Loading...
HomeMy WebLinkAboutTHE VILLAGES LT 1Th Village Lot ! #020-29! -55 Municipality ofAnchorage Page I of Development Services Department euilding Safely Division On.Site Water and Wastewater Program 4700 South Bragaw Street P.O. Box 196650 Anchorage. AK 99519-6650 www.ci.anchorage.ak.us (907) 343-7904 ON-SITE WASTEWATER DISPOSAL SYSTEM ANO/OR WELL INSPECTION REPORT Permit Number: SW010202 PID Number: 020-291-55 n~,,: Wastewater System: New David M. Tish P.O. Box 1'13261 Anch, AK 995'11 ABSORPTION FIELD w,,~,: m,,~,~ ,~ s~,,,,: Deep Trench 345-5798 Four (4) LEGAL DESCRIPTION .8 ~ 7 '1 The Villages 3 ~. 4 · 5 f,. 80 f~. Well: New 5 r~. Private 267 ~. 3.03. r,. 800 fe ASTM D3034 PVC Alpine Drilling 6/26/01 82 ,,. Denali Sewer & Drain 6/22-25/01 v.: i ~=,.~p s,.: lc.m, ~ ,,~,. c,,o~: TANK 4 c,,u ~. >2 ~ SEPARATION DISTANCES E~ s~c n Holding [3 S,T.E.P. T.~,~To Septic Absorption Oft Holding ~blic/P~vate 'rank Find St,,on Ta,k S~.,,U,, Anchorage Tank -1,250 w., >'100' >'100' N/A N/A >25' Steel Two (2) s~...w.,, >-100' >-100' N/A N/A ~ / LIFT STATION - NONE ON LOT ~ >5' >!0' N/A N/A ~ >5' >-10' N/A N/A '~'~'~" '~"~ ~'"~'~' ' c~,~:.~ I None Noted '~"~'~'*~ e~.,~: BENCH MARK Z" Direct Uury Insulation Over beptic lank and Garage Floor. 100.0 Engineer's ,51a m p Inspections performed by: A. Harala Dates: 1" 6/22/01 Department of Health and Human Services approval Reviewed and approved bY~~ /[~. P~¢~. Date: ~. q_~.~ Municipality of Anchorage DEVELOPMENT SERVICES DEPARTMENT 4700 South Bragaw Street Anchorage, AK 99519-6650 - 343-7904 On-Site Wastewater Disposal System or Well Inspection Report Page 2 of 3 Permit Number $W010202 PID No. 020-291-55 THE S 89'57'; F E 254.65' A B S1 64.6 50.5 S2 74.2 60.4 C4 78.5 78.3 M 1 76.5 76.2 C5 125.2 100.8 M2 124.7 100.4 Porch .isting Ccovel -- Drive \ Lot ~1 \ 1.97 Acres \ N 89'5T01" W 142.22' TRACT 7B-1 PLAN AS-BUILT SCALE 1" = 60' Municipality of Anchorage DEVEOPMENT SERVICES DEPARTMENT 4700 South Bragaw SL~eet Anchorage, AK. 99519-6655 - 343-7904 On-Site Wastewater Disposal System or Well Inspection Report Permit Number. SW010202 Page 3 of PID No. 020-291-55 ~---~~/!~2,5'0~ 97.1 Sep"c~c T 2' In/"0sil.BACKIrILL 94.S /. Geotextite Fob~'ic and 2' Insulation 91.5 / Dr'eintield Rock ,/~78.8 Pipe - PROFILE AS-BUILT Scale: 1= .,, 10' Municipality of Anchorage Department of Health and Human Services 825 'L' Street P.O. Box 196650 Anchorage, Alaska 99519-6650 Rick Mystrom htr p://www.cl.anchora.~e.aK.ua Mayor Permit Number: #SW 010202 Date oflssuc: 6-21-01 Date Star~&l: 6-22-01 Date Completed: 6-26-01 Legal Description: Property Owner Name & Address: Parcel Identification Number:. 020-291-55 Is well located at approved permit location? [] Yes [] No The V#laqes Lot I David Tish PO Box 113261 Anchorage, Ak 99511 Borehole Data: Depth (It) Soil Type, Thickness & Water S~ata From To stick-up 0 2 organic & silt 2 4 gravelly silt 4 21 Silty gravel 21 42 silt 42 93 Bedrock 93 267 H20 250 267 Method of Drilling [] air rotary I"'l cable tool Casing type: steel Wall Thickness: .025 inches Diameter: _~ inches Depth: 101 feet Liner Type: Diameter: __ inches Depth: ~ Casing stlckup above ground: _2 feet feet Static water level (from ground level): 82 feet Pumping Icvel:, 267 feet after ~0 hours pumping ~_ gpm Recovery Rate: _~ gpm Method of Testing: airlift Well Intake Opening Type: [] Open End [] Open Hole [] Screened Slart ~ feet Stopped ~ [] Perforations Start ~ feet Stopped feet Grout Type: Bentonite # 8 Volume: I bg Depth: Start 0 feet Stopped+feet Pump: Intake Depth feet Pump size __ hp Brand Name __ Well Disinfected Upon Completion? [] Yes [] No Method ofDislnfection: .OIodne Tablets Comments: Well Driller: Alpine Ddlling & Enterprises P 0 Box 110496 Anchorage AK 99511 Attention: Thc well driller shall provide a well log to the property'owner within 30 days of completion and the property Municipality of Anchorage :? George 15 Wuerch, Mayor ~. Building $~ffciy Division ~ I'.