ON-SITE WASTEWATER INSPECTION REPORT
Permit Number: SW000191 PID Number: 067-062-04
til,/ 43.1 2
Page 1 of 3
• (907) 343-7904
✓ New ❑ Upgrade
Name:
Dave Warner
ABSORPTION FIELD
Address
25542 Denaina Drive
❑ Deep Trench ✓
❑ Other
Shallow Trench ❑ Bed ❑ Mound
Phone
Number of Bedrooms
4
Soil Rating
1.2 GPD/SF
Total depth from original grade
9.0 Fl.
LEGAL DESCRIPTION
Depth to pipe invert from original grade
Gravel depth beneath pipe
Subdivision Block Lot
5.0 Ft.
4.0*Ft
Denaly 1 24
Fill added above original grade
Gravel length
Township Range Section
1.0* Ft.
50.0* Ft.
Gravel width
Beds: Number of Lines
Distance between lines
SEPARATION DISTANCES
5.0*Ft.
N/A
N/A Ft.
To
From
Septic
Tank
AbsorptionHolding
Field
Lift Station
Tank
Sewer
Line
Total absorption area
500* Ft'
Number of trenches
1
Dist. between trenches
N/A Ft.
Well
127
147
N/A
N/A
83
TANK o Septic • S.T.E.P. ■ Holding • Other
Manufacturer
Capacity
Surface Water
100+
100+
N/A
N/A
Unknown
1250GaI.
Material
Number of compartments
Lot Line
65
36
N/A
N/A
NA
Unknown
2*
Foundation
42
65
N/A
N/A
LIFT STATION
Manufacturer
Capacity
Curtain Drain
N/A
N/A
N/A
N/A
Gal.
Remarks System installation was inspected by S&S
Pump on level at
Pump off level at
High water alarm at
Engineering. Engineer of record is no longer available.
in.
in.
in.
Field observations were taken on features visible from
Pump make and model
Electrical Inspections performed by
the surface during adequacy test.
Installer
PIPE MATERIAL House to lank Tank to *
* drainfield
Unknown
Drainfield * CO/MT *
Inspector S&S Engineering / Pannone Engineering*
BENCH MARK (Assumed elevation) ft
Inspection,
dates: 1' Unknown 2nd 9/18/13*
Location and description
p
3rd 41h
COMMUNITY DEVELOPMENT DEPARTMENT APPROVAL
Conditional Approval: Date
Engineers Stamp
✓' A• Cdr .i
*•TF# /\ iF�/
-,46.N
�/[/ / jP/t�
/�
Approved � Date /0-3 43
f Ven J%. 4nnoiZe'yl
oiZpCE a8149
�iik' POFE5 0 \- `
%its..-
'
nspection Report_1-1=1
I,t
N OTE:
SYSTEM INFORMATION VISIBLE FROM THE SURFACE WAS ACQUIRED THROUGH FIELD OBSERVATIONS DURING ADEQUACY
TEST. TOTAL DEPTH OF MONITORING TUBE FROM SURFACE AND DEPTH TO CLEAN OUT INVERT FROM SURFACE WERE
MEASURED. DUE TO THE UNAVAILABILITY OF THE ENGINEER OF RECORD IT IS ASSUMED THAT THE SYSTEM WAS
INSTALLED PER CODE AT THE TIME OF CONSTRUCTION.
1
SOT&
<441/6
SEPTIC AREA (E)
/� 1 �\
2 /N, M —_MIS
IF
1 7
��
WELL (E)
DRIVEWAY
GARAGE
4 BR
HOUSE (E)
O4;.FlOp
SFA FO
.35.9
m1
DRAIN FIELD (E)
*SOLE x 5'W x 4.0'ED x 9.0'TD*
•
—w
LOT 24
1250g SEPTIC TANK (E)
W/ DCO
DC1 N�
DC2
NOTES:
SEPTIC AREA (E)
RECORD DRAWING
PANNONE ENG SVC, LLC
P.O. BOX 100217 ANCHORAGE, AK 99510
PHONE (907) 272-8218 FAX (907) 272-8211
PLAN
DENALY, BLOCK 1, LOT 24
DAVE WARNER
25542 DENAINA DRIVE
EAGLE RIVER, AK 99577
'*:m /\ *?
% star
11\7 A
Steven R. I'annore•
6 8149 . '
RW, °got-Ess01*
Date
0/30/2013
Scale
P.I.D. NO
067-062-04
PERMIT NO.
SW000191
Sheet
2 OF 3
A
B
Ti
44,4
37.5
T2
51.7
44.4
DC1
57.8
50.2
DC2
61.9
54.2
01
79.2
51.7
M1
80.8
54.3 .
C2
68.5
79.0
M2
66.7
77.1
NOTES:
SEPTIC AREA (E)
RECORD DRAWING
PANNONE ENG SVC, LLC
P.O. BOX 100217 ANCHORAGE, AK 99510
PHONE (907) 272-8218 FAX (907) 272-8211
PLAN
DENALY, BLOCK 1, LOT 24
DAVE WARNER
25542 DENAINA DRIVE
EAGLE RIVER, AK 99577
'*:m /\ *?
% star
11\7 A
Steven R. I'annore•
6 8149 . '
RW, °got-Ess01*
Date
0/30/2013
Scale
P.I.D. NO
067-062-04
PERMIT NO.
SW000191
Sheet
2 OF 3
NOTE:
SECTION AND PROFILE INFORMATION VISIBLE FROM THE SURFACE WAS ACQUIRED THROUGH FIELD OBSERVATIONS
DURING ADEQUACY TEST. TOTAL DEPTH OF MONITORING TUBE FROM SURFACE AND DEPTH TO CLEAN OUT INVERT FROM
SURFACE WERE MEASURED. DUE TO THE UNAVAILABILITY OF THE ENGINEER OF RECORD IT IS ASSUMED THAT THE
SYSTEM WAS INSTALLED PER CODE AT THE TIME OF CONSTRUCTION.
