ON-SITE WASTE-WATER DISPOSAL SYSTEM AND/OR WELL. INSPECTION REPORT
Permit Number: SW010166 PID Number: 015-281-08 ,
.~.,: Nastewater System: Upgrade
Larry & Lynette Motz
*~,-: ABSORPTION FIELD
12000 Avion Street Anchorage, AK 99516
n~.: ......,~ s.~ ....Deep Trench
Three
LEGAL DESCRIPTION .45 c~e 10.5
Tract 9 Siefker 2.5 n. 8
1.5 .. 64
Well: Existing :~ n. 1I - n.
~,. ~,.1,024 Fe ASTM D3034 PVC
~,. Acreal~e Systems 7/19/01
¥,,,.. ~ i,~,.s~.,.~,, ic.~, ,,.~,,,~.,,.o.,~.~, TANK
SEPARATION DISTANCES Septic
Septic Absorption Lift Holding ,ubl~l~nvate ..........
Tank Field Station Tank Sewer Li~e Anchorage Tank 1,000
w,, >100' >100' N/A N/A >25' Steel Two (2)
~,.w,,.>100' >100' N/A N/A ~ / LIFT STATION - NONE ON LOT
~u. >5' >10' N/A N/A
F .... >5' >10' N/A N/A ~ ~1
c.~,. None Noted
,~,,,~: BENCH MARK
Existing Septic Tank Was Pumped. Crushed.
Backfilled and Abandoned On Site. Existing
Absorption Bed Was Abandoned In Place. Rear Deck Slab. Southwest Corner of House.
100.0 F~
..-; O~..4/.
.~. ~..... -.....~
Inspections performed by: Mike Anderson Dates: 1". 7/19/01 ,,,-.T.'.~., ....
2''~ 7/19/01 ~ ~:~,~*~t..
Department of Health a0d_ HumAn Services approval ~.G'.~ .. ~,-=. ..~.~
Reviewed and approved by: Date: ~ D'Z. '41 ......... ~, '~£0 r [ SS~,'~,'x '~,
Permit Number SW010166
Page 2 of 3
PID No. 015-281-08
VACANT
.Three
droom
Ezistin9
Well
~fstfn9
Well
A B
S1 106.2 116.8
S2 112.3 123.0
C5 117.7 128.5
M1 179.5 191.5
C6 179.7 191.9
S2
C4 C5
PLAN AS-BUILT
SCALE 1" = 30'
10' utili{y Easement
Municipality of Anchorage
DEVEOPMENT SERVICES DEPARTMENT
4700 South Bragaw Street Anchorage, AK. 99519-6655 - 343-7904
On-Site Wastewater Disposal System or Well Inspection Report
Permit Number. SW010166
Page 3 of 3
2 Insular
000Galton I\
PID NO. 015-281-08
51.0'
96.8
.__G e O~.t e x t it · ._~F a Io ~'~ic .... ?' Insulation _--
~sI ~ Dr'ainf'ietd Rock
84.7j
64' ' I
PROFILE AS-BUILT
Scale: 1= - 10'
~/-'--77.8
ANDERSON ENGINEERING [
P.O. BOX 240773
ANCHORAGE, AK 99524
522.7773 522-6779 (FAX)
MEMORANDUM
DATE: April 28, 2002
TO:
FROM:
Dan Roth
Mike Anderson, P.E.~/~''''''
SUBJECT: Tract 9, Siefker Subdivision
Septic System Construction As.Built
I have modified the septic system as-built for the subject lot to include the distance
between the septic tank and the absorption trench. That distance is shown as 5' on
the attached drawings.
Please let me know if you have further questions.
MUNICIPALITY OF ANCHORAGE
Development Services Department
On-Site Water & Wastewater Program
4700 South Bragaw Street
P.O. Box 196650, Anchorage, AK 99519-6650
(907) 343-7904
ON-SITE WASTEWATER DISPOSAL SYSTEM PERMIT
Upgrade
Date Issued: Jun 06, 2001
Expiration Date: Jun 06, 2002
Permit Number: SW010166
Legal Description: SIEFKER TR 9
Design Engineer: 0014 Anderson Engineering
Owner Name: LARRY L. & LYNETTE MOTZ
Owner Address: 12000 AVION STREET
ANCHORAGE , AK 99516-2161
Parcel ID: 015-281-08
Site Address: 012000 AVION ST
Lot Size: 40500 SQ. FT.
