On-Site Wastewater Disposal System and/or Well Inspection Report
F~ ~, ~ Wastewater System: D New. D Upgrade
. ~o. ol8~rooms ~DeepTfench D Shallow Trench DBed DMound DOther
WELL: E~T D New a Upgrade Gravelwidlh:
SEPARATION DISTANCES ~sep~ic a Holding 0 S.T.E.P.
Sudace
I
Remarks: ~I~ ,~/~/g~ ~,~ BENCH MARK
v ENGINEER'S SEAL
Inspections performed by:. FI~F~.Tec4
Department o[ Health and Human Services approval ': ~' ' --
I
PERMIT NO: SWOOOO88
I
PID NO: 015-482-14
SVV~NG TIES:
FROM: COR."A" COR."B"
TO:
S,T. C.O. "C" 25.5' 36.5'
S.T.C.O. "D" 24' 41.5'
DBL C.O. "E" 19.5' 43'
VALVE "F" 24' 42'
DBL C.O. "G" 28' 46'
TR. C.O. "H" 53' 67'
TI~ M.T. 'T' 56.5' 50'
TI~ C.O. "J" 7t.5' 49'
R 100'
WELL
NEW 1000 GALLON
SEPTIC TANK.....'
PAGE 2 OF 2
ORIGINAL
W. 6.1' SEWER GVL. BELOW PIPE
, T.H. T.H.
', #2 #1
PLAN VIEW
SCALE: 1" = 30'
~ INS. 2' SOIL COVER ~
96.2 'SEPTIC TANK,, \INV
ELEV. 78.5' (DRY)
2.0' SOIL COVER
94.1' ,,
, , 94.1'
60' LoNG SOlLABs. TRENCH
W. 6.1' GVL. BELOW PIPE ' '
~'~- BOIl'OM EXCAVATION ELEV. 88.0'--~
PROFILE VIEW
NOT TO SCALE
LOT 130, SEC. 15, TI2N, R3W, S.M.
SEPTIC SYSTEM UPGRADE
AS-BUILT INSPECTION REPORT
FLATrOP TECHNICAL SERVICES
14~30 ECIIO STREET
Al,ICl lOP, AGE, ALASKA 99516
SCALE: AS NOTED
DRAWN BY TFM
OCTOBER, 2000
MUNICIPALITY OF ANCHORAGE
Department of Health end Human Services
On-Site Services Program
825 L Street, Room 502
P.O. Box 196650, Anchorage, AK 99519-6650
(907) 343.4744
ON-SITE WASTEWATER DISPOSAL SYSTEM PERMIT
Upgrade
Date Issued: May 04, 2000
Expiration Date: May 04, 2001
Permit Number: SW000088
Legal Description: T12N R3W SEC 15 LT 130
Design Engineer: 0019 Flattop Technical Services
Owner Name: Pamela A. Barbeau
Owner Address: 4311 E. 104th Ave.
Anchorage, AK 99516-6310
Parcel ID: 015-482-14
Site Address: 004311 104TH AVE E
Lot Size: 46200 SQ. FT.
Total Bedrooms: 3 Permit Bedrooms: 3
This permit Is for the construction of:
[] Disposal Field [] Septic Tank [] Holding Tank [] Privy
[] Private Well
[] Water Storage
All construction must be In accordance with:
1. The attached approved design.
2. All requirements specified in Anchorage Municipal Code Chapters 15.55 and 15.65 and the State of Alaska
Wastewater Disposal Regulations ( 18AAC72 ) and Drinking Water Regulations ( 18AAC80 ).
3. The engineer must notify DHHS at least 2 hours prior to each inspection. Provide notification by calling
(907) 343-4744 ( 24 hours ). ( Not required for a Water Supply Permit only ).
4. From October 15 to April 15, a subsurface soil absorption system under construction during freezing weather
must be either: A. Open and closed on the same day.
