Loading...
HomeMy WebLinkAboutNORTH SLOPE #1 BLK 3 LT 6North Slope Block 3 Lot 6 #050-511-13 Municipality of Anchorage s a„ Development Services Department Building Safety Division ; On-Site Water & Wastewater Program, 4700 South Bragaw St. P.O. Box 196650 Anchorage, AK 99519-6650 www.ci.anchorage.ak.us (907) 343-7904 Page 1 of 3 On-Site Wastewater Disposal System and/or Well Inspection Report Permit Number: SW020178 PID Number: 050-511-13 "OTBP MASON WEST c/o RANEY HARDMAN w/ REMAX OF E.R. Wastewater System: ❑ New ■ Upgrade Y P9 Address: 16600 CENTERFIELD DRIVE * EAGLE RIVER, AK 99577 ABSORPTION FIELD Phone: No. of Bedrooms: (907) 440-7257 3 t7 Deep Trench ■Shallow Trench ❑ Bed ❑Mound ■other LEGAL DESCRIPTION Soil Raft: 5.0 Total Depth from original grade: SEE DWG. opD/sq. pt, Ft Block: Lot: Subdivision: Depth to pipe bottom from original grade: Gravel depth beneath pipe: 3 6 NORTH SLOPE #1 SEE DWG. pt. 0.61 rc Township: Range: Section: Flu added above original grade: Crural leno: - - - SEE DWG. FL 40 It WELL: ❑ New ❑ Upgrade Growl wklth: 5 Number d It. 1 Dist. between Krum: — Ft. It close aeon (Private, A.B,C): Total Caved To: Total aIworptlo. ane: Total Pipe material: Ft so, a D 3034/ F-810 Driller. Dote Drilled: Static Water Lwel: bwtaller. Dab hiatal • CCC CONSTRUCTION 6%21-25/2002 Yield:Pump Set At:casing Height Above Ground: TANK GPM rL Ft SEPARATION DISTANCES ❑Septic 13Holding ❑S.T.E.P. ■Other* To Septic Absorrppttion Lift Holding Public/Frivolo Manufacturer. ANCHORAGE TANK Capacity In gallons: 1500 From Tank Fiend Station Tank sewer Lin« Well 100'+ 100'+ — — 25'+ Material: FIBERGLASS Number of eomperimente: 2 Surface water 100'+ 100'+ — — — LIFT STATION Lot line 5'+ 10'+ - - - Size in gallon: Monufacbrer: 1500 ANCHORAGE TANK ORENCO SYSTEMS 5'+ 10'+ - - - mp on a I" L• ump Neal at Nigh water alarm atFoundation TIMER TIMER 45" Pump Nab Modal: Elaekloal Inepaclfone performed by: Curtain Drain NONE KNOW 0' #20 OSI 05 HHFJ M.O.A. Remarks. —, SEPTIC TANK ABANDONED BENCH MARK Location and artaDescription: PER UPC. TOP OF MANHOLE *THIS IS AN ADVANTEX TREATMENT UNIT Auumed El vatiom 106.19 FL ENGINEER'S SEAL QOO �OO V AKWWC, INC. Inspections performed by: Dates: 1st 6/21/2002 ... - :... 2nd 6/23/2002 3rd 6/24/2002 ess.. 0 Development Services Departme Ap 0�9, ' •. E 7953 . roval ,fop �44pe Reviewed and approved by: Date:-/- (Rev. 12/01) D o�O pr o� QO ofeS Sia n t c 40po�d PERMIT NUMBER: AS—BUILT DRAWING ING PARCEL ID NUMBER: SW020178 050-511-13 EXISTING DRAINFIELDS USED AS A RESERVE INSTALLED FLOW DMRTER ° NEW 1500 GALLON ADVANTEX TREATMENT SYSTEM v -. CO2 NEW DRAINFIELD a ` Ta \ a A -e. B C ST1 — 51.44 32.80 ST2 — 53.11 37.25 POD — 51.47 34.25 MH — 52.93 37.72 FD — 54.60 38.82 C01 48.44 28.39 — MT1 47.24 26.81 — CO2 24.44 36.37 — MT2 26.26 36.51 — INSTALLED FLOW DMRTER ° NEW 1500 GALLON ADVANTEX TREATMENT SYSTEM v -. CO2 NEW DRAINFIELD a ` Ta \ a DRAWN BY: ALASKA WATER & WASTEWATER SCALE'C.J.G. CONSULTANTS, INC. 1„ = 40, :... ... .... ... c'.... ... 6901 DEBARR ROAD, SUITE 26 - ANCHORAGE, AX 99504 . PHONE (907)337-6179 • FAX (907),338-3246 PREPARED FOR: MASON WEST - PHONE NUMBER: PAGE NUMBER: c/o RANEY HARDMAN w/ REMAX OF E.R.(907) 440-7257 2 OF 3 1f GO LEGAL DESCRIPTION: QA• ' , 7 53 m�G NORTH SLOPE SUBDIVISION #1; LOT 6, BLOCK 3, TYPE OF WORK: vQea'orofessio��\oma AS—BUILT DRAWING OF SEPTIC SYSTEM UPGRADE 4OQQ��Opd6 i DRAWN BY: ALASKA WATER & WASTEWATER SCALE'C.J.G. CONSULTANTS, INC. 1„ = 40, :... ... .... ... c'.... ... 