ON-SITE WASTEWATER INSPECTION REPORT
Permit Number: OSP191170 PID Number: 050-291-12
Dwelling: ❑ Single Family (SF) ❑ with ADU ❑ Duplex (D) ❑ Two Single Family Project: ❑ New ❑ Upgrade
Name
Rebecca & Randy Pasley
ABSORPTION FIELD
❑ Deep Trench ❑ Wide Trench ❑ Bed ❑ Mound
Site Address
19114 1st St. Eagle River, AK 99577
❑ Other
Phone
Number of Bedrooms
Soil Rating
Total depth from original grade
854-0059
3
Existing GPD/SF
Ft.
LEGAL DESCRIPTION
Depth to pipe invert from original grade
Ft.
Gravel depth beneath pipe
Ft.
Subdivision Block Lot
Eagle Crest #1 Tract B 38
Fill added above original grade
Ft.
Gravel length
Ft.
Township Range Section
Gravel width
Ft.
Beds: Number of Lines
Distance between lines
Ft.
SEPARATION DISTANCES
To
Septic
Absorption
Lift Station
Holding
Sewer
Total absorption area
Number of trenches
Dist. between trenches
From
Tank
Field
Tank
Line
Ft2
Ft.
Well
>100'
N/A
N/A
N/A
>25'
TANK 0 Septic S.T.E.P. ❑ Holding El Other
Manufacturer
Greer
Capacity
1,250 Gal.
Surface Water
>100'
N/A
N/A
N/A
Material
Number of compartments
Lot Line
>5'
N/A
N/A
N/A
NA
Plastic
2
Foundation
>10'
N/A
N/A
NIA
LIFT STATION
Manufacturer
Capacity
Remarks Tank only permit.
Greer
250 Gal.
Alarm location
Basement SE corner
Electrical installed by
Kunder Contracting & Consulting
PIPE MATERIAL House to tank D3034 Tank to
drainfield D3034
Installer
Wilco Contracting
Drainfield CO/MTD3034
Inspector J. Williams
BENCH MARK (Assumed elevation) 100 ft
Inspection1st 9/26/19
Location and description
,a
Bottom of siding.
3rtl 4th
ON-SITE WATER AND WASTEWATER SECTION APPROVAL
Engineer's Stamp
Conditional Approval: Date
��P�°°'°"°°°°�;9r��
ffi f« 49th�
�..aa n.e...sea..gsy..a. .a3..aa.
..`. ...... � «
.aa....e.....I....... eeea acaanae°sa°mes�./ea
�n h{ICHAEL .. ANDERSON .
}'n S No. CE-4381
��Fp'°•.°,
Septic System
C
Approved Date 020
12/18/19°®«.«'�°fir
4i
Note: this approval does not include well permit requirements.
{RCv UD/VL/ 10)
EAGLE CREST #1, TRACT B LOT 38
PERMIT # OSP191170
EXISTING WELL
A B
2CO 36.2 45.8
MH1
37.8
47.4
MI -12
41.0
51.0
MT
40.4
52.8
GE
ENGINEERING
NEW 1,250 GAL
STEP T
PID # 050-291-12
1st STREET
LOT 38
DECOMMISSIONED EXISTING /
IN PLACE PER MOA TRENCH.
CODE.
-----------------------------------------------------
10' UTILITY EASEMENT
to] M,fl
PLAN AS -BUILT
0 20 40
FEET
1"=20'
LOT 37
LOT 48
LEGEND
CO - CLEANOUT
2CO - DOUBLE CLEANOUT
FCO - FOUNDATION CLEANOUT
FS - FLOW SPLITTER VALVE
MH - MANHOLE
MT - MONITORING TUBE
SV - SEPTIC VENT
TH - TEST HOLE
EAGLE CREST #1, TRACT B LOT 38
PERMIT # OSP191170
PID # 050-291-12
U! .YJ
PROFILE AS -BUILT
(NO SCALE)
a
0
M
FIRST STREET\
CHAIN-LINK FENCE
—
z
C,
Lot 39 0
� q
A Pis
L
Lot 38
17,820 S.F.
\ \OODEN FENCE -
Lot 46
I
I
89.58'00"E 132.00'
I �
RETAINING WALL
I �
e
PORCH I
48.3' /
1 STORY RESIDENCE
w/ DAYLIGHT BSMT.
o �
20.0' 16.0'
0 0 12.3'
DECK m 12.3' ai
6A'04.0' /
---FMTMjjll DECK
IL8.2'.12.2' SHED
w/ RAMP
Lot 47
DECK
Lot 37
10' UTILITY
EASEMENTS
I
Lot 48
I
I
I
PLOT PLAN —__ AS BUILT _X_ SCALE _1._= 30__ GRID _ NW 0054Project No.
11500 Daryl Avenue, Anchorage, Alaska 99515-3049
Lang & Associates, inc. (907) 522-6476 Phone 9000pppp
(907) 522-4625 Fax oo
Professional Land Surveyors kenOlangsurvey.com o �F.q,�901p��
jonothanOlangsurvey.com O� .• l)
I hereby certify that I have surveyed the following described property: Q P DO
LOT 38, TRACT B, EAGLE CREST #1 (PLAT No. 63-70) Q; 49TH*0�
Anchorage Recording District, Alaska, and that the Improvements situated thereon are •' • • "" • • • •' KE • • • •'�
within the property lines and do not encroach onto the property adjacent thereto, that
no improvements on the property lying adjacent thereto encroach on the surveyed 0'p ; ... G
premises and that there are no roadways, transmission lines or other visible �O �c o�
easements on said property except as indicated hereon.
a ..
202
Dated this the — SPF ' .LS -5.. yJQQ
_'��___ Day of --_TN-+uec�- , Lova of Anchorage, Alaska �Q OQ •"••�..�Oo
404R0FfSSIONAL c�
It is the responsibility of the owner to determine the existence of any easements, OpOOoo��
covenants, or restrictions which do not appear on the recorded subdivision plat. AECC963
MUNICIPALITY OF ANCHORAGE
On -Site Water & Wastewater Program
PO Box 196650 4700 Elmore Road
Anchorage, Alaska 99519-6650 Phone: (907) 343-7904 Fax: (907) 343-7997
http://www.muni.org/onsite
On -Site Wastewater Disposal System Permit
Permit Number: OSP191170
Work Type: SepticTank Upgrade
Tax Code Number: 05029112000
Site Legal Address: EAGLE CREST #1 TR B LT 38 G:0054
Site Mailing Address: 19114 FIRST ST, Eagle River
Owner: PASLEY REBECCA C
Design Engineer: FORGE ENGINEERING
This permit is for the construction of:
Effective Date
Expiration Date:
Lot Size in Sq Ft
Total Bedrooms:
y.S'
�3
I)C'1)11'CIl7C►1C
5/16/2019
5/15/2020
17820
❑ Disposal Field 0 Septic Tank ❑ Holding Tank ❑ Privy ❑ Private Well ❑ Water Storage
All construction shall be in accordance with:
1. The attached approved design.
2. All requirements specified in Anchorage Municipal code Chapters 15.55 and 15.65 and the State of Alaska
Wastewater Disposal Regulations (18AAC72) and Drinking Water Regulations (18AAC80)
3. The wastewater code requires inspections during the installation. The engineer shall notify the Development
Services Department per AMC 15.65. Provide notification by calling (907) 343-7904 (24/7).
4. From October 15 to April 15, a subsurface soil absorption system under construction during freezing weather
shall be either:
a. Opened and Closed on the same day, or
b. Covered, sealed, and heated to prevent freezing
If" V1111,1411",
Date:
-.A 0 M W__ Al �"
WN —
WF Date:
3
MUNICIPALITY OF ANCHORAGE
Community Development Department Phone: 907-343-7904
Development Services Division Fax: 907-343-7997
On -Site Water & Wastewater Program
ON-SITE SEWER/WELL PERMIT APPLICATION
Parcel I.D. 050-291-12
Property owner(s) Rebecca Pasley
Mailing address 19114 1st Street Eagle River, AK 99577
Site address Same
Day phone
Legal description (Sub'd., Block & Lot) Eagle Crest #1, Tract B, Lot 38
Legal description (Township, Range & Section)
Lot Size 17,820 Sq. Ft. Number of Bedrooms Three (3)
APPLICATION IS FOR:
APPLICATION IS AN:
TYPE OF DWELLING:
(® all that apply)
Absorption Field
❑
Initial ❑
Single Family (SF)
❑X
(w/wo ADU)
Septic Tank
NUpgrade
RDuplex
(D)
❑
Holding Tank
❑
Renewal ❑
Multiple Dwellings
❑
Privy
❑
(SF and/or D)
Private Well
❑
Water Storage
❑
THIS APPLICATION INCLUDES A VARIANCE / WAIVER REQUEST FOR:
Distance:
I certify that the above information is correct. I further certify that this is in accordance with
applicable Municipal Codes.
(Signature of property owner or authorized agent)
Permit/Rush Fees: ;U6
110
Date of Payment: .2 16 1-7
Receipt Number: /� ®g1d(PI)
Permit No. 6.S101g6r-'70
Permit App_:- ::'__C
Waiver Fees:
Date of Payment:
Receipt Number:
Waiver No.
PO BOX 240773
ANCHORAGE, AK 99524
522-7773 677-7766 (FAX)
May 6, 2019
MOA Development Services Dept, On-Site Water & Wastewater Program
4700 Elmore Rd
Anchorage, AK 99507
Subject: Eagle Crest #1, Tract B, Lot 38 – 19114 First Street
Septic System Design
Dear On-Site Services Engineer:
The 1,250 Gallon S.T.E.P. on the subject lot has failed and must be replaced. We are submitting
this permit application for the construction of S.T.E.P. Tank to serve the three-bedroom home on
the lot. The attached site plan identifies the location of the home and the existing well and septic
system along with the proposed S.T.E.P. Tank. No conflicts exist between this proposed tank
location and any other well or septic system on this lot or adjacent lots.
Wells on this and adjacent lots are shown. The new tank location will be a minimum of 100’ from
all wells and surface water, and more than 10’ from the house foundation and 5’ from any stair or
deck supports.
Please refer to the attached plan sheet for the septic design. If this design is followed, there will be
no adverse impacts to adjacent properties.
Sincerely,
Michael E. Anderson, PE
5/6/19
Municipality of Anchorage
On-site Water and Wastewater
REVIEWED FOR CODE COMPLIANCE
OSP191170, Rebecca Carroll, 05/16/19
4020 0
FEET
1"=20'
NOTE:
NO SLOPES >25% WITHIN 50' OR SURFACE WATER WITHIN 100' OF THE
PROPOSED SEPTIC SYSTEM
ALL WELLS ON SURROUNDING LOTS WITH IMPACTS TO THIS
PROPERTY ARE SHOWN. NO CONFLICTS WITH WELLS OR SEPTIC
SYSTEMS.