B. Covered, sealed, and heated to prevent freezing.
Received By:,
Issued By:
Date: ~Se'-/ ~{0~
Oate:y-¢ -00
CIVIL & ENVIRONMENTAL ENGE'dEERLNG · ENERGY CONSERVATION & ANALYS~
THEODORE F. MOORE, P.E. .14530 ECHO ST.
PH: (90?) 345.1355 ANCHORAGE, ALASKA 995t6
September 27, 1999
M.O.A. DHHS
P.O. Box 19-6650
Anchorage, AK 99519
Dear Sirs:
The purpose of this letter is to provide the required design narrative in support of our application for
a permit to upgrade the wastewater disposal facilities on BLM Lot 130, Section 15, TI2N, R3W, S.M.,
located at 4311 East 104th Avenue. The original soil absorption system is no longer able to accept the
wastewater load generated in the residence. Soils logs, perc test results, a site plan, design drawings
and specifications are enclosed for your review.
The proposed system will be constructed in the vicinity oftest hole 2. As can be seen fi.om the soil
log, the native material between 1.5 and 4.5 feet below ground level is a gravelly silty sand with a
measured percolation rate of 12 minutes per inch. The native material below that depth is a sandy silt
with a measured percolation rate of 44 minutes per inch. The design loading rate from a three-bedroom
residence is 450 gallons per day. Using the soil application rates specified in the wastewater ordinance
the upper stratum can accept 0.8 gpd/sq, ft. and the lower stratum can accept 0.45-gpd/sq. ft. For the
proposed trench with effective 6-foot sidewalls extending from 1.5 to 7.5 feet below ground level the
combined wastewater acceptance rate per foot of trench is (3 x 0.8 x 2) + (3 x 0.45 x 2) = 7.5 gpdA.f.
The proposed 60-foot long trench has a total acceptance rate of(60 x 7.5) = 450 gallons per day.
The topography of'the lot in the area ofthe proposed trench construction slopes downward towards
the south at approximately 8%.
The proposed project will have no significant impact on present or future water supply and
wastewater disposal systems serving adjacent properties, nor will it have any significant impact on
reserved space-surface and subsurface, or on drainage.
Please give me a call at 345-1355 ifyou have any questions on this submittal.
Sincerely,
Ted Moore, P.E.
· LOT 125 ,'
, ,
, ";,,~, WELL
· ,' ~o~=s ' "LOT 130
.......... R ~00' ',
' ' ~EPTIC
' ~WELL
', [ SYSTEM
". ' ~,' ~TRENCH LOT 131
THIS END OF LOT ', / CONSTRUCT ~ LONG
', ~ SOIL ABSORPTION TRENCH ..
, WITH 6' G~. BE~EEN .
' 1.5' & 7.5' ~ELOW GND. L~L '....';
', ROADWAY & PUBLIC UTILI~ ~SEMENT
~ST 104~ A~NUE
LOT 1, FINLEY S~
LOT 130, SEC. 15, TI2N, R3W, S.M.
o WELL AND SEPTIC SYSTEM
SEPTIC SITE P~N
SYSTEM
~OP ~C~C~ SEDUCES 1 INCH = 50 FEET
14:530 ECHO S~ET DRAWN BY TFM
~CHO~G[.~S~ ~]6 SEPTEMBER, 1999
NOTE: THIS IS NOT A SURVEYED P~T.
ALL LOCATIONS SHOWN ARE APPROXIMATE.
~ DOUBLE C.O.-~ //~ ~.~ TO ORIGINAL TRENCH
WASTE LINE ~ . .
M HOUSE ~X~ ~ / ~ BULL RUN
FRO ~,~) (~=~ DIVERS,ON VALVE
NE~V 1000 GAL ,,
~ ~ ~ ~ ~ 4 DI~ ASTM D-3034
SEPTIC TANK
~'~ NON-PERF. PIPE
NEW 60-FOOT LONG SOIL ABS. TRENCH 'A ' r~ j .4- DI~ ASTM F-810
W. 6.0 FEET GRAVEL BELOW DIST. p-~_-: .-~.? ! .i//'..[~':: .~;~ PERF. PIPE
~ .......................... :=::oI,
PLAN VIEW
SCALE: t" = 10'
CLEANOUT
MONITOR TUBE
MOUND BACKFILL 1.25 FEET
ORIGINAL GROUND
BOSOM OF ~CAVATION
X-SECTION "A - A"
SCALE: 1" = 5'
LOT 130, SECTION 15, TI2N, R3W, S.M.
