HomeMy WebLinkAboutHILLSIDE PARK PUD LT 16Hillside Pork Lot 16 #015-312-25 Expired Permit Municipality of Anchorage George P. Wuerch, Mayor Building Safety Division P O Box 196650 · 4700 S Bragaw Street Anchorage, Alaska 99519-6650 · (907) 343-8301 http//~x~v~ ci anchorage ak us ~epartmeat o~ Public Works 6/8/2001 Carl Cross 2230 Woodworth C~r Anchorage AK 99517 SubJect Dear Carl On-S~te Water and/or Wastewater Permit Permit Number SW000217 ~ParcelID #015-312-25 _ ~ An On-S~te Water/Wastewater Perunt, number SW000217, ~ssued by tins office for a s~ngle-famfly system, will expire on July 10, 2001 Tins permit was valid for 365 calendar days If tins was a well permit and the well has been drilled, a well log must be sent to th~s office for documentation of the installation and to close the penmt If th~s permit was for a wastewater disposal system, an original as-built ~nspect~on report must be sent to tins office for review, approval and documentatmn Tins as-built inspection report must be s~gned by the hcensed Professmnal Engineer who ~nspected the ~nstallatlon of the system As-bmlt inspection reports are reqmred to be subrmtted w~tinn 30 days of the complehon of the system If no system was ~nstalled under this permit, and you are still planning to ~nstall a well or wastewater dzsposal system, a new permit must be obtained from tins office A new penmt may be ~ssuedfree of charge for a second year ~fthe apphcatmn for the renewal ~s received on or before the date of expiration of the original permit When appl3nng for a new permit, the fees are $320 O0 for a wastewater permit and $120 00 for a well penmt If you have any questions, please call this office at 343-7904 Jam~ Cross, PE Marlager On-S~te Water and Wastewater Program eno Copy of permit MUNICIPALITY OF ANCHORAGE Department of Health and Human Services On-Slte Services Program 825 L Street, Room 502 P 0 Box 196650, Anchorage, AK 99519-6650 (907) 343..4744 ON-SITE WASTEWATER DISPOSAL SYSTEM PERMIT Renewal Date Issued Jul 10, 2000 Exp~rahon Date Jul 10, 2001 Perm,t Number: SW000217 Legal Descnphon HILLSIDE PARK PUD LT 16 Design Engineer 0007 Tobben Spurkland, PE Owner Name Carl Cross Owner Address 2230 Woodworth C~r Anchorage, AK 99517- Parcel ID 015-312-25 S~te Address Lot S~ze 36371 SQ FT Total Bedrooms 4 Permit Bedrooms 4 Th~s permit ~s for the construchon of [] D~sposal F~eld [] SepbcTank [] Holding Tank [] Privy [] Pnvate Well [] Water Storage All construcbon must be in accordance w~th I The attached approved design 2 All requirements specified m Anchorage Mumc~pal Code Chapters 15 55 and 15 65 and the State of Alaska Wastewater D~sposal Regulations ( 18AAC72 ) and Dnnk~ng Water Regulahons ( 18AAC80 ) 3 The engineer must nobly DHHS at least 2 hours pnor to each mspechon Prowde nobflcat~on by calhng (907) 343-4744 ( 24 hours) ( Not required for a Water Supply Permit only ) 4 From October 15 to April 15, a subsurface so~l absorption system under construction dunng freezing weather must be e~ther A Open and closed on the same day B Covered, sealed, and heated to prevent freezing R~ck Mystrorn Mayor Municipality