HomeMy WebLinkAboutEAGLE PARK BLK 2 LT 8
/:~a,,? MUNICIPALITY OF ANCHORAGE
lCi
DEPARTMENT OF HEALTH & ENVIRONMENTAL PROTECTION
ENVIRONMENTAL ENGINEERING DIVISION /~ ~ /
825 L Street- Anchorage, Alaska 99501 Telephone 264-4720
ON-SITE SEWAGE DISPOSAL SYSTEM AND/OR WELL INSPECTION REPORT
NAME
MAILING ADDRESS
.EGAL DESCRIPTION
. capacity in gallons IF HOMEMADE: I Inside length
DISTANCE TO: I Dwelling
Manufacturer
Wed
DISTANCE TO:
No. of lines ~1 Length of each line
Top of tile to finish grade ,~, ~) I
Width
Dwell'ng~'~ ~'e r.~-~
Width ~
Foundation ~..~ / Nearest lot line
Total length of I'nes I ~Z~:~ inches
· '"~--~ ~1 Trench width
NO. OF BEDROOMS
PERMIT NO.
No. Of compartments
Liquid depth
PERMIT NO.
Liquid capacity in gallons
:PERMIT NO.
Distance between lines/~.p/4
Total e{fective absorption area
PERMIT
Type of crib
DISTANCE TO:
DISTANCE TO:
Well
Building foundation
OTHER
PIPE MATERIALS 4
~ RATING
Crib depth
Building foundation
D~stance to lot line J PERMIT NO.
Septic tank J Absorption area(s)
At<,..
APPROVED
72-013 IRev. 3178)
DATE
LEGAL
GREATr'~ANCHORAGE AREA BOROtTH
Department of Environmental Quality
3330 C Street
Anchorage, Alaska 99503
INSPECTION REPORT ON-SITE SEWAGE DISPOSAL SYSTEM
NAME ~ ~'~ MA~UNG ADDRESS £~'./~ ~ ~ ~- ~,o~
SEPTIC TANK:
DISTANCE
FROM WELL
INSIDE LENGTH
MANUFACTURER
INSIDE WIDTH
LIQUID DEPTH
NUMBER OF
COMPARTMENTS
LIQUID CAPACITY /~00 GALLONS.
SEEPAGE PIT:
NUMBER OF PITS
LINING MATERIAL
BUILDING FOUNDATION__ NEAREST LOT LINE "~'! .
DIAMETER ~" OR WIDTH LENGTH__, DEPTH ~:;~'
LO~'/~'~F--C'I~'SIZE: DIAMeTER__DEPTH (,O . DISTANCE FROM:
TOTAL EFFECTIVE
ABSORPTION AREA (WALL AREA) ~'~"~"'
WELL
ADDITIONAL ABSORPTION
WELL:
TYPE
BUILDING
FOUNDATION
CESSPOOL
APPROVED~I~
CONSTRUCTION
DEPTH ~'~a DISTANCE FROM:
SEPTIC ~/ SEEPAGE /~7/
TANK , SYSTEM
NEAREST
LOT LINE
OTHER SOURCES
DISAPPROVED
NEAREST
SEWER LINE
REMARKS
DISTANCES:
INSTALLED BY.'
DIAGRAM OF SYSTEM
PIPE MATERIALt.
LOT SLOPE=
REMARKS=
Fo~m No. EQ-O31
PERMIT NO.
MUr4I C I~qL I TY OF Ar4CH~RAGE
DEPARTMENT k HEALTH AND ENVIRONMENTAL ..~OTECTION
825 'L' STREET, ANCHORAGE, AK. ~9501
264-4720
ON--SITE SEWER UPGRADE PERMIT
( 800593 )
APPLICANT
LOCATION
LEGAL
GEORGE WADE
PTARMIGAN DRIVE
~IL 8~B~2"EAGLE'PARK'~D~
207 N. L BLVD ~950~
LOT SIZE
43450 SQUARE FEET
TYPE OF SOIL ABSORPTION SYSTEM IS: TRENCH
MAXIMUM NUMBER OF BEDROOMS
SOIL RATING
THE REQUIRED SIZE OF THE SOIL ABSORPTION SYSTEM IS:
DEPTH---- 10 LE~,~GTH= 25 GRAVEL DEPTH= 6
THE LENGTH DIMENSION IS THE LENGTH (IN FEET) OF THE TRENCH OR DRAINFIELD.
THE DEPTH OF A TRENCH OR PIT IS THE DISTANCE BETWEEN THE SURFACE OF THE
GROUND AND THE BOTTOM OF THE EXCAVATION (IN FEET).
THERE IS NO SET WIDTH FOR TRENCHES.
THE GRAVEL DEPTH IS THE MINIMUM DEPTH OF GRAVEL BETWEEN THE OUTFALL PIPE
AND THE BOTTOM OF THE EXCAVATION (IN FEET).