6901 DEBARR ROAD, SUITE 26 - ANCHORAGE, AX 99504 . PHONE (907)337-6179 • FAX (907),338-3246 PREPARED FOR: MASON WEST - PHONE NUMBER: PAGE NUMBER: c/o RANEY HARDMAN w/ REMAX OF E.R.(907) 440-7257 2 OF 3 1f GO LEGAL DESCRIPTION: QA• ' , 7 53 m�G NORTH SLOPE SUBDIVISION #1; LOT 6, BLOCK 3, TYPE OF WORK: vQea'orofessio��\oma AS—BUILT DRAWING OF SEPTIC SYSTEM UPGRADE 4OQQ��Opd6 PERMIT NUMBER: PARCEL ID NUMBER:SW020178AS-BUILT DRAWING 050-511-13 FINAL =105A TOP OF TAP = 100.66 INVERT OF P = 99.60 FINAL GRADE _ 98.15 +/— MT CO FILTER TOP OF 94.41NJ �'r. _ .�,_� I INVERT OF PIPE (AVG.) OF 10LE 16.19 OP OF TANK = 100.62 BOTTOM OF I -EXCAVATED TO A MAXIMUM DEPTH ATION 0 HIGHEST OF 6" BELOW BOTTOM OF LINT = o9 94 NATURAL ORGANIC SOIL LAYER. 6/25/2002 DRAWN BY: ALASKA WATER & WASTEWATER SCALE C.J.G. CONSULTANTS, INC. •M- --- _�. - 6QR DEBARR ROAD, SUITE 28 - ANCHORAGE. AK 99504 - PHONE (907)337-609 - FAX (907)338-3246 N.T.S. PREPARED FOR: MASON WEST PHONE NUMBER: PAGE NUMBER: c/o RANEY HARDMAN w/ REMAX OF E.R.(907) 440-7257 3 OF 3 LEGAL DESCRIPTION: NORTH SLOPE SUBDIVISION #1; LOT 6, BLOCK 3, TYPE OF WORK: PROFILE AS—BUILT DRAWING OF SEPTIC SYSTEM UPGRADE w mailil1118m® 0 fes 5l0n' �00poo�` JUN -27-2002 THU 09;43 AN CCC,CONSTRUCTION 907 696 3274 P. 02 8895 L6 13 3K,_ - STATE, ZIP KE pjMCAVYFORV"REWRM Olen mr9wo W20 Sent By: RE/MAX OF EAGLE RIVER, INC.; 9076960214; May -30-02 12:18PM; Page 212 2557221656 V*ON WEST JR PAGE 82 . ... .... wq. : 51.44 32.15 -.-T t3:1 -i ..q 44 *k.gil .37.72 '.'i ... . .... 54:8Q: 3.8�x' .48. 44 28.39 .--.UTj 4714 26.8 ' "24'-44� . 316.37'J.,' - 36.5i .%W ........ . . . . . . . . . Ilk . . . . . . . . . . . . . . . . . .... .k....... : 51.44 32.15 -.-T t3:1 -i ..q *k.gil .37.72 f.'a 7- 54:8Q: 3.8�x' .48. 44 28.39 .--.UTj 4714 26.8 ' "24'-44� . 316.37'J.,' - 36.5i P 3MIN ..q era& �ji .%W Ilk P 3MIN 0 MUNICIPALITY OF ANCHORAGE Development Services Department On -Site Water & Wastewater Program 4700 South Bragaw Street P.O. Box 196650, Anchorage, AK 99519-6650 (907) 343-7904 ON-SITE WASTEWATER DISPOSAL SYSTEM PERMIT Upgrade Date Issued: Jun 19, 2002 Expiration Date: Jun 19, 2003 Permit Number: SW020178 Parcel ID: 050-511-13 Legal Description: NORTH SLOPE #1 BLK 3 LT 6 Design Engineer: 0041 AK Water & Wastewater Consultarr Site Address: 030828 KUPARUK AVE Owner Name: Mason West C/O Raney Hardman of Rer Lot Size: 43260 SQ. FT. Owner Address: 16600 Centerfield Dr. Total Bedrooms: 3 Permit Bedrooms: 3 Eagle River, AK 99577 - This permit is for the construction of: ❑✓ Disposal Field ❑✓ Septic Tank ❑ Holding Tank ❑ Privy ❑ Private Well ❑ Water Storage All construction must be in accordance with: 1. The attached approved design. 2. All requirements specified in Anchorage Municipal Code Chapters 15.55 and 15.65 and the State of Alaska Wastewater Disposal Regulations ( 18AAC72 ) and Drinking Water Regulations ( 18AAC80 ). 3, The engineer must notify DSD at least 2 hours prior to each inspection. Provide notification by calling (907) 343-7904 ( 24 hours ). ( Not required for a Water Supply Permit only ). 