Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
MCMAHON BLK 1 LT 4
McMahon Block i Lot 4 #017-041-45 On -Site Wastewater Disposal System Permit MUNICIPALITY OF ANCHORAGE Development Services Department On -Site Water & Wastewater Program 4700 Elmore Road, PO Box 196650 Anchorage, AK 99519-6650 Telephone: (907) 343-7904 Permit Number: OSP131429 Tax Code Number: 01704145000 Work Type: Septic Permit Effective Dates: November 22, 2013 to November 22, 2014 Design Engineer: ANDERSON CONSTRUCTION & ENG'G Subdivision: MCMAHON Site Legal Address: MCMAHON BLK 1 LT 4G:2835 Owner/Address: HLEIHIL LUYI & STACY 3750 E HUFFMAN ROAD ANCHORAGE AK 995162111 Site Mailing Address: 3750 HUFFMAN RD, Anchorage This permit is for the construction of: Y Disposal Field Y Septic Tank N Holding Tank N Privy All construction must be in accordance with: Lot Size in Sq Ft: 33925 Total Bedrooms: 5 N Private Well N Water Storage 1. The attached approved design. 2. All requirements specified in Anchorage Municipal code Chapters 15.55 and 15.65 and the State of Alaska Wastewater Disposal Regulations (18AAC72) and Drinking Water Regulations (18AAC80). 3. The wastewater code requires inspections during the installation. The engineer must notify the Development Services Department at least 2 hours prior to each inspection. Provide notification by calling (907) 343-7904 (24 hours). 4. From October 15 to April 15, a subsurface soil absorption system under construction during freezing weather must either: A. Open and Close on the same day. B. Covered, sealed, and heated to prevent freezing. Special Provisions: PRIOR TO CONSTRUCTION: Additional testholes shall be completed to verify the design. Results shall be submitted with the final inspection report. Received Issued By Municipality of Anchorage menr if P.O. Box 196650 • 4700 Elmore Road y _ Anchorage. Alaska 99519-6650 • (907) 343-7904 • Fax (907) 343-7997 Department hftp://www.muni.org/Onsite Development Services Division On -Site Water and Wastewater Program **** VARIANCE/WAIVER REVIEW **** Waiver#: OSP131430 COSA#: Permit#:OSP131429 PID#:017-041-45 Legal Description: McMahon, Block 1. Lot 4 Engineer: Mike N. Anderson Applicant: Luvi Hleihil Your request for a waiver of the required 10 feet horizontal separation from the absorption field to the property line has been approved. The approved separation distance is 2.0 feet. This waiver approval applies to the proposed absorption field only. Any future upgrade to the on-site wastewater disposal system will require all separation distances be met or another approval from this department. ® The affected adjacent property owner(s) have been given a 7 day notice regarding this waiver. ❑ Notarized letter(s) of non -objection have been received from the owner(s) of the affected adjacent property. ❑ Adjacent properties are not affected by this waiver. ................................................•.............................1 Waiver is Granted: X Waiver is not Grante(d/:: Date: a� %3 Approved �`' Name of Reviewer ................................................................................ Rec#: Amount: $200.00 Date Paid: 11!712013 **** VARIANCE/WAIVER REVIEW **** MUNICIPALITY OF ANCHORAGE Community Development Department Phone: 907-343-7904 Development Services Division Fax: 907-343-7997 On -Site Water & Wastewater Program ON-SITE SEWER/WELL PERMIT APPLICATION Parcel I.D. d(7 - D t-(( t--! /� I e �,' l Property owner(s) C'L ti i i Day phone Mailing address Site address 37 13 o Legal description (Sub'd., Block & Lot) _M Legal description (Township, Range & Section) Lot Size 3 75 9 2 S Sq. Ft. APPLICATION IS FOR: (® all that apply) Absorption Field F Septic Tank [Z Holding Tank ❑ Privy ❑ Private Well ❑ Water Storage ❑ Number of Bedrooms 5___ APPLICATION IS AN: TYPE OF DWELLING: Initial ❑ Single Family (SF) ❑ (w/wo ADU) Upgrade 125-D ❑ Renewal E] Duplex (D) Multiple Dwellings ❑ (SF and/or D) THIS APPLICATION INCLUDES A VARIANCE / WAIVER REQUEST FOR: r vb �tn-c. VVttt-rr Distance: Z I certify that the above information is correct. I further certify that this is in accordance with applicable Municipal Codes. nature of