SEPTIC SYSTEM UPGRADE
PLAN AND CROSS-SECTION
FLATTOP TECH]~qCAL SERVICES
14530 ECltO STREET
ANC!IORAGE, AK, 99516
SCALE: AS S11OWN
DR~WN' BY: TFM
SEPTEM]BER, 1999
TEST HOLE
FLATTOP TECHNICAL SERVICES
14530 ECHO ST.
ANCHORAGE, ALASKA 99516
SOILS LOG - PERCOLATION TEST
LEGAL DESCRIPTION: BLM Lot 130 Sec~on 16. T12N. R3W S M
DATE PERFORMED: Juh/15. 1999
PERFORMED FOR:.~p_azg_~arb~u
DEPTH~
(feet) P[ andloam
SM Sandy, gravelly loam
ML Sandy silt
Damp, dense
MI/GM Sandy silt
Dry, softer lflan overtying ML
Pockets or rocks end gravel 6' - 8'
SLOPE
8%
ML Sandy silt
Dry, dense
Harder digging
17 BH.
18-
19-
20-
Depth to Groundwater Date
..Nq groundwa[~r 7/15/gg
Momtor tube dry 7~2/99
O%
Clock Net Time Percometer Net Drop
Date Reading Time (minutes) Reading (inches)
7115 12" Presoak O
7/22 1Z' Resoak
Start 3:06 25 11116
#1 3:36 30 25 11116
#2 4:06 30 24 3/16 13116
#3 4:36 ~g 23--~/~6 j 718
PERCOLATION RATE 44 (minutes/inch) PERC HOLE DIAMETER
TEST RUN BETWEEN 8.5 FT AND 90 FT
COMMENTS:
PERFORMED BY FLATTOP TECHNICAL SERVICES. I ~.~/~.~ CERTIFY THAT THIS TEST WAS PERFORMED IN
ACCORDANCE WITH ALL STATE AND MUNICIPAL GUIDELINES IN EFFECT ON THIS DATE. DATE: ~ / 3. Z./,~,9
TEST HOLE
LEGAL DESCRIPTION:
DATE PERFORMED:
PERFORMED FOR:
FLATTOP TECHNICAL SERVICES
14530 ECHO ST.
ANCHORAGE, ALASKA 99516
SOILS LOG - PERCOLATION TEST
BLM Lot 130 Se~en 15 TI2N R3W. S.M
July 15. 1999
Para Barbeau
DEPTH
(feet)
13-
'14-
15-
16-
17
18-
19-
20-
COMMENTS:
Pt
SM Reddish silty loam
SM Gravelly, siltysand
Loose. dry
ML Dry sandy silt
Similar to stratum perc'ed in TH #1
SLOPE
J8%
SITE PLAN
\ RENC H 111
I
....... .......
Depth to Groundwater Date
_bl.0_groundwat er 7115LgL
Monrtor tube dry 7/22/99
0%
Date Reading Clock Net Time Percometer Net Drop
Time (minutes) Reading (inches)
7115 12" Presoak I
7/2~ , 12" Resoi).k 5 ~
Add water & start :~L03 10 1/4
#1 3L33 30 12 314 2 1/2
Add water 3:34 10 114
#2 4:04 30 13 2 3/4
Add water 4:04:45 10 118
#3 4:~:-~5 30 1:~ 2 718
I
PERCOLATION RATE 12 (rninutes.qnch) PERC HOLE DIAMETER
TEST RUN BETWEEN 2.5 FTAND 3.0 FT
Monitor tube remained dry despite heavy rain durinq past week with test hole only partial/~/y backfilled.
aII
PERFORMED BY FLATi'OP TECHNICAL SERVICES. I ,~/'...g.~"~ '/] ~ CERTIFY THAT THIS TEST WAS PERFORMED IN
ACCORDANCE WITH ALL STATE AND MUNICIPAL GUIDELINES IN EFFECT ON THIS DATE. DATE: September 22, 1999
3.0 Soil absorption system:
3.1 The soil absorption system shall be constructed by excavating a 60-foot long trench to a depth of
7.5 feet below original ground level in the location shown on the site plan. The long axis ofthe trench
shall parallel an existing contour of the land.