(). Ikm 196tkqo · 47(~) s. Bragaw Street Anchorage, Alas~ ~)519-(~) * (~)7) 3~3-~01 ]ltlp://x~x~v.ci.anchoragc.ak.us May 21, 2002 David M. Tish PO Box 113261 Anchorage AK 99511-3261 Subject: On-Site Water and/or Wastewater Permit. Permit Number: SW010202 ~Legal Description: The Villages Lot I ' ) Dear David M. Tish: An On-Site Water/Wastewater Permit, number SW010202, issued by this office for a single-family system, will expire on June 21, 2002. This permit was valid for 365 calendar days. If this was a well permit and the well has been drilled, a well log must be sent to this office for documentation of the installation and to close the permit. If this permit was for a wastewater disposal system, an original as-built inspection report must be sent to this office for review, approval and documentation. This as-built inspection report must be signed by the licensed Professional Engineer who inspected the installation of the system. As-built inspection reports are required to be submitted within 30 days ofthe completion ofthe system. If no system was installed under this permit, and you are still planning to install a well or wastewater disposal system, a new permit must be obtained from this office. A new permit for a second year may be issued for a fee of $100.00 if the renewal application is received on or before the expiration date of the original permit. When applying for a new permit, the fees are: $400.00 for a wastewater permit and $150.00 for a well permit. If you have any questions, please call this office at 343-7904. Sincerely, Dan Roth, Civil Engineer II Acting Manager On-Site Water and Wastewater Program Enc: Copy of permit MUNICIPALITY OF ANCHORAGE Development Services Department On-Site Water & Wastewater Program 4700 South Bragaw Street P.O. Box 196650, Anchorage, AK 99519-6650 (907) 343-7904 ON-SITE WASTEWATER DISPOSAL SYSTEM I WATER SUPPLY PERMIT Initial Date Issued: Jun 21, 2001 Expiration Date: Jun 21, 2002 Permit Number: SW010202 Legal Description: The Villages Lot 1 Design Engineer: 0014 Anderson Engineering Owner Name: David M. Tish Owner Address: PO Box 113261 Anchorage, AK 99511-3261 Parcel ID: 020-291-55 Site Address: NHN Villages Scenic Pkwy Lot Size: 85918 SQ. FT. Total Bedrooms: 4 Permit Bedrooms: 4 This permit is for the construction of: i'~ Disposal Field [] SepticTank [] Holding Tank [] Privy [] Private Well [] Water Storage All construction must be in accordance with: 1. The attached approved design. 2. Ail requirements specified in Anchorage Municipal Code Chapters 15.55 and 15.65 and the State of Alaska Wastewater Disposal Regulations ( 18AAC72 ) and Drinking Water Regulations ( 18AAC80 ). 3. The engineer must notify DSD at least 2 hours prior to each inspection. Provide notification by calling (907) 343-7904 ( 24 hours ). ( Not required for a Water Supply Permit only ). 