Loading...
HomeMy WebLinkAboutEAGLE CREST #1 TR A LT 10 ' ,, Municipality of Anchorage Page / DEPARTMENT OF HEALTH AND HUMAN SERVICES ENVIRONMENTAL SERVICES DIVISION P.O. Box 196650 · Anchorage. Alaska 99519-6650 · Telephone: 343-4744 On-Sile Waslewater Disposal System and/or Well Inspection Report Permit Number: ,.~ ~'00,.5'O PID Number: N.~.: t/~EL~ ~U~ ~ WaslewaterSystem: ~New DUpgrade A~,,,,: /~u ~,~r~c ~. ABSORPTION FIELD ,.o..:~(~./~/~ I'°'~eed's'': ODeepTrenc. DShallowT,ench =Bed DMound DOlher LEGAL DESCRIPTION '-'"' I"'"0': I .,,, .dd..~e orIgln~r~.: Gr..I length: WELL: ~ New ~ Upgrade ~ // F~. / ~EPARATION DISTANCES a septic ~ Holding a S.T.E.P. Sudace w.t.r ~ ,/~5 /o~ LI~STATION Remarks: ~'~ ~Z~ ~ ~,~%~[~ BENCH MARK Inspections pedormeu n~,-r-,- m~ t~ .... ~ates: lSI Deparlment of Heallhand Human ~e~mes approvm Reviewed and approved by: ~~ ~/~'~ Date: ~' PERI, lIT N0. SWgS0050 PAOE 2 OF 2 Municipoli~ oR Anchoreme DEPARTMENT OF HEA~THAND HUM'AN SERVICES ENVIRONMENTAL SERVICES DIVISION · P.D. ]~ox 196650 ~._Anchor~ge, A[nskc~ 99519-6650 · Tetephone, 343-4744 ON-SITE WASTEWATER DISPOSAL SYSTEM AND/OR WELL INSPECTION REPORT LOT 10, TRACT A, EAGLE CREST P.i.D. NO. 050--503--01 A B C rCO - 20.5' 7.0' ST1 56.0' 12.5' - 5T2 50.0' 9.0' - ~IT1 59.5' 10.5' - ~T2 25,5' 62,0' - ~IH 49,0' 9.0' - CITATION ROAJ] l0 NEW 1250 GAl.,. S.T.E.P. TANK LOT9 90' t~ a~. Dg.8' }dTI_.JUTI . 96.8'. J IMT2 = 100.4 //FINAL GRADE N.T.S. ~ = 92.4' · NO WATER FOUND 85.3' B.O.tl. ~H~' SAND DA APPROV£~ 825 "L" Street Rick Mystrorn, P.O. Box 196650 Anchorage, Alaska 99519-6650 Mayor http://www.cLanchorage.ak.us December 9, 1998 Robert C. Cowan S&S Engineering 17034 Eagle River Loop Road, Suuite 204 Eagle River, Alaska 99577 Subject: Waiver Request for Eagle Crest #1 Lot 10, Tract A Waiver Request #WR980058 Parcel ID #050 303 01 Permit #SW980050 Dear Mr. Cowan: Your request for a waiver of the required 10 feet horizontal separation from the on-site wastewater disposal system to propertyline has been approved. The approved separation distance is 1.0 foot. This waiver approval applies to the existing on-site wastewater disposal system to property line separation only. Any future upgrade to the on-site wastewater disposal system will require all separation distances be met or another approval from this department. If there are any further concerns or questions regarding this waiver, please call our office at 343-4744. Sincerely, Donna C. Mears ~ Civil Engineer On-Site Water Quality Program MUNICIPALITY OF ANCHORAGE Department of Health and Human Services On-site Services Section Waiver Review Worksheet WR#I~q~ PID# 050-303-01 HA% Date Received: Sept.:11, 1998 Legal Description: Lot 10 Tract A Eagle Crest Subdivision Engineer: Robert C. Cowan, P.E., S & S Engineerin~ 17034 Eagle River Loop Road, Suite 204, Ea~le River, Alaska Applicant: Joanne Unsworth ( Harley Sudsbury) Waiver Requested: I foot Permit # SW980050 99577 Lot line waiver from the leachfield to the properly'line of Criteria: 1. Geology: Points: This waiver was orginially A. Water Table applied for in March, B. Soil Sorption however, ,the fees were not C. Permeability paid or was it reviewed until the as-builts came D. Water Table Gradient in for an "amefided" waiver E. Horizontal Separation of the original request. Fees have been paid TOTAL: See below. LJM 2. Special Conditions: 3. Other: Waiver is Granted: List Conditions or Reasons Waiver is NOT Granted: for above: Date: By: Name of Reviewer Rec #: 04054/5190 Amount: $ 115.00 Date Paid: Sept ll, 19~8 491 Willow Street · Wasilla, Alaska 99654 Piton=# (907) 373-3893 - Fax# 373-3594 RECEIVED DEC '1 1998 Municlpalit~ of Anchorage Oept. Health & Humen Services ROBERT C. COWAN. R E. ROBERTA. SHAFER, RE. September 9, 1998 CIVIL ENGINEERS SOIL TEST (907) 694-2979 FAX (907) 694-121 t Municipality of Anchorage DEPARTMENT OF HEALTH AND HUMAN SERVICES 825 L Street P.O. Box 196650 Anchorage, Alaska 99519-6650 REFERENCE: Lot 10, Tract A, Eagle Crest Subdivision #1 Mumc~pa~'~ ~,,,man Services Dept. Hearth Request you grant a modification to the previously requested waiver for the separation distance between the leachfield and the property line for the referenced property at 1 foot. If we may be of further service please contact us. Sincerely, Robert C. Cowan, P.E. RCC/mg Enclosure 17034 NORTH EAGLE RIVER LOOP · SUITE 204 * EAGLE RNER. ALASKA 99577 q$ I[ PAGE 1 OF 1 MUNICIPALITY OF ANCHORAGE DEPARTMENT OF HEALTH AND HUMAN SERVICES P.O. BOX 196650, 825 "L" STREET, ROOM 502 ANCHORAGE, ALASKA 99519-6650 ON-SITE WASTEWATER DISPOSAL SYSTEM PERMIT PERMIT NUMBER:SW980050 DESIGN ENGINEER:S & S ENGINEERING 'OWNER NAME:UNSWORTH JOANNE R OWNER ADDRESS:10335 CREST VIEW LN EAGLE RIVER, ALASKA 99577 DATE ISSUED: 4/01/98 EXPIRATION DATE: 4/01/99 PARCEL ID:05030301 LEGAL DESCRIPTION: EAGLE CREST TR ALT 10 LOT SIZE: 11075 (SQ. FT.) NUMBER OF BEDROOMS: 3 THIS PERMIT: 3 THIS PERMIT IS FOR THE CONSTRUCTION OF: DISPOSAL FIELD /SEPTIC TANK SYSTEM ALL CONSTRUCTION MUST BE IN ACCORDANCE WITH: 1. THE ATTACHED APPROVED DESIGN. 2. ALL REQUIREMENTS SPECIFIED IN ANCHORAGE MUNICIPAL CODE CHAPTERS 15.55 AND 15.65 AND THE STATE OF ALASKA WASTEWATER DISPOSAL REGULATIONS (18AAC72) AND DRINKING WATER REGULATIONS (18AAC80). 3. THE ENGINEER MUST NOTIFY DHHS AT LEAST 2 HOURS PRIOR TO EACH INSPECTION. PROVIDE NOTIFICATION BY CALLING 343-4744 ( 24 HOURS } (NOT REQUIRED FOR WELL ONLY PERMIT) 4. FROM OCTOBER 15 TO APRIL 15 A SUBSURFACE SOIL ABSORPTION SYSTEM UNDER CONSTRUCTION DURING FREEZING WEATHER MUST BE EITHER: A. OPENED AND CLOSED ON THE SAME DAY B. COVERED, SEALED AND HEATED TO PREVENT FREEZING 5. THE FOLLOWING SPECIAL PROVISIONS. SPECIAL PROVISIONS RECEIVED BY: ISSUED BY:~ DATS: / DAT .:4 --/-- 9'8 March 23, 1998 ROBERT C. COWAN, P.E. CML ENGINEERS (907) 694-2979 FAX (907) 694-1211 MUNICIPALITY OF ANCHORAGE Department of Health and Human Services P.O. Box 196650 Anchorage, AK. 99519 REFERENCE: Lot 10, Tract A, Ea ,gle Crest Subdivision #1 Request you issue a permit to install a septic system to serve the proposed three bedroom house on the referenced property. Also, request you issue a 5 foot lot line waiver from the proposed drainfield to the West property line. Two test holes were excavated and percolation tests were performed. The approximate location of the test holes are located on the attached site plan. At the time of excavation no groundwater was encountered in the test holes. After seven day groundwater monitoring, the monitoring tubes were checked and found to be dry. This property has enough area for a future septic upgrade which can be seen on the attached site plan. We do not anticipate any adverse effects on neighboring wells, septic systems or drainage patterns by the installation of the proposed septic system. If you require additional information, please contact us. Sincerely, RCC/jlm Enclosure 17034 NORTH EAGLE RIVER LOOP · SUffE 204 · EAGLE RIVER. ALASKA 99577  ~ LOT 10, TRACT A, EAGLE CREST S/D #1 S.R.J. J.L.M. 05-25-98 2 OF 2 ~., ~/ ./ .../ , ,~.