of Anchorage Department of Health and Human Services 825 "L" Street P O Box 196650 Anchorage, Alaska 99519-6650 http//www Cl anchorage ak us June 7, 2000 Carl Cross 2230 Woodworth Car Anchorage, AK 99517 Subject Hills Park PUD, Lot 16 Permat # SW990185 PID # 015-312-25 The subject permit #SW990185 ~ssued by flus office for a sxngle family well and/or on- sate wastewater system, ~s due to expire 365 days after aris issuance on July 9, 1999 If tins as a well penmt and you have drilled the well, a well log must be sent to this office for documentation of the installation and to close the penmt If this as an on-s~te wastewater system and a licensed Professaonal Engineer has anspected the anstallat~on, the onDnal as-bmlt inspection report must be sent to tlus office for review, approval and documentation All anspectlon reports must be submitted w~ttun 30 days of constmctaon completion A new permit must be obtmned from tins office for a well and/or on-sate wastewater system NOT anstalled by the explrataon date However a new permit can be assuedfree of charge for a second year afthe apphcat~on for the renewal is receaved on or before the date of exparataon of the original permxt for which a fee was paid When applying for a new penmt aRer the onganal permat has expired or for more than a second year, the fees are $320 00 for an on-s~te wastewater permit and $120 00 for a well permit If you have any questions, please call th~s office at 343-4744 Sancerely, Program Manager On-s~te Servmes enc Copy of Permat MUNICIPALITY OF ANCHORAGE Department of Health end Human Services On-Site Serwces Program 825 L Street, Room 502 PO Box 196650, Anchorage, AK 99519-8650 (907) 343-4744 ON-SITE WASTEWATER DISPOSAL SYSTEM PERMIT Imhal Date Issued Jul 09, 1999 Exp~rahon Date Jul 08, 2000 Permit Number: SW990185 Legal Descnphon HILLSIDE PARK PUD LT 16 Design Engineer 0007 Tobben Spurkland, PE Owner Name Cad Cross Owner Address 100 East 51st Street Anchorage, AK 99503- Parcel ID 015-312-25 S~te Address Lot S~ze 36371 SQ FT. Total Bedrooms 4 Permit Bedrooms 4 Th~s permit ~s for the construction of [] Disposal F~eld [] SeptlcTank [] Holding Tank [] Privy [] Private Well [] Water Storage All construction must be in accordance w~th I The attached approved design 2 All requirements specified ~n Anchorage Mumc~pal Code Chapters 15 55 and 15 65 and the State of Alaska Wastewater D~sposal Regulabons ( 18AAC72 ) and Dnnkmg Water Regulations ( 18AAC80 ) 3 The engineer must nohfy DHHS at least 2 hours prior to each ~nspecbon Prowde notification by calhng (907) 343-4744 ( 24 hours ) ( Not reqmred for a Water Supply Permit only ) 4 From October 15 to April 15, a subsurface so~l absorphon system under construction dunng froezmg weather must be either A Open and closed on the same day B Covered, sealed, and heated to prevent froezmg Date ~'' ~'~ Date 7- ~- ~ 203 W 15th Avenue, State 203 ANCHORAGE, ALASKA 99501 (907) 279-3916 Fax (907)-276-6013 SEPTIC SYSTEM DESIGN LOT 16 HILLSIDE PARK CARL CROSS Mumc~pahtyofAnchorage DepartmentofHealthand SocmlServmes 820I S~eet Anchorage, Alaska99501 June 28, 1999 We