REQU I RED SEPT I C TANK S I ZE= $00 GALLO~4S
PERMIT APPLICANT HAS THE RESPONSIBILITY TO INFORM THIS DEPARTMENT DURING THE
INSTALLATION INSPECTIONS OF ANY WELLS ADJACENT TO THIS PROPERTY AND THE
NUMBER OF RESIDENCES THAT THE WELL WILL SERVE.
T&.~O ( ~ > I ~4SPECT I 0~4S ARE REQU I RED
BACKFILLING OF ANY SYSTEM WITHOUT FINAL INSPECTION AND APPROVAL BY THIS
DEPARTMENT WILL BE SUBJECT TO PROSECUTION.
MINIMUM DISTANCE BETWEEN A WELL AND ANY ON-SITE SEWAGE DISPOSAL SYSTEM IS
100 FEET FOR A PRIVATE WELL OR i50 TO 200 FEET FROM A PUBLIC WELL DEPENDING
UPON THE TYPE OF PUBLIC WELL
MINIMUM DISTANCE FROM A PRIVATE WELL TO 8 PRIVATE SEWER LINE IS 25 FEET 8ND
TO A COMMUNIT~ SEWER LINE I~ 75 FEET.
OTHER REOUIREMENT~ MAY 8PPL~. SPECIFICATIONS 8ND CONSTRUCTION DIAGRBMS 8RE
AVAILABLE TO INSURE PROPER INSTALLATION.
PERMIT EXPIRES DECErIBER
I CERTIFY THAT
l: I AM FAMILIAR WITH THE REQUIREMENTS FOR ON-SITE SEWERS AND WELLS AS SET
FORTH BY THE MUNICIPALITY OF ANCHORAGE.
2: I WILL INSTALL THE SYSTEM IN ACCORDANCE WITH THE CODES.
~: I UNDERSTAND THAT THE ON-SITE SEWER SYSTEM MAY REQUIRE ENLARGEMENT IF THE
RESIDENCE IS REMODELED TO INCLUDE MORE THAN ~ BEDROOMS.
S I GNED: .....
APPL I CANT
ISSUED BY--.
GEORGE WADE
V4. 0
DEPARTMENT CgF--.,%HEALTH RH[J'ENYIROtlf'IENTFIL ~TECTIOtl ~ 825 "E STF:EET, AtICHOPAOE, AK. 9.9L
I,IELL FIr-ID
PE~.MIT NO. (
· PLICA T
tPE OF SOIL ABSORPTION SYSTEM
264-47"20
Ob..I--$ "r TE --c':.EI4ER PEAr,1 'r T
LOT SIZE W3 f'¢-~'~¢
',I:4IMUH IIUItBER OF BEDROOMS
SOURRE FEET
SOIL RATING (SO FT?BR): /Oc'b
tE P,EQUIRED SIZE OF THE SOIL ~DSORPTION SYSTEM IS:
( ~
.EF.-T-I_I=~ /(.) LEI~IOT,-I=~:~ ! ORI---I%"EL ['EPTH---' G
THE LENGTH DIMENSION IS THE LENGTH (IN FEET) OF TftE TREtlCH OR DRRINFIEL[~.
THE DEPTH OF R TRENCH OR PIT IS THE DI~%RNCE E:ETWEEN THE SURFACE OF THE
GROUtlD Arid THE DOTTOH OF THE EXCAVATION (IN FEET).
THERE IS fl0 SET WIDTH FOR TRENCHES.
THE GRAVEL DEPTH IS THE MINIMUM DEPTH OF GRAVEL EETWEEN THE OUTFRLL PIPE
AND THE BOTTOH OF THE EXCRVRTION (IN FEET).
:EQU [ RED 5EPTI C TRNt~ ~ ~ ~E=. ~ ~3~ LC~b~
:F:HIT APPLICANT HR5 THE RESPONSIBILITY TO INFOR~~PRRTHENT [~.ff<INQ THE
~STRLLRTION INSPECTIONS OF ANY [4ELL~ ADJACENT TO THIS PROPERTY RNC, THE
]MBER OF RESIDENCE5 THAT THE HELL HILL ~ERVE.
----- TI,lO ( 2 > I tqSPECT I 0~45 RES REQL~ I RED ------
tCKFILLIt~O OF ANY SYSTEM WITHOUT FINAL IHSPECTION RHD RPF'ROVRL BY THIS
{PRRTHENT WILL BE SUBJECT TO PROSECUTION.
:NIMUII DISTANCE BETWEEN R WELL AND RNY ON-SITE SEWRGE DISPOSRL SYSTEM IS
~0 FEET FOR R F'RIVRTE HELL OR ~50 TO 200 FEET FROM fl PUBLIC HELL DEPEHDIfI6
)ON THE TYPE OF PUBLIC HELL.
;NIHUM [~ISTRflCE FROM ~ PRIVATE HELL TO fl P~IVRTE ~EHER LINE I~ 25 FEET fine,
~ fl COMMUNITY SEHER LINE IS 75 FEET.
;LL LOGS fl~E PEQUIRED fiND MUST E:E ~ETU~NED TO THE DEPRRTMEflT WITHIN 20 DRYS
' ~HE HELL COMPLETION.