Total Bedrooms: 3 Permit Bedrooms: 3
This permit is for the construction of:
[] Disposal Field [] Septic Tank !-_-j Holding Tank [.~ Privy
[] Private Well
[] Water Storage
All construction must be in accordance with:
1. The attached approved design.
2. All requirements specified in Anchorage Municipal Code Chapters 15.55 and 15.65 and the State of Alaska
Wastewater Disposal Regulations ( 18AAC72 ) and Drinking Water Regulations ( 18AAC80 ).
3. The engineer must notify DSD at least 2 hours prior to each inspection. Provide notification by calling
(907) 343-7904 ( 24 hours ). ( Not required for a Water Supply Permit only ).
4. From October 15 to April 15, a subsurface soil absorption system under construction during freezing weather
must be either: A. Open and closed on the same day.
B. Covered, sealed, and heated to prevent freezing.
Received By: ~~--~" ~
Issued By: ~
Municipality of Anchorage
Development Services Department
Building Safety Division
On-Site Water and Wastewater Program
4700 South Bragaw St.
P.O. Box 196650 Anchorage, AK 99519-6650
www.ci.anchorage.ak.us
(907) 343-7904
ON-SITE SEWEPJWELL PERMIT APPLICATION
FOR A SINGLE FAMILY DWELLING
Parcel I.D. 015-2814)8
Permit N um be r SW O/__.W.~_~O_~_
Property owner(s) Lan"/and Lynette Motz
Mailing address (1) t2000 Avlon Street Anchorage, AK 99516.2t61
Mailing address (2)
Legal description (Lot, Block & Sub'd.) Tract 9, Siefl(er Subdivision
Legal description (Section. Township & Range)
LotSize 40,500
Day phone 522.7773
Zip Code
Acre~
Number of Bedrooms 'rhree (3)
THIS APPLICATION IS FOR:
Sewer Only
Sewer and Well
Sewer Upgrade
THIS PROPERTY CONTAINS:
Hot Tub
Swimming Pool
Therapy Pool
Well Only
Water Storage
Jacuzzi
Water Softening Unit
I certify that the above information is correct. I further certify that this application is being made for a
Single Family Dwelling and is in accordance with applicable Municipal Codes.
(Signature of property owner or authorized agent)
Permit
Date of Payment:
Receipt Number:
(Rev. 12/00)
Waiver Fees:
Date of Payment:
Receipt Number:
May 24, 2001
Municipality of Anchorage
Development Services Department
On-Site Water and Wastewater Program
4700 South Bragaw Street
Anchorage, AK 99519-6650
Subject:
Tract 9. Siefker Subdivision
Septic System Design and .P. ermit Application
Impacts to Adjacent Properties
Dear Onsite Services Engineer:.
The exist n~ absorption bed on Tract 9, Siefker Subdivision has failed, and ~.ep. tic
effluent has-been noted on the ground surface n the area. We are theremre app y ng
for a permit to construct a new septic system on the lot to serve the existing three-
bedroom home. The attached Site Plan and backup documentation Identify the location
and configuration of the new septic system and the para.meters used in the design. It
also shows the location of the existing septic system which was constructed in 1969.
The existing septic tank is inside the 100~.pr.otecti.v.e r. adiu..s and...will, be. properly
abandoned in its current location. Also idemiT~eo are tne location o; tne ~es~ hole and
the neighboring well. Existing drainage patterns are shown and will not be altered by
the development of the lot. We have surveyed the area and the new system will not
conflict with wells already In existence in the area.
A test hole was recently placed on the lot to determine subsurface conditions. Soils
were found to 'be poorly graded fine sands with minor amounts of silt in the upper 4'.
This material was underlain by siltier sands. Pemolation tests in the matedal Indicated
rates approximating 43 minutes per inch. The upper layer percolated much faster, but
the system is designed to accommodate the slower rate. Groundwater was found
dudng the excavation at the 16' level and maintained that level during the monitoring
period. We are therefore proposing to place an absorption trench 63' long by 3' wide
with an 8' effective depth to treat the septic effluent. The distribution pipe will be placed
at 2' below the existing ground surface to utilize the sandier lense and the total de. pth. of
the system will be 10'. Mounding may be required over the trench to proviee me
necessary 3' of protective cover.
The ground surface on the lot slopes as shown on the attached Site Plan with slight
grades from east to west. The new absorption trench will be constructed parallel to the
cont.ours of the surface .as much as. possible in conformance with Municipal
requirements. Grad ng.w~ll be accomplished to assure surfa..c.e drainage Is away fm.m
the new trench. The existing drainage pattern on the lot wi not be affected dunng
development.