3.2 The bottom ofthe excavation shall be level. Any compacted or smeared surfaces shall be raked
to allow proper infiltration. Sand for leveling or serving as filter material shall comply with Municipal
specifications.
3.3 A total of 6.5 feet of approved sewer gravel shall be placed in the bottom of the excavation with
the perforated distribution pipes laid level such that the pipe inverts are no less than 6.0 feet above the
bottom of the sewer gravel. Sewer gravel shall be 0.5" - 2.5" screened gravel, with less than 3% passing
the #200 sieve.
3.4 Monitor tubes and cleanout pipes shall be of 4" diameter and installed in the locations shown on
the design drawings. The portion of the monitor tube extending through the sewer gravel shall be
perforated.
3.5 Approved filter fabric shall be placed over the entire top surface of the sewer gravel. A
minimum of 2 feet of soil cover is to be placed over the filter fabric. Ifthe soil cover thickness is less
than 3 feet, two inches of rigid, burial type insulation is to be placed over the entire top surface of the
gravel, in addition to the filter fabric.
3.6 The top surface ofthe cover material shall be raised a minimum of 15 inches higher than the
surrounding terrain to allow for subsequent settlement, and shall be graded to smooth contours. Fill
slopes shall be no steeper than 3:1. The area around the trench shall be graded to direct runoff away
from the trench.
3.7 Unless specifically agreed otherwise the homeowner shall be responsible for arranging to have
the site finish graded after the backfill material has stabilized, and for placement of adequate topsoil and
seed to promote rapid revegetation of all areas disturbed by the construction.
4.0 Inspections:
4.1 Aminimum of 4 engineering inspections will be required during the course ofthe project: (1)
initial stakeout with the contractor to establish the location of the system and to discuss the plans,
specifications and construction procedures, (2) at, er the native material has been excavated to expose the
infiltrative surface to ensure that it is level and at the right elevation, and conforms with the soil test
information, (3) after the sewer gravel is in place and the distribution pipes have been laid and connected
up to the septic tank, but prior to placement of insulation or filter fabric, and (4) after rough backfill and
grading is complete. The septic tank requires one inspection after it is set level and the piping
connected, but prior to backfill. This inspection may be incorporated with any ofthe above inspections.
4.2 The installer shall coordinate the timing of the inspections with the engineer sufficiently far in
advance to ensure the availability of the engineer.
Flattop Technical Services
14530 Echo Street, Anchorage, AK 99516
Phone (907) 345-1355
BLM Lot 130, Section 15, TI2N, R3W, S.M.
4311 East 104th Avenue
Wastewater disposal system installation
Specifications
1.0 General:
1.1 The scope ofthe project consistsofreplacement oran existing 1000-gallon septic tank with a
new one and construction ora new 60-foot long soil absorption trench with a total of 6.5 feet of sewer
gravel.
1.2 Construction shall be as depicted on the approved site plan and design drawings. Minor
deviations from these drawings may be allowed or required by the engineer conducting the inspections.
All construction procedures and material specifications shall conform to Municipal and State
requirements. All separation distances shall be in conformance with Municipal requirements, unless
specifically waived.
1.3 The contractor shall be responsible to obtain any necessary utility locates, and to work around
any buried utilities.
i.4 The contractor shall provide adequate cover material and rough grading over all system
components to ensure that proper drainage is achieved a~er settlement and that there are no residual
depressions. Insofar as possible the contractor shall minimize damage to trees and existing lawn areas.