4" 0 DRAIN PIPE
0
0
0
0U
3.0
14.0
=
wo
J Z
0
0 0
O U
SECTION
w
CO
OW r4" 0 DRAIN PIPE
j 0 1
U E
2509 SEPTIC TANK
(P)
LEGEND
w w WATER LINE/
WELL RADIUS
ss NEW SEPTIC
PROFILE
DESIGN PARAMETERS
EXISTING SEPTIC SYSTEM
NO. BEDROOM: 4 (600 gpd)
TANK SIZE: 1250g
PERC RATE = 1-5 MPI
SOIL RATING: 1.2 GPD/SF
AREA RQD: 500 SF
SYS. TYPE: WIDE TRENCH 4.0' E.D.
RE: 0.50
MIN LENGTH: 50 LF
ABBREVIATIONS
CU COPPER
DIP
TH
FC
T#
C#
M#
R.I.
DCO
DV
FS
BFG
OG
FG
TS&V
DUCTILE IRON PIPE
TEST HOLE
FOUNDATION CLEAN OUT
TANK CLEAN OUT NO.
CLEAN OUT NO.
MONITOR TUBE NO.
RIGID INSULATION
DOUBLE CLEAN OUT
DIVERTER VALVE
FLOW SPLITTER
BELOW FINISH GRADE
ORIGINAL GRADE
FINISH GRADE
TOPSOIL Sc VEGETATE
NOTES:
RECORD DRAWING
PANNONE ENG SVC, LLC
P.O. BOX 100217 ANCHORAGE, AK 99510
PHONE (907) 272-8218 FAX (907) 272-8211
DESIGN DETAILS
DENALY, BLOCK 1, LOT 24
DAVE WARNER
25542 DENAINA DRIVE
EAGLE RIVER, AK 99577
�����\� Date
`� OF A��SlII1 0/30/2013
A 0).• o- �t/ Scole
i* 43 •*,
lit lit•® P.I.D. NO
067-062-04
Steven R. Pannone
CE 8149
+V4. FESSI rim
PERMIT NO.
SW000191
Shee
3 OF 3
C�ertifieb grilling s
by
DOC Co dba
SULLIVAN WATER WELLS
P O. BOX 670272, CHUGIAK, ALASKA 99567 • TELEPHONE 688.2759
OWNER OF LAND /)AUiil W� IJn
ADDRESS /7o3&£04(Y s-z-attibla
LEGAL DESCRIPTION 1910J r4 LY /3t /C 1
La -4
PERMIT NUMBER DO 19 % Date of Issue 7 -o -200a
TAX INDENTIFICATION NUMBER O it / - O%aZ - tiq
Is well located at approved pennd Ioc nate ?
Method of Dnlhn @��/
9
Depth of well 111
Casing Type STI: h_f Wall Thickness inches
Diameter 6H inches, depth % ! feet
Liner Type /1� t.S i'.
Casing Stickup Above Ground
tPteis Q No
r rotary Q cable tool
Fd.
Static Water Level (from ground level)
cit. ca nib
feet
feet
Pumping level feet after hrs pumping qpm
Recover Rate rat' qpm
Method of Testing 4112.
Well Intake Opening Type pen End Q Open Hole
Q Screened, Start feet Stopped feet
Perforations Start-
tYStopped " feet
Grout Type Dsa,ra-J I c 4V' o uu'�me /St '
Depth from a feet, to feet
Pump Intake Depth feet
Pump Size hp Brand Name
Well Disinfected Upon Completion? tYenQ No
Method of Disinfection Cq;0ietid= P//i'
BORE HOLE DATA
DEPTH
From To
O
Cin.Jc Si rccU,
EB Qs erns kJ
3S
,s. i i 54.44 ?6;44.1.6t
.37
so
nor
l to
17' -
17S
Si4"14 6R4JA_ { Cl�d7flc'
Comments
E?cacti.
Dnller's Name ,B..:.,c.(/ f«.�--�'
ATTENTION It is the responsibility of the property owner to submit a copy of the well log to the proper authonty Municipality
of Anchorage Department of Health & Human Services and/or Department of Environmental Conservation MatSu Borough
Department of Environmental Conservation
MUNICIPALITY OF ANCHORAGE
Department of Health and Human Services
On -Site Services Program
825 L Street, Room 502
P 0 Box 196650, Anchorage, AK 99519-6650
(907) 343-4744
5-7-oo
hi` - 3: o O sa,.-i
r/$/ 4p w,
ON-SITE WASTEWATER DISPOSAL SYSTEM I WATER SUPPLY PERMIT
Initial
Permit Number. SW000191
Legal Description DENALY BLK 1 LT 24 ,
Design Engineer 0003 S & S Engineering
Owner Name David Warner
Owner Address 17032 Easy St , #A-10
Eagle River , AK 99577 -
This permit is for the construction of
n Disposal Field ✓ Septic Tank n Holding Tank
Date Issued Jun 23, 2000
Expiration Date Jun 23, 2001
Parcel ID 067-062-04
Site Address
Lot Size 40252 SQ FT
Total Bedrooms 4 Permit Bedrooms 4
Privy
Q Private Well — Water Storage
All construction must be In accordance with
1 The attached approved design
2 All requirements specified in Anchorage Municipal Code Chapters 15 55 and 15 65 and the State of Alaska
Wastewater Disposal Regulations (18AAC72 ) and Drinking Water Regulations (18AAC80 )
3 The engineer must notify DHHS at least 2 hours prior to each inspection Provide notification by calling
(907) 343-4744 (24 hours) ( Not required for a Water Supply Permit only )
4 From October 15 to April 15, a subsurface soil absorption system under construction during freezing weather
must be either A Open and closed on the same day
B Covered, sealed, and heated to prevent freezing
Received By
Issued By )1zi7ty' t t4,7(—/
Date e/ ?-74
Date —23 —00
HEALTH AUTHORITY
APPROVALS
SEWER BWATER
MAIN EXTENSIONS
SEWER & WATER
INSPECTION
ENGINEERING STUDIES
AND REPORTS
WELL INSPECTION
& FLOW TEST
SITE PLANS
ROAD DESIGN
SOIL TEST
PERCOLATION
TEST
STRUCTURAL S.