Tract 9, Siefker Subdivision
May 24, 2001
Page Two
if the system is constructed in accordance with our design the following statements
apply:
1. The system, if constructed as designed, will have no adverse impact on the wells
in the area or those to be constructed in the future.
2. The system, if constructed as designed, will have no adverse impact on existing
septic systems in the area or those to be constructed in the future.
3. The system, If constructed as designed, will have no adverse impact on reserve
space, either surface or subsurface, on any lots located In the area.
4, The system, if constructed as designed, will have no adverse impact on drainage
patterns in the area, The current drainage pattern will be maintained.
Sincerely,
Michael E. Anderson, P.E.
Attachments
AVION STREET
VACANT
Existing
Well
Existing
Well
NOTE: No
with Wells in the
Existing
Septic
Tank
SCOPE OF WORK:
1. Verify
2. Remove and Dis
3.
ADEC Requirements.
4. Place New 1,000 Gall~
5. Place 2 Post Tank Ch
6. Construct
6. Regrade Ail
7. Revegetste Area As
I in Accordance With
( 3' Wide X 8' Effective
Areas.
.sting
Be,
SITE PLAN·
SCALE 1" = 30'
1,000 Gallon.
Septic Tank
63'
x 8'
TH
3' Wide
tire Depth
Trench
CE - 4381
10' Utility Easement
TRACT 9, SIEFKER SUBDIVISION
DESIGN FACTORS:
Three Bedroom Home
Perc. Rate: 30 -60 Min~lnch
Application Rate: .45 GPDISF
SYSTEM REQUIREMENTS:
Deep Trench System
1,000 Gallon Septic Tank
8' Drain Field Rock
3 Bedrooms X 150 GPD 1.45 GPDISF = 1,000 SF of Absorption Area
1,000 SFI16SF/LF = 62.5 LF Trench Length
Therefore: Construct an Absorption Trench 63' .in Length by 3' Wide Wit,h, 8' .of D_rai.n~eld
Rock Beneath the Distribution Lateral. Distribut;on Lateral to Be Placed 2 Below ~.xlsting
Ground. Total Depth of Trench to Be 10' from Existing Surface. Mound Over Trench if
Necessaw to Provide Minimum Cover of 3'.
NOTE:
TYPICAL DEEP TRENCH SECTION
(NO SCALE)
Grade Area Over Trench to Drain Away.
Minimum 6' Separation From Bedrock.
Minimum 10' Separation From Lot Line.
Minimum 4' Separation From Groundwater.
· Minimum 100' Separation From Wells in Area.
Maintain 50' Separation From Slope >25%.
Performed For: [any Motz
Legal Description: Trac! 9. Siefl(er Subdivision
3
4
9
10
11
12
13
14
17
18
21
OGIOL
SP
SM
40% Silt
Depa~ent of Health & Human Se~i~
825 L S~t, ~omge. ~ 99502~650
SOILS LOG - PERCO~ON TEST
Date
Bottom of-
Hole
Was Groundwater
Encountered?
If Yes, What Depth?
Depth to Water
After Monitoring
Date:
SLOPE SITE PLAN
North
South
Yes
16'
See Site Plan
16'
6~5/01
S
L
O
1% -2%
Reading Date Gross Net Depth To Net
Time Time Water Drop
I 5/22/01 6:25 1.125"
2 6:55 30 1.875' .75"
3 6:56 1 '
4 7'26 30 1.69" .69"
5 7:56 30 2.38" .69"
6
Perc. Rate: 44 MinJlnch Perc. Hole Diameter:. 8"
Test Run Between 5 Ft. and 6 FL
Comments: Testhole Presoaked Prior to Percolation Test. SP Layer Percolates <30 Min. per Inch.
Design System for Lower Layer or 30 to 60 Min, per Inch.
Performed By: Mike Anderson. I, Michael E Anderson Certify That This Test Was Performed
In Accordance With All State and Municipal Guidelines In Effect On This Date: 5/24/01
ON-SITE WASTEWATER DISPOSAL SYSTEM
CONSTRUCTION AND MATERIAL SPECIFICATIONS
SUBJECT: TRACT 9, SIEFKERSUBDIVISION
GENERAL:
1. The scope of this project includes the pumping,, crushing and
abandoning in place of the existing 1,000 gallon sepbc tank and the
abandonment in accordance with City and State requirements of the
existing absorption bed. In addition it includes the procurement and
placement of a new 1,000. gallon septic tank at the location shown on
the site plan. Work also ~ncludes the construction of a new 63' long X
3' wide X 8' effective depth absorption trench at the location shown.