property owner or Permit/Rush Fees: Date of Payment: Receipt Number: Permit No. 05 /3 I'{ az) Permit App_ ;L.,k. Waiver Fees: Ow 3S^ Date of Payment: I1I-I I k--!) C�� 43,to Receipt Number: ll/I Waiver No. Michael N. Anderson, P.E. Civil/Structural Engineering & Construction 4661 Natrona Avenue Anchorage, Alaska 99516 Phone 345-3377 Fax 345-1391 Nov 5, 2013 Municipalities of Anchorage Departments of Health and Human Services P.O. Box 196650 Anchorage, Alaska 99519-6650 Fax 249-7847 Re: McMahon Subd. Blk 1, Lot 4 To Whom it may concern: This is a request for a new septic permit on the above referenced lot because the owner is adding two more bedrooms for a total of five. Two test holes were excavated north and west of the old septic area, see site plan. The soils in the two test holes consisted of various layers of sandy and silty sands throughout the entire test hole depth. No water was observed during the excavation or after the 7 day monitoring period. A new simple deep trench was designed with 8.5 feet of effective depth has been proposed with a new 1500 gallon tank. The perc rate was 45 minutes per inch but the secondary test hole Pere was 2 minutes per inch which required the secondary trench t,qbe 44 long by 7 feet effective. We are requesting a lot line waiver ofp"feet on the northeast corner of the lot. The justification is it's the best location for the system and will not impact any of the neighboring properties. The lot slopes gently downhill to the north at about 1 percent with no cut banks or slopes greater than 25 percent within 150 feet of the site. The lot is large and this new system will not impact any of the neighboring lots. Please call me if you have any questions. Sincerely Michael N. Anderson, P.E. BACKFILL EXISITNG TRENCH W/ NATURAL MATERIAL FOR MIN 16' BETWEEN TRENCHES RESERVE SYSTEM 1.2GPD/SF, 7 FEET EFF. 44' LONG x- 0% — NEW TEST HOLE REQUIRED DURING CONSTRUCTION TO VERIFY EXISTING SOILS II EXISTING SEPTIC TO I I ' E ABANDONED � 2' CONTOURS TYP II y 1% ii II I�o\1`1 EXISTING SEPTIC T0� \-+ U -+ BE ABAND NED T- PROPERTY LINE L___i__J �11Py OR NEW 1,500 GALLON - SEPTIC TANK EXISTING HOUSE Septic Design Prepared for LUYI HLEIHIL McMAHON SUBD BLK 1, LOT 4 Anchorage, Alaska Michael N. Anderson,P.E. DATE: 4661 NATRONA DRIVE DRAWN: ANCHORAGE, ALASKA 99516 345-3377 / FAX: 345-1391 SCALE: 00-1% EXISTING TANK WELL 11/6/2013 DJR 1 "=30' LOT LINE WAIVER REQUESTED FOR 2 FEET OLD TEST HOLE BY MINA I � SEPTIC I 1 \ r 11" DESIGN CRITERIA: MOUND OVER (TH#2) (TH#1) q GRADE 5 BDRM X 150 = 750 GPD 10 ORG SOILS = 750/0.45 = 1667 GPD 10 ORG 9SEW 1667 GA/19 = 98 TER FABRIC -a.5PIPE (1) TRENCH SM/SP SM/SP ER ROCK 12.0' DEEP 8.5' EFFECTIVE -13.0 2.0' WIDE 2.0' 98' LONG 19 19 SEPTIC FIELD SECTION HUFFMAN ROAD - --- -_-- ` --PROPOSED-NEW -- -- 5 BEDROOM PROPOSED REPLAT SYSTEM LOT LINE _ 10ELECT �n ` I y EASEMENT t I I SEPTIC EXISTING HOUSE K _ _ PROPERTY LINE SEPTIC WE�L I 10' UTILFfY� I EASEMENT I - -' II Septic Design Prepared for 11 OF LUYI HLEIHIL ���P�E q0 McMAHON SUBD BLK 1, LOT 4 Anchorage, Alaska ■`..... ;'.....gTM .......'•�i ................. 0 0......... i "'.MICHAEL N. ANDERSON: Michael N. Anderson P.E. 4661 NATRONA DRIVE ANCHORAGE, ALASKA 99516 DATE: DRAWN: 11/6/2013 DJR ♦ G) : a # No. C,� 9�b69 �1 2j1//�1•` 345-3377 / FAX: 345-1391 SCALE: 1"=100'+��t�SS,��i••� 01 Municipality of Anchorage Development Services Department Building Safety Division On -Site Water and Wastewater Program 4700 Elmore Road P.O. Box 196650 Anchorage, AK 99507 www. ci. a ncho rage.ak. us (907) 343-7904 Soils Log 7rcolation Test Performed For: r L � 1 'l -P rLp Date Perk Legal Description: /Vj . 'r f4 ✓1p% I^V Township, Range, Section: l Slope �v Depth (Feet) ✓ ° 5 4� �✓ g 1.2 11 1 fVA � �4fSP UA\rt, v. 5 / WAS GROUNDWATER r� V at'LENCOUNTERED? V 5 IF YES, AT WHAT DEPTH? E Depth to Water After O P Monitoring? V N C- E Date:1 5 V;t 0 d P d c�J k?. fT e 49tH° a o�•YJ" e./.