HomeMy WebLinkAboutT12N R3W SEC 27 LT 54 REMTI2N R3W
Lot 54
¢¢018-092-48
: Municipality of Anchorage
Department of Health and Human Services
Division of Environmental Services
On-Site Se~ices Section 825 't.' Street Room 502
P.O. Box 196650 Anchorage. AK 99519-6650 Page I of 3
www.ci.anchorage.ek.us (907) 343-4744
ON-SITE WASTEWATER DISPOSAL SYSTEM AND/OR WELL INSPECTION REPORT
Permit Number~ SW000220 PID Number: 018-092.48
,..... Wastewater System: [] New [] Upgrade
Crnl0
42.;1 D~Armotm Rnnrl_ Aneh_ AK .q_q5lR ABSORPTION FIELD
LEGAL DESCRIPTION 0,5 ~"~f 8.5-10
54 SW4 1.3-3.3
12N 3W $,~ ~7 3
Well: [] New [] Upgrade o~,v~.,,~: 313
Exlst'q Private ~,, ~, 1500 ~ F81013034PVC
~, Owner 101'112000
SEPARATION DISTANCES ~ sep~c ~ Ho/ding D S.T.E.P. ~ ~het:
Septic ~fpfion ~ Holding Pu~at* ~: ~:
Tank
250
Tank Field S~fion Tank s~. u.. Anchorage
wa 105 107 S0 Steel 2
s~w,,~ 100+ 100+ ~ / LIFT STATION
L.~. 35 22
c.~. ~,~. 100+ 100 ~"~"
"~: BENCH MARK
~ lC A~~ ~ ~ ~' West Door Threshhold
101.2
Engineers Stamp
.......
Inspe~ions ~do~ed by: Pannone Enq. Svc Dates: 1"9130/2000
2~ OlO ~ 12000
Depa~ment o[ ~oalth and Human So~m~' appr~ -
Reviewed and approved by: f).~/_ ~ /~. ~Date: ~
NO, SV000220 AS-BUILT P.I.D. NO, 018-092-48
WASTEWATER ABSORPTION SYSTEM
LOT 54, SW4, S27, T12N, R3W
?x NEW 1~50L
IN FAILURE, g /~vY7 ~'iTRENCHES
TO REMAIN ~~~%~ 5~LFx3'x7.5'EA ~%/ ;:
NE~ DIVERTEE ' '~
V~LV[ ~ DOUBLE~ ~c/~4 i ~
CLEAN-nUTS T~ ~ ~ /
ND VELLS VITHIN
~00' OF PROPDS~
;YST~M, DTH~R THAN
SHDVN,
DE ARHDUN RDAD
CO A B
T1 72.7
~o~kSDRA~INGS54S~4S~7~I~NE3~,D~O T~ BO.7 9B.5 DESIGN,
CI 79,3 98.0 4 BEDROOM HOUSE
~t~I~ M1 81.3 94.4 PERC RATE 45 MIN/INCH
~~ C3 85.6 87,4 7,5' EFFECTIVE
~e Ca lag,O ~4e,8 t333 SF REOUIRED
~ X~ C4 1905 138.0 1U' TOTAL DEPTH
.............. ~.....m E1 68.8 74.7 1500 ~F TOTAL
~ E~ 107.6 117.7
Ponnone~'~ Mp. Cp~lg Cupplep P.O. ~OX 108954
~1497~ 4851 DeArnoun Ro~N ANCHORAGE, ALASKA 99510
....... ~., %~ : 272-8818 Phone [ Fox
-e~.~t~ (907) 5E~-BGB7
(907) ~40-~369 DATE, ~0-~-00 ) AS-~UILT
AS-BUILT DETAILS
WASTEWATER ABSORPTION SYSTEM
LOT 54, SW4o S27, T12N, R3W
P,I.I). NO' 018-09~-48
C,\Vork\I)RA~,'ING\54SV4S~7T12NR3V.DVG
o
o
W
PREPARED FOR,
Mr, Ct:lo Currier
4~51DeArmoun Ro~
Anchorage, AK 99516
(907) 5~-8687
(907) 240-~369
PANNDNE ENG, SVC,
P, D, BOX 102954
ANCHORAGE, ALASKA 99510
272-8218 PHONE & FAX
I
~AT~,
10-11-00
TO SCALEJ AS-BUILT
NOT
MUNICIPALITY OF ANCHORAGE
Department of Health and Human Services
On-Site Services Program
825 L Street, Room 502
P.O. Box 196650, Anchorage, AK 99519-6650
(907) 343-4744
ON-SITE WASTEWATER DISPOSAL SYSTEM PERMIT
Upgrade
Date Issued: Jul 11,2000
Expiration Date: Jul 11, 2001
Permit Number: SW000220
Legal Description: TI2N R3W SEC 27 LT 54
Design Engineer: 0062 Pannone Engineering Services
Owner Name: Craig Currier
Owner Address: 4251 Dearmoun Road
Anchorage, AK 99516-
Parcel ID: 018-092-48
Site Address: 004251 DE ARMOUN RD
Lot Size: 54450 SQ. FT.
