HomeMy WebLinkAboutLot 07AADDN
GREA.,:R ANCHORAGE AREA BOR~_,GH
Department of Environmental Quality
3330 C Street
Anchorage, Alaska 99503
INSPECTION REPORT ON-SITE SEWAGE DISPOSAL SYSTEM
NAM E ~-~~-
LOCATION
MAILING ADDRESS ~ ~'~)~v3~ ~::~, ~ PHONE
LEGAL OESCR,PTION .Z~r' q ~Ib J A~ ~_~I- .~'14
SEPTIC TANK.'
DISTANCE ?j~)
FROM WELL
INSIDE LENGTH
.~,~ ~:~ NUMBER OF
MANUFACTURER MATERIAL ,COMPARTMENTS
INSIDE WIDTH
LIQUID DEPTH
LIQUID C APAC I TY/~)-OGA LLON S.
TILE DRAIN FIELD:
DISTANCE FROM WELL
NUMBER OF LINES
FOUNDATION 20 ~' NEAREST LOT LINE /~/ I TOTALoF LINEsLENGT"~'~'3" /
O,STANCE BETWEEN L,NES 4'//~ TRENC. W,OT.~C,N. TOTAL EFFECT,VE
ABSORPTION AREA /~D SQ. FT. LENGTH OF EACH LINE
DEPTH
OF
FILTER
DEPTH: TOP OF TILE TO FINISH GRADE ~t
I
MATERIAL BENEATH TILE
~]'1 'I~ItlABOVE TILE
IN.
WELL..
TYPE
BUILDING
FOUNDATION
CESSPOOL
APPROVED
CONSTRUCTION
NEAREST NEAREST
. LOT LINE , SEWER LINE
· OTHER SOURCES
DISAPPROVED REMARKS
DEPTH
SEPTIC SEEPAGE
TANK , SYSTEM
DISTANCE FROM:
DISTANCES:
INSTALLED BY: ~. ~
!
SEWER LINE DEPTH:
PIPE MATERIAL:-~'~'''
LOT SLOPE: ~
REMARKS: ?0' Z~,~,~; J:~,~
Form EQ-032
DIAGRAM OF SYSTEM
/vt'
GrEA~R ANCHORAGE AREA BOR~'~gh
SEWAGE DISPOSAl. SYSTEM ~ APPLICATION AND PERMIT
,o,L TEET .ESULTS 2.';'0
DRAIN FIELD
OTHER
THIS PERMIT IS riOT VALID WITHOUT BOIL. T~ST
FINAL INSPECTION: 24 HOUR NOTICE REQUIRED. BACKFILLING OF ANY SYSTEM WITHOUT FINAL INSPECTION BY THE
DEPARTMENT OF ENVIRONMENTAL QUALITY AUTHORITY WILL BE SUBJECT TO PROSECUTION.
FOUNDATION TO SEEPAGE PIT
SEPTIC TANK TO SEEPAGE PIT WALL ~'/~
DRAIN FIELD
1
WATER MAIN TO SEPTIC TANK
.. DRA"N F~ELO /~ ~
· SEEeAOE P*T /~ /
,,'/~o ~ ,~.A,N ,,EKD /,~ /
GRAVEL, laACKFIU.
DIAGRAM OF SYSTEM
",'TE '¢--g~--23-- AP.L,CA.T'S ..O.AT,,.~.-y' .... ' .
.0 8 E GEO1 ,~CHNICAL ~8 DEVELL..'MENT CO.
Ru~ell Oyater
694-2774
Soils ~ Foundations
Performed for:
Legal Description:
Depth (feet)
1
2
4
5
6
7
Box 90, Davis St., Eagle River, Alaska 99S77
694.2774 or 688-2280
$0~r~- LoG Land Devefopmen!
Name: #~1 z:r-¢ ~ ~ ~/~ ~/~¢~ Tel. No.
1]
~;9~1 (;haractertsttcs
!
7: 4':
7;~-:
Ground Water Encountered: Yes
Proposed ~nstalletton: Seepage Pit
Coa~ents:
NO
,yes, what depth
SEPTIC TANK SURVIVAL SURVEY
This survey attempts to measure the operating success of septic tank sewag(.
disposal systems in the surveyed area.
A septic tank is considered to have failed if sewage daylights (appears) on the
surface of the ground. This indicates that the drain field is not absorbing the
sewage properly. A failure can either be complete, meaning the sewage continues
to accumulate on the surface for a long period of .time, or periodic, meaning failure
occurs periodically followed by reabsorption. In addition, having to pump a
system more than Once a year also constitutes a failure.
1. Location of home Z07' 7
2. Number of bedrooms
3. Is the existing system the original system?
Yes ~ No Doesn't Know
4.- Do you know in what year the existing system was installed?
Year ~4-~ Doesn't Know
5. Has the existing system ever failed? Yes No
6. If yes, in what year and season did it initially fail?
Year Season Doesn't Know
'7. If yes, was any corrective action taken? Yes No
8. If yes, what was done?
a. Septic tank pumped
b. New trench or drain field dug
c. Other
9.-Has it failed since that time? Yes
10. At what time of year does it generally fail
or winter)
ll. How many times has the system been pumped?
No
(i.e., spring, summer, fall