~Q cos. e... ()r-�:5v, 20 Site Plan r lDr_ re 4.2& 1( , — sti VA. nA. M . PERCOLATION RATE 646 (minute.Anch) PERC HOLE DIAMETER io TrLST(/pUN BETWEEN � FT AND �I� 'FT .1 1� ('04 y15 — Sr. rig ICA N1'Uw . PERFORMED BY: i/1 I k f— Al I CERTIFY THAT THIS TESTIWA4 PERFORMED IN ACCORDANCE WITH ALLSTATE AND MUNICIPAL GUIDELINES IN EFFECT ON THIS DATE. DATE: —(I (� NICHAEL N. ANDERSCN : - CE/94,69 e 5 Y It ti ()r-�:5v, 20 Site Plan r lDr_ re 4.2& 1( , — sti VA. nA. M . PERCOLATION RATE 646 (minute.Anch) PERC HOLE DIAMETER io TrLST(/pUN BETWEEN � FT AND �I� 'FT .1 1� ('04 y15 — Sr. rig ICA N1'Uw . PERFORMED BY: i/1 I k f— Al I CERTIFY THAT THIS TESTIWA4 PERFORMED IN ACCORDANCE WITH ALLSTATE AND MUNICIPAL GUIDELINES IN EFFECT ON THIS DATE. DATE: —(I (� Municipality of Anchorage Development Services Department Building Safety Division On -Site Water and Wastewater Program 4700 Elmore Road P.O. Box 196650 Anchorage, AK 99507 www. ci. anchoraoe.ak. us (907) 343-7904 Soils Log - Percolation Test Performed For: G y .1 r r� ��i/ r yt , Date Performed: Legal Description: -y�Nir 140t k uvt�I�L V��� Township,I Range, Section_ Slope I I I I I 1 _ tl.rcr �I G h 2- 3- 4 mll� P L- 04 -tJS. 11 COMMENTS WAS GROUND WATER ENCOUNTERED? (� 5 IF YES, AT WHAT DEPTH? f Depth to Water After r D uP Monitoring? E Date: (/ GF Jk MICHAEL N. ANDERSON :rtC. 69 Site Plan D.... 41.. A, _ Reading Date Gross Time Net Time Depth to Water Net Drop It rt i b rr n PERCOLATION RATE Z (minuWfinch) PERC HOLE DIAMETER is TEST RUN BETWEEN FT AND FT PERFORMED BY: mli 41 I CERTIFY THAT THIS TEST W S PERFORMED IN ACCORDANCE WITH ALLSTATE AND MUNICIPAL GUIDELINES IN EFFECT ON THIS DATE. DATE: // G Municipality of Anchorage A' ° Development Services Department r Building Safety Division On-Site Water and Wastewater Program, 4700 Elmore Road P.O. Box 196650 Anchorage, AK 99507 Page of www.ci.anchorage.ak.us (907) 343-7904 ON-SITE WASTEWATER DISPOSAL SYSTEM AND/OR WELL INSPECTION REPORT Permit Number: SW000152 PID Number: 017-041-45 Name: JIM McAfee Wastewater System: ❑ New © Upgrade Address: 3750 Huffman Rd ABSORPTION FIELD Phone: Number of Bedrooms: 3 17 Deep Trench ❑ Shallow Trench ❑ Bed ❑ Mound ❑ Other: LEGAL DESCRIPTION Soil Rating: Total Depth from original grade: 0.8 GPD/Fe 10.1 Ft. Block:1 Lot: 4 Subdivision: McMahon Depth to pipe bottom from anginal grade: Gravel depth beneath pipe: 4.0 Ft. 6.1 Ft. Township: Range: Section: Fill added above original grade: Gravel Length: 0.5 Ft. 53 Ft. Well: El New Upgrade ❑ Gravel width: Number of lines: Distance between lines: 2.0 Ft. 1 X Ft. Classification (Private, A, B, C): Total Depth: Cased to: Total absorption area: Pipe Material: Ft. Ft 636 Ft= 3034 Driller: Date Drilled: Static Water Level: Installer. Date Installed: Ft. MNA 6-13-00 Yield: Pump Set at: Casing Height Above Ground: GPM Ft. Fc TANK SEPARATION DISTANCES ® Septic ❑ Holding ❑ S.T.E.P. ❑ Other: To Septic Absorption Lift Holding ublic/Private Manufacturer: Capacity: From Tank Field Station Tank Sewer Line Anch Tank 1000 Gal. Well >100' >100' x x 50' Material: Steel Number of Compartments: 2 Surface Water >100' >100' X x LIFT STATION Lot Line 35' 18' X X Size: XX Gal. Manufacturer: XX Foundation 30' 60' "Pump on" level at: "Pump off' level at: High water alarm at: x x XX in. XX in. XX in. Curtain Drain none none X x Pump Make & Model Electrical Inspections performed by: XX XX Remarks: BENCH MARK Location and Description: Garage slab Assumed Elevation: 100 Ft Inspections performed by: George McFly (MNA) Dates: 1St 6-13-00,6pm .,'�°!"I d 2nd 6-13-00,8pm ���� • • • .... ,OF Development Services Department Approval `''••°� 0 49Lm_ P • j Conditional Approval Date: ®/ MICHAEL N. ANDERSCN•:, Po -;0 Reviewed and approved by: Date:���©•r�ES`� CE- (Rev. 04/06) ®®®p\"S 11 �° Permit No. SW000152 Page 2 of 2 Municipality of Anchorage DEPARTMENT OF HEALTH AND HUMAN SERVICES ENVIRONMENTAL SERVICES DIVISION P.O. Box 196650 Anchorage, Alaska 99519-6650 Telephone: 343-4744 On—Site Wastewater Disposal System and/or Well Inspection Report Legal Description: LOT 4, BILK 1 McMAHON S/D PID No.: 017-041-45 MARK A B GRND. PIPE / \ ELEV. 100.1 ELEV. 96.2 1 \ 1 FCO 43 20 Col TC01 63 66 28 33 99.7 99.7 96 1 1 TCO2 71 40 99.9 C05 T I CO2 73 4399.9 95.4 _ CO3 VAVLE 74 75 43 44 99.7 99.7 _ 95.4 CONCRETE R NG W ROCK � C04 96 60 9.2 19.5 95 \ _ _ , COy C05 80 82 9.5 95.1 cr MT 181 79 o 1 —� 0 0 CO2 0 0 TC01 r-) BENCH, CONCRETE S B ELEV. 100 L--� —J o 0 TCO2 4 O \ O Col cv O N N L �� / N I`7 A �� B �i N 0 / 0 HOUSE —x—x—x—x M W 0 / OLD TANK MPED AND CRUSHED N 0 // O O O O 0 / Z I Z z.1 � / I 1 I 1 I 1 I I I I I WELL I I I I ASBUILT 1\ \ SCALE: 1"=30' \ 0.1 FCO -CO1 TC01 TCO2 Or 1 CO2 CO3 VALVE 1��•� I 99.7 MT1 C05 .6 99..