Total Bedrooms: 4 Permit Bedrooms: 4
This pen'nit is for the construction of:
[] Disposal Field [] Septic Tank [] Holding Tank [] Privy
[] Private Well
[] Water Storage
All construction must be In accordance with:
1. The attached approved design.
2. All requirements specified in Anchorage Municipal Code Chapters 15.55 and 15.65 and the State of Alaska
Wastewater Disposal Regulations ( 18AAC72 ) and Drinking Water Regulations ( 18AAC80 ).
3. The engineer must notify DHHS at least 2 hours prior to each inspection. Provide notification by calling
(907) 343-4744 ( 24 hours ). ( Not required for a Water Supply Permit only ).
4. From October 15 to April 15, a subsurface soil absorption system under construction during freezing weather
must be either: A. Open and closed on the same day.
B. Covered, sealed, and heated to prevent freezing.
Received
Date: 7'""//'~'~0
Consulting Engineer
(907) 272-8218
P.O. Box 1420~
Anchorage, Alaska, 99514
(907)272-8218 Fax
Ju~ 8,1999
Municipality of Anchorage
Dept. of Health &, Human Services
On-Site Services Section
P. O. Box 196650
Anchorage, Alaska 99519
Subject:
Lot 54, SW4, T12N, R3W
Emergency Septic System Upgrade Permit
Oentlemen:
My fLrm was contacted to investigate n failed system at the above referenced property. When I
arrived, sewage from the drain field was day lighting on the ground. The Owner commissioned
me to design and install n new septic system for this lot. We conducted a field investigation to
locate existing wells and septic system before designing the proposed system. One test holes
were excavated on July 1, 2000 for the system design, which is attached. No ground water was
encountered. No bedrock was encountered in the test hole.
The lot is approximately 2.5 acres in size. Lot 54 slopes to the south at a rate of approximately
2-3 percent. The proposed installation will be located on the northern portion of the lot in a
relatively flat area. A new septic tank will be installed outside the 100-foot well radius. The
proposed location is adjacent to the existing drainfield and is greater than 200 feet mvay from
any wells. A private well, located in the north serves this lot east corner of the lot. The proposed
system will be greater than 10 feet from the water service lines. The proposed installation ~11
not affect the future development of the surrounding or existing lots. See the attached design.
The Oxvner is an experienced excavator and is planning to install his oxvn system under my
direction and supervision.
installation.
Sincerely,
~one, P.E.
Attachments:
Please contact me at 272-8218 or 227-3522 if you have any questions about the proposed
............................ .,....;
-
~ f~%%levon R. Pon~one,~j~
C:\WORKXI.] ~r I'1 :.RS%.MSW41' 12 N I~JW.IM) LIX X;
PERMIT NO, DESIGN P.I.~. NO,
WASTEWATER ABSI]RPTIDN SYSTEM
LOT 54, SW4, S27, T12N, R3~/
A~aN~BN IN PL~E ~ ~ ~% ~
IN FAILURE ~ ?Y ~1111 v .F*~ ~ ~PRDPDSE9, ~ UPO~
TD REMAIN ~ ~ t~t III ~.., ! ~ TRENCHES 5~
NO ~ELLS ~ITHIN
200' DF PRDPDS~
;YSTEM, DTHER THAN ~
SHDVN. ]
DE ARMOUN ROAD
1333 SF REQUIRED
~ ~$a 7.5' EFFECTIV[
49~ ~ S~ ~ 1~' TDTAL DEPTH
~~~~~~'~ PREPARED FOR, P ANNDNE ENG, SVC
- M~. C~19 Curlier P, D. BOX 108954
9951~
~.._~ 272-B21B Phone & F~x
F~ [~i~ (907) 522-8687
'S$~~ 1907> E40-E369 3ATE. 7-B-O0 I DESIGN
· m~- SCALE'
PFRMIT NO,
DESIGN DETAILS
WASTEWATER ABSORPTION SYSTEM
LOT 54, S~/4, S27, T12N, R3~/
P.I,D. ND'
C,\WorR\DRAWINr,\54%W4 S27T12NR3W.DVr,
PREPARED FI]RI
Mr. Craig Currier
425! DeArmoun Ro~zd
Anchor~geo AK 99516
(907) 52P-8687
(907) 240-23G9
W
PANNDNE ENG. SVC.
