ON-SITE WASTEWATER DISPOSAL SYSTEM AND/OR WELL INSPECTION REPORT
Permit Number: OSPllll42 PID Number: 050-782-25
Name: Kelly Donovan Wastewater System: [] New [] Upgrade
Address:
20613 Ptarmigan Blvd, Eagle River, AK 99577 ABSORPTION FIELD
Phone: Number of Bedrooms:
~ [] Deep Trench [] Shallow Trench [] Bed [] Mound [] Other:
LEGAL DESCRIPTION Soil Rating: Total Depth from original grade:
Block: Lot: Subdivision: 1.0 GPD/Ft2 10,0 Ft.
Depth to pipe bottom from original grade: Gravel depth beneath pipe:
2 11 Eagle Park 5 - 7.4 Ft. 6.0 Ft.
Township: Range: Section:
Fill added above original grade: Gravel Length:
0 Ft. 50 Ft.
Well: [] New [] Upgrade Gravelwidth: Numberoflines: J Distance between lines:
5 Ft. I[ 0 Et,
(.;lasslrlcat~on (Private, A, B, L;): I oral Ueptiq: ~Jased to: Total absorption area: Pipe Material:
Existing Ft. Ft. 600 Ft2 D3034
Driller: Date Drilled: ~Statlc Water Level: Installer: Date Installed:
Ft. Fiintstone Construction 7/18/2011
Ft.] Ft. TANK
GPM
SEPARATION DISTANCES
~ [] Septic [] Holding [] S.T.E.P. [] Other:
TF'~ ~Urom~ $~p[;o Ab~o~p;.;ufi L;rt HuldiH9 :ubiiuiFdv,~tu Manufacturer:
Tank Field Station Tank Sewer Line
Capacity:
Existing 1000 Gal.
Well 100' 100% 100'+ NA 25'+ Material: Number of Compartments:
Plastic 2
Surface Water 100'+ 100'q- 100'-{- NA LIFTSTATION
Lot Line 5*q- 5~-F 5~+ NA Size: Manufacturer:
Gal.
Foundation 5~q- 10~+ 5'+ NA "Pump on" level at: "Pump off' level at: in. High water alarm at:
in. in.
Curtain Drain /~IA * 50~q- NA NA Pump Make & Model Electrical Inspections performed by:
Diverter valve and cleanout pipes installed for existing BENCH MARK
leachfield. Location and Description:
Garage Floor
Assumed Elevation:
100 Ft.
Engineer's Stamp
Inspections performed by: ArcTerra Dates: 1ST & 2ND 7/18/2011
3RD 7/20/2011
Development Services Department Approval
Reviewed and approved by: /~...'~'~_~.~. j/.l~, )'"""~t..~. Date: ~-~ ~
AS-BUILT SYSTEM DETAILS/SITE PLAN
EAGLE PARK S/D BLOCK 2, LOT 11
Per'mii::DSPlll142'
PIDf~:O50-78-E~;::'5
(D 0 CO_ MT -
~ T/CO ~
<~ ~ LOT 12
BLK 2 ~
~T
T~ ~t~' O0
~W M O0
Ex, Sunset ~~ ~ ~ ~
Z 0 ~ Plostic Tonk~ ~/~CO ~ ,
g;M'li NS9'32'30"E
~ 82,21'
PTARMIGAN BLVD _ / - SCALE: 1' = 50'
~&-C=4~,~~ ~
~ FINAL GRADE
~B-~=77,7~
~ FILT~ FA~IC
3 ~EXIST,
~ SEWER RDCK ~.~,
~ ~0~ ~~N ~TBP B TANK SCALE, NTg
,'5 ~~' ,,¢'.. T"~'·. :I~0~,.. ';~,, PREPARED FOR:206,3KELL Y DONOVANpTARM/CAN BLVD.
Z FIELD BOOKS c0.Pu~o:
' ......
~ ~ A~UILT: SLS DAm:
~ D~. R~: GRID: ' '
/ ACAD R~: 11-060 JOB No.: 11-060 · AK. 99577-51
Permit Number: OSP111142
Tax Code Number: 05078225000
Work Type: Septic
Permit Effective Dates: July 14, 2011
Design Engineer:
Subdivision:
On-Site Wastewater Disposal System Permit
MUNICIPALITY OF ANCHORAGE
Development Services Department
On-Site Water & Wastewater Program
4700 Elmore Road, PO Box 196650
Anchorage, AK 99519-6650
Telephone: (907) 343-7904
Upgrade
to July 13, 2012
ARC TERRA CONSULTING INC
EAGLE PARK
Site Legal Address: EAGLE PARK BLK 2 LT 11 G:0056
Owner/Address: DONOVAN KELLY J
20613 PTARMIGAN BLVD EAGLE RIVER AK 995778736
Site Mailing Address:
20613 PTARMIGAN BLVD, Eagle River
Lot Size in Sq Ft: 45041
Total Bedrooms: 3
This permit is for the construction of:
Y Disposal Field Y SepticTank N Holding Tank N Privy N Private Well N Water Storage
All construction must be in accordance with: 1. The attached approved design.
2. All requirements specified in Anchorage Municipal code Chapters 15.55 and 15.65 and the State of Alaska Wastewater
Disposal Regulations (18AAC72) and Drinking Water Regulations (18AAC80).
3. The wastewater code requires inspections during the installation. The engineer must notify the Development Services
Department at least 2 hours prior to each inspection. Provide notification by calling (907) 343-7904 (24 hours).
4. From October 15 to April 15, a subsurface soil absorption system under construction during freezing weather must either:
A. Open and Close on the same day.
B. Covered, sealed, and heated to prevent freezing.
Date: '~//~¢~'f/.
Municipality of Anchorage
Development Services Department
Building Safety Division
On-Site Water and Wastewater Program
4700 Bragaw Street
P.O. Box 196650
Anchorage, Alaska 99519-6650
www.muni.org/onsite
(907) 343-7904
ON-SITE SEWER/VVELL PERMIT APPLICATION
FOR A SINGLE FAMILY DWELLING
Parcel I.D. 050-782-25
Property owner(s) KELLY J. DONOVAN
Mailing address20613 PTARMIGAN BLVD., EAGLE RIVER, AK
Site address 20613 PTARMIGAN BLVD., EAGLE RIVER, AK
Day phone
Zip Code 99577
Zip Code 99577
Legal description (Sub'd., Block & Lot) EAGLE PARK BLOCK 2, LOT 11
Legal description (Township, Range & Section)
Lot Size45041 Sq. Ft. Number of Bedrooms 3
THIS APPLICATION IS FOR ([~ all that apply):
Absorption Field []
Septic Tank []
Holding Tank []
Privy []
Private Well []
Water Storage []
THIS APPLICATION IS AN:
Initial []
Upgrade []
Renewal []
I certify that the above information is correct. I further certify that this application is being made for a
Single Family Dwelling and is in accordance with applicable Municipal Codes.