MECHANICAL
INSPECTIONS
ONSITE
WASTEWATER
DISPOSAL SYSTEM
DESIGN
ROBERT C COWAN, P E
June 8, 2000
MUNICIPALITY OF ANCHORAGE
Department of Health and Human Services
P.O Box 196650
Anchorage, AK 99519
REFERENCE. Lot 24, Block 1, DenalYS/D
CML ENGINEERS
(907) 694-2979
FAX(907)694-1211
It is requested that you issue a permit to install a septic system & well to serve the
proposed four bedroom dwelling ori the referenced property.
Two tests holes were excavated and percolation tests were performed The approximate
location of the test holes are located on the attached site plan At the time of excavation on
4/23/99 water was not found After momtonng on 5/15/99 they were found to still be dry.
A third test hole is planned at the time of construction
We do not anticipate any adverse effects on neighbormg wells, septic systems, reserve
areas or drainage patterns by the mstallation of the proposed septic system The
construction of this system will not prevent any future development on any of the adjacent
properties
If you require additional information, please contact us
Sincerely,
2
Robert C Cowan, P E
RCC/jhm
Enclosure
+DECEIVED
JUN 14 2000
MUNICIPALITY OF ANCHORAGE
\ JPnNA4ENTALSERVICES DIV'SI^
17034 NORTH EAGLE RIVER LOOP 6 SUITE 204 • EAGLE RIVER, ALASKA 99577
= 60'
SCALE
SITE PLAN
DESIGN
/ap
zZ
Z
r0 a
Z
z
Z
\ g Z
® /yZ c
3 /
Z
z
�rnrn
�rnrntit
\
§
4 r
0
§
�
«
a
O
�!&
Z
Z
Z
Z
Z
Z
nom
a AD
W 331
0
/
0
Q
«
r
I
hFRPUnMEbtoh
M tihlcfpalily bi Anchorage
bEPAhtMENt OP t-IEALtHI & HUMAN StMVICES
b25 "L" Street, Anchorage, Alaska 99502-5050
soils Lbt — hthcoLATIoN TEST
C 0.t%aVl LVa/nQ✓„
Il I I1.J1l1 l Ili, J AI 1
.e•cc OF 4i,7S11
it
14
g Q�y e 4,
1-1// GATE PERFORMED S lel Lic. ..
LEGAL bESCRIPIION L01 Z41glxk! DelQr1cr s/Q r, g Seclioh llrC , `
Tbwnshl Flange, i SLOPE SITE PLAN �Z1?
�RkT r r,-
• '1
2-
b'Sarl`►C5 -
sg,,d (sr)
G.14444o CAAv'bc
w arY SILT
WAS GROUND WATER
ENCOUNTERED?
IP YES AT WIIAt
btrtli?
bept11 lo *alar Aller
Monitoring? hale
S
L
0
P
E
w
heading
bale
%/a I ha
Groat
Time
0
Ne
tote
–
b pill o
Water
��(=51 O�-
/•
Net
brop
F I///
3, 6-"
AfrFr,.1.
3.8 "
RLC,,.r-
S.S••
, o
, o r.,,,,
8 u
II
—
,o 0I IN
—
'l -S'
$ "
Z/, "
m I
a
3'7-
,o a+,.'
tr,
I'EhcbLAtloH hAlt a • $ (mmulee,l chl PERC DOLE DIAMETER 6
f sf hUN bEtwtth ' Pt ANb Pt
bbMMENT§
hEhrbhMEb by 5 & S ENGINEERING _ `I7 17 — GEM. IPY tiIAI 71115 7E51 WAS PERFORMED IN
17034 Eagle River Loop Road No. 204
Act'bhbANCE WItrjoi4l�iiFEiNIfiI AL GUIDELINES 114 EPPEcf oN?His bA?E bAtE
12 Wd Kiev '44351
`i,[C V D ENGINEERING
20441 PTARMIGAN BLVD.
EAGLE RIVER/ AK 99577-8736
SOILS PERCOLATION TEST
Performed for: F. Robert Bell & Associates
Project.
Depth
(Peet)
1-
2-
a-
4-
5-
6-
7-
8-
9-
10-
11-
12-
i3-
14-
15-
16-
17-
18-
19-
•,4.19,,
i * 49 lit Pi
e••• •
1••••• .e.«••••••• 3
R`:
�. • CE 7116 =i
Date Performed 4/23/99
20-
Lot 28 McIntyre
TEST HOLE 0 99-28
Org— soft, black/brown, moist
SM — soft, bm, slightly gravelly
sandy silt, moist
SP — Med dense, gray slightly
gravelly sand
moist
B.0 H.
HOLE PRESOAKED PRIOR
TO PERCOLATION TEST
SEE ATTACHED SITE PLAN
FOR HOLE LOCATION
Was Ground water encountered? NO
Depth to water after monitoring? DRY
What depth? N/A
Date? 5/15/99
Reading
Date
Gross
Time
Net
Time
Depth to
Water
Net
Drop
1
4/26/99
1 20
-
8"
-
2
1.25
5 min
DRY
8"+
3
1 4
126
-
8"
-
4'
131
5 min
DRY
8"+
5'
1.32
-
8"
-
6
137
5 min
DRY
8"+
7
e
138
-
8"
-
8
L43
5 min
DRY
8"+
+
Water
Added
Percolation Rate > 1 (min/in) Perc Hole Diameter 6„
Test Run Between 3 feet and ___4,__ feet
Kenneth M Duffus, certify that this lest was performed in accordance with all State and Municipal guidelines In
effect on this date
SOILS PERCOLATION TEST '1iepve
PAoFESS1� P4.
