Loading...
HomeMy WebLinkAboutT12N R3W SEC 15 LT 108TI 2N R3W tion 15 Lot 108 #015-483-08 Municipality or Anchorage ..'0. Development Services Depadment '~J}' l : Bulldi;)g Safely Division On. Site Water and Wastewater Program, 4700 S. Bragaw St. '~ ~' P.O. Box 196650 Anchorage, AK 99519-6650 Page www. cl. anchorage.ek.us (907) 343.7904 ON-SITE WASTEWATER DISPOSAL SYSTEM AND/OR WELL INSPECTION REPORT Permit Number: .,~1~ O::ZO I0 "~ , PIDNumber: /flOe u]. ~,,,.fo,d ! Sa, v6 ~ ~ ABSORPTION FIELD LEGAL DESCRIPTION ~a,~ O. 6 Well: ~ New D Upgrade ~ ~ n TANK SEPARATION DISTANCES D Sepl~ U fielding D S.T.E.P. U Othe. - 153' I~0' ~ 25'+ "'-' ~o_p~ ~57~C ~ ~ BENCHMARK Inspections pe,ormed by:TM Eagle River Loop Ro., NO~s: Devel6pmegt Servlces Department A~proval - ','- '"-":..'- - '"" "*' 7 DEPARTMENT OF HE~_I'H ~ND HUMAN SERVICES ENVIRONMENTAL SERVICES DIVISION P.B. Box 196650 eAncho,"oge, At~lsko, 99519-6650 e Telephone: 343-4744 ON-SITE WASTEWATER DISPOSAL SYSTEM AND/OR WELL INSPECTION REPORT LEGAL LOT 108, SECTION 15, T12N, R3W, S.M. P.I.D. 3 HOUSE N£W 1000 GALLON HDP£ $[PTIC TANK TH#1 109 PAGE 3 OP 5 MuniciDolitv oF .A. nch.q.r'gg.e. DEPARTMENT OF HEALTH AND HUMAN SERVICES ENVIRONMENTAL SERVICES DIVISION p.n Box 196650 OAnchorage, AlaskG 99519-6650® Telephone: 343-4744 ON-SITE WASTEWATER DISPOSAL SYSTEM AND/OR WELL INSPECTION REPORT LEGAL LOT 108, SECTION 15, T12N, RSW, S.M. P.I.D. NO. ST1 ST2 /- 94.6' FINAL GRADE-/ ~,, -,'-/ I 1000 GALLON I~ , ~"~ JPOLYETHYLENEI '~-90.9 FINAL GRADE/ MT1 = 82.1' j A B C ST1 60.5' 42.0' - ST2 65.0' 45.0' - C03=94.7' )EL1 65.5' 47.5' -  )EL2 66.5' 48.5' - rMT 58.0' 42.0' - ~01 59.5' 35.0' - 302 - 43.5' 52.0' ~05 - 44.0' 52.0' CO1 =90.8' C03=91.2' .. ~..... ~ ..~0 .Al ~ASKA ~VATER & WASTEWATER .... , ........... ' .... CONSULTANTS, INC. ~ ................ ~'*-~.~--,~- ...... ' '.-, ~-. ~-'~ ~,-',~,,~'-.,,,',~,-,~--,.' ~.-- ' ....... ~ ~?~ ~""'I [SOIL LOG - PERCO~TION ~EST[ ~'"':' ~?~[,;..4....:....~ LK~ DE$CRI~ON: LOT 108; TI~N~ E~, SE~ON ~5 "")l~g o~o~,cs IT[ST HOLE ~1I. ,, , sH TO SOIL C~SSI~CATIONS ~ GP HL s~c ..... SW HH DEPTH TO GROUNDWATER DATE ~ o ~y o/~/~ s~ P~ , ' ' l'ml00' 11 DATE READING CLOCK NET TIHE WATER LEVEL NET DROP  TIHE (HINUTES) READING (INCHES) ~2 / SM ~/=Vo~ ~ .:~o- 6- - .... 4 12:20 ~ -- 30 4-~/2' ~-1/2' ~ttJt~ 14~[~]~ ..... ~ ...... 12:20 6 12:50 1716~ _ ~ __"'- 18 PERCOI ATI~ RATE 20 (HIN,/INCH) PERC. H~E DIA. 6 (INCHES) t9 TEST R~ BETWEEN 7.5 FT. AND 8.O FT, 20 A FC~ HO~ P~SO~ WAS PERFORMED: ~ YES ~ NO SOILS LOGGED BY: JODY MAUS P[RC~ATIOH TEST PERFUMED COMMENTS: PERFORMED BT ~W.W.C.. INC. I, JEFFR~ ~ ~N~S. CERTI~ T~T THIS W~ ~E~FORMED IN ACC0RD~CE WITH A~ ~ATE AND MUNICIP~ GUID~IN~ IN E~LCT 0N ~IS DATE: DEPTH TO GROUNDWATER DATE DRY 12/20/01 ~ - ,~/.~f~ ~L/6 eDed ' ' gO-£L-qad · gC.~t !0~C gCC Z06 ~uo3 aa3e~a~seu pue da~eM easei¥ :XB 3uas MUNICIPALITY OF ANCHORAGE Development Services Department On-Site Water & Wastewater Program 4700 South Bragaw Street P.O. Box 196650, Anchorage, AK 99519-6650 (907) 343-7904 ON-SITE WASTEWATER DISPOSAL SYSTEM PERMIT Upgrade Date Issued: May 13, 2002 Expiration Date: May 13, 2003 Permit Number: SW020108 Legal Description: T12N R3W SEC 15 LT 108 Design Engineer: 0003 S & S Engineering Owner Name: James Homer c/o Debbie Jenkins Owner Address: 1400 Benson Blvd., Suite 200 ANCHORAGE , AK 99503- Parcel ID: 015-483-08 Site Address: 010111 HANLEY CIR Lot Size: 32200 SQ. FT. Total Bedrooms: 3 Permit Bedrooms: 3 This permit is for the construction of: [] Disposal Field [] Septic Tank [] Holding Tank [] Privy [] Private Well [] Water Storage All construction must be in accordance with: 1. The attached approved design. 2. Ail requirements specified in Anchorage Municipal Code Chapters 15.55 and 15.65 and the State of Alaska Wastewater Disposal Regulations ( 18AAC72 ) and Drinking Water Regulations ( 18AAC80 ). 3. The engineer must notify DSD at least 2 hours prior to each inspection. Provide notification by calling (907) 343-7904 ( 24 hours ). ( Not required for a Water Supply Pen'nit only ). 4. From October 15 to April 15, a subsurface soil absorption system under construction during freezing weather must be either: A. Open and closed on the same day. B. Covered, sealed, and heated to prevent freezing. 5.'