Loading...
HomeMy WebLinkAboutEAGLE CREST #1 TR B LT 34 Municipality of Anchorage Page J of DEPARTMENT OF HEALTH AND HUMAN SERVICES ENVIRONMENTAL SERVICES DIVISION : P.O. Box 196650 · Anchorage, Alaska 99519-6650 · Telephone: 343-4744 On-Site Wastewater Disposal System and/or Well Inspection Report Permit Number: ~\ x']clL~ t"xS<l:~ PID Number: Name: ~/Uo~E~,~ ~O J~,~ ~.., ~,~, WastewaterSystem: D New ~ Upgrade ~,~ ABSORPTION FIELD Phone: ~--~O ~ Deep Trench ~ShallowTrench DBed ~Mound DOther Lot: ~ ~: ~K~c~ ~ Su~iv~ion:~bE ~T ~p~pi~f~odginalgmde:~. Township: I Range: I ~tion: Fill Idd~ a~ve o~ginal g~de: Grovel length: WELL: ~t~T~ New ~ Upg Gmvelwldtm SEPARATION DISTANCES ~ Septic ~ Holding a S.T.E.P. From Tink F~ld ;tltl~ Tank ~tU~ A~ ~ Sudace Water IOO'~ loc'+ -- -- - LIFTSTATION Foundation ~' ~' -- -- -- 'Pump °n' ~e' '~~'eve"t: I Hig~ water"a~ at: Cu~ain Drain Remarks: . BENCH MARK ENGI~L Inspections pedormed bt7034 Earle m"r [°°P "~' He'~ates: 1st "' =°' ~ ~ Department of Health and Human Se~ices ap~ Pea'mit No.' SW960053 2 2 Page .of Municipality of Anchorage DEPARTMENT OF HEALTH AND HUMAN SERVICES ENVIRONMENTAL SERVICES DIVISION P.O. Box 196650 · Anchorage, Alaska 99519-6650 · Telephone: 343-4744 On-Site Wastewater Disposal System and/or Well Inspection Report Legal Description:LOT 54, TRACT B, EAGLE CREST S/D PIDNo.:05029116 / STI ST2 COl Cl~3 NE~ SEP TAN ( 88.9 86.9~-'"- I A82,9' ;0 GROUND WA'I Ell 16~5, l 4-18-98 SI1 31' I ~l · ~ m~ CO: 71' I 90' ~ ~ C01 43.2' I 71' Ja ~ [~ . MI1 70.~ { 88.5' ~ ~ ~. MT2 68.5' 78' ~,~.. ~ ~..~ MUNICIPALITY OF ANCHORAGE DEPARTMENT OF HEALTH AND HUMAN SERVICES P.O. BOX 196650, 825 "L" STREET, ROOM 502 ANCHORAGE, ALASKA 99519-6650 ON-SITE WASTEWATER DISPOSAL SYSTEM (UPGRADE) PAGE 1 OF 1 PERMIT PERMIT NUMBER:SW960053 DESIGN ENGINEER:S & S ENGINEERING OWNER NAME:WYNN DAVID C & ROBYN OWNER ADDRESS:19057 FIRST ST EAGLE RIVER, ALASKA 99577 DATE ISSUED: 4/19/96 EXPIRATION DATE: 4/19/97 PARCEL ID:05029116 LEGAL DESCRIPTION: EAGLE CREST TR BLT 34 LOT SIZE: 17820 (SQ. FT.) NUMBER OF BEDROOMS: 3 THIS PERMIT: 3 THIS PERMIT IS FOR THE CONSTRUCTION OF: DISPOSAL FIELD /SEPTIC TANK SYSTEM ALL CONSTRUCTION MUST BE IN ACCORDANCE WITH: 1. THE ATTACHED APPROVED DESIGN. 2. ALL REQUIREMENTS SPECIFIED IN ANCHORAGE MUNICIPAL CODE CHAPTERS 15.55 AND 15.65 AND THE STATE OF ALASKA WASTEWATER DISPOSAL REGULATIONS (18AAC72) AND DRINKING WATER REGULATIONS (18AAC80). 3. THE ENGINEER MUST NOTIFY DHHS AT LEAST 2 HOURS PRIOR TO EACH INSPECTION. PROVIDE NOTIFICATION BY CALLING 343-4744 ( 24 HOURS ) (NOT REQUIRED FOR WELL ONLY PERMIT) 4. FROM OCTOBER 15 TO APRIL 15 A SUBSURFACE SOIL ABSORPTION SYSTEM UNDER CONSTRUCTION DURING FREEZING WEATHER MUST BE EITHER: A. OPENED AND CLOSED ON THE SAME DAY B. COVERED, SEALED AND HEATED TO PREVENT FREEZING 5. THE FOLLOWING SPECIAL PROVISIONS. SPECIAL PROVISIONS: Mmxicipali ' of Anchoragc Department of Health and Human Services 825 "L" Street Rick Mystrom.P.O. Box 196650 Anchorage. Alaska 99519-6650 Mayor April 24, 1996 Robert C. Cowart, P.E. $ & S Engineering 17034 Eagle River Loop Road Suite 204 Eagle River, Alaska 99577 Subject; Waiver Request for Lot 34 Tract B Eagle Crest Subdivision Waiver Request #WR960015, PID #050-291-16, SW960053 Dear Mr. Cowan: Your request for waiver of the required 10 foot separation between an on-site wastewater disposal field and the west property line has been approved. The waived distance is 1 foot. This approval applies to the existing on-site wastewater disposal field and lot line separation only. Any future upgrade to the on-site wastewater disposal system will require all separations be met or another approval from this department. If there are any questions, please call this office at 343-4744. Sincerely, Civil Engineer On-site Services DJR/ljm:Wynn Waiver MUNICIPALITY OF ANCHORAGE Department of Health and Human Services On-site Services Section Waiver Review Worksheet HA# WR# WR960015 PID# 050-291-16 Date Received: April 19, 1996 Legal Description: Lot 34 Tract B Eagle Crest Engineer: Robert C. Cowan, P.E., S & S Engineering Permit #SW960053 17034 Eagle River Loop Road, Suite 204, Eagle River 99577 Applicant: David C. Wynn Waiver Requested: Lot waiver from absorption trenches to property line of 1 foot Criteria: 1. Geology: Points: A. Water Table ~ B. Soil Sorption ~ ~ ~.~ C. Permeability ('% ro ~ D. Water Table Gradient E. Horizontal Separation TOTAL: Special Conditions: 3. Other: Waiver is Granted: ~ Waiver is NOT Granted: List Conditions or Reasons for above: ~p~o/w~m& lop ~ Date: ~- 2~-~/_ Re c #: //~t/~?