The distribution line in the trench will be placed at 2' below the existing
ground surface. Total depth of the trench will be 10' below the existing
ground surface. All components of the septic system must be placed a
minimum of 100' from all wells in the area.
2. Con. structon sha be in. accordance with the approved s. ite plan,
des gn draw ngs Municipal Permit with any spec al provisions or
conditions, and all applicabe State and Munclpal Wastewater
Disposal Regulations.
3. The Contractor shall be responsible for obtaining all underground utility
locates and for the layout of the septic system and verification of the
location of all lot lines.
4. Unless specifically agreed otherwise, the contractor shall be
responsible for final grading areas subsequently depressed from soil
settling. Property owner shall be responsible for revegetation of
affected areas unless specifically agreed otherwise.
5. Contractors installing wastewater disposal systems must be certified
by the Municipal Department of Health and Human Services for
system installations. Owners installing their own systems must receive
prior approval from D.H.H.S. before beginning system installation.
SEPTIC TANK INSTALLATION
1. A new 1,000 gallon septic tank must be be procured from an approved
source and installed at the location shown.
2. A septic tank is to be constructed by a certified septic tank
manufacturer. Construction shall include two 4" cleanouts for pumping
access.
3. The septic tank shall be sufficiently bedded to prevent settling or
shifting of the tank.
4. All standpipes on the septic tank shall extend a minimum of 12 inches
above final grade.
5. Tanks installed without 4' of cover shall have a minimum of 2" of direct
burial insulation.
Tract 9, Siefker Subdivision
May 24, 2001
Page 2 of 3
6. A foundation cleanout shall be installed one to four feet from the
building foundation. Two cleanouts are required between the tank and
the drainfield.
7. Final grading over the tank shall be such that a positive slope exists
away from the septic tank.
DRAINFIELD CONSTRUCTION:
1. The drainfleld shall be constructed to the dimensions shown on the
design. The bottom of the trench shall be within 2" of level.
2. Distribution piping must be placed level with perforations down atop a
level bed of drainfield rock. Rock should then be placed over the pipe
to provide a minimum of 2" of cover.
3. A silt barrier or geotextile fabric must be placed between the drainfield
rock and the natural soil backfill.
4. Monitor tubes must be 4" in diameter and installed at the locations
shown on the design. The portion below ground must be perforated.
5. Contractor shall vedfy the septic tank and drainfield are a minimum
100' away from any private water wells in the area, 150' from a Class
"C" Well or 200' from any community well.
6. Direct bury insulation must be placed over the distribution system if
less than 3' of backfill depth is available. Finish grade over the trench
must be mounded to prevent settlement or depressions.
7. Grade area surrounding the absorption trenches to drain away.
8. A minimum 2' of accepting soil is required below the drainfield rock for
a 5' wide trench. Contractor shall verify this condition prior to
placement of the rock. All pockets of unacceptable materials must be
removed and replaced.
MATERIAL SPECIFICATIONS:
1. Septic tanks must be constructed by a municipally approved septic
tank manufacturer.
2. The following pipe mate. rials are approved for use in septic system
installations in the Municipality of Anchorage:
Cast Iron (perforated and solid), ASTM D3034 or P.V.C. (perforated
and solid), ASTM F810 or H.D.P.E. (perforated, but not solid) and
ASTM D2662 or A.B.S. (perforated and solid).
3. Insulation shall be at least 2" thick extruded direct burial polystyrene
(Dow Chemical Co. Styrofoam HI or equal).
4. Septic tank inlets and outlets shall be fitted with watertight couplings
(Caulder, Femco, or equal).
Tract 9, Siefker Subdivision
May 24, 2001
Page 3 of 3
5. A permeable geotextile fabric (Typar, Mirafi or equal) must be installed
between the final drain rock layer and the native soil layer.
· 6. All drain rock shall be .5" to 2.5" in diameter with less than 3% passing
the #200 sieve.
INSPECTIONS:
Municipal Ordinance requires a minimum of two inspections. These
inspections must be conducted under the supervision of a professional
engineer registered in the State of Alaska. The first inspection must be
conducted after the excavation of trenches, beds or pits and before the
installation of any gravel. A septic tank may be set in place, but may not
be backfilled.
The second inspection must be conducted after the placement of the
geotextile fabric, gravel, distribution piping, standpipes, cleanouts and
insulation. No backfill should be in place at the time of inspection.