pY
performed for: F. Robert Bell & Associates ' Date Performed' 4/23/99
Lot 2713 McIntyre
Project
Depth
(Peet)
8-'
9-
10-
11-
12-
13-
14-
15-
16-
17-
TGSI HOLE #
Org — soft, brown, moist
SM- med dense, silty sand,moist
GP—med dense, gray, sandy
gravel, moist
ML — soft, brown silt, moist
GP — Med dense, gray slightly
silty, sandy gravel, moist
SP - Med dense, gray sbghtly
silty, gravelly sand, moist
B.O H
HOLE PRESOAKED PRIOR
18- TO PERCOLATION TEST
19-
20-
99-2711
SEE ATTACHED SITE PLAN
FOR HOLE LOCATION
Was Ground water encountered? NQ
Depth to water after monitoring? pRY
What depth? N/A
pate? 5//5/99
heading
Pate
Gross
Time
Net
Time
Pepth to
Water
Net
Drop
1
4/27/99
11.00-
8"
-
2
1105
5min
4/16"
712/16"
3
7
1106
-
8"
-
4
1111
5min
3/16"
713/16"
5
t
1112
-
8"
-
6
11.17
5min
3/16"
713/16"
7
t
11.18
-
8"
-
8
11:23
5 min
2/16"
7 14/16"
9
1124
-
8"
-
10
1129
5min
1/16"
715/16"
11
11.30
-
8"
-
12
11.35
5mm
1/16"
715/16"
*
Water
Added
Percolation Rate ...LL (mm/m0 Perc Hole Piameter_6"
Test Run Between 35 feet and 4 5 feet
I, Kenneth M Duffus, certify that this test was performed in accordance with all State and Municipal guidelines in
effect on flus date
ON-SITE WASTEWATER DISPOSAL SYSTEM
CONSTRUCTION PRACTICES
and
MATERIAL SPECIFICATIONS
REFERENCE: Lot 24, Block 1, DenalY S/D
June 8, 2000
GENERAL:
1 The scope of this project includes the installation of a 1250 gallon (minimum)
septic tank and three shallow trenches to serve the proposed four bedroom
residence located on the referenced property.
2 Construction shall be m accordance with the approved site plan and design
drawings, Municipal permt with any special provisions or conditions, and all
applicable State and Municipal Wastewater Disposal Regulations
3 The contractor shall be responsible for obtaining any necessary underground
utility locates
4 Unless specifically agreed otherwise, the property owner shall be responsible
for final grading areas subsequently depressed from soil settlmg
5 Contractors mstallmg wastewater disposal systems must be certified by the
Municipal Health Department for system installations Owners installing
their own systems must also receive pnor approval from the Municipal Health
Department
SEPTIC TANK INSTALLATION:
1 A septic tank is to be constructed by a certified septic tank manufacturer.
Construction shall include two 4" cleanouts for pumping access
2 The septic tank shall be sufficiently bedded to prevent settling or shifting of
the tank
Page 2
Lot 24, Block 1, Denali6/D
June 7, 2000
3 All standpipes on the septic tank shall extend a muumum of 12 mches above final grade
4 Septic tanks installed with less than 4 ft. of cover shall be insulated
5 A foundation cleanout shall be mstalled one to four feet from the building foundation In
the line between the tank and the leachfield there shall be two adjacent cleanouts (unless
an effluent pumping system exists within the septic tank) These cleanouts shall be
located on undisturbed soil not more than 10 ft from the tank The first cleanout, in tine,
shall be to clean toward the leachfield The second cleanout shall be to clean toward the
septic tank
6 Final grading over the septic tank shall be such that a positive slope exists away from the
septic tank.
ABSORPTION TRENCHIDRAINFIELD INSTALLATION:
1. Excavate the proposed trench to the dimensions shown on the design The bottom of the
excavation shall be within 2 inches of level If the sidewalls of the excavation become
smeared, they must be raked or scratched (ruffed -up) before gravel (sewer rock)
placement
2 Once the gravel is mstalled, the distribution pipe is to be mstalled level with the
perforations faced downward Gravel is then to be placed over the distribution pipe to
provide a muumum of 2 inches of cover over the pipe
3 A silt bamer must be installed between the final gravel layer and the native soil backfill
Ensure the silt barrier covers the entire gravel surface before placing backfill
4 Monitor tubes shall be of four (4) inch diameter, installed approximately in the locations
shown on the design, and extend a muumum of 12 mches above final grade. The portion
of the momtonng tube extendmg through the gravel shall be perforated from the bottom of
the trench to the invert of the distribution pipe This is equivalent to the effective depth of
the gravel as noted on the design
5 Backfill over the final gravel layer must not be less than twenty-four (24) inches
Insulation must be mstalled when the backfill depth is less than thirty-six (36) inches The
finish grade over the trench must be mounded to prevent the formation of a depression
after settling
•Page3
Lot 24, Block 1, Dana1VS/D
June 7, 2000
MINIMUM MATERIAL SPECIFICATIONS:
1. Any septic tank proposed for installation must be constructed by a Municipal approved
septic tank manufacturer.
2 The following pipe materials are approved for use in septic system installations in the
Municipality of Anchorage
TvneofPine Perforated Solid
Cast Iron Yes Yes
ASTM D3034 (PVC) Yes Yes
ASTM F810 (HDPE) Yes No
ASTM D2662 (ABS) Yes Yes
Use of a type of pipe other than fisted above must be approved by the inspecting engineer
3 Insulation shall be at least 2" thick extruded direct bunal polystyrene (Dow Chemical
Company Styrofoam HI or equal)
4 Septic tank mlets and outlets shall be fitted with watertight couplings (Caulder, Fernco, or
equal)
5 A permeable nontoxic silt bamer (Typar 3401, Mirafi 140N, or equal) must be installed
between the final leachfield gravel layer and the native soil backfill
6 All leachfield gravel (sewer rock) shall be 0 5"-2 5" screened gravel with less than 3%
passing the #200 sieve.