P. 0. BOX 102954
ANCHDRAGE, ALASKA 99510
272-8218 PHONE & FAX
DATD 6-28-00
NOT TO SCALE DESIGN
~OIL8 LOG - I~RCOLATION ~
PANNONE ENGINEERING SERVICES, LLC
P.O. BOX 102954
ANCHORAOE~ AI~ 99510
(gO7) 27~-8~8
PERFORMED FOR: Mr. Ces/~ Currier
LEOALDESCRIPrlON: Lot 54~ 8W4tT12N,R3W
OR
GM
DATE PERFORMED: 7-1-00
BOH
Gray Silty Grovels
with Cobbl~
or~ orsve~
SLOP~
~ HOI~
WAS GROtlND WATER
ENCOUNTERED?
1~ YES, AT WHAT
DEPTH? ~
DEPTH TO WATER A~-I'~R
MONrrORINO? Dry
DATE: 7-8-00
~o
TE3T HOLE
7-1-~ 19,45 ~ 6'
PEROLATION RATE 45 {mtn/inch] PERC HOLE DIAMETER 6 inches
TEST RUN BEWTEEN 7 P'I' and 8 FT
COMMENTS: Test hole excavated by Owner. Test Hole was presoaked before perc test.
PERFORMED BY: Scott Crowther~ P.E. I CERTIFY THAT THIS TEST WAS PERFORMED IN ACCORDANCE
WITH ALL STATE AND MUNICIPAL OUIDLINES IN EFFECT ON THE DATE OF THIS TEST.
GREA ER ANCHORAGE AREA BOk.,dGH
~;, · ,',, Department of Environmen'tal Quality
~,-~' 3330 C Street
Anchorage, Alaska 99503
INSPECTION REPORT ON-SITE SEWAGE DISPOSAL SYSTEM
SEPTIC TANK:
DISTANCE
FROM WELL ~-'~(~'¢~
INSIDE LENGTH_
MANUEACTURER~--- MATE RIAL ~__L~
INSIDE WID1N __ LIQUID DEPTH
NUMBER OF
COMPARTMENTS
LIQUID CAPACIT~ GALLONS.
TILE DRAIN FIELD:
/ .. f /0{ TOTAL LENGTH ~,~.~"" /
DISTANCE FROM WELL_ ~0~ FOUNDATION 70 NEAREST LOT LINE OF LINES
NUMBER OF LINES _~--- DISTANCE BETWEEN LINES -.~/~ TRENCll WIO IN. TOTAL EFFECTIVE
ABSORPTION AREA *¢~¢ Sq. FT. LENGTH OF EACH LINE
DEPTH: TOP OF'FILE TO FINISH GRADE ~ ¢ DEPTN OF FILTER ~ ¢
MATERIAL BENEATH TILE (~__~ ABOVE TILE ¢ IN.
WELL: ~
TYPE _ CONST RUCTION
DEPI'H .... DISTANCE FROM:
BUILDING NEAREST
FOUNDATION .__, LOT LIN[;
NEAREST SEPTIC SEEPAGE
SEWER LINE TANK -- SYSTEM_
CESSPOOL
OTHER SOURCES
APPROVED
DISAPPROVED
DISTANCES:
INSTALLED BY:
SEWER LINE DEPTH:
PIPE MATERIAL: ~-,~'7~-'/~r~/~/.
LOT SLOPE: ~-~' ---- '
REMARKS:
REMARKS
DIAGRAM OF SYSTEM
CONSULTING CEOLOGIS1
SOILS LOG
Performed for ~
~pth (feet] Soil I)escription
~qO.~
-20-
'~-otal Depth /f feet
Was groundwater enoou~'bered__~ ?
