HomeMy WebLinkAboutEAGLE PARK BLK 1 LT 3agl Pa k lock I Lot 050-782 -03 Municipality of Anchorage Development Services Department Building Safety Division On-Site Water and Wastewater Program, 4700 EImore Road P.O. Box 196650 Anchorage, AK 99507 Page of www.ci.anchorage.ak.us (907) 343-7904 ON-SITE WASTEWATER DISPOSAL SYSTEM AND/OR WELL INSPECTION REPORT Permit Number: OSPl11169 PID Number: 050-782-03 Name: Troy Davis Homes, Inc. Wastewater System: [] New [] Upgrade Address: 165 E. Parks Highway Wasilla, AK 99654 ABSORPTION FIELD Phone: Number of Bedrooms: 357-9394 3 [] DeepTrench I~ Shallow Trench [] Bed [] Mound [] Other: LEGAL DESCRIPTION Soil Rating: Total Depth from odginal grade: 1.0 GPD/Ft2 7.5-8.2 Ft. Block: 1 Lot: 3 Subdivision: Depth to pipe bottom from odginal grade: Gravel depth beneath pipe: Eagle Park 3.5-4.2 Ft. 4 Ft. Township: Range: Section:Fill added above original grade: Gravel Length: 0 Ft. 60 Ft. Well: [] New [] Upgrade ereve~ width: Number of lines: I Distance between ii .... 5 Ft. 1I Ft. Classification (Private, A, B, C): Total Depth: Cased to: Total absorption area: Pipe Material: Class C Public Water System 360 Ft. 359 Ft. 600 Ft2 ASTM D3034 PVC Driller: Date Ddlled: Static Water Level: Installer: Date Installed: Alpine Drilling 5/2/07 287.6 Ft. Pomraning Excavation 10/24-25/2011 Yield: GPM Pump Set at: Ft. Casing Height Above Ground: 15 2 Ft. TANK SEPARATION DISTANCES [] Septic [] Holding [] S.T.E.P. [] Other: T~To Septic Absorption Lift Holding >ublic/Private Manufacturer: Capacity: Tank Field Station Tank Sewer Line Anchorage Tank 1,250 GaL Material: Number of Compartments: Well >150' >150' N/A N/A >25' Steel Two (2) ? Surface Water >100' >100' N/A N/A % / LIFT STATION f~ : Size: Manufacturer: Lot Line >5' J 7 N/A N/A Gal. "Pump on" level at: "Pump ofF' level at: High water alarm at: Foundation >5' > 10' N/A N/A in. in. in. / Pump Make & Model Electrical Inspections performed by: Curtain Drain None Noted Remarks: BENCH MARK Location and Description: Garage Slab. Assumed Elevation: 100.0 Ft. z: ·,. Engineer's Stamp Inspections performed by: s. Eng Dates: 1st 10/24/2011 2nd 10/25/2011 Development Services Department Approval Conditional Approval Date: ~fien~in J Schiller: "/2 : , : Reviewed and approved b e Permit Number: OSPl11169 Municipality of Anchorage DEVEOPMENT SERVICES DEPARTMENT 4700 Elmore Road Anchorage, AK. 99519-6655 - 343-7904 EAGI.E RIVER ROAD Page 2 of 3 PID NO.: 050-782-03 SBg*59'OO'E 150.00 4 ct.~ss c (~ EAGLE PARK SUBDMSION LOT 3, BLOCK I S1 IA Ia 117.2' 26.1' 20.4' 26.7' 31.5'125.7' 55.1' 62.6~ 4-9.9' 57.1' 2 F~r Bedroom 49-'r. ~ amin J Schiller.,' C4- e TH1 M1 e TH2 14 PLAN AS-BUILT SCALE 1' = 40' Municipality of Anchorage DEVEOPMENT SERVICES DEPARTMENT 4700 EImore Road Anchorage, AK. 99519-6655 - 343-7904 On-Site Wastewater Disposal System or Well Inspection Report Permit Number: OSPlll 169 Page 3 of 3 PID NO.: 050-782-03 /--100.1 / Existing I ~' Finished I 94.8 902 ,~98.3 Existing Grade E Finished Grade Geotextile Fabric Drainfield Rock 60' (Trench Length) 82.3' Groundwater 5/15/11 PROFILE AS-BUILT 99.0 No Scale 94.8 On-Site Wastewater Disposal System Permit MUNICIPALITY OF ANCHORAGE Development Services Department On-Site Water & Wastewater Program 4700 Elmore Road, PO Box 196650 Anchorage, AK 99519-6650 Telephone: (907) 343-7904 Permit Number: OSP111169 Tax Code Number: 05078203000 Work Type: Septic Initial Permit Effective Dates: August 01, 2011 to July 31,2012 Design Engineer: NORTH RIM ENGINEERING Subdivision: EAGLE PARK Site Legal Address: EAGLE PARK BLK 1 LT 3 G:0056 Owner/Address: GUNLOGSON MARVIN PO BOX 112442 ANCHORAGE AK 995112442 Site Mailing Address: 20633 MELODY LN, Eagle River Lot Size in Sq Ft: 46566 Total Bedrooms: 4 This permit is for the construction of: Y Disposal Field Y SepticTank N Holding Tank N Privy N Private Well N Water Storage All construction must be in accordance with: 1. The attached approved design. 2. All requirements specified in Anchorage Municipal code Chapters 15.55 and 15.65 and the State of Alaska Wastewater Disposal Regulations (18AAC72) and Drinking Water Regulations (18AAC80). 3. The wastewater code requires inspections during the installation. The engineer must notify the Development Services Department at least 2 hours prior to each inspection. Provide notification by calling (907) 343-7904 (24 hours). 