/'~ ~/'~/7/)Am°unt: Name of Reviewer $ //~?6-g) Date Paid: ROBERTC. COWAN, RE. ROBERTA. SHAFER, RE. April 19, 1996 CIVIL ENGINEERS (907) 694-2979 FAX (907) 694-1211 ~LTEST MUNICIPALITY OF ANCHORAGE Department of Health and Human Services P.O. Box 196650 Anchorage, AK. 99519 REFERENCE: Lot 34, Tract B, Eagle Crest S/D Request you issue a permit to upgrade the septic system serving the existing three bedroom house on the referenced property. Also, request you issue a one foot property line waiver due to lack of area. A test hole was excavated and percolation test performed. The approximate location of the test hole is located on the attached site plan. At the time of excavation water no was encountered. The monitoring tube has been checked and found to be dry. Attached is the proposed upgrade design. We do not anticipate any adverse effects on neighboring wells, septic systems or drainage patterns by the installation of the proposed septic system. The proposed 1000 gallon septic tank is to be placed outside the well protective radius. Attached is a site plan which depicts the location of the proposed tank. If you require additional information, please contact us. Robert C. Cowan, P.E. RCC/gk Enclosure 17034 NORTH EAGLE RNER LOOP · SUITE 204 ', EAGLE RIVER, ALASKA 99577 DRAWN J.L.M. iNEW ~000 GAL SEPTIC NEW FAGI F (':RFC:;T ~URRIVIRION R.C.C. DATE4_18_96 ]SET. 2 OF 2 I STRUCTURES, EASEMENTS, OR ENCROACHMENTS SHOWN ON THIS SITE PLAN ARE AS SHOWN ON AN AS-BUILT SURVEY DRAWN BY: DUANE MARK SEWARD IT IS THE RESPONSIBILITY OF THE CONTRACTOR TO VERIFY EASEMENTS, REQUIRED SEPARATION DISTANCES, AND PROPERTY LINES PRIOR TO CONSTRUCTION. 1 O' UTiL. ESMT. CONTRACTOR IS REQUIRED TO OBTAIN UTILITY LOCATES PRIOR TO ANY EXCAVATION WORK. EXISTING CRIB AND SEPTIC TANK DESIGN CRITERIA: $ BDRM = 450 GPD SOILS= 0.8 GPD/SQ.FT.. 450/0.8 SO, FT. REO'D. TRENCH CRITERIA: '7,5' DEEP 4' EFFECTIVE 5' WIDE 60' LONG 2 @ 50' LONG EACH ALL PORTIONS OF SYSTE,M WITH LESS THAN 3.5' OF COVER REQUIRE INSULATION. FIRST STREET CLIENT ME E3C~T DIMENSIONS AND DESIGN pARAMETERS IN THE fl~O, IF NECES~. TO ME~ CONDITIOn. LEGAL LOT 34, TRACT B, DRAWN J.L.M. I CKD. I LOT 28 EAGLE CREST SUBDIVISION R.C.C. iDATE 4-18-96 IS"T. Or 2 STRUCTURES, EASEMENTS, OR ENCROACHMENTS SHOWN ON THIS SITE PLAN ARt' AS SHOWN ON AN AS-BUILT SURVEY DRAWN BY: DUANE MARK SEWARD IT IS THE RESPONSIBILITY OF THE CONTRACTOR TO VERIFY EASEMENTS, REQUIRED SEPARATION DISTANCES, AND PROPERTY LINES PRIOR TO CONSTRUCTION. LOT 27 LOT 26 CONTRACTOR IS REQUIRED TO OBTAIN UTILITY LOCATES PRIOR TO ANY EXCAVATION WORK. N LOT 33 LOT 34 LOT 55 I\ A:..L PORTIONS OF SYSTEM :fITH LESS THAN 3.5' OF C.3VER REQUIRE INSULATION. --- (~ FIRST LOT 40 LOT 39 LOT 38 CLIENT PERFORMED FOR:. Municipality of Anchorage DEPARTMENT OF HEALTH & HUMAN SERVICES 825 'L" Street, Anchorage, Alaska 99502-0650 SOILS LOG ~ PERCOLATION TEST LEGAL 9- 10- 'Township, Range. Section: SLOPE SITE PLAN 13- 14- 15- 16- 17- 18- 19- WAS GROUND WATER ENCOUNTERED? IF YES. AT WHAT DEPTH? ~el~h t~ Waer~r/~,d ' ~1 Itlonitori~g? ~ L"'"~7 Gross Net DePth to Net Reading Date Time Time Weter Drop 20 - PERCOLATION RATE __ Immures/tach) PERC HOLE DIAMETER TEST RUN BETWEEN ~' ' ~"' FTAND '7.a' FT ,_,'/ /_,~ ACCORDANCE WITH ALL STATE AND MUNICIPAL GUIDELINES IN EFFECT ON THIS DATE. 72-008 (Rev. CERTIFY THAT THIS TEST WAS PERFORMED IN ~,~ SOtLS LOG MUNICIPALITY OF ANCHORAGE DEPARTMENT Of' HEALTH AND ENVIRONMENTAL I'ROTECTION SOILS LOG - PERCOLATION TEST r-t Pi eCOLA"hON 1- 3 ~,~¥ 4 S 13- 14- IF YES. AT WHAT DEPTH' · E PERCOL&11ON RAT[. 'TEST RUN GETWE[N ,, FT AND . - IrT · ' ' ' '~"~ ~ "/ '~71 Kr~,v.,/E( ~ I~q~ ~,Il*r ~l~r~J~t- . ,[.,o.,,,o,.~ ,c~,~/_-_,' ,c(.,,,,,o,.:._/.~ ,.A..' 7~,/~ ROBERT C. COWAN, RE. ROBERTA. SHAFER, P.E. ON-SITE WASTEWATER DISPOSAL SYSTEM CONSTRUCTION PRACTICES and MATERIAL SPECIFICATIONS CIVIL ENGINEERS (907) 694-2979 FAX (907) 694-'1211 REFERENCE: Lot 34, Tract B, Eagle Crest S/D April 19, 1996 GENERAL: 1. 0 e e The scope of this project includes the installation of a 1000 gallon septic tank and a five foot wide drainfield to serve the three bedroom residence located on the referenced property. The existing crib and 1000 gal septic tank is to be excavated, pumped, crushed, and removed. Construction shall be in accordance with the approved site plan and design drawings, Municipal permit with any special provisions or conditions, and all applicable State and Municipal Wast.water Disposal Regulations. The contractor shall be responsible for obtaining any necessary underground utility locates. Unless specifically agreed otherwise, the property owner shall be responsible for final grading areas subsequently depressed from soil settling. Contractors installing wast,water disposal systems must be certified by the Municipal Health Department for system installations. Owners installing their own systems must also receive prior approval from the Municipal Health Department. ~EPTIC TANK INST~?.?,RTION= A septic tank is to be constructed by a certified septic tank manufacturer. Construction shall include two 4" cleanouts for pumping access. me The septic tank shall be sufficiently bedded to prevent settling or shifting of the tank. 3. Ail standpipes on the septic tank shall extend a minimum of 12 inches above final grade. 