSULTING~ INC 212 E. 51st Ave, Anchorage, AK. 99503 Office (907) 868-3791, Fax (907) 868-3793 April 5, 2011 Municipality of Anchorage Development Services Department On-Site Water & Wastewater Program P.O. Box 196650 Anchorage, AK 99519-6650 Subject: Septic Driveway Waiver - Voyles Block 1, Lot 3B Per your inspection report comments regarding the existing septic system for the subject lot, we respectfully request that a waiver be granted for the approximately 14.5' portion of the leachfield that exists in the airplane hanger's driveway. This septic system has operated without any known issues for over 10 years. The portion in the driveway does have insulation over the end of the field, is assumed will not be normally used during winter months and will have snow cover and a cast iron riser cover in the driveway to protect the field from potential freeze and damage to the end cleanout. Also, the majority of the field cover is fairly deep (3.33' - 5.27'). The total length of the drainfield is 77' long--5' longer than required for the 3- bedroom residence. In the recent adequacy test, the system absorbed 643 gallons in one day or 8.35 gallons per lateral foot. Discounting that 14.5' portion in the drive, the remaining 62.5' of trench would absorb 522 gallons per day--which is more than required for the 3-bedroom residence. The system is in plain view in the lawn and any possible overflow would be easily visible. We do not expect there to be any adverse effect on this system or adjacent lots by the existence of a portion of the leachfield in the driveway and respectfully request the waiver be granted. If you have any questions, please contact me at 868-3792 / FAX 868-3793. Respectfully submitted, ArcTerra Consulting, Inc. Kenneth M. Duffus, P.E. 'e MunicipaliW '°f Anch°ragc Buihllng Safety Divlston P.O. lh~x l{XiCf-,O · 4700 S. Bragaw Strcct Anchorage, Alaslm !Y.)519-6C~0 · (907) 6/7/2001 htll~:/Yww,,v.cl.m~chorug¢.ak.us John & Delores Graybill 3712 Barbara Dr. Anchorage AK Stlbject: Expired On-Site Water and/or Wastewater Permit. Permit Number: SW000132, Parcel ID://051-064-76 Dear John & Delores Graybilh An On-Site Water/Wastewater Permit, number SW000132, issued by this office for a single-family system, expired on May 30, 2001. This permit was valid for 365 calendar days. If this was a well permit and the well has been drilled, a well log must be sent to this office for documentation of the installation and to close the permit. If this permit was for a wastewater disposal system, an original as-built inspection report must be sent to this office for review, approval and documentation. This as-built inspection report must be signed by the licensed Professional Engineer who inspected the installation of the system. As-built inspection reports are required to be submitted within 30 days of the completion of the system. If no system was installed under this permit, and you are still planning to install a well or wastewater disposal system, a new permit must be obtained from this office. When applying for a new permit, the fees are: $320.00 for a wastewater permit and $120.00 foi' a well permit. If you have any questions, please call this office at 343-7904. Sincerely, {Letters Sent 6/7/01 