7. When sand is bemg used as a filter material, its gradation specifications must conform to
current M 0 A or D E C. requirements, which ever requirement applies
INSPECTIONS:
Typically there will be a minimum of three (3) inspections required during the installation of the
wastewater disposal system These inspections will occur as follows
•
{ r
Page 4
Lot 24, Block 1, DenalyS/D
Juni 7, 2000
1. The first mspection must be conducted after the excavation of ditches, pits,
trenches, or beds and before the mstallation of any gravel A septic tank may be
set m place, but may not be backfilled before this inspection
2. The second inspection must be conducted after the placement of the silt banner,
gravel, distribution lines, standpipes, cleanouts, and insulation, but before the
placement of any other backfill
3 The final inspection is to occur upon final grading of the property
Often there will be more than these 3 inspections required Especially with the installation of
multiple trenches, sand filters, pressurized distribution systems, etc Thus, the inspecting engineer
is to be contacted at least 24 hours prior to the start of construction If necessary, a pre -
construction meeting will take place on-site The mspectmg engineer will not coordmate, direct
or control m any way the contractors activities
The owner shall contract with the contractor to perform the work outlined m these specifications
and plans and m accordance with the attached M 0 A. permit There will be no contractual
arrangement existing between the contractor and S & S Engineering. S & S Engineenng shall be
the owner's representative and will inspect the work as stated above to document the contractors
activities Final acceptance of the contractors work rests with the owner and the M 0 A
S & S Engineering shall have no liability to the owner or to others for acts or omissions of the
contractor or any other persons performing work on this project or the failure of the contractor to
carry out the work m accordance with these construction documents S & S Engmeenng's
inspecting engineer will not be responsible for the construction means, methods, techniques,
sequence, procedures or the safety precautions incident to this project
CONTRACTOR / INSTALLER
IN ,
IL
Mu"NICIPALITY OF ANCHORAGE
Development Services Department `ti Phone: 907-343-7904
On -Site Water & Wastewater Section Fax: 907-343-7997
Certificate of On -Site Systems Approval
Parcel I.D. 067-062-04
1. GENERAL INFORMATION
Expiration Date: Jr ^ Z ('V
Complete legal description Denaly, Block 1, Lot 24
Location (site address) 25542 Denaina Drive Eagle River, AK
Current property owner(s) Jeanne Reilly
Mailing address
Real estate agent
Day phone 223-5784
4811 White Birch Lane, Eagle River, AK 99517
2. TYPE OF DWELLING:
0 Single Family (w/wo ADU)
❑ Duplex
❑ Multiple Dwellings (Single Family and/or Duplex)
3. NUMBER OF BEDROOMS:
Day phone
4. TYPE OF WATER SUPPLY:
TYPE OF WASTEWATER DISPOSAL:
Private Well
El
Private Septic
Water Storage
❑
Holding Tank
❑
Community Well
❑
Community
❑
Public Water System
❑
Public Sewer
❑
Waiver request for: Distance:
Received by: Date:
COSA to be released to the engineer, unless otherwise requested by the engineer.
COSA Fee $ -990
Date of Payment 2-12311q
Receipt Number 060 16 D
COSA # 65C Q 1331
Waiver Fee $
Date of Payment
Receipt Number
Waiver #
5. STATEMENT OF INSPECTION BY ENGINEER
As certified by my seal affixed hereto and as of the validation date shown below, I verify that my investigation, based
on procedures outlined in the Certificate of On -Site Systems Approval Guidelines for this application, shows that the
on-site water supply and/or wastewater disposal system is (are) safe, functional and adequate for the number of
bedrooms and type of structure indicated herein. I further verify that based on the information obtained from the
Municipality of Anchorage files and from my investigation and inspection, the on-site water supply and/or wastewater
disposal system is (are) in compliance with all applicable Municipal and State codes, ordinances, and regulations in
effect at the time of installation. I acknowledge that On -Site staff may visit the site to verify the information submitted.
Name of Firm Forge Engineering Phone 907-522-7773
Address 1399 W. 34th Ave Suite 101, Anchorage AK 99503
Engineer's Printed Name Michael E. Anderson, P.E. Date 7/22/19
6. DSD SIGNATURE
_4� System #1 Approved for 4 bedrooms
System #2 Approved for bedrooms
Disapproved
Conditional approval for bedrooms, with the following stipulations:
��cn PRd�'R O
IJJJJ)))))11111�1
By: Original Certificate Date:
The Municipality of Anchorage Development Services Division (DSD) issues Certificates of On -Site Systems Approval (COSA) based only upon the
representations given in paragraph 5 by an independent professional civil engineer registered in the State of Alaska. The Municipality of Anchorage is
not responsible for errors or omissions in the professional engineer's work.
7. ATTACHMENTS:
COSA Checklist X Nitrate Advisory
Septic System Advisory Arsenic Advisory
Well Flow Advisory Other
COSA Checklist blue sheet
Legal Description: Denaly, Block 1, Lot 24
If more than 1 septic system on lot: COSA Checklist #
A. WELL DATA
❑ Well log is filed with Onsite (or attached)
Date drilled $/$/2000
Total depth 171 ft
Cased to 171 ft
ON Sanitary seal is functioning correctly
❑ Wires are properly protected
Casing height (above ground) 30 in.
Date of flow test for COSA 7/15/19
Static water level at beginning of test n/a ft.
Comments Artesian well
B. TANK DATA
Age of tank(s) 19* years
Tank type/material Septic/Unknown*
Measured operating fluid level in septic tank 13
❑ Standpipes/foundation cleanout per record drawing
Date of pumping 6/12/19 - House mostly vacant since pumping.