CO - CLEANOUT
2CO - DOUBLE CLEANOUT
FCO - FOUNDATION CLEANOUT
FS - FLOW SPLITTER VALVE
MH - MANHOLE
MT - MONITORING TUBE
SV - SEPTIC VENT
TH - TEST HOLE
LEGEND
MH
EAGLE CREST #1, TRACT B LOT 38
5/15/19
SHED
ASPHALT
ASPHALT1st STREET
10' UTILITY EASEMENT
SHED
3 BEDROOM HOME
EXISTING 1,250
GALLON STEP TANK
DECOMMISSION
PER MOA CODE.
NEW 1,250 GALLON STEP
TANK w/20" MANWAY RISER
TO FIRST COMPARTMENT.
CONNECT TO EXISTING
SERVICE LINES.
EXISTING ABSORPTION
TRENCH TO REMAIN IN
SERVICE.
SV
MH
Municipality of Anchorage
On-site Water and Wastewater
REVIEWED FOR CODE COMPLIANCE
OSP191170, Rebecca Carroll, 05/16/19
0
LOT 39
O
O
L6
M
LO
NT
80
O
O
O
Z
LOT 46
1 st STREET
— t —
N89°58'00"W 132.00
Well ' t ',;; Yard light
Asphalt : Wood ret.
wall
..n
deck
49.
48.0
'a O
N 1 1/2 Story Frame
;. House
a.
12.0
oa
m
N U)
20.0 0 0 16.0 O
.6 deck O
lain link fence deck
LOT 38
Yard light
she 8.0
0
N
--------------
10' Utility Easement
N89058'00"W 132.00
LOT 47
EASEMENTS OF RECORD, OTHER THAN
THOSE SHOWN ON THE RECORDED
PLAT ARE NOT SHOWN HEREON. Fb 10-7, pg 71-72
BLS
LC)
0 Septic vent T_
;O
LO
Septic vents 00
O
Septic tank 0
Septic vent Z
O
M
LOT 37
LOT 48
8355M
SCALE: V= 30'
AS -BUILT NO CORNERS SET THIS DATE
I hereby certify that I have performed a Mortgagee's inspection
of the following described property: LOT 38, TRACT B,
EAGLE CREST SUBDIVISION, FIRST ADDITION
Anchorage Recording Precinct, Alaska, and that the
improvements situated thereon are within the property lines
and do not overlap or encroach on the property lying
adjacent thereto, that no improvements on the property lying
adjacent thereto encroach on the premises in question and
that there are no roadways, transmission lines or other
visible easements on said property except as indicated
hereon.
Dated at Anchorage, Alaska
this 12th day of November 2010
FRED
FRED WALATKA & ASSOCIATES
BE(907-248-1666) Engineers and Surveyors
Municipality of Anchorage Page of_
· ' DEPARTMENT OF HEALTH AND HUMAN SERVICES
ENVIRONMENTAL SERVICES DIVISION
P.O, Box 196650 · Anchorage, Alaska 99519-6650 · Telephone: 343-4744
On-Site Wastewater Disposal System and/or Well Inspection Report
Permit Number: .~t4J C]~'~.~/~)/~ PID Number: ~,.5-~ o ~/-/~
"'~:~. ~ ~/~ Wastewater System: D New ~ Upgrade
~r'~yZ~ /~~ ~,/~ /W ABSORPTION FIELD
P.one: ~/~)~ ~/~ J No. of~d~ms~ = Deep Trench ~Shal[owTrench =B~ =Mound ~Other
LEGAL DESCRIPTION ~""=""=: Z~ GPo~q Fl, Total~pthfromoHglnalg~,
Su~ivbion: j ~th ~ p~ ~flom Ir0m ~i~l gr~e: Gravel depth ~neatb pi~ ~, ~ Ft
WELL: D New D Upgrade Gm~lwidth: ~ Ft / ~ Ft
Yield:GPM IPump ~t at: ~ ~Ft.~' *~ o~... TANK
SEPARATION DISTANCES = Septic a Holding ~S.T.E.P.
From Tank F~d Slal~ Tank ~ Li~ ~ ~ ~ '
Su,=ce LIFT STATION
Lot i t Size in gallons' Manufacturec
, .A SENCH MARK
I AS-BUILT SITE
1l, WASTEWATER DISPOSAL SYSTEM
I LOT 38, TRACK B, EAGLE CREST SUBDIVISION
P.I.D. 050-291-12
i FIRST STREET
;" B ~1 B-~- ~e.r
i ~ FINISHED O~ADE
~' INSULAT[DN ~ SEWER ROCK
~' Bflll~ ~F D~&I~FI[~D 4.0' F~ ~IGI~
~ BOTTOM OF TEST
HOLE
NBTES~
2, HBLE SIZE :
~ 5. TBTAL NUMBER DF HBLES : 38
.¢ ~ 5. HOLES ORIENTED UP W/COVERS EXCEPT BEGINNING & END HOLES.
~~~ 6. ABANDONED EXISTING TANK IN PLACE.
7. INSTALLED NEV 1250 LIFT STAT]ON.
BRAD LORENZEN EAGLE RIVER, AK, 99577
~ss~o~ ~ 8720 ~VANNBE STREET (907)696-61Il/FAX(907)696-8111
~~ INDIANAPOLIS, IN I
DING BAT ELECTItlC
P.O. BOX 446 EAGLERIVEI~ AK. 99577
6/Z7/96
DING BAT .ELECTRIC supplied power ~o the sewage lif~ pump control box and made
all the electrical connection. Electrical work performed to M.O.A.,NEC and State
codes.Work was performed at LOT 38 TRACK B 19114 First St. Eagleriver A.K.
Al(. UC.103573
-!-
MUNICIPALITY OF ANCHORAGE
DEPARTMENT OF HEALTH AND HUMAN SERVICES
P.O. BOX 196650, 825 "L" STREET, ROOM 502
ANCHORAGE, ALASKA 99519-6650
ON-SiTE WASTEWATER DISPOSAL SYSTEM (UPGRADE)
PERMIT
PERMIT NUMBER:SW950406
DESIGN ENGINEER:KND ENGINEERING
OWNER NAME:LORENZEN BRADLEY S & LISA A
OWNER ADDRESS:
DATE ISSUED:12/27/95
EXPIRATION DATE:12/27/96
PARCEL ID:05029112
LEGAL DESCRIPTION:
'EAGLE CREST TR BLT 38
LOT SIZE: 17820 (SQ. FT.)
NUMBER OF BEDROOMS: 3 THIS PERMIT: 3
THIS PERMIT IS FOR THE CONSTRUCTION OF:
DISPOSAL FIELD /SEPTIC TANK SYSTEM
ALL CONSTRUCTION MUST BE IN ACCORDANCE WITH:
1. THE ATTACHED APPROVED DESIGN.
2. ALL REQUIREMENTS SPECIFIED IN ANCHORAGE MUNICIPAL CODE CHAPTERS
15.55 AND 15.65 AND THE STATE OF ALASKA WASTEWATER DISPOSAL
REGULATIONS (18AAC72) AND DRINKING WATER REGULATIONS (18AAC80).
3. THE ENGINEER MUST NOTIFY DHHS AT LEAST 2 HOURS
PRIOR TO EACH INSPECTION. PROVIDE NOTIFICATION BY
CALLING 343-4744 ( 24 HOURS ) (NOT REQUIRED FOR WELL ONLY PERMIT)
4. FROM OCTOBER 15 TO APRIL 15 A SUBSURFACE SOIL
ABSORPTION SYSTEM UNDER CONSTRUCTION DURING FREEZING
WEATHER MUST BE EITHER:
A. OPENED AND CLOSED ON THE SAME DAY
B. COVERED, SEALED AND HEATED TO PREVENT FREEZING
5. THE FOLLOWING SPECIAL PROVISIONS.
[SPECIAL PROVISIONS:
1.) DP. AINFIELD DEPTH MUST NOT EXCEED 4 FT, BELOW
ORIGINAL GRADE.
2.) INCLUDE HOLE SIZE, HOLE SPACING, AND ORIENTATATION
OF DISTRIBUTION PIPE WITH RESPECT TO EACH END OF
TRENCH WITH ASBUILT/INSPECTION REPORT.
3 .) A 2 INCH DIAMETER LATEKAL DISTRIBUTION PIPE IS
ISSUED BY:
SITE PLAN
WASTEWATER DISPOSAL SYSTEM
LBT 38, TRACK B, EAGLE CREST SUBDIVISIDN
P.I.D. 050-2~1-12
FIRST STREET
?
VACANT VACANT
RECEIVED
DEC 2 6 1995
Mumc:pality of Anchorage
Oept. Health & Human Services
PREPARED FOR~
BRAD LORENZEN
8720 IVANHOE STREET
INDIANAPDLIS, IN
(317)897-6818
KND ENGINEERING
20441 PTARHIGAN BLVD
EAGLE RIVER, AK, 99577
(907)696-6111/F^X(907)696-8111
DESIGN DETAILS
WASTEWATER DISPOSAL SYSTEM
LnT 3@, TRACT B, EAGLE CREST SUBDIVISII]N
P.I.D. 050-291-12
CONNECT TO 4' SOLID PROM EXISTING TANK
I ~ BOTTOM OF DRAINFIELD 4.0 FROM ORIGINAL GRADE
STAT[~I~ 48'+
1. RESIDUAL HEA~ = 5'
~. H~LE ~IZE = 3/16' = 1.~0 OAL. PER HOLE ~ 30 P~I
3. 30 GALS {PU~P ~[~IVERY)/X.OO OALS./HOL[ = 30
4. 48 LF LATERAL/30 HOL~ = 1.51' ~PACING PER HOLE
5. ALL HOL[~ ~HALL HAVE CAPS INSTALLED PER MANUFACTURERS
6. PUMP U~[~ IN LIFT ~TATION - ~0 O~I 05 HHF-5
I
BOTTOM OF TEST HOLE 11.0'
WATER OBSERVED 9,5'
500 GAL
DESIGN
CRITERIA
1. 3 BEDROOMS X 150 GAL./DAY/DEDROOH = 450 GPO
2. SOILS RATING~ 1.2 NIN./INCH = 1.2 GPD/SF(?RENCH)
3. 450 GPO/L2 GPO PER SF = 375 SF
4. 375 SF /5' V × 0.64 = 48' L (USE 1TRENCHS 48 L)
5. NINIMUM DESIGN SIZE = 48' L x 5' V x 2.5' D Trench
6. 2° ND INSULATION REQUIRED OVER FIELD <3' OF COVER
7. CONTRACTOR TO PUMP TANK AS NEEDED.
8. CONTRACTOR TO VERIFY YELL SEPARATION DISTANCES TD
SYSTEM PRIOR TD INSTALLATION FROM ALL ADJAC£NT VELLS.