4. From October 15 to April 15, a subsurface soil absorption system under construction during freezing weather must be either: A. Open and closed on the same day. B. Covered, sealed, and heated to prevent freezing. Received By: *'7~-,~-~ ~ ~ Date: MUnicipality of Anchorage Development Services Department Building Safety Division On-Site Water and Wastewater Program 4700 South Bragaw St. P.O. Box 196650 Anchorage, AK 99519-6650 www.ci.anchorage.ak.us (907) 343-7904 ON-SITE SEWER/VVELL PERMIT APPLICATION FOR A SINGLE FAMILY DWELLING Parcel I.D. 020-291-55 Permit Number SWO ] O ~. 0 ~. Property owner(s) David M. Tish Mailing address (1) P.O. Box 113261 Anchora.qe, AK 99511-3261 Me~,~j address (2) b/I.{-fq ~;ll~tz,~-_~,~_.'-'~,Z.~.o~j.t Legal description (Lot, Block & Sub'd.) Lot 1t The Villa.qes Subdivision Legal description (Section, Township & Range) Lot Size ~ I ~' Acres/~ Day phone 345-5798 Zip Code Number of Bedrooms Four (4) THIS APPLICATION IS FOR: Sewer Only Sewer and Well Sewer Upgrade THIS PROPERTY CONTAINS: Hot Tub Swimming Pool Therapy Pool [] Well Only [] [] Water Storage [] Jacuzzi [~ Water Softening Unit I cedify that the above information is correct. I further certify that this application is being made for a Single Family Dwelling and is in accordance with applicable Municipal Codes. (Signature of property owner or authorized agent) Permit Fees: Date of Payment: Receipt Number: (Rev. 12JO0) ~t~/o ~ ~ - ~7o! Waiver Fees: Date of Payment: Receipt Number: ANDERSON ENGINEERING - - .1~;0: Box' 240773 - ANCHORAGE, AK 99524 522-7773 522-6779 (FAX} June 12,2001 Municipality of Anchorage Development Services Department On-Site Water and Wastewater Program 4700 South Bragaw Street Anchorage, AK 99519-6650 Subject: Lot 1, The Villages Subdivision Septic System Design and Permit Application Impacts to Adjacent Properties Dear Onsite Services Engineer: The owner of Lot 1, The Villages Subdivision intends to construct a three-bedroom home on the lot with a detached garage. The garage will also have one bedroom and a bathroom which will tie into the septic tank. We are therefore applying for a permit to construct a new septic system on the lot to serve the new home. The attached Site Plan and backup documentation identify the location and configuration of the new septic system and the parameters used in the design. Also identified on the plans are th~loca~ion of the existing well along with the test hole and the existing absorption site. Existing drainage patterns are shown and will not be altered by the development of the lot, We have surveyed the area and the new system will not conflict with other wells or septic systems in the area. Three test holes were recently p!aced on the lot to dete?ne subsu.ff, ace conditions. Soils were found to be gravel with varying amounts of silt. Percolation tests in the matedal indicated rates approximating 9 to 10 minutes per inch with one test over 40 minutes per Inch. No groundwater was found dudng the excavation and none was found dudng the monitoring pedod. We are therefore proposing to place an absorption trench 75' long by 5' wide with a 4' effective depth to treat the septic effluent. The distribution pipe will be placed at 2' below the surface for a total depth of 6'. The trench will be placed as shallowly as possible to take advantage of the looser material. The ground surface on the lot slopes as shown on the attached Site Plan with grades from east to west that flatten in the area of the proposed absorption trench. The new absorption trench will be constructed parallel to the contours of the surface as much as possible in conformance with Municipal requirements. Grading will be accomplished to assure surface drainage is away from the new trench, The existing