1.5 Unless specifically agreed otherwise, the homeowner shall be responsible for finish grading
after the soil is compacted, as well as placement of topsoil and reseeding all areas disturbed by the
construction.
2.0 Septic Tank:
2.1 The existing septic tank may be retained in service, only if it's structural integrity has been
verified by the inspecting engineer, and if it has functional cleanout pipes with airtight caps, allowing
pumping access to each compartment. Any existing septic tank or seepage pit which is not retained in
service must be properly abandoned by thoroughly pumping, removing the top and backfilling with soil.
2.2 The new 1000 gallon, 2 compartment septic tank shall be Municipally approved and shall be set
level on undisturbed soil. Each compartment shall be equipped with a watertight manhole cover and a
4" cleanout. Ifthe tank is buried less than 4 feet, it shall be insulated with 2 inches of approved burial
type, rigid insulation.
2.3 All pipe connections to the tank shall be equipped with waterproof mechanical couplings. The
waste line from the residence to the septic tank shall have a minimum slope of 1/4"' per foot, and the
waste line between the tank and the soil absorption system shall have a minimum slope of !/8" per foot,
A cleanout shall be installed within 5 feet of the building foundation, and a double cleanout shall be
installed within 5 feet downstream of the septic tank. A "Bull Run" diverter valve shall be installed
downstream of the double cleanout allowing future reconnection to the original trench, if desired.
MUNICIPALITY OF ANCHORAGE
DEPARTMENT OF HEAl. TH 8z ENVIRONMENTAL PROTECTION
ENVIRONMENTAL ENGINEERING DIVISION
825 L Street- Anchorage, Alaska 99501 'Felephorm 264-4720
ON-SITE SEWAGE DISPOSAL SYSTEM AND/OR WELL INSPECTION REPORT
MAILING ADDRESS f) ~ f .)~
~ell
J IF HOMEMADE: Inside length
Well
DISTANCE TO:
Dwelling
Width
DISTANCE TO:
No. of Ib~
Top of tile to finish grade
Type of crib
Width
Crib diameter
Crib depth
Well Building foundation
DISTANCE TO:
Class Depth Drillel
NO. OF BEDROOMS
No, of e~ mpartment~
Liquid dopth
ITotal effective absorption
Nearest lot
Distance to Jot line
Septic tan
PERMIT NO.
Liquid capacity in gallons
PERM,T
els [a nc~w/~ ?es --
,ot~T~e~sorl)tion area
PERMIT NO.
PERMIT NO.
DISTANCE TO: 13uilding foundation Sewer line Absorption area(s)
OTFIER
PIPE MATERIALS
SOIL TEST R ATIND
INSTALLER
REMARKS
APPROVED ~ /~ /" //.- DATE
?~013 (Rev. 3118~ --
LEG L
PEF?.MIT NO.
FIF'PL I CFINf
LOCFFr' I Obi
LEGFIL
bL I .................
STE'v'E RMS"I"RLIp -I. 4 _ -IE, U:, 1 hiE:,::, F:'K.__
U., fl · LL.E r [:'EI4¢~RT
LOTt]:O ~5±ST:L2NR31.q LO-I' SIZE 40000 S6!LII::IRE[ FEET
'I"¥PE[ OF' SCIII_ FflE~SCII:[:F:'q"ION SYSTEM IS: YRENCH
HR>::II"IUM NUMBER OF BE[:,ROEIMS .--= ;3:
SOIL RR'f'ING ,::S.6-.! F]",-"E:R)= ±50
THE t,?EQU:[F?.E[:, SIZE OF THE :E;OIL RBSORPTION S"r'STEM I!5:
THE LENGTH [;,Ih'IENSION I:.~; THE: LIZNG'FH (IN FEET;' OF THE TI;'.ENE:H OR [:,RF~INF;'IEL[:,.
THE DEPTH OF FI TF:E'.'hlCH 0[4: F'IT IS THE [:,ISTRNC[:.' BE-f'HEEN TFIE SIJRFFICE Eft: 'rile
GROI_IND FIND THE BOTTOM OF' ]"HE EXCFIVRTION ,::IN FEET).