9. ANY ASPHALT, CONCRETE OR APPERTANENC[S DAMAGED DR
10.
Ih
H
DESTROYED BY THE CONTRACTOR DURING CONSTRUCTION SHALL DE
REPLACED DY THE CONTRACTOR AT ND ADDITIONAL COST TO THE DVNER.
CONTRACTOR TD VERIFY AND INSURE 2Z GRADE FROM EXISTING TANK.
CONTRACTOR TD EXCAVATE TANK IN ORDER TO VERIFY INTEGRITY.
PREPARED FOR:
BRAD LORENZEN
8720 IVANHOE STREET
INDIANAPOLIS, IN
(317)897-6818
KND ENGINEERING
20441 PTARMIGAN BLVD
EAGLE RIVER, AK, 99577
(907)696-6111/FAX(907)696-8111
December 5, 1995
Munidpality of Anchorage
Dept. of Health & Human Services
On-Site Services Section
P. O. Box 196650
Anchorage, Alaska 99519-6650
ATTN: James Cross, P.E.
RECEIVED
DEC 8"
19;~5
D~,iu,?:.c;pa!i;y o! Anchorage
epl. Health & Human Services
Subject: Lot 38, Tract B, Eagle Crest S/D - Sewer Upgrade
DearMr. Cross:
On December 1, the sewer upgrade permit application for the subject lot was
returned to me with a list of 11 items for correction. A copy of the cover sheet is
attached for your reference.
I take exception to a number of the deficiences listed by the reviewer. Those are as
follows:
1. Inadequate site plan:
Our submittal does comply with regulations. The lots to the south and
southeast are vacant, while the lot to the southwest is developed. This developed
lot's well is greater than 100 feet from our proposed upgrade and will not impact the
installation. Since the other lots were vacant land, I have shown nothing on them.
2. Labels missing:
Our site plan is drawn to scale as required in code, and as such all radii shown
are also to scale. There is no requirement for additional identification; there is
actually no requirement for well radii at all, but they have been shown for
convenience sake.
The request for labeling on the proposed trench, tank, etc., is answered on
page S2 of my submittal. Although it may be the practice of some firms to place all
information on one sheet, I have found that by providing 2 sheets I can more dearly
show the proposed system both for the reviewer and for the contractor.
.. Subjec~ Lot 38, Track B, Eagle Crest Subdiv~s|on - Sewer Upgrade
DecemberS, 1995
Page2of3
3. Inspection of old septic tank:
My submittal letter clearly states that the existing septic tank is fiberglass. As
you are probably aware, the old Sunset Plastics septic tanks were manufactured
using questionable loading calculations, and hence any breach to their integrity
caused a collapse of the tank. That is to say, either the tank is whole and intact, or is
not. H it is not, we will naturally replace it at 100 feet from the well.
4. Well to tank distance:
It is apparent that the original waiver request was based on a measurement
made from the deanout to the well, since no excavation was attempted. Since there
is no information on file as to the exact size of this fiberglass tank, I used the
dimensions of a 1250 steel tank to approximate the location of the tank with the
deanout pipe located in the center. The cleanout pipe is exactly located by a licenced
surveyor. Based on the above and research to date there is no method in which to
assert that the separation distance is less than 95 feet short of excavating the tank.
For the sake of clarity, I have sketched in a possible tank location.
Information on pump size, description, and hole spacing, absorption field
location:
This is a standard application lift station with pump as supplied by Anchorage
Tank. The specifications for this and other systems has already been supplied to your
department including the pump, pump curves, pump sizes and pump capacities.
The hole spacing for the system is already shown and is correct. The lateral diameter
is dearly shown on Sheet S2 of the submitted plans.
The only evidence of the existing absorption field is a single deanout. Using
the approved inspection report, one would have to assume the approximate
location of the system. There is no reasonable way in which to verify the exact
location of the field. However, it is my opinion from field observations that the new
system will be at least 10 feet from the old one.
6. Plan for existing system:
The existing system is quite old and also quite full; pumping has been
necessary during portions of the year to prevent backup. Considering the age of the
system, it would be safe to presume that abandonment would be in order. In the
absence of a dear statement by the engineer that the old field might be retained for
later use, one could easily assume that such wasn't the case. Incidentally, I find no
evidence in the currently adopted Uniform Plumbing Code which requires
abandonment of a deep trench. However, we do plan to abandon in place.
RECEIVED
DEO 0 B 1995
t~tu,~ c pa ty o! Anchorage
Dept. Health & Human Serv ces
Subject: Lot 38, Track B, Eagle Crest Subdivision - Sewer Upgrade
I:~emberb= 1995
?a~e3of3
Precious time has been lost in our attempt to install this system before we ~e
~e~uded b~ we~e~. Z ~md ~e ~bove co~en~ bo~ ~ecess~ ~d ~ ~:t ~o~-
re~ato~, and point out ~t ~ey have delayed ~e installation and si~ic~fly
~geased ~e overall cost for i~ com~ucfion. I am re~ng ~e pe~t app~cafion
~ all items noted on November 30 ad~essed. I do ~s under protest as outed
in ~is letter. In order to avoid any additional delays and damages, I would
appredate it ff you could e~edite ~e ~suance of ~e up~ade per~t for ~e above
properS.
Respectfully submitted,
attachments:
On-Site Services Transmittal Sheet
Revised Site Plan dtd 12/4/95
Revised Design Details dtd 12/4/95
RECEIVED
OEO 0 8 1995
~,lunic~pality of Anchorage
Dept. He,~ th & Human Services
SITE PLAN
WASTEWATER DISPOSAL SYSTEM
LOT 38, TRACK B, EAGLE CREST SUBDIVISION
P.I.D. 050-291-12
FIRST STREET
~///.,~
VACANT VACANT
RECEIVED
DEC 0 8 1935
Munimpality of Anchora~
PREPARED FOR: KND
20441 PTARHIGAN DLVD
I~RAD LOR£NZEN EAGLE RIVER, AK, 99577
87E0 IVANHnE STREET (907)696-6111~FAX(907)696-8111
INDIANAPOLIS, IN
(317)897-6818
DESIGN
ASTE /ATER
LOT 38, TRACT B,
CONNECT TO 4" SDLII] FRON EXISTING TANK
~ ~ .--FINISHED ('iRABE
P.I.D. 050-291-12
DETAILS
DISPOSAL SYSTEH
EAGLE CREST SUBDIVISION
INSULATION.---.-._. ~FILT£R FABRIC
SEWER ROCK
BOTTOM OF TEST HOLE 11.0'
VATER OBSERVED 9.5'
1. RESIDUAL HEAD - 5'
2. HOLE SIZE = 3/16' : 1.00 GAL. PER HOLE e 30 PSI
3. 30 GALS (PUHP DELIVERY)/LO0 GALS./HOLE - 30 HOLES
4. 48 LF LATERAL/30 HOLES - 1.5[' SPACING PER HOLE
5. ALL HOLES SHALL HAVE CAPS INSTALLED PER MANUFACTURERS SPECS.
6. PUHP USED IN LIFT STATION - 20 OS[ 05 HHF-5
500 GAL I M.T.i(j
DESIGN CRITERIA
1. 3 BEDROOMS X 150 GAL./DAY/DEDRDOM - 450 GPD
2. SOILS RATING, 1.2 MIR/INCH = 1.2 GPD/SF(TRENCH)
3. 450 GPD/I.2 GPO PER SF - 375 SF
4. 375 SF /5' V x 0.64 = 48' k (USE I TRENCHS 48 L)
5. MININUN DESIGN SIZE = 48' L x 5' V x 2.5' D Trench
6. 2' HD INSULATION REQUIRED OVER FIELD <3' OF COVER
7. CONTRACTOR TO PUMP TANK AS NEEDED.
8, CONTRACTOR TO VERIFY YELL SEPARATION ~ISTANCES TO
SYSTEM PRIOR TO INSTALLATION FROM ALL ADJACENT VELLS.
9. ANY ASPHAL~ CONCRETE OR APPERTANENCES DAMAGED OR
H
10.
11.
DESTROYED ~Y THE CONTRACTOR DURING CONSTRUCTION SHALL DE
REPLACED DY THE CONTRACTOR AT NO ADDITIONAL COST TO THE O~NER.
CONTRACTOR TO VERIFY AND INSURE 2Z GRADE FROM EXISTING TANK.
CONTRACTOR TO EXCAVATE TANK IN ORDER TO VERIFY INTEGRITY.
PREPARED FOR:
DRAD LORENZEN
87~0 IVANHOE STREET
INDIANAPOLIS. IN
(317)897-6818
KND ENGINEERING
20441 PTARMIGAN BLVD
EAGLE RIVER, AK, 99577
(907)C96-6111/FAX(907)$96-8111
Mu.ic,pality of Anchorage
Oept. Heelth& Human Services
I~JNICIPAgl~ OF ANC, H
jNVIi~ONM,~.NTAL SERVICI~S DIVISION
D£C 0 8 1995
20441 PTARMIGAN BLVD.
WR, 99S -S 6 r I V D
December 5, 1995
Munidpality of Anchorage
Dept. of Health & Human Services
On-Site Services Section
P. O. Box 196650
Anchorage, Alaska 99519-6650
ATTN: James Cross, P.E.
RECEIVED
DEC 8 1995
D tvlun,;c;palily el Anchorage
e~t. Health & Human Services
Subject: Lot 38, Tract B, Eagle Crest S/D - Sewer Upgrade
Dear Mr. Cross:
On December 1, the sewer upgrade permit application for the subject lot was
returned to me with a list of 11 items for correction. A copy of the cover sheet is
attached for your reference.
I take exception to a number of the deficiences listed by the reviewer. Those are as
follows:_.,~, .-~
/.,~,~-
1. Inadequate site plan:
Our submittal does co~ly with regulations. The lots to the south and
southeast are vacant, wMle the lot to the southwest is developed. This developed
lot's well is greater than 100 fe~t.froTM our proposed upgrade and ~11 not impa~ ~e
installa~on. Since ~e o~er lots were vacant land, I have sho~ no~ng on ~em.
2. Labels missing:
O~ site plan is dra~ to scm~ as re~mrea m coae, aha as su~ all ~adii sho~
are also to scale. There is ~o r~quireme~t ~or additional identification; ~r~ is
actuMly ~o requirement ~or w~ll radii at all, but they ~ava ~ee~ sho~ ~or
convenience sake.
The request for labeling on the proposed trench, tank, etc., is answered on
page S2 of my submittal. Although it may be the practice of some firms to place all
information on one sheet, I have found that by providing 2 sheets I can more clearly
show the proposed system both for the reviewer and for the contractor.
