HomeMy WebLinkAboutHILLSIDE PARK PUD LT 16Hillside Pork
Lot 16
#015-312-25
Expired Permit
Municipality of Anchorage
George P. Wuerch, Mayor
Building Safety Division
P O Box 196650 · 4700 S Bragaw Street
Anchorage, Alaska 99519-6650 · (907) 343-8301
http//~x~v~ ci anchorage ak us
~epartmeat o~
Public Works
6/8/2001
Carl Cross
2230 Woodworth C~r
Anchorage AK 99517
SubJect
Dear Carl
On-S~te Water and/or Wastewater Permit
Permit Number SW000217
~ParcelID #015-312-25 _ ~
An On-S~te Water/Wastewater Perunt, number SW000217, ~ssued by tins office for a s~ngle-famfly
system, will expire on July 10, 2001 Tins permit was valid for 365 calendar days
If tins was a well permit and the well has been drilled, a well log must be sent to th~s office for
documentation of the installation and to close the penmt
If th~s permit was for a wastewater disposal system, an original as-built ~nspect~on report must be sent to
tins office for review, approval and documentatmn Tins as-built inspection report must be s~gned by
the hcensed Professmnal Engineer who ~nspected the ~nstallatlon of the system As-bmlt inspection
reports are reqmred to be subrmtted w~tinn 30 days of the complehon of the system
If no system was ~nstalled under this permit, and you are still planning to ~nstall a well or wastewater
dzsposal system, a new permit must be obtained from tins office A new penmt may be ~ssuedfree of
charge for a second year ~fthe apphcatmn for the renewal ~s received on or before the date of expiration
of the original permit
When appl3nng for a new permit, the fees are $320 O0 for a wastewater permit and $120 00 for a well
penmt
If you have any questions, please call this office at 343-7904
Jam~ Cross, PE
Marlager
On-S~te Water and Wastewater Program
eno Copy of permit
MUNICIPALITY OF ANCHORAGE
Department of Health and Human Services
On-Slte Services Program
825 L Street, Room 502
P 0 Box 196650, Anchorage, AK 99519-6650
(907) 343..4744
ON-SITE WASTEWATER DISPOSAL SYSTEM PERMIT
Renewal
Date Issued Jul 10, 2000
Exp~rahon Date Jul 10, 2001
Perm,t Number: SW000217
Legal Descnphon HILLSIDE PARK PUD LT 16
Design Engineer 0007 Tobben Spurkland, PE
Owner Name Carl Cross
Owner Address 2230 Woodworth C~r
Anchorage, AK 99517-
Parcel ID 015-312-25
S~te Address
Lot S~ze 36371 SQ FT
Total Bedrooms 4 Permit Bedrooms 4
Th~s permit ~s for the construchon of
[] D~sposal F~eld [] SepbcTank [] Holding Tank [] Privy
[] Pnvate Well [] Water Storage
All construcbon must be in accordance w~th
I The attached approved design
2 All requirements specified m Anchorage Mumc~pal Code Chapters 15 55 and 15 65 and the State of Alaska
Wastewater D~sposal Regulations ( 18AAC72 ) and Dnnk~ng Water Regulahons ( 18AAC80 )
3 The engineer must nobly DHHS at least 2 hours pnor to each mspechon Prowde nobflcat~on by calhng
(907) 343-4744 ( 24 hours) ( Not required for a Water Supply Permit only )
4 From October 15 to April 15, a subsurface so~l absorption system under construction dunng freezing weather
must be e~ther A Open and closed on the same day
B Covered, sealed, and heated to prevent freezing
R~ck Mystrorn
Mayor
Municipality of Anchorage
Department of Health and Human Services
825 "L" Street
P O Box 196650 Anchorage, Alaska 99519-6650
http//www Cl anchorage ak us
June 7, 2000
Carl Cross
2230 Woodworth Car
Anchorage, AK 99517
Subject
Hills Park PUD, Lot 16
Permat # SW990185 PID # 015-312-25
The subject permit #SW990185 ~ssued by flus office for a sxngle family well and/or on-
sate wastewater system, ~s due to expire 365 days after aris issuance on July 9, 1999
If tins as a well penmt and you have drilled the well, a well log must be sent to this office
for documentation of the installation and to close the penmt
If this as an on-s~te wastewater system and a licensed Professaonal Engineer has anspected