~,/~ '.,,.,~11,,I/~.~.~..~ ~ri.g CITATION ROAD ,~~~ ~ ~ % .~ ~ ,~t, ~ ~ ~ ~ I I I I I I LOT 10 ,M~,~ ........... I I I I I DESIGN CRITERIA: ~ co.,~o. ~ .[~u..[o ,o BDRM 450 I I I I I ~ wo~ so s: 45o/~ = 45o se.~. ~Ee'~. ~m ~/ / ~ ~ ~ --L--.~AT SI~ ~ ADD 2' SAND FILTER ,k 0.5' EFFECTIVE 5' WIDE PROPOSED GRAVEL 101' LONG (90' + 12~) TO MAIN DRIVEWAY ~°'~ ~ PROPOSED 1000 GAL. %SERVICE LINE 0 ~ ~ SEPTIC TANK ~~: ~ 0 ~ ~ ~ ~ LOT 9 ~'~ ~ ALT. SIT~ CRITERIA: I ~ ~ ~ ~ 0.5' EFFECTIVE I I 75' LONG J j I [ ~PROPOSED DRAINFIELD SHANE A. HOLT CUENT .~. 10' UTILITY EASEMENT A~ POR~ONS OF SY~EM ,.~~ W~H ~SS ~ 3.5' OF COVER ~QUIRE INSU~TION.  ~ LOT 10, TRACT A, EAGLE CREST _.. r.. S.R.J. J.LM. 3-23-98 I SH*N[ A. HOLT I DESIGN CRITERIA: ~ ATION DRIVE ~o~. 5 BDRM = 450 OPD T m~%.__~ -- sol~ = ~.2 ~P,/Se.F~. ~, SITE DRAINFIELD CRITERIA: x~ ~ ADD 2' SAND FILTER mPROPOSEO 1000 GAL, II IIO~ull ~ o.~. ~.~c.,v~ ~.T,C T..~ ~ ~ ~ ~'-' ~7'- ~= tO~ 1 ~ 0 I ill I , ~ DRAINFIELD ........... ~ --~' I ~ ,~ ~ I m~ ~ ..................... ~" LOT 1 LOT 12 i ~ , ~. LOT 11 LOT 12 . Exii~ ~1 ~ ~ CU[NT COVER ~U~ ~SU~TIO~ ~ Municipality of Anchorage DEPARTMENT OF HEALTH & HUMAN SERVICES 825 'L" Street. Anchorage, Alaska 99502-0650 SOILS LOG ~ PERCOLATION TEST PERFORMED FOR: LEGAL DESCRIPTION: 2 3 4- 5- 6- 7- 8- 9- 10- 11 12 13 14 15 16. 17- 18- 19- 20- ~-.o.H A% · 'WAS GROUND WATER ENCOUNTERED? IF YES, AT WHAT DEPTH? Township, Range, Section: - ~p~ I~ Wiler ~J~r M~itming? 01~ SLOPE SITE PLAN Gross Net Depth to Net Reading Date Time Time Water Drop PERCOLATION RATE ~7 J ImJnute~nch) PERC HOLE DIAMETER TEST RUN BETWEEN "'7 FT AND ~ FT 72-008 (Rev. 4/85) PERFORMED FOR: LEGAL DESCRIPTION: 1 2 3 4' 5 6 7 8 9- 10- 11 13- 14- 15- 16 17 18 19 2O COMMENTS Municipality of Anchorage DEPARTMENT OF HEALTH & HUMAN SERVICES 825 'L" Street, Anchorage, Alaska 99502-0650 SOILS LOG -- PERCOLATION TEST L.o-r Io~ 'r'~.kc-r At i -~ ~ Rog~.T ~ COW^. DATE PERFORM'; 'J "." ' Township, Range, Section: WAS GROUND WATER ENCOUNTERED? IF YES, AT WHAT -- DEPTH? ~- pO E Dei~h to Wale~ After / / Idonitm'ing? Of,.~ I~1~ ~ ELOPE SITE PLAN Gross Net De~th to Net Reading Date Time Time Water Drop PERCOLATION RATE ~' ~ (m,r*utes,'mch) PERC HOLE DIAMETER TEST RUN BETWEEN "~ % ~ t FT AND FT ~~UIDELINES IN EFFECT ON THIS DATE. DATE; ACCORDANCE WITH THA)' THIS T~ST WAS PERFORMED IN Municipality el Anchorage DEPARTMENT OF HEALTH & HUMAN SERVICES 825 'L' Street. Anchorage, Alaska 99502-0650 SOILS LOG -- PERCOLATION TEST PERFORMED FOR: 1 O~6~ttC's 2 3 4 5 6 7 8 9- 10- I1 13- 14- 15- 16- 17- 18- 19- 20- Township, Range. Section: SLOPE WAS GROUND WATER.f~*/~ ENCOUNTERED? IF YES. AT WHAT ~ ~) DEPTH? ~, De~h 1o Wale[ After Monitoring? Iflale: SITE PLAN Gross Net Depth to Net Reading Date Time Time Water Drop : ~ ~ i~,~ 5 ~" ~" .. ~ ,/ i~,,~ 6 ,, ~/~,, PERCOLATION RATE t'~"~Y~ (minutes/inch) PERC HOLE DIAMETER __ 7EST RUN BETWEEN ~ FT AND ~7 FT COMMENTS PERFORMED BY; ~.7_n34. E_~;!-~ R.fy_-.-* t__~_~ ~_~_.