4. From October 15 to April 15, a subsurface soil absorption system under construction during freezing weather must be either: A. Open and closed on the same day. B. Covered, sealed, and heated to prevent freezing. Received By: Issued By: Date: Date: / 02 Municipality of Anchorage Development Services Department Building Safety Division On -Site Water & Wastewater Program 4700 South Bragaw St. P.O. Box 196650 Anchorage, AK 99519-6650 www.ci.anchofage.ak.us (907)343-7904 CA/ ON-SITE SEWER/WELL PERMIT APPLICATION FOR A SINGLE FAMILY DWELLING Parcell.D. 050-511-13 Permit Number 51,✓020/79 Property owner(s) MASON WEST Day phone 440-7257 Mailing address (1) c/o RANEY HARDMAN w/ REMAX OF E.R. Mailing address (2) 16600 CENTERFIELD DRIVE * EAGLE RIVER. AK Zip Code 99577 Legal description (Lot, Block & Sub'd.) LOT 6. BLOCK 3: NORTH SLOPE SUBDIVISION #1 Legal description (Section, Township & Range) N/A Lot Size Acres Sq.Ft. Number of Bedrooms 3 THIS APPLICATION IS FOR: Sewer Only ❑ Well Only ❑ Sewer and Well ❑ Water Storage ❑ Sewer Upgrade 0 THIS PROPERTY CONTAINS: Hot Tub ❑ Jacuzzi ❑ Swimming Pool ❑ Water Softening Unit ❑ Therapy Pool ❑ I certify that the above information is correct. I further certify that this application is being made for a Single Family Dwelling and is in accordance with applicable Municipal codes. ALASKA WATER & WASTEWATER CONSULTANTS, INC. Permit Fees: 400 4 1-50 i 'r:� f ) Date of Payment: 6 — l n — () 2 Waiver Fees: Date of Payment: Receipt Number: (1) 2 I Lf 'Z 9A Receipt Number: ALASKA WATER & WASTEWATER CONSULTANTS, INC. June 17, 2002 Municipality of Anchorage Development Service Department Building Safety Division On -Site Water & Wastewater Program 4700 South Bragaw Street P.O. Box 196650 Anchorage, AK 99519-6650 Ref: Proposed Septic Upgrade for Lot 6, Block 3; North Slope Subdivision #1 ADYANTEXTm TREATMENT SYSTEM To whom it may concern: 1. GENERAL: The existing 3 bedroom home is served by a private well and septic system. The existing septic system consist of a 1000 gallon septic tank and three 5 -wide type drainfields. The drainfields are in a state of failure and a septic upgrade is needed for the sale of the house. A test hole was excavated southeast of the existing septic system. We are proposing to design the septic system around the 30 foot radius of this test hole. Due to the shallow groundwater, the limited amount of receiving soils, and the steep slopes, we are proposing to use an Advantex treatment system and a 5 -wide trench type drainfield. Comments regarding the design are as follows: 2. SOILS: See the attached log, which shows the soil classifications, groundwater monitoring, and the percolation test results. 3. DRAINFIELD APPLICATION RATE: The intent is to install an Advantex Treatment System that will allow the use of a small drainfield in the area around the 30 foot radius of the test hole. A percolation test was performed between the depths of 6.0 to 6.5 feet and found the rate to be 13.33 minute/inch. The Advantex system has received class III approval, which allows for an application of 5.0 GPD/FT? Regardless, we are going to conservatively assume an application rate of 3.0 GPD/FT2.. 