drainage pattern on the lot will not be affected dudng development. If the system Is constructed in accordance with our design the following statements apply: 1. The system, if constructed as designed, will have no adverse impact on the wells Lot 1, The Villages 'June 12, 2001 Page Two in the area or those to be constructed in the future. The system, if constructed as designed, will have no adverse impact on existing septic systems in the area or those to be constructed in the future. The system, if constructed as designed, will have no adverse impact on reserve space, either surface or subsurface, on any lots located in the area. The system, If constructed as designed, will have no adverse impact on drainage patterns in the area. The current drainage pattern will be maintained. Sincerely, Michael E. Anderson, P.E. Attachments ANDERSON ENGINEERING P.O. BOX 240773 ANCHORAGE, AK 99524 522-7T73 522-6779 (FAX) MEMORANDUM DATE: June 21, 2001 TO: Dan Roth FROM: Mike Anderson, P.E. SUBJECT: Lot 1, The Villages Subdivision Septic System Design Revision I have revised the location of the proposed absorption trench for Lot 1, The Villages Subdivision. The new location is outside the screening easement. I have also relocated the alternate site to the proximity of Test Hole No. 3. Please review the attached revised site plan and issue the p.e. rmit for construction of the new system. Thank you for your prompt review of this rews~on. VACANT THIS PROJ! ..Well Well We! Abs. ,nch j m · O -- m I LOT. 2. LOT 3 AREA MAP SCALE'1" = 100' ' P.r~ep~ed r4 TH2 w~th 'l Garage ,~OTE: t~ Insulate Over Under Driveway. F/owing Drainage 'SITE PLAN. Line 'SCALE 1" = 50' ' ' LOT 1, THE VILLAGES SUBDIVISION DESIGN FACTORS: SYSTEM REQUIREMENTS: Four Bedroom Home Peru. Rate: 10 Min./Inch Application Rate: .8 GPDISF 5' Wide Trench System 1,250 Gallon Septic Tank 4' Drainfield Rock 4 Bedrooms X 150 GPD 1.8 GPD/SF = 750 SF of Absorption Area 750 SFI5 LF (Width)*.5 (Red. Factor) = 75 LF Trench Length Therefore: Construct a 75' Long X 5' Wide X 4' Effective Depth Absorption Trench. Flowline Elevation in Trench to be 2' Below Original Ground Surface. Total Depth to be 6' Below Existing Ground. Mound Over Trench to Provide Minimum of 3' of Cover or Provide 2" of Direct Bury Insulation. 4!  4t' PVC ASTM D3034 D~ainfield Rock NOTE: TYPICAL WIDE TRENCH SECTION (NO SCALE) Grade Area Over Trench to Drain Away. Minimum 6' Separation From Bedrock. Minimum 10' Separation From Lot Line. Minimum 4' Separation From Groundwater. Minimum 100' Separation From Well. Performed For: Dave Tish Legal Description: Lot 1. The Villages Subdivision SLOPE North 5 6 1 11 12 13 14 15 16 17 18 OGIOL GM Municipali~ of ~chomge ~,~ 825 L Sb~t, ~chorage, AK 99502~650 SOILS LOG - P ERCO~ O N TEST Date Pedo~: SITE 21 South Was Groundwater Encountered? No S If Yes, What Depth? L Depth to Water O After Monitoring None P Date: 6/12/01 E Bottom of Hole See Site Plan 6% Reading Date Gross Net Depth To Net Time 13me Water Drop 9-Jun 11:44 3.5' 12:14 30 4.25" .75" 12:15 3.44" 12:45 30 4.12" .69' 12:46 3.5" 1:16 30 4.19" .69" Perc. Rate: 9 Min./Inch Perc. Hole Diameter:. 