~epth to bed. rook..? 2~0
__ How determined
Respectfully submitted
Gary P~ P]_ayer
Consulting
~ ~v825
Time
Date ; ~-_L~ <132J_9~,
MUNICIPALITY OF ANCHORA
JF ltEALTH AND ENVIRONMEI'~,' PROTECTION
L Street, Anchorsc~. Al. asks 99501
264-472C
Date Received: October 12, 1977
t~2: Time ~3: Time
Date Date
Insp Insp
REQUEST FOR APPROVAL OF
]_. Lending Institut±on Requesn:
Mailing Address:
INDIVIDUAL SEWER AND WATER FACILITIES
Alaska National Bank of t~e Nerth
Property Owner:
Mailing Address:
3301 C Street,Calais II Phone:
Roger M/Roxanne L. Pike Phone: 349-5141
Star Route A Box 309 99507
3. Legal. Description: T12N R3W Section 27 Lot 54
4: Single Family Residence: ( ~ Number of Bedrooms: ~[
\
Multiple Family Residence: ( ) Numbez of Bedrooms:
5. Well System: Individual well ~ ) Con~unrty/Public System
Permit = Depth of well 146' Well Log on File ( )
Construction
Bacterial Anal. ysms
Sewage Disposal System: On-site Syst~e~m] ~ Publlc utility
PermJ_'t ~t .......... Install d~ 1~ Installer
Septic Tan]< Size Manufacturer
{ )
Absorption Area Solls Rate ManerJ.al
Distances: We].]. no Sepnl. c Tank 'to Absorption Area
to Sewer Line Nearest Lot line AbsorpLion Area
no Nearest I,o'~. Line
Page Two
Department Of
Requesn for Approval
Legal Description:
Comments:
Health and Environmental Protection
of Individual Sewer and Water Facilities
T12N R3W Section 27 Lot 54
Affadavit Attached:
Approved: ~).
Disapproved:
Letter Attached: ( )
Date, /~2~-/7- 77
Date:
Department Worksheet:
MIJNICIPALII'YOFANCItORAGE
I)EPA~tTML-'NT OF ilI~ALTH AND I~NVII~ONMI:.NTAL F'RO'I ECTION
East 'lMdor Road, Aiichol~t Allska 90 0¢ 27g-2221
'U:GLJF-ST FOR AI'!'FIOVAI.. OF
N .I 411.1U;~I SI'WI;It and WATER [-A(.It.I 11:8
,Mailing Adch e.s: ......... ~o~!
Na~e of Realtol oi Atle, I t . . _O~u} '~-~- ...............
Mailing Ac( r~ss' ...... Phone:
Z_
?
8.
Water Supply
rypc of Supply: Public tltlht'~ ........... Individual_._
If Individual, number o dwellings presently so~ved
/
If Individual, depth of well_
Sewage Disposal Syslern
-I'vpe ol System: Pul)he Utility ....... Individt*al (on sin~)._ ..~
)6.12201c
OEPARTMENT OF HEALTH AND SOCIAL SERVI..: t~,'~ .~,:'~'~Lk'.~
DIVISION OF PUBLIC klEALTH LobNc
IHDIVIBUAL AND SEMIJ>UBLIC
BACTERIOLOG I CAL. WATER ANALYSIS
INDIVIDUAL [] SEMI PUBL C ~ CHLORINE RESIDUAL PPM_
RETORT RESULTS TO
CIT'~ .... ZiP CODE.
ADDRESS
OF SOURCE
SANITARIAN S:REMARKS
COMPLETE THIS SEC1
ONLY IF WATER IS AN INDIVIDUAL SUPPLY
0,~. 1220 Ibl BACTEr~i~'ILOGICA L...~
Ro,, ~ WATER ANALYSIS RECORD -
READ INSTRUCTIONS DateReceved r _~ D& ~e ' __Time Received _ C~ pmlab No ' ~'_ .
4~ Hours ' /--~ '
BEFORE t;~c~oso Broth, 24 hfs ~ : 48 hr~ Groin's slam .....
COLLECTING SAMPLE ' -.