Contractor shall provide a copy of all field survey layout and construction
notes for use in preparing the certified as-built of the completed system.
GR~TER ANCHORAGE AREA BOROP~H
HEALTH DEP.,RTMENT
327 EAGLE ST. ANCHORAGE, ALASKA 99501 279-2511
INSPECTION REPORT ON-SITE SEWAGE DISPOSAL SYSTEM
LOCATION
ADDRESS
LEGAL DESCRIPTION
PHONE__
SEPTIC TANK:
DISTANCE FROM WELL ~,5--
L,OU~D CAPACITY /~900
GALLONS.
MATERIAL ~ ~¢~. ~::~/¢~/ '~- NUMBER OF
COMPARTMENTS
INSIDE LENGTH INSIDE WIDTH
LIQUID
DEPTH ___
SEEPAGE SYSTEM:
NUMBER OF PITS
LINING MAIERIAL__
NEAREST LOT LINE
SEEPAGE PIT:
OUTSIDE DIAMETER
OR WIDTH
· DISTANCE FROM WELL
TOTAL EFFECTIVE ABSORPTION AREA (WALL AREA}
·LENGTH , DEPTH
BUILDING FOUNDATION
SQ. FT.
DISTANCE FROM WELt
NUMBER OF LINES
ABSORPTION AREA
DEPTH: TOP OF TILE lO FINISH GRADE
/WO~- / ,FOUNDAT,ON ~:g-~ '70'
, NEAREST LOT LINE
DISTANCE BETWEEN LINES TRENCH WIDTH
0 SO. ET. ,ENGTHOEEACHL,NE
/ g It DEPTH OF FILTER MATERIAL BENEATH TILg_ g ,I
TOTAL LENGTH
OF LINES /~ "7 O !
IN. TOTAL EFFECTIVE
IN. ABOVE TILE
J '~ DISTANCE FROM 4 ! WATER
WELL: TYPE '''~ ir' t [J~ ~ DEPTH ' , BUILDING FOUNDATION _SAMPLE
NEAREST ' '
LOT LINE , SEWER LINE ,~',-5~ SEPTIC SEEPAGE ~
, TANK , SYSTEM , CESSPOOL
NEAREST
OTHER
SOURCES
DIAGRAM OF SYSTEM
DISTANCES:
¥ ->d- log'
DATE
APPROVED
GREATEK ANCHORAGE AREA
HEALTH DEPARTMENT
327 Eagle St. Anchorage, Alaska 99501
~ )ROUGH;;~,~ ca~ No. ~ ~&
279-2511
SEWAGE DISPOSAL SYSTEM - APPLICATION & PERMIT
NAME OF APPLICANT
RESIDENCE ADDRESS
LEGAL DESCRIPTION.
APPLICATION TO INSTALL: SEPTIC TANK
TO SERVE THE FOLLOWING FACILITY
FINANCED THROUGH
~TEST RESULTS
MAILING ADDRESS. lgq$ cH, , PHONE NO,
TO BE INSTALl_ED BY.
ANTICIPATED DATE OF COMPLETION
BELOW TO BE FILLED OUT BY HEALTH DEPARTMENT
THIS IS TO SERVE AS qw~-.~, [(.OR.~, ,PERMITTO INSTALLA
AS DF. SCRIBED BELOW. SIZE OF UNIT TO BE SERVED
,SEPTIC TANK SIZE ! 0 C~) TYPE SEEPA
DIA'
OF SYSTEM
DISTANCES:
--:TO BE.
Loca~-c._ o
~o0~
I certify that I am familiar with the requirements of Greater Anchorage Area Borough Ordinance No. 2~68 and that the
above described system is in accordance with said code.
DATE APPLICANTS SIGNATURE
6REATER ANCHORAGE AREA BOROUGH
HEALTH DEPARTMENT
327 EAGLE STREET
ANCHORAGE~ ALASKA99501
CASE
Perfo~'med For, '/~/,.~ ,/~/~,/~/~c ..... ~ate Pem~o~med~~ /~.... .
This Form Reports a: Soils Log~j]~.~,.._--Pe~a=on Test~
Depth
Feet So~1 Chapacteristics
Was Ground Watem Encountered?__~
If Yes~ At ,,,'at Depth
·
Proposed Installation: Seepage Pit
G~oss Time
Net Time
Location Sketch
Depth To H20
Drain Field
Net Dz~op
Depth Of Inlet..~,,..__~__,__._...,,_Depth T-----~Bot'"~--tom Of:~it Om 'J!'lJench
COMe, ON'rS:
Test Performed By:
Data Certified By: Date:
REQUEST FOR APPROVAL OF
V ' I INDIVIDUAL SEWAGE AND WATER FACILITIES
--, (Fill ou~ in Trip.licate)
a. Bactemia~, .......
b. Detergent
data:
a. Type -)(f , . ~ _~ ,
c. Casing Size .