6' Test Run Between 4.5 Ft. and 5.5 FL Comments: Test Cavity was Presoaked Prior to Test. Performed By: ~ I, M3;J~ Certify That This Test Was Performed In Accordance With Ail State and Municipal Guidelines In Effect On This Date: 6/12/01 Performed For: Dave Tish Legal Description: Lot 1_ The Villages Subdivision 2 3 4 10 11 12 13 14 15 16 17 18 OGIOL GM/SM GM Gray 21 ..... Municipali~ of Anchorage ~ ~~ Depa~ent of Health & Human Se~s ~ ~. ~[ ~. ~[~sc~; ,~ ~ Date Pedo~: ~ SLOPE SITE P~N North South Was Groundwater Encountered? No If Yes, What Depth? Depth to Water After Monitoring None Date: 6117J01 Bottom of Hole See Site Plan S 6% 0 Reading Date Gross Net Depth To Net 'ime Time Water Drop 9-Jun 12:31 4.06' 1:01 30 7.44' 3.38" 1:02 4" 1:32 30 7.31' 3.31" 1:33 4.12" 2:03 30 7.38" 3.25" Pero. Rate: 9 MinJInch Perc. Hole Diameter:. 6' Test Run Between 5.5 FL and 6.5 FL Comments: Test Cavity was Presoaked Prior to Test. Performed By: ~ I, MLcjlaeLE..~:~ Certify That This Test Was Performed In Accordance With All State and Municipal Guidelines In Effect On This Date: 6/12/01 Municipality of Anchorage Department of Health & Human Services 825 L Street, Anchorage, AK 99502-0650 SOILS LOG - PERCOLATION TEST Performed For: Dave Tish Legal Description: Lot 1. The Villages Subdivision SLOPE North 9 10 11 12 OGIOL GM Gray 14 15 16 17 18 South Was Groundwater Encountered? No S If Yes, What Depth? L Depth lo Water O After Monitoring None P Date: 6/12/01 E Bottom of Hole 21 Date Performed: SITE PLAN See Site Plan 6% Reading Date Gross Net Depth To Net Time Time Water Drop 9-Jun 3:16 5.125" 3:46 30 8.375" 3.25' 3:51 5.19" 4:21 30 8.38" 3.19" 4:22 5.12' 4:52 30 8.25" 3.12' Perc. Rate: 10 Min./inch Perc. Hole Diameter: 6" Test Run Between 6 Ft. and 7 FL Comments: Test Cavity was Presoaked Prior to Test. Performed By: ~ I, ~ Codify That This Test Was Performed In Accordance With All State and Municipal Guidelines In Effect On This Date: 6/12/01 ON-SITE WASTEWATER DISPOSAL SYSTEM CONSTRUCTION AND MATERIAL SPECIFICATIONS SUBJECT: LOT 1, THE VILLAGES SUBDIVISION GENERAL: The scope of this project includes the procurement and placement of a new 1,2500-gallon septic tank at the location shown on the site plan. Work also includes the construction of a new 75' long X 5' wide X 4' effective depth absorption trench at the location shown. The distribution line in the trench will be placed at 2' below the existing ground surface. Total depth of the trench will be 6' below the existing ground surface. A minimum of 3' of cover is required above the absorption trench to protect against frost penetration. Ail components of the septic system must be placed a minimum of 100' from all wells in the area. Construction shall be in accordance with the approved site plan, design drawings, Municipal Permit with any special provisions or conditions, and all applicable State and Municipal Wastewater Disposal Regulations. The Contractor shall be responsible for obtaining all underground utility locates and for the layout of the septic system and verification of the location of all lot lines. Unless specifically agreed otherwise, the contractor shall be responsible for final grading areas subsequently depressed from soil settling. Property owner shall be responsible for revegetation of affected areas unless specifically agreed otherwise. Contractors installing wastewater disposal systems must be certified by the Municipal Department of Health and Human Services for system installations. Owners installing thei.r own syste.ms must receive prior approval from D.H.H.S. before beginning system installation. SEPTIC TANK INSTALLATION 1. A new 1,250-gallon septic tank must be procured from an approved source and installed at the location shown. A septic tank is to be constructed by a certified septic tank manufacturer. Construction shall include two 4" cleanouts for pumping access. The septic tank shall be sufficiently bedded to prevent settling or shifting of the tank. All standpipes on the septic tank shall extend a minimum of 12 inches above final grade. Tanks installed without 4' of cover shall have a minimum of 2" of direct budal insulation. Lot 1, The Villages June 12, 2001 Page 2 of 3 6. A foundation cleanout shall be installed one to four feet from the building foundation. Two cleanouts are required between the tank and the drainfield. 