D. ABSORPTION FIELD DATA 5' Wide Trench
Which system tested (date installed) 8/8/00*
❑ ALL standpipes present per record drawing
Total measured depth from grade 8.9/8.3 ft (max)
Measured depth to pipe invert from grade 4'9/4'3 ft (min)
❑ N/A — pressurized field
❑ Monitor tubes go to bottom of effective. If not, state
depth into effective
Parcel ID: 067-062-04
of Structure served by this system
Well production at time of test 1.95 gpm
Water storage tank volume 600 gallons
Well disinfected for coliform test? ❑ Yes ❑ N
❑ Coliform bacteria is Negative
Nitrate mg/L ❑ Nitrate less than MRL (ND)
Arsenic ug/L ❑ Arsenic less than MRL (ND)
Collected by Forge Engineering
Date of Sample 07/12/19
C. LIFT STATION
❑ Required maintenance completed
Age of lift station years
Lift station material
Comments:
Adequacy test date
7/15/19
Results 2✓ Pass
For 4
Fluid depth prior to test 0
Water added 621
gal
New depth 0 in
Elapsed time 0
min
bedrooms
in
❑ Code -required soil cover over field Final fluid depth 0 in
❑ System presoaked
Absorption rate +600 gpd
(Required if vacant for greater than 30 days prior to Any rejuvenation treatment (past 12 months) None
date of test)
Gallons introduced 2000 gallons If yes, enter date
Comments/Deficiencies:
COSA Checklist yellow sheet
E. SEPARATION DISTANCES
From Private Well on Lot to: (Please enter distances if less than required or if community well)
Septic Tank/Lift Station on Lot > 100'
P/1
Yes
Community Sewer Manhole/Cleanout > 100'
Q Yes
if No
ft
Q Yes
if No ft
Neighboring Tank > 100' P/� Yes
if No
ft
Private Sewer/Septic Line > 25' 0 Yes
if No ft
Absorption Field on Lot > 100' 2] Yes
if No
ft
Holding Tank > 100' [71 Yes
if No ft
Neighboring Absorption Fields > 100'
Yes if No ft
Water Main > 10'
Animal Containment > 50' Q Yes
if No ft
F/� Yes
if No
ft
0 Yes if No ft
Water Service Line > 10'
0
Yes
if No
Manure/Animal Excreta Storage > 100'
If septic tank is under driveway comment below
Community Sewer Main > 75' F71 Yes
if No
ft
R] Yes
if No ft
From Septic/Holding Tank on Lot to: (Please enter distances if less than required)
Building Foundations > 10'
P/1
Yes
if No
ft
Surface Water > 100'
®✓ Yes if No ft
Property Line > 5'
0
Yes
if No
ft
Wells on Adjacent Lots:
Q
Absorption Field > 5'
El
Yes
if No
ft
Private Wells > 100'✓71
Yes if No ft
Water Main > 10'
0
Yes
if No
ft
Community Wells > 200'
0 Yes if No ft
Water Service Line > 10'
0
Yes
if No
ft
If septic tank is under driveway comment below
From Absorption Field on Lot to: (Please enter distances if less than required)
Building Foundation > 10' EJ Yes if No ft If absorption field is under driveway comment below
Property Line > 10'
Q
Yes
if No
ft
Wells on Adjacent Lots:
Water Main > 10'✓[]
Yes
if No
ft
Private Wells > 100' ®✓ Yes if No ft
Water Service Line > 10'
Q
Yes
if No
ft
Community Wells > 200' F� Yes if No ft
Surface Water > 100'✓�
Yes
if No
ft
F. ENGINEER'S COMMENTS
*System information taken from MOA records.
G. ENGINEER'S CERTIFICATION
l certify that / have determined through field inspections and review
of Municipal records that the above systems are in conformance with
MOA COSA guidelines in effect on this date.
COSA Checklist yellow sheet
AW
.
49th_
tit tlICHAEt E. ANDERSON : ti
No. CE -4389 r'
°7/22/19
419'�
Municipality of Anchorage
On -Site Water and Wastewater Program
(907) 343-7904
Certificate of On -Site Systems Approval
Parcel I.D. 067-062-04
1. GENERAL INFORMATION
Complete legal description Denaly, Block 1, Lot 24
Expiration Date:
-3o—/
Location (site address) 25542 Denaina Dr. Eagle River, AK 99577
Current Property owner(s) Dave Warner Day phone
25542 Denaina Dr.
Mailing address
Real Estate Agent Day phone
2. TYPE OF DWELLING:
El Single Family (w/wo ADU)
❑ Duplex
❑ Multiple Dwellings (Single Family and/or Duplex)
3. NUMBER OF BEDROOMS:
4
4. TYPE OF WATER SUPPLY: TYPE OF WASTEWATER DISPOSAL:
Individual Well i] Individual 0
Individual Water Storage ❑ Holding Tank ❑
Community Class Well ❑ Community ❑
Public Water System ❑ Public Sewer E
WaiverNariance request for:
Distance:
Received by:
COSA to be released to the engine/unless otherwise requested by the engineer.
Date: f .15)0
COSA Fee $ ttq 0 __
Date of Payment (O ati13
Receipt Number °MI0 to
COSA # 05C4 i'51#
Waiver Fee $
Date of Payment
Receipt Number
Waiver #
5. STATEMENT OF INSPECTION BY ENGINEER
As certified by my seal affixed hereto and as of the validation date shown below, I verify that my investigation,
based on procedures outlined in the Certificate of On -Site Systems Approval Guidelines for this application,
shows that the on-site water supply and/or wastewater disposal system is (are) safe, functional and adequate
for the number of bedrooms and type of structure indicated herein. I further verify that based on the information
obtained from the Municipality of Anchorage files and from my investigation and inspection, the on-site water
supply and/or wastewater disposal system is(are) in compliance with all applicable Municipal and State codes,
ordinances, and regulations in effect at the time of installation.
Name of Firm Pannone Engineering Services LLC
Address P.O. Box 100217, Anchorage Ak. 99510
Engineer's Printed Name Steven R Pannone
6. DSD SIGNATURE
VSystem #1 Approved for
System #2 Approved for
Disapproved
Conditional approval for
bedrooms
bedrooms
Phone (907) 272-8218
Date 9119/13
a'4 r ar g41a
AQP••'' 1
Aicbt'4gTh it *'�l
.even IR. rNinnone .
e 4��, CE -8149 �/Awe
bedrooms, with the following stipulations:
�Q1/4
0,,0 ,
J2 ON-SITE
WATEK AND
o�sy WASTEWATn
4 PROGRAMER jNT SERA
By:
The.r'nifge Development Services Division (DSD) issues Certificates of On -Site Systems Approval (COSA) based only
upon the representations given in paragraph 5 by an independent professional civil engineer registered in the State of Alaska. The Municipality
of Anchorage is not responsible for errors or omissions in the professional engineer's work.