4. From October 15 to April 15, a subsurface soil absorption system under construction during freezing weather must either: A. Open and Close on the same day. B. Covered, sealed, and heated to prevent freezing. Issued Date: ate: Community Development Department Development Services Division On-Site Water & Wastewater Program UNICiPALtTY OF ANCHORAGE Phone: ~07-343-7~04 Fax: Mayor Dan Sullivan ON-SITE SEWER/WELL PERMIT APPLICATION FOR A SINGLE FAMILY DWELLING Parcel I.D. ~5~" '7 ~Z'- Property owner(s) "-~o,.5, i~ Mailing address /g 5 ~, ~ ~3 ~r~ Site address ~¢~ ~ Legal description (Sub'd., Bloc~t Lot) Legal description (Township, Range & Secbon) Lot Size''~¢¢ ~¢ Sq. Ft. Number of Bedrooms Day phone ,¢(, LZ THIS APPLICATION ([~ all that apply) Absorption Field Septic Tank Holding Tank Privy Private Well IS FOR: THIS APPLICATION IS AN: Initial J~ Upgrade [] Renewal [] Water Storage [] THIS APPLICATION INCLUDES A VARIANCE / WAIVER REQUEST FOR: I certify that the above information is correct. I further certify that this application is being made for a Single Family Dwelling and is in accordance with applicable Municipal Codes. Signature-of property owner or aut~rized agent) Perm~Rush Fees: "'~-D~ate of Payment: Receipt Number: Permit No. L. -) Waiver Fees: Date of Payment: Receipt Number: Waiver No. G:\Building\On Site\Forms\Client Forms\Permit App_010411 .doc (Rev. 1/11 ) MEMO Steve Eng, PE, PH P.O. Box 770724, Eagle River AK 99577 (907) 694-7028 tel northrimeng@aol.com Date: 7/20/11 To: MOA On-Site Services Subject: Eagle Park S/D, Block 1, Lot 3 Septic System Design Number of Pages: 7 A new house and wastewater system are planned for the subject lot. The test hole showed excellent sandy gravel to 16.5 ', and a low groundwater level. The design calls for a new trench, new septic tank & private sewer lines. Private water wells serve the area lots and are shown in drawings. An existing Class C well is present on the lot. Lot is level terrain. Please review the wastewater system design & water well location for the single family home. I have included design plans & specs, design guidelines, & soil tests. If there is need for additional information or clarification please give me a call. Thanks-Steve MEMO Steve Eng, PE, PH P.O. Box 770724, Eagle River AK 99577 (907) 694-7028 tel northrimeng@aol.com Date: 8/1/11 Number of Pages: 4 To: Debby Wockenfuss, MOA On-Site Services Subject: Eagle Park S/D, Block 1, Lot 3 Revised Septic System Design Debby, After discussions with you, we propose to average the two percolation rates to 1.0GPD/FT2. 4 out of 5 perk tests in the immediate vicinity were in the 1-2 min/inch range. I also added topography & changed the soil tests per your request. Please issue the permit. Thanks-Steve Eagle Park S/D, Block 1, Lot 3 SPECIFICATIONS & DESIGN GUIDELINES Wastewater System Sizing: This is a new 4-bedroom, single family home. This is an established subdivision and most of the neighboring lots are developed. These lots are large and are served by private water wells & Class C wells. No adverse impacts are expected from development. No conflicts to the other lots will take place by this septic system and water well construction. The easements are located on the drawing and are not encroached upon. Soil tests revealed silty sandy gravel soil. An application rate of 1.2 GPD/FT2 with 0.5 reduction factor for utilizing a 5' wide trench. Trench Length = 600 FT2/5'x .5 reduction factor -- 50'; 1 line ~ 50'. No bedrock was encountered. Monitoring revealed groundwater ~ 16' in TH 1. Specification Requirements: All components and work must comply with the Municipality of Anchorage Specifications (AMC) & State of Alaska Drinking Water Regulations and Wastewater Regulations. · Two compartment, 1250 gallon septic tank. Watertight couplings on inlet & outlet. · 5' minimum between the tank and bed. 10' to property lines. · 3' of cover or insulation is required for trench; an equivalent of 1" insulation for 1' foot soil cover. · Tank & solid pipe must be set on well compacted, stable soil. · 4 inch diameter cleanouts with airtight caps are required 1' to 4' from foundation wall, prior to any 90 degree bend in 4 inch line, in each tank compartment, and two adjacent opposing cleanouts between the tank and the absorption field, not more than 10' from the tank positioned to provide cleanout access towards the tank and towards the absorption field. · All cleanouts must extend to at least ground level. · In solid pipe runs, ASTM D-3034 may be used in lieu of cast iron. · Trench to be placed level, minimum of 4' to groundwater, 6' to bedrock from drain- rock. · Drain rock to be ½ inch to 2 ½ inch screened. Drain rock to be distributed uniformly throughout