17034 NORTH EAGLE RNER LOOP · SUITE 204 · EAGLE RIVER. ALASKA 99577 Page Two Lot 34, Tract B, Eagle Crest S/D April 19, 1996 e e Septic tanks installed with less than 4 ft. of cover shall be insulated. A foundation clean.ut shall be installed one to four feet from the building foundation. In the line between the tank and the leachfield there shall be two adjacent clean.uts (unless an effluent pumping system exists within the septic tank). These clean.uts shall be located on undisturbed soil not more than 10 ft. from the tank. The first clean.ut, in line, shall be to clean toward the leachfleld. The second clean.ut shall be to clean toward the septic tank. Final grading over the septic tank shall be such that a positive slope exists away from the septic tank. ABSORPTION TRENCH/DRAINFIELD INST~?.~,RTION: Excavate the proposed trench to the dimensions shown on the design. The bottom of the excavation shall be within 2 inches of level. If the sidewalls of the excavation become smeared, they must be raked or scratched (ruffed-up) before gravel (sewer rock) placement. Once the gravel is installed, the distribution pipe is to be installed level with the perforations faced downward. Gravel is then to be placed over the distribution pipe to provide a minimum of 2 inches of cover over the pipe. A silt barrier must be installed between the final gravel layer and the native soil backfill. Ensure the silt barrier covers the entire gravel surface before placing backfill. Monitor tubes shall be of four '(4) inch diameter, installed approximately in the locations shown on the design, and extend a minimum of 12 inches above final grade. The portion of the monitoring tube extending through the gravel shall be perforated from the bottom of the trench to the invert of the distribution pipe. This is equivalent to the effective depth of the gravel as noted on the design. Page Three Lot 34, Tract B, Eagle Crest S/D April 19, 1996 Backfill over the final gravel layer must not be less than twenty-four (24) inches. Insulation must be installed when the backfill depth is less than thirty-six (36) inches. The finish grade over the trench must be mounded to prevent the formation of a depression after settling. MINIMUM MATERIAL SPECIFICATIONS: Any septic tank proposed for installation must be constructed by a Municipally approved septic tank manufacturer. The following pipe materials are approved for use in septic system installations in the Municipality of Anchorage: Type of Pipe Perforated Solid Cast Iron Yes Yes ASTM D3034 (PVC) Yes Yes ASTM F810 (~DPE) Yes No ASTM D2662 (ABS) Yes Yes Use of a type of pipe other than listed above must be approved by the inspecting engineer. Insulation shall be at least 2" thick extruded direct burial polystyrene (Dow Chemical Company Styrofoam HI or equal). Septic tank inlets and outlets shall be fitted with watertight couplings (Caulder, Fernco, or equal). A permeable nontoxic silt barrier (Typar 3401, Mirafi 140N, or equal) must be install6d between the final leachfield gravel layer and the native soil backfill. All leachfield gravel-(sewer rock) shall be 0.5"-2.5" screened gravel with less than 3% passing the #200 sieve. When sand is being used as a filter material, its gradation specifications must conform to current M.O.A. or D.E.C. requirements. Page Four Lot 34, Tract B, Eagle Crest S/D April 19, 1996 XNSPECTIONS= Typically there will be a minimum of three (3) inspections required during the installation of the wastewater disposal system. These inspections will occur as follows: The first inspection must be conducted after the excavation of ditches, pits, trenches, or beds and before the installation of any gravel. A septic tank may be set in place, but may not be backfilled before this inspection. me The second inspection must be conducted after the placement of the silt barrier, gravel, distribution lines, standpipes, cleanouts, and insulation, but before the placement of any other backfill. The final inspection is to occur upon final grading of the property. Often there will be more than these 3 inspections required. Especially with the installation of multiple trenches, sand filters, pressurized