without copies being made, second printing for file copies}' James Cross, PE Manager On-Site Water and Wastewater Program eno: Copy of permit MUNICIPALITY OF ANCHORAGE Department of Health end Human Services On-Site Services Program 825 L Street, Room 502 P.O. Box 196650. A~chorege, ,AK 99519-6650 (907) 343-4744 ON-SITE WASTEWATER DISPOSAL SYSTEM PERMIT Upgrade Date Issued: May 30, 2000 Expiration Date: May 30, 2001 Permit Number: SW000t32 Legal Description: VOYLES BLK I LT 3B Design Engineer:. 0003 S & S Engineering Owner Name: John & Delores Graybill Owner Address: 3712 Barbara Dr. Anchorage, AK 99503- Parcel ID: 051-064-76 Site Address: 023532 CHANDELLE DR Lot Size: 62760 SQ. FT. Total Bedrooms: 3 Permit Bedrooms: 4 This permit Is for the construction of: [] Disposal Field [] Septic Tank [] Holding Tank [] Pdvy [] Pdvate Well [] Water Storage All construction must be In accordance with: 1. The attached approved design. 2. All requirements specified In Anchorage Municipal Code Chapters 15.55 and 15.65 and the State of Alaska Wastewater Disposal Regulations ( 18AAC72 ) and Drinking Water Regulations ( 18AAC80 ). 3. The engineer must notify DHHS at least 2 hours pdor to each inspection. Provide notification by calling (907) 343-4744 ( 24 hours ). ( Not required for a Water Supply Permit only ). 4. From October 15 to April 15, a subsurface soil absorption system under construction during freezing weather must be either:. A. Open and closed on the same day. B. Covered, sealed, and heated to prevent freezing. Received By: Issued By: ~ Date: "~- ~ d - ge. Date:. ,~' ~ 'O - OO ROBERT C. COWAN, P.E. May 23, 2000 CIVIL ENGINEER~ (907) 694-2979 FAX (907) 694-1211 MUNICIPALITY OF ANCHORAGE Depa~hnent of Health and Human Sen, ices P.O. Box 196650 Anchorage, AK, 99519 REFERENCE: Lot 3A, Block 1, Voyles S/D It is requested that you issue a permit to install a septic system to serve the three bedroom dwelling on the referenced property. A test hole was excavated and a percolation test was performed. The approximate location of the test hole is located on the attached site plan. At the time of excavation on 5/13/00 water was not found. Depth to water after seven days of monitoring was 15.5 feet, believed to be from heavy rain prior to monitoring. We do not anticipate any adverse effects on neighboring wells, septic systems, reserve areas or drainage patterns by the installation of the proposed septic system. The construction of this system will not prevent any future development on any of the adjacent properties. If you require additional information, please contact us. Sincerely, Robert C. ¢ow~,,, P.E. R.C c ljhm Enclosure 17034 NORTH EAGLE RIVER LOOP · SUffE 204 · EAGLE RIVER, ALASKA 99577 J.H.I,,,I. R.C.C. 5-25-2000 1 OF' 2 DESIGN CRITERIA: s~.uc~uRcs. [.~l.~N]'$o O" JiNCROA~HMJ[NT~J ,, '~ ol SOl~ = 450 GPD/SQ.~. ~ ~-eu~ct s~ O~WN ~: WlLL~ D. FLE~ING 450/0.45 = 1,000 SQ.~. REQ'D. ~ ~ mE R~ON~a~W ~ mE TRENCH CRITERIA: ~s~c~s. ~ .~.~.. ~s ..~ 17o~ ~ R~ L~ ~ 10' DEEP c~s~. ~ ~R. ~ ~S77 7' EFFECTIVE PHONEI (907)6~4-29~i 2.5' WIDE r~! 0o7)69~-~ 72' LONG I ~11 P~T~ ~STI J w~T~ L~SS T~ ,' ~,r / / / J ~4 n~ring [~ LOT 3A, BLOCK 1, J.H.M. ! R.C.C. DESIGN CRITERIA: 3 BDRM -- 450 OPD so~s = 4so CPD/S~.rr. ~so/o.4s - ~.ooo s~.