the trench. · Perforated pipe to be installed level with perforations down. · Silt barrier (filter fabric) to be installed above the drain rock. · Smeared trench sides must be raked or scarified before drain rock placement. · The finish grade must be mounded to promote drainage over the trench. · Insulation must be placed over any pipe installed under driveways or parking areas. · Approved pipe materials include cast iron, PVC ASTM D3034, PVC ASTM F789, ABS ASTM D2661, · Sewer Service Line is minimum 2% slope. · Septic Tank to be pumped every two years or when required. · Insulation board to be extruded direct burial polystyrene (Dow Styrofoam HI/equal) Level Lo~ /~[ight Stope Bedrooms F.C.O. 1250 allon Septic Tank ~ Double C.O.'s -E CO MT/CO 30' Ecs( en~ Absorption Trench Alternate Site o ! iDESiGN NOTES: ~ [1. Total Depth of Trench is 7.5'. T,H,2 / Terrain is lev,?. Generally slop.es south. 2. Sewer Service Line minimum 2% slope. .3. Measure To Wells Prior To Construction. 4. Lot Served by Class C Well. 5. General Slope Is South Toward Eagle Rive ~,~ ~ 4/ ~% i = ~u ~'~"~~' .;~.~ E GLE PARK S/S WASTEWATER NO~ TH~IM ~ .. "~% A _C U c- C U c 0 c 0 ._C U C q- 0 -p c 0 I 0 ~ c (/)~ 0 CD L~ 0 c~ U 0 c- O 0 0 I, I +~ 0 (jO 0 0 (._) U O.J C~ CL 0 ¢" (D 0 0 U c- <:[ 0 06 '-~ OJ 0 u _.o >., '0 ui ~ c c~ ~ U II Z Ld ]Z Q) Z Ld Z [k CRTH IM ~ ,,E~INEERING SBILS LB(] - PERCBLATIBN TEST Dote Per¢ormed: 5/2/11 Per¢ormed For: Troy 3avis Legc~ Description~ Eagle Park S/D, BLock 1 Lot 3 DEPTH (FEET) 1 -- · - 4 - .. ;..,,......;'.,.. 6 - 7 - 8 - 9 - 10 - 11 - 1P - 13 - 14 - 15 - 16 - 17 - 18 - 19 - ~EO - E:I - Drganic GP Si["cy Sandy Grovel T,H, Location: See Attached Design Groundwater? No Depth Wo~er Depth AF"cer Moni"coring,16' Dc"ce: 5/15/11 ~ Dance Gross Time Ne~c Time Dep~ch Ne~c Drop 1 7/15 0 5,5" -- P 7/15 10 10 min, 10,5" 5,0" 3 7/15 1P 5,5" -- 4 7/15 PP 10 mir, 10,5" 5,0" 5 7/15 85 -- 5,5,, -- 6 7/15 35 10 min, 10,5" 5,0" 7 7/15 37 -- 5,5" -- 8 7/15 47 10 min, 10,5" 5,0" 9 7/15 50 -- 5,5- -- 10 7/15 60 10 min, 10,5" 5,0" Percolation Re"Ce 2 min,/inch Perc Hole Diameter Tes~ Run Between 3' and 4' Commen"cs: Presoaked. Measured "co nearest 1/16 inch, Shit I on Tn Mi-lA File, Per¢ormed By Nop"chRim Eng, I ~(~¢' CERTIFY THAT ~HIS TEST WAS PerFormed in Accordance with A(/ State/MunicipaL GuideEines in E¢¢ect BN THIS gATE, gATE: 7/15/11 7/15/11 I1 oF ~E SBILS LF1G - PERCEILAT]'BN TEST Dc-te Per?ormed: 5/2/11 Per.Formed For; Troy Dcvis Le9c[ Descrip-tion: Ecg[e Perk S/D, BLock 1 Lot 3 2) - 3 - 4 - 5 - 6 - 7 - 8 - 9 - 10 - 17 - 18 - PO - 2)1 - DEPTH (FEET) Brgo, nic GP Sit-fy T,H, Locc-tion: See A-t-tcched Design Scndy Grovel Groundwc~er? No Depth -- WoOer Depth AFSer Monitoring,none Dc~e: 5/15/11 v ~ Dc~ce Gross Time Ne~ Time Dep~ch Ne~ Drop 1 7/15 0 5,0" -- 2) 7/15 10 10 min, 10,0" 5,0" 3 7/15 12) 5,0,, -- 4 7/15 Pa: 10 min, 10,0" 5,0" 5 7/15 2)5 5,0" -- 6 7/15 35 10 min, 7 7/15 37 -- 5,0" __ 8 7/15 47 10 min, 10,0" 5,0" 9 7/i5 50 -- 5,0,, __ 10 7/15 60 lO min, 10,0" 5,0" PercoLc~cion Rc~e 2 min,/inch Pepc HoLe Dicme~cer 6" Test Run :Between 3' and 4' CommenCes: Pnesookeot, M¢omuped ~co neopes~c 1/16 inch..~oit I o9 In MOA FiLe, Per-Formed :ByNop-t;hRim En9, I ~ CERTIFY THAT THIS TEST WAS Per-Formed in Accordcince wi-th AI.t 3-to,-te/Municipo,[ Guide[ices in E.F.Fec-t FIN THIS DATE, DATE, 7/15/ll Rick Mystrom, P.O. Box 196650 Anchorage, Alaska 99519-6650 Mayor http:;;www.ci.anchorage.ak.us 343-4744 November 2, 1998 Marvin Cunlogson PO Box 112442 Anchorage, Alaska 99511 2442 Subject: Lot o4"Block I Eagle Park Subdivision Permit #SW970387, PID ~050-782-~0~ The subject permit, issued October 31, 1997 by this office for a single family well and/or on-site wastewater system, has expired as of October 31, 1998. A new permit must be obtained from this office for a well and/or on-site wastewater system NOT installed by the expiration date. If you have drilled the well, a well log must be sent to this office for documentation of the installation and to close the permit. If a licensed Professional Engineer has inspected the installation of the on-site wastewater system, the original as-built inspection report must be sent to this office for review, approval and documentation. Ail inspection reports must be submitted within 30 days of construction completion. When applying for a new permit, the fees are: $320.00 for an on-site wastewater permit; $120.00 for a well permit and $440.00 for a combined on-site wastewater and well permit. If~u have any questions, please call this office ac 