are submitting an appllcat~on for the installation of a septic system for this lot The submtttal consists of three (3) dravangs shovang the present improvements on the lot and the adjoining propemes, (sheet 1/3), the proposed improvements of the lot, of wluch only the septic system ~s subject to ttus penmt apphcatlon, (sheet 2/3), and a schemauc of the septtc system, (sheet 3/3) Soft logs and percolation tests of apphcable testholes are also enclosed The septic system design is based on the following No Ground Water or Impervious Layer to 15 ft Use Standard Trench Stol Rating From Testhole <1 mm/m = I 2 gal per sq fffday No of Bedrooms 4 Reqmred Area per Bedroom 150/1 2 = 125 sq R Total area reqmred 125 x 4 = 500 sqf~ Testhote depth 15 feet Bottom Rock At 9 feet Top Rock At 4 feet Rock Depth 5 feet Total Trench Length 500 / 10 = 50 t~ SYSTEM CONFIGURATION STANDARD TRENCH TOTAL LENGTH 50 FT TOTAL WIDTH 2 FT TOTAL DEPTH 9 FT ROCK DEPTH 5 FT COVER 5 FT SEPTIC TANK 1250 GAL The installation ofthts septic system wall not prevent wells from betng ~nstalled on the adjacent lots There are no developed or natural surface / sub surface drmnage courses on th~s or the adjacent lots The proposed septm system will not change the general slope of the area Pondmg and/or concentratton of surface mnoffwdl not result from thts mstallatton / -~, PHUKAN CONSULTING ENGINEERS & ASSOCIATES, INC. C,wl * Geotechmcal Engineering * Matenals Testmg * Env]romental ?ANWT - 3640 US STANDARD SIEVE O?EI'IINO IN UVCHES US STANDARDS1EVENUMBER$ liYDROMETER I 3/8' 6320 2680 192 808 ~ ____. -- ~----'-' 40 #,o ,o,,o 727o s2, 479 ~ = #100 17460 13820 991 09 i 60 ~ /-~, PHUKAN CONSULTING ENGINEERS & ASSOCIATES, INC. C,wl * Geotechmcal Engineering * Matenals Testmg * Env]romental - 3~0 us SPA~SmV~oPE~m~on~=cms us s~sm~s 6320 2680 192 808 ~ ~ ~ 40 LDT 30 / / LDT 28 LOT 29 50 0 L~IOO 15o // ,.->- ,., :hoLe LDT 17 DT 19 LDT 18 LZ 20 TOBBEN SPURKLAND P 203 W 15TH AVENUE ANCH AK. 99501 (907'~ 279-3916 LOT 16 HILLSIDE PARK CARL CROSS 720! CROOKED TREE DRIVE SEPTIC SYSTEM DESIGN DATE APR/L 14, I,~99 SHEET I/3 GRID 2559 PERMIT // SW9900XX PARCEL ID YY HSPO0161 DWG ~ 49~h \ \ 50 75 'mO WS ~50 SCALE I' = 50 FT " SPURKLAND P E 205 W 15TH AVENUE ANCH AK 99501 279 -5916 LOT 16 HILLSIDE PARK 7201 CROOKED TREE DRIVE PARCEL ID YY STANDARD TRENCH SO FT LONG 9 £T DEEP 5 FT EFFECTIVE ROCK DEPTH 'i250 GAL SEPTIC TANK I I SYSTEId DESIGN JUNE 28. 1999 2/5 GRID 25J9 HSPO0162 DWG PERWIT ~ SW9900XX 0-0 0 O__ 0 0 '~ I250 9al Sept,¢ f:ank PRIWANY TRENCH ~ Stondord Trench 2' SO' Lon9 9' ~eep 4' Cover REP~CEWENT ~RENCH ~ ~ ~ ~ ~ ND SCALE Monttom C(eonouts ~ 5~ Cover 50 Ft O< Sep~,c ~ock ~0 9o( sept,c tonk Effeohve NO SCALE TB3$EN SPURKLAND P E HILLSIDE PARA' LOT 16 sE~,~c SYSTEM SCHEMATIC 203 W15th Ave 720~ CROOKED FREE DATE JUNE 28, ~999 Anchomoge Ak 99501 ~7~_~ CJNL ONOSS SHEET PENWIT ~ S~9900XX PARCEL ID ~ XX HSPO0165 DWG PERFORMED FOR LEGAL DESCRIPTION 1 2 3 4- 5- 6 7 9 10 11 13- 14 15 16 17 18 19- 20- Mumcipahty of Anchorage DEPARTMENT OF HEALTH & HUMAN SERVICES 825 "L" Street, Anchorage, Alaska 99502-0650 SOILS LOG -- PERCOLATION TEST / f (ENGINEERS SEAL) DATE PERFORMED /" / z,~ ¥ Township, Range, Sect,on '-[' [ ~.