distribution systems, etc. Thus, the inspecting engineer is to be contacted at least 24 hours prior to the start of construction. If necessary, a pre-construction meeting will take place on-site. The inspecting engineer will not coordinate, direct or control in any way the contractors activities. The owner shall contract with the contractor to perform the work outlined in these specifications and plans and in accordance with the attached M.O.A. permit. There will be no contractual arrangement existing between the contractor and S & S Engineering. S & S Engineering shall be the owner's representative and will inspect the work as stated above to document the contractors activities. Final acceptance of the contractors work rests with the owner and the M.O.A. Page Five Lot 34, Tract B, Eagle Crest S/D April 19 1996 S & S Engineering shall have no liability to the owner or to others for acts or omissions of the contractor or any other persons performing work on this project or the failure of the contractor to carry out the work in accordance with these construction documents. S & S Engineering's inspecting engineer will not be responsible for the construction means, methods, techniques, sequence, procedures or the safety precautions incident to this project. CONTRACTOR/INSTA?,LER MUNICIPALITY OF ANCHORAGE .. DEPARTMENT OF HEALTH AND ENVIRONMENTAL PROTECTION 82S L. $,eet. Anchm'~. Ala~.ke B9501 264-4720 SOILS LOG - PERCOLATION TEST /~ SOILS LOG J'-I PE RCOLATIDN PERFORMED FOR: LEGAL DESCRIPTION: 8 9 5~'~-.- '~- ~' DATE PERFO.MEO: ?/~'/'~'~ 10- 11 12 13- 14- 15- 16- 17' 18- SLOPE SITE PLAN WAS GROUND WATER ENCOUNTERED? IF YES. AT WHAT DEPTH? Reading Dale Time T,me Water Df OD pr-RCOLATION RATE · TEST RUN BETWEEN . FT AND , FT SE?-20-B4 TUE 10:35 S, O, R, DIV, OF I,I~TER FRX NO. ~075§~1384 P. 07 USGS · ~','ATER t~ELL DRILLERS LOG co. Loc~tion (address of: To',~ship.~.......r, Range,. ~ Section (If kno~); dlstence ~om ro~d: -_ . .,, idle of Casing~ Depth of Hole et, Cased to~ ' , feet, ' ' Static water level~feet (above) (bel~.) land s~iace. Finish of well (check one) Of:ch end ( ~: Screen ( ): Perforated ( ), Describe screen or p~rf~ions: _ lle!l pulp!nE ~}t at~allons per (hr) (m~n) tot ., h~urs with ~' ~eet of dra~vdoivn from ststtc level. R~s~arks ..... ._~ept~. in !ac': from Gi~ye letails cf :ormzti~ns penetrated, siz~]o/ ~,ate:lal. tO tO ~0 · ~ MUNICIPALiTY'0F ANCHORAGE DEPARTMENT OF HEALTH & HUMAN SERVICES Division of Environmental Services On-Site Services Section P.O, Box 196650 Anchorage, Alaska 99519-6650 343-4744 CERTIFICATE OF HEALTH AUTHORITY APPROVAL FOR A SINGLE FAMILY DWELLING ParcelI.D. tt ~5"'O ~// /&, HAA# ~/~cl(-C':~.~,~'' 1. GENERAL INFORMATION Complete legal description Eot 34: Tract "B" Eac~le Crest Subdivision Location (site address or directions) Property owner Mai!lng address Lending agency Mailing address 19057 First Street Eaqle River, AK 99577 PHH/Hcmequity (Wynn) Day phone c/o Jack [%~ite Co. 11823 Old Glenn H~y. Eaqle River, AK 99577 Day phone Agent Barbara Crittenden/ Jack White Co. Address Day phone 694-5500 e Unless otherwise requested, HAA will be held for pickup. NUMBER OF BEDROOMS: .~ '~ TYPE OF WATER SUPPLY: Individual well Xxx Community well Public water RECEIVED NOTE: If community well system, provide written confirmation from State ADEC attest- ing to the legality and status of system. 4. TYPE OF WASTEWATER DISPOSAL: Individual on-site Holding tank Community on-site Public sewer NOTE: If community wastewater system, provide written confirmation from State ADEC attesting to the legality and status of system. 5. STATEMENT OF INSPECTION BY ENGINEER As certified by my seal affixed hereto and as of the validation date shown below, I verify that my investigation of this Health Authority Approval application shows that the on-site water supply and/or wastewater disposal system is safe, functional and adequate for the number of bedrooms and type of structure indicated herein. I fuhher verify that based on the information obtained from the Municipality of Anchorage files and from my investigation and inspection, the on-site water supply and/or wastewater disposal system is in compliance with all Municipal and State codes, ordinances, and regulations in effect on the date of this inspection. Phone $ & S ENGINEERING Name of Firm ~7~4 ~-~:,. ....... ,- ............ Eagle River, Alaska ~9577 Engineer's signature Date DHHS SIGNATURE ~ Approved for -~ Disapproved. Conditional approval for bedrooms. bedrooms, 'with the following stipulations: Additional Comments Date The Mu~cil~lity of A~bhorage Department of Health and Human Services (DHHS) issues Health Authority Approval Ce~ificates based only upon the representations given in paragraph 5 above by an independent professional engineer registered in the State of Alaska. The DHHS does this as a courtesy to purchasers of homes and their lending institutions in order to satisfy certain federal and state requirements. Employees of DHHS do not conduct inspections or analyze data before a certificate is issued. The Municipality of Anchorage is not responsible for errors or omissions in the professional engineer's work. Municipality of Anchorage DEPARTMENT OF HEALTH & HUMAN SERVICES Environmental Services Division 825"L" Street, Room 502 · Anchorage, Alaska 99501· (907) 343-4744 Health Authority Approval Checklist Legal Description: ~o~''St~ '"~'ff.-.~e.~'~' ~,~..~ ~t-~m:elLD.: A. WELL DATA Wellt.~pe ~¢t-'~t~e.rL- lfA. B. orC. attach.~DECletter. ADECwatersystemmtmber Log present ~) q Date completed "/.- Z~ -- '7'7..- To~ depth 24-~( Ca,~d to z47 ' FROM WELL LOG Date of le~l '7 Static water level Well production WATER SAMPLE RESULTS: Casing height (above ground) proper .ly protected t~N) ~ Wires ~.., AT INSPECTION '~ ~,o '~ _ Coliform 0 SEPTIC/HOLDING TANK DATA Nitrate /. $ S- Other bacteria Collected by: s & s ~NGll~ntNO 17034 Eagle River Loop Roicl NO. 2G4 Eagle River, Alaska 99.~77 AI~ORFFION l,-[~ct.l~ DATA ~ ~0 ' Wi~ ~ ~ G~I ~ ~low pi~ ~ t To~ ~ ~, ~ Eff~ve ~Uon ~ ~ ~ ~ang TU~ p~ ~ ~ion ~r field (V~ ~ D~ of ~ I~ J/~ ~ ~ (~) For ~ Fluid depth in absorption field before tesl (in.); Fluid d~th. '""'--- .(ins.) Minute~ later: -' Peroxide tte~tmem (past 12 months) (Y,~ lrttmedia!ei.x' a~r"-"'--gaJ, water ~dd~ (in.): Absorption rate = g.p.d. If yes. give dote D. LIFF STATION Date it~alled Siz~ in gallons Manhole/Access (Y/N) "Pump on" level al* High water alarm level al* ~ *Datum E. SEPARATION DISTANCES SEPARATION DISTANCES FROM WELL ON LOT TO: Septic/holding tank on Iol Absorption field on lot Public ses~r main Sewer/septic service line : On adjacem lots : On adjacent lots Public sewer manhole/cleanoul tion SEPARATION DISTANCES FROM SEPTIC/HOLDING TANK ON LOT TO: Building foundation Water muin/se~ice line Properly. line /O t Absorption field Surface water/drninnse ~ Wells on adjacent lots SEPARATION DISTANCE FROM ABSORPTION FIELD ON LOT TO: Building foundation "~ ~ ' Water main/service line Surface water ~'~ g:~ ~ ¥ Driveway, parking/vehicle s~orage area Curtain drain ~'~J~ Wells on a~jacent lois I~-~t'~ Property. line F. ENGINEER'S CERTIFICATION I certeS, that I ha~t d*t*rrnmed thru field inspections and re~e~ ofMuniC~l~l r*cordx "-. Date HAA Fee $ .~OZ9,0 o Date of Payment f-/b~ ~, Rev. 8/95 O$S: haa.wkdoc Waiver Fee $ Date of Payment Receipt Number 0~/10x96 11H~9 CT&E ESI AN(~AGE ~ 9~76941211 N0.9~9 ~ CT&E Environmental Services Inc. Laboratory Division ~ Laboratory Analysis Report CT&£ Eer.# 961202.9517 Client Sample [D L34 TRACT I~ £AG CREST[ 120~-Ot Matrix Ddnklng Water Collected Date 04104196 TechniCal Directo~ Sample Kema~k$: Nitrete-N 1.~,~ -- 0.100 mg/L EPA ~,~3.Z 0~/O9/9~ 0~.109/96 eau 200 W. Po~ter Drive, Anchorage. AK 99518.1606 -- Tel: (907) 562.2343 Fax: (907) $61-5301 3180 Peger Road. Fairbanks, AK 99709-5471 -- Tel: (907) 4?4-8656 Fax; (907) 474-9695 ENVIRONMENTAL FACILITIES IN ALASKA. CALIFORNIA, FLORIDA. ILLINOIS. MARYLAND. MICHIGAN, MISSOURI. NEW JERSEY. OHIO. WEST VIRGINIA Parcel I.D. # , (~ MUNICIPALITY 0F ANCHORAGE . DEPARTMENT OF HEALTH & HUMAN SERVICES. "- ~' Division of Environmental Services . . : -.~ ,* '. · * . .:.On-Site Serv ces Section P.O. Box 196650. Anchorage.'Alaska 99519-6650 CERTIFICATE OF HEALTH AUTHORITY APPROVAL FOR A SINGLE FAMILY DWELLING 05'0 '~1 I ~,, HAA# J-lA GENERAL INFORMA ....... ' ' ' TION -, Complete legal description Lo:~ $4; T~z~ Location (site address or directions) ' !9057 F~t~:~ Property owner .7o/~ Fu~0~ Day phone Mail[r~g address ~ ~057 F~t~:t $:t~[~ E~ ~ Lending agency _ -- Mailing address Agent Address ~ :'- Unless otherwise requested, HAA will be held for pickup. NUMBER OF BEDROOMS: ~ .... 3. TYPE OF WATER SUPPL~: ' Day phone_ Day phone Individual YJ(X ..... NOTE: If co~lm~-nl~/'~v~l/'~s~em,~p~vide written confirmation from State ADEC__attest* '"{ lng to the legality and status of system. 4. ~ 'TYPE OF WASTEWATER DISPOSAL: Individual on-site XYJ( oldlng tank ;;;; ~.'-' ,'::. ':*...- ' · :;: ,.' · Community'~n;site'.,' ,.'- ' ". ' - ;' - · '"' '" ' .* -~* '.'.:. ' ,' ..... ,..~ .... L-.~-..2. ~. . '' '"' ,:,:~:i.~:.'-' ;"; *. '' . =. . ~ ' ., *~., ~,/ ..... ;,.~;_.,~_! ...~,,~ .... ,. '~ ...... ..~. . ~.!,_ ~'~,.~ ...~'.' .... . NOTE. If communi~ wastewater system, provide walden confi~ation from ~ta~; ~EC ~.'%'; ..:,.... ' a~ting to the legal~ a~sta{us of s~tem.~ ....... : . .,..... ?. ,:, .