343-4744. sinderely, / J~mes Cross, P.E. 1:~'ogram Hanager 0n-site Services eric: Copy of Permit cc: DH! Engineering Co PAGE i OF i MUNICIPALITY OF ANCHORAGE DEPARTMENT OF HEALTH AND HUMAN SERVICES P.O. BOX 196650, 825 "L" STREET, ROOM 502 ANCHORAGE, ALASKA 99519-6650 ON-SITE WASTEWATER DISPOSAL SYSTEM PERMIT PERMIT NUMBER:SW970387 DESIGN ENGINEER:DHI ENGINEERING OWNER NAME:SEAWARD REALTY CO OWNER ADDRESS:20634 EAGLE RIVER RD EAGLE RIVER, ALASKA 99577 DATE ISSUED:10/31/97 EXPIRATION DATE:10/31/98 PARCEL ID:05078203 LEGAL DESCRIPTION: EAGLE PARK BLK I LT 3 LOT SIZE: 46566 (SQ. FT.) NUMBER OF BEDROOMS: 3 THIS PERMIT: 3 THIS PERMIT IS FOR THE CONSTRUCTION OF: DISPOSAL FIELD /SEPTIC TANK SYSTEM ALL CONSTRUCTION MUST BE IN ACCORDANCE WITH: 1. THE ATTACHED APPROVED DESIGN. 2. ALL REQUIREMENTS SPECIFIED IN ANCHORAGE MUNICIPAL CODE CHAPTERS 15.55 AND 15.65 AND THE STATE OF ALASKA WASTEWATER DISPOSAL REGULATIONS (18AAC72) AND DRINKING WATER REGULATIONS (18AAC80). 3. THE ENGINEER MUST NOTIFY DHHS AT LEAST 2 HOURS PRIOR TO EACH INSPECTION. PROVIDE NOTIFICATION BY CALLING 343-4744 ( 24 HOURS ) (NOT REQUIRED FOR WELL ONLY PERMIT) 4. FROM OCTOBER 15 TO APRIL 15 a SUBSURFACE SOIL ABSORPTION SYSTEM UNDER CONSTRUCTION DURING FREEZING B. COVERED, SEALED AND HEATED TO PREVENT FREEZING THE FOLLOWING SPECIAL PROVISIONS. SPECIAL PROVISIONS: RECEIVED BY: ISSUED BY: DATE: DATE: /0--3/-- 77 DHI CONSULTING Civil ° Surveying ENGINEERS ° Planning SITE NARRATIVE Project: Eagle Park Subdivision, Lot 3 This project consists of a single lot (150' x 287') of 43,000 square feet. The proposed septic system is for a three bedroom, single family residence. Existing septic and residential wells service the lots to the south. A 100 right-of-way easement boarders the property to the north. The lot the east and west is owned by the developer and is under construction for a three bedroom single family house (septic system to be designed)· Well: Lot 3 is proposed to be serviced by a Class C well to be drilled on lot 3. Design and application forms have been completed and submitted to the Alaska Department of Environmental Conservation. ADEC Has issued a permit approving construction of the system. The proposed well location will not have an adverse affect on adjacent properties. Septic System: As stated above, lots to the south have existing septic systems. The lots to the east and west are proposed to have a septic system for three bedrooms. The proposed septic for lot 3 is a wide trench, 57 feet long which sets about 30' from the south property line. There is adequate room for the proposed system and one replacement system. The proposed septic system doesn't impact the ability of adjacent lots to install or replace their septic system. Drainage: The subject lot has a gentle slope to the north (about 3%). There are no steep grades or ravines on the site. Surface drainage from the lot is collected in the road side ditch along Eagle River Road. Areas disturbed by this improvements are to receive top soil and seeding. No other drainages or ponds exist within 100 feet of the property. Dimond Center Tower, 5th Floor · 800 E. Dirnond Blvd., Suite 3-545 · Anchorage, Alaska 99515 (907) 344-1385 * Fax 344-1383 'Permit No~ ? Municipality of Anchorage Department of Health and Human Services ENVIRONMENTAL SERVICES DIVISION P.O. Box 196650 · Anchorage. AK 99519-6650 ° Tel: 343-4744 Well & On-Site Wastewater Disposal System Legal Description: LOT 3 BLOCK I EAGLE PARK SUBDMSION PID No. Page I of 6 W.O. 97,317 Dale 9-17-97 SYSTEM DESIGN CALCULATIONS 1. NO. BEDROOMS = ,3 2. USE WIDE TRENCH WITH 4' OF GRAVEL .3. PERCOLATION RATE= 8.7 MIN/INCH 4. ABSORPTION AREA = (# BEDROOMS)(150 GPD/BR) TRENCH APPLICATION RATE X (REDUCTION FACTOR) = (3)(150) X 0.5 = 282 S.F. .80. 5. LENGTH OF TRENCH= ABSORPTION AREA 282 TRENCH WIDTH 5 = 57 LINEAL FEET PERCOLATION RATE MIN/INCH 0-1 1-5 PIT & TRENCtl APPLICATION RATE MOUND & BED APPLICATION RATE * [ 6-15 16-30 31-60 CREATER THAN 60 FILTER LAYER 317MSG2D CPD/SF GPD/SF NOT SUITABLE NOT SUITABLE 1.2 0.8 0.8 ] 0.5 0.6 0.4 0.45 0.3 NOT SUITABLE NOT SUITABLE 1.0 .7 'Permit NO. ? Municipality of Anchorage Department of Health and Human Services ENVIRONMENTAL SERVICES DIVISION P.O. Box 196650 ® Anchorage, AK 99519-6650 ® Tel: 343-4744 Well & On-Si[e Was[ewater Disposal System Legal Description: LOT 3 BLOCK 1 EAGLE PARK SUBDMSION PID No. Page 2 of 6 W.O. 97517 Date 9-17-97 NOTES: 1 2 3 4 5 6 7 8 9 ALL CONSTRUCTION SHALL BE IN ACCORDANCE WITI-I CHAPTER 15.65. WASTEWATER DISPOSAL REGULATIONS OF THE MUNICIPAL CODE AS