•�. 11`p�, • qs��� • ♦ TH 4 ♦♦♦ -1 orF N6UlATl WHERE REQUIREDABRIC LLFLMR •! 6.2 ' 1,000 GALLON STEEL TANK 9 .4 "�°'�`" • " • "•"""""" ""� •��� •' , �♦ -:MICHAEL N. ANDERSON;= 91 91 ♦ ��' No. E 9 69 • ♦•. K • / ��..••� V ♦♦••• S• SEPTIC SECTION . .11 44I \..11 N.T.S. -B3.1 MUNICIPALITY OF ANCHORAGE Department of Health and Human Services On -Site Services Program 825 L Street, Room 502 P O Box 196650, Anchorage, AK 99519-6650 (907) 343-4744 ONSITE WASTEWATER DISPOSAL SYSTEM PERMIT Upgrade Permit Number SW000152 Legal Descnption MCMAHON BLK 1 LT 4 Design Engineer 0088 Anderson Construction & Eng'g Owner Name James McAfee Owner Address 3750 Huffman Rd Anchorage , AK 99516-2111 1 vn,nrlQr-h011q C01 t31n06&Pee-, 40113100 Date Issued Jun 07, 2000 Expiration Date Jun 07, 2001 Parcel ID 017-041-45 Site Address 003750 HUFFMAN RD Lot Size 33925 SQ FT Total Bedrooms 3 Permit Bedrooms 3 This permit is for the construction of ❑✓ Disposal Field ❑✓ Septic Tank ❑ Holding Tank ❑ Privy ❑ Private Well ❑ Water Storage All construction must be in accordance with 1 The attached approved design 2 All requirements specified in Anchorage Municipal Code Chapters 15 55 and 15 65 and the State of Alaska Wastewater Disposal Regulations (18AAC72) and Drinking Water Regulations (18AAC80 ) 3 The engineer must notify DHHS at least 2 hours pnor to each inspection Provide notification by calling (907) 343-4744 ( 24 hours ) ( Not required for a Water Supply Permit only ) 4 From October 15 to April 15, a subsurface soil absorption system under construction during freezing weather must be either A Open and closed on the same day B Covered, sealed, and heated to prevent freezing Received By Issued By LtJ Date 6 44"' Date co —1;2,_0 0 l ter« Michael N. Anderson, P.E. 4640 Shoshom Avenue Anchorage, Alaska 99516 Phone 345-3377 Fax 345-1391 June 6, 2000 Department of Health and Human Services P O Box 6650 Anchorage, Alaska 99519-6650 Re Lot 4 Block 1 McMahon Subd To Whom it may concern The above property has an existing septic system in failure A test hole was excavated and found to have silty sand to 17 feet, with the stiffer material below twelve feet No water was discovered at the time of excavation or after the seven day monitoring period The perc was 2 minutes per inch at elevation -5 feet however due to the still soils and layered strata a slower perc will be used for back-up The design perc will be in the 5 to 15 minute range The surrounding properties will not be impacted by this new system and the old tank will be replaced due to its age The lot slopes gently to the north (Huffman Road) If you have any question please call me at 345-3377 Smcerel chael Anderson, P E MOUND OVER DESIGN CRITERIA: o GRADE 3 BDRM X 150 = 450 GPDoR SOILS = 450/0 8 = 562 SQ FT REQ'D o FILTER FABRIC 562/12 — 47' USE 50' TRENCH. a 9.0' DEEP 6.0' EFFECTIVE sM 2.0' WIDE 50' LONG 2 0' DRAIN ROCK -16' — H U F F M A N R 0 A D- 10' UTILITY EASEMENT '%\ I I TH �1 NEW I I i I SYSTEM I I EXISTING CRIB I I _ II ,EXISTING HOUSE i i \i i I � 11 li I 10' UTILITY EASEMENT 4 --- --------- ----- --- ----L--- ------- ---- ---- — — — — — — — II ------------ ----- EXISTING WELL /EXISTING II ADJACENT WELL I I SEPTIC DESIGN PREPARED FOR F JAMES McAFEE gF 0 •Al-qXk LOT 4, BLOCK 1, ,?"��°:••••••• .• s�p�d McMAHON SUBDIVISION :4 TFir ••;�t� r• ... .... PREPARED BY MICHAEL N ANDERSON, P E ••••••••••• 4640 SHOSHONI AVE i� �•,• MICHAEL N ANOERSCN : �27 �� CE -9869 (907) 345-3377 / FAX (907) 345-1391 � ,d1 SOP �lO0r)-q SCALE 1 "=8D' MAY 17, 2000 `w �� f FES.i� •NI - H U F F M A N R 0 A D- 10' UTILITY EASEMENT --- -------- -- ----...--------- i CO MONITORING TUBE TH#1 ` NEW SYSTEM Y -C iy -- --- O DIVERTER EXISTING EPTIC CO NEW 1,000 GALLON - ------------ o SEPTIC TAN ---------------- 0 G O ,---- -- EXISTING TA K TO ABANDONED co ' ' EXISTING SINGLE .