ARCTERRA
(Signature of property owner or authorized agent)
Permit/Rush Fees: $530.00
Date of Payment: -'J - i- i \
Receipt Number: Id~ ~)~¢/-~
(Rev. 11/05)
o~'(' i'1~ ~q~-
Waiver Fees:
Date of Payment:
Receipt Number:
c TERRA
CONSULTING~ INC
212 E. 51st Ave, Anchorage, AK. 99503
Office (907) 868-3791, Fax (907) 868-3793
JulyS, 2011
Municipality of Anchorage
Development Services Department
On-Site Water & Wastewater Program
P.O. Box 196650
Anchorage, AK 99519-6650
Subject: Upgrade Sewer Permit - Eagle Park Block 2, Lot 11
The owner has requested we proceed forward to obtain a septic permit to
upgrade the failed leachfield on the subject lot. The general slope of this lot is
approximately flat (0-2%) over the septic area.
On June 22, 2011 a testhole was performed to investigate soils and groundwater.
The results of this test are attached for your review. The proposed upgrade will
serve the existing 3-bedroom house. We propose to install one 42' long deep
trench. Groundwater was not encountered during excavation or at monitoring.
The property and adjacent lots are served by private water. There is no surface
water within 100' of the proposed system and there are no known curtain drains
within 50'. We do not expect there to be any adverse effect on adjacent lots by the
development of this system. If you have any questions, please contact me at 868-
3792/FAX 868-3793.
Respectfully submitted,
ArcTerra Consulting, Inc.
Kenneth M. Duf~E.
Attachments:
On-Site Sewer Application
Wastewater Absorption System Details/Site Plan
Soils Log/Percolation Test
Owner/Contractor Specs
20441 PTARMIGAN BLVD · EAGLE RIVER, AK 99577-8736 · PH (907) 868-3791 · FAX (907) 868-3793
F
WELL & WASTEWATER DISPOSAL SYSTEM
DETAILS / SITE PLAN
EAGLE PARK S/D BLOCK 2, LOT 11
GRAPHIC SCALE
0 50 1 O0
~G' UTIUTY Easement
/
/
/
/
I
I
·
I
PTA I
/
DESIGN DETAILS I ~b
4 B~RW x 150~0 ~G~ ,~
600 GPD/~D PER SQ. FT. 0 ~ HIN~N,): 500 SQ. FT
~ (~/(~' X 6(D) (6,0' GRAVEL) : 4~FT, TRENCH
USE ~ TRENCH -~ (L) X B' (~) X 6,0'(?)
depth o~ ~ys~em is I0,0' m~x ~Pom g~de,
To~[T°~[ depth o~r~ve[ be[ow distribution oPigin~(pipe is 6,0 ,
/
NOTES:
~, mSUL~TE T~N~ ~r <4~
Permit
PID# 050-782-25
FLAG ALL WELL RADII,
EASEMENTS & LOT LINES
PRIOR TO CONSTRUCTION
NO PUBUC H,~LLS WITHIN 200' OF
PROPOSED SYSTEM, NO PRIVATE
WET_&S WITHIN 200' OF' PROPOSED
SYSTEM EXCEPT AS NOTED. NO
SEPTIC SYSTEMS WITHIN 200' OF
PROPOSED WELL EXCEPT AS NOTED.
INSULATE TRENCHES WITH 2' HD BURIAL FDAW IF < 3' DF CDVER .(WIN 2' CDVER W/ INSUL)
CONTRACTOR WILL ENSURE ALL OTHER SEPARATIONS TO ADJACENT WELLS, SEPTICS, LOT
LINES, FOUNDATIONS & ALL OTHER SETBACKS.
,~Server~,Storage~WELL & SEPTIC - Filed By Legal
PREPARED FOR:
KELLY DONOVAN
2061J PTARMIGAN BLVD.
EAGLE RIVER, AK 99577
FIELD BOOKS COMPUTED:
BOUNDARY: Johns DRAg~I: kmd
STAKING= Johns C~EC~ED: KMD
AsgUILT: Joh ns
DWG. RI.E:
ACAD RI.E:
11-060
DATE:
REV. D^~:; 6/28/11
C~D: SW056
JOB No.: 11-060
\Egle Park Subd%Block 2%Lot 11X, 11-O60.dwg
PAGE 1 OF 5
· AK. 99577
WATER AND WASTEWATER SYSTEM DETAIL
EAGLE PARK S/D BLOCK 2, LOT 11
GENERAL NOTES'
1. MAINTAINED 10 FOOT
SEPARATION DISTANCE FROM WATER
LINES.
2. MAINTAINED MINIMUM OF 10
FOOT SEPARATION FROM ANY
PROPERTY LINES.
5. VERIFY FOUNDATION CLEANOUT
PLACED WITHIN 5 FEET OF FOUNDATION.
4. CONTRACTOR VERIFIED ALL
SEPARATIONS TO
ADdACENT/SUBdECT WELLS,
SEPTICS, LOT LINES, FOUNDATIONS
AND ALL OTHER REQUIRED .,'~,~, ................... t -,~
5. PLACE A MINIMUM OF/CFEET EEP TRENCH 10 MAX Dt~PTH
OF EARTH COVER (OR EQUIV) OVER
ABSORPTION BED. TWO INCH OF
INSULATION PER SEC. 6.1 MOA ON-SITE
COMPONENT PARTS & MATERIALS
MAY BE SUBSTITUTED FOR ONE
FOOT OF EARTH COVER UP TO A
MAXIMUM OF TWO INCHES OF o',
INSULATION. ;.9
6. MAXIMUM OF 2% GRADE TO o',_
TANK. ~ -"-"--
7. USE :~'-2~" SEWER ROCK
SPECIAL NBTES:
I) N/A
SYSTEM PLAN
SCALE: 1"=50'
~ROPOSED
LOT 1 1 :BROOM
20,005 S.F. \
47.91'
PREPARED FOR:
KELLY DONOVAN
2061.J PTARMIGAN BLVD.
EAGLE RIVER, AK 99577
FIELD BOOKS CO~PUTEO:
eou~o~y: Johns OR^m: kmd
STAKING: Johns C~C~D: KMD
AS'BUILT: John s
DWG. FILE:
11-060
ACAD FILE:
~Server~Storoge~WELL & SEPTIC - Filed By Legol~Egle
DATE:
~EV. OAT£: 6/28/11
~R~D: SW056
Jo~ No.: 11-060
MT
EX. WELL
Pork Subd~Block 2~Lot 11~11-060.dwg
CO-Ex. Sunse~
'lastic Tank
,~RCH
0 30'
GRAPHICS SCALE
SCALE: 1:30
PAGE 2 OF 3
AK. 99571
WASTEWATER SYSTEM DETAIL
EAGLE PARK S/D BLOCK 2, LOT 11
REMOVABLE CAP
CLEANOUT, TYP. EACH LATERAL-~"--~.