Subject: Lot 38, Track B, Eagle Crest Subdivision o Sewer Upgrade
DecemberS',, 1995
Page2of3
Inspection of old septic tank:
My submittal letter dearly states that the existing septic tank is fiberglass. As
you are probably aware, the old Sunset Plastics septic tanks were manufactured
using questionable loading calculations, and hence any breach to their integrity
caused a collapse of the tank. That is to say, either the tank is whole and intact, or is
not. If it is not, we will naturally replace it at 100 feet from the well.
4. Well to tank distance:
It is apparent that the original waiver request was based on a measurement
made from the cleanout to the well, since no excavation was attempted. Since there
is no information on file as to the exact size of this fiberglass tank, I used the
dimensions of a 1250 steel tank to approximate the location of the tank with the
deanout pipe located in the center. The cleanout pipe is exactly located by a licenced
surveyor. Based on the above and research to date there is no method in which to
assert that the separation distance is less than 95 feet short of e~cavating the tank.
For the sake of clarity, ! have sketched in a possible tank location.
Information on pump size, description, and hole spacing, absorption field
location:
This is a standard application lift station with pump as supplied by Anchorage
Tank. The specifications for this and other systems has already been supplied to your
department including the pump, pump curves, pump sizes and pump capacities.
The hole spacing for the system is already shown and is correct. The lateral diameter
is clearly shown on Sheet S2 of the submitted plans.
The only evidence of the existing absorption field is a single deanout. Using
the approved inspection report, one would have to assume the approximate
location of the system. There is no reasonable way in which to verify the exact
location of the field. However, it is my opinion from field observations that the new
system will be at least 10 feet from the old one.
6. Plan for existing system:
The existing system is quite old and also quite full; pumping has been
necessary during portions of the year to prevent backup. Considering the age of the
system, it would be safe to presume that abandonment would be in order. In the
absence of a clear statement by the engineer that the old field might be retained for
later use, one could easily assume that such wasn't the case. Incidentally, I find no
evidence in the currently adopted Uniform Plumbing Code which requires
abandonment of a deep trench. However, we do plan to abandon in place.
Subject: Lot 38, Tr~ck S, Ea$1e Crest Subdivision - Sewer Upg~cle
Decemberb', 1995
Pa~e3of3
Precious time has been lost in our attempt to install this system before we are
precluded by weather. I find the above comments both unnecessary and in part non-
regulatory, and point out that they have delayed the installation and significantly
increased the overall cost for its construction. I am returning the permit application
with all items noted on November 30 addressed. I do this under protest as outlined
in this letter. In order to avoid any additional delays and damages, I would
appreciate it if you could expedite the issuance of the upgrade permit for the above
property.
Respectfully submitted,
attachments:
On-Site Services Transmittal Sheet
Revised Site Plan dtd 12/4/95
Revised Design Details dtd 12/4/95
~/ASTE~/ATER DISPOSAL SYSTEM
T 38, TRACK B, EAGLE CREST SUBDIVISIBN
P.I.D. 050-291-12
FIRST STREET
23
YELL AREA
VACANT ~,, VACANT
PREPARED FOR:
~RAD LBRENZEN
87~0 IVANHOE STREET
INDIANAPOLIS, IN
(317)897-6818
KND ENGINEERING
20441 PTARMIGAN BLVD
EAGLE RIVER, AK, 99577
(907>696-6111/FAX(907)696-8111
November 17, 1995
Munidpality of Anchorage
Dept. of Health & Human Services
On-Site Services Section
P. O. Box 196650
Anchorage, Alaska 99519-6650
Subject: Lot 38, Track B, Eagle Crest Subdivision - Sewer upgrade
Gentlemen:
Following an adequacy test in which the existing system failed, we dug one testhole
for the proposed upgrade. The result of that test is attached.
The upgrade will be placed on the southeast portion of the lot. Due to the grade
differential we will have to use a lift station in order to reach the field. As the
existing septic tank is fiberglass we anticipate its continued use as it will maintain a
gravity flow from the house to the lift station.
Natural drainage is away from this site and will be maintained after construction.
There is no surface water within 100' of the proposed installation. There are no
curtain drains within 50' of the proposed installation. No wells exist within 100' of
the proposed installation.
Due to the onset of winter we are requesting an expedited permit in order to
mitigate the depth of frost.
If you have any questions about this application, please call me at 696-6111/FAX 696-
8111.
Respectively submitted,
Kenneth M. Du u~s, P. E.
KND Engineering
attachments:
On-Site Well and Sewer Application
Wastewater Absorption System Details
Site Plan
Soils Log/Percolation Test
Municipality of Anchorage
DEPARTMENT OF HEALTH & HUMAN SERVICES
825 "L" Street. Anchorage. Alaska 99502-0650
SOILS LOG ~ PERCOLATION TEST
PERFORMED FOR:
LEGAL DESCRIPTION: Zo~'-~ "~/P-.AcT~c~ ~AG/..E'~_.~_,,~)"l'ownship, Range, Section:
SLOPE SITE PLAN
WAS GROUND WATER
ENCOUNTERED?
6-
7-
8-
9-
10-
11 EkD./4.
12
13
14
15
16
17-
18-
19-
20-
IF YES. AT WHAT
DEPT.? q,5' '
I
N
g
,*7 rt.
~lonitoring? 7' ~ Dile:
Reading Date Gross Net I~th to Net
Time Time Water Drop
7 7 ~,~ / ~n ~ Y~" /"
PERCOLATION RATE /'(? Im~nutes/mch) PERC HOLE DIAMETER ~' /'
TEST RUN SETWEEN ~* FT AND ~ FT
COMMENTS
ACCORDANCE WITH ALL STATE AND MUNICIPAL GUIDELINES IN EFFECT ON THIS DATE. DATE;
CERTIFY THAT THIS TEST WAS PERFORMED IN
! !
MUNICIPALITY OF ANCHORAGE
Development Services DepartmentPhone: 907-343-7904
On -Site Water & Wastewater Section Fax: 907-343-7997
Parcel I.D. 050-291-12
1
Certificate of On -Site Systems Approval
Expiration Date: 119 -1713 -WW
GENERAL INFORMATION
Complete legal description Eagle Crest ##1, TR B, Lot 38
Location (site address) 19114 1 st Street Eagle River, AK
Current property owner(s) Rebecca Pasley Day phone 854-0059
Mailing address
Real estate agent
19114 1 st Street, Eagle River, AK 99577
2. TYPE OF DWELLING:
0 Single Family (w/wo ADU)
❑ Duplex
❑ Multiple Dwellings (Single Family and/or Duplex)
Day phone
3. NUMBER OF BEDROOMS:
3
4. TYPE OF WATER SUPPLY:
TYPE OF WASTEWATER DISPOSAL:
Private Well
Fx_1
Private Septic
0
Water Storage
❑
Holding Tank
❑
Community Well
❑
Community
❑
Public Water System
❑
Public Sewer
❑
Waiver request for: Distance:
Received by: Date:
COSA to be released to the engineer, unless otherwise requested by the engineer.
COSA Fee $ J . 5 0
Date of Payment
Waiver Fee $
020 Date of Payment
Receipt Number 0 b$ d 3 b
COSA # 0 SC 2-01319
Receipt Number
Waiver #
5. STATEMENT OF INSPECTION BY ENGINEER
As certified by my seal affixed hereto and as of the validation date shown below, I verify that my investigation, based
on procedures outlined in the Certificate of On -Site Systems Approval Guidelines for this application, shows that the
on-site water supply and/or wastewater disposal system is (are) safe, functional and adequate for the number of
bedrooms and type of structure indicated herein. I further verify that based on the information obtained from the
Municipality of Anchorage files and from my investigation and inspection, the on-site water supply and/or wastewater
disposal system is (are) in compliance with all applicable Municipal and State codes, ordinances, and regulations in
effect at the time of installation. I acknowledge that On -Site staff may visit the site to verify the information submitted.
Name of Firm Forge Engineering Phone 907-522-7773
Address 1399 W. 34th Ave Suite 101, Anchorage AK 99503
Engineer's Printed Name Michael E. Anderson, P.E. Date 7/7/2020
OF tAVL,
JU ,
ON'
A O z �-
PS�''�` I AT
ii0MENT SER��`�,,
Original Certificate Date: 7.23 " 4?c) 2C)
The Municipality of Anchorage Development Services Division (DSD) issues Certificates of On -Site Systems Approval (COSA) based only upon the
representations given in paragraph 5 by an independent professional civil engineer registered in the State of Alaska. The Municipality of Anchorage is
not responsible for errors or omissions in the professional engineer's work.
7. ATTACHMENTS:
COSA Checklist X Nitrate Advisory
Septic System Advisory Arsenic Advisory
Well Flow Advisory Other
COSA Checklist blue sheet
OF
��P E •
0
AN ;
6. DSD SIGNATURE
m j_,, j_Cal�T ®
System #1 Approved for
bedrooms MICHAEL E. ANDERSON p fLp
System #2 Approved for
No. CE -4381 ;' _;
17
bedrooms 7ni20. �4.�®
Disapproved
o°®�PROFES ®(:�\ ® 0
Conditional approval for
bedrooms, with the following stipulations:
OF tAVL,
JU ,
ON'
A O z �-
PS�''�` I AT
ii0MENT SER��`�,,
Original Certificate Date: 7.23 " 4?c) 2C)
The Municipality of Anchorage Development Services Division (DSD) issues Certificates of On -Site Systems Approval (COSA) based only upon the
representations given in paragraph 5 by an independent professional civil engineer registered in the State of Alaska. The Municipality of Anchorage is
not responsible for errors or omissions in the professional engineer's work.
7. ATTACHMENTS:
COSA Checklist X Nitrate Advisory
Septic System Advisory Arsenic Advisory
Well Flow Advisory Other
COSA Checklist blue sheet
Legal Description: Eagle Crest #1, TR B, Lot 38
If more than 1 septic system on lot: COSA Checklist # of
A. WELL DATA
❑ Well log is filed with Onsite (or attached)
Date drilled 5/6/75
Total depth 213 ft
Cased to 213 ft
❑ Sanitary seal is functioning correctly
❑ Wires are properly protected
Casing height (above ground) < 12 in.
Date of flow test for COSA 4/8/19
Static water level at beginning of test 194 ft.