\ FAMILY RESIDENCE i i I i � I I � I � I I I I � I � I � I I � � I � — — — — — — — —'r — — — — — — — — — ^ — — — — — — — — SEPTIC DESIGN PREPARED FOR JAMES McAFEE LOT 4, BLOCK 1, �?•' +/ McMAHON SUBDIVISION r t •y 491M PREPARED BY MICHAEL N ANDERSON, P E , 4640 SHOSHONI AVE • MICHAEL N ANDERSON / (907) 345-3377 / FAX (907) 345-1391 '9 •;w l� �•, CE --9469,: 3Fp of.G�B� "=30' SCALE 1 MAY 12, 2000+@l ary p�70hszo9 k Municipality of Anchorage DEPARTMENT OF HEALTH 8, HUMAN SERVICES 825 "L" Street Anchorage, Alaska 99502-0650 SOILS LOG — PERCOLATION TEST .� • J�!r.4r�% A�ta ii 9 T Vi +r•• MICHAEL N A�ND[RSON p 0 PERFORMED FOR 'l`..,_-��, �V( �1.ze/ DATE PERFORMED LEGAL DESCRIPTION < <I(3 l Md1Mn n0✓7 Township, Range, Section DEPTH SLOPE SITE PLAN (FEET) 1= 2- 3- 4- 5 - 6- 7 - 8. 9. 10� 11 12 13 14 15 1& 17 18 19 20 -itNl, 5,14-y ,mI tpcaP—s- yoe{ FETTI VL "C— WAS GROUNDWATER O Sr T ENCOUNTERED? S IF YES AT WHAT L O DEPTH? P E Depth to Wier After / 00 MOeAmtng? gem e� Olt& o I. µe(c' PERCOLATION RATE ' Iminutevmchl PERC HOLE DIAMETER TEST RUN BETWEEN &f FT AND 57FT _ —% —.-. .f... � t.�. 5-4. CL � V( lel i :OMMENTS ��c.tal.w�r SNS:•..�n PERFORMED BY /yil[J'-rtrnn I ACCORDANCE WITH ALL STATE AND MUNICIPAL GUIDELINE a r 72-0081Rev 41851 DrCb CERTIFY THAT THIS TEST WAS PERFORMED IN S IN EFFECT ON THIS DATE DATE Cj f2'3�/OD a GAAB-HD-I Gf"'�%R ANCHORAGE AREA BOROL�`ti, DLrmtiTMENT OF ENVIRONMENTAL QUALI'i r 3500 TUDOR ROAD ANCHORAGE, ALASKA 99507 279-8686 INSPECTION REPORT ON-SITE SEWAGE DISPOSAL SYSTEM --7.5;e© -- MAILING NAME ��� �ii�l_� .6,/---g % " ADDRE S 17 / �/�1P�`��l/Gf� ._PHONES ,9 LOCATION LEGAL DESCRIPTION SEPTIC TANK: NUMBER OF DISTANCE FROM WELLy�®/ MATERIAL s%-�� COMPARTMENTS D LIQUID CAPACITY f -Z -5Z GALLONS. INSIDE LENGTH t/ INSIDE WIDTH DEPTH SEEPAGE SYSTEM: SEEPAGE PIT: NUMBER OF PITS OUTSIDE DIAMETER Lam' WIDTH , LENGTH ', DEPTH LINING MATERIAL �� �%�-����//�Gf . DISTANCE FROM WELL Z/,2,Q/ BUILDING FOUNDAj[QN---L-:ep/ NEAREST LOT LINE ���`��' '�D TOTAL EFFECTIVE ABSORPTION AREA (WALL AREA) ` SQ. FT. TILE DRAIN FIELD: /v�/� DISTANCE FROM WELL NUMBER OF LINES ABSORPTIO FOUNDATION NEAREST LOT LINE_ CE BETWEEN LINES TRENCH WIDTH FT. LENGTH OF EACH UNE __7_ - TOTAL LENGTH OF LINES IN. TOTAL EFFECTIVE DEPTH: TOP OF TILE TO FINISH GRADE DEPTH OF FILTER MATERIAL BENEATH TILE IN. ABOVE TILE WELL:'� 491101�7 i DISTANCE FROM WATER TYPV2!9 �✓-y-'e � DEPTH BUILDING FOUNDATION. SAMPLE NEAREST i NEAREST SEPTIC i SEEPAGE i _ OTHER LOT LINE SEWER LINE TANK .S�D 7L SYSTEM CESSPOOL '� SOURCES�.yO,' 6W DISTANCES: DIAGRAM OF SYSTEM s� h - m F. DATE 1224_ZLp2z G.A.A.B. GREAT ER ANCHORAGE AREA BOROUGH DEPARTMENT OF ENVIRONMENTAL QUALITY ( 3500 TUDOR ROAD POUCH 6-650 ANCHORAGE, ALASKA 99502 ' TELEPHONE 279-8686 NAME OF APPLICANT INSTALLATION LOCATION LEGAL DESCRIPTION SEWAGE DISPOSAL SYSTEM - APPLICATION AND PERMIT /-07- .0 0/ f 4V PERMIT NO. INSTALLATION OF: SEPTIC TANK SEEPAGE PIT, DRAIN FIELD , OTHER , TYPE AND SIZE OF FACILITY TOBB EEE SERVED /�/q�, g/-eR - FINANCED THROUGH u zV� TO BE INSTALLED BY `� " � c- -..... W^I W. Twl¢ ww=mIT m mnv VAI in WIT54fillT Snit_ T'FST COMPLETION DATE ANTICIPATED FINAL INSPECTION. 24 HOUR NOTICE REQUIRED. BACKFILLING OF ANY SYSTEM WITHOUT FINAL INSPECTION BY THE HEALTH DEPARTMENT AUTHORITY WILL BE SUBJECT TO PROSECUTION. SEPTIC TANK SIZE TYPE Skez-XSEEPAGE AREA SIZE TYPE MINIMUM DISTANCES. REQUIREMENTS r- DIAGRAM OF SYSTEM /Y7(J7 FOUNDATION TO SEPTIC TANK `' FOUNDATION TO SEEPAGE PIT® DRAIN FIELD , /�5 SEPTIC TANK TO SEEPAGE PIT WALL SEPTIC TANK , SEEPAGE PIT, DRAIN FIELD TO NEAREST LOT LINE. WELL TO SEPTIC TANK ��✓' SEEPAGE PIT DRAIN FIELD WATER MAIN TO SEPTIC TANK DRAIN FIELD d� SEPTIC TANK, TO RIVER, LAKE, STREAM. ALSO CONSIDER AREA WELLS. SEEPAGE PIT ~� SEEPAGE PIT DRAIN FIELD CAST IRON INTO AND OUT OF SEPTIC TANK AND INTO CRIB CROSSING GAP EXCAVATION 5 FEET INTO UNDISTURBED SOIL. 4 INCH DIAMETER CAST IRON SIPHON PIPES ON SEPTIC TANK AND SEEPAGE FITTED WITH AIRTIGHT REMOVABLE CAPS. GRAVEL BACKFILL CONFORM TO BOROUGH REGULATIONS REGARDING INSTALLATION. / V LTH AUTHORITY OR LICENSED DESIGNER I CERTIFY THAT I AM FAMILIAR WITH THE REQUIREMENTS OF GREATER ANCHORAGE