MONITORING TUBE.
SURFACE MOUNDED
INSURE DRAINAGE AWAY ~ ~ PERFS BELOW FILL
FROM TRENCH ~ EXIST. GROUND
-[~--- ~.~,k~/.~./~., ,, '/ ~ I'~NAT, VE SO,L BACKFILL
/ .:::~')~//: INSULATED IF LESS
TRENCH SECTION ~ ,;i__
SCALE: NTS ,,, 6 ~. >~ . _IF REQR'D.
ED -F~-~ , ~.~j~ --4-" PERF PIPE (PERFS
SEASONALLY HIGH ~x~,,x~ z
STATIC GROUNDWATER
TABLE /---BED ROCK OR OTHER
1¢/ IMPERMEABLE BARRIER
' to
31VERTER
o o o OF-
~ _ ~ ~? o~ /-BACKFILL MOUNDED
EX 1250 -
·
| TANK I / . ~ ?../ ~ i'.2"3~ ~'~1:~" 6.5 MIN. OF
~ i~ ~ ~ ~['~~ ~ SEWER ROCK
SOLID ABS/PVC PIPE J / I~ ~~~~Dr~
2% TO DRAINFIELD ~1~ '- _ .L
4" PERF PIPE
TRENCH SYSTEM PROFILF ~~O~EDOWN
~~~ SCALE: NTS
~~
. ~ PREPARED FOR:
~ '"~ ~. KELLY DONOVAN
".,..
T 2061~ PTARMIGAN BLVD.
' F~ELD ~OOKS ~u~o= --
B~ND~Y: Johns DRA~: kmd A ~L
DAm '~' '~ ...........
~SS10~V ~ *~U,Lf: Johns ~[v.D,m 6/28/11 'e ~kk
AC~D ~: ~-o6o ~ No.: 11--060 ~' 4~. 99577-~
By gal~Eg Pork xBIock 2~Lot 11~11-060.dwg
J
CONSULTING, INC
212 E. 51 ~t Ave, Anchorage, AK 99503
Office (907) 868-3791, Fax (907) 868-3793
SOILS PERCOLATION TEST
Performed for: Kelly Donovan
Date Performed: 6/22/11
Project:
Depth
(Feet)
10-
11-
12-
13-
15-
17-
18-
Eagle Park B2, Lll
ORG/OL
SP - slight trace of silt / fines
Water percolated/absorbed
rapidly in sandy soils.
B.O.H.
TEST HOLE # TH 11-1
SEE ATTACHED SITE PLAN
FOR HOLE LOCATION
Was Ground water encountered? NO What depth? NA
Depth to water after monitoring? NA Date? 7/1/11
Reading Date Gross Net Depth to Net
Time Time Water Drop
1 6/23/11 1:00 6"
2 1:01 1 min dry 6"
3 * 1:02 6"
4 1:03 1 min dry 6"
5
6
7
8
9
10
11
12
· Water Added
19-
20-
INSITU MATERIAL
SUITABLE AS FILTER
Percolation Rate < 1 (min/in) Perc Hole Diameter 6"
Test Rm~ Between 4 feet and 5 feet
I, Kenneth M. Duffus, certify that this test was performed in accordance with all State
and Municipal guidelines in effect on this date.
AacTEaaA
CONSULTING~ INC
212 E. 51~t Ave, Anchorage, AK. 99503
(907) 868-3791, Fax (907) 868-3793
ON-SITE WASTEWATER DISPOSAL SYSTEM
CONSTRUCTION PRACTICES AND MATERIAL SPECIFICATIONS
LEGAL DESCRIPTION: EAGLE PARK BLOCK 2, LOT 11
GENERAL:
1. The scope of this project includes the installation of a septic tank and/or
drainfield to serve a single-family residence on the referenced property as
delineated on the attached Municipality of Anchorage (MOA) permit and site
plan. Construction shall be in accordance with the approved site plan. and
design drawings; MOA permit with any special provisions or conditions, and all
applicable State and Municipal Wastewater Disposal Regulations.
2. ArcTerra Engineering & Surveying, Inc. (ArcTerra) assumes no responsibility of
the accuracy of the as-built survey provided by the owner or owner's
representative.
3. The owner or contractor is responsible to notify the engineer of any discrepancies
noted on the design plans or drawings prior to commencing work. These
discrepancies could be, but not limited to, possible encroachments, surface water,
varying soils, unplatted easements, types or use of dwellings on or adjacent to
property, nearby public wells, etc.
4. The contractor shall be responsible for locating any necessary underground
utilities, easements, property lines and surface water. The owner and/or
contractor shall ensure, if deemed appropriate, that a registered land surveyor
prior to construction flags all setbacks. The contractor shall be responsible for
verifying all pertinent separation distances and component layout.
5. Unless specifically agreed otherwise, the property owner shall be responsible for
final grading areas subsequently depressed from soil settling. On all leachfield
mound systems, the property owner shall be responsible for ensuring a
satisfactory vegetation growth over the mounded area.
6. The MOA Development Services Department On-Site Water & Wastewater
Program must certify contractors installing wastewater disposal systems.
Owners installing their own systems must also receive prior approval from said
MOA Department.
SEPTIC TANK ! HOLDING TANK / LIFT STATION INSTALLATION:
1. A septic tank is to be constructed by a certified septic tank manufacturer.
Construction shall include two 4" cleanouts for pumping access.
2. The septic tank shall be sufficiently bedded with proper material and compacting
to prevent damaging, settling or shifting of the tank.
3. All standpipes on the septic tank shall extend a minimum of 12 inches above the
final grade.
4. Septic tanks installed with less than 4 foot of cover shall be insulated. The
contractor will ensure that the fill over the tank does not exceed the burial depth
rating.
5. A foundation cleanout shall be installed one to four feet from the building
foundation. In the line between the tank and the leachfield there shall be two
adjacent cleanouts (unless an effluent pumping system exists within the septic
EAGLE PARK B2, Lll
July 5, 2011
Page 2 of 3
tank). These cleanouts shall be located on undisturbed soil not more than 10 feet
from the tank. The second cleanout, in line, shall be to clean toward the septic
tank.
6. Final grading over the septic tank shall be such that a positive slope exists away
from the septic tank.
7. All H.D.P.E. tanks shall have a vertical length of 4-inch perforated drainpipe
besides the tank extending to the bottom of the tank to above grade to monitor
ground water.
8. All tanks shall be anchored when there is not enough adequate soil cover to
resist buoyancy forces in high-groundwater areas.