.'The following special provisions. ?. ENGINEER SHALL SUBMIT ALL AS-BUILT DATA REL~V~ENT TO THE ABSORPTION TRENCH AND THE SOILS TEST WHEN THE INSPECTOIN REPORT IS SUBMI'I-rED TO THIS OFFICE. Municipality of Anchorage Development Services Department Building Safety Division On-Site Water and Waslewater Program 4700 South Bragaw St. P.O. Box 196650 Anchorage, AK 99519-6650 www.cl.anchorage.ak .us (907) 343-7904 ON-SITE SEWEPJVVELL PERMIT APPLICATION FOR A SINGLI~ FAMILY DWELLI'NG Parcel I.D. O I S--- L/ ~, 3 - o ~ Permit Number SWOZ 0 / 08 Property owner(s) /Jq/,,v~5 ~0r'~er Mailing address (1) Mailing address (2) Legal description (Lot, Block & Sub'd.) L Legal description (Section, Township & Range) Lot Size~~ Acre~ THIS APPLICON IS FOR: Sewer Only Sewer and Well Sewer Upgrade THIS PROPER~ CONTAINS: Hot Tub Swimming Pool Therapy Pool Zip Code Number of Bedrooms Well Only Water Slorage Jacuzzi Water Softening Unit I certify that the above information is correct. I further certify that this application is being made for a Single Family Dwelling and is in accordance with applicable Municipal Codes. S & S ENGINEERING d~f2_~ 17034 £agl. Rlv.r Loep Ro.d No. ~4 F.a~le River, Alaska 99577 (Signature of property owner or authorized agent) Permit Fees: Date of Payment: Receipt Number: (Rev, 12/00) '--/I o / O"Z- O Iq s'g" 'Z- Waiver Fees: Date of Payment: Receipt Number: May9,2002 ROBERT C. COWAN, P.E. CIVIL ENGINEF-R~ (907) 694-297g FAX (907) 694-12f t SO~.tTST smUCTt,~& MUNICIPALITYOFANCHORAGE DevqlopmentServiees Department P.O.'Box 196650 Anchorage, AK 99519 REFERENCE: Lot 108, Section 15, TI2N, R3W, S.M. It is requested that you issue a permit to install a septic tank to serve thc existing three bedroom dwelling on the referenced prope~:ty. ADEC has granted a waiver from the existing trench to the Class 'C' well on Lot 109 as shown on the attached. We do not anticipate any adverse effects on neighboring wells, septic systems, reserve areas or drainage patterns by the installation of the proposed septic system. The construction of this system will not prevent any future development on any of the adjacent properties. If you require additional information, please contact us. Sincerely, Robert C. Cowan, P.E. RCC jj Enclosure t7034 IqO RTH EAGLE RN~R LOOP ~ SUITE 204 · EAGLE RIVER, AJ.A~KA ~9577 I,OT 108, SECTION 15, T12N, R3W, S.M. B.J.J. I R.C.C. I 5-9-02 I , Or ' ~'~;/ ~"~'~ % I ~/~ N , ~/.~ PROPOSED ~ ~ ~ ~ 3 8DRM 1000 GALLON ~ ~ I ~ HOUer SEPTIC TANK ~ ~ ~ ~ ~ ~ t~* ~'~fe~' ~ -I~ ~ I ~ x x ~ / ~ / ~EPTIC ROBERT C. COWAN, P.E. CMl. ENGINEEF~ (907) 694-2979 FAX (907) 694-121t ON-SITE WASTEWATER DISPOSAL SYSTEM CONSTRUCTION PRACTICES and MATERIAL SPECIFICATIONS REFERENCE: Lot 108, Section 15, TI2N, R3W, S.M. May 9, 2002 GENERAL: The scope of this project includes the installation of a new 1000 gallon HDPE septic tank to serve the existing three bedroom residence located on the referenced property. Construction shall be in accordance with the approved site plan and design drawings, Municipal permit with any special provisions or conditions, and all applicable State and Municipal Wastewater Disposal Regulations. The contractor shall be responsible for obtaining any necessary underground utility locates. Unless specifically agreed otherwise, the property owner shall be responsible for final grading areas subsequently depressed from soil settling. Contractors installing xvastewater disposal systems 'must be certified by the Municipal Health Department for system installations. Owners installing their own systems must also receive prior approval from the Municipal Health Department. SEPTIC TANK INSTALLATION: 1. A septic tank is to be constructed by a certified septic tank manufacturer. Construction shall include two 4" cleanouts for pumping access. t7034 IqORTH EAGLE RI~R LOOP a SUITE 204 - EAGLE F~VE R, ALASKA ~9577 Page 2 Lot 108, Section 15, T12N, R3W, S.M. May 9, 2002 2. The septic tank shall be sufficiently bedded to prevent settling or shifting of the tank. All standpipes on the septic tank shall extend a minimum of 12 inches above final grade. 