CURRENTLY AMENDED. INSTALL NEW 1000 GAL. SEPTIC TANK AS SHOWN ON THE DRAWINGS. SET TANK LEVEL & RECORD INLET AND OUTLET ELEVATIONS OF THE TANK. TANK SHALL BE PLACED ON UNDISTURBED NATIVE SOIL. PLACE OUTSIDE PROTECTIVE WELL RADIUS. EXISTING STRUCTURES. WELLS, SEPTIC SYSTEMS OBSERVED WITHIN 200' OF PROPOSED SYSTEM SITE ARE SHOWN ON DESIGN DRAWINGS. ANY DEVIATION FROM THE DESIGN MUST BE AUTHORIZED BY THE ENGtNEER PRIOR TO ITS INCORPORATION INTO THE SYSTEM. CONTRACTOR TO LOCATE ALL UNDERGROUND UTILITIES, PROPERTY UNES, EXISTING WELLS, WATER WAYS, SURFACE AND SUBSURFACE DRAINAGE FACILITIES, LAKES, PONDS, AND OTHER FACILITIES REQUIRING SEPARATION DISTANCES FROM THE PROPOSED SEPTIC SYSTEM. CONTRACTOR TO STAKE PROPOSED SYSTEM PRIOR TO CONSTRUCTION. NOTIFY THE ENGINEER OF' ANY OBSERVED CONFLICTS PRIOR TO CONSTRUCTION. NOTIFY THE ENGINEER AND DHHS 24 HOURS PRIOR TO COMMENCING WITH CONSTRUCTION. A MINIMUM OF THREE INSPECTIONS ARE REOUIRED. THE FIRST INSPECTION SHALL BE OF THE SUBGRADE, PRIOR TO PLACING SAND FILTER. THE SECOND INSPECTION SHALL BE AFTER THE PLACEMENT OF GRAVEL, DISTRIBUTION PIPING, STANDPIPES. TANK, AND OTHER COMPONENTS AS SPECIFIED. THE THIRD INSPECTION SHALL BE AFTER THE WORK IS COMPLETED. CONTRACTOR SHALL DELIVER TO THE ENGINEER A SET OF RED-UNED, AS-BUILT DRAWINGS SHOWING ALL DATA AS SPECIFIED IN SEC. 15.65.F. 2, 5, 4, 5, 6 OF MUNICIPAL WASTEWATER DISPOSAL CODE WITHIN FIVE DAYS OF THE FINAL INSPECTION. INVERTS AND SWING TIE LOCATES SHALL BE TO THE NEAREST TENTH OF A FOOT. THESE AS-BUILTS SHALL BE USED BY THE ENGINEER TO PREPARE AND SUBMIT RECORD DRAWING TO DHHS. STAKE ALIGNMENT OF SYSTEM WITH MARKERS SHOWING THE PROTECTIVE DISTANCES FROM WELLS AND OTHER BODIES OF WATER PRIOR TO BEGINNING INSTALLATION. ALL EXCAVATION DEPTHS ARE ADVISORY. THEY ARE TO BE VERIFIED AND MAY BE MODIFIED BY THE ENGINEER IF ACTUAL FIELD CONDITIONS VARY FROM "{HOSE USED TO PREPARE THE DESIGN. Permit Municipality of Anchorage Department of Health and Human Services ENVIRONMENTAL SERVICES DIVISION P.O. Box 196650 * Anchorage, AK 99519-6650' Tel: 343-4744 Well & On-Site Wastewater Disposal System Legal Description: LOT 3 BLOCK 1 EAGLE PARK SUBDMSION PID No. Page 4 of 6 W.O. g7517 Date 9-16-97  PROPOSED 'C' WELL I I kOT 5 LOT 4 EAGLE 5PROPOSED 'C' WELL I LOT RIVER ROAD LOT 2 ( WELLo---'--~ SYSTEMS (.%?T,O. I S PTq c sYs 1, LOCATION OF EXISTING SYSTEMS ARE APPROXIMATE ONLY. INFORMATION OBTAINED FROM DRAWING PREPARED BY S ENGINEERING DATED 6-2-97, VISUAL FIE~ OBSERVATIONS, ~ ~fes~e . AND DHHS RECORDS DATE ~~'=~ · Permit No. Municipality of Anchorage Department of Health and Human Services ENVIRONMENTAL SERVICES DMSION P.O. Box 196650 * Anchorage, AK 09519-6650' Tel: 343-4744 Well & On-Site Wastewater Disposal System Legal Description: LOT 3 BLOCK 1 EAGLE PARK SUBDMSION PID No. Page 5 of 6 · W.O. 97517 Date g-18-97 'C' WELL SSC~OO'OO'E NOTES: 1 ~0.00 CLASS 1. WATER TO BE PROVIDED FROM CLASS 'C' WELL TO BE LOCATED ON LOT 5 BLOCK 1 EAGLE PARK SUBDIVISION. LOT 3 OPOSED HOUSE -- THIS AREA INSTALl. FOUNDATION I 1,000 GAL. ~ INSTALL ~ SEPTIC TANK OPPOSING UTILITY & ALLEY [ RESERVE EASEMENT ~ TRENCH 57 SCALE: 1"=50' CE 5807 DATE 317k4SG1D ; 'Permif Nc~. q~ Municipality of Anchorage Department of Health and Human Services ENVIRONMENTAL SERVICES DIVISION P.O. Box 196650' Anchorage, AK 99519-6650 ° Tel: 343-4744 Well & On-Site Wast°water Disposal System Legal Descripfion: LOT 3 BLOCK 1 EAGLE PARK SUBDMSION PI0 No, Page 6 of 6 W.O. 97317 Dale 9-17-97 TH#$B ORGANIC MAT 4" PVC MONITORING TUB 4" CLEAN OUT AS SHOWN ON PLAN & PROFILE SLOPE FINISH GRADE TO PREVENT PONDING OVER TRENCH '~ NON COMPACTED BACKFILL GROUND JRBED TRENCH WALLS -~ FILTER FABRIC ~'"--~' PERF. PVC SEPTIC ROCK SEPTIC SLIGHTLY SILTY SANDY GRAVEL (12 TO 15% SILT' DENSE-DRY ROCK TO 8" TYPICAL WIDE TRENCH SECTION NTS SCALE: NTS 517MSG6D DEPARTMENT OF HEALTH & HUMAN SERV1CES 801L8 LOG-PERCOLATION TEST 14 TEST HOLE 3A~ ~.~ PERFORMED FOR: TOM SEAWARD DATE PERFORMED: 9--6--97 , t?/'/; LEGAL DESCRIPTIoN:LOT 5 BLOCK 1 EAGLE PARK SUBD. ~ 6' ORGANIC MAT. 7 /...~;,~., GRAVEL W/ORGANIC SILT 2 ,/,,? :/ (REDDISH)-SOME ROOTS SLOPE SITE PLAN 3 9,. ,/,./ /// 4 ~,,x'./ ..1~- 5 .>O<% : 4 /'/ /~.// 7 2 :/{),; ; ~"' /:'/'2 8 ;,?/? S~LTY SANDY CR^V~L ~ ~ ~/ / ,'~ ROCK TO 24' VERy DENSE DRY -- /,/ / WAS CROUND WATER S 10 ~ ~ .,~ ENCOUNTERED ? NON-C L /' ~ IF YES. AT WHAT 11 ~// _ p DEPTH ? E -~ .~ '/- OE,TH oF WATER 12 /.././ · .- AFTER MONITORING ? ~03~.- DATE: / / ~./,/ 2 s-s-97 3(~,llu. e' 4 1/16' 17 18 19 .