9. All holding tanks and lift stations shall have an audible and visual alarm inside
the residence.
10. All lift stations shall be wired in compliance with the Uniform Electrical Code
and all MOA guidelines.
11. The contractor shall remove the old tank, or abandon it in compliance with the
Uniform Plumbing Code. The contractor is solely responsible for the
abandonment procedure.
ABSORPTION TRENCH/DRAINFIELD INSTALLATION:
1. Excavate the proposed trench to the dimensions shown on the design. The
bottom of the excavation shall be within 2 inches of level. If the sidewalls of the
excavaction become smeared, they must be raked or scratched (roughed-up)
before gravel (sewer rock) placement.
2. Once the sewer rock is installed, the distribution pipe is installed level with the
perforations facing downward. Gravel is then to be placed over the distribution
pipe to provide a minimum of 2 inches of cover over the pipe.
3. A silt barrier must be installed between the final gravel layer and the native soil
backfill. Ensure the silt barrier covers the entire gravel surface before placing
backfill.
4. Monitoring tubes shall be four- (4) inch diameter, installed approximately in the
locations shown on the design, and extend a minimum of 12 inches above final
grade. The portion of the monitoring tube extending through the gravel shall be
perforated from the bottom of the trench to the invert of the distribution pipe.
This is equivalent to the effective depth of the gravel as noted on the design.
5. Backfill over the final gravel layer must not be less than twenty-four inches.
Insulation must be installed when the backfill depth is less than thirty-six (36)
inches. The finish grade over the trench must be mounded to prevent the
formation of a depression after settling.
6. All advanced technology waste water disposal systems (Advantex, Biocycle,
Intermittent Dosing Sand Filter, etc...) shall be constructed, installed, maintained
and monitored per manufacturer's specifications and MOA requirements.
MINIMUM MATERIAL SPECIFICATIONS:
1. A MOA approved septic tank manufacturer must construct any septic tank
proposed for installation.
2. The following pipe materials are MOA approved for use in septic system
installations:
T~ype of Pipe Perforated Solid
Cast Iron Yes Yes
ASTM D3034 (PVC) Yes Yes
ASTM F810 (HDPE) Yes No
ASTM D2662 (ABS) Yes Yes
20441 PTARMIGAN BLVD · EAGLE RIVER, AK 99577-8736 ° PH (907) 868-3791 · FAX (907) 868-3793
EAGLE PARK B2, Lll
July 5, 2011
Page 3 of 3
3. Insulation shall be at least 2" thick extruded direct burial polystyrene (Dow
Chemical Company Styrofoam HI or equal).
4. Septic tank inlets and outlets shall be fitted with watertight couplings (Caulder,
Fernco, or equal).
5. A permeable nontoxic silt barrier (Typar 3401, Mirafi 140N, or equal) must be
installed between the final leachfield gravel layer and the native soil backfill.
6. All leachfield gravel (sewer rock) shall be 0.5"-2.5" screened gravel with less than
3% passing the #200 sieve. If deemed necessary, a sieve analysis should be
performed.
7. When sand is being used as a filter material, its gradation specification must
conform to current MOA or ADEC requirements.
INSPECTIONS:
Typically there will be three (3) inspections required during the installation of the
wastewater disposal system. These inspections will occur as follows:
1. The first inspection must be conducted after the excavation of ditches, pits,
trenches, or beds and before the installation of any gravel. A septic tank may be
set in place, but may not be backfilled before this inspection.
2. The second inspection must be conducted after the placement of the sewer rock,
distribution lines, standpipes, and cleanouts, but before the placement of the silt
barrier, insulation, or any other backfill.
3.The final inspection is to occur upon final grading of the property.
Often there will be more than these 3 inspections required, especially with the
installation of multiple trenches, sand filters, pressurized distribution systems, etc. The
inspecting engineer is to be contacted at least 24 hours prior to the start of construction.
If necessary, a pre-construction meeting will take place on-site. The inspecting engineer
will not coordinate, direct or control in any way the contractor's activities.
The owner shall contract with the contractor to perform the work outlined in these
specifications and attached plans and in accordance with the attached MOA permit. All
materials, components, and construction practices shall comply with the MOA's and the
State of Alaska's latest ordinances, regulations, or policies regarding wells and septic
systems. The failure of the inspecting engineer to notice a material or construction non-
compliance does not relieve the contractor of his/her responsibility to correct such
deficiency. There will be no contractual arrangement existing between the contractor
and ArcTerra. ArcTerra shall be the owner's representative and will inspect the work as
stated above to document the contractor's activities. Final acceptance of the contractor's
work rests with the owner and the MOA.
ArcTerra shall have no liability to the owner or to others for acts or omissions of the
contractor or any other persons performing work on this project or the failure of the
contractor to carry out the work in accordance with these construction documents.
ArcTerra's inspecting engineer will not be responsible for the construction means,
methods, and techniques, sequence, procedures or the safety precautions incident to this
project.
BY PROCEEDING FORWARD WITH THE INSTALLATION OF THE WATER
AND/OR WASTEWATER SYSTEM (S), THE PROPERTY OWNER, CONTRACTOR,
AND WELL DRILLER ACKNOWLEDGE HAVING READ AND ACCEPTED THESE
SPECIFICATIONS.
20441 PTARMIGAN BLVD · EAGLE RIVER, AK 9957%8736 ° PH (907) 868-3791 · FAX (907) 868-3793
TYPE OF SOIL ABSORBTION SYSTEM IS: TRENCH
MRXIMUM NUMBER OF BEDROOMS = 4
SOIL RRT!NG
THE REQUIRED SIZE OF THE SOIL RBSORPTION SYSTEM IS:
DEPTH= //~ENGTH= ~Z--~RI:IYEL DEPTH= ~6~,
THE LENGTH DIMENSION IS THE LENGTH (I~l FEET) OF~THE TRENCH OR DR8INFIE~D.
~HE DEPTH OF R TRENCH OR PIT IS THE DISTRNCE D~WEEN THE SURFRCE OF THE
GROUND RND THE BOTTOM OF THE E~CRVATION (IN F~). '
THERE IS NO SET WIDTH FOR TRENCHES. ' '.. ~/~/ '
THE GR~VEL DEPTH IS THE MINIHUM DEPTH'OF OR~DETWEEN THE OUTF~LL ~IPE
HND THE BOTTOM OF THE EXC8V8TION (IN FEET). r ' , '
PRCKRGE PLnNT HRY DE ZNSTRLLED RT T~~EE~TI~SUB~ECT TO THE
~FOLLOH[NG CONDITIONS: ~ [ / / - ~ ~ ~-. : ' ,
1. EITHER R CLRS~ I OR 11 NSF ~R~VE~ HRY BE~IN~TRLLED. - ", '
2. R CONT[NUOU~ NR[NTENRNCE ~EN~ ~EQ~D. /IF/R HRINTENRNCE '
RGREEMENT [S NOT ~T CU~IT MOp H~ ~ ~I~D~O ENLREGE THE
RBSOEPTION SY~T~ RN~/O~U MRYI B~/$~T~ P~SECUTION.