4. Septic tanks installed with less than 4 ft. ofcover shall be insulated. o A foundation cleanout shall be installed one to four feet from the building foundation. In the line between the tank and the leachfield there shall be two adjacent cleanouts (unless an effluent pumping system exists within the septic tank). These cleanouts shall be located on undisturbed soil not more than I0 ft. from the tank. The first cleanout, in line, shall be to clean toward the leachfield. The second cleanout shall be to clean toward the septic tank. Final grading over the septic tank shall be such that a positive slope exists away from the septic tank. MINIMUM MATERIAL SPECIFICATIONS: Any septic tank proposed for installation must be constructed by a Municipal approved septic tank manufacturer. The following pipe materials are approved for use in septic system installations in the Municipality of Anchorage: Type of Pipe Perforated Solid Cast Iron Yes Yes ASTM D3034 (PVC) Yes Yes ASTM F810 (HDPE) Yes No ASTM D2662 (ABS) Yes Yes Use of a type of pipe other than listed above must be approved by the inspecting engineer. Insulation shall be at least 2" thick extruded direct burial polystyrene (Dow Chemical Company Styrofoam HI or equal). Septic tank inlets and outlets shall be fitted with watertight couplings (Caulder, Femco, or equal). Page 3 Lot t08, Section 15, T12N, R3W, 8.M. May 9, 2002 INSPECTIONS: Typically there will be a minimum of two (2) inspections required during the installation of the septic tank. These inspections will occur as follows: The first inspection must be conducted after the septic tank is set in place, but may not be backfilled until after this inspection. 2. The final inspection is to occur upon final grading of the property. The inspecting engineer is to be contacted at least 24 hours prior to the start of construction. If necessary, a pre-construction meeting will take place on-site. The inspecting engineer will not coordinate, direct or control in any way the contractors activities. The owner shall contract with the contractor to perform the work outlined in these specifications and plans and in accordance with the attached M.O.A. permit. Them will be no contractual arrangement existing between the contractor and S & S Engineering. S & S Engineering shall be the owner's representative and will inspect the work as stated above to document the contractors activities. Final acceptance of the contractors work rests with the owner and the M.O.A. S & S Engineering shall have no liability to the owner or to others for acts or omissions of the contractor or any other persons performing work on this project or the failure of the contractor to carry out the work in accordance with these construction documents. S & S Engineering's inspecting engineer will not be responsible for the construction means, methods, techniques, sequence, procedures or the safety precautions incident to this project. CONll~CTOR / INSTALLER DEPT. OF ENVIRONMENTAL CONSERVATION DIVISION OF ENVIRONMENTAL llEALTll DRINKING WATER and WASTEWATER PROGRAM 555 CORDOVA STP, EET ANCIIORAGE, AK 99501 http:l/www.state, ak.usldeclhome/htm TONY KNOWLES, GO VERNOR Telephone: (907) 269-7696 Fax: (907) 269-7650 March 26, 2002 Robert C. Cowan, P.E. S & S Engineering 17034 North Eagle River Loop, Suite 204 Eagle River, Alaska 99577 Subjccl: Separation Distance Waiver Request, Lot 108, Section 15, T. 12 N., R. 3 W., between an Undocumented Wastewaler Disposal System and an existing Class C Public Water System (PWSID Number 218035); Review Dear Mr. Cowan: This is response to 3'our letter received iu tiffs office on March 14, 2002 in which you tile Deparlment to grant a separatioo distance waiver for an undocumented wastewater soil absorption system intended to service a single family home on Lot 108 and an existing Class C public water system source well on Lot 109. I have completed my review of the files on Ibis property and thc infornmtion that you have submitted on this project. As noted in your submittal, the existing soil absorption system was installed without approval from tile Municipality of Anchorage. In addition, it is clear that there is sufficient space to locate tl~e existing soil absorption system outside the 150 foot protective radius of the existing Class C public water system source well. As noted above, based on my review it does appear that tile requested separation distance is justifiable when looking at the soils and geological information provided, llowevcr, the issnance ora separation distance