4. TRENCH DESIGN: a. Percolation Rate: 13.33 minutes/inch b. Allowable Application Rate: 3.0 gallons/day/ftZ c. Number of Bedrooms: 3 d. Design Flow: 450 gallons per day e. Minimum Absorption Area: 150 ftZ 6901 Debarr Road, Suite 2B — Anchorage, AK 99504 — Ph: (907)337-6179 — Fax: (907)338-3246 f. Total Depth: 5.0 feet (maximum — limit excavation to the bottom of the existing fill) g. M.O.A. Approved Sand Filter Depth: 2+ to 3+ feet h. Effective Depth: 0.5 feet i. Width: 5 feet j. Minimum Length: 40 feet long k. Effective absorption area: 200 flZ 5.ORENCO PACKAGE SYSTEM: The STEP tank with the Advantex Treatment System will be manufactured by Anchorage Tank & Welding to meet the latest design criteria established by Orenco Systems, Inc. The point of contact at Anchorage Tank is Lowell McNutt. As with their standard STEP tank, it is equipped with a high water alarm per M.O.A requirements. 6. SURFACE WATER: There is no surface water within 100 feet of the proposed septic system upgrade. 7. TOPOGRAPHY: As can be seen on the attached design, the proposed drainfield is to be installed on a flat bench at the base of a 25+ percent slope. The downhill side of the proposed trench will not exceed a 25 percent slope. 8. CLOSING: I am open to any suggestions from your department that would be an improvement to the proposed system. I am unaware of any negative impacts that this installation would impose on adjacent wells, or septic systems. If you have any questions, please call us at NOTE: Attached is a site plan drawing, a design drawing, an Advantex detail, a trench detail, a soil logs, and a 7 page construction specification letter which are all part of the design package for this septic system. 6901 Debarr Road, Suite 2B— Anchorage, AK 99504 —Ph: (907)337-6179 —Fax: (907)338-3246 LOT 7 NORTH �SLOPEKS/D LAT 6, BLOCK 4• NORTH SLOPE S (/ m� EXISTING SEPTIC SYSTEM LOT 7, BLOCK 3; NORTH SLOPE S/D (5�opv LOT 5, BLOCK 2; NORTH SLOPE S/D SERVED BY A PRIVATE WELL AND SEPTIC SYSTEM NO ENCROACHMENT CONCENRS LOT 5, BLOCK 4; NORTH SLOPE S/D 3 BEDROOM HOUSE LOT 5, BLOCK 3; NORTH SLOPE S/D LOT 6, BLOCK 2; NORTH SLOPE S/D SERVED BY A PRIVATE WELL AND SEPTIC SYSTEM NO ENCROACHMENT CONCERNS LOT 7, BLOCK 2; NORTH SLOPE S/D ALASKA WATER & WASTEWATER SCALE: J'L.M. .% N Q; CONSULTANTS, INC. 1" 100 ?.. 7* 6901 DEBARR ROAD, SUITE 26 - ANCHORAGE, AK 99504' PHONE (907)337-6179' FAX (907)338-3246 REPARED FOR MASON WEST PHONE NUMBER: PAGE NUMBER: /o RANEY HARDMAN w/ REMAX OF E.R. 440-7257 1 OF 4 .n f A. ness: LOT 6, BLOCK 3; NORTH SLOPE SUBDIVISION #1 SITE PLAN FOR PROPOSED SEPTIC UPGRADE 611,02, WELL RADIUS SURVEYOR P. EXISTING DRAINFIELDS TO BE USED AS A RESERVE SITE. SHALL HAVE THE 100 \ ;ED BY A REGISTERED 0 ANY CONSTRUCTION 0 6m.N11:10I9711 STALL FLOW DIVERTER "' -EXISTING SEPTIC TANK TO BE ABANDONED COMPLETELY 0 0 0 0 0 0 0 0 o /p� o 0 0 ` o 0 3 DETAIL 0 DRAINFIELD. EXCAVATE A o 0 5.0 FEET DEEP MAXIMUM BY a i o ~"o 0 o � o 0 0 0 0 0 0 o a ALASKA WATER & WASTEWATER SCALE. CONSULTANTS, IN Cl. 1„ _ 40, ........ ......1......... 6901 DEBARR ROAD, SUITE 2B • ANCHORAGE, AK 99504 - PHONE (907)337-6179 - FAX (907)338-3246 REPAIRED FOR: MASON WEST PHONE NUMBER: PAGE NUMBER: . c/o RANEY HARDMAN w/ REMAX OF E.R. 440-7257 2 OF 4 On e ess.- :GAL DESCRIPTION: Yo 9i E 7953 m LOT 6, BLOCK 3; NORTH SLOPE SUBDIVISION #1 �>1 e� coN 'PE OF WORK:4�adprfessio�0\ o DESIGN OF PROPOSED SEPTIC UPGRADE (ADVANTEX) 44 fes &b7 9%. / ALASKA WATER & WASTEWATER SCALE. CONSULTANTS, IN Cl. 1„ _ 40, ........ ......1......... 6901 DEBARR ROAD, SUITE 2B • ANCHORAGE, AK 99504 - PHONE (907)337-6179 - FAX (907)338-3246 REPAIRED FOR: MASON WEST PHONE NUMBER: PAGE NUMBER: . c/o RANEY HARDMAN w/ REMAX OF E.R. 440-7257 2 OF 4 On e ess.