B~CKF[LL[NG OF RNY 5y~~INRL I~SPECTI~ND RPPROVRL BY
[DEPRRTHENT WILL BE ~UB~ECT ~0 PROSECUTION.~ :
~IINIMUH DISTANCE BETNEEN R ~ELL RI.ID RNY ON-~ITE 5[~E DlSPOSRL ~Y~TEH ~
~ee FEET FOR R PRIVRTE HELL OR 2~ FEET FOR R PUBLIC WELL
i OTHER REQUIREHENT~ ~RY ~PPLY. 5P[ClFIC~TIONS ~ND CONSTEUCT[ON DI~H$
~RVRIL~BLE TO INSURE 'PROPER INSTRLLRTION. , .' ' '
PERr~ I T EXP I RES DECEMBER ~l~
CERTIF~ THST
I 8M F~MILI~R WITH THE REQUIREMENTS FOR ON-SITE SEWERS 8ND WELLS 8S SeT
~FORTH B~ THE ~NICIP~LIT~ OF 8NCHORSGE.
I'WILL INSTRLL T~ SYSTEM IN RCCORDRNCE WITH THE CODES. '
I UNDERSTRND THRT THE ON-SITE SEWER ~M~TEM MRY REQUIRE ENLRRGEHENT I~ THE
!RESIDENCE~MODELED TO~L~E MORE THRN 4 BEDROOHJ. ' '
~/~
...........
January 3, 1974
Ross Carrington
1105 West 34th Avenue
Anchorage, Alaska 99503
Subject: Lot 11 Block 2 Eagle Park Subdivision
Permit %771008
A permit issued by this department for well and/or sewer
.system has expired.
Permits are issued on a calendar year basis, as stated
on the permit, by authority of Municipal ordinance.
If you have drilled the well, a well lo'should be sent
to this department to docum~he ~tallation date.
If there are any
- further ~, ~lease contact this
office at 264 4720.,~//
Sincerely,
Health and Envi~
Sewer and Water
January 4, 1978
Lee Sullivan
Post Office Box 197
Eagle River, Alaska
99577
Subject: Lot 11 Block 2 Eagle Park Subdivision
Permit 1771002
A permit issued by this department for well and/or sewer
system has expired.
Permits are issued on a calendar year basis, as stated
on the permit, by authority of Municipal ordinance.
If you have drilled the well, a well log should be sent
to this department to document the installation date.
If there are any further questions, please contact this
office at 264-4720.
Sincerely,
Health and Environmental Protection
Sewer and Water Section
; b!U.~iyCIPALI'i"£ OF ~vr,:; '~-"--'
~ . Dap-'r~f Health and Environmenta!~'~qc:ion
SOILS LO~
PERCOr,%TIO:i TEST
2
4
6
14
18
PERNIT ~0.
DEPART~IENT ( HEALTH R~ID ENYIRO~IErITBL ~TECTION
825 'L' STREET, ANCHORAGE, BK. 995~i
264-4720
WELL PERt4 I T
APPLICANT
LOCATION
LEGAL
LEE SULLIVAN.
P-TAR~II GAN
L ii B 2 EAGLE C~ SUB
BOX 197 E R 99577
LOT SIZE
694-2588
18000 SQURRE FEET
MINI~IUI'I DISTANCE BETWEEN B WELL AND ANY ON-SITE SEWAGE DISPOSAL SYSTEPl IS
100 FEET FOR A PRIVATE WELL OR 200 FEET FOR A PUBLIC WELL.
WELL LOGS ARE REQUIRED B~lD ~IUST BE RETUR[IED TO THE DEPBRT~IENT WITHIN ~0 DAYS
OF THE WELL COI'IPLETION.
OTHER REQUIRE~'IENTS MAY APPLY. SPECIFICATIONS AND CONSTRUCTION DIBGRRNS ARE
AVAILABLE TO I[ISURE PROPER INSTALLATION.
F'ERMIT E~<PIRES DECEMBER ~L~ '1977
I CERTIFY THAT
l: I B~ FB~'~ILIBR WITH THE REQUIRE~E[~TS FOR ON-SITE SEWERS AND WELLS RS SET
FORTH BY TH~?IUNI~ C IPRLITY OF RNCHORRGE.
2: I W~LL ~TRLL THE SYSTE,IH ACCORDANCE WITH THE CODES.
~.~/APPLICBNT LEE SULLIYAN
V3. 0
A & L DRILLING COMPANY
BOX97, EAGLE RIVER, ALASKA99577 · TELEPHONE694-2588
OWNER OF LAND
ADDRFSS
LEGALDESCRIPTION A l! ~l,~ ~
DATE-Started t//7'/77 Ended
11/~*/'7~7
· !
PERMIT NUMDER '~"7 lOC' o~
DEPTll OF WELL
STATIC LEVEL OF WATER FT.
DRAW DOWN FT.
GALS. PER HR ~7 ~ O
KIND OF CASING
KIND OF FORMATION:
From (~ FI. to c,~ Ft.
From ~') FI. to !~' Ft.
From !~ Ft. to c~! Ft.
From ~l Ft. to 3t~ Ft.
From ~ Ft. to ~? Ft.
From g~ Ft. to .3~> Ft.
From...,7~.~Ft. to <~ [ Ft.
From fi ! Ft. to ~;~t~' Ft.
From '7(~ Ft. to ~'o~ FI-
From__Ft. to Ft.
From Ft. to Ft,
From Ft. to Ft,
From Ft. to Ft,
From Ft. to Ft
From __.Ft. to Ft..
From Ft. to Ft.
From Ft. to Ft..
From
From
From~
From
From
From
From
From
From
From
From
From.__
From,__
From
FI. to Ft.
FI. to Ft.
__Ft. to Ft..
Ft. to Ft,
Ft. to FI
FI. to Ft.
FI. to Ft.
FI. to__Ft.
Ft. to Ft.
FI. to Ft.
Ft. to__.Ft.
FI. to Ft.
FI. to Ft.
FI. to Ft.
FI. to Ft.
FI, to Ft.
Ft. to FI.
MISCL. INFORMATION:
DRILLER'S NAME ,~, c,,-~
1.-GENER~LINFORMA~ON
~ MuNIcIPaLiTY OF ANCHORAGE~'''~ 0 ~"0/~ ~ ~' ~
CERTIFICATE OF INSPECTION FOR H~LTH AUTHORITY APPROVAL )]~.~ [
OF ON-SITE SEWER AND WATER FAClLI~
2~720
. :- Application Date ~'.