waiver for a soil absorption system that was illegal installed years after the last change in the separation distances along with all the public information that bas been provided is harder to justify. Looking at the waiver request from solely a public health issue, the waiver is justifiable. Therefore, in accordance with State Wastewater Disposal Regnlations [I 8 AAC 72.020], the following waiver is being granted: The separation distance from tile Class C public water system source well located on Lot 109 to the soil absorption system [deep trench] on Lot 108 is waived from 150 feet to 130 feet. Tile above distance was taken from tile st,bmitted infornmtion, lfthe soil absorption system on Lot 108 fails, this waiver becomes invalid and tile soil absorption system will need to be relocated outside tile 150 foot protective radius of the Class C public water syslem localed on Lot Robert C. Cowan Page 2 03/26/02 109. I f it is determined that the existing fiberglass septic tank located on Lot 108 needs to be replaced, Ihe new septic tank will need to be relocated outside the 150 foot protective radius of the Class C public water system source well located on Lot I09. Documentation will need to be provided to this office on which septic tank is in use. This waiver does not imply the granting of any additional authorizations, nor obligate any state, federal, or local regulatory body to grant required authorizations. Thank you for your coordination with this office. Ifyou have any questions, please do not hesitate to contact me. Cc: Jim Cross P.E., MOA Sincerely, Environmental Engineer Municipality Anchorage Development Services D~paHment Building Safety Division On-Site Water and Was~ewa{er Program ,{700 Sou/h Bragaw St. P.O. Box 196650 Anchorage, Al< 995t9-6650 wWW.ci.anchorage.ak. Us (907) 3z}3-7904 CERTIFICATE OF HEALTH AUTHORITY/~PPROVAL FOR A SINGLE FAMILY DWELLING Parcel I.D. GENERAL iNFORMATION ~, ;.,'.... : '<,::'.-.. Complete legardescHptiort-- Lot: Expiration Da[e:. 108; Sec 15; T12N; R314; S.M. Location (st~'address or.directions) 1011{ Hanley Cir., Anchorage Curre.nt..PropeHyowner(s) ;' James ~l'orn~r Dayphone. (808)883-9061 Mailing address. Lending a~h~/ Day phone, Benson Bl~d. Day phone She 200 Anchorage, AK 99503 Mailing address Real Estate Agent n~ ~ Mailing Address . 1/+00 W. Un/ess otherwise'requested, HAA will be held by DSD for plcl~Jp. NUMBER OF BEDROOMS: 3 3. TYPE OF WATER SUPPLY: Individual Well Individual Water Storage Community Class, ~ Well Public Water System TYPE OF WASTEWATER DISPOSAL: Individual On-site Individual, Holding tank Community On-site Public Sewer The Municipality of Anchorage Developmenl Servlces Department (DSD) Issues Certificates of Health Authority Approval (HAA) based only upon the representations given In paragraph 5 by an Independent professional civil engineer registered In the State of Alaska. CertiQcates of Health Authority Approval are required for the transier of title (except between spouses) [or propedies served by a single family on-site waslewaler disposal and/or water s,~pply system. DSD also Issues HAAs upon request to homeowners. Certificates of Heatth Au/horiiy Approval are valid for 90 days from/he date of Issue for propedies served by a private or Class C well and may be reissued with new waler sample results less than 30 days old. (Cedilicates may be reissued for a period of up to one year with valid water samples.) Cedific~ies are valid {'or one year for propedies served by Class A or B wells or e public Water system. The Municipality of Anchorage Is no{ responsible [or errors or omissions In the professional engineer's work. 4. STATEMENT OF INSPECTION By ENGINEER As cerlified by my seal affixed hereto and as of Ihe validation da~e shown below. I verify Ihal my InvesUga(ion, based on procedures outlined In file Health Authority Approval Guldellnes for this application, shows that lhe on-s te water supp y and/or wastewater disposal systerrl Is(ar.e.) safe. functional and adequate for the number of bedrooms and lype of structure indicated hereln. I tudher venfy Iha{ based on the nforma on obta ned from the Municipality of Anchorage files and from my Investigation and Inspection, the on-site water supply and/or wastewater disposal system is(are) In compliance iNith all