~_ H-'. ~ I CERTIFY THAT T~JlS T~EST WAS PERFORMED IN ACCORDANCE w~rHt~t ~i~,'r ~IJ~i~AL O UiDE LIN ES iN E F F ECT ON THIS DAT E, DATE:' ~ //O/q~ 72-008 IRev. 4t85) ROBERT C. COWAN, P.E. CML ENGINEERS ON-SITE WASTEWATER DISPOSAL SYSTEM CONSTRUCTION PRACTICES and MATERIAL SPECIFICATIONS (907) 694-2979 FAX (9O7) 694-1211 REFERENCE: Lot 10, Tract A, Eagle Crest Subdivision #1 March 23, 1998 GENERAL: Thc scope of this project includes the installation of a 1000 gallon septic tank and a five foot wide drainficld to serve the proposed three bedroom residence or thc referenced property. Construction shall be in accordance with the approved site plan and design drawings, Municipal permit with any special provisions or conditions, and all applicable State and Municipal Wastewater Disposal Regulations. Thc contractor shall be responsible for obtaining any necessary underground utility locates. Unless specifically agreed otherwise, the property owner shall be responsible for final grading areas subsequently depressed from soil settling. On all leachfield mound systems, the property owner shall be responsible for ensuring a satisfactory vegetation growth over the mounded area. Contractors installing wastewater disposal systems must be certified by the Municipal Health Department for system installations. Owners installing their own systems must also receive prior approval from the Municipal Health Department. SEPTIC TANK INSTALLATION: 1. A septic tank is to be constructed by a certified septic tank manufacturer. Construction shall include two 4" clcanouts for pumping access. 2. The septic tank shall be sufficiently bedded to prevent settling or shifting of the tank. 3. All standpipes on thc septic tank shall extend a minimum of 12 inches above final grade. 17034 NORTH EAGLE RIVER LOOP · SUffE 204 · EAGLE RIVER. ALASKA 99577 Page Two Lot 10, Tract A, Eagle Crest Subdivision gl March 23, 1998 4. Septic tanks installed with less than 4 ft. ofcover shall be insulated. A foundation cleanout shall be installed one to four feet from the building foundation. In the line between the tank and the leachfield there shall be two adjacent cleanouts (unless an effluent pumping system exists within the septic tank). These cleanouts shall be located on undisturbed soil not more than 10 ft. from the tank. The first cleanout, in line, shall be to clean toward the leachfield. The second cleanout shall be to clean toward the septic tank. 'Final grading over the septic tank shall be such that a positive slope exists away from the septic tank. ABSORPTION TRENCH/DRAINFIELD INSTALLATION: Excavate the proposed trench to the dimensions shown on the design. The bottom of the excavation shall be within 2 inches of level. If the sidewalls of the excavation become smeared, they must be raked or scratched (raffed-up) before gravel (sewer rock) placement. Once the gravel is installed, the distribution pipe is to be installed level with the perforations faced downward. Gravel is then to be placed over the distribution pipe to provide a minimum of 2 inches of cover over the pipe. A silt barrier must be installed between the final gravel layer and the native soil backfill. Ensure the silt barrier covers the entire gravel surface before placing backfill. Monitor tubes shall be of four {4) inch diameter, installed approximately in the locations shown on the design, and extend a minimum of 12 inches above final grade. The portion of the monitoring tube extending through the gravel shall be perforated from the bottom of the trench to the invert ofthe distribution pipe. This is equivalent to the effective depth of the gravel as noted on the design. Backfill over the final gravel layer must not be less than twenty-four (24) inches. Insulation must be installed when the backfill depth