the anstallat~on, the onDnal as-bmlt inspection report must be sent to tlus office for
review, approval and documentation All anspectlon reports must be submitted w~ttun 30
days of constmctaon completion
A new permit must be obtmned from tins office for a well and/or on-sate wastewater
system NOT anstalled by the explrataon date However a new permit can be assuedfree of
charge for a second year afthe apphcat~on for the renewal is receaved on or before the
date of exparataon of the original permxt for which a fee was paid
When applying for a new penmt aRer the onganal permat has expired or for more than a
second year, the fees are $320 00 for an on-s~te wastewater permit and $120 00 for a well
permit
If you have any questions, please call th~s office at 343-4744
Sancerely,
Program Manager
On-s~te Servmes
enc Copy of Permat
MUNICIPALITY OF ANCHORAGE
Department of Health end Human Services
On-Site Serwces Program
825 L Street, Room 502
PO Box 196650, Anchorage, AK 99519-8650
(907) 343-4744
ON-SITE WASTEWATER DISPOSAL SYSTEM PERMIT
Imhal
Date Issued Jul 09, 1999
Exp~rahon Date Jul 08, 2000
Permit Number: SW990185
Legal Descnphon HILLSIDE PARK PUD LT 16
Design Engineer 0007 Tobben Spurkland, PE
Owner Name Cad Cross
Owner Address 100 East 51st Street
Anchorage, AK 99503-
Parcel ID 015-312-25
S~te Address
Lot S~ze 36371 SQ FT.
Total Bedrooms 4 Permit Bedrooms 4
Th~s permit ~s for the construction of
[] Disposal F~eld [] SeptlcTank [] Holding Tank [] Privy
[] Private Well [] Water Storage
All construction must be in accordance w~th
I The attached approved design
2 All requirements specified ~n Anchorage Mumc~pal Code Chapters 15 55 and 15 65 and the State of Alaska
Wastewater D~sposal Regulabons ( 18AAC72 ) and Dnnkmg Water Regulations ( 18AAC80 )
3 The engineer must nohfy DHHS at least 2 hours prior to each ~nspecbon Prowde notification by calhng
(907) 343-4744 ( 24 hours ) ( Not reqmred for a Water Supply Permit only )
4 From October 15 to April 15, a subsurface so~l absorphon system under construction dunng froezmg weather
must be either A Open and closed on the same day
B Covered, sealed, and heated to prevent froezmg
Date ~'' ~'~
Date 7- ~- ~
203 W 15th Avenue, State 203
ANCHORAGE, ALASKA 99501
(907) 279-3916
Fax (907)-276-6013
SEPTIC SYSTEM DESIGN
LOT 16 HILLSIDE PARK
CARL CROSS
Mumc~pahtyofAnchorage
DepartmentofHealthand SocmlServmes
820I S~eet
Anchorage, Alaska99501
June 28, 1999
We are submitting an appllcat~on for the installation of a septic system for this lot The submtttal
consists of three (3) dravangs shovang the present improvements on the lot and the adjoining
propemes, (sheet 1/3), the proposed improvements of the lot, of wluch only the septic system ~s
subject to ttus penmt apphcatlon, (sheet 2/3), and a schemauc of the septtc system, (sheet 3/3) Soft
logs and percolation tests of apphcable testholes are also enclosed The septic system design is
based on the following
No Ground Water or Impervious Layer to 15 ft
Use Standard Trench
Stol Rating From Testhole
<1 mm/m = I 2 gal per sq fffday
No of Bedrooms 4
Reqmred Area per Bedroom 150/1 2 = 125 sq R
Total area reqmred 125 x 4 = 500 sqf~
Testhote depth 15 feet
Bottom Rock At 9 feet
Top Rock At 4 feet
Rock Depth 5 feet
Total Trench Length 500 / 10 = 50 t~
SYSTEM CONFIGURATION
STANDARD TRENCH
TOTAL LENGTH 50 FT
TOTAL WIDTH 2 FT
TOTAL DEPTH 9 FT
ROCK DEPTH 5 FT
COVER 5 FT
SEPTIC TANK 1250 GAL
The installation ofthts septic system wall not prevent wells from betng ~nstalled on the adjacent lots
There are no developed or natural surface / sub surface drmnage courses on th~s or the adjacent lots
The proposed septm system will not change the general slope of the area Pondmg and/or concentratton of surface
mnoffwdl not result from thts mstallatton
/ -~, PHUKAN CONSULTING ENGINEERS & ASSOCIATES, INC.