'HEP. P`EOUIREMENTS MflY flPPLY. SF'ECIFICRTIONS fiND CONSTRUCTION DIRGRRH3 RP`E
*AILflDLE TO INSURE PROPER INSTflLLRflON.
PERf'I I T EX.P I RE--'5~ Drc- '~IEr'IBIER 3:1_.. :1.980
CERTIFY THAT
I AM FArllLIRR WITH THE P, EQUIP`EMENTS FOR ON-SITE SEWERS AND HELLS RS SET
~RTN DY THE MUNICIPALITY OF ANCHORAGE.
I HILL INSTALL-THE SYSTEM Itl ACCORDANCE WITH THE CODES,
I UriDEF:STANC, THAT THE ON-SITE SEI4ER SYSTEM' MAY P. E6¢UIRE ENLARGEMENT IF THE
-:SIDEf~CE IS PEMODELED TO INCLUDE MORE THAN :~ ~EDROOMS.
V4. 0
GREATER ANCHORAGE ArEA BOROUGH
SEWAGE DISPOSAL SYSTEM -- APPLICATION AND PERMIT
pERMIT NO.
OTHER
FINAL INSPECTION: ~'4 HOUR NOTICE REQUIRED. BACKFILLING OF' ANY SYSTEM WITHOUT FINAL INSPECTION BY THE
DEPARTMENT OF' ENVIRONMENTAL QUALITY AUTHORITY WILL BE SUBJECT TO PROSECUTION,
TAN'< TO
SEEPAGE P'? 20!
DRAIN PIELD
SEEPAGE PiT
DIAGRAM OF SY~I'~M
// /
II III It IIIII
I II II I II I I I
III II I II I I I
III II I II II I
III IIIIIIII
GREATER ANCHORAGE AREA BOROUGH
DEPARTMENT OF ENVIRONMENTAL QUALITY
3330 "C" Street
ANCHORAGE, ALASKA 99503
Case
Performed For "~. c-~L~ .D~t~d Performed ~//~/7_~
Legal Description: Lot
This Form Reports Soils Log y Percolation Test__
- Soil Test Must Be Logged To 4' Below Proposed Seepage System -
Depth
Feet Soil Characteristics
11--
13--
14--
Was Ground Water Encountered?
If Yes, At What Depth?
Reading Date Gross Time Net Time Depth to H20 Net DroF
I
Percolation Rate Minute
Proposed Installation: Seepage Pit Drain Field
Depth of Inlet Depth to Bottom of Pit or Trench
Test Performed BY~ Date Certified BY:
Date:
Parcel I.D.
On-Site Services Section ' ' '"
". P.O. Box 196650 Anchorage, Alaska ,.99519-6650 '
. · .~.~ ~. ;, :..;~ .... ~. ' 343-4744 ":.'~ ' :' ;. '
" CERTIFICATE oF HEALTH AU'~iORITY
APPROVAL FOR A SINGLE FAMILY DWELLING
MUNICIPALITY OF ANCHORAGE
DEPARTMENT OF HEALTH & HUMAN SERVICES
Division of Environmental Services
GENERAL INFORMATION '*
{;omplete legal description ~-
Location (site add)ess or directions)
-- Property owner
Mail'ing 'addreSs.
Lending agehcy. Day phone
Mailing address
Agent ~/~ ~
Address
Unless othe~ise requested, HAA will be held for ptckup. ~ ~ ~ ~ -
2. NUMBER OF BEDROOMS:
TYPE OF WATER SUPPLY:
Individual well
Com. munity well
Public water-·
NOTE:-.'If com~n~nity well ~ystem,~ provide written.~Snfirmation from 'Stat? iADEC 'a. t!est- .
lng to the legality and status of system. ' ' -_..
4. TYPE OFWASTEWATER DISPOSAL:
... '~ ~. , . ·In, dividual ?.n-site ,.~..
.. Communityon-stte · , . .... ,,"
"*''' '"'~"' P'ublier,:< .... '
' ' ' ' csew
· ' NOTE: If community wastewater system, provide written confirmation from State A C
attesting to the legality and status of system.
: :',: '.T" Engi
6,' "' DHH$ SIGNATURE ....
'i Approval
· 'i; ;' and their lending
Municipality of Anchorage
Department of Health & Human Services
HEALTH AUTHORITY APPROVAL CHECKLIST
Legal Description: Z.,~ ~,~ ~'""/~/'~' ,~A,~',~ $/-,'~Z:P'Parcel I.D. O,5'4::3 ~',~'~_. ~-'~
A. WELL DATA
Well type ,~,'~"'~. If A, B, or C, attach ADEC letter.
Log present (Y/N) ~/
Sanitary seal (Y/N) ~
Date of test
Static water level
FROM WELL LOG ,4,///~
Well flow g.p.m.