Comments
B. TANK DATA
Age of tank(s) <1 years
Tank type/material S.T.E.P./Plastic
Measured operating fluid level in septic tank New
❑ Standpipes/foundation cleanout per record drawing
Date of pumping New Construction 9/26/19
D. ABSORPTION FIELD DATA 5' Wide Shallow Trench
Which system tested (date installed) 6/12/96
❑ ALL standpipes present per record drawing
Total measured depth from grade 5.1 ft (max)
Measured depth to pipe invert from grade 2.6 ft (min)
❑ N/A — pressurized field
❑ Monitor tubes go to bottom of effective. If not, state
depth into effective
❑ Code -required soil cover over field
❑ System presoaked
(Required if vacant for greater than 30 days prior to
date of test)
Gallons introduced NA gallons
Comments/Deficiencies:
COSA Checklist yellow sheet
Parcel ID: 050-291-12
Structure served by this system
Well production at time of test 4.8 gpm
Water storage tank volume None gallons
Well disinfected for coliform test? ❑ Yes ❑ Nc
❑ Coliform bacteria is Negative
Nitrate 1.32 mg/L ❑ Nitrate less than MRL (ND)
Arsenic ug/L ❑ Arsenic less than MRL (ND)
Collected by FORGE ENGINEERING
Date of Sample
C. LIFT STATION
❑ Required maintenance completed
Age of lift station <1 years
Lift station material Plastic
Comments:
New Construction 9/26/19
Adequacy test date 4/8/19
Results ❑✓ Pass For 3 bedrooms
Fluid depth prior to test 0 in
Water added 744 gal
New depth 0 in
Elapsed time 0 min
Final fluid depth 0 in
Absorption rate >450 gpd
Any rejuvenation treatment (past 12 months)
If yes, enter date
m
E. SEPARATION DISTANCES
From Private Well on Lot to: (Please enter distances if less than required or if community well)
Septic Tank/Lift Station on Lot > 100'
Q
Yes
Community Sewer Manhole/Cleanout > 100'
Q Yes
if No
ft
0 Yes
if No ft
Neighboring Tank > 100' F/7 Yes
if No
ft
Private Sewer/Septic Line > 25' 0 Yes
if No ft
Absorption Field on Lot > 100' 0 Yes
if No
ft
Holding Tank > 100' Yes
if No ft
Neighboring Absorption Fields > 100'
M✓ Yes if No _
Water Main > 10'
Animal Containment > 50' ✓1 Yes
if No ft
F/ Yes
if No
ft
M Yes if No_
Water Service Line > 10'
Yes
if No
Manure/Animal Excreta Storage > 100'
-❑✓
If septic tank is under driveway
Community Sewer Main > 75' 0✓ Yes
if No
ft
Yes
if No ft
From Septic/Holding Tank on Lot to: (Please enter distances if less than required)
Building Foundations > 10'
Q
Yes
if No
ft
Surface Water > 100'
Yes if No.
Property Line > 5'
❑✓
Yes
if No
ft
Wells on Adjacent Lots:
Absorption Field > 5'
❑✓
Yes
if No
ft
Private Wells > 100'
M✓ Yes if No _
Water Main > 10'
✓V
Yes
if No
ft
Community Wells > 200'
M Yes if No_
Water Service Line > 10'
Yes
if No
ft
If septic tank is under driveway
comment below
From Absorption Field on Lot to: (Please enter distances if less than required)
Building Foundation > 10'
E✓
Yes
if No
ft
If absorption field is under driveway comment below
Property Line > 10'✓71
Yes
if No
ft
Wells on Adjacent Lots:
Water Main > 10'
Yes
if No
ft
Private Wells > 100' ❑✓ Yes if No
Water Service Line > 10'
Q
Yes
if No
ft
Community Wells > 200' Yes if No
Surface Water > 100'
✓�
Yes
if No
ft
F. ENGINEER'S COMMENTS
G. ENGINEER'S CERTIFICATION
l certify that 1 have determined through field inspections and review
of Municipal records that the above systems are in conformance with
MOA COSA guidelines in effect on this date.
COSA Checklist yellow sheet
'
�. .OF 44
��ssassasasss
/ °°° ° `O•°'fid
gyp° 49th
sasasis •saes■ sesa ssssasa sass Rt�
0
0°°�tt 4g6°1C°stta°64°[Ct Ca6q®lia/°Ct9---- ---
�`C`C�1�` m MICHAELE. ANDERSONAV
.
No. CE -4381 +° AVZIV
7/7/20Nil, el'OROF E SS • °� 4,C��
'!Fh °t°®sesnasssss°O°° �-
ft
ft
ft
ft
ft
Municipality of Anchorage
Development Services Department
Building Safety Division
On-Site Water and Wastewater Program
4700 Bragaw Street
P.O. Box 196650
Anchorage, AK 99519-6650
www.muni.org/onsite
(907) 343-7904
CERTIFICATE OF ON-SITE SYSTEMS APPROVAL
FOR A SINGLE FAMILY DWELLING
Parcel I.D. o5o-29~.-~-:z
1. GENERAL INFORMATION
Complete legal description Eagle Crest #z Tract B, Lot 38
Expiration Date:
Location (site address) ~gzz4 First St., Eagle River
Current Property owner(s) Micalle Culver
Day phone 727-848o
Mailing address
~-~-73o Birch Knoll Loop, Anchorage, AK
Lending agency
Day phone
Mailing address
Real Estate Agent Micalle Culver
Mailing Address
t "¢' ."., . /
. Unle'ss'Other~v~b'~: requested, COSA will be held by DSM for pickup.
,'2.' 'NUMBER OF BEbROOMS:
Day phone 7~7-848o
3~
TYPE OF WATER SUPPLY:
,,Individual Well:.
I'ndividual 'Water Storage
Community Class ~
Public Water System
Well
TYPE OF WASTEWATER DISPOSAL:
[] Individual On-site [~
[] Individual Holding Tank E]
[] Community On-site E~]
[] Public Sewer r-I
The Municipality of Anchorage Development Services Department (DSM) issues Certificates of On-Site Systems
Approval (COSA) based only upon the representations given in paragraph 4 by an independent professional civil
engineer registered in the State of Alaska. Certificates of On-Site Systems Approval are required for the transfer of
title (except between spouses) for properties served by a single-family on-site wastewater disposal and/or water
supply system. DSM also issues COSAs upon request to homeowners. Certificates of On-Site Systems Approval
are valid for 90 days from the date of issue for properties served by a private or Class C well and may be reissued
with new water sample results. (Certificates may be reissued for a period of up to one year with valid water
samples.) Certificates are valid for one year for properties served by Class A or B wells or a public water system.
The Municipality of Anchorage is not responsible for errors or omissions in the professional engineer's work.
4. STATEMENT OF INSPECTION BY ENGINEER
As certified by my seal affixed hereto and as of the validation date shown below, I verify that my investigation,
based on procedures outlined in the Certificate of On-Site Systems Approval Guidelines for this application,
shows that the on-site water supply and/or wastewater disposal system is (are) safe, functional and adequate
for the number of bedrooms and type of structure indicated herein. I further verify that based on the information
obtained from the Municipality of Anchorage files and from my investigation and inspection, the on-site water
supply and/or wastewater disposal system is(are) in compliance with all applicable Municipal and State codes,
ordinances, and regulations in effect at the time of installation.
Name of Firm Pannone Engineering Services, LLC Phone 27:~-82~8
Address P.O. Box ~oo2~7, Anchorage, AK 99~;~o
Engineer's Printed Name Steven R. Pannone, P.E. Date 81ql~-~-
Engineers Comments: In conducting an adequacy test, ! attempt to pro¥ide a thorough, conscientious engineering analysis of the system in
accordance with MOA DSD Guidelines & Regulations. The reported results describe the performance of the system under the conditions
encountered at the time of the test, and separation distances measured to readily identifiable features.
The operational life of all wells and septic systems depend on the local soil condition, ground water
levels that may fluctuate during the year, and the water usage of the family being served by the system.
These conditions are outside the control of the evaluator of this system. All systems eventually fail and
satisfactory test results do not guarantee future performance of the system, nor do they guarantee that
there are no hidden defects or encroachments. PES can therefore not provide any warranty for future
performance nor give any estimate of how long the system will continue to meet the operational
requirements of the MOA DSD. The content of this report is for the sole benefit of the owner listed
above. Any reliance upon or use of this report by any other person or party is not authorized nor will it
confer any legal right whatsoever.
5. DSD SIGNATURE
¥'""'" Approved for ~ bedrooms.
Disapproved.
Conditional approval for
bedrooms, with the following stipulations:
Attachments:
COSA Checklist
Septic System Advisory
Well Flow Advisory
Nitrate Advisory
X
Arsenic Advisory
Maintenance Agreements
Supplemental Engineer's Report
Other
Original Certificate Date:
Municipality of Anchorage
Development Services Department
Building Safety Division
On-Site Water & Wastewater Program
4700 Bragaw Street
P.O. Box 196650
Anchorage, AK 99519-6650
www.muni.org/onsite
(907) 343-7904
CERTIFICATE OF ON-SITE SYSTEMS APPROVAL CHECKLIST
Legal Description:
A. WELL DATA
Eagle Crest #~ Tract B, Lot ~8
Parcel ID: 050-2q~.-:!.2
Well type Private
Date completed ~;1613.q7~
Total depth 2~3 ft.
If A, B, or C provide PWSID # __
Sanitary seal (Y/N) Y
Cased to :~z~ ft.
Date of test
Static water level ~.98
Well production ~o
WATER SAMPLE RESULTS:
Coliform ~colonies/100 mL
Arsenic: ND ug/I
SEPTIC/HOLDING TANK DATA
Tank Type/Material S.T.E.P. / Steel
Tank size ~2~;o gal.
Foundation cleanout (Y/N) Y
Date of pumping ~:,l~.~l:zo',o
ABSORPTION FIELD DATA
FROM WELL LOG
~;/6/~q75
g.p.m.
Nitrate (~)~/(mg/L
Date of sample: 81ql=oz=
Number of Compartments _~
Depression over tank (Y/N) N
Pumper JR's Pumping
Well Log (Y/N)Y
Wires properly protected (Y/N) Y
Casing height (above ground) ~
AT INSPECTION
ag~ ff.
6.9+ g.p.m.
in.
Other bacteria~.-~ cOlonies/100 mL
Collected by: Steve Pannone
Date installed 61~21~qq6
Cleanouts (Y/N) Y
High water alarm (Y/N) Y
Date installed 6/~2/[qq6 Soil rating (g.p.d./ft2 or ~/bdrm) ~.~ GPD/SF
Length 49.5 ff. Width 5
Total depth ~.7 ff. Eft. absorption area :~86.7 fi2
Date of adequacy test ~z/2~/~o~o Results (Pass/Fail) ~
Fluid depth in absorption field before test _o in.
Elapsed Time: z~o min. Final fluid depth _o in.
Any rejuvenation treatment (past 12 mo.) (Y/N & type) N
System type Shallow Trench
ft. Gravel below pipe
Monitoring tube Y Depression over field N
Pass For 3 bedrooms
Water added485 gal. New depth_~ in.
Absorption rate >= 45o+ g.p.d.
If yes, give date
fto
LIFT STATION
Date installed 61~213.996
"Pump on" level at _~ in.
Datum Bottom
E. SEPARATION DISTANCES
Size in gallons 250
"Pump off" level at ~ in.
Cycles tested :1
Manhole/Access (Y/N) Y
High water alarm level at/~/~
Meets alarm & circuit requirements? Y
in.