~r. ~Eq'D. TRENCH CRITERIA: 10' DEEP 7' EFFECTI~ 2.5' WIDE 72' LONG VOYLES SUBDIVISION 5-25-2000 2 OF WILLIAM D. FLEMING 100' ~VELL R.~)IUS REQUIRED TO LOCATES EXC&VATION ! I ALL PORTIONS OF SYSTEM WITH LESS THAN 3.5' OF' COVER REOUIRE INSULATION. LOCATE FCO OR INSTALL NEW INSTALL NEW __ 1000 GALLON POLYETHYLENE SEPTIC INSTALL~ NEW~ LEACHFIELD EXISTING TRENCH & 1000 (TO BE & Municlpalily o! Anchorage DEPARTMENT OF HEALTtl & HUMAN SERVICES 825 "L" Street. Anchorage. Alaska 99502-0650 SOILS LOG -- PERCOLATION TEST PERFORMED FOR: LEGAL DESCm"T,ON: I 2 3 § 6 9 12- 13- 1G 20- COMMENIS ._~.~ ~'~'~- / ~... '.: .. ',~' ~ Township. Range. Section: SLOPE SITE PLAN WAS GROUND WATER ENCOUNTERED? Time Time Wale~ Df Dp PERCOLATION RAIE a~'/O (mmuleS/mch) PERC IIOLE DIAMETER tEST RUN BETWEEN ~"-...~F 1' AND : -- -- I ~ CERIlFY tHAt 1H~S teST WAS PERFORMED IN PEnFOflMED eY $ & S ENGINEERING 17034 Eagle River Leap Read No. 204 .... . ~/.,. / QGREA! ' ANCHORAGE AREA BORO, Department of Environmental Quality 3330 C Street Anchorage, Alaska 99503 INSPECTION REPORT ON-SITE SEWAGE DISPOSAL SYSTEM LOCATION SEPTIC TANK: ~ -' ,//~O-~/~,.(~ /~/~'. PHONE MAILING ADDRESS NUMBER OF MATERIAL LIQUID DEPTH .LIQUID CAPACITY J~'(~-~) GALLONS. DISTANCE FROM WELL INSIDE LENGTH INSIDE WIDTH SEEPAGE NUMBER OF Pits LINING MATERIAL BUILDING FOUNDATION__ ADDITIONAL ABSORPTION DIAMETER I ZO OR WIDTH CRIB SIZE: DIAMETER NEAREST LOT LINE LENGTH ~,DEPTH F! DEPTH ~-/ DISTANCE FROM: WELL TOTAL EFFECTIVE ABSORPTION AREA (WALL AREA) ~¢~'] .SQ. FT. WELL: '~-0 TYPE BUILDING FOUNDATION CESSPOOL APPROVED CONSTRUCTION NEAREST LOT LINE OTHER SOURCES DISAPPROVED NEAREST SEWER LINE DEPTH DISTANCE FROM: SEPTIC SEEPAGE TANK SYSTEM REMARKS DISTANCES: INSTALLED BY: PIPE MATERIAL: LOT SLOPE: REMARKS: Form NO. EQ-031 DIAGRAM OF SYSTEM DATE GREATER ANCHORAGE ArEA BOROUGH DEPARTMENT OF ENVIRONMENTAL QUALITY 3330 "C" STREET ANCHORAGE~ ALASKA 99503 SEWAGE DISPOSAL SYSTEM -- APPLICATION AND PERMIT PERMIT NO. NAME OF APPLICANT '-~/~//'/~/ INSTALLATION LOCATION _/C LEGAL DESCRIPTION J"'~) ½'~: INSTALLATION OF: SEPTIC TANK SEEPAGE PIT . DRAIN FIELD FINANCED THROUGH TO be INSTALLED OTHER __ NOTEI THIS PERMIT IS ROT VALID WITHOUT SOIL TES~' FINAL INSPECTION: 24 HOUR NOTICE REQUIRED. BACKFILLING OF ANY SYSTEM WITHOUT FINAL INSPECTION BY THE DEPARTMENT OF ENVIRONMENTAL QUALITY AUTHORITY WILL BE SUBJECT TO PROSECUTION. SEPTIC TANK SIZE //~-'~,~'~ ,_~'/c-£ -:':/' /~" TYPE /':/'~'"~/z?~//3~-~- SEEPAGE AREA SIZE FOUNDATION TO SEPTIC TANK FOUNDATION TO SEEPAGE PIT , DRAIN FIELD SEPTIC TANK TO seePAGE PIT WALL WELL TO SEPTIC TANK /~J ~ / SEEPAGE Pit SEPTIC TANK, ~//~/~ SEEPAGE Pit .~ , DRAIN FIELD SEEPAGE PIT . , DRAIN FIELD CAST IRON INTO AND OUT OF SEPTIC TANK AND INTO CRIB CROSSING GAP OF EXCAVATION 5 FEET INTO UNDISTURBED SOIL. 4 iNCH DIAMETER CAST IRON SIPHON PIPES ON SEPT[C: TANK AND SEEPAGE Pit FITTED WITH AIRTight REMOVABLE CAPS. GRAVEL BACKFILL CONFORM TO BOROUGH REGULATIONS REGARDING INSTALLATION. LICENSED DESIGNER [ CERTIFY THAT I AM FAMILIAR WITH THE REQUIREMENTS OF GREATER ANCHORAGE AREA BOROUGH ORDINANCE NO. 28-68 AND THAT THE ABOVE O8-EGEOTECHNICAL ~ DEVELOPMENT CO. Box 90, Davis St., Eagle River, Alaska 99577 694-2774 or 688-2280 Russell Oyster Earl Ellis 694-2774 688-2280 Soils 8 Foundations Land Development SOIL LOG Perfomed for: Name: ',~-~/Y~/ C'~£JF~/LC Tel. No, Mailing Address: .