AREA BOROUGH ORDINANCE NO. 28-68 AND THAT THE ABOVE DESCRIBED SYSTEM IS IN ACCORDANCE WITH SAID CODE. if N DATE APPLICANT'S SIGNATURE GREATER ANCHORAGE AREA BOROUGH Department of Environmental Quality 3500 Tudor Road, Anchorage, Alaska 99507 279-8686 Date Received / Time of Inspection Date of Inspection�� REQUEST FOR APPROVAL OF INDIVIDUAL SEWER & `MATER FACILITIES FOR 1. Approval Requested By: Address: 2. Property Owner: 3. Legal Description: Phone: honeoZ 4. Location: i 5, Type of Facility to be Inspected:y� Number of Bedrooms: 6. Well Data:--� A. Type,�'�Iid �i1��� B. r C. Construction D. 7, Sewage Disposal System: i Depth Bacterial Analysis A. Installed /0) Installer,,Z�4/AB4e" ,�U/G��✓ 1_,-<. -Septic Tank: 1. Size ,2571 2, Manufacturer D. Seepage Pit: 1. Size,-2,22}(���/ 2, Material E. Disposal Field: Total. Length of Lines ll� B. Distances: A. Well To: Septic Tank Absorption Area Sewer Lines Nearest Lot Liner WD�2cC, Other Contamination B. Foundation to Septic Tank /,S7 ", Absorption Area C. Absorption Area to Nearest Lot Line t F GREATER ANCHORAGE AREA BOROUGH Department of Environmental Quality 3500 Tudor Road, Anchorage, Alaska 99507 279-8686 Date Received / Time of Inspection Date of Inspection�� REQUEST FOR APPROVAL OF INDIVIDUAL SEWER & `MATER FACILITIES FOR 1. Approval Requested By: Address: 2. Property Owner: 3. Legal Description: Phone: honeoZ 4. Location: i 5, Type of Facility to be Inspected:y� Number of Bedrooms: 6. Well Data:--� A. Type,�'�Iid �i1��� B. r C. Construction D. 7, Sewage Disposal System: i Depth Bacterial Analysis A. Installed /0) Installer,,Z�4/AB4e" ,�U/G��✓ 1_,-<. -Septic Tank: 1. Size ,2571 2, Manufacturer D. Seepage Pit: 1. Size,-2,22}(���/ 2, Material E. Disposal Field: Total. Length of Lines ll� B. Distances: A. Well To: Septic Tank Absorption Area Sewer Lines Nearest Lot Liner WD�2cC, Other Contamination B. Foundation to Septic Tank /,S7 ", Absorption Area C. Absorption Area to Nearest Lot Line Reque t for Approval of idual Page Tyro 9:1" Comments: i' Annroved 4155z�, Disappr Sewer & Water Facilititi- Date Approval Valid for One Year From Date Signed Greater Anchorage Area Borough, Department of Environmental Quality DIAGRAM OF SYSTEM I certify that the information contained in this request for approval to be a true and accurate representation of the subiect sewer and water facilities located at: Signed Date Municipality of Anchorage*AE • Development Services Department Building Safety Division On -Site Water and Wastewater Program 4700 Elmore Street P.O. Box 196650 Anchorage, AK 99519-6650 www.muni.org/onsite (907) 343-7904 CERTIFICATE OF ON-SITE SYSTEMS APPROVAL FORA SINGLE FAMILY DWELLING Parcel I.D. COSA # O 5 C- u 101_ Expiration Date: ' 1. GENERAL INFORMATION Complete legal description IAZ: Ma -5& Location (site address) '5? so l-�„� ,,,�,,� p . Current Property owners) Day phone 3 Y S -'3vS Mailing address Lending agency Day phone Mailing address Real Estate Agent Day phone Mailing Address Unless. otherwise requested, COSA will be held by DSD forpickup. 2. NUMBER OF13EDRobvip: 3 -3.-T-YR-E—OF—MIATER-SU:P-P-LX: _ ___ __ _ _ _TYP-E-OF-WASTEWATER-DISPOSAL:. i Individual Well ( Individual On-site Individual Wafer Storage ❑ Individual Holding .Tank ❑ Community Class` Well ❑ Community On-site ❑ Public Water System ❑ Public Sewer ❑ The Municipality of Anchorage Development Services Department (DSD) issues Certificates of On -Site Systems Approval (COSA) based only upon the representations given in paragraph 4 by an independent. professional civil engineer registered in the State of Alaska. Certificates of On -Site Systems Approval are required for the transfer of title (except between spouses) for properties served by a single-family on-site wastewater disposal and/or water supply system. DSD also issues COSAs upon request to homeowners. Certificates of On -Site Systems Approval are valid for 90 days from the date of issue for properties served by a private or Class C well and may be reissued with new water sample results. (Certificates may be reissued for a period of up to one year with valid water samples.) Certificates are valid for one year