SEPARATION DISTANCES FROM WELL ON LOT TO:
Septic tank/lift station on lot 3.oo+
Absorption field on lot 3.oo+
Public sewer main
Sewer/septic service line 25+
Animal containment areas 5o+
On adjacent lots 3.00+
On adjacent lots 3.00+
Public sewer manhole/cleanout 3.00+
Holding tank ~00+
Manure/animal excrete storage areas
lOO+
SEPARATION DISTANCES FROM SEPTIC/HOLDING TANK ON LOT TO:
Building foundation 3.0+ Property line 3.0+
Water main 3.0+ Water service line ,25+
Wells on adjacent lots 3.00+
SEPARATION DISTANCE FROM ABSORPTION FIELD ON LOT TO:
Absorption field
Surface water
Property line 3.o+
Water Service line
Curtain drain 5o+
COMMENTS
Building foundation 10+
Surface water 3.00+
Wells on adjacent lots 3.oo+
Water main 75+
Driveway, parking/vehicle storage 3.0+
G. ENGINEER'S CERTIFICATION
I certify that I have determined through field inspections and
review of Municipal records that the above systems are in
conformance with MOA COSA guidelines in effect on this date.
Engineer's Printed Name Steven R. Pannone, P.E.
Date
COSA Fee $
Date of Payment
Receipt Number
(Rev. 11/05)
Waiver Fee $
Date of Payment
Receipt Number
Municipality of Anchorage
Development Services Department
Building Safety Division
On-Site Water and Wastewater Program
4700 Bragaw Street
P.O. Box 196650
'Anchorage, AK 99519-6650
www. muni.org/onsite
(907) 343-7904
CERTIFICATE OF ON-SITE SYSTEMS APPROVAL
FOR A SINGLE FAMILY DWELLING
Parcel I.Di O50-291-12
GENERAL INFORMATION
Complete legal description Eagle Crest #~.Tract B, Lot 38
Location (site address) x%~-6 First St., Eagle River
COSA # (.~(~
Expiration Date:
Current Property owner(s) Earl & Robin Conaway
Mailing address
Day phone
Lending agency
Mailing address
Day phone
Real Estate Agent
Bethany Stamper ! Coldwell Banker
MailingJ~ldres~ -.
'Utile'Ss other~;~$~,~gquested, OOSA will be held by DSD for piokup.
TYPE OF ,WATER S~PPLY:
Individual Well' ~
Individual ~ater Storage ~
Community Class Well ~
Public Water System
Day phone
TYPE OF WASTEWATER DISPOSAL:
Individual On-site
Individual Holding Tank
Community On-site
Public Sewer
The Municipality of Anchorage Development Services Department (DSD) issues Certificates of On-Site Systems
Approval (COSA) based only upon the representations given in paragraph 4 by an independent professional civil
engineer registered in the State of Alaska. Certificates of On-Site Systems Approval are required for the transfer of
title (except between spouses) for properties served by a single-family on-site wastewater disposal and/or water
supply system. DSD also issues COSAs upon request to homeowners. Certificates of On-Site Systems Approval
are valid for 90 days from the date of issue for properties served by a private or Class C well and may be reissued
with new water sample results. (Certificates may be reissued for a period of up to one year with valid water
samples.) Certificates are valid for one year for properties served by Class A or B wells or a public water system.
The Municipality of Anchorage is not responsible for errors or omissions in the professional engineer's work.
4. STATEMENT OF INSPECTION BY ENGINEER
As certified by my seal affixed hereto and as of the validation date shown below, I verify that my investigation,
based on procedures outlined in the Certificate of On-Site Systems Approval Guidelines for this application,
shows that the on-site water supply and/or wastewater disposal system is (are) safe, functional and adequate
for the number of bedrooms and type of structure indicated herein. I further verify that based on the information
obtained from the Municipality of Anchorage files and from my investigation and inspection, the on-site water
supply and/or wastewater disposal system is(are) in compliance with all applicable Municipal and State codes,
ordinances, and regulations in effect at the time of installation.
Name of Firm Pannone Engineering Services, LLC Phone 272-82~8
Address P.O. Box ~-oo2:~7, Anchorage, AK 995~o
Engineer's Printed Name Steven R. Pannone, P.E. Date
Engineers Comments: In conducting an adequacy test, I attempt to provide a thorough, conscientious engineering analysis of the system in
accordance with MOA DSD Guidelines & Regulations. The reported results describe the performance of the system under the conditions
encountered at the time of the test, and separation distances measured to readily identifiable features.
The operational hfe of all wells and septic systems depend on the local soil condition, ground water
levels that may fluctuate during the year, and the water usage of the famil bein served b the s stem
These conditions are outside the control of the evaluator of this system. ~11 sy~tgems eventYually ~;il an'd _~'*c~9~,,;
satisfactory test results do not guarantee future performance of the system, nor do they guarantee that i
there are no hidden defects or encroachments. PES can therefore not provide any warranty for future ,~,,,,.'~,~..~ ......... .~,,,,,~
performance nor give any estimate of how long the system will continue to meet the operational ~-
requirements of the MOA DSD. The content of this report is for the sole benefit of the owner listed
above. Any reliance upon or use of this report by any other person or party is not authorized nor will it '~°~'¢~-.,. No. C[
confer any legal right whatsoever. ~"
5. DSD SIGNATURE
Approved for .D bedrooms.
Disapproved.
Conditional approval for bedrooms, with the following stipulations:
Attachments:
COSA Checklist
Septic System Advisory
Well Flow Advisory
Nitrate Advisory
X
Arsenic Advisory
Maintenance Agreements
Supplemental Engineer's Report
Other
Original Certificate Date: / ~ - ..~ ~2.-//O
E)kate~ test
· e,, g:p':m.
Am." ND: ugtt-
E .,lapsed Time:.~,~e,min~ Fi, r~l/, ,~: ~ deptE.,_o ,iff,
Any rqUv~ ~,(;paek 12..~.) (¥~;&'bjpe)' N
· For 3bedrooms
,~,n 'r~e >=- ~, g:~p~d.
'If yes~ g~ ~:
D~ UFT'ST~TK)N
Date, installed:
"Pump on,level at .~ in.
Datum
E.
F;
Sizein :gallons 2Se
"Pump: off" level at ~3. in.
C~ tested, 3
Manhol~Accees (Y/NJ Y
HighWater alan~ level: at 44
Meets alarm & circuit requirements? ,Y,
. in.
SEPARATION~:,;BtSTANC_~S,F~ WELL ON LOT TO:
Septic ,tan~ffft stetion ea: ~ot
Absorption field on ~let.
Pablic sewer main 75+
Sewer Ise~ ~rvice a~e .=~+
Ard~mai oo~nt areas 5o.
On adJaCent ~
On adjacent lots
Public sewe~ ma~llole/cleanout
Holding.tank .. ~oo+
Manure/ardma! excrete sterage~amas ~.oe+
SEPARATIO~D~STAN(:~S F~ SEPTIC/HOLDING TANK ON LOT TO:
Bu, ildiag foUn ~ ~, ~n ~,0~. Properbj line
Water*main 3~. Water serviceline ~+
Wel~son ad~ ~mce~t lots ~eo+
SEPARATION~iCE FRO~ABSORPTION FIELD ON LOTTo:
Pm~ ;line
Water Service:~e
CUrta{n d~n
Budding fo~dation ~o+
Su~ace water
~on adjacent.Jots .~o~+
Absorption field
Surface water
Water main. 75+
-Ddvewa¥.~:paridr~tvehicle s~rage ..,.~.o+
~ i~spections and
in
EngiReer~s Primed Name stev~a.J~~,.p.E.
Date
Waiver 'Fee:.$
Date or'Payment
Receipt Number
R. Ponn
No. CE 81~-9
1st STREET
8355M
LOT 39
LOT 46
Keybox.~
N89°58'00"W 132.00
fYard light/wood
~ wall
48.0
ret.
0
0
~;hain link fence
LOT 38
~ I 1/2 Story Frame
House
20.0 o o 16.0
deck
deck ~
II[lflml][][[ J~ 'CO
o
Septic vents
~)Sepflc tank
Septic vent
Yard light~'~'
she~
10' Utility Easement
132.00
N89°58'00,,W
~Septic vent
LOT 47
LOT 37
SCALE: 1": 30'
LOT 48
.... .:..
/ ....,.~ -~r
'1,~. No. 32~-S
EASEMENTS OF RECORD, OTHER THAN '
THOSE SHOWN ON THE RECORDED
PLAT ARE NOT SHOWN HEREON. Fb 10-7. pg 71-72
BLS BE
AS-BUILT NO CORNERS SET THIS DATE
hereby certify that ~ have performed a Mortgagee's inspection
of the following described property: LOT 38. TRACT B,
EAGLE CREST SUBDIVISION, FIRST ADDITION
Anchorage Recording Precinct, Alaska, and that the
improvements situated thereon are within the prope~'y lines
and do not ovedap or encroach on the property lying
adjacent thereto, that no improvements on the property lying
adjacent thereto encroach on the premises in question and
thai; there are no roadways, transmission lines or other
visible easements on said property except as indicated
hereon.
Dated at Anchorage, Alaska
this 12th day of November ,2010
FRED WALATKA & ASSOCIATES
Engineers and Surveyors
(907-248-1666)
MUNICIPALITY OF ANCHORAGE
DEPARTMENT OF. HEALTH & HUMAN SERVICES. --
Division of Environmental Services
On-Site Services Section
P.O. Box 196650 Anchorage. Alaska 99519-6650
343-4744
Parcel I.D. #
CERTIFICATE OF HEALTH AUTHORITY
APPROVAL FOR A SINGLE FAMILY DWELLING
GENERAL INFORMATION
Complete legal description
Location (site address or directions)
Property owner
Mailing address
Lending agency
Mailing address
Day phone
Day phone
Address
Day phone
2. NUMBER OF BEDROOMS:
3. TYPE OF WATER SUPPLY:
Unless otherwise requested, HAA will be held for pickup.
NOTE:
Individual well
Community well
Public water
If community well system, provide written confirmation from State ADEC attest-
ing to the legality and status of system. - ................
4. TYPE OFWASTEWATER DISPOSAL:
NOTE:
.Z
Individual on-site
."Holding tank
Community on-site
Public sewer
If community wastewater system, provide Written confirmation from State ADEC
attesting to the legality and status of system.
Se
STATEMENT OF INSPECTION BY ENGINEER
AS certified by my seal affixed heretc~ an~'as ~)'~'the-vaiidation da~e shown belc~W/I-verif~ tl~at m~,
investigation of this Health Authority Approval application shows that the on-site water supply
and/or wastewater disposal system is safe, functional and adequate for the number of bedrooms
and type of structure indicated herein. I further verify that based on the information obtained from
the Municipality of Anchorage files and from my investigation and inspection, the on-site water
supply and/or wastewater disposal system is in compliance .with all Municipal and State codes,
ordinances, and regulations in effect on the date of this inspection.