C,wl * Geotechmcal Engineering * Matenals Testmg * Env]romental
?ANWT - 3640 US STANDARD SIEVE O?EI'IINO IN UVCHES US STANDARDS1EVENUMBER$ liYDROMETER
I 3/8' 6320 2680 192 808 ~ ____. -- ~----'-' 40
#,o ,o,,o 727o s2, 479 ~ =
#100 17460 13820 991 09 i 60 ~
/-~, PHUKAN CONSULTING ENGINEERS & ASSOCIATES, INC.
C,wl * Geotechmcal Engineering * Matenals Testmg * Env]romental
- 3~0 us SPA~SmV~oPE~m~on~=cms us s~sm~s
6320 2680 192 808 ~ ~ ~ 40
LDT 30 /
/
LDT 28
LOT 29
50 0 L~IOO 15o
//
,.->- ,.,
:hoLe
LDT 17
DT 19
LDT 18
LZ 20
TOBBEN SPURKLAND P
203 W 15TH AVENUE
ANCH AK. 99501
(907'~ 279-3916
LOT 16 HILLSIDE PARK
CARL CROSS
720! CROOKED TREE DRIVE
SEPTIC SYSTEM DESIGN
DATE APR/L 14, I,~99
SHEET I/3 GRID 2559
PERMIT // SW9900XX PARCEL ID YY HSPO0161 DWG
~ 49~h
\ \
50 75 'mO WS ~50
SCALE I' = 50 FT "
SPURKLAND P E
205 W 15TH AVENUE
ANCH AK 99501
279 -5916
LOT 16 HILLSIDE PARK
7201 CROOKED TREE DRIVE
PARCEL ID YY
STANDARD TRENCH
SO FT LONG
9 £T DEEP
5 FT EFFECTIVE ROCK DEPTH
'i250 GAL SEPTIC TANK
I
I
SYSTEId DESIGN
JUNE 28. 1999
2/5 GRID 25J9
HSPO0162 DWG
PERWIT ~ SW9900XX
0-0 0 O__ 0
0 '~ I250 9al Sept,¢ f:ank
PRIWANY TRENCH
~ Stondord Trench
2'
SO' Lon9
9' ~eep
4' Cover
REP~CEWENT ~RENCH ~ ~ ~ ~ ~
ND SCALE
Monttom C(eonouts ~
5~ Cover
50 Ft O< Sep~,c ~ock
~0 9o( sept,c tonk
Effeohve
NO SCALE
TB3$EN SPURKLAND P E HILLSIDE PARA' LOT 16 sE~,~c SYSTEM SCHEMATIC
203 W15th Ave 720~ CROOKED FREE DATE JUNE 28, ~999
Anchomoge Ak 99501
~7~_~ CJNL ONOSS SHEET
PENWIT ~ S~9900XX PARCEL ID ~ XX HSPO0165 DWG
PERFORMED FOR
LEGAL DESCRIPTION
1
2
3
4-
5-
6
7
9
10
11
13-
14
15
16
17
18
19-
20-
Mumcipahty of Anchorage
DEPARTMENT OF HEALTH & HUMAN SERVICES
825 "L" Street, Anchorage, Alaska 99502-0650
SOILS LOG -- PERCOLATION TEST
/ f (ENGINEERS SEAL)
DATE PERFORMED /" / z,~ ¥
Township, Range, Sect,on '-[' [ ~.-~.'~ ~'~ '~
SLOPE SITE PLAN
WAS GROUND WATER
ENCOUNTERED~
IF YES, AT WHAT
DEPTH? pO
E
Depth to Water Alter
Momlermg? Date
Gross Net Depth to Net
Reading Date T~me T~me Water Drop
PERCOLATION RATE ~, J Im,nute$/mch) PERC HOLE DIAMETER
TEST RUN BETWEEN -- FTAND FT
COMMENTS
PERFORMED BY
ACCORDANCE WiTH ALL STATE AND MUNICIPAL GUIDELINES IN EFFECT ON THIS DATE
CERTIFY THAT THIS TEST WAS PERFORMED
OATE
72 008 (Rev 4185)
PERFORMED FOR
TH
Munl:il:allty of Anchorage
DEPARTMENT Or -~EALTH & HUMAN SERVICES
825 "L" Street, Ant borage, Alaska 99502-0650
SOILS LOG- PERCOLATION TEST
{ENG~I.NEER S SEAL)
DATE PERPO.MED' hTlq
LEGAl DESCRIPTION
1
2
3
4
5
6
7
8
9
lO
11
12
13
14
15
16
17-
18-
19-
20
~,OTTo t~ 0 F
DISCLAIMrR
Past and
Township Range Secbon
SLOPE SITE PLAN
WAS GROUND WATER
ENCOUNTERED~
$
IF YES ATWHAT ~)
D~T TH) . P
E
PERCOLATIONRATE 7~.f (m,nute$/,nchJPERCHOLED[AMETER __
TLST RUN BETWEEN __ FTAND FT
~rnnndwater rond~tlons lndlcatPd are qnr the dates
future presence °nd/or depth of groundwater can not be
shown only.