for properties served by Class A or B wells or a public water system. The Municipality of Anchorage is not responsible for errors or omissions in the professional engineer's work. 4. STATEMENT OF INSPECTION BY ENGINEER As certified by my seal affixed hereto and as of the validation date shown below, I verify that my. investigation, based on procedures outlined in the Certificate of On -Site Systems Approval Guidelines for this application, shows that the on-site water supply and/or wastewater disposal. system is (are) safe, functional and adequate for the number of bedrooms and type of structure indicated herein. I further verify that based on the information obtained from the Municipality of Anchorage files and from my investigation and inspection, the on-site water supply and/or wastewater disposal system is(are) in compliance with all applicable Municipal and State codes, ordinances, and regulations in effect at the time of installation. Name of Firm "(?A pz-� /-(,4k d P. C . Phone 5-6-- 3 3 -7 - Address HL 4 r n1o1jr(r,,- Engineer's Printed Name 5. DSD SIGNATURE Approved for !— bedrooms. Disapproved: Date r bVI, r �/ •lyo T.� y CC e i y d. ®IPJ /�••�••• • Ik 'M, 09•• s o e •s�' �••• •goo a ••• oeo•e••°�s ® MICHAEL N. AND:RSC J .* rk7 r,9 . �+o . v,s Conditional approval for bedrooms, with the following stipulations: Attachments: COSA Checklist X Septic System Advisory Well Flow Advisory Nitrate Advisory PROGRAM J�l. oia a' i � • • �.SO��1\ Arsenic Advisory Maintenance Agreements Supplemental Engineer's Report Other _ By: Original Certificate Date: 1 �� g f (Rev. 11/05) Municipality of Anchorage • "'� Development Services Department Building Safety Division O"n-Site Water & Wastewater Program 4700 Elmore Street P.O. Box 196650 Anchorage, AK 99519-6650 www.muni.org/onsite (907) 343-7904 CERTIFICATE OF ON-SITE SYSTEMS APPROVAL CHECKLIST Legal Description: /Yl'f.' /k4 4 (uvl Lq Parcel ID: Cil% — o `f( -q�g_ A. WELL DATA Well type � C- If A, B, or C provide PWSID # Date completed t4h knv10,1 Sanitary seal (Y/N) Total depth IN ft. Cased to 7-,9 oft. , FROM WELL LOG Date of test Static water level ft. Well production g.p.m. WATER SAMPLE RESULTS: 2 Coliform —1--Colonies/100 mL Nitrate CP, S�g/L Arsenic: ug/L date of sample: (2 z T/c B. SEPTIC/HOLDING TANK DATA Tank Type/Material 5 �--Ir r(. Tank size (Poo gal. Number of Compartments 'Z - Foundation cleanout (Y/N) Y Depression over tank (Y/N) N Well Log (Y/N) *'& [ 0 Wires properly protected (Y/N) Y_ Casing height (above ground) in. AT INSPECTION 9-13-m- IL Other bacteria colonies/100 mL Collected by: Date installed L l r3��, o Cleanouts (Y/N) Y High water alarm (Y/N) Date of pumping I Pumper X r oo# & f k,- e(v-2 4- C. ABSORPTION FIELD DATA Date installed 6o Soil rating (g.p.d./ft2 or ft2/bdrm) Or J� System type -'-r v 'f rr o ti Length `�3 ft. Width 2, O ft. Gravel below pipe G. o ft. Total depth !m. to ft. Eff. absorption area &% ft2 Monitoring tube Depression over field 1`l Date of adequacy test l2 r Results (Pass/Fail) �s S For ? bedrooms Fluid depth in absorption field before test 21'in. Elapsed Time: l414omin. Final fluid depth 2-Zin Water added 21oo gal. New depth in. Absorption rate >= (000 1- g.p.d. Any rejuvenation treatment (past 12 mo.) (Y/N & type) r4 a tAIf yes, give date D. LIFT STATION Date installed Size in gallons "Pump on" level at in. "Pum in. High water alarm level at in. D Cycles tested Meets alarm & circuit requirements? E. SEPARATION DISTANCES SEPARATION DISTANCES FROM WELL ON LOT TO: Septic tank/lift station on lot � t 000 r On adjacent lots / o o � �- Absorption field on lot ? 