- :GAL DESCRIPTION: Yo 9i E 7953 m LOT 6, BLOCK 3; NORTH SLOPE SUBDIVISION #1 �>1 e� coN 'PE OF WORK:4�adprfessio�0\ o DESIGN OF PROPOSED SEPTIC UPGRADE (ADVANTEX) 44 fes &b7 9%. NOTE: FEET (LAND THE CONTRACTOR SHALL HAVE THE 100 \ FELL RADIUS FLAGGED BY A REGISTERED ` \ SURVEYOR PRIOR TO ANY CONSTRUCTION EXISTING DRANFlELDS TO BE USED AS A RESERVE SnL— \ \ / V \ G neasq her \ essj0��~ FA YI{Y a Y.WIK�GW. — \ TRENCH TWIT N3 SA FEET DEEP MA1(IMUM BY \ 5 FEET WIDE 8Y 40 FEET LONG. ADD 2 TO \ 3 FELT OF M.OA APPROVED SAND FILTER AND THEN 0.5 FEET OF CLEAN, WASH SEWER ED 7F DRNNROCK. THE TRENCH IS TO BE RISTALlED PARALLEL. TO ALL COMW (SEE DETAIL DRAWING, PACE 4 OF 4) 6/13/2002 DRAWN BY: ALASKA WATER & WASTEWATER J•L.M. S CONSULTANTS, INC. 1 = 40r 6901 DESARR ROAD, SUITE 28 • ANCHORAGE AK 99506 • PHONE (907)357-6179 • FAX (901)338-3246 PREPARED FOR: MASON WEST PHONE NUMBER: PAGE NUMBER: c/o RANEY HARDMAN w/ REMAX OF E.R. 440-7257 1 2 OF 4 LEGAL DESCRIPTION: LOT 6. BLOCK 3; NORTH SLOPE SUBDIVISION #1 TYPE OF WORK: DESIGN OF PROPOSED SEPTIC UPGRADE (ADVANTEX) 7; 1 •. 7V ...... ......... A . . . . .. .. ........ esa:• '•. E 7953 .-" a, �nP�ofeeslo^d &b7I9-2- AdvanTex' Treatment S stem Y � � 6 NOTE: JIM CROSS, P.E. HAS THE NOTE: THE BOARD INSULATION TO BE INSTALLED OVER THE SEPTIC TANK 8c 4' AX20- Mode �d o 0 0 ADVANTEX MANUAL BEYOND ON ALL SIDES EXCEPT UNDER THE ADVANTEX FILTER. THIS WILL ALLOW (� n 40x94Pod Owco Systems* '•°""° FOR HEAT TO ESCAPE FROM TANK & RISE TO THE FILTER ABOVE IT. INLET_ FINAL 6' 6" PVC PUMP-OUI (TYP.2, 6' PJC COUPLING GLUED TO TANK (TYP.2) 30 INCH ORENCO INLET BIOTUS BIOTUBE SCREENED VAULT SLIDE SECTION OF 6' PIPE '�"'�'.-`r�•u�':.; OVER THIS CONNECTION 3 BEDROOM - ORENCO TO PROVIDE EFFLUENT SHEER PROTECTION- ADVANTEX PUMP BRIDGE EXXCCAVVATION TANK DATE: 6/13/2002 DRAWN BY: p�•��... �lV� ALASKA WATER & WASTEWATER SCALE: �.L.M' C,,�:.4 CONSULTANTS, INC. N.T.S. * : ... .... ..... ..: 6901 DEBARR ROAD, SUITE 213 . ANCHORAGE. AK 99504' PHONE (907)337-6179' FAX (907)338-3246 PREPARED FOR: MASON WEST PHONE NUMBER: PAGE NUMBER: O c/o RANEY HARDMAN w/ REMAX OF E.R. 440-7257 1 3 OF 4 QO IS Orne S. LEGAL DESCRIPTION: 10 C 79 e�0 LOT 6, BLOCK 3; NORTH SLOPE SUBDIVISION #1 �Mq - TMPE OF WORK: ep DETAIL DRAWING OF FIBERGLASS S.T.E.P. TANK AND ADVANTEX SYSTEM - D' roo�o�600 17 I L--------------------- - - - - - - - - - - - - - - - - - - - - - MONITORING TUBE FEET LONG ORIGNAL GRADE IR4)C11N][IMN FILTER ALASKA WATER & WASTEWATER J. L M. CONSULTANTS, INC. Bim` 6961 DEBARR ROAD, SUITE 28' ANCHORAGE, AK 99504 . PHONE (907)337-6179' FAX (907)338-3246 N.T.S. PREPARED FOR: MASON WEST PHONE NUMBER: PAGE NUMBER: c/o RANEY HARDMAN w/ REMAX OF E.R. 440-7257 4 OF 4 LEGAL DESCRIPNON: LOT 6, BLOCK 3; NORTH SLOPE SUBDIVISION #1 TYPE OF WORK: DETAIL DRAWING OF TRENCH DESIGN GRADE -ORIGINAL GRADE 2+ F SAND N DEPTH TO GROUNDWATER DATE �o�opp 6/5/2002 7'-8" QF.A 7'-8" 6/12/2002 S`40 AKA WATER & WASTEWATER y�00 - 6" pp - CONSULTANTS, INC. p * p ........ ... . ... ..... .......0 ROAD. SURE 2B + ANCHORAGE, AK 89804 + PHONE (907)337-6179 + FAX. (907)338-3245 + WFHBRE ok•wewm 6901 DEBAAR 30 3-1/4" SOIL LOG - PERCOLATION TEST 3 :...