Name of Firm KND En,qineerin,q Phone ~'~/~ -/~/'/'//
2(~,41 Ptarmigan Blvd.
Address Eaqle River, A~
Engineer's signature ~. /~,~--- Date ~'/~;?/~'/
DHHS SIGNATURE
~. Approved for ~-"~/~?~'.C~ bedrooms.
Disapproved.
Conditional approval for
bedrooms, with the following stipulations:
Additional Comments
By:
The Municipality of Anchorage Department of Health and Human Services (DHHS) issues Health Authority
Approval Certificates based only upon the representations given in paragraph 5 above by an independent
professional engineer registered in the State of Alaska. The DHHS does this as a courtesy to purchasers of homes
and their lending institutions in order to satisfy certain federal and state requirements. Employees of DHHS do not
conduct inspections or analyze data before a certificate is issued. The Municipality of Anchorage is not
responsible for errors or omissions in the professional engineer's work.
Municipality of Anchorage ~UG 1 Z 1996 _
OE.^RmENT OF & SE.V,CES RECEiVE W .
Environmental Services Division
825"L' Street, Room 502 · Ancflomge, Alaska 99501 · (907) 343-4744
Health Authority Approval Checklist
A. WEll. DATA
Log pr'-~cnt (Y/N) ~/ Date complctecl
ToUd dcptb ~,/.,~ / '
Cazd ~ ~'/$
Samta~., seal (Y/N) }/'
If A. B. or C. n-ach ADEC lea. er. ADEC ~ter ~. stem number
Cas~g hcigl~ (above gn:.md)
Wim~ properly protected (Y/N)
FROM WELL LOG
AT INSPECTION
WATER SAMPLE RESULTS:
Coliform
Date of ~mple:
B. SEPTIC/HOLDING TANK DATA
Nitrate
Date i~-'------~ Tank size Nmnber of Compamnents -- Cleanouls (Y/N).__
Foundation clcanom (Y/N)~~:~~~ High water .i~rm (Y/N)
Date of Pumping Pumper ~
ABSOR3~i'iON ~ DATA
Dam installed ~ °/2 ° ~;~ Soil ralmg (g.p.d./fl: or ~) /. Z
L~ ~' W~ ~' O~l ~ ~1~ pi~
Eff~ ~fion ~ ~~Mo~tofing ~ p~t(Y~ .
s.,~-~ ~,~ ~ ~'
over field (Y/N) /1/`/
Date of adequacy le~ ~ Results (Pass/Fail) For bedrooms
Fluid dcpth in ab~o~)tion ficki before I~ (t-~---.~ {m~,q}~t~ly after gal. water addcd (in.):
Fluid dcpth (ira.) Minutes later: ~= g.p.d.
Peroxid~ tmatmcat (past 12 months) (Y/N) If yin, gix~ date ~
D. LIFF STATION
High water alarm level al* ~'/fe/''
Cycles tested ~
"Pump on" level at* ,~/~,~" 'Pump off' levcl al*
E. SEPARATION DISTANCES
SEPARATION DISTANCES FROM WELL ON LOT TO:
SepticJholdmg lank on lot ,4//~ : On adjacoul lots
Absorption field on lot /~9 / -4- : On adjacent lots
Pnblic sewer main /~9 ~- Public sewer manhole/cleanoul
Sewer/septic s~rvi¢~ linc ~' ~ '~ Lift station
SEPARATION DISTANCES FROM SEPTIC/HOLDING TANK ON LOT
Building foundation Id '~ Pmp~r~, line /~ · '~ Absorption field /~2 '-,~
Water main/service line ~ ,' Surface water/drninnge/~g9 ·4. Wells on adjacem lots
SEPARATION DISTANCE FROM ABSORPTION FIELD ON LOT TO:
Braiding foundation t/d~ ¥' Wate~ mnlnls~fvi~ line ~.~ ' 4,
Surfa~ water /49d ' +
Curtain diain"i'/
ENGINEER'S CERTIFICATION
Drip. pad ng/ ,ebicle storage area
Wells on adja~.-nu lots /~**)~ *~ PIro{:]~y linc
I certif, v that I have determined thrufield inspections and review,
in conformance with MOA 1~4A guidelines in effect on this date.
Signature
Engineer's Name
Date
Date of Payment
Receipt Number
Re,.,. 8195 OSS: haa.wk.doc
NORTHERN TESTING LABORATORIES, INC.
3330 INDUSTRIAL AVENUE FAIRBANKS. ALASKA 99701 (907) 456-3116 · FAX 456-3125
8005 SCHOON STREET ANCHORAGE. ALASKA 99518 (907) 349-1000 ,, FAX 349-1016
KND Engineering
20441 Ptarmigan Blvd.
Eagle River, AK 99577
Report Dates 07/13/96
Date Arrived~ 07/11/96
Date Sampled{ 07/11/96
Time Sampled{ 1300
Collected By{ KND
Attn{ Ken or Dee
Our Lab #~ A145951
Location/Project{ Eagle Crest Subdivision
Your Sample ID{ Lot 38 Block B
Sample Matrix= Water
Lab
Number Method Parameter
Units
** Definitions **
B = Present in Blank
NA = Not AnaXyzed
E - Estimated Value
= Matrix Interference
D = Lost to Dilution
MDL = Method Detection Limit
Date Date
Result * MDL Prepared Analyzed
A145551 EPA 353.3 Nitrate-N
mg/L
0.33 0.10 07/12/96
Reported By~ Anthony J. Lange
Chemistry Supervisor
~GRE? ~,ANCHORAGE AREA BOP
Department of Environmental Quality
3330 C Street
Anchorage, Alaska 99503
INSPECTION REPORT ON-SITE SEWAGE DISPOSAL SYSTEM
"AMEJ' ~' ~al[/ MAILING ADDRESS ,,~m t~lf VI'~{C -Dv;~-~. PHONE
SEPTIC TANK:
DISTANCE
FROM WELL
INSIDE LENGTH
MA. UF^CTU.E.'<J" ' f MATER,ALF , j NUM.EROF
COMPARTMENTS
INSIDE WIDTH .LIQUID DEPTH I IQUID CAPACITY l'~ ~'O GALLONS.
SEEPAGE I:~T:~-,,-*e~C*,l ' ~* ~ I D~'~''c,-~r-,
NUMBER OF PITS I DIAM~ER ~1 O" WIDTH~ , L[N~T.~.
LINING MATERIAL t~ CRIB SIZE: DIAMETER~DEPTH ~ DISTANCE FROM:
BUILDING FOUNDATION ~* NEAREST LOT LINE JOt TOTAL EFFECTIVE
WEL~
ABSORPTION AREA (WALL AREA)
ADDITIONAL ABSORPTION
BUILDING NEAREST NEAREST
FOUNDATION LOT LINE SEWER LINE
CESSPOOL OTHER SOURCES
APPROVED DISAPPROVED REMARKS
DEPTH DISTANCE FROM:
SEPTIC SEEPAGE
TANK __ SYSTEM
DISTANCES:
INSTALLED BY:
PIPE MATERIAL:
LOT SLOPE:
REMARKS:
DIAGRAM OF SYSTEM
Fo~m NO, EQ-031
G'A'A~//
O ~ E GEOTECHNICAL 8' DEVELOPMENT CO.
Box 90, Davis St., Eagle River, Alaska 99577
694-2774 or 688-2280
Russell Oyster Earl EII/s
694-2774 688-2280
Soils ~ Foundations Land Development
SOIL LOG
Depth (feet)
Sol] ~heracterf~Uc~
0
.1
2
3
4
5
6
7
g
10
11
12
Ground Water Encountered: Yes
Proposed Installation: Seepage Pit
Comments: ~ ,~
Performed by:
No / If yes, what depth
Drain Field ~
FOSS DRILLING
1336 InEra Street
Anchorage, Alaska 99~01
USE OF
WELL OWNER
LOCATION
s~zE oF CA~N~°'DE~H OF ROL,,~.~,~. CA~DTO~
FEET OF DRAWDOWN.
REMARKS
DATE COMPLETED_~./~,~.L.~:~"' _PUMP TO BE SET AT
tO___.
tO
tO
tO__
tO
tO__
to.____
MUNICIPALITY OF ANCHORAGE
DEPARTMENT OF HEALTH & ENVIRONMENTAL PROTECTION
825 L B~lm - Andtm~e. Aim~ ~9501
ENVIRONMENTAL ENGINEERING DIVISION
Telephone 264-4720
REQUEST FOR APPROVAL OF INDIVIDUAL WATER AND SEWER FACILITIES
/t A [. .
p~~n (10~for procelllng.
'-- C~' I PHONE
~ I PHONE
I
BUYER · PHONE
iM~.I (.lNG AODRES~
LEN~D~O INSTITUTION. ., PHONE
TY, T
~TREET LOCA'TION
'~:} SINGLE FAMILY
[] MULTIPLE FAMILY
7. WATE~UPPLY
INDIVIDUAL*
[] COMMUNITY
[] PUBLIC UTILITY
8. ~EWAGE DISIN)~AL SYSTEM
NUMBER OF BEDROOMS
I--1 One [] Four
[] Two [] Five
[~) Three [] Six
~ INDIVIDUAL/ON-SITE'*
[] PUBLIC UTILITY
[] Other
· ATTACH WELL LOG. A well log is required for all wells drilled
since June 1B75. For wells drilled prior to that date, give well
depth (attach log if available.)
'*if individual/on-site, give imtallation dam/]~df .~4/-./~',~a
If system is over two (2) years old an adequacy tm is required
by this Department.
NOTE: THE INSPECTION FEE MUST ACCOMPANY EACH REQUEST BEFORE PROCESSINi
72-01013/78I
CAN BE INITIATED,
~_. ,' THIS SIDE FOR OFFICIAL USE ONL ,.~~~.