£RCOLATION RATE: ~.? (~INUT[$/INC~.) PERCHOLE DrAMETER: 6' 20 TEST RUN DE'T'WSEN: 7.0 FT. AND 7.5 F'T .... COMMENTS:SOILS PERSOAKED 'PRIO~ START PERFORMED DY: DEE HIQ'U ~_ CERTIFY THAT THIS TEST WAS PERFORMED IN ACCORDANCE IMTH ALI STATE AND MUNICIPAL CUIDEUNES IN EI~I~K.~ ON THIS DAI'~, DATE:.<~° 3~"~' ! 317C*rR.3D TE:5'r EIOLE: 3B ~' ...... '" .... PERFORMED FOR: TOM SEAWARD DA'I~ PERFORMED: 9-6-9'/ ~.~ ..... . .~'\~'~",.. · IFC:AL DESCRIPTIoN:LOT 3 BLOCK 1 EAGLE PARK SUBD. ~ ORGANICS / ./, ~ SLOPE SI~ P~N 2 ~.~'~ ? ~,: /. .~ F,~,..~ SUGHIY S:L~ SANDY - (12 TO 15~ 8 ~.~/ DRy ROCK ~0 2'/[ ~ WAS CROUND WA~R S 10 ~,y;/ ENCOUN~RED ? NONE L ~1 ~' ~'~ IF ~S, AT ~{AT 0 P ~.~.~ OEPm ? E 12 ~'/~ DEPm OF WA~R ~.(~ AFaR MONITORING ~ 0.4' - DATE: 9-19-97 d./'/.. · , 0~-,~ J ,,:,s ,' J ,' 14 15 ~'('~ 17 18 19 PERCO~ON RA~: ~.9 (MINU~S/INCH.) PERCHOLE DIAME3ER: 20 TEST RUN BE~EN: 6' ~T. AND 6.5' ,~. CO~EN;s:~LEPHON~ LIN~ 22' ~R~ LIN~. (I~' Or WATER DRAINED IN LESS ~AN 30 MIN.) PERFORMED BY: DEE HIGH A~ STA~ AND MUNIOPAL ~ID~NES [~C{ ~IS DA~ DA~'~*~'~7 317C~4D £AC;LE RIVER ROAD I LOT 4 I I LOT 3 LOT 2 (~Dm' CONSULTING ENGINEERS CIVIL · SURVEYING · PIAN~IN~ Telephone: (907)344-13~6 J*&~: (00'/)344-1383 w.o. 973J7 Icoup' £tL£ 317CTE7DI$CA~l.=lO0, [DATE 9--8--97 TEST HOLE LOCATION LOT 2, 3 & 4 BLOCK 1 EAGI,E PARK SUBD. Municipality of Anchorage Development Services Department Building Safety Division On-Site Water and Wastewater Program 4700 Bragaw Street P.O. Box 196650 Anchorage, AK 99519-6650 www. muni.org/onsite (907) 343-7904 CERTIFICATE OF ON-SITE SYSTEMS APPROVAL FOR A SINGLE FAMILY DWELLING Parcel I.D. 050-782-03 .¸ GENERAL INFORMATION Complete legal description LocatiOn (site address): Expiration Date: Lot 3, Block 1, Eagle Park Subdivision 20633 Melody Lane Eagle River. AK 99577 Current Property owner(s) Troy Davis Homes, Inc. Mailing address 165 E. Parks Highway Wasilla, AK 99654 ~_ending agency Day phone 357-9394 Day phone Mailing address 2: 3. Real Estate Agent .,rvfaiji .h'g ~!dd¥.e~ss 'Unless otherwise re'quested, COSA will be held by DSD for pickup. NUMBER '0i~' BEDROOMS: Four (4) TYPE OF WATER SUPPLY: Individual Well' [] Individual~Water Storage [] Community Class c Well [] Public Water System [] Day phone TYPE OF WASTEWATER DISPOSAL: Individual On-site [] Individual Holding Tank [] Community On-site [] Public Sewer [] The Municipality of Anchorage Development Services Department (DSD) issues Certificates of On-Site Systems Approval (COSA) based only upon the representations given in paragraph 4 by an independent professional civil engineer registered in the State of Alaska. Certificates of On-Site Systems Approval are required for the transfer of title (except between spouses) for properties served by a single-family on-site wastewater disposal and/or water supply system. DSD also issues COSAs upon request to homeowners. Certificates of On-Site Systems Approval are valid for 90 days from the date of issue for properties served by a private or Class C well and may be reissued with new water sample results. (Certificates may be reissued for-a period of up to one year with valid water samples.) Certificates are valid for one year for properties served by Class A or B wells or a public water system. The Municipality of Anchorage is not responsible for errors or omissions in the professional engineer's work. 4. STATEMENT OF INSPECTION BY ENGINEER As certified by my seal affixed hereto and as of the'validation date shown below, I vedfy that my investigation, based on procedures outlined in the Certificate of On-Site Systems Approval Guidelines for this application, shows that the on-site water supply and/or wastewater disposal system is (are) safe, functional and adequate for the number of bedrooms and type of structure indicated herein. 1 fbrther verify that based on the information obtained from the Municipality of Anchorage files and frOm my investigation and inspectiOn, the on-site water supply and/or wastewater disposal system is(are) in compliance with all applicable Municipal and State codes, ordinances, and regulations in effect at the time of installation. Name of Firm Anderson Engineering Phone 522-7773 Address P.O. Box 240773 Anchorage, AK 99524 Engineer's Printed Name Benjamin Schiller, P.E. Date 12/19/2011 DSD SIGNATURE ~"/' Approved for Disapproved. Conditional approval for .. $~en~in J Schiller bedrooms. '*~2"-?b~/~..."-~ bedrooms, with the following stipu~auons: ~";,t,~'V:,.'