ADEC water system number
Casedto ~ v''/- Casing height
AT INSPECTION '
Pump level
SEPARATION DISTANCES FROM WELL TO: /~,,~4.~ p.~/,~/.~_~/~ ,,~-~;-~-
Septic/holding tank on lot ~ ~o,~) .,. ; On adjacent lots
~ ~1~ ' ~
Absorption field on lot ' : -/~ ""~. :-~f...Onadjacentlots~/7/Z~7/~/z~'~
Public sewer manhole/cleanout
Petroleum tank
Public sewer'main ,,,r/,/~
Public sewer service'line
WATER SAMPLE RESULTS:
Coliform ~ ,~',,,4 ~.~"
Date of sample: ~ .''//
Nitrate
B. SEPTIC/I. H3~-~tN~I'TANK DATA
Date Installed ~<-c,o?,,/ /q~-<;~, Tank size ., r · ~q Comp aments ~ ~'
Cleanouts (Y/N) ~ Foundation cleanout (Y/N) ~ Depression (Y/N) *~
High water alarm (Y/N) ~ .... Alarm tested (Y/N)
Dateof pumping /~/~ ~~'~'~' :' ' ' -' ' ' "'
SEPARATI~ DISTANCES FROM SEPTIC/HOLDING TANK TO:
Well(e) on lot ~' ~o ~.~ On adjacent lotsc ~ ~ - 4 ?-Z~Foundation ~ ~
To prope~yline ~/~ Absorption field ~/~ Water main/se~ice line ~
Sudace water/drainage ' ~'~? ~'[~"" *~ ' ~"' ~
CONTINUED ON BACK PAGE
72-02~ (Rev. ~1) Fronl MOA 21
STATION
Date installed
Size in gallons
Vent (Y/N)
"Pump on" level at
High water alarm level
Manufacturer
.Manhole/Access (Y/N) -.
· "Pump off" level at
Cycles tested
Meets MOA electrical codes (Y/N) ' '
SEPARATION DISTANCE FROM LIFT STATION TO:
Well on lot On adjacent lots
D._'AB$'ORPTION FIELD DATA
.~:~' Date installed ,~',"?-~','~'~ / ~'~
_~'. Length ~,5" / Width -~ ·'
Total absorption area D'~ .
Depression over field (Y/N) ~/
Resu ts (pass/fail). '_~::"~' ~ ~; ' ' '
Soil rating. /OOJ"r/~;~:3ystem type
Gravel thickness 7' "'
Cleanouts present (Y/N)
Date of adequacy test
.... ~or '.
Total depth /4::~ /
......... bedrooms
Peroxide'treatment (past 12 months) (Y/N) ;,4./~ ;' ' - If yes; give date
..SEPARATION DISTANCE I~ROM ABSORPTION FIE~D'TO:' ,. , ' ;. - ....
· .~. ' . . 4.~...,?.~4~. - · ....
Wellonlot /,~' ~ Onadjacentlots/-''7~O~' ~.~,/?J'J-~Prope. rtyline ~-~'"~
To building foundation
On adjacent lots. ~. ,-~'- Z ~'~ ~_..
Surface water ~
Curtain drain .,,~/,,~
E. ENGINEER's cERTIFICATION'
To existing or abandoned system on lot
.Cutbank "Y/','~ Water main/service line c~'~
Driveway. paHdng/vehicle storage area. ~
I certify that I have checked, verified, or conformed to all MOA and HAA guidelines In effect ~ the'date Of. this inspection.
Surface water
HAA Fee $
Date of Payment
Receipt Number
Waiver Fee: $
Date of Payment
Receipt Number
AS-BUILT
I hereby certify tha: I have surveye~ the follow~ng
Anchorage Recordln~: Precir. ct. ALaska. and that the
!,rnpro~,'ernent3 $1tLlate¢! thereon are w~thin the property'
lines and do not overlap or encroach on the property
lying adjacent thereto, that no improvement~ (~n prol~-
erty lying adjacent thereto en~roac.~ on the prermses in
.quest/on and that there are no roadways, transmls.~ion
lines or nther %'L'llble easements Oil said property except
a~ indicated hereon.
Dated at Eagle ltlver,
'ROBERT C. JOII'~SON
SCALE: , Registered L~nd ~urveyor ~0, 880-LS
1' =/r~ Box 451;. Eac:e FAver, Alaska
Phone
CHEMICAL & GEOLOGICAL LABORATORY
A DIVISION OF COMMERCIAL TES'[1NG & ENGINEERING
A~A~ISIS ~EPORT l! SUOLE Eot WORRozdez! 3S098
Date ~epozt Pstnted: ~ 12 91 I 16:0S
Client Sample ED:HELL HATEE Ut~EEATED L8
P~ID :UA
Collected JU~ 1l 9[ I 09:06
~ecetved 3~ 11 91 ! 10:0S
P~esszved vtth :AS
Client HaM :HAIR! BATES TECK. SERVICE
Client Acct
~eq !