applicable Municipal and State codes, ordinances. and regulations In effect at the time of Installation. · . o NameofFirm S & S EnRineering Address 17f]3~, w~h ~Cle River Lccp Sic. Engineer's Printed Name Robert Phone 694-297c,:,:) Da,e ;~~ ~ ~ ...... ,, ,~ CE-8801 ~1 '~'' '~ i,C.C.. :~.: .. _ bedrooms, with the following stipulations:. DSD SIGNATURE / Approved for ~ Disapproved. Conditional approval for bedrooms. Additional Comments By: Attachments: HAA Checklist Septic Sys{em Advisory Well Flow Advisory X Maintenance Agreements Supplemental Engineer's Report O~her Original Certificale Date: Municipality of Anchorage Development Services Department Building Safety Division On-SIta Water & Wastewatar Program 4700 SOu~ Bragaw St, P.O. Box 196650 Anchorage, AK ggs1G.6650 www. cLanchomge, ak. us (907) 343-79O4 HEALTH AUTHORITY APPROVAL CHECKLIST LegalDesaipfion:lOT/O~.~$ECrIo~ I-~ TI,).m ~ ~':~ ~,~ ParcellO: OI,f'-¥g'.3'-o~ A. WELL DATA WATER SAMPLE RESULTS: Coliform O .colonies/100 mi. Nlltata ~. ~ c) rog./1. nic: · · Date of sample:3/a ~/o ~ B. SEPTIC/HOI nlNG TANK DATA Tank Type/Matartal ~.,~ ~', (- / T.ank'~tze /DOD gal.. NdmbarofCompartmenta ;2. Data of pumplng ~/4- - 4~¢ ~' Pumper -'~ C.: ADSORPTION FIELD DATA iff. Diner bacteria g.p.m. O colonies/100 mi. Data installed ) q q ~ Soil rating ~r ft2/t~rm) ..O. G Length . NI. 5~ ft. Widt~ ~.,,f" ff. Total depth/'5, Y' ff. Eft. absorption area-/S'5- ~ Monitoring tuba Dam ofadequacy test/3./37/01 ~ Results '~-'dFall).,,o~.~/ Fluid depth in absorption field before ~est t' ~' in. Watar added'"/6 / gal. Elapsed T~me: ~ ,C' min. Final fluid cleptil~:a" in. Absorption rata >= Any rejuvenation treatment (past12 mo.) (y/N & type) /,/a,~¢. ~C*,o,v, Ifyes, glvedata --' 8ystam type Grovel below pipe (~. I ft. Depression over field /e O For. :~ bedrooms New depth~ ~' in. J~ 5"0 g.p.d. High watar alarm (Y/~), /~ O D. LIFT STATION Septic tank/lilt station on lot Absorption field on lot Public sewer main Data installed Size in gallons ManholeJ~s~,.-------~ 'Pump on" level at in. 'Pump off' level et ' water alarm level at Datum --.--.--- Cycles tested Meets alarm & cin=uit requirements? SEPARATION DISTANCES SEPARATIONDISTANCESFROMWELLONLOT TO: ~4,~ *~ ~-~ T Io ~1 On adjacent lots ~ in. Holding tank SEPARATION DISTANCES FROM SEPTIC/HOLDING TANK ON LOT TO: Building foundation "~ 7 Water main ~ lA /0 -t' Wel~s on adjacent lots / 5' .3 SEPARATION DISTANCE FROM ABSORPTION FIELD ON LOT TO: Property line ~,,1. Absorption field. Water service line Surface water Pmpert~ line Water Service line COMMENTS"* Building foundation ~ ~' Surface water ) i) 0 /.-t.- Walls on adjaCent lots / 30 4- Water main ~'//R Oriveway, parldngNehld® storage ~ O ~'~- G. ENGINEER'S CERTIFICATION I certify that I have determined through field inspeclfons end review of Municipal mco~Js that the above systems are in conformance with MOA HAA guidelines in effect on this date. Engineer's Pdnted Name Data HAAFee $ 3 '7 Date of Payment Receipt Number 0 ~ I I -/! Waiver Fee $ Date of Payment Receipt Number CE. 8801 APR-OI-02 04:59PM FROM-CT~E ENVIRONMENTAL SRV 9075615301 T-349 P.02/03 F-308 zTr . CT&E Envimnmenla! Services Inc. CT&£ Ref.~' 102158200 l Client Name ~J~tNam~ ~t]08, S~ I~*~/~ P~nt~D~[~j~ ~/0]~002 13:10 Ol~tSamplelD ~t 10g, ~c.?~ ~1~ ~ Coll~t~Dat~[~ 03~8~2 13:35 Ma~x D~ Wa~ R~e~ed Dat~l~ 03~8~002 ]4:10 O~ By TKhn~a) Di~cfor Nitrn~-N M/crobtolo~F Laborator~ Tcral Col/f0rm .49 0.200 m~/L EPA 300.0 col/lOOmL SMI8 9222B 03/2R/02 03/28/02 SBH l~ g~,dtr Street, Sent By: Alaska Water an0 Wastewater Con; 907 338 3246; Mar-13-02 16:35; Page 2/2 =-' ' ' --"--co--suLr^.TS.,.c.. T,E,W.AT£R SEPTIC ADEQUACY TEST DATA NUMBER OF BEDROOM: . ~ GALLONS PER DAY NEEDED: ~ *SEE//.A.A. SITE VISIT CIIECKLIST* FIELD MEASUREMENTS: TOP OF MT/SUMP TO BOI'TOM: .