... ON-SITE WATER AND WA~T~w~ER . PROG~M ..' Attachments: COSA Checklist Septic System Advisory Well Flow Advisory Nitrate Advisory X Arsenic Advisory Maintenance Agreements Supplemental Engineer's Report Other (Rev. 11/05) Original Certificate Date: /c~. - ~ ~-~,~//~ Municipality of Anchorage Development Services Department Building Safety Division On-Site Water & Wastewater Program 4700 Bragaw Street P.O. Box 196650 Anchorage, AK 99519-6650 www. muni.org/onsite (907) 343-7904 CERTIFICATE OF ON-SITE SYSTEMS APPROVAL CHECKLIST Legal Description: Lot 3, Block 1, Eagle Park Subdivision A. WELL DATA Well type C~ass C IfA, B, or C provide PWSID #~ Date completed 10/5/2005 Sanitary seal (Y/N) Y Total depth 360 ft. Cased to 359 ft. FROM WELL LOG Date of test Static water level ft. Well production g.p.m. WATER SAMPLE RESULTS: Coliform 0 colonies/100 mL Nitrate .15 mg/L Arsenic: N/D mg/I Date of sample: 7/13/11 B. SEPTIC/HOLDING TANK DATA Tank Type/Material Septic/Steel ' Tank size 1,250 gal. Number of Compartments Two Foundation cleanout (Y/N) Y Depression over tank (Y/N) N Date of pumping New ConstrUction Pumper C. ABSORPTION FIELD DATA Date installed 10/24-25/11 Soil rating (g.p.d./ft2 or ft2/bdrm) 1.0 GPD/SF Length 60 ft. Width 5 ft. Totaldepth 7.5-8.2 ft. Eft. absorption area 600 ft2 Monitoring tube~ Date of adequacy test New Const. Results (Pass/Fail) __ Fluid depth in absorption field before test in. Water added Elapsed Time: ~. min. Final fluid depth Any rejuvenation treatment (past 12 mo.) (Y/N & type) Parcel ID: 050-782-03 Well Log (Y/N) Wires properly protected (Y/N) Casing height (above ground) AT INSPECTION 7/13/2011 287.6 ft. 15 g.p.m. Y >24 in. Other bacteria 0 colonies/100 mL Collected by: Anch. Well and Pump Date installed 10/24/2011 Cleanouts (Y/N) Y High water alarm (Y/N) N System type 5' Wide Trench Gravel below pipe 4 ft. Y Depression over field. N For bedrooms ~gal. Newdepth. in. in. Absorption rate >= g.p.d. If yes, give date LIFT STATION Date installed "Pump on" level at__ Datum in. E. SEPARATION DISTANCES Size in gallons "Pump off" level at Cycles tested in. SEPARATION DISTANCES FROM WELL ON LOT TO: Septic tank/lift station on lot >150' Absorption field on lot >150' Public sewer main N/A Sewer/sePtic service line >25' Animal containment areas >50' Manhole/Access (Y/N) High water alarm level at Meets alarm & circuit requirements? in. On adjacent lots >150' On adjacent lots >150' Public sewer manhole/cleanout Holding tank N/A Manure/animal excrete storage areas N/A >100' SEPARATION DISTANCES FROM SEPTIC/HOLDING TANK ON LOT TO: Building foundation >5' Property line >5' Water main N/A Water service line >10' Wells on adjacent lots >100' SEPARATION DISTANCE FROM ABSORPTION FIELD ON LOT TO: Property line ~ 7 '~ Building foundation >1o' Water Service line >1o' Surface water >1oo' Curtain drain None Noted Wells on adjacent lots >1oo' COMMENTS: Absorption field >5' Surface water >1o0' Water main >10' Driveway, parking/vehicle storage >25' G. ENGINEER'S CERTIFICATION I certify that I have determined through field inspections and review of Municipal records that the above systems are in conformance with MOA COSA guidelines in effect on this date. Engineer's Printed Name Benjamin Schiller, P.E. Date 12/19/2011 COSA Fee $ Date of Payment Receipt Number (Rev. 11/05) %*. %J._Benja Schiller Waiver FeeS ~ -- Date of Payment ~ ~ )~ t ~ ~ ~ R o ipt t Municipality of Anchorage P.O. Box 196650 ® 4700 Elmore Road Anchorage, Alaska 99519-6650 · (907) 343-7904 · Fax (907) 343-7997 ,http:llwww.muni.orfllOnsite Development Services Division On-Site Water and Wastewater Proqram )epartment **** VARIANCE/WAIVER REVIEW **** Waiver#: osp111353 COSA#: osc111487 PID#: 050-782-03 Legal Description: Eagle Park B-1 L-3 Engineer: Anderson Engineering Permit#: ospl 11169 Applicant: Troy Davis Your request for a waiver of the required 10 feet horizontal separation from the absorption field to the property line has been approved. The approved separation distance is 7.0 feet. This waiver approval applies to the existing absorption field only. Any future upgrade to the on- site wastewater disposal system will require all separation distances be met or another approval from this department. [---] The affected adjacent property owner(s) have been given a 7 day notice regarding this waiver. [~] Notarized letter(s) of nonobjection have been received from the owner(s) of the affected adjacent property. Adjacent properties are not affected by this waiver. Waiver is Granted: X Waiver is not Granted: Date: /o~.