� - LEGAL DESCRIPTION: LOT 6, BLOCK 3; NORTH SLOPE SUBDIVISION #1 p., f me s: p PERFORMED FOR: MASON WEST 6/5/2002 QQ9m C 795 Amp 30 3-3/4" DATE: 5 4:12 - ((feet = r ORGANICS ����00000���� 1 TEST HOLE 30 3-3/4" SOIL CLASSIFICATIONS k�pgR 2 FILL MIXED 4 ',to< GW ORG ExlnNG 3 W/ ORGANICS „;w:,:; GP ML srs�TEM �' \ K qV \ E 4 GM E GC OLNrJ 0n °o SW MH 5 • : SP CH I _ SM OH 6 Sc I u SITE PLAN \� 7 1"=100' SM/ML 8 W/ SOME TH 1 \ GRAVEL e - g PROPOSED ' ^ q IXEDRO SEPTIC InNG 3 BEDROOM UPGRADE `` .,et4H0USE 10 11 B.O.H. 12 13 14 5 15- 16 16- 17 17- 18 18— PERCOLATION PERCOLATION RATE 13.33 (MIN./INCH) PERC. HOLE DIA. 6 (INCHES) 19 TEST RUN BETWEEN 6.0 FT. AND 6.5 FT. 20 A FOUR HOUR PRESOAK WAS PERFORMED: E YES ❑ NO SOILS LOGGED BY: JODY MAUS PERCOLATION TEST PERFORMED BY: ZACH GALL COMMENTS: THIS SITE WILL REQUIRE THE USE OF A INNOVATIVE TYPE SEPTIC SYSTEM. PERFORMED BY AKWWC, INC. I, JEFFREY A. GARNESS, CERTIFY THAT THIS AS P RFORMED IN ACCORDANCE WITH ALL STATE AND MUNICIPAL GUIDELINES IN EFFECT ON THIS DATE: � DEPTH TO GROUNDWATER DATE 9' 6/5/2002 7'-8" 6/6/2002 7'-8" 6/12/2002 3:12 - DATE READING CLOCK TIME NET TIME (MINUTES) WATER LEVEL READING NET DROP (INCHES) 2/28/2002 1 3:12 - 6" - 2 3:42 30 3-1/4" 2-3/4" 3 3:42 - 6" - 4 4:12 30 3-3/4" 2-1/4" 5 4:12 - 6" - 6 4:42 30 3-3/4" 2-1/4" Sent By: Alaska Water and Wastewater Can; 907 338 3246; Jul -12-02 11:34; Page 2/3 Municipality of Anchorage Development Services Department • Building Safety Division On -Site Water and Wastewater Program 4700 Bragaw Street s e r r r P.O. Box 196450 Anchorage, AK 99519.6450 www.ci.anchuragc.ak.ns (907) 343.7904 PROPERTY OWNER AGREEMENT FOR THE MAINTENANCE OF AN ON-SITE WASTEWATER DISPOSAL SYSTEM of This agreement, dated 7 9 t l 2— , is made between the Municipality of Anchorage Development Services Department (DSD) and the property owners) of 309;B V E� C11 L_ k C19s Nd'+k Steep_ 1', 3, L..4- ie� --, This agreement 1s made for the purpose of maintaining an on-site wastewater disposal system on the subject property. The property owners agree to the following: Submit to the Municipality of Anchorage, on an annual basis, an inspection and operation statement from a registered professional engineer. This inspection and operation statement shall verify that the engineer has inspected all effluent and air pumps, timers, and alarms, and that any deficiencies have been repaired and that the system is functioning as designed. VVA f howrc.s Iaj Haller-}- Jr. (Printed Name) Ile 'Q\�\1iaon?FAL$ ✓v - d Cal-w'11�G6'^ 1116105 r rT • •'•fie. , a ?;?� • `��P\ OF PSP \ %/lllliill\\\\\ (Signature) (Printed Name) qw MUNICIPALITY OF ANCHORAGE DEPARTMENT OF HEALTH & ENVIRONMENTAL PROTECTION 1*0 ENVIRONMENTAL ENGINEERING DIVISION 825 L Street - Anchorage, Alaska 99501 Telephone 264.4720 ON-SITE SEWAGE DISPOSAL SYSTEM AND/OR WELL INSPECTION REPORT NAME - PHONE EW ❑ UPGRADE MAILING ADDRESS S 1 - C L£ vE'L- p '99s Tl'7 LEGAL DESCRIPTION ID LOCATION NO. OF BEDROOMS -3 DISTANCE TO: : Well Absorption area - Dwelling�j I+ PERMI NO. 95 U b2 S b36 F Manufacturer Material No, of compartmggts v~ai Liq, capacity in gallons I,a�O IF HOMEMADE: Inside length _� Width Liquid depthL OJ O z DISTANCE TO: Well Dwelling PERMIT NO. SZ FQ- Manufacturer 1AMaterial Liquid capacity i —gallons DISTANCE TO: Well r Founda�onO f Nearest lot line PERNyI,TD W e Y�3 Z No. of li es Length pf aachh 1) r , Total length of,lines Trench wid#h_ Distance between link �� �� f..