1&0, f Public sewer main _ rti4 /40►, e --- Sewer Sewer /septic service line To" Anirnal containment areas /V D f On adjacent lots / oo 14 - Public sewer manhole/cleanout. Holding tank t4 ! A, Manure/animal excrete storage areas !vd r� SEPARATION DISTANCES FROM SEPTIC/HSG TANK ON LOT TO: Building foundation 3 J r Water main N . Wells on adjacent lots i v,0 ' -f- Property line 3S " Absorption field —'�: " ," O Water service line ? so Surface water SEPARATION DISTANCE FROM ABSORPTION FIELD ON LOT TO: "da ,,�- Property line /�` Building foundation �o �f Water main /`J A Water Service line 10 o 14- Surface water iOa ��- Driveway, parking/vehicle storage 2 0 Curtain drain o � C,, Wells on adjacent lots P o / F. COMMENTS Gvctf r rr T kA r IL &A If G. ENGINEER'S CERTIFICATION v d : y� p I certify that I have determined through field inspections and �' r°=- •;1 �l review of Municipal records that the above systems are in �• 9 T °� •fes • • • •fid conformance with MOA COSA guidelines in effect on this date. / A Engineer's Printed Name M� rlti C� rrhu� ®O '� MICHA L� 'NDERSON , -94 Date'6 !. ��'.•�`eo COSA Fee $ `'� i Waiver Fee $ Date of Payment i h q /f f Date of Payment Receipt Number �-� �� Receipt Number. (Rev. 11/05) Aarow Pump & Well Service LLC (907)346-9355 Inspection Report Lot 4, Block 1 McMahon Camera well to 45'. No leaks found in casing. Install new well seal and conduit. Casing has no perforations above 45'. Brian R. Wille Aarow Pump & Well Service SGS Ref.# 1107391001 Client Name Mike N. Anderson, P.E. Project Name/# Jim MacFee Client Sample ID Jim MacFee Matrix Drinking Water PWSID 0 Sample Remarks: Parameter Metals by ICP/MS Arsenic Waters Department Total Nitrate/Nitrite-N Microbiology Laboratory E. Coli Total Coliform Results LOQ ND 5.00 0.530 0.100 Negative 1 Negative 1 Printed Date/Time 01/11/2011 8:08 Collected Date/Time 12/29/2010 14:30 Received Date/Time 12/29/2010 15:07 Technical Director Stephen C. Ede Allowable Prep Analysis Units Method Container ID Limits Date Date Init ug/L EP200.8 C (<10) 01/05/11 01/07/11 NRB mg/L SM20 4500NO3-F B (<10) IOOmL SM20 9223B A I OOmL SM20 9223B A 12/29/10 AYC 12/29/10 DLC 12/29/10 DLC HUFFMAN ROAD S 90°00'00" E 147.37' AC D/W AC 00 D/W N O N n N 10' UTILITY EASEMENT S90`00'00"E 147.53' ANCHORAGE RECORDING DISTRICT, ALASKA AS -BUILT OF: McMAHON SUBDIVISION LOT 4 BLK 1 PLAT 65-86 SHT 1 OF 2 SURVEY CERTIFICATE: I, John L. Schuller, Have conducted a physical survey of this property as shown on this drawing and that the improvements situated hereon are within the property lines and no enchroachments exist other than noted. Under no circumstance should any information on this drawing be used for construction of fences, structures, improvements, or for establishing boundary lines. EXCLUSION NOTES: It is the owners responsibility to determine the existence of any easements, covenants, or restrictions which do not appear on the recorded subdivision plat. WORK ORDER NUMBER: DATE: SCALE: E-MAIL: DEC 4, 2010 1 "=30' k=go k net 10-0/2 DRANK BY: CHECKED BY QMD NUMBER: BOCK AF; JLS 2835 100367 LOT 14 (147.50' R) SEPTIC VENTS (TYP) i • UM cm (147.50' R) O = FND 5/8" REBAR .T�OF.......... 01 49TH . tY... . ,.. ... :... r .JOHN L. SCHULLER: • O LS -10408 A2S� 1 7 %6 fessiono\ _'�� 0 Ln A O N N Lv CSL S6tl ADL IVDR��� � . o 1831 Talkeetna Street Anchorage, Alaska 99508 (907) 227-1455 office (907) 274-4992 fax F— 51.2' DECK • 64.0' O � N SHED W 16.2' m EXISTING —x—x—x w x C HOUSE �w N 0 51.4' 20.5' N O - 0 0 O 0 0 O O e' . Z O 11.7' Z LOT 4 BLK 1 10' UTILITY EASEMENT S90`00'00"E 147.53' ANCHORAGE RECORDING DISTRICT, ALASKA AS -BUILT OF: McMAHON SUBDIVISION LOT 4 BLK 1 PLAT 65-86 SHT 1 OF 2 SURVEY CERTIFICATE: I, John L. Schuller, Have conducted a physical survey of this property as shown on this drawing and that the improvements situated hereon are within the property lines and no enchroachments exist other than noted. Under no circumstance should any information on this drawing be used for construction of fences, structures, improvements, or for establishing boundary lines. EXCLUSION NOTES: It is the owners responsibility to determine the existence of any easements, covenants, or restrictions which do not appear on the recorded subdivision plat. WORK ORDER NUMBER: DATE: SCALE: E-MAIL: DEC 4, 2010 1 "=30' k=go k net 10-0/2 DRANK BY: CHECKED BY QMD NUMBER: BOCK AF; JLS 2835 100367 LOT 14 (147.50' R) SEPTIC VENTS (TYP) i • UM cm (147.50' R) O = FND 5/8" REBAR .T�OF.......... 01 49TH . tY... . ,.. ... :... r .JOHN L. SCHULLER: • O LS -10408 A2S� 1 7 %6 fessiono\ _'�� 0 Ln A O N N Lv CSL S6tl ADL IVDR��� � . o 1831 Talkeetna Street Anchorage, Alaska 99508 (907) 227-1455 office (907) 274-4992 fax