· /(,~All%*'"';'r/ P pPr'~.i!~F.~-~AL.'rH A~ ~NV~RONM~:N'rAI~ PRO-rr_-c-r~oN ~8 i
n,,~,~..,/ /825 L Street, Anchorage, Alaska -99501
--~-~~-~ Oate Rec;oived: April 21, 1977
III.: Time __~ :_O_p_.p_.m,._ .... It2: Time tt3: Time
Date ............. 4.-25-77 Monday [)ate Date
Insp Kennedy lnsp Insp
REQUEST PeR APPROVAl, OF INDIVIDUAL SEWER AND WATER F O' '" ,' ~t~l
A.,ILI ±IES
Lending
Mailing
Instituulon Request:
Address: Phon
2,. Property Owner: Roger M/Roxanne L. Pike
blailing Address:
% Connie Fogg 272-0571
Phone: 349-5141
Legal Description: T12N R3W Section 27 Lot 54
Sinqle Family Residence:
Multiple F '
amz]_y Residence:
Number of Bedrooms: 2
Number of Bedrooms:
Well Systera: Public/Communil:y System: ( ) Individual We].].: (~x
Permit It Depth of Well 209' Well Log on File ( )
Construction Bacterial Analysis
Sewage
PermLt ~
Septic
Absorption
Disposal Sysnem: On-site System (x~ Public Utility { )
Insta] ].ed
Instal. let
Tank Size
Man lfa¢;ttlI er
Area
Soils
Rate
Materia.I.
7 Distances: Well ko "e2-
· ,~ -t t. lC Tall]<
tO Sewer Line Nearest Lot line
Absorption Area
Absorption Area
uo N_areote ," - Lot Line
Page T~o
Department of Health and Environmental Protection
Request for Approval of Individual Sewer and Wa%er Facilities
Legal Description: T12N R3W SectJ. on 27 Lot 54
Comments:
Affadavit Attached[: (')
Letter Attached: ( )
Approved: Date:
Disapproved: te: b~-~& ~ ~ ~
Department Worksheet: ~ /J)~ ~~,~a_L~o ~ ,
MUNICIPALITY OF ANCHORAGE ; :,,,[ ~,~,:.~,
DEPARTMENT OF HEALTH AND ENVIRONMENTAL PROTECTION
2510 East Tudor Road, Anchorage, Alaska 99504 276-2221
REQUEST FOR APPROVAL OF
INDIVIDUAL SEWER and WATER FACILITIES
1. Type of Inspection: CMRO. VA FHA
2. Property Owner: /')(_C~,~. ht ~. ~,cJ,,.~3,~..f~, ,' ~ I l/ i
Mailing Address: ?'/' ~1¢;-(~ t,, ~,,~ ,,~, ~ ~DayPhone:
.CONV ~
3. Name of Buyer:
Mailing Address:
Name of Lending Institution:
Mailing Address:
. Day Phone:_
.Phone:
5. Name of Realtor or Agent: )-~ ~=~ t¢ ~: i'/ '( ~ , ~L~ ~ ,~
~'~'
Mailing Address: ~J'/ ~ /.~ ' /"U .~ Phone:
6. Legal Description: ~-zj ~ ~-c~ ~' ,~
7. Type of Facility to be Inspected: ~ No. Bdrms.
8. Water Supply
Type of Supply: Public Utility. .Individual
If Individual, number of dwellings presently served
If Individual, depth of well
Sewage Disposal System
Type of System:
Public Utility.
.Individual (on-site)
,Y
If Individual, date of installation
72-003(3/76)
GREATER ANCHORAGE AREA BOROUG,
HEALTH DEPARq]WENT
327 EAGLE STREET
ANCHORAGE, ALASKA 99501
279-2Sll
INDIVIDUAL SE;PAGE AND ~qATER FACILITIES
FOR
INSPECT:_ -~,
Phone . ~ ~ ~
,'- -~h , <~-~. '-,:_~~-~.~ . 7 . L~hone- .......
~umoer of ~odrooms ~ f
S. l~ell Data:
6. Sewage Disposal System:
A. Septic Tank (If homemade, show diagram on bacR)
~. Manufacturo~~
4. r~t~m,
Approval Request for Se ~e & Water Facilities
Page Two
B. Seepage Pit
1. Size ~-<L/O ~-dl~
C. Disposal. Field
1. Number of Lines
2. Total Length
Required Measurements
A. Well. to Septic Tank~
B. Well to Seepage Pit
C. Well to Sewer Line
D. Well to Property Line._
Well to Other Possible Contamination
F. Foundation to Septic.Tank_~(~
G. Foundation to Seepage Fit~-~f /~
H. Seepage Pit to Property Line__~-_
DISAPPROVED:
APPROVAL VALID FOR ONE YEAR FROM DATE SIGNED.
GREATER ANCtlORAGE AREA BOROUGH HEALTII DEPARTMENT
EDll70