�U inches Top of tile to, finish grade 'P(1..p�t!-, Material beneath tile .. Total effective absorg ion area D I — I S } �.. inches �1� W Length Width pth PERMIT NO. w C7lh uaai a Type of crib Crib diameter ib depth Total effective absorption area to N DISTANCE TO: Well uilding foundation Nearest lot line Class De th Driller Distance to lot line PERMIT NO. J S W � DISTANCE TO: Buil ing foundation Sewer line "Se p tic tank Absor tion area(s) p OTHER PIPE MATERIALS G kscN1 12 sov SOI L TEST RATING 4v+ ` d INSTALLER REMARKS TL�1 % S of-Ai �► +e•.a 3 2 f ''• / Aw F`a sees ase a;+ „+ +A. Robert Shafer v"ao a°•' F. wM APPROVED SRSi96x DATZ2� LEGAL �„hIVER, ALASKA .�/�pvSTT ! s wi:� 0'34-29?$ Pki. 72-013 (Rev. 3/78) b4 4i 20 , 63 13-tk i*'a 0 l F� in' i'F*1"1 T AQft),04 /Qt /.06, WTI % . S0 EMQINEERING SCOTT PEPPERS Ss SRR 194-X EAGLE RIVEf;; AK 99577. T- PHONES 6,- -29'79 =' *SCRIPS SUBDIVISIONG SECTION= 32 TOWNSHIPS 14N RANGE, 1E - $ 43260 (SQ.FT. OR ACRES) D'ROOMB; 3 . beloware.the'options available to you in design ingr your;septid q. Choose the option theat best fits your site. - - - - - - - - - - - - - - - +' 1f PIPE BOTTOM (FT.) 1.5 **. DEPTH: (FT. Y 0.5 )EPTH (FT.) 2.0 WIDTH (FT.? 27.0 s LENGTH (FT.} 54.0 "VOLUME .(CU. YDS.} 54.0 (ZE (GALS) .' 11000.4 4T#NG; M. FT. /BR) 320 "PTH TO PIPE BOTTOM < 2.0 FT. REQUIRES ADDITIONAL GROUND DOVER rPT}� TO PIPE•BOTTOM < 3.5 FT. REQUIRES INSULATION (Pt TO PIPE BOTTOM < 4.0 FT -'MAY REQUIRE A'LLFT STATIOW .' 1N1< MUST HAVE AT LEAST TWO COMPARTMENTS � r-__- -- - - - a fy 'thsfti' d .� Y £f ehi familiar with the requirements for on-sitw_sewere and well0 a c� tAft by the Municipality of Anchorage (MOA).,and the State of ll install the,system in accordance with all MOA cadws etld re wi ;in,rmpliance with the design,triteria of this permit.s adher.6 o aTl-FfOA and State of Alaska requirements far'the`r stances framany euisting well, wastewater disposal system br !Ret a system an: this or any radjacent 'or nearby lot. *0*0*1(,and that this permit:, t is valid a maximum f 3 b litiJCF y en'Ierg'ement will rs4uire an additional permit. .; TA'1 ON IS INSTALLED IN AN _AREA CO.V"ED 8Y MCA )UI0iN�` �f fi 421E; DONE B`Y ^ A I ICON FZi cTn' IC�#3N, - ❑ SOILS LOG MUNICIPALITY OF ANCHORAGE DEPARTMENT OF HEALTH AND ENVIRONMENTAL PROTECTION PERCOLATION 0*1 TEST 825 L. Street, Anchorage, Alaska 99501 2644720 SOILS LOG - PERCOLATION TEST PERFORMED FOR: JG�C�"t*//I� 1 F�2�PE�LS�n \ DATE PERFORMED: LEGAL DESCRIPTION: �yT �.c� I :.7I_..-+� . 7 �V D�L""'�L� Jt--cef, I'RrcOT'( SLOPE SITE PLAN 1 3 A 51"!�� 6 13 14 15 UM - L -O/ e-" 16 y• WAS GROUNDWATER --- Gcross ENCOUNTERED? Depth to Net l�vl IF YES, AT WHAT E DEPTH? �— Water Drop 17- ...... ..p4 gabar2 A. Sherr ` No. 1457,E'r 20 PERFORMED 72-008 (6/79) Reading Date --- Gcross Net Depth to Net Time Time Water Drop ( V 5'-Q< 31X)D A 3 tLvo :D1�P D ILkle s Z Ib PERCOLATION RATE 45-�- (minutes/inch) TEST RUN BETWEEN , FT AND L` FT M-.114 N L j ' \ I �jCISTlt..16� 1bOv(7 m IT i MIT 7Z' ©M r la' UT/L/T E�SEME�T '� . S o s h" IW F11.1' t4 CAAS HUI G ER ANCHORAGE AREA BOR C I RTMENT OF ENVIRONMENTAL QUALI 3500 TUDOR ROAD ANCHORAGE, ALASKA 99507 279-8686 INSPECTION REPORT ON-SITE SEWAGE DISPOSAL SYSTEM T/ I ~.