[ ~ ! (MTI) / (MT2) TOP OF MT/SUMP TO DISTRIBUTION LINE: ~s (MTI) / (MT2) STICK-UP OF MT/SUMP: [5" ,(MTI)/ (MT2) TOP OF MT/SUMP TO LIQUID LEVEL: Itq (MTI) / (MT2) METER NUMBER OF SEPTIC TANK MT/SUMP IHSE (+) I TIME READING GALLONS LIQUID LEVEl L19UID LEVEL FALL(-) ~.. I~{'' i ,~ ~,: PASSED ABSORBED ~'t~"~-J-GALLONs IN MINUTES ( GPD) ~: FAILED o SEE ATTACHED LETTER " -B * Anchorage, Alaah g9504 * Ph: (901) 3,37-6179 * Fax: (907) 338-3246 TONY KNOWLES, GOVERNOR DEPT. OF ENVIRONMENTAL CONSERVATION DIVISION OF ENVIRONMENTAL IIEALTil DRINKING WATER and WASTEWATER PROGRAM 555 CORDOVA STREET ANCIIORAGE, AK 99501 http:l/w~wv.state.ak, us/declhomelhtm Telephone: (907) 269-7696 Fax: (907) 269-7650 February 9, 2002 Jeffery A. Gamess, P.E., M.S. Alaska Water & Wastewater Consultants, Inc. 6901 Debarr Road, Suite 2B Anchorage, Alaska 99504 Subject: Separation Distance Waiver Request, Lot 108, Section 15, T. 12 N., R. 3 W., between an Undocumented Wastewater Disposal System and an existing Class C Public Water System (PWSID Number 218035); Review Dear Mr. Gamess: This is response to your letter received in this office on January 14, 2002 in which you the Department to grant a separation distance waiver for an undocumented wastewater soil absorption system intended to service a single family home on Lot 108 and an existing Class C public water system source well on Lot 109. I have completed my review ofthe files on this property and the information that you have submitted on this project. As noted in your submittal, the existing soil absorption system was installed without approval from the Municipality of Anchorage. In addition, it is clear that there is sufficient space to locate the existing soil absorption system outside the 150 foot protective radius of the existing Class C public water system source well. If the septic tank can be relocated outside the 150 foot protective radius of the Class C public, water system source well, there does not appear to be a p~y~i~al o~h'~i{on~n~ifil r~fi~ofi-wh~ the soil absorption system can not be relocated. The waiver request is denied. Thank you for your coordination with this office, lfyou have any questions, please do not hesitate to contact me. Cc: Jim Cross P.E., MOA Sincerely, , / // Keven K Kleweno, P.E. Environmental Engineer tGRE 'ER ANCHORAGE AREA BOP ' UGH Department of Environmental quality 3330 C Street Anchorage, Alaska 99503 INSPECTION REPORT ON-SITE SEWAGE DISPOSAL SYSTEM NAME ~/~/~///-~ (~/I.{~\/ MAILING ADDRESS /-~-~:' V~I, ~?~ t'~VZ _ PHONE LOCATION ].2~(~"~'/~ I~,./.,,~.~,',:~ // ,~',':)/,.:c ,¢ LEGAL DESCRIPTION lC'? /0~ Y~t~.*,,I , /~ SEPTIC TANK: DISTANCE ~¢'Of~c~:'-~t) ~ NUMBER OF FROM WELt ,'OO ~ t MANUFACTURER ,~1.U.'~¢7 t'(_/~5'~ rc~ MATERIAL /7'~.,,~,,,~-- la,5 _ COMPARTMENTS / -- "'__GALLONS. INSIDE LENGTH INSIDE WIDTH LIQUID DEPTH ' LIQUID CAPACITY /4:~o SEEPAGE PIT: NUMBER OF PITS / DIAMETER LINING MATERIAL ~/P'i~ CRIB SIZE: BUILDING FOUNDATION 'glo OR WIDTH 1.5' /7 // / , LENGTHI., DEPTH DIAMETER¢% ~'DEPTN '~ _ DISTANCE FROM: WELL /~/*c~ / TOTAL EFFECTIVE ' ~6-V 9 NEAREST LOT LINE ~( ¢/~ ABSORPTION AREA (WALL. AREA) .... SQ. FT. ADDITIONAL ABSORPTION WELL: .{ ~,/'o/:,~ ,.5 ~: ~> TYPE ~'/k*/~) ~ V, BUILDING FOUNDATION CESSPOOL APPROVED _CONSTRUCTION . DEPTH NEAREST NEAREST SEPTIC LOT LINE SEWER LINE TANK OTHER SOURCES DISAPPROVED __ REMARKS DISTANCF FROM: SEEPAGE SYSTEM DISTANCES: INSTALLED BY: t~¢(~I-I(/-UU~- PIPE MATERIAL: (~-/~1 i,SC>A) ~ LOT SLOPE: REMARKS: -/_1( :f i/J DIAGRAM OF SYSTEM APPROVED J~-~-l.c L~ (" //~?,~i?'~A*C.~.,'-' G,A.A,B, Form No, EQ-031 NAME LOCATION _ SEPTIC TANK: DISTANCE FROM WELl GRE ,,cR ANCHORAGE AREA BOk-.uGH i~ :-,~ Department of Environmental Ouality %~' 3330 C Street A n c h o r a g ,~e~-~]~-'~'~'-- -"'"~....~.~ -i~pE~CTioN REP~=~!~TE~EWA GI~ DISPOS A[~YSTE ~~ ~ INSIDE LENGTH_ INSIDE WIDTH LIQUID DEPTH LIQUID CAPACITY ___ GALLONS. TILE [:)RAIN FIELD: DISTANCE FROM WELL FOUN[ NUMBER OF LINES _ A DEPT~h TOP OF TILE TO ~]ISH GRADE TG~[~ L LENGTH I-ION NEAREST LOT LINE BJLi~E E~ ¢~'~ ~0' ~ ,ZE~~'I~~¢' ' TOTAL EFFECTIVE WELL: TYPE BUILDING NEARESr FOUNDATION __, LO] LINE CESSPOOL _ APPROVED ~__ DISAPPROVED CONST RUCTION OEP Fid NEAREST SEPTIC SEEPAGE SEWER LINE TANK OTHER SOD RCES REMARKS DISTANCE FROM: DISTANCES: INSTALLED BY: SEWER LINE DEPTH: PIPE MATERIAL: LOT SLOPE: RI-MARKS: :)F-- SYSTEM DATE/~/_~ A~'~ROVED G,A.A.B. Forrn EQ 032 GREATER ANCHORAGE AREA BOROUGH DEPARTMENT OF ENVIRONMENTAL QUALITY 3330 "C" STREET ANCHORAGE, ALASKA 99503 TEL, EPHGNE 274-456! PERMIT NO._ SEWAGE DISPOSAL SYS'rEM -- APPLICATION AND PERMIT TYPE AND SIZE Of FACILITY TO BE SERVED FINANCED THROUGH__ SOIL TEST RESULTS · DRAIN FIELD --, OTHER NOTE= THIS PERMIT IS NOT VALID WITHOUT ~OIL TE~T OO""I- T,ON FINAL INSPECTION: 24 HOUR NOT~CE REQUIRED, BACKFILLING OF