7. Final grading over the tank shall be such that a positive slope exists away from the septic tank. DRAINFIELD CONSTRUCTION: J The drainfield shall be constructed to the dimensions shown on the design. The bottom of the trench shall be within 2" of level. Distribution piping must be placed level with perforations down atop a level bed of drainfield rock. Rock should then be placed over the pipe to provide a minimum of 2" of cover. A silt barrier or geotextile fabric must be placed between the drainfield rock and the natural soil backfill. Monitor tubes must be 4" in diameter and installed at the locations shown on the design. The portion below ground must be perforated. Contractor shall vedfy the septic tank and drainfield are a minimum 100' away from any pdvate water wells in the area, 150' from a Class "C" Well or 200' from any community well. Direct bury insulation must .be placed over the distribution system if less than 3' of backfill depth ,s available. Finish grade over the trench must be mounded to prevent settlement or depressions. Grade area surrounding the absorption trenches to drain away. A minimum 2' of accepting soil is required below the drainfield rock for a 5' wide trench. Contractor shall vedfy this condition prior to placement of the rock. All pockets of unacceptable materials must be removed and replaced. MATERIAL SPECIFICATIONS: 1. Septic tanks must be constructed by a municipally approved septic tank manufacturer. The following pipe materials are approved for use in septic system installations in the Municipality of Anchorage: Cast Iron (perforated and solid) ASTM D3034 or P.V.C. (perforated and solid), ASTM F810 or H.D.P.E. (perforated, but not solid) and ASTM D2662 or A.B.S. (perforated and solid). Insulation shall be at least 2" thick extruded direct burial polystyrene (Dow Chemical Co. Styrofoam HI or equal). Septic tank inlets and outlets shall be fitted with watertight couplings (Caulder, Femco, or equal). Lot 1, The Villages June 12, 2001 Page 3 of 3 5. A permeable geotextile fabric (Typar, Mirafi or equal) must be installed between the final drain rock layer and the native soil layer. 6. Ail drain rock shall be .5" to 2.5" in diameter with less than 3% passing the #200 sieve. INSPECTIONS: Municipal Ordinance requires a minimum of two inspections. These inspections must be conducted under the supervision of a professional engineer registered in the State of Alaska. The first inspection must be conducted after the excavation of trenches, beds or pits and before the installation of any gravel. A septic tank may be set in place, but may not be backfilled. The second inspection must be conducted after the placement of the geotextile fabdc, gravel, distribution piping, standpipes, cleanouts and insulation. No backfill should be in place at the time of inspection. Contractor shall provide a copy of all field survey layout and construction notes for use in preparing the certified as-built of the completed system. Municipality of Anchorage Development Services Department Building Safety Division