-~.."7~/[ Approved by: ~ ~N'arn~C(Reviewer Rec#: 04621G Amount: $200.00 Date Paid: 12/21/11 **** VARIANCE/WAIVER REVIEW **** Lot Block 1 has 46,080.4 Sq. Ft. of Area 50' EAGLE RIVER ROAD S89°59'00~£ i50,00 50' 3,0 FOR: Troy Davis Homes Date Scale 10--18--11 1' = 30' LanMark ~rid ~s-~u,~* S~£i~ee~£ · Su.eying, Inc. NW056 211 O106 9330 Vanguard Drive, Suite 803 Anchorage, Alaska 99507 IDrawn by ]Field Book (90*) SS~-60~0 CEF 288 ] hereby certify that the property described hereon has been surveyed by me, or at my direction, and that the improvements situated thereon are within the property lines and do not overlap or encroach on the property Iying adjacent thereto unless otherwise shown. That no improvements on the property lying adjacent thereto encroach on the premises in question and that there are no roadways, transmission lines or other easements on said property except as shown. It is the responsibility of the owner or builder, prior to construction, to verify proposed building grade relative to finish grade and utility connections and to determine the existence of any easements, covenants or restr et oas wh ch do not appear on the recorded subdivision plat. Listed distances prevail over scaling. Reproduction may cause distortion. Legal Description I Block Lot 3 EAGLE PARK SUBDIVISION Y 10/31/2011 22:18 90724307~2 $G$ R.f./~ 1113 ]45001 Client Name Anchorage Well &Pum, p Matrix Drin~ng Water Sample Remarks: Paralllet~r Resalis Arsenic ND Ni~ato-N 0.150 Microbiolog~ La~oratory F~. Coil Total Coliform ;. 0¢ AWPS, INC. PAGE 83/85 Printe~ Date/Time Collected Date/Time Received Date/Time Technical Director Method Container ID ug/L EPg00.8 mg/~ EPA 300.0 07/20/2011 13:25 07/13/2011 16:25 07/14/2011 9:00 Stephen C. F_ale ~dlowable Prep Anal~is Limit~ Date Date 07/18/11 07/19/11 NRB 07/14/11 07/14/11 8DP 100mL 8M20 9223B 100mL SM20 9223B A 07/14/1I DLC 07/14/1I DLC ANDERSON ENGINEERING P.O. BOX 240773 ANCHORAGE, AK 99524 522-7773 677-7766 (FAX) MEMORANDUM DATE: December 22,2011 TO: Jeff Poet FROM: Mike Anderson, P.E. SUBJECT: Lot 3, Block 1, Eagle Park Subdivision Inspection Report/COSA Representatives of Anderson Engineering met on site today along with City personnel to inspect the absorption trench recently constructed on the subject lot. An excavator owned and operated by Pomraning Excavation was utilized to expose the trench to verify it was constructed in conformance with the approved plans and the Municipal Ordinance governing septic systems. The inspection verified the septic system was completed in accordance with the plans and meets all requirements of Municipal Code. We recently certified the construction of the septic system with the submittal of the inspection report and the Certificate of On Site System Approval. We hereby request these documents be approved by the City as submitted. To: Affected Property Owner Adjacent to Lot 3, Block 1, Eagle Park Subdivision Subject: Waiver Notification To Whom It May Concern: The Municipality of Anchorage On-site Water & Wastewater Program (On-site) regulates private drinking water wells and septic systems for single family residences in accordance with Anchorage Municipal Code (AMC) Chapters 15.55 and 15.65. The Chapters include minimum separation distance requirements for private drinking water wells and septic systems. The requirements represent a conservative approach to protecting public health. Occasionally, the construction or upgrade of a property's well or septic system cannot be accomplished without reducing the code required separation distances. In these situations, a waiver to the required separation distance may be approved if an Alaska licensed civil engineer can successfully show that the public health will be maintained. The code requires an absorption trench to be located a minimum of 10 feet from any lot line. The subject property owner's engineer has formally requested a waiver be granted to allow the absorption trench to be 7 feet from the west lot line located on Lot 2, Block 1, Eagle Park Subdivision. On-site has reviewed the engineer's request and supporting documents, and is satisfied that the public health will be maintained with the reduced separation distance. A waiver approving the requested separation distance will be issued in accordance with the code. AMC 15.65.140 requires all adjacent property owners be notified seven (7) days prior to issuing a separation distance waiver. This letter and a copy of the have been sent to you in accordance with this requirement. I have read the above and have no objection to granting the waiver allowing the absorption trench to be within 7' of my property line. Date: Notary Certification: OFFICIAL SEAL~{