Original Certificate Date: / 0 - 3 O —/3
7. ATTACHMENTS:
COSA Checklist X Nitrate Advisory
Septic System Advisory Arsenic Advisory
Well Flow Advisory Other
COSA blue sheet ( -
If more than 1 septic system is on the lot:
COSA Checklist # 1 of 1
Structure served by this system 1
Certificate of On -Site Systems Approval Checklist
Legal Description: Denaly, Block 1, Lot 24
A. WELL DATA
Well type Private If A, B, or C provide PWSID #
Date completed 8/8/2000 Sanitary seal (Y/N) Y
Total depth 171 ft. Cased to 171 ft.
FROM WELL LOG
Date of test 8/8/2000
Static water level Artesian
ft.
Well production 50+ g.p.m.
WATER SAMPLE RESULTS:
Coliform/aV! colonies/100 mL
Arsenic Ali> ug/L Date of sample: /0/g11-5
Nitrate /V P mg/L
B. SEPTIC/HOLDING TANK DATA
Tank Type/Material Septic/Steel
Tank size 1,250 gal.
Number of Compartments 2
Foundation cleanout (Y/N)
Date of pumping Q/ i y/26/ 3
C. ABSORPTION FIELD DATA
Date installed
Length 50 ft.
After 7/24/00
Depression over tank (Y/N) N
Pumper k 1S PLt M p 1
Parcel ID: 067-062-04
Well Log (Y/N) Y
Wires properly protected (WN) Y
Casing height (above ground) 24 in.
AT INSPECTION
9/18/13
Artesian*
3.2+
g.p.m.
ft.
Collected by: 17f:
Date installed After 7/24/00
Cleanouts (Y/N)
High water alarm (Y/N) N
Soil rating (g.p.d./112 or ft2/bdrm) 1.2 GPD/SF
Width 5
System type Shallow Trench
ft. Gravel below pipe 4 ft.
Total depth 101 ft. Eff. absorption area 500 ft2 Monitoring tube Y_
Date of adequacy test 9/18/13 D....,.I+. (Pass/Fail) Pass
Fluid depth in absorption field before test 0 in. Water added 614
Elapsed Time: 180 min. Final fluid depth 0 in.
Any rejuvenation treatment (past 12 mo.) (Y/N & type) No
Depression over field N
For 4 bedrooms
New depth 0 in.
600+
gal.
Absorption rate
If yes, give date
g.p.d.
D. LIFT STATION
Date installed Size in gallons
"Pump on" level at in. "Pump off' level at
Datum Cycles tested
E. SEPARATION DISTANCES
WELL ON LOT TO:
Septic tank/lift station on lot 100+
Absorption field on lot 100+
Public sewer main 75+
Sewer /septic service line 25+
Animal containment areas 100+
SEPTIC/HOLDING TANK ON LOT TO:
Property line 5+ Absorption field 5+
Water main 10+ Water service line 10+ Surface water 100+
Wells on adjacent lots 100+
ABSORPTION FIELD ON LOT TO:
Property line 10+ Building foundation 10+ Water main 10+
Water Service line 10+ Surface water 100+ Driveway, parking/vehicle storage 10+
Curtain drain 50+ Wells on adjacent lots 100+
Building foundation 5+
Manhole/Access (Y/N)
in. High water alarm level at
Meets alarm & circuit requirements?
in.
On adjacent lots 100+
On adjacent lots 100+
Public sewer manhole/cleanout 100+
Holding tank 100+
Manure/animal excrete storage areas 100+
F. COMMENTS
* Well Plug at 3 feet, assumed artesian
G. ENGINEER'S CERTIFICATION
I certify that I have determined through field inspections and
review of Municipal records that the above systems are in
conformance with MOA COSA guidelines in effect on this date.
Engineer's Printed Name Steven R. Pannone
Date 9/18/13
COSA brown sheet 10-10-12.doc
stsdift.cw• fter 4.9;9
agla".4,1'44,
ASBUILT
1 HEREBY CERTIFY THAT I HAVE SURVEYED THE
FOLLOWING DESCRIBED PROPERTY!
"7 -2't dens" tri"elad.."
AND THAT NO ENCROACHMENTS EXIST EXCEPT AS
INDICATED. IT IS THE RESPONSIBILITY OF THE
OWNER TO DETERMINE THE EXISTENCE OF ANY
EASEMENTS, COVENANTSt OR RESTRICTIONS
WHICH 00 NOT APPEAR ON THE SUBDI-
VIS1ON
_YkSIONP1417,,LUNPER'NO CIRCUMSTANCES S.
ANYiDA, ,TktIEREON":13EititEDkFlikGONSTEOCTI
, „
OF FENCE LINES, OR
FpFt5-:ErAELisiiista,ARY LINES.„
"")--
TATES LAND SURVEYING 694-0824
ailislip=1.1111.1..1111•1111111111111Millinry".•
Parcel I.D. 067-062-04
Municipality of Anchorage
On -Site Water and Wastewater Program
(907) 343-7904
Certificate of On -Site Systems Approval /F e- 'T s s
Expiration Date: - /
1. GENERAL INFORMATION
Complete legal description Denaly, Block 1, Lot 24
Location (site address) 25542 Denaina Dr. Eagle River, AK 99577
Current Property owner(s) Dave Warner Day phone
Mailing address 25542 Denaina Dr.