~1/~ ~/~///Z/) /~..~;~,., 'Legal Descrtption:k~pY~-£ 5~.~. ~'~/~ JEd. ~/~J.K/,Y4. JE¢. De~th (feet}. Soil Charactert~Mc~ 4 lO Ground Water Encountered: Yes_____No~ If yes, what depth__~ Proposed Installation: Seepage Pit ~ Drain Field~ Performed by: 0SE 694-2774 Soils 8 Foundations GEQTECHNICAL. 8- DEVF.'.OPMENT Box 90, Davis St, Eagte River, Alaska 99577 694 2774 or 688-2280 SOIL LOG CO, Earl 688-2280 Land Development Performed for: Name: Mr. John L. Graybi]l ,~____~__Tel, NO. 688-9116 Mailing Address: P. o. Box 358 C~hu_y~iak, Alaska 99567 Legal Description:, Lot 4, Block i, Voiles Subdivision ~ Soil Characteristic o -- ML - Silt topsoil ~th roots and organics. 275 sqo ft./BE° 2 GM - Silty Sar~y Gravel with cobbles to 8 inches. 270 slq. fto/Br. 8 i0__ 12 - 13 14 Percolation Rate = 37 minutes/inch = 270 sq. ft./BRo Water seeping into pit readily at 10 feet. Ground Water Encountered; Yes xX No If yes, what depth Proposed Installation: Seepage Pit Drain Field~_~ Comments: Pit measured a~proximately 3 x 15 feet in plan area. All sides of pit__ !off. ed the same. Performed by: Date:~25, 1977 S 44 J1 -L qg'/7 Municipality of Anchorage Development Services Department Building Safety Division On-Site Water and Wastewater Program 4700 Bragaw Street P.O. Box 196650 Anchorage, AK 99519-6650 www.muni.org/onsite (907) 343-7904 CERTIFICATE OF ON-SITE SYSTEMS APPROVAL FOR A SINGLE FAMILY DVVELLING Parcel I.D. 011-121-53 1. GENERAL INFORMATION Complete legal description COSA# Date: Expiration VOYLES BLOCK 1, LOT 3B Location (site address) 23532 CHANDELLE DRIVE, CHUGIAK, AK 99567 Current Property owner(s) JOHN & DELORES GRAYBILL Day phone Mailing address 8650 CUSTER SCHOOL ROAD, CUSTER, WA 98240 Lending agency Day phone Mailing address Real Estate Agent LES BAILEY & ASSOC. Day phone Mailing Address Unless otherwise requested, COSA will be held by DSD for pickup. 2. NUMBEROF BEDROOMS: 3 TYPE OF WATER SUPPLYi Individual Well Individual Water Storage Community Class __ Well Public Water System TYPE OF WASTEWATER DISPOSAL: [] Individual On-site [~ [] Individual Holding Tank [] [] ~ Community On-site r'-] [] Public Sewer r-'] The Municipality of Anchorage Development Services Department (DSD) issues Certificates of On-Site Systems Approval (COSA) based only upon the representations given in paragraph 4 by an independent professional civil engineer registered in the State of Alaska. Certificates of On-Site Systems Approval are required for the transfer of title (except between spouses) for properties served by a single-family on-site wastewater disposal and/or water supply system. DSD also issues COSAs upon request to homeowners. Certificates of On-Site Systems Approval are valid for 90 days from the date of issue for properties served by a private or Class C well and may be reissued with new water sample results. (Certificates may be reissued for a period of up to one year with valid water samples.) Certificates are valid for one year for properties served by Class A or B wells or a public water system. The Municipality of Anchorage is not