(%If` (/ /1 F/C? - MAILING '�I" NAME T ADDRESS kiCX'l_L/�lJIPHONE� LOCATION%/g/) 6i 611') LEGAL DESCRIPTION SEPTIC TANK: DISTANCE FROM LIQUID CAPACITY 1660 GALLONS. INSIDE SEEPAGE SYSTEM: SEEPAGE PIT: NUMBER OF COMPARTMENTS LIQUID DEPTH. NUMBER OF PITS / OUTSIDE DIAMETER OR WIDTH `� ' LENGTH DEPTH Cc ' LINING MATERIAL`llk'TI't� 1�G"C ,S . DISTANCE FROM WELL , BUILDING FOUNDATION –, NEAREST LOT LINE 1G�ih Z TOTAL EFFECTIVE ABSORPTION AREA (WALL AREA) 4cc✓ SQ. FT. TILE DRAIN FIELD: TOTAL LENGTH DISTANCE FROM WELL FOUNDATION NEAREST LOT LINE OF LINES NUMBER OF LINES DISTANCE BETWEEN LINES TRENCH WIDTH IN. TOTAL EFFECTIVE ABSORPTION AREA SQ. FT. LENGTH OF EACH LINE _ _DEPTH: TOP OF TILE TO FINISH GRADE DEPTH OF FILTER MATERIAL BENEATH TILE IN. ABOVE TILE WELL: /W' DISTANCE FROM WATER TYPEb0-l' � DEPTH—, BUILDING FOUNDATION. - SAMPLE NEAREST S �NEAREST CCTEOTHER SEWER TANK%LOT LINE�G Z1) , SYSTEM CESSPOOL—, SOURCES— DISTANCES: DIAGRAM OF SYSTEM 2LI %/ Z Lr DATE APPRO Vf9� �� '. "'� `"`- r_ A o GRVER ANCHORAGE AREA BOUGH DEPARTMENT OF ENVIRONMENTAL QUALITY PERMIT NO. 4 0 3500 TUDOR ROAD POUCH 6-650 - ANCHORAGE, ALASKA 99502 t 1 TELEPHONE 279-8686 SEWAGE DISPOSAL SYSTEM - APPLICATION AND PERMIT D NAME OF APPLICANT MAILING ADDRESS /AICD HTE INSTALLATION LOCATION�� '•�� ♦ //,`- //•• �• // �+�s� LEGAL DESCRIPTION( INSTALLATION OF: SEPTIC TANK SEEPAGE PIT' 1/ DRAIN FIELD OTHER TYPE AND SIZE OF FACILITY TO BE BE E FINANCED THROUGH T BE INSTALLE SOIL TEST RESULTS O E: THIS PERMIT IS NOT VALID WITHOUT SOIL TEST COMPLETION DATE ANTICIPATED FINAL INSPECTION: 24 HOUR NOTICE REQUIRED. BACKFILLING OF ANY SYSTEM WITHOUT FINAL INSPECTION BY THE HEALTH DEPARTMENT AUTHORITY WILL BE SUBJECT TO PROSECUTION. SEPTIC TANK SIZE T. TYPE MINIMUM DISTANCES, REQUIREMENTS FOUNDATION TO SEPTIC TANK FOUNDATION TO SEEPAGE PIT DRAIN FIELD SEPTIC TANK TO SEEPAGE PIT WALL SEPTIC TANK , SEEPAGE PIT , DRAIN FIELD TO NEAREST LOT LINE. WELL TO SEPTIC TANK DRAIN FIELD WATER MAIN TO SEPTIC TANK DRAIN FIELD SEPTIC TANK, , SEEPAGE PIT TO RIVER, LAKE. STREAM. SEEPAGE AREA SIZE SEEPAGE PIT ALSO CONSIDER AREA WELLS. SEEPAGE PIT DRAIN FIELD CAST IRON INTO AND OUT OF SEPTIC TANK AND INTO CRIB CROSSING GAP OF EXCAVATION 5 FEET INTO UNDISTURBED SOIL. 4 INCH DIAMETER CAST IRON SIPHON PIPES ON SEPTIC TANK AND SEEPAGE PIT FITTED WITH AIRTIGHT REMOVABLE CAPS. GRAVEL BACKFILL CONFORM To BOROUGH REGULATIONS REGARDING INSTALLATION. ge \��� '• ` HEALTH AUTHORITY OR, LICENSED DESIGNER a. TYPE DIAGRAM OF SYSTEM 1 CERTIFY THAT 1 AM FAMILIAR WITH THE REQUIREMENTS OF GREATER ANCHORAGE AREA BOROUGH ORDINANCE NO. 28-68 AND THAT THE ABOVE DESCRIBED SYSTEM IS IN ACCORDANCE WITH SAID CODE. DATE APPLICANT -S SIGNATURE Municipality of Anchorage ' Development Services Department Building Safety Division On -Site Water & Wastewater Program 4700 South Bragaw St. P.O. Box 196650 Anchorage, AK 99519-6650 www.ci.anchorage.ak.us (907)343-7904 CERTIFICATE OF HEALTH AUTHORITY APPROVAL Parcel I.D. 050-511-13 1. GENERAL INFORMATION FOR A SINGLE FAMILY DWELLING HAA# H R 01-2 O 2S Expiration Date: q - 2 -2- 0 --)- Complete legal description NORTH Complete SLOPE SUBDIVISION #1; LOT 6, BLOCK 3, Individual Water Storage ❑ Individual Holding tank Location (site address or directions) 30828 KUPARUK AVENUE * EAGLE RIVER, AK 99577 Current Property owner(s) MASON WEST Day phone Mailing address Lending agency Mailing address Real Estate Agent Mailing address c RANEY