(a)-/Legal Description (include Io~ block, subdivision. ~ction, township, range) ...... - "'~ .'/'f:
koeation [addm~ or dire~ion~} ~. ...-
'" i. - '" ' ': ...... L' T~3~'-~- Telephone: Home" 694-3007 .... - = Business- 26
..:'- :::,: (b)" Apphcant Na,me PATR]:CF~/~ 5:-84 7 .....
'i '' .-.. Applicant Address' 206i3 Ptm - an Blvd..'. EAGT..,S PA'VgA;' AZASKA 99577 ,--".
.-<- - .: ' '(~): Al~'pli~:~n~is iche~k on'i: I:endi~g In~titutio~ r-I ;'owr~e~./b~ji!dei~].i B~y?r.E]i o!h~r. ~]. {e.xpl;!p)
':' .... . : : · ;.?: ' - ~ ' "-~-"="'"='<",' "'?'"'" '-?.' ':. : '._ ' ', '_ ' ,." .'.': :
- ' ' "' -" Telephone. .
(d) L~nding Institution ]~]:P,.S~ ]qA'[~/:O~AL A~CHORAG~'' "' :' ' !~' 265-3h06; '' ' --'~"'"" ~:'''':''''
· -" Address"" - ..... P.O. BOX, 1OO720". '. ANC~ORAC~;"A~'~'ggsIO' .... ,... ,._,,~ .....~:--'_,.,=
(e) ' Real Estate Company and Agent N/A ~ ' "' ; ' '"' ' ' "' :' ' :'
Address N/A
Telephone N/A ' '
(f)
Mail the HAA to the following address: -'.[ .... - -.' ... -.
I
TYPE OF RESIDENCE
Single-Family ~] Multi-Family 1'3
N~rnber of Bedrooms /4
Other
WATER SUPPLY
Individual Well I~1 Community I'3 Public r3
Note: If community well system, must have written confirmation from the State Department of Environmental Conservation
attesting to the legality and status.
4. SEWAGE DISPOSAL
Onsite ~ Public I-I Community I-I Holding Tank I-I
Note:' If community well system, must have written confirmation from the State Department of Environmental Conservation
attesting to the legality and status.
Page 1 of 2 72-025 (11/84)
5. I~NGINEERING FIRM PROVIDING INSPECTIONS, TESTS, FILE SEARCH, DATA AND INFORMATION ·
AS certified by my seal affixed hereto and as of the validation date shown below, I verify that my investigation of this Health
--, Authority Approval shows that the on-site water supply and/el; wastewater disposal system is safe, functional and adequate
. for the number of bedrooms and type of structure indicated herein. I further verify that based on the information obtained
from the Municipality of Anchorage files and from my investigation and inspection, the on-site water supply and/or
..... wastewater disposal system is in compliance with all Municipal and State codes, ordinances, and regulations in effect on
the date of this inspection.
Name of Firm FACa',R P.~V'RR F'N'G~ S"E3~V'T~ Telephone c)o7/6qt4-519~
- ':':~d~r~ss "' P_O_ P~Y 77'~q/1 ~F.~t'~,'~. ~v~ A~ 99577
Dire!' ) nbe. a. Iqoq' -
o.~,un=r~rrn~ .. ~ ~ · ~ , -- -.-- ........... '--..'~.;',,::,..'...' .,'
Approved D~sapproved Cond ~ona
':-;?:Terms of Conditional Approval.
".TTh~ Muncipality of Anchorage Depa~ment of Health and Environmental Protection (DHEP) issu~'Health Authori~ ..,:. .-:.
Approval ce~ificates based selby upon the representations' given in ~rag;aph 5 above by ~h independeht pr~fe~'ona Y -~.';.-~:
engineer registered in the State of Alask~ The DHEP does this as a cou~esy to purchasem of homes and their rending '" '
institutions in order to satis~ ce~ain federal and state requirements. Employees of DHEP do not conduct inspections or
analyze data before a ce~ificate is issued. The Municipali~ of Anchorage is not responsible for errom or omissions in the
professional engineer's work.
Page 2 of 2
RECEIVED
WELL DATA
MUNIClPALiT~ OF ANCHORAGE (MOA)
HEALTH AUTHORITY APPROVAL (HAA)
CHECKLIST - FEBRUARY 1984
264,-4720
Legal Description: ~-~'
Well Classification ~,,',' t' ~
Well Log Present (Y/N)
Total Depth ~'~. · Cased to ~'/-~ 7'" Depth of Grouting
StaticWaterLavel Ka· ,~/...,.. ~"~,,e ~.~ ~'",~'.,~$ PumpSetAt
Casing Height Above Ground /~ '· Sanitary Seal on Casing (Y/N)
Y Depression Around Wellhead (Y/N)
Electrical Wiring in Conduit (Y/N)
Separation Distances from Well:
To Septic/Holding Tank on Lot
If A. B, C, D.F-C. Approved (Y/N)
Date Completed ///5'-,/ 7 ? Yield
Y
To Nearest Edge of Absorption Field on Lot
To Nearest Public Sewer Line
Cleanout/Manhole
Water Sample Collected by ~",'"2
Water Sample Test Results
; On Adjoining Lots ~7/,~ '
/,2~ · ; On Adjoining Lots '~'/~" '
To Nearest Public Sewer
To Nearest Sewer Service Line on Lot /~' /
; Date /~../~,.q,,/,P 2'
Comments
B. SEPTIC/HOLDINGTANK DATA
Date Installed ,/? 7 '~ Size /~ 5'0 v~/. No. of Compartments
Standpipes (Y/N) ~V Air-tight Caps (Y/N) ,v Foundation Cleanout (Y/N)
Depression over Tank (Y/N) A/ Date Last Pumped ~'&'/~'
Pumping/Maintenance Contract on File (Y/N) ~'/~ ; for
Holding Tank High-Water Alarm (Y/N) ,,~',,/,e Temporary Holding Tank Permit (Y/N)
Separation Distances from Septic/Holding Tank:
To Water-Supply Well /~' ~' '
To Property Line .5- ~ ·
To Water Main/Service Line .~e ~ Course
To Building Foundation ~ '
To Disposal Field 4//
To Stream, Pond. Lake. or Major Drainage
Comments
Page 1 of 2
72-026(11/84)
C. ABSORP~ON ~ELD DATA
Soils Rating in Absorption Strata
Date Installed , /'~' 7~'
Width of Field ~ ·
Square Feet of Absorption Area ~'~
Depression over Field (Y/N)
Results of Lest Adequacy Test ,...~'~, X'~'; ~'~
Separation Distance from Absorption Field:
TO Water-Supply Well /43 ~ ·
To Building Foundation /-~"
Lot
TO Water Main/Sen/ice Line '~/~' ¢
To Stream/Pond/Lake/or Major Drainage Course
To Driveway. Parking Area, or Vehicle Storage Area
Comments
Type of System Design
Length of Field --~"~ ·
Depth of Field ~'~ ·
Gravel Bed Thickness, ~ /
Standpipes Present (Y/N) )/
Date of Last Adequacy Test /~/·
To Property Line 3'?. 5,-
To Existing or Abandoned System on
; On Adjoining Lots .v. 3~ ·
To Cutbank (if present) ~'
D. LIFT STATION
Date Installed
Size in Gallons
"Pump On" Level at
High Water Alarm Level at
Tested for
Electrical Codes (Y/N)
Dimensions
Manhole/Access (Y/N)
"Pump Off" Level at
Vent (Y/N)
Pumping Cycles during Adequacy Test. Meets MOA
Comments
'* Check Permitted Bedroom Rating Against HAA Request **
I certify that I have checked, verified, or conformed to all MOA and HAA guidelines in effect on the date of this inspection.