responsible for errors or omissions in the professional engineer's work. 4. STATEMENT OF INSPECTION BY ENGINEER As certified by my seal affixed hereto and as of the validation date shown below, I vedfy that my investigation, based on procedures outlined in the Certificate of On-Site Systems Approval Guidelines for this application, shows that the on-site water supply and/or wastewater disposal system is (are) safe, functional and adequate for the number of bedrooms and type of structure indicated herein. I further verify that based on the information obtained from the Municipality of Anchorage files and from my investigation and inspection, the on-site water supply and/or wastewater disposal system is(are) in compliance with all applicable Municipal and State codes, ordinances, and regulations in effect at the time of installation. Name of Firm ARCTERRA CONSULTING, INC. Phone 868-3792 Address 20441 PTARMIGAN BLVD., EAGLE RIVER, AK 99577 Engineer's Printed Name KENNETH M. DUFFUS Date 03/28/2011 Engineer's Comments: This investigation was completed in compliance with ADEC and MOA regulations. The assessment of the condition of the well and septic applies only to the conditions as of the day tested. The fiow and absorption rates may change due to subsurface conditions that may not be observed from the surface, changes inland use, local soil characteristics, groundwater levels that may fluctuate during the year and the water usage of the family being served by the system. The operational life of all well and septic systems are subject to these various and dynamic characteristics and are outside the control of the evaluator of the well and septic system. Therefore, ArcTerra can not give any estimate of how long a system will function satisfactory for current or future occupants or can ArcTerra guarantee that no unseen encroachments, deficiencies or discrepancies exist. DSD SIGNATURE t~" Approved for -~ Disapproved. Conditional approval for bedrooms. bedrooms, with the following stipulat, ions: Attachments: COSA Checklist Septic System Advisory Well Flow Advisory Nitr~2t~e Advisory X Arsenic Advisory Maintenance Agreements Supplemental Engineer's Report Other Original Certificate Date: Municipality of Anchorage Development Services Department Building Safety Division On-Site VVater & Wastewater Program 4700 Bragaw Street P.O. Box 196650 Anchorage, AK 99519-6650 www.muni.org/onsite (907) 343-7904 CERTIFICATE OF ON-SITE SYSTEMS APPROVAL CHECKLIST Legal DescriPtion: VOYLES BLOC/( 1_~ LOT 3B A. WELL DATA Well type PRtYA~ If A, B, or C provide PWSID # Date COmpleted APprox. 1975 sanitary seal (Y/N) X Total depth 221+ f. Cased to 40+ ff. FROM WELL LOG Date of test - Static water level - It. Well production - g.p.m. WATER SAMPLE RESULTS: Coliform NF.G colonies/100mL Nitrate ND Arsenic: ND mg/I Date of sample: 03/04/201_1 B. SEPTIC/HOLDING TANK DATA __ Well Log (Y/N) N VVires properly protected (Y/N) X Casing height (above ground) 1_2+ in. AT INSPECTION 3/23/2011_ 204 It. 1.1 g.p.m. Date of adequacy test 3/24/2011 Results (Pass/Fail). Pass For__ Fluid depth in absorption field before test 22.$ in. Water added 600 gal. Elapsed Time: 1_4~,0 min. Final fluid dePth 21.6 in. AbsorPtion rate >= Any rejuvenation treatment (past 12 mo.) (Y/N & type) N__if yes, give date --_.