DATE RECEIVED
INSPECTION APPOINTMENTS
I TIME TIME TIME
DATE DATE DATE
INSPECTOR INSPECT 0 R INSPECTOR
DIRECTIONS:
1. TYPE OF RESIDENCE NUMBER OF BEDROOM~
[] SINGLE FAMILY i--I ONE [] THREE [] FIVE [] OTHER
[] MULTIPLE FAMILY [] TWO [] FOUR I-'l SIX
2. WATER SUPPLY PERMIT NUMBER
[] INDIVIDUAL DEPTH OF WELL
[] COMMUNITY
DATE DRILLED
[] PUBLIC UTILITY
Connection Verified LOG RECEIVED
3, SEWAGE DISPOSAL SYSTEM PERMIT NUMBER
[] INDIVIDUAL/ON -SITE DATE INSTALLED
[] PUBLIC UTI LITY Z.//
Connection Verified
INSTALLER
~6'~'ptic Tank or []Holding Tank
Size: ~,~:) IfTank ishomemade SOILS RATING
give dimensions:
TYPE OF TANK MANUFACTURER
TOTAL A~SORPTION AREA MATERIAL
4. DISTANCES WELL T0: SePt jc/Hold~Ta n k ] Ab~orplion Area ?.~..~. ~:.~
5. COMMENTS --
~ APPRO~R "~ BEDROOMS
r-'l CO .N~I~.I~L APP~-'OOVAL (letter must~eccompany certificate)
[] DISAPPROVED
DATE BY (~J~)
LEGAL DESCRIPTION
72-010 (Rev. 3/78) ¢,
MUNICIPAUTY OF ANCHORAGE 0
DEPARTMENT OF HEALTH & HUMAN SERVICES
DIVISION OF ENVIRONMENTAL SERVICES
CERTIFICATE OF INSPECTION FOR HEALTH AUTHORITY APPROVAL
OF ON-SITE SEWER AND WATER FACILITY
264-4744
Application Date
GENERAL INFORMATION (MUST BE COMPLETED PRIOR TO SUBMITTAL)
(a) Legal Description (include lot, block, subdivision, section, township, range)
Location (address or directions)
(b) Prope~ Owner ~1~ ~A~ Telephone: Home
Mailing Address
(c) Lending Institution Telephone
Mailing Address
Business
(d) Real Estate Company and Agent
Address
Telephone
(e)
Mail the HAA to the followino address: or: Check here I~.if hold for pick up.
List contact person and day phone number below.
TYPE OF RESIDENCE
Single-Family
Number of Bedrooms
WATER SUPPLY
Individual Well~ Communit7
Public
Note: If community well system, must have written confirmation from the State Department of Environmental Conservation
attesting to the legality and status.
SEWAGE DISPOSAL
Onsite'~ Public r-I Community [:] Holding Tank I'"l
Note: If community well system, must have written confirmation from the State Department of Environmental Conservation
attesting to the legality and status.
Page I of 2 72-025 trey 8,8~1 F~'ont
ENGINEERING FIRM PROVIDING INSPECTIONS, TESTS, FILE SEARCH, DATA AND INFORMATION
As certified by my seal affixed hereto and as of the validation date shown below, I verify that my investigation of this Health
Authority Approval shows that the on-site water supply and/or wastewater disposal system is safe, functional and adequate
for the number of bedrooms and type of structure indicated herein. I further verify that based on the information obtained
from the Municipality of Anchorage files and from my investigation and inspection, the on-site water supply and/or
wastewater disposal system is in compliance with all Municipal and State codes, ordinances, and regulations in effect on
the date of this inspection.
Name of Firm 'J~":~ ,, t~'~ ~ ,Do/'i'~ Telephone
Address '"Z/Z. ~. O ~' ~' ~,-"rH
Date ~J i4 I ~'f ~
Approved for ~' bedrooms by _ _ ~ Date
Approved ~ Disapproved Conditional
Terms of Condit!onal ApproVal
1-21-80
CAUTION
The Municipality of Anchorage Department of Health and Human Services (DHHS) issues Health Authority Approval
certificates based only upon the representations given in paragraph 5 above by an independent professional engineer
registered in the State of Alaska. The DHHS does this as a courtesy to purchasers of homes and their lending institutions in
order to satisfy certain federal and state requirements. Employees of DHHS do not conduct inspections or analyze data
before a certificate is issued. The Municipality of Anchorage is not responsible for errors or omissions in the professional
engineer's work.
Page 2 of 2 72.025 rRev 8/86~ Back
MUNICLP~.LITY OF ANCHORAGE (MOA)
· ~ .kHan._ ,.'~.'c~l~rHOl~iTY APPROVAL (HAA)
~&5~C~?gt-~] ~"~...,,tC~.$ ~-')~'KLIST - FEBRUARY 19~
~O~~ ~ 2~744 .
," ~ 9 :~ Legal Description: . ~ ~, ~
Well Classification ~ ~ ~ If A, B, C. D.E.C. Approve~ (Y/N)
Well Log Present (Y/N) ~ Date Completed ' ~&/~E Yield ~
Total Depth ~t~1 Cased to ~l~J Depth of Grouting
Static Water Level ~/ Pump Set At
Casing Height Above Ground ~nita~ ~al on Casing (Y/N)
Electrical Wiring in Conduit (Y/N) ' ~ Depression Around Wellhead (Y/N)
~peration Distances from Well: :
To Septic/Holding Tank on Lot ~ ; On Adjoining Lo~ ~/~OI
To Nearest Edge of Absorption Field on Lot ~ ~ -' ~; On Adjoining Lots ~ }
To Nearest Public Sewer Line ~1~o ~ To Nearest Public ~wer
CleanouVManhole ~ I ~ ~ To Nearest ~wer Se~ice Line on Lot ~O
Water Sample Collected by ~ ~5 ; Date ~/~ 7
Water Sample Test Results
~mments ~ ~ ~ ~ ~ ~P~ ~ ~ ~F~
B. SEPTIC/HOLDINGTANK DATA
Date Installed
Standpipes (Y/N) '}/~'~ Air-tight Caps (Y/N)
Depression over Tank (Y/N) ~Uo
Pumping/Maintenance Contract on File (Y/N)
Holding Tank High-Water Alarm (Y/N)
Separation Distances from Septic/Holding Tank:
To Water-Supply Well ¢~:~
To Properly Line -f' ~O
To Water Main/Service Line 4. '7"~ I
Course -/' J 5'0
Size I'?..~O ~AL No. of Compartments
Foundation Cleanout (Y/N)
Date Last Pumped
; for
Temporary Holding Tank Permit (Y/N).
To Building Foundation
To Disposal Field
To Stream, Pond, Lake, or Major Drainage
Comments
Page I of 2
C. ABSORPTION FIELD DATA
Soils Rating in Absorption Strata
Date
Installed
~ UtJ/~/~o ~tJ
Width of Field
Square Feet of Absorption Area
Depression over Field (Y/N)
Results of Last AcJequac~ Test
/~,p~rl~/ Type of System Design
Length of Field
Depth of Field ~
Gravel Bed Thickness ~"
Standpipes Present (Y/N)
Date of Last Adequacy Test
Separation Distance from Absorption Field:
To Water-Supply Well"
To Building Foundation
Lot I'J/A
TO Water Main/Service Line ~ O~
To Stream/Pond/Lake/or Major Drainage Course
To Driveway, Pa;king ,~.,;e~, or Vehicle Storage Area
Comments
To Property Line Jot
To Existing or Abandoned System on
; On Adjoining Lots -t- IOO~
To Cutbank (if present)
,4- I~O~ "
· -PloI
Date Installed
Size in Gallons.
"Pump On" Level at
High Water Alarm Level at
Tested for
Electrical Codes (Y/N)
'comments ' '
,Dimensiohs '
Manhole/Access (Y/N)
"Pump Off" Level at
. Vent (Y/N)
Pumping Cycles during/~dequacy Test, Meets MOA
°' Check Permitted Bedroom Rating Against HAA Request *°
I certify that. J. have checked, verified, or conformed to all MOA and HAA guidelines in effect on the date of this inspection.
Signed {,.~)..~/'},1~ Date J/ad'J~ J ~:~ '
Company "'~J~-~(~P ~ eo'~ MOA No.
Receipt No.
Date of Payment
Amount: $
Page 2 of 2
. umc panryo¥
Anchorage
P.O. B(~"%196650
ANCHORAGE, ALASKA 99519-6650
(907) 343-4200
TONY KNOWLE$,
MAYOR
DEPARTMENT OF HEALTH & HUMAN SERVICES
January 19, 1988
Carey S. Meyer, P.E.
Besse, Epps & Potts
2220 East 88th Avenue
Anchorage, Alaska 99507
Subject: Waiver Request for Lot 3B Tract B Eagle Crest First Add
Waiver Request Number WR88-004
Dear Mr. Meyer:
Your request for waiver of the required separation distance
between a septic tank/absorption trench to a private well has
been approved. The required 100 foot separation from the two
parts of the septic system has been waived to 95 feet and 99
feet respectively.
Since the well water is supplied by a confined aquifer at 206
feet and is cased to this depth, the chances of surface water
contaminating this water bearing aquifer are very small. This
is in agreement with the A.D.E.C. waiver guidelines.
This waiver approval applies to this existing well to septic
system separation only. Any future upgrade to either will
require all separation distances be met or another approval
from this Department.
Sincerely,
Daniel J. Roth
Civil Engineer
On-Site Services
cc: Gus Andress, P.E., Manager
On-Site Services/Water Quality Programs
BESSE, E ' PS &
II
January 18, 1989
Department of Health and
Environmental Protection
825 "L" Street
Anchorage, AK 99501
Re: Variance Request for Lot 5B, Tract B,
Eagle Crest - First Addition
Gentlemen, (D~J"~
This letter is to request a variance for well separation
distances for the above-cited lot._Spec£fically,..the
~h9 lot ara less than 100 leer'from the
~eet and the ~earestport~ of the drainfield.is99.feet.-fro~
the well.'
Both the well and the septic were installed in 1975. Research
of the Health Department files produced a previous approval of
both the well and the septic system at 21~ feet. The single
family house is between the well and the disposal system.
In my professional opinion, in this instance the lesser
separation distances are Justifiable and reasonable. The well
casing extends +1 foot above surrounding ground, and a
sanitary seal is in place. Attached is an as-built plot plan
reflecting the location of the house, well, and septic system
for your review. Please grant this variance request and
Health Authority Approval.
Very truly yours,
Carey S. Meyer, PE
Attachments
ENGINEERING, PLANNING, SURVEYING
9')')0 E. 88th Ave./Anchorage, Alaska 99507/Te/e/3hone 907.,3496451/344-1352
"Ploy/ding a qua/ih/personalized se/v/ce to those Dui/ding Alaska'~ future"..
MUNICIPALITY
~NVI ,ON.,.ENT,IL
RECEIVEO
e,,, I
BES.~E, E~P$ & POTT$
2220 FAST 88 AV~2~U~
AN~,ORAT, E, AK 99507
(907) 349-6451
WAT~-R wwr.r. TEST
[IhNIRONMENTAL $[£VICES DIVI.~ION
1988
l r lvf:n
DR,~t GM.,T.,~qS , G ~ Zl · ~.$ AT,',~ I d METER
177' /~.'oo S.7 ~ /7/
leT' I /P:/O,., E7 57 2Z~
Iq7' i IO:~o f & ~ 370
/77' I t~:vo ~7 $7 ~77 F,~
177' I ~t:/~ z,v 3~ &o~
/ ],y,' I 11:17 .....
I
I
24-'~:-r "-.=ac::':' _~/ ~00 +' Ga!Icns