Signed ~"'~--~ Date /~/~'"///2
Company ~"'.,,~.~'..t: MOA No. 5'z'- ~.~' ~
Receipt No.
Date of Payment
Amount: $
Page 2 of 2
MUNICIPALITY OF ANCHORAGE,
DEPARTMENT OF HEALTH & ENVIRONMENTAL PROTECTION
82~ L Stilt. Ancd~m~e, A!~'~'~ $9501
ENVIRONMENTAL ENGINEERING DIVISION
REQUEST FOR APPROVAL OF INDIVIDUAl. WATER AND SEWER FACILITIES
DISSECTIONS: Co.I. il; o~ ~;~ 1. l.~om;ll.; will .es I. l~X~ld. I~.. allow t~n (10) d~'s for proc~.lng.
MAILING ADDRESS
4. REALTOR/AGENT
r MAILING ADDRE~
PHONE
PHONE
II~ LEGAL OE~CRIIr/TION ~ __ ~ ~,~.
& TYPEOF ~EIDBCE ~ NUMBER OF BEDROO~
~ Four
~ One
NGLE ~AMILY ~ Two ~ Five
~ MULTIPLE ~AMILY ~ ~ree ~ Six
r-~ Other
7. WATE~iViOUAL"
[] COMMUNITY
[] PUBLIC UTILITY
SEWAGE OI$1~SAL SYSTEM
[~INDIVIDUAL/ON-SITE'*
[] PUBLIC UTILITY
* ATTACH WELL LOG. A w~ll log is required for all w~lls drilled
since June 1976. For wells drilled prior to that date, give well
depth (attach log if available.}
**If individual/on-site, give installation date'-'"//(,/ .
If system is over two (2) years old an adequacy test is required
by this Department.
NOTE: THE INSPECTION FEE MUST ACCOMPANY EACH REQUEST BEFORE PROCESSING CAN BE INITIATED.
72.010(3/78)
'
DATE RECEIVED
INSPECTION APPOINTMENTS
TIME TIME TIME
INSPECT R INSPECTOR INSPECTOR
1. TYPE OF RESIDENCE NUMBER OF BEOROOI~
~SINGLE FAMILY ~ ONE ~ THREE ~ FIVE ~ OTHER
~ MULTIPLE FAMILY ~ TWO ~OUR ~ SIX
2. WATER SUPPLY PERMIT NUMBER
~NOIVIDUAL DEPTH OF WELL
~ COMMUNITY
DATEDRILLED /2
g PUBLIC UTILITY
co.~,,o, w..~ ~o~.~c~,w~7/~?~
~AGE DISP~AL SYSTEM PERMIT NUMSER
g 7/~
~NDIVIDUAL/ON -SITE DATE INSTALLED
~PUBLIC UTILITY
~tion Verifi~ INSTALLER
~ptic Tank or ~ Holding Tank
Size: /~ If Tank is homemade SOILS RATING
give di~nsions:
TYP~~ MANUFACTURE~
TOTAL A~ORPT~ON AREA MATERIAL
· DISTANCESwELL TO: ~tic/~ldlng/~ I Tsnk i ~orptlon/~Ar~/ J~/~Line~ ~r~t/~L~Line
Absorption Ar~ to n~r~t Lot Line
~ CONDITIONAL APPROVAL (letter must ~m~ny ~rtifi~te)
~ DISAPPROVED
72~110 (Rev. 3/78)
Municipality of Anchorage
Development Services Department
Building Safety Division
On-Site Water and Wastewater Program
4700 Bragaw Street
P.O. Box 196650
Anchorage, AK 99519-6650
www. muni.org/onsite
(907) 343-7904
CERTIFICATE OF ON-SITE SYSTEMS APPROVAL
FOR A SINGLE FAMILY DVVELLING
Parcel I.D. 050-782-25
GENERAL INFORMATION
Complete legal description
Location (site address)
COSA # ~--~
ExPiration Date:
EAGLE PARK BLOCK 2, LOT 11
20613 PTARMIGAN BLVD., EAGLE RIVER, AK 99577
Current Property owner(s) KELLY I. DONOVAN
Mailing address
Lending agency', ,,
Mailing address
Real Estate Agent
Mailing Address
Day phone__
20613 PTARMIGAN BLVD., EAGLE RIVER, AK 99577
Day phone
Day phone
Unless otherwise requested, COSA will be held by DSD for pickup.
NUMBER OF BEDROOMS:
PE OF WATER.SUPPLY:
Iddividual Well
IndividUal :wat~.r StOrage
community class __ Well
Public Water System
3
TYPE OF WASTEWATER DISPOSAL:
[] Individual On-site []
[] Individual Holding Tank E~
[] Community On-site E~
[] Public Sewer [--']
The Municipality of Anchorage Development Services Department (DSD) issues Certificates of On-Site Systems
Approval (COSA) based only upon the representations given in paragraph 4 by an independent professional civil
engineer registered in the State of Alaska. Certificates of On-Site Systems Approval are required for the transfer of
title (except between spouses) for properties served by a single-family on-site wastewater disposal and/or water
supply system. DSD also issues COSAs upon request to homeowners. Certificates of On-Site Systems Approval
are valid for 90 days from the date of issue for properties served by a private or Class C well and may be reissued
with new water sample results. (Certificates may be reissued for a period of up to one year with valid water
samples.) Certificates are valid for one year for properties served by Class A or B wells or a public water system.
The Municipality of Anchorage is not responsible for errors or omissions in the professional engineer's work.