Cha~tab ~ef l: 912627 Lab Snpl ID: 1 I~trix: WATEg
Allowablo
Pasametez Tested ~esult gnttl Method Limits
MIT~ATE-N 5.2 ~/1 KPA 3S3.2 10
~ample EOOTIHE SABLE COLLECTED EX: HAR~T BATES, WZTHE$SED E! PEGGY
EoM~kI:
I Tests PeZiOZMd See Special lnstzuctions Above UA-Unavailable
ND- None Detected ** See Sample ~emalks Above
~A- Not Anal/~ed LT-Less Than, GT-Gseatez Than
i~ MUNICIPALITY OF ANCHORAGE
DEPARTMENT OF HEALTH AND ENVIRONMENTAL PROTECTION
DIVISION OF ENVIRONMENTAL HEALTH
CERTIFICATE OF INSPECTION FOR HEALTH AUTHORITY APPROVAL
OF ON-SITE SEWER AND WATER FACILITY
264-4720
Application Date
GENERAL INFORMATION
(a) Legal Description (include lot, block, subdivision, section, townshipIrange)
Location (address or directions)
(b) Applicant Name ~ "~.l~..-~., Telephone: Home Business
Applicant Address ~--'"lO ("~~--~ -~::::Z,~,I-~_.~ ~-~V~
(c) Applicant is (check one): Lending Institution []; Owner/builder r-I; Buyer I-t; Other,,~ (explain);
(d) Telephone
Lending Institution
Address
(e) Real Estate Company and Agent ~"~"~"~ '"' ~
Address ~ ~ ~ v~
Telephone IO~ ~J~ ~'' ~ (-1 J)--
(f) tr'~e HAA to the followin~ address:
TYPE OF RESIDENCE
Single-FamilyE~- Multi-Family
Number of Bedrooms ~
Other
WATER SUPPLY
Individual Well ~ Community I-I Public r-I
Note: If community well system, must have written confirmation from the State Department of Environmental Conservation
attesting to the legality and status.
4, SEWAGE DISPOSAL
Onsite~ Publicr'l Community[] Holding Tank []
Note: If community well system, must have written confirmation from the State Department of Environmental Conservation
attesting to the legality and status.
72425
Page I of 2
5.' ENGINEERlNG FIRM PROVtDING INSPECTIONS' TESTS' FILE SEARCH' DAlI A AND INFORMATION
As certified by my seal affixed hereto and as of the validation date shown below, I verify that my investigation of this Health
Authority Approval shows that the on-site water supply and/or wastewater disposal system is safe, functional and adequate
for the number of bedrooms and typ~ of structure indicated herein. I further verify that based on the information obtained
from the Municipality of Anchorage files and from my investigation and inspection, the on-site water supply and/or
,,Nastewater disposal system is in compliance with all Municipal and State codes, ordinances, and regula?ons in effect on
the date of this inspection.
Name of Firm
Address · r."~ ,~ *,c ~.
Date F~, ?~ma?~
Telephone
DHEP APPROVAL ' ·
,'Approved t,or ~z~u~ ~'..~!' bedrooms by
Approved ~ "" ' Disapproved Conditional
Terms of Condltiona~l,~;p;~val
Date
CAUTION
The Muncipality of Anchorage Department of Health and Environmental Protection (DHEP) issues Health Authority
Approval certificates based solely upon the representations given in paragraph 5 above by an independent professional
engineer registered in the State of Alaska. The DHEP does this as a courtesy to purchasers of homes and their lending
institutions in order to satisfy certain federal and state requirements. Employees of DHEP do not conduct inspections or
analyze data before a certificate is issued. The Municipality of Anchorage is .not responsible for errors or omissions in the
professlonal engineer's work.
Page 2 ol 2
72-025 (11/84)
MUNICIPALITY OF ANCHORAGE (MOA)
HEALTH AUTHORITY APPROVAL (HAA)
CHECKLIST - FEBRUARY 1984
NOV 1 8 l 5'
2 ,2o VED
Legal Description:
WELL DATA
Well Classification
Well Log Present (Y~
If A, B, C, D.E.C. Approved (Y/N)
Date Completed _A~_/~..~ l~'~g Yield
Depth of Grouting '"'--
Tota Depth - ca t.o,
Static Water Level ' [~-~
Casing Height Above Ground ~ ~ 7.., a
Electrical Wiring in Conduit ~N)
~paration Distances from Well:
To Sept~c/~ Tank on Lot ~ ~
Pump Set At
Sanitary Seal on Casing~N)
Depression Around Wellhead (Y/~
; On Adjoining Lots
To Nearest Edge of Absorption Field on Lot j/.~ t ; On Adjoining Lots'
To Nearest Public Sewer Line t~/r~ To Nearest Public Sewer
Cleanout/Manhole t3/~ To Nearest Sewer Service Line on Lot
Water Sample Collected by ~ '~, ~-~ ~ t ~'"%'t~l'"sr-' ; Date ~ ~' ' % [ -
Water Sample Test Results ~ ~'~-~'~'~'~-.~
Comments A. ~/~- ~JI~'L,~ '"/-~'~.-r" ~-,z-t.o~.~_~E~'> -/-)~,
B. SEPTIC/HOL-Dff~K~ TANK DATA
Date Installed ~' ~e,t,. t'~Size [~C:)O '~ No. of Compartments
Standpipes (~I/N) Air-tight Capsd~N)
Depression over Tank
Pumping/Maintenance Contract on File (Y/N)t3
/
Holding Tank High-Water Alarm (Y/N) !/3,
Foundation Cleanout ~/N)
Date Last Pumped [~-I'~-~
;for ~"
Temporary Holding Tank Permit (Y/N)
Separation Distances from Septic/,la~
TO Water-Supply Well -- ~" ~:::~ct qJ ~J ~ ~0 Building Foundation ~'
TO Prope.y Line l~ ~'+ ~ TO Disposal Field
To Water Main/Se~i~ . t~ ~ ~ To Stream, Pond, Lake, or Major Drainage
. Course ~/~
Comments
Page I of 2
72-026(1t~84)
ABSORPTION FIELD DATA
Soils Rating in Absorption Strata
Dale Installed I~[ ~,
Widlh of Field
I
~ ~'c:'"=l='l~JA~' Type of System Design
Length of Field ~--~.~
Depth of Field
..- ' ~ Gravel Bed Thickness
Square Feet of Absorption Area~,,,"5~-"~ d~.~-~.a_~-Ii.. IsC~a~d~ipes Present~'N)
Depression over Field (Y~ ~/~3 "7 Z.- ~/'~'~Date of Last Adequacy Test.