-~.'~ ~'~ '~ SLOPE SITE PLAN WAS GROUND WATER ENCOUNTERED~ IF YES, AT WHAT DEPTH? pO E Depth to Water Alter Momlermg? Date Gross Net Depth to Net Reading Date T~me T~me Water Drop PERCOLATION RATE ~, J Im,nute$/mch) PERC HOLE DIAMETER TEST RUN BETWEEN -- FTAND FT COMMENTS PERFORMED BY ACCORDANCE WiTH ALL STATE AND MUNICIPAL GUIDELINES IN EFFECT ON THIS DATE CERTIFY THAT THIS TEST WAS PERFORMED OATE 72 008 (Rev 4185) PERFORMED FOR TH Munl:il:allty of Anchorage DEPARTMENT Or -~EALTH & HUMAN SERVICES 825 "L" Street, Ant borage, Alaska 99502-0650 SOILS LOG- PERCOLATION TEST {ENG~I.NEER S SEAL) DATE PERPO.MED' hTlq LEGAl DESCRIPTION 1 2 3 4 5 6 7 8 9 lO 11 12 13 14 15 16 17- 18- 19- 20 ~,OTTo t~ 0 F DISCLAIMrR Past and Township Range Secbon SLOPE SITE PLAN WAS GROUND WATER ENCOUNTERED~ $ IF YES ATWHAT ~) D~T TH) . P E PERCOLATIONRATE 7~.f (m,nute$/,nchJPERCHOLED[AMETER __ TLST RUN BETWEEN __ FTAND FT ~rnnndwater rond~tlons lndlcatPd are qnr the dates future presence °nd/or depth of groundwater can not be shown only. predicted trom these oDse~.~,v.~lons PERFORMED BY -- ACCORDANCE WITH ALL STATE AND MUNICIPAL GDI~ ~-LINES IN EFFECT ON THIS DATr CERTIFY THAT TH S TEST WAS PERFORMEO IN 72-008 {Rev 4/85) Of Anchorage P.O. BOX 196650 ANCHORAGE, ALASKA 99519-6650 (907) 343-4200 ~X~X Tom Fink, MA YOR DEPARTMENT OF HEALTH & HUMAN SERVICES January 8, 1988 Phillip Priebe 6333 Colgate Anchorage, Alaska 99504 Subject: 'Lot 16 Hillside Park PUD Subdivision Permit #870055, On-site Sewer Permit 01 - 3/2 2.5- A permit issued by this Department for an individual well and/or on-site sewer system has expired as of December 31, 1987. Permits are issued on a calendar year basis by authority of Municipal Ordinance.' A new permit must be obtained from this Department for any well and/or on-site sewer system not installed by the expiration date. If you have drilled the well, a well log needS to be sent to this Department for documentation of the installation and to close the permit. If a private engineer inspected the installation of the on-site sewer system, the original as-built inspection report (three-part form) must be sent to this office for review and approval, and for documentation. Effective January 1, 1988, a new fee schedule is in effect. When re-applying for a new permit, the new fees are; $90.00 for an on-site sewer permit; $50.00 for a well permit; $140.00 for a combined sewer and well permit. If there are any further questions, please call this office at 343-4744. Sincerely, Program Manager On-site Services RWR/ljw enc: Copy of Permit Eii)~:?.5 L SI"REET ~, AN,'::;HC)F~AGE, AK 9950 2 ~:~ 4- 4 '72 () APF'L ]i CANT' A Ii) Il)R 1,,, Eli G A L , LOT S I ZE: MAX 870055 04 / 2, 0 / 87 995()4 LOT: 16 BL..O[',K: NA i_.isi:.ed !::~etcx,:: are i:.he) cq:::,t.:i.,:::Jr'r..':: avai:l, able 't,c, you :i.n designirtg your sept::.c :::]/:::'{:.(::::ii,, ::::::::::::::::::::::: th~:::, c:,t::,t:i.c)r't 'l:.hat be::,s'l:., f':J.i'..s yc)L.,'.r' 4 0 47 () 37 0 150 I ,.'::: e r' t ;i. i y t. h a t: I,, :t: am i'amil:i, ar :,,~:it.l": t. he r'ei::luirement, s !'