- -; -. - .,;;- ' .,,. ' .., ~./~.~,?~c~.., .... · -. . . . STATEMENT OF INSPECTION BY ENGINEER As certified by mY seai affixed hereto and as of the validation date shown below, I verify that my investigation of this Health Authority Approval application shows that the on-site water supply and/or wastewater disposal system Is safe, functional and adequate for the number of bedrooms and type of structure Indicated herein. I further vedfy that based on the information obtained from the Municipality of Anchorage files and from my investigation and inspection, the on-site water supply and/or wastewater disposal system Is in compliance .with all Municipal and State codes, ordinances, and .regulations in effect on the date of this inspection. Name of Firm s & S ENGINEERING Phone 7034 Ea~le River Loop Road Address ~ Date ~ Engineer's signature I~rooms, with the following stipulations: ~ ::~: "Additional comments' The MUnicipality of Anbho'rage Department of Health and Human Services' (DHHS) Issues Health Authority .. Approval .Certificates based only upon the mpre~entations given in pa.r:agral~h 5 above by an Independent professi~na~eng~neerregistered~ntheState~fA~aska~TheDHHsd~esthIsasac~udes~/t~purchaears~fh~mes.. __ __ · '; andth~r~.ndina~nstit~t~ns~n~rdert~atisfv~ertainfedera~andstatem~u~rements-Em~vess~fDHHSd~n~t - .- · . ' ~3~d~Jct'ln~oections or. analyze data before a c~rtificate is Issued. ~rhe Municl .l~.)lty of Anchorage is not . ~, ". ' . resp~nsi~ef~rerr~rs~-~mIss~ns~ntheprofessi~a~eng~neer~s~rk::;-:i:~;~``i~i~:~::~;~. : ':.. ': ' ": '"~i. Municipality of Anchorage Department of Health and Human Services HEALTH AUTHORITY APPROVAL CHECKLIST Legal Description: ~ Z~ -.~ {~ ~,,~. Parcel I.D. O 5'"0 ~- 9 ! A. Wall Data Well type '~-~I~ If A, B, or C, attach ADEC letter. ADEC water system number ~-I1~ FROM WELL LOG /5" 7-,~-77-- Driller ~-~.c.~ Z~,~-,-.J'~. 2.17 ' Casing height Wires properly protected {~)N) Log present(~N) Total depth Sanitary seal Date of test Static water level Well flow Pump level1 SEPARATION DISTANCES FROM WELL TO: Seplic/holding tank on lot Absorption field on lot Public sewer main Sewer service line Date completed Cased to .g.p.m. WATER SAMPLE RESULTS: Coliform ~:) Nitrate Date of sample: ~-.'~ / '=/- 13 1.13 Collected by: Other bacteda ~) B. SEPTIC/HOLDING TANK DATA Date installed ~"/'?.~- Cleanouts ~,1) High water alarm Date of pumping Tank size '~. ~ ~ Compartments Foundation cleanout ~N) ~" Depression (Y/~) ,J Alarm tested (Y/N) ," SEPARATION DISTANCES FROM SEPTIC/HOLDING TANK TO: Well(s) on lot \o<> t~ To property line ~. ~, Surface water/drainage On adjacent lots ~ c, ~ Foundation Absorption field ~-- J '~' .Water main/service line Io0 ~2-02~ (3,~)' Ffo.t CONTINUED ON BACK PAGE C. UFT STATION Date installed Manufacturer Size in gallons Manhole/Access (Y/N) ' ~ 'Pump on" level at _ 'Pu~j33poff"'L~elat~ Vent High water alarm level ,,.C/c~s tested . . . Meets MOA electrical codes (Y/N) ~ ~ . SEP~ATION TO: We-l~on lot On adjacent lots .Surface w~ter. D. ABSORPTION FIELD DATA Date installed I ~ .. Length. ' UI/ W'dh · :. Total ~rpt~n area "Date of adequacy test Water'level Ih absorplion field before lest · Peroxide treatment (past 12 months) (Y~ Soil rating (GPD/FF) -~ ·~ o '~//~'~-System type /~ -r- ~j/Z_. Gravel thickness {J~- Total depth N ~, 5' Cleanout present (~'N) ~' Depression over field (Y~) ~/' Results~il) ~ /',,,~ for /~ ~ Bedrooms D '~ Nter~est 2-~. ' /Jo,~/~-/~-,J~ ~J ,~' ff yes, give date /'~/~ SEPARATION DISTANCE FROM ABSO.RPTION FIELDTO: ~" ~,J~-y ~-~-~,'~-~'~ ,~ Well on lot /oo To building foundation On adjacent lots ' ,,~c, Suflace water / o o Curtain drain r ~ F-- ENGINEER'S CERTIFICATION On adjacent lots /~>o /''' Property line ~ 5- ~ '/'' To existing or abandoned system on lot "- Cu~ank 'J//,~ Water main/service line Driveway, parking/vehicle storage area I cerb'fy that I have checked, vedfled, or conformed to all MOA and HAA Date '0 / HAA Fee $ ~) Date of Payment Waiver Fee $ Date of Payment Receip{ Number. CT&E Ref.