Results of Last Adequacy Test ['~ tJ~D, 5~.1
Separation Distance from Absorption Field:
To Water-Supply Well
To Building Foundation
Lot
TO Water Main/Se~ice Line
To Stream/Pond/Lake/or Major Drainage Course
To Driveway. Parking Area. or Vehicle Storage Area
Comments
TO Property Line I ~,...~1 ~
To Existing or Abandoned System on
; On Adjoining Lots ~
To~Cutbank (if present)
D. LIFT STATION
Date Installed
Size in Gallons
"Pump On" Level at
High Water Alarm Level at
Tested for
Electrical Codes (Y/N)
Comments
Dimensions
Manhole/Access (Y/N)
"Pump Off" Level at
Vent (Y/N)
Pumping Cycles during Adequacy Test. Meets MOA
** Check Permitted Bedroom Rating Against HAA Request **
I certify that I have checked, verified, or conformed to all MOA and HAA guidelines in effect on the date of this inspection.
Signed G ,~ ~.,_,~E~,.,I~L;_,[, ~-,, ,~.~ Date
P y
Date of Payment
Amount: $
MOA No..,~"~'--~O ..~
Page 2 of 2
/ unicipalitYo¥
Anchorage
P.O. BOX 6650
ANCHORAGE, ALASKA 99502-0650
(907) 264-4111
TONY KNOWLE$.
MA YOR
DEPARTMENT OF HEALTH & HUMAN SERVICES
December 10, 1985
Mr. Robert Shafer
S & S Engineering
SRB 196-X
Eagle River, Alaska 99577
Subject: Lot 8 Block 2 Eagle Park Subdivision
Dear Mr. Shafer:
This Department grants the waiver of separation to 99 feet
from the 500 gallon tank to the well. This waiver is granted
for a four(4) bedroom single family dwelling only.
Sincerely,
Susan E. Oswalt
Environmental Quality Program Manager
On-site Services
SEO/lJw
HEALTH AUTHORITY
APPROVALS
SEWER & WATER
MAtN EXTENSIONS
SEWER S WATER
INSPECTION
ENGINEERING STUDIES
AND REPORTS
WELL INSPECTION
& FLOW TEST
SITE flt. ANS
SOIL TEST
PERCOLATION
TEST
STRUCTURAL&
MECHANICAL
INSPECTIONS
ON SITE
WASTE WATER
CtSPOSAhSYSTEM
DESIGN
ROBERTA. SHAFER
November 16 1985
Municipality of Anchorage
Department of Health and Human Services
825 L Street
Anchorage, Alaska 99501
CIVIL ENGINEEM
694-2979
NOV
REFERENCE: Lot 8; Block 2; Eagle Park Subdivision
·
Request you issue the attached Health Authority Approval and g~ant a
waiver to the horizontal separation distances between the septic tank "' _
and the on-site well. There are two s~ptic tanks, one was installed
in 1973 with a horizontal separation distance of 89 feet. A second
500 gallon septic tank was installed as a part of an upgrade of the
system from three bedrooms to four bedrooms in October 1980. The horizontal
separation distance on this tank is 99 feet.
There is no well log available for the well on this property drilled
in 1973. However, a well log for the well on the adjacent property,
drilled in 1979, is provided. The static water level in the existing
well on property is approximately 72 feet from the top of the well casing
and the well depth is approximately 128 feet. The topography between
the well and the on-site disposal system is a +20% in the direction
of the well.
In accordance with the risk analysis performed by us it would appear
that there is no bacteriological pollution possible and for this reason
it is our opinion that the horizontal distances prescribed by 18AAC72.021
is not required in this case.
If we may be of further assistance, please contact us.