TlflERE IS NO SET 1.4IDTH FOR TRENCHES.
THE GRIq'v'EI._. DEPTH IS THE HINIt,'IUM [':,EF'TH OF GRFtVEL BETklEEN THE OLITI='I::t[J... PIPE
FIt.,ID THE BOTTOH OF THE EXC:FI'v'RTION ,:; IN FEET;,.
F'I.ZRHI T FiF.~F'LICFINT HFIS THE REL:;F'ONS I[3 IL I"F'¢ -FO INFEIRt,'I THIS [:~EF'FIRTMENT I>I_IRING THE
I NSTRLLFI]"ION J:t-,ISSF'E):]:]-IEtN'.:~; ElF RN'¢ I.,IELLS R[.',JlaCENT TO THI!.:'; PROF'ER]"¢ FIN[':, THE
NLIHBEF: OF RESIDENE:ES ]'HFIT THE 1.4ELL. klILL SER',,,'E.
E:FIE:KF;[L.L. ING OF' FIN"r' L:;'¢STEM NI-f'HOUT FI NFIt_ INSPECTI ON RN[:' FIPPF?.OVf:IL. E:',r' 'THIS
DEF'Fff~'.THENT HILL BE SUB.]'ECT TO PROSEL~:U]"ION.
I"IlIqIMUH D I~'3'f'FINCE BETI.,IEEN R NELL. Fii',lD FIN"r' ON'-''''''''ITE [SEI.,IFIGE D ISF'OSIqL '3'¢STEM IS
±OO FEET FOR FI PF:i',,"RTE HELL OR ±50 TO 200 FEET FROM R F'UE~LIL: 1.4EL.L DEPEN[.:,:[NG
UPON THE "rYF'E OF I::'UE',LZC HELL.
HINIMIJh'I DISTFINCE IrzROH FI F'RI'v'FCFE NELL ]"O R PRI'v'FITE SEFIER LINE IS 25 FEET RND
TO FI E:OHHIJNIT"t SEI.4ER LINE 1;'.:5, 75 FEET.
I,.IELL LOGS RRE REC..!UIF'::E[:' RND MUST BE RETLIRNEC, TO THE B, EF'FIRTMENT 1.4I-Ft~IIN 30 DFIh"S
OF: -I'HE 14ELL COMF'LIETION.
O'FHER REg!UIREMENTS t'IFI'¢ RPF'L."r'. SF'ECIFIC:RTIONS RN[:' CONSTt',:'.'LIC-I"ION DIFtGRI::tHE; RF'.E
I::t',,,'R I L.I::IE~LE -ro INSURE F'ROF'EF'. I NSTFIL.I_RT I ON.
I
F:ORTH [-'?¢ THE HUN ICIF:'FILIT"r' OF F]NCHORFI(.~E.
2: I NILL II",ISTFILL THE S'¢F';TEH IN FdCCOR[:,FINCE HITH THE CEd)ES.
_"i~: I IJN[)ERSTFIN[:, TI-IFFF THE ON'"'S'ITE SEHEF'. Sh"STEH HFI"? F'.E6:!UIF4'.E
RES, I[>ENCE IS RE:MOI:>ELED-FO It,ICLU[:'E i',lOr~'.E TFIiqt.4 2: E:E[:,I4:OOMS.
--:-C?/
.~"' FIPI::'L:~ CFINT STE'v.~' FII"E:iTRUP
ISSUE[:, '::'~,~. ~-.~,~::
CEF:TIF¥ THFI-I~
I FIH F'FII"II[._IF~R HITH THE REL.qUIREHENTS FOR ON-SITIE SEI*I[i~I~:.'.:.'; RI'.,ID [,.IELJ_.S FISS SET
EhlLFIRGEh'IEt,IT IF THE
[~$OI LS LOG
MUNICIPALITY OF ANCHORAGE
DEPARTMENT OF HEALTH AND ENVIRONMEN'FAL PROTECTION
825 L, Street, Anchorage, Alaska 99501 264-4720
SOILS LOG - PERCOLATION TEST
PERCOLATION
TEST
PEREORMED ED.: ~LL ltd L t~o~-~
~EOA'DESCR,PT,ON: Log-/Jo
2
4
5
6
7
9
10
11
12
13
14
15
16
17
18
19
20
SLOPE
COMMENTS__
WAS GROUND WATER
ENCOUNTERED?