# Client Sample ID l~latrix Commercial Testing & Engineering Co. Environmental Laboratory Services LABORATORY ANALYSIS REPORT 94.4~3-3 LOT 34 ~ 'B" ~GLE C~ST S~ WAlK ClientName S & S ENGINEERING WORK Order 82232 Ordered By PJS Printed Date 09.r20/94 ~ 09:41 hrs. Project Name Collected Date 09/13/94 ~11:15 hrs. Project# Received Date 09114/94 ~16:55 tu'~. PWSID UA Technical Director STEPtlEN C. EDE Sample Remarks: ROUTINE SAMPLE COLLECTED BY: RAY. QC Allowable Ext. Anal Parameter Results Qual Units Method Limits Date Date Init Nitrate-N 1.13 mg/L EPA 353.2/300.0 10 09/16/94 CMR * See Special Instructions Above UA=Unavailable ** See Sample Remarks Above NA = Not Analyzed U = Undetected, RepoSed value is the practical quantification limit. LT= L~ss 'lhnn ~ D = Secondary dilution. GT= Cseater Than 7. ,' 5633 B Street, Anchorage, AK 99518-1600 -- Tel: {907) 562-2343 Fax: (907) 561-5301 ENVIRONMENTAL FACILITIES IN ALASKA. COLORADO, FLORIDA, ILLINOIS, MARYLAND. NEW JERSEY, OHIO. UTAH, WEST VIRGINIA MUNICIPALITY OF A~CRORA~E DIVISION OF ENVIRO~MZNTAL HEALTH DEPARTMEN~f OF HEALTR AND ENVIROnMeNTAL PROTECTION APPLICATION F0K HEALTH AUTHORITY APPROVAL CERTIFICATE 1. General Information Application Date (a) Legal Description (include lot, block, subdivision, section, township, range) Location (address or direc~io~) (c) Applicant is (check one) LeMi~ Institution ~; ~er/b~lder ~ ; Buyer ~ ; Other [ [ (explain); (d) LendlnE Institution .... /. tt /~ {?/ (e) Real EsEa~e Co, & Aien: ~/~ Telephone /~,ff-f ~2_~! Address (f) Telephone Hail the HAA to the following address: ?/v Type of Residence Single-Family~ Number of Bedrooms Hulti-FamtlyF--~ Other (describe) 3. Water Supply' Individual Well~-~ Comauni~y~---~ Public~-~ Note: If community well system, must have written confirmation from the State Department of Environmental Conservation attesting to the legality and status. de Sewage Disposal .' '" ..,. · :j.,? · . Onsit, ~--~ Public ~ Comdu.n. ity ~-l.:' :: ~olding Tank ~ No~e: If community ~ll system,' must .have.~l~te~.co~i~a~ion from the S~ace Department of Enviro~en~al Con~e~ation'at~dsting to the legality aM s:atus. [Page 1 of 2] 5. En~ineerin~ Firm Providin~ lnspectio~s~ Testa~ File Search~ Data and Information As certified by my seal affixed hereto and as of the validation date sho~n below, I verify that my investigation of this Health Authority Approval shows that the on-site water supply and/or ~rastewater disposal system is safe, functional and adequate for the number of bedrooms and type of structure indicated herein. I further verify that, based on the information obtained from the I~uni¢ipality of Anchorage files 'and from my investigation and inspection, the on-site water supply and/or wastewater disposal system is in compliance with all Municipal and State codes, ordinances, and regula- tions in effect on the date of this inspection. Date 9' ~ 0~ :-.~. ~ .,,; ..,. , DHEP Approval Approved for_~__ Approved ~, bedrooms Disapproved Conditional Terms of Conditional Approval CAUTION THE HL~ICIPALITY OF ~NCHORAGE DEPARTMENT OF f~.,~LTH AND Eh~IROh%~}~AL PROTECTION (DHEP) ISSUES HEALTH AUTHORITY APPROVAL CERTIFICATES BASED SOLELY UPON TRE REPRESE,N~- ATIONS GIVEN IN PARAG~H 5 ABOVE BY ~N INDEPENDENT PROFESSIONAL ENGIh~ER REGISTERED IN THE STATE OF ALASKA. TH~ DflEP DOES THIS AS A COURTESY TO PURCHASERS OF HOMES ~ND THEIR LENDING INSTITUTIONS IN ORDER TO SATISFY CERTAIN FEDERAL AND STATE REQUIRE- HENTS. ~tPLOYEES OF L~/EP DO NOT CONDUCT INSPECTIONS OR ~NALYZE DATA BEFORE A CERTIFICATE IS ISSUED. THE HUNIOIPALITY OF ANCHORAGE IS NOT RESPONSIBLE FOR EPHORS OR OMISSIONS I~ THE PROFESSIONAL ENGINEER'S ~ORK. P,.Ri/el/Di8 [Page 2 of 2] (DIIEP SEAL) 7-19-84 A. ~ELL ~TA MUNICIPALITY O~ ~NCHOR~GE (MOA) HEALTH AUTHORITY APPROVAL (HAA) CMEC~IST- FEBI~ARY 1984 Legal Description: Static ~4ater Casing Hsight Above Ground /.~- Electrical Wiring in Conduit .(Y/N) Separation Dista~s f~cm Wsll: To Septic/Holding Tank. To Nea~st Edge of ;~tion Field To Nearest public Ss~= Line ; ~n Adjoining Lots /~ ' ~ ; On Adjoining Lots ./~/'~ ~-/~' To Nsa~est Publi. c_~Sew~r' Cleanout/Manhole .~'~3~'~ .~N_q~ To N~a=est Sews~ Se~vi~e Lihs on LOt c-~- ' ~- Wa~ S~ ~st ~sul~ B. S, EPTIC/I'iOLDING TANK [1%TA D~ts Installed I~7~ Size ~. CQ.~ NO. of C~a~tmsnts 1 S~i~s (Y~) ~F3 Ai~ti~t ~ (Y~)~ F~n~ti~ C~a~t (Y~) ~e~i~ ~r Ta~ (Y~)~ ~ ~a~t ~d ~i~in~ ~a~ ~ Fi~ (Y~)/]~ ; f~ ~ati~ Dist~s ~ ~pttc~di~ Ta~: To ~~ly ~11 /~ / ~ To ~.ildi~ F~n~ti~ /~ ' ~ TO ~rty ~ /~' ~ TO ~al Field ~--~ ~ To ~ter ~i~i~ Li~ lb-' ~ ~'S~m, ~, ~, ~ ~j~ ~ai~ C~ Ce ABSORP~ON F~ELD I~A Date Installed /~?~- Length of Field Width of Field /////f)/,~?)/3 ~p~ of Fi. Id Gra%~l Bed Thickness ///~//r'/V.~ Id/r) Square Feet of Abso~tion A=ea [)N~/Vdu3~/ StanclpiL~es P=esent (Y/N) ~/~__~ Delm, ession ove~ Field (Y/N) ~/~ Date Of last ~squao/ ~est Rasults Of r*~t ~cy ~st ~Da~ation Dism f]rm At~<~tim Field: Zo Wate~l~ply all .<S~ ~ l~<~rty Line /S-~ · o ~iidir~ Foundatio~ ~.,f ~ ~ To L~istir~ c~ ~ar~cned System cn Lot /,/,~'/C ~'/C,9 ; On Adjoining Lots ~O ' ~- To ~ate~ Main/Service Line ~,~/~/ ~ To Cutbank(if ~-esent) 7o s~/~/~/~ ~ ~.ins~ e=~ ?/.//7~ TO D=iveway, Pa~king A~ea, (x Vehicle Stc=ags A~a ~--/ De LIF~ STATION Date Installed Size in Gallons "Pump On' Leal at High Water Alarm Leal at Tested fo= Elect=ical Cocbs (Y/N) Cements Dimensions Manhole/a~ess (Y/N) "Pump Off" Level at Vent (Y/N) Pumping Cycles du=ing Adsqua~Z ~st. ** C~eck Permitted Bed~oc~ Rating Against HAA Bequest on t...