SRB 19~X EAGLE RIVER, ALASKA 99577
="' DA~'E RECEIVED /' /'
INSPECTION APPOINT~MENTS
TIME TIME TIME
DATE DATE DATE
INSPECTOR INSPECTOR INSPECTOR p~
MUNICIPALITY OF ANCHORAGE MUNI~P~
DEPARTMENT OF HEALTH & ENVIRONMENTAL PROTECTION DE~, OF HEALTH
825 L St~t - Anchor~, Alike ~1 '
ENVIRONMENTAL SANITATION DIVISIONSEP
Tele~one ~7~
MAILING ADDRESS
PffiOPE~TY ~ESIDENT Iit difleren~ from'~bo~ ~ ~ PHON~
' MAILING ADDRESS
5. LEGAL pESCRIPTION ,.~)
STREET LOCATI(JN /. /t I~ J
5. ~YPE OF RESIDENCE ' , NUMSER OF~SEDROOMS
D One ~ Four . [] Other
,~ [] Two Five
SINGLE
FAMILY
[] MULTIPLE FAMILY [] Three [] Six
7. WATER SUPPLY
INDIVIDUAL* * ATTACH WELL LOG. A well log is required for all wells drilled
COMMUNITY since June 1975. For wells drilled prior to that date, give well
i'-I PUBLIC UTILITY depth (attach log if available.)
8. SEWAGE DISPOSAL SYSTEM
I~ INDIVIDUAL/ON-SITE*' /q~'"'~).YEAR ON-SITE SYSTEM WAS INSTALLED.
[] PUBLIC UTILITY
NOTE: THE iNSPECTION FEE MUST ACCOMPANY EACH REQUEST BEFORE PROCESSING CAN BE INITIATED.
~/ THIS SIDE FOR OFFICIAL USE ONLY
1. TYPE OF RESIDENCE NUMBER OF BEDROOMS
i'--I SINGLE FAMILY i-'l ONE. f-) THREE ~--I FIVE I-'1 OTHER
[] MULTIPLE FAMILY [] TWO [] FOUR [] SIX
2. WATER SUPPLY PERMIT NUMBER
[] INDIVIDUAL DEPTH OF WELL
[] COMMUNITY
DATE DRILLED
[] PUBLIC UTILITY
Connection Verified LOG RECEIVED
3. SEWAGE DISPOSAL SYSTEM PERMIT NUMBER
[]INDIVIDUAL/ON -SITE DATE INSTALLED
[]PUBLIC
UTILITY
Connection Verified
INSTALLER
[]Septic Tank or r-IHolding Tank
Size: J ~'L'~(~) If Tank is homemade SOILS RATING
give dimensions:
TYPE OF TANK MANUFACTURER
TOTAL ABSORPTION AREA MATERIAl.
Absorption Area lo nearest Lot Line
5. COMMENTS
[~"~APPROVED
FOR . ~ BEDROOMS
[] CONDITIONAL APPROVAL (letter must accompany certificate)
[] DISAPPROVED
DATE BY
72-010 (Rev. 6/79)
Fir. George Wade
Ptarmigan Drive
Eagle River, AK 99577
Re: Adequacy Test for Existing Septic System on
Lot 8, Biock 2, Eagle Park Estates.
Dear Mr. Wade:
At the request of your agent, Ms. Margie Lugo, our office conducted
a percolation adequacy test on your existing septic system at the
above-referenced location during the per/od October 11 & 12, 1980.
Your septic aystem is reported to consiet of a 1000-gallon septic
tank and a aeepage pit.
The septic tank had been pumpted and refilled with fresh water prior
to the percolation test. Slnce the 4-bedroom house had been occupied
up to the time of the test, a normal degree of saturation within the
leach field is assumed.
In accordance with the Anchorage Municipal Code, Chapter 15.G5,
Waste Water Disposal Regulations, any on-site sewage disposal
system "shall have adequate capacity to properly dispose of the
maximum daily sewage flow." The maximum daily flow is computed
at 75 gaIlons per capita-day (gcpd). Since "the population of
dwellings shall be estimated at two persons per sleeping room,"
the maximum daily sewage flow for your 4-bedroom house is 600
gallons per day (gpd).
To test the soil absorption capacity as well as the surge
capability of your system, fresh water was added in 50-gallon
increments to the seepage pit. The water was obtained from your
on-site private well at its maximum sustained rate of about ~
gallon8 per minute (gpm). The liquid levels were monitored closely
to detect any backup in the septic system.
Mr. Nade
October 13, 1980
Page -2-
The attached Table of Test Data represents the depths of
liquid in the septic tank and seepage pit, and the quan-
tities of water added. The septic tank was determined to
be 7.3 feet deep (bottom of tank to ground surface) with an
initial depth of 3.7 feet in the tank. The seepage pit was
measured to be 10.1 feet deep with an initial depth of 5.3
feet. Ground elevation at the septic tank standpipe is
approximately 2 to 3 feet above the seepage pit standpipe.
The attached Summary of Test Results indicates that the
liquid level in the seepage pit at the beginning of testing
on Day 2 fell to its initiai static level on Day 1, during
a recovery period of 24 hours. The test was terminated with
the introduction of 234 gallons of water due to the seepage
pit filling twice.