- 3 bedrooms New depth 39.6 in. 450+ g.p.d. Tank Type/Material SepficJ/*/DPE Date installed 6/15/2000 Tanksize 1030 gal. Number of Compartments _2 Cleanouts (Y/N) _Y Foundation cleanout (y/N) Y* Depression over tank (Y/N) N__ High water alarm (Y/N) N Date of pumping 1_0/1_~,/20'1o Pumper Sanitary C. ABSORPTION FIELD DATA Date installed 6/15/2000 Soil rating (g.p.d./tt~ or ff2/bdrm)0.45 System type Deep Trench Length 72 ff. ' Width 2.5 ff. Gravel below pipe ?.o1 ff. Total depth 1_2.¢ ff. (Measured 3/23/11) Eft. absorption area 1009 fi2 Monitoring tube Y Depression over field N__ Parcel ID: 051-064,-76 Collected by:. ArcTerra D. LIFT STATION Date installed "Pump on" level at__ Datum in. E. SEPARATION DISTANCES Size in gallons "Pump off' level at~ Cycles tested in. Manhole/Access (Y/N) High water alarm level at in. Meets alarm & circuit requirements? SEPARATION DISTANCES FROM WELL ON LOT TO: septic tanldli~ station on lot 100'+ Absorption field on lot 100'+ Public sewer main Sewer/septic service line 25'+ Animal containment areas SlY+ On adjacent lots 100'+ On adjacent lots 100'+ Public sewer manhole/cleanout 100'+ Holding tank 100+ Manure/animal excrete storage areas 100'+ SEPARATION DISTANCES FROM SEPTIC/HOLDING TANK ON LOT TO: Building foundation 5'+ Property line 5'+ Absorption field Water main 10'+ Water service line 10'+ Surface water I00'+ Wells on adjacent lots 100'+ SEPARATION DISTANCE FROM ABSORPTION FIELD ON LOT TO: Property line 10'+ Building foundation 10'+ Water Service line lo'+ Surface water 100'+ Curtain drain 50'+ (None Known) COMMENTS Water main 10'+ Driveway, parking/vehicle storage Wells on adjacent lots 100'+ *FC0 located inside basement. casing probed/verified to 40'. ENGINEER'S CERTIFICATION I certify that I have determined through field inspections and review of Municipal records that the above systems are in conformance with MOA COSA guidelines in effect on this date. Engineer's Printed Name K~NNETH M. DUFI~S Date 03/28/2011 COSA Fee $490.00 Date of Payment Receipt Number (Rev. 11/05) Vacant field presoaked (2000 gall) prior to adequacy test. See attached documentation letter. Waiver Fee $ ~OO' ~' Date of Payment t'~/~/l' Receipt Number b ! ~'"o°~ ~'~ Well HOUSE DETAIL HOUSE LOT 4 LOT '5 ,THE V/HIGH ~URV[.JY,' .CF&RDFICA D~N Pr~ep.0red by Robert E.', Johns:, d:r. ~ ASsOc. Profe'ss~onr~ Lend"Surveyors 03/23/11 VOYLES 'BLOCK t LOT'3B U4/U4/Z011 13:13 FAX ~001/001 ARCTIC PUMP & WELl. INC. Jim Sullivan I'0 l-lOx 770197 Eagle River, AK 99577 (907) 688-251 (! (907) 258-2510 (907) 745-25 } 0 Pump Installation Log Well Drilling Permit Number: Parcel Identification Number: SW Date Of Issue: Legal Description Voyles Property Owner Name Address: John Graybill Lot: 3b Block: 1 AK Pump Installaion Date: 12/15/2010 Pump Intake Depth Below Top of Well Ca$in 221 Pump Manufacturer's Name Franklin Pump Model: 7JS07S4 2W230 Pump Size: 3/4 Pities$ Adapter Burial Depth: 11 Feet Pitiers Adapter Manufacturer's Name Baker Pitles$ Adapter Installer: Dean Construction Welt Disinfected Upon Completion? Yes Method of Disinfection: Chlorine Comment~: 199 static 231 deep casing 40'+ with no preforations Monda. v, April 04, 2011