Distance from well to clOsest existing or proposed:
1, Sewer line ,,-~),CJ~
2, Septic tank [~.:{ .
4, Cesspool~ ....... ,
5. Property Line ,9~ /.
6. Other sources of possible contamination, i,e., creeks, lakes,
houses, barn~ drainage ditcl~, etc, . :. .
Sewage disposal system,
a. Age of system_ : I ~ ~' 2 ·
b, Septic tank capacity ~n gallons ~d~'~'/--~:) ,
.
c, Name of septic tank manufactu~e~ ~t::%' (/~~(' '
1. If "home made" show diagram on reverse side of this fomm,
dj'
Disposal field or seepage pit size and
1, Distance to property., line to house foundation
e. PePcolatio~ Te~th~esults
,.~ ~ufi~ Percolation Test performed by ....................... ........... .
the reverse.side of this fo~'m to show diagram. Diagram should fn¢lude
following info~matlonl p~ope~ty lines;.w~ll location, house locatlon~
'l~.p~ic tank location, disposal aroa loeation~ location of percolation tost~
a~ di~ection of ground slope,
The }~f~or~ation on this form is ~ue and cop~ect to the best of my knowledge.
~O,, BE FILLED ,OUT. , B,Y, H, EA,LTH. . ,DE,PART('!ENT, ,. ,,, ,PErSONiFy.L, .. _
~'he above described sanltamy facilities ama hereby epproved~ subject to the
Conditions: /~2~i
The above described sanitary facilities are dis~3pp~oved rom the following
Peaso~]s:
"~ .Appmoval i~/val~d fom one year followin~ the date of approval.
~' CPJ:cw
METROPOLIT -fl N
533 W. 8TH AVENUE
ANCHORAGE, ALASKA 99501
279-7200
Health Center
Division of Public Health
State of Alaska
327 Eagle St
Anchorage~ Alaska
June 3, 1970
HOMES
ACREAGE
INCOME PRO Y.E. CTI O N
FINANCING
Attention: Mrs. Nelson
Dear Mrs. N~lson:
Attached is a key to property we are selling and upon which
we understand you have previously issued an approval of sanitary
services. As ~Te understand you will need to take a new water
ssmple, we are enclosing the key together with a copy of an asbuilt
survey of the subject property. We would appreciate receiving an
approval of the w~ter and the sewage system at this address; if
necessary you may forward the approval directly to the Veterans
Administration with the notation that this is in reference to the
Larry Motz loan application.
DT/hta
'/7,truly~ffTrs '
"""' .~ / % ~:,//,-F~,'~'~4"'~'~ ./// ']~"I'7 REQUES? FOR AP?ROVAL OF ~ .d~j!/f~/([~.~L,;~/~-,~..~ a"7' .... _ --
c. Casin~ Siz~: ~ll
d. Distance from well to closest exlstin~ oP pPopose~:
,. 3, $eepa[~e Area / .
4. Cesspool' ,
5. Property Line
6. Other sources of possible contamination, i,e., creeks, lakes,
houses, baPn~ drainage ditch, etc.. ...........................
7. Sewage disposal syste~l.
l, If "home made" ~how dia~r.~m on reverse ~ide of ~his fo~m,
~; Disposal field or seepage pi~ size and ~yp~C.~_a ~
l, Dim~ance ~o p~op~r~y .lim~ ~o house
Percolation Test Tesults
f. Percolation Test performed by
~'"~. Use the reverse .side of this form to show diagram. Diagram should include
.-[i-the following Jnformatior,: pFoperty lines~ .well location, house location,
,~e~ptlc tank location, disposal, area location, location of percolation test,
aad, direction of g'oound slope.
9. The 5~,-~,-~at~or~ on this form is true anal correct to the best of my knowledge.
Date Signed
TO B._~E_FILLED OU'? BY HEALTH DEPART~.!ENT PERSONNEL
~-~T~e~... above, described sanitary facilities are hereby approved, ~ubjec~ to the
follow,.n? cor~d~'fons: - -
Conditior~s:
The above described sanitary facilities are disapproved for the followin~
reaso~
Approval is valid for one year following the date of approval.
CPJ:cw