ANY SYSTEM WITHOUT FINAL INSPECTION BY THE DEPARTMENT OF ENVIRONMENTAL QUALITY AUTHORITY Will BE SUBJECT TO PROSECUTION. MINIMUM DISTANCES, REQUIREMENTS / FOUNDATION TO SEPTIC TANK ~ , DRAIN FIELD ., DRAIN FIELD WELL TO SEPTIC TANI( /(}(~ , SEEPAGE PIT /0 0 DRAIN FIELD ____ , ALSO CONS[DER AREA WELLS. WATER MAIN TO SEPTIC TANK /0 , SEEPAGE PIT DRAIN FIELD CAST [RON INTO AND OUT OF SEPTIC TANK AND INTO CRIB CROSSING GAP OF EXCAVATION 5 FEET INTO UNDISTURBED SOil. GRAVEL BACKFILL CONFORM TO BOROUGH REGULATIONS REGARDIf~G INSTALLATION. DIAGRAM OF SYSTEM OR LICENSED I3ESIGNER I CERTIFY TSAT I AM FAMILIAR W]TH THE REQUIREMENTS OF (~REATER ANCHORAGE AREA B,O~OUGH ORJDINANCE NO. 28-68 AND ']'HAT THE ABOVE ~ ANCHORAGE, Performed For Legal Des c ri p~Li~-n: Lot This Form Reports Soils Log - Soil Test Must Be Logged To 4' Depth Feet lO-- 11--- 12-- 1 3-- GREATER ANCIIORAGE AREA BOROUGII DEPARTMENT OF ENVIRONMENTAl. QUALITY 3330 "C" Street Case # ALASKA 99503 Dated Performe Percolation Test Below Proposed Seepage System Soil Characteristics Was Ground Water Encountered? If Yes, At What Depth? Reading Date Gross Time Percolation Rate MinLite Proposed Installation: Seepage Depth of Inlet COMMENTS: Net Time Depth to H20 Net Dro Pit Drain Eield Depth to Bottom of--Pit or Trench Test Performed BY .... [)ate Certified BY: Da te: L P TED~II~II~ 'NJ'AL P,~Or:Cl'ION DEPARTMENT OF HEALTH & ENVIRONMENTA RG ' -  825 L Street-Anchorage, Alaska 99S01 AU G ENVIRONMENTAL ENGINEERING DIVISION RE~UEgT FOR APPROVAL OF INDIVIDUAL WATEB AND 8EWEB FAOlLITIES DIRECTIONS: C. omolete ali r)arts on page 1, Incomplat~ requests will not be processed. Please aflow ten I IS) davs for orocesslng, I PHONE 1, PROPERTY OWNER WAILING ADDR PRO ~ DENT (If different from above) BUYER PHONE ~1 LIN~ ADDRESS 3, LENDING INSTITUTION MAILI qG ADDRESS ~, REALTOR/AGENT PHONE J_PHONE .~. q ~, MAILING ADDRESS ~ LE~,'~ DESCRIPTION ....... ~REET LOCATION MBER OF BEDROOMS 6. TYPE OF RESIDENCE ~)' Cue ~] tour '~_x SINGLE FAMIL. Y [] Two ~] Five [] MULTIPLE FAMILY ~,-~ I~, Three ~] Six 7. WATER SUPPLY INDIVIDUAL* [] COMMUNITY PUBLIC UTI LITY Other ATTACH WELL LOG. A well log is required for all wells drilled since June 1975, Cot wells drilled prior to that date, give well depth (attach lei if available,) S. SEWAGE DISPOSAL SYSTEM ~-? ~ ~NDIVIDLJAL, ON-SITE'* *' ~ individual/on-site, give instal etlon date / If system is over two [2) years old an aaequacv test is required [] PUBLIC UTIIJTY o¥ this Department. NOT E: THE INSPECTION FEE MUST ACCOMPANY EACH REQUEST BEFORE PROCESSING CAN BE INITIATED, THIS SIDE FOR OFFICIAL USE ONL', DATE RECEIVED INSPECTION APPOINTMENTS TIME TIME TIME DATE DATE DATE INSPECTOR INSPECTOR INSPECTOR DIRECTIONS: 1, TYPE OF RESIDENCE NUMBER OF BEDROOMS [] SINGLE FAMILY [] ONE [] THREE [] FIVE [] OTHER [] MULTIPLE FAMILY [] TWO [] FOUR [] SIX 2, WATER SUPPLY PERMIT NUMBER [] INDIVIDUAL DEPTH OF WELL [] COMMUNITY DATE DRILLED [] PUBLIC UTILITY Connection Verified LOG RECEIVED 3, SEWAGE DISPOSAL SYSTEM PERMIT NUMSER E~]INDIVIDUAL/ON -SITE DATE INSTALLED []PUBLIC UTILITY Connection Verified - INSTALLER E~Septic Tank or [] Holding Tank Size: If Tank is homemade SOILS RATING give dimensions: TYPE OF TANK MANUFACTURER TOTAL ABSORPTION AREA MATERIAL 4, DISTANCESwELL TO: Septic/HoldingTank Absorption Area Sewer Line Nearest Lot Line Absorption Area to noarest Lot Line 5, COMMENTS ~ROVED FOR ~ BEDROOMS [] CONDITIONAL APPROVAL (letter must accompany certificate) [] DISAPPROVED ,/~ DATE LEGAL DESCRIPTION - 72-010 (Rev, 3/78) Aug~lst 9, 1979 R&M No. 951263 Wayne Viertel Star Route A 1731 M Anchorage, Alaska 99507 Re: Adequacy Test on Existing Sanitary Sewer ~ystem Lot 108~ Sec 15, T12N, R3W, Seward Meridian, Anchorage, Alaska Dear Mr. Viertel: Per your request of August 6, 1979, we conducted a test of the sanitary sewer system on the above described property. The septic tank was pumped prior to the performance of the test on the seepage ]pit. During the test the liquid level in the seepage pit was measured before and after the addition of 1,000 gallons of water. Ali. liquid levels were measured below the top of the standpipe and are shown in the following table: Initial Water Second 24 hour Total Reading Added Reading Reading Drop (gallons) 6.3' 1~OO0 4.9' 6.3' 1.4' The water level