On-Site Water and Wastewater Program. · 4700 South Bragaw St. P.O. Box 196650 Anchorage, AK 99519-6650 www.ci.anchorage.ak.us (907) 343-7904 CERTIFICATE OF HEALTH AUTHORITY APPROVAL FOR A SINGLE FAMILY DWELLING Parcel I.D. 020-291-55 1. Expiration Date: 4:~ _ /.7( . ~) ~ GENERAL INFORMATION Complete legal description Lot t~ The Villaqes Location (site address or directions) V~lla.qes Scenic Parkway Current Property owner(s) David M. Tish Mailing address P.O. Box 1t3261 Anchora.qe, AK 99511 Lending agency Day phone 345.5798 Day phone Mailing address Real Estate Agent Day phone Mailing Address Unless otherwise requested, HAA will be held by DSD for pickup. 2. NUMBER OF BEDROOMS: Four(4) 3. TYPE OF WATER SUPPLY: Individual Well Individual Water Storage Community Class __ Public Water System Well TYPE OF WASTEWATER DISPOSAL: [] Individual On-site [] Individual Holding tank Community On-site [] Public Sewer The Municipality of Anchorage Development Services Department (DSD) Issues Certificates of Health .Authority Approval (HAA) based only upon the representations given in paragraph 5 by an independent professional civil engineer registered in the State of Alaska. Certificates of Health Authority Approval are required for the transfer of title (except between spouses) for properties served by a single family on-site wastewater disposal and/or water supply system. DSD also issues HAAs upon request to homeowners. Certificates of Health Authority Approval are valid for 90 days from the date of issue for properties served by a private or Class C well and may be reissued with new water sample results less than 30 days old. (Certificates may be reissued for a period of up to one year with valid water samples.) Certificates are valid for one year for propedies served by Class A or B wells or a public water system. The Municipality of Anchorage is not responsible for errors or omissions in the professional engineer's work. 4. STATEMENT OF INSPECTION BY ENGINEER As certified by my seal affixed hereto and as of the validation date shown below, I verify that my investigation, based on procedures outlined in the Health Authority Approval Guidelines for this application, shows that the on-site water supply and/or wastewater disposal system is(are) safe, functional and adequate for the number of bedrooms and type of structure indicated herein. I further verify that based on the information obtained from the Municipality of Anchorage files and from my investigation and inspection, the on-site water supply and/or wastewater disposal system is(are) in compliance with all applicable Municipal and State codes, ordinances, and regulations in effect at the time of installation. Name of Firm. Anderson En.qi~eerinfl Address P.O. Box 240773 Anchora.qe, AK 99524 Engineer's Pdnted Name Michael E. Anderson, P.E. 5. DSD SIGNATURE J Approved for ~ bedrooms. Disapproved. Phone 522.7773 Date 6/3/2002 · '..,.- - . Conditional approval for bedrooms, with the following stipulations: Additional Comments Attachments: HAA Checklist Septic System Advisory Well Flow Advisory Maintenance Agreements Supplemental Engineer's Report Other Original Certificate Date: Municipality of Anchorage Development Services Department Building Safety Division O~Site Water & Westewater Program 4700 South Bragaw St. P.O. Box 196650 Anchorage, AK 99519-6650 ~v.ci.anchorage.ak.us (9O?) 343-79O4 HEALTH AUTHORITY APPROVAL CHECKLIST WELL DATA Well type Private Date completed 6J26/2001 Total depth 267 ft. Date of test Static water level