IF YES, AT WHAT
DEPTH?
S
P
E
G*oss Net Depth to Net
Reading Date
Time Time Water Drop
'ERCOLATION RATE /1 (minutes/inch)
TEST RUN BETWEEN
CERTIFIED BY:
72-008 (6/79)
6
DATE RECEIVED
INSPECTION APPOINTMENTS
TIME TIM~ TIME
INSPECTOR INSPECTOR INSPECTO~
MUNICIPALITY OF ANCHORAGE .
DEPARTMENT OF HEALTH & ENVIRONMENTAL PROTEC~ICIPALI 'Y OF ANCHORAGE
ENVIrONmENTAL SANITATION DlVlSIO~
Telephone 264.4720
DIRECTIONS: Complete all parts on page 1. Incomplete requests will not be processed, Please allow ten (10} days for processing.
1, PROPERTY O~NER '~b PHONE --
PROPER-FY RESIDENT (If different from above) ' PHONE
MAILING ADDRESS
~ LE~DING INSTITUTION PHONE --
4. REAL~OR/AGEN'r [ PHONE
MAILIND ADDRESS
E, LEGAL DESCRIP'I'ION
STREET LOCATION
6. TYPE OF RESIDENCE NUMBER OF~I3EDROOMS
,~ -Z_ One [] Four
SINGLE FAMILY ~ Two I-] Fiva
[] MULTIPLE FAMILY [~ Three I-~ Six
[] Other
WATE.:R UPPLY
INDIVI DUAL* ' ATTACH WE LL LOG. A well log Is required for al walls drilled
'l~J COMMUNITY since ,June 1975. For wells drilled prior to that date, give we
[] PUBLIC UTI LITY de,th (attach log if available,)
S, SEWAGE DISPOSAL SYSTEM
~ NDIVIDUAL/ON-SITE*' ~ C~ I YEAR ON-SITE SYSTEM WAS INSTALLED.
[] PUBLIC UTILITY
NOTE: THr[ INSPECTION FEE MUST ACCOMPANY EACH REQUEST BEFORE PROCESSING CAN BE INITIATED,
THIS SIDE FOR OFFICIAL USE ONLY
I. TYPE OF RESIDENCE NUMBER OF BEDROOMS
[] SINGLE FAMILY [] ONE [] THREE [] FiVE [] OTHER
[] MULTIPLE FAMILY [] TWO [] FOUR [] SIX
PERMIT NUMBER
2. WATER SUPPLY
[] INDIVIDUAL DEPTH OF WELL
[] COMMUNITY
DATE DR I LLE D
[] PUBLIC UTi LITY
Connection Verified LOG RECEIVED
3. SEWAGE DISPOSAL SYSTEM PERMIT NUMBER
[]INDIVIDUAL/ON -SITE DATE INSTALLED
[]PUBUC UT UTY
Connection Verified INSTALLER
[]Septic Tank or []Holding Tank
Size; ?(::i'~'~,')t-'~ If Tank is Ilomemade SOILS RATING
i§ive dimensions:
TYPE OF TANK MANUFACTURER . /~{J.~0~--
TOTAL ABSORPTION AREA MATERIAL
4. DISTANCES WELL TO: Septic/Holding Tank Absorption Area Sewer Line Nearest Lot Line
Absorption Area to nearest Lot Line
5. COMMENTS
[~"~APPROVED FOR ~ BEDROOMS
[] CONDITIONAL APPROVAL (letter must accompany certificate)
[] DISAPPROVED
DATE BY
72-010 (Rev. 6/79)