predicted
trom these oDse~.~,v.~lons
PERFORMED BY --
ACCORDANCE WITH ALL STATE AND MUNICIPAL GDI~ ~-LINES IN EFFECT ON THIS DATr
CERTIFY THAT TH S TEST WAS PERFORMEO IN
72-008 {Rev 4/85)
Of
Anchorage
P.O. BOX 196650
ANCHORAGE, ALASKA 99519-6650
(907) 343-4200
~X~X Tom Fink,
MA YOR
DEPARTMENT OF HEALTH & HUMAN SERVICES
January 8, 1988
Phillip Priebe
6333 Colgate
Anchorage, Alaska
99504
Subject: 'Lot 16 Hillside Park PUD Subdivision
Permit #870055, On-site Sewer Permit
01 - 3/2 2.5-
A permit issued by this Department for an individual well
and/or on-site sewer system has expired as of December 31,
1987.
Permits are issued on a calendar year basis by authority of
Municipal Ordinance.' A new permit must be obtained from this
Department for any well and/or on-site sewer system not
installed by the expiration date.
If you have drilled the well, a well log needS to be sent to
this Department for documentation of the installation and to
close the permit.
If a private engineer inspected the installation of the on-site
sewer system, the original as-built inspection report (three-part
form) must be sent to this office for review and approval, and
for documentation.
Effective January 1, 1988, a new fee schedule is in effect.
When re-applying for a new permit, the new fees are; $90.00 for
an on-site sewer permit; $50.00 for a well permit; $140.00 for
a combined sewer and well permit.
If there are any further questions, please call this office at
343-4744.
Sincerely,
Program Manager
On-site Services
RWR/ljw
enc: Copy of Permit
Eii)~:?.5 L SI"REET ~, AN,'::;HC)F~AGE, AK 9950
2 ~:~ 4- 4 '72 ()
APF'L ]i CANT'
A Ii) Il)R
1,,, Eli G A L ,
LOT S I ZE:
MAX
870055
04 / 2, 0 / 87
995()4
LOT: 16
BL..O[',K: NA
i_.isi:.ed !::~etcx,:: are i:.he) cq:::,t.:i.,:::Jr'r..':: avai:l, able 't,c, you :i.n designirtg your sept::.c
:::]/:::'{:.(::::ii,, ::::::::::::::::::::::: th~:::, c:,t::,t:i.c)r't 'l:.hat be::,s'l:., f':J.i'..s yc)L.,'.r'
4 0
47 ()
37 0
150
I ,.'::: e r' t ;i. i y t. h a t:
I,, :t: am i'amil:i, ar :,,~:it.l": t. he r'ei::luirement, s !'(::.u" cir'u.--.s;i.'t.~:.> servers and :.,,;el:l.s as set
'l'c;q"'Lh J::iy tl"t(::, Ivluriic:ipa].:J. ty I:)f' Ar'lchc)r'a(}j(.:~ (MOA) ,::ir'id th(::.) State (:::,~' A:l. ask~;~:.