Well Ixeductton WATER SAMPLE RESULTS: C~Jform 0 celonies/100 mi. Date of sample: 5/29/2002 SEPTIC/HOLDING TANK DATA Tank Type/Material EeOc/Steel Tank s~ze tl250 gal. Foundation cieanout (Y/N) Y Date of pumping C. ABSORPTION FIELD DATA Date installed 6/25/2001 Length 00 Total depth 7_ f. Date of adequacy test If A, B, or C provide PWSID # Cased to 101 fl. FROM WELL LoG ~2 ft. 4 g.p.m. Nitrate 2.05 rog JI. Ca~ected by: MEA Number of Compartments _2 Pumper New Construction Pamel ID: 020-291-55 well Log (Y/N) Y Wh'es pmpedy protected (Y/N) Y Casing height (above ground) >24 AT INSPECTION g.p.m. iN. Date installed 6/22r2001 Cteanouts (Y/N) Y High water alarm (Y/N) .N Soil raUng (g.p.d./fl2 or ft2/bdrm) .8 GPD/SF System type Wide Trench ft. W*~th 5 ft. Gravel below pipe 4 ft. Eft. absorption ama 800 ft2 Monitoring tube Y Depre~___-!on over field N_ Results (Pass/Fail) For bedrooms Fluid depth in absorptk:m field before test in. Water added gal. New depth in. Elapsed T~me: min. Final fluid depth in. Absorption rate >= g.p.d. Any rejuvenaUon treatment (past 12 mo.) (Y/N & type) N If yes, give date D. UFT STATION Date instaJted 'Pump on' level at in. Datum E. SEPARATION DISTANCES Size in gallons 'Pump off' level at __in. Cycles tested Manhole/A_ _,?~_ _~ (Y/N) High water alarm level at Meets alarm & circuit requirements? SEPARATION DISTANCES FROM WELL ON LOT TO: Septic tank/lift station on lot >t00' Abserption field on lot >100' Public sewer main Sewer/septic sen~ce line >25' On adjacent lots >100' On adjacent lots >t00' Public sewer manhole/cleanout N/A Holding tank N/A. SEPARATION DISTANCES FROM SEPTIC/HOLDING TANK ON LOT TO: Building foundation >5' Properly line >5' Water main N/A Water sewice line >t0' Wells on adjacent lots >t00' SEPARATION DISTANCE FROM ABSORPTION FIELD ON LOT TO: Propely line >10' Water Service line >10' Curtain drain None Noted F. COMMENTS Building foundation >t0' Surface water >100' Wells on adjacent lots >100' Absorption field >5' Surface water >t00. Water main >t0' G. ENGINEER'S CERTIFICATION I certify that I have determined through field inspectione and mv~w of Municipal records that the above systems am in conformance with MOA HAA guidelines in effect on this date. Engineer's Printed Name Michael E. Anderson, P.E. Date 6/3/02 in. t~Y-31-O20Z:35P~ FROI~CT&E ENVIRO~NTAL SRV Zt~.~ CT&E Environ,nentalServlces Inc. 9075GI530T T-083 P.OZ/03 F-681 CT&£ Rtf~ 1023025001 Client Name Andiron Encmeeting Project ~am~ Lot 1, ~e VilI~R~ Client Sample ID ~T 1, ~e Villages Matrix ~inking Watrr Orde~d By PWSlD 0 Sample R~mar 'ks: ~atara DelinqUent Hilrate-N 2.O5 All Dates/Times are Alaska Standard Time Printed Date/Time 05/30/2002 16:47 Colleaed Datu'Tlme 05/29/2002 10:00 Received Date/Time 05/29/2002 12:30 Uniu Allowable prep Analysis Mahod Limits Date Date Init 0.200 mg/L EPA 300.0 (<10] 05/29/02 JDT laicrobiolo!r~ Laboratory Total C01ifonn col/I OOmL SMIS9992B 05/29/02 KAP Received T me May.3l. l:44Pbl ~Y-31-OZ 02:35~ FROJ~.-CTA£ ENVII~ON~NTAI. S~V 90'~SGIS~D1 T-OS] P.03/03 F-681 J GT&E Environmental Sewtc~ Inc. Tet: tgO"fl 541.2343 · · g Water Analysis Report for Total Coliform Bacteria ~ this W~ SAMPLE to U~ \\ \ IHt_ VILLAL;k3 3Ut~L)IVIblUI'I .... \\ \ . S 89'5T39" E 254.65' · - ~ '...-- .. ', ~ ~ ?:: ~' 1.g7 Acres ',.~....~o~...~. .. ~ ~ ~ -- ~ ~T~,~ · ~e[=,u,,.~.* " ~ ~ ' N 89'57 01 W 142.22 ~ S~O * ~P~G * P~G 2102 C~ S~ET ~L ~ (~243-~ ~O~E, ~ ~517 F~ ~B~T OF: LEG~DESC~ON: ~USION N~: It ~T 1 ~~of~ ~ ~GES S~D~ION ~T 9 8-92) ~. APRIL ~2, 2002 ~ M~ 3637 2001-21