Real Estate Agent Day phone
2. TYPE OF DWELLING:
Single Family (w/wo ADU)
❑ Duplex
❑ Multiple Dwellings (Single Family and/or Duplex)
3. NUMBER OF BEDROOMS:
4
4. TYPE OF WATER SUPPLY: TYPE OF WASTEWATER DISPOSAL:
Individual Well 0 Individual 0
Individual Water Storage ❑ Holding Tank ❑
Community Class Well ❑ Community ❑
Public Water System ❑ Public Sewer ❑
WaiverNariance request for: Distance:
�-r
Received by.
COSA to be released to the engineer, unless otherwise requested by the engineer.
Date: i
COSA Fee $ Waiver Fee $
Date of Payment Date of Payment
Receipt Number 6 6 Receipt Number
COSA# ! 3 /5" Waiver#
5. STATEMENT OF INSPECTION BY ENGINEER
As certified by my seal affixed hereto and as of the validation date shown below, I verify that my investigation,
based on procedures outlined in the Certificate of On -Site Systems Approval Guidelines for this application,
shows that the on-site water supply and/or wastewater disposal system is (are) safe, functional and adequate
for the number of bedrooms and type of structure indicated herein. I further verify that based on the information
obtained from the Municipality of Anchorage files and from my investigation and inspection, the on-site water
supply and/or wastewater disposal system is(are) in compliance with all applicable Municipal and State codes,
ordinances, and regulations in effect at the time of installation.
Name of Firm Pannone Engineering Services LLCPhone (907) 272-8218
Address P.O. Box 100217, Anchorage Ak. 99510
Engineer's Printed Name Steven R Pannone
6. DSD SIGNATURE
System #1 Approved for bedrooms
System #2 Approved for bedrooms
Disapproved
Conditional approval for
Date 5/29/2014
. —SOFA Oli1
*'4▪ 9?H i iFAe
il • }even R.'Pannane
+a so: ▪ CE -8149 ow
Ikki,/*OfES9 -Or
bedrooms, with the following stipulations:
ON-SITE Ga.
WATER AND
"t7 WASTEWATCR ozz1
ponrRAM 1-775:,::'-,
By:
The uni
Original Certificate Date: !'
of '.chorage Development Services Division (DSO) issues Certificates of On -Site Systems Approval (COSA) based only
upon the representations given in paragraph 5 by an independent professional civil engineer registered in the State of Alaska. The Municipality
of Anchorage is not responsible for errors or omissions in the professional engineer's work.
7. ATTACHMENTS:
COSA Checklist X
Septic System Advisory
Well Flow Advisory
COSA blue sheet(c
Nitrate Advisory
Arsenic Advisory
Other
If more than 1 septic system is on the lot:
COSA Checklist # 1 of 1
Structure served by this system 1
Certificate of On -Site Systems Approval Checklist
Legal Description: Denaly, Block 1, Lot 24
A. WELL DATA
Well type Private If A, B, or C provide PWSID #
Date completed 8/8/2000
Total depth 171 ft.
Date of test
Static water level
Well production
Sanitary seal (Y/N)
Cased to 171 ft.
FROM WELL LOG
8/8/2000
Artesian
50+
ft.
g.p.m.
WATER SAMPLE RESULTS:
Coliform Neg colonies/100 mL Nitrate ND mg/L
Arsenic ND uglL Date of sample: 5/21 /2014
B. SEPTIC/HOLDING TANK DATA
Tank Type/Material Septic/Steel
Tank size 1,250 gal.
Number of Compartments 2
Foundation cleanout (Y/N)
Date of pumping 9/14/2013
C. ABSORPTION FIELD DATA
Date installed After 24i00
Length 50 ft.
Total depth 101 ft
Depression over tank (Y/N) N
Pumper JR's Pumping
Parcel ID: 067-062-04
Well Log (Y/N) Y
Wires properly protected (Y/N) Y
Casing height (above ground) 24
AT INSPECTION
9/18/13
Artesian*
3.2+
ft.
g.p.m.
Collected by: PES
in.
Date installed After 7/24/00
Cleanouts (Y/N) Y
High water alarm (Y/N) N
Soil rating (g.p.d./ft2 or ft2/bdrm) 1.2 GPD/SF
Width 5
Eff. absorption area 500 ftz
Date of adequacy test 9/18/13
System type Shallow Trench
ft. Gravel below pipe 4 ft.
Monitoring tube Y Depression over field
Results (Pass/Fail) Pass
Fluid depth in absorption field before test 0 in. Water added 614
Elapsed Time: 180
min. Final fluid depth 0 in.
Any rejuvenation treatment (past 12 mo.) (YIN & type) No
For 4 bedrooms
gal. New depth 0 in.
Absorption rate >= 600+
If yes, give date
g.p.d.
D. LIFT STATION
Date installed Size in gallons Manhole/Access (Y/N)
"Pump on" level at in. "Pump off' level at in. High water alarm level at in.
Datum Cycles tested Meets alarm & circuit requirements?
E. SEPARATION DISTANCES
WELL ON LOT TO:
Septic tank/lift station on lot 100+
Absorption field on lot 100+
Public sewer main 75+
Sewer /septic service line 25+
Animal containment areas 100+
On adjacent lots 100+
On adjacent lots 100+
100+
Public sewer manhole/cleanout
Holding tank 100+
Manure/animal excrete storage areas 100+
SEPTIC/HOLDING TANK ON LOT TO:
Building foundation 5+ Property line 5+ Absorption field 5+
Water main 10+ Water service line 10+ Surface water 100+
Wells on adjacent lots 100+
ABSORPTION FIELD ON LOT TO:
Property line 10+
Water Service line 10+
Curtain drain 50+
Building foundation 10+
Surface water 100+
Wells on adjacent lots 100+
F. COMMENTS
* Well Plug at 3 feet, assumed artesian
Water main 10+
Driveway, parking/vehicle storage 10+
G. ENGINEER'S CERTIFICATION
I certify that I have determined through field inspections and
review of Municipal records that the above systems are in
conformance with MOA COSA guidelines in effect on this date.
Engineer's Printed Name Steven R. Pannone
Date 5/29/2014