rose 16.8 inches with the addit:Lon of 1,000 gallons of water, indicating a capacity of 59.5 gallons per linch. Twenty-four hours later the liquid level was again measured and found to be 6.3 feet. It had dropped 1.4 feet or 16.8 inches. This :indicates an average effluent acceptance rate of 1,000 gallons per day for the surrounding soils. If the three bedroom residence on the property is to house six people, the average load on the system can be expected to be 450 gallons per day. We can therefore conclude that the system is disposing of effluent at an adequate rate for a three bedroom residence. We appreciate this opportunity to be of service to you. Please contact us if you have any questions regarding this letter or if we can be of additional service to you. Very truly yours, R&M CONSULTANTS, INC. Ernest R. Rahaim Staff Geologist Smith Proj eMt Manager ERR:GS/rm/AT&SI-L 3330 "C" Street, Anchorage, Alaska GREATER ANCHORAGE AREA BOROUGH ~.~,~, Department of Environmental Quality [}(L~ 99503 274-4561 Date Received 'rime of Inspection Date of Inspection REQUEST FOR APPROVAl_ OF INDIVIDUAL SEWER & WATER FACILITIES FOR 1. Approval requested Mailing Address: 2. Property Owner: Mailing Address: ,_~..~a~,,~]o 3. Legal Description: ~ 5. Type of facility to be i~spected 6. Well Data: A. Type ~~,e,~ B. Depth C. Construction 7. Sewage Disposal System: D. Bacterial Analysis A. Installed C. Septic Tank: D. Seepage Pit: E. Disposal Field: B. Installer 1. Size .~,.~il . 2. Manufactur~ 1. Absorption Area~,~,~l ~Aterial Total length of lines 8. Distances: A. Well to: Septic tank ., Absorption area _, Sewer Lines __. Nearest 'lot line Other contamination B. F'oundation to septic tank , Absorption area C. Absorption area to nearest lot line EQ-034 (1/74) Page 1 of two pages 3330 /7 · Department of Envirorn~ient~l Quali~y "C" St., Anchorage, Alaska 99503 274-4561 REQUEST FOR APPROVAL OF INDIVIDUAL SEWER & WATER FACILITIES 1. Type of Inspection: 2. Property Owner: Mailing Address: 3. Name of Buyer: CMRO David Cuddy SRA Box 1731M VA x FHA CONV Anchorage, Alaska Jim S. Horner 99507 Da.y Phone 272-5491 Mailing Address: 8117 Spt:Lng Street Day Phone 344-3423 4. Name of Lending Institution: First National Bank of Anchorage Mailing Address: P.o. Box 720, Anchorage, AK. Phone279-4481 5. Name of Realtor or Agent: None Mailing Address: Phone Legal Description: Lot 108, Sec. 15, T12N~ R3W, SM Location: O'Ma~!ey Road & Lipscome St. NHN Pacer Place 7. Type of Facility to 8. Water Supply Type of Supply: be inspected: Single Public Utility No. Bdrms. Individual x Public Utility date of installation served I ndi vi dual (on-site) If Individual, number of dwellings presently If Individual, depth of well Sewage Disposal'System Type of S~stem: If Individual, X page 2 of two pages - Re~ ; for Approval of Indivii 'ai -~ ! &, Wkte, r Facilit~e,s k~gai Description ~] ~,,, ~ ,~ _ Approval ,Valid for one year from date signed Greater Anchorage Area Borough, Department of Environmental Quality DIAGRAM OF SYSTEM certify that the information contained in this request for approval to be a true and accurate representation of the subject sewer and water facilities and these facilities are operating satisfactorilY. ' SIGNED Date EQ-034 (1/74) 333O /C"O r~ bF. NFER AHCHORAGE ARLi, BOROL Departmenk of Environmei;tal Quality "C" St., Anchorage, Alaska 99503 274-4561 REQUEST FOR APPROVAL OF INDIVIDUAL SEWER & WINTER FACILITIES IL) - ~214 -' ]..3 1. Type of Inspection: CMP, O VA x Fill\ CONV 2. Property Owner: David Cuddy Mailing Address: SRA Box 173].H Da~. Phone 272-5491 Anchorage, Alaska 99507 3. Name of Buyer: Jim S. Horner 14ailing Address: 81].7 Spring street D__~ Phone 344-3423 4. Name of Lending Institution: First National Bank of Anchorage Mailing Address: P.o. Box 720, Anchorage, AK. Pholle279-4481' 5. Name of Realtor or Agent: None Mailing Address: Phone 6. Legal Description: Lot 108, Se(:. 15, T12N, R3W, Sbl Location: O'Ma]ley Road & Lipscome St. NIIN Pacer PJace 7. Type of Facility to be inspected: Single 8. Water Supply Type of Supply: Public ULility Individual If Individual, number of dwellings presently served If Individual, depth of well Sewage Disposal. System Type .of S~/s~;eril: Public Utility If Individual, date of installation No. Bdrms. 2 individual (on-site) X