Based on this testing, an average percolation rate for your
existing septic system of at lest 230 gpd is indicated. Since
an on-site sewage disposal system for a 4-bedroom dwelling must
be capable of disposing of 600 gallons of sewage per day, your
septic system does not appear to be functioning satisfactorily
at this time.
Many factors affect the operation of a soil absorption type
of sewage disposal system. Soil type, groundwater depth,
age and history of maintenance of the system, and types of
waste are a few. This test has been performed in an attempt
to determine actual soil absorption capabilities of your
septic system under normal useage by considering the degree
of saturation of the leach field and surge loads that might
be imposed on the system. This test can only evaluate appar-
ent performance at a given point in time, and cannot deter-
mine either the condition of the leach field, seepage pit or
other components of the septic system, or the depth of the
water table;
We appreciate the opportunity given to perform this adequacy
test. If you have any questions regarding this test, please
contact this office.
Very truly yours,
ALASKA SOILS INVESTIGATIONS
Stephen D. Shrader, P.E.
ProJect Manager
Hr. Wade
October 13,
Page -3-
1980
ASI
No. 02180
Wtr Added, Seepage Pit
Rise in Seepage Pit
Rise in septic Tank
Gallons Wtr Added per
Ft of Rise (gal/ft)
SUHMARY OF TEST
Day 1
2~4 gal
4.9 feet
0.0 feet
RESULTS
D~_2
Recovery Time between Test (Hours)
Drop in Pit during
Recovery
Average Rate of Fall (ft/hr)
Average Absorption Rate
(gal/day)
24 hours
4.9 feet
Est. 2~4
Adequacy Test for Existing Septic System
O~ner: Mr. & Hrs. George Wade
Address: Ptarmigan Blvd.
'T~egal Description: Lot 8, Block 2,
Components Of Septic System:
Number of Bedrooms: 4
How long vacant:
Test performed by: Clayton Racca Jr.
Initial Static Levels: Septic Tank 3.74'
Project No.
Eagle Park Estate-
Septic Tank; Seepage.Pit
Occupied prior to test: Yes X No
Last pumped: 10/80
Water meter/S.N. 22812186
; Seepage Pit 5.26'
02180
TEST DATA
~,.. '. r' - ~-'r, Liquid ~Depth, ft. '.'~ Water Meter
Time Septic Tank. SeepaEe Pit Added, gal ReadinE, gal Remarks
1:20 3.74 5.26 -0- 0026137 10/11/80
1:25 3.74 5.26 -0- 0026137
2:00 3.74 7.27 50 0026187
2:15 3.74 8.12 50 0026237
2:30 3.74 9,14 50 0026287
2:55 3.74 9.32 50 0026337
3:03 3.74 10.14 17 0026354 Pit Filled up
3:30 3.74 " 10.14 17 0026371 Pit Filled up
4:20 3.74 7.1 L~v~ck
:00 3.74 5.2 lo/12/,o
1. Approval requested by:
Mailing Address:
2~ Property Owner:
Mailing Address:
GREATER ANCHOPJkGE AREA BOROUGH
Department of Environmental Quality
3330 "C" Street, Anchorage, Alaska 99503 274-4561
Date Received 4/?/?5
Time of Inspection
Date of Inspection
REQUEST FOR APPROVAL OF
INDIVIDUAL SEWER & WATER FACILITIES
FOR
Spokane )~rtgage Co
523 ~ 8th Ave 99S01
Phone:
George ~/ade Phone:
3. Legal Description:
4. Location: PtamtiganBlvd.
.5. Type of facility to be inspected
6. Well Data:
A. Type Drilled
C. Construction Standard
e
Lot 8~ Block 2, Eagle Park Subdivision
Eagle ~ver
Single No. of bedrooms S ~
B. Depth 128'
D. Bacterial Analysi~~
Sewage Disposal System:
A. Installed 1973
C. Septic Tank: 1. Size
4/8/7S
B. Installer R.B. l~oods
1000 gals 2. Manufacturer Stack Steel
O. Seepage Pit: 1. Absorption Area 372 sq.ft. 2.
E. Disposal Field: Total length of lines
Distances:
A. Well to: Septic tank ~:89!.~
Nearest lot line
B. Foundation to septic tank~.' ..~
C. Absorption area to nearest lot line
, Absorption area
, Other contamination
, Absorption area
2S'
Material Concrete
127' , Sewer Lines
EQ-034
{l/74) '
Page 1 of two pa~ec
'Legal Description
Loc 8, Block 2, . .Eagle P~rk Subdivision.
Comments ·
· · /-)z'? /~' ./~
' ' ~/ ' Approval kVal~d for one year from date signed
~ Greater'Anchorage Area Borough, Depar~ent of [nvtro~ental Quality
DIAG~M OF SYSTEM
I certify that the information contained in this request for approval to be a true .and
accurate representation of the subject sewer and water facilities and these facilities
are operating satisfactorily.
SIGNED ' Date
EQ-034 (1/74)