is less than thirty-six (36) inches. The finish grade over the trench must be mounded to prevent the formation of a depression after settling. MINIMUM MATERIAL SPECIFICATIONS: 1. Any septic tank proposed for installation must be constructed by a Municipally approved septic tank manufacturer. Page Three Lot 10, Tract A, Eagle Crest Subdivision #1 March 23, 1998 2. The following pipe materials are approved for use in septic system installations in the Municipality of Anchorage: Twe of Pine perforated ~;olid Cast Iron ASTM D3034 (PVC) ASTM FS10 (HDPE) ASTM D2662 (ABS) Yes Yes Yes Yes Yes No Yes Yes Use of a type of pipe other than listed above must be approved by the inspecting engineer. Insulation shall be at least 2" thick extruded direct burial polystyrene (Dow Chemical Company Styrofoam HI or equal). Septic tank inlets and outlets shall be fitted with watertight couplings (Caulder, Femco, or equal). A permeable nontoxic silt barrier (Typar 3401, Mirafi 140N, or equal) must be installed between the final leachfield gravel layer and the native soil backfill. All leachfield gravel (sewer rock) shall be 0.5"-2.5" screened gravel with less than 3% passing the #200 sieve. When sand is being used as a filter material, its gradation specifications must conform to current M.O.A. or D.E.C. requirements, which ever applies. INSPECTIONS: Typically there will be a minimum of three (3) inspections required during the installation of the wastewater disposal system. These inspections will occur as follows: The first inspection must be conducted after the excavation of ditches, pits, trenches, or beds and before the installation of any gravel. A septic tank may be set in place, but may not be backfilled before this inspection. The second inspection must be conducted after the placement of the silt barrier, gravel, distribution lines, standpipes, cleanouts, and insulation, but before the placement of any other backfill. 3. The final inspection is to occur upon final grading ofthe property. Page Four Lot 10, Tract A, Eagle Crest Subdivision #1 March 23, 1998 Often there will be more than these 3 inspections required. Especially with the installation of multiple trenches, sand filters, pressurized distribution systems, etc. Thus, the inspecting engineer is to be contacted at least 24 hours prior to the start of construction. If necessary, a pre-construction meeting will take place on-site. The inspecting engineer will not coordinate, direct or control in any way the contractors activities. The owner shall contract with the contractor to perform the work outlined in these specifications and plans and in accordance with the attached M.O.A. permit. There will be no contractual arrangement existing between the contractor and S & S Engineering. S & S Engineering shall be the owner's representative and will inspect the work as stated above to document the contractors activities. Final acceptance of the contractors work rests with the owner and the M.O.A. S & S Engineering shall have no liability to the owner or to others for acts or omissions ofthe contractor or any other persons performing work on this project or the failure of the contractor to carry out the work in accordance with these construction documents. S & S Engineefing's inspecting engineer will not be responsible for the construction means, methods, techniques, sequence, procedures or the safety precautions incident to this project. CONTRACTOIUOWNER