~i. ~V~~ KB1/dS/s [Page 2 of 2] BAA Guidelines in effect 4,?~ OF. AC~ I · e~'.... .... ~e; ~ 2-15-84 7 8 91 2 3 4 5 6 7 8 9]. 2 3 4 5 6 7 8 91 ............... :..~...~...~:.~x'...~ ..~.c .: . ..:::::~ :::: :::::::::::::::~:: ~:::~ :~::, .:::::':::: :::: :::~ :: , .... ~'- ..................... ~ ..... / .......................................... ~ .............................. ~.~., ~...,,,/~ ...l ~¢ ........ .......... .,~. .... ...... .... .......... .............. .... , ......... ; ...... ..... .!~¢, .... ............. ' X .... .... ' .... ' ' ~ ~ -i · ~ t~ ~"7,7¢Z ~ ~ DIRECTIONS: Complet~ =il ~,rts on ~ 1. I.~.l;Im r~lu.l~ wiU r~t b~ pr;i~il(~W~~l~) PROPERTY OWNER 4Al LING ADDRE~ BUYER LAI LING ~,~RF.~ PHONE PHONE PHONE I ~rREET L~CATION * TYPE OF RESIDENCE NUMBER OF BEDROOMS [~ SINGLE FAMILY · [] MULTIPLE FAMILY 7. WATER EUI~'LY INDIVIDUAL* [] COMMUNITY [] PUBLIC UTILITY 8. EEWAGE DIS _PO~_~L BYSTEM [~ INDIVIDUAL/ON*SITE** I-1 PUBLIC UTI LITY [] One [] Four ~ Two [] Five [] Three [] Six [] Other * ATTACH WE LL LOG. A w~ll log is requireS for all walls drilleS ~ since June 1975. For walls drilled prior to that date, give wall depth (attach log if available.) I I 'J I f//!/~. **If individual/on-site, give installation data /C~ -7.0, . bylf systemthis Department.is over two (2) years old an adequacy t~st is required/ NOTE: THE INSPECTION FEE MUST ACCOMPANY EAcH REQUEST BEFORE PROCESSING CAN BE INITIATED. 72..010(3178) · ~' ~ ~' THIS SIDE FOR OFFICIAL USE ONLY ~ DATE RECEIVEO , INSPECTION APPOINTMENTS TIME TIME TIME DATE DATE DATE INSPECTOR INSPECTOR INSPECTOR DIRECTIONS: 'L TYPE OF RESIDENCE NUMBER OF BEDROOMS I'-1 SINGLE FAMILY [] ONE [] THREE i-'l FiVE I-'1 OTHER [] MULTIPLE FAMILY [] TWO [] FOUR [] SIX PERMIT NUMBER 2. WATER SUPPLY [] INDIVIDUAL DEPTH OF WELL [-'] COMMUNITY DATE DRILLED [] PUBLIC UTILITY Connection Verified LOG RECEIVED 3, SEWAGE DISPOSAL SYSTEM PERMIT NUMBER [] INDIVIDUAL/ON -SITE DATE INSTALLED []PUBLIC UTILITY Connection Verified INSTALLER [] Septic Tank or [] Holding Tank Size: If Tank is homemade SOILS RATING give dimamions: TYPE OF TANK MANUFACTURER TOTAL ABSORPTION AREA MATERIAL 8. COMMENTS [] CONDITIONAL APPROVAL (letter must accompany certificate) [] DISAPPROVED 72~)10 (Rev. 3/78) October 24, 1970 Carolyn ~chr. u~rlo Anchorage, Alask~ 9950) ~ubJect~ Tract ~ Lot 34 =agl~ Crest Subdivision Approval for your ln~lvidual sawer and water facilities will not bo gran~e~ () () Aw ell log is submittua to ~hia d~partm~n~. Th~ top of ~hQ w~ll ca,lng is sealed with a ~anitary seal so that () T~o deprcssion or pit around ~hu w~ll casing should be filled ~lth i~nervloue t}~ soil so t~h it slopes a~ay £rom tho () %,, (x) Th~ well camin~ i-- er. tended twelve(12) inches above ground level. ~partm~nt. A four(~) inch oa=t iron cleanout he inBtalled to the septic tan); or leachin~ area. A ~rcolation test bo pcr£orm, ed on th~ existin? leaching area. ~.,xis will determine if the system ia adequate accor~in~ to ]~ational ~andards. A list of ~rlvats fir~s w~ ~erfozmthe test la avail- able at ~his office. () th~ sewer system ~as orginally approved for. Thmrefor~ an u~rade will be required. 2;otify ~is departm~nt for a re-inspection when ~e~repancies have been office at 264-4720. Sincerely, r4~rt c. ~rattl R.~. Associate Specialist MECHAH I CAL ENGINEER DAVID SLE~IP 694-9055 S&S ENGIIIEERIIIG 'SRB 196X EAGLE RIVER, ALASKA 99577 7 November 1978 CIVIL ENGINEER ROBERT A. SIIAFER 694-2979 Star Realty ATTN: Mr. ~ax Bevins 640 West 36th Street Anchorage, AK 99503 Property located on Tract B, Lot 3~, Eagle Crest Subdivision Dear Hr. Bevins: A sewer system adequacy test was conducted per your request on 4 and 5 November 1978. The septic tank was pumped and.1500 gallons were removed. This did not completely empty the tank and though the tank is verified to have a capacity in excess of 1500 gallons, it is estimated the tank has 2,000 gallons. Excavation took place to locate the seepage pit and cleanout. The water level in the seepage pit was recorded and the pit charged with 750 gallons of water. Percolation over a 24 hour period as recorded on $ November 1978, resulted in the removal of 700 gallons or 350 gallons per bedroom. It can be con- cluded that the percolation through this seepage pit is adequate for the two bedroom residence. On the basis of the above survey and test, it ts determined that the system (septic tank and seepage pit) is adequate. 1 Incl CF: Dept of Health and Environmental Protection Ve.ry...r~uly yours,.) , < !