~::':~.,, :[ ix.~:i.'J.]. :i.i-::ylL/:'::].:{. thE,
and in cc~ml;:,:i.;i, anc<:.::, ,,~:i.'t.h the des:i, gn c:r';i.t::H"ia cif' i:.l':is p(::.~r'm:i.t:.,,
:5,, I ~:i.:l.: aclher'e tc: a:i.:l. MOA ar'icl ~:i.~.<:.::.l:..t:.:, oJ' Alaska requiremertts i'c:)r 'Lhe se't. back
d :i. st antes i' r. om any ex :i. st :: ng ~.¢<:.:,I :I., wast ewat er' d :i. sposa ]. system or pub I :i. c
%(.Di.~ii:.:'P :L:~(::}(.:.~ :;ystE:'iii C)FI
4 ,, :1: Lir'i (::J G~ p :::i t a r'i (::J t h <':: '{:. !:: h J. s p ::.;: r' M J. 'L :L ::: V a ]. :i. d 'I:' (;:) r' a M a ::< :J. M:..~ (:;~ f' ',:.:.;~ b e d r' {:::,{:::, J'ii:B ;:::l"l d
:I: F: A I.. ]: !:::"T STA'I' I (:)1',! I S :I: I~,ISTAI....I....I::D
THEN (:1.) AN iELI::CTR:I:CP&., F::fl:I:RM:[T AND :I:NSP!::CTION ML!ST BIE OB'!"A:!:NE:D~I (2) AS"-'BU:I:LT'S
W ]: LL. NOT BI~ Ai::'F"FI!:iVED W Z "I"H[)IJ'T AN EI..E:CTR I CAI.. :i: NSF:'I:CT ]: ON RIE:I:::'CiI::i',T; AND (3) 'THIE
. ... ~f-..........
T F ~:: I:::':[~ BY~.~. ~ ~_ ~ ~
.......................
.......... .......... L ........ .......................................................................
MuniCipality of Anchorage
DEPARTMENT OF HEALTH & HI, MAN SERVICES
825 "L" Street, Anchorage, Alaska 99502-0650
SOILS LOG -- PERCOLATION TEST
(ENGINEEfl'~
PERFORMED FOR:
LEGAL DESCRIPTION:
1
2
3
4
5
6
7-
8
9
10
11
12
13
14
15
16
18
19
20
OC O~-T,~n~c 5o; J
DATE PERFORMED:
Township, Range, Section: ~r~ / c/' Y'[
SLOPE SITE PLAN
.~ROUND WATER
INTERED?
WalerAIter ia o~ 'fal~., p,4...~,
Date: ~ml anT,
Gross Net Depth to Net
Reading Date Time Time Water Drep
PERCOLATION RATE __
tminutes/incfl) Pi[RC HOLE DIAMETER
TEST RUN BETWEEN _ . FT AND FT
COMME.TS ._%,'/ -F,,,, 7. "~. ''~ / ?-' . ~, ~,,~ .. /,y ,.,,.f~,~ ~ I z_~ q
/.~ ~E~..~ ['tS"J'-~OZy. , ~. ~*~--' CERTIFY THAT THIS TEST WAS PERFORMED IN
PERFORMED BY:
ACCORDANCE WITH ALL STATE AND MUNICIPAL GUIDELINES IN EFFECT ON THIS DATE,/ DANTE: "~"~' /~'~
Iloo
19 oo
y
· 1489o55'1~"E.
,,. DRAINAGE ARROWS
......
-~ F~ .... ~e"~'~~ ~
SURVEYOR'S CERTIFI(~ATION.
HEREBY CERTIFY THAT I HAVE SURVEYED THE
~RoPERTY DESCRIBED ON THIS PLAT AND THE
ipflovEMEHTS SITUATED THEREON ARE LOCATED
AR SHOWN ON THIS PLAT.
OATEO THIS ./
NOTESs
BUILDING LOCATION SHOWN MEETD ALL SUBDiViSION OOV(MAMTS AND ZONING
ORDINANGES. · ~ / l
I. IT IG THE RESPONSIBILITY OF THE DUILDER TO'VERIFY ALL. ELEVATIONS WITH
RESPECT TO ALL UTILITIESi I~.
S. THIS P~AT REPNESENTS THE PARC~k OF pROPERTY DESCRIBED BELOW TAKEN
FROM THE RECORDED PLAT DESCRIBING THAT pARCiL, INSTN~MENT~ RECORDED
pRiOR TO OR AFTER THE FILING OF THE REOORDED PLAT ARE NOT SHOWN ON
THIS p~AT,
4, THE INFORMATION ON THIS FLAT Il FOR TH~ USE OF LEH~INO
SPECIFICALLY TO SHOW ANY CONFLICTS BETWEEN EXISTtNG STRUGTURE~ AND
pLATTED LOT LINEE OR EASEMENTS ) THE PLAT I~ NOT TO
POSITIONING ADDITIONAL ~TRUCTURE~ OA FENCES.
OTTS
2220 E. 88th. AVE.
ANCHORAGE ~ ALASKA 99507 349.645
~49 - 6452 - .