(::.u" cir'u.--.s;i.'t.~:.> servers and :.,,;el:l.s as set 'l'c;q"'Lh J::iy tl"t(::, Ivluriic:ipa].:J. ty I:)f' Ar'lchc)r'a(}j(.:~ (MOA) ,::ir'id th(::.) State (:::,~' A:l. ask~;~:. ~::':~.,, :[ ix.~:i.'J.]. :i.i-::ylL/:'::].:{. thE, and in cc~ml;:,:i.;i, anc<:.::, ,,~:i.'t.h the des:i, gn c:r';i.t::H"ia cif' i:.l':is p(::.~r'm:i.t:.,, :5,, I ~:i.:l.: aclher'e tc: a:i.:l. MOA ar'icl ~:i.~.<:.::.l:..t:.:, oJ' Alaska requiremertts i'c:)r 'Lhe se't. back d :i. st antes i' r. om any ex :i. st :: ng ~.¢<:.:,I :I., wast ewat er' d :i. sposa ]. system or pub I :i. c %(.Di.~ii:.:'P :L:~(::}(.:.~ :;ystE:'iii C)FI 4 ,, :1: Lir'i (::J G~ p :::i t a r'i (::J t h <':: '{:. !:: h J. s p ::.;: r' M J. 'L :L ::: V a ]. :i. d 'I:' (;:) r' a M a ::< :J. M:..~ (:;~ f' ',:.:.;~ b e d r' {:::,{:::, J'ii:B ;:::l"l d :I: F: A I.. ]: !:::"T STA'I' I (:)1',! I S :I: I~,ISTAI....I....I::D THEN (:1.) AN iELI::CTR:I:CP&., F::fl:I:RM:[T AND :I:NSP!::CTION ML!ST BIE OB'!"A:!:NE:D~I (2) AS"-'BU:I:LT'S W ]: LL. NOT BI~ Ai::'F"FI!:iVED W Z "I"H[)IJ'T AN EI..E:CTR I CAI.. :i: NSF:'I:CT ]: ON RIE:I:::'CiI::i',T; AND (3) 'THIE . ... ~f-.......... T F ~:: I:::':[~ BY~.~. ~ ~_ ~ ~ ....................... .......... .......... L ........ ....................................................................... MuniCipality of Anchorage DEPARTMENT OF HEALTH & HI, MAN SERVICES 825 "L" Street, Anchorage, Alaska 99502-0650 SOILS LOG -- PERCOLATION TEST (ENGINEEfl'~ PERFORMED FOR: LEGAL DESCRIPTION: 1 2 3 4 5 6 7- 8 9 10 11 12 13 14 15 16 18 19 20 OC O~-T,~n~c 5o; J DATE PERFORMED: Township, Range, Section: ~r~ / c/' Y'[ SLOPE SITE PLAN .~ROUND WATER INTERED? WalerAIter ia o~ 'fal~., p,4...~, Date: ~ml anT, Gross Net Depth to Net Reading Date Time Time Water Drep PERCOLATION RATE __ tminutes/incfl) Pi[RC HOLE DIAMETER TEST RUN BETWEEN _ . FT AND FT COMME.TS ._%,'/ -F,,,, 7. "~. ''~ / ?-' . ~, ~,,~ .. /,y ,.,,.f~,~ ~ I z_~ q /.~ ~E~..~ ['tS"J'-~OZy. , ~. ~*~--' CERTIFY THAT THIS TEST WAS PERFORMED IN PERFORMED BY: ACCORDANCE WITH ALL STATE AND MUNICIPAL GUIDELINES IN EFFECT ON THIS DATE,/ DANTE: "~"~' /~'~ Iloo 19 oo y · 1489o55'1~"E. ,,. DRAINAGE ARROWS ...... -~ F~ .... ~e"~'~~ ~ SURVEYOR'S CERTIFI(~ATION. HEREBY CERTIFY THAT I HAVE SURVEYED THE ~RoPERTY DESCRIBED ON THIS PLAT AND THE ipflovEMEHTS SITUATED THEREON ARE LOCATED AR SHOWN ON THIS PLAT. OATEO THIS ./ NOTESs BUILDING LOCATION SHOWN MEETD ALL SUBDiViSION OOV(MAMTS AND ZONING ORDINANGES. · ~ / l I. IT IG THE RESPONSIBILITY OF THE DUILDER TO'VERIFY ALL. ELEVATIONS WITH RESPECT TO ALL UTILITIESi I~. S. THIS P~AT REPNESENTS THE PARC~k OF pROPERTY DESCRIBED BELOW TAKEN FROM THE RECORDED PLAT DESCRIBING THAT pARCiL, INSTN~MENT~ RECORDED pRiOR TO OR AFTER THE FILING OF THE REOORDED PLAT ARE NOT SHOWN ON THIS p~AT, 4, THE INFORMATION ON THIS FLAT Il FOR TH~ USE OF LEH~INO SPECIFICALLY TO SHOW ANY CONFLICTS BETWEEN EXISTtNG STRUGTURE~ AND pLATTED LOT LINEE OR EASEMENTS ) THE PLAT I~ NOT TO POSITIONING ADDITIONAL ~TRUCTURE~ OA FENCES. OTTS 2220 E. 88th. AVE. ANCHORAGE ~ ALASKA 99507 349.645 ~49 - 6452 - .