4. STATEMENT OF INSPECTION BY ENGINEER
As certified .by my seal affixed hereto and as of the validation date shown below, I verify that my investigation,
based on procedures outlined in the Certificate of On-Site Systems Approval Guidelines for this application,
shows that the on-site water supply and/or wastewater disposal system is (are) safe, functional and adequate
for the number of bedrooms and type of structure indicated herein. I further verify that based on the information
obtained from the Municipality of Anchorage files and from my investigation and inspection, the on-site water
supply and/or wastewater disposal system is(are) in compliance with all applicable Municipal and State codes,
ordinances, and regulations in effect at the time of installation.
Name of Firm ARCTERRA CONSULTING, INC. Phone 868_3792
Address 20441 PTARMIGAN BLVD., EAGLE RIVER, AK 99577
Engineer's Printed Name KENNETH M. DUFFUS Date 07/15/2011
Engineer's Comments: This investigation was completed in compliance with ADEC and MOA regulations. The
assessment of the condition of the well and septic applies only to the conditions as of the day tested. The flow
and absorption rates may change due to subsurface conditions that may not be obserVed from the surface,
changes inland use, local soil characteristics, groundwater levels that may fluctuate dudng the year and the
water usage of the family being served by the system. The operational life of all well and septic systems are
subject to these various and dynamic characteristics and are outside the control of the
evaluator of the well and septic system. Therefore,
ArcTerra can not give any estimate of how long a
system will function satisfactory for current or future
occupants or can ArcTerra guarantee that no unseen
encroachments, deficiencies or discrepancies exist.
DSD SIGNATURE
~/ Approved for
Disapproved.
Conditional approval for
bedrooms.
bedrooms, with the following stipulations:
Attachments:
COSA Checklist
Septic System Advisory
Well Flow Advisory
Nitrate Advisory
X
Arsenic Advisory
Maintenance Agreements
Supplemental Engineer's Report
Other
Original Certificate Date:
Ma~ni~pality of Anchorage
DerWent Sewices Department
Building Safety Division
On-Site Weter & Wastewater Program
4700 BragaW'Street
P.O. Box 196650
Anchorage, AK 995.19-6650
www.muni.org/onsite
(907) 343-7904
CERTIFICATE OF ON-SITE SYSTEMS APPROVAL CHECKLIST
Legal Description: EAGLE. PARK, BLOCK 2, LOT ~1
Parcel ID: 0~782-25
A. WELL DATA
~:~:~A~,[f:A, .B, crC Pr~PWSI. D #. Welt Log
Da~, c0mpleted11~5~9.77 Sanitary seal (Y~ Y_ v~ms properly protected (Y/N) Y
Total depth 82 ff. Cased to 8/.6 ff. Casing height (above ground) 12+ in.
FROM WELL LOG AT INSPECTION
Date of test 11/0$/77 6/13/2011
Static water level 59 ff. 63 ft.
Well production 12 g.p.m. 6.25 g.p.m.
WATER SAMPLE RESULTS:
Coliform NEG coionies/t00rnL Nitrate 5.08 rng/L
Arsenic: ND mg/I Date of sample: y/5/Zl_
Collected by: ArcTerra
B. SEPTIC/HOLDING TANK DATA
Tank Type~dter~ se~! Date ir~-ta~:~d J ? 7~ Tank size 3250 gal.
Number of Com~ _2 Clea~outs (Y/N) Y Foundation clearmut (Y/N) _~ Depression over tank (Y/N) __N
High water alarm (Y/N) N Date of pumping 6/1.3//,1 Pumper JRs Pumping
C. ABSORP'IrtONFIELD DATA
Date installed 07/2~11 S~il rating. (g.p.d./ft~ or ft21bdrm) 1.2 System type Deep T:rench
Length 5'~'~t.~ ~' ~ d' ~. ~rave~ beicw pipe 4,, ~. Tota~depth ~ ~.
Eft. absorption area~; ~,OOft2 Monitoring tube Y Depression over field N_
Date of adequacy test NA-New System Results (Pass/Fail) For _~ bedrooms
Fluid depth in absorption field before test in. Water added gal. New depth '
Elapsed Time: _ min. Final fluid depth __ in. Absorption rate >= g.p.d.
Any rejuvenafiorr~t 12 mo.)(Y/N&'type) ff yes, give date ---
in.
LIFT STATION
Date installed
"Pump on" level at
Datum
Size in gallons
in. "Pump off' level at in.
Cycles tested
E. SEPARATION DISTANCES
Manhole/Access (Y/N).
High water alarm level at. in.
Meets alarm & circuit requirements?
On adjacent lots
On adjacent lots :tOOO+
Public sewer menhole/cleanout
Holding tank
Manure/animal excrete storage areas 10OO+
Absorption field $'+
Surface water :tOO'+
SEPARATION DISTANCES FROM WELL ON LOT TO:
Septic tank/lift station on lot :tOO'+
Absorption field on lot :tOO'+
Public sewermain ?$,+
Sewer/se~ic ~sewice line ' 25,+
Animal containment areas SOO+
SEPARATION DISTANCES FROM SEPTIC/HOLDING TANK ON LOT TO:
Building foundation 5'+ Property line 5'+
Water main :tO°+ Water service line :tO'+
Wells on adjacent lots :tOO'+
SEPARATION DISTANCE FROM ABSORPTION FIELD ON LOT TO:
Property line :too+ Building foundation :tO'+
Water Service line :too+ Surface water 100'+
Curtain drain ,~OO+ (None Known)
COMMENTS
Water main lO'+
Driveway, parking/vehicle storage
Wells on adjacent lots loo'+
:too+
G. ENGINEER'S CERTIFICATION
I certify that I have determined through field inspections and
review of Municipal records that the above systems are in
conformance with MOA COSA guidelines in effect on this date.
Engineer's Printed Name KI~NN~,TH M. DL~S~
Date 7/15/11
COSA Fee $250.00
Date of Payment
Receipt Number
(Rev. 11/05)
Waiver Fee $
Date of Payment
Receipt Number
Municipality of Anchorage
Community Development Department
Development Services Division
On-Site Water and Wastewater Program
4700 Elmore Street
P.O. Box 196650 Anchorage, AK 99519-6650
www.muni.org/onsite
(907) 343-7904
Nitrate Advisory
Certificate of On-Site Systems Approval # 111314
A Certificate of On-Site Systems Approval inspection and test of potable
water was recently conducted on the well water supply on Block 2, Lot 11 of
Eagle Park subdivision. This inspection revealed a nitrate concentration of
5.08 milligrams per liter (mg/L) was reported for the property's well water
sample. The Environmental Protection Agency (EPA) has established a
maximum contaminant level (MCL) of 10.0 mg/L for public drinking water
systems. While private wells are not subject to this regulation, EPA
standards are based on existing health information and can therefore be used
to gauge the relative quality of water from private wells. Please see the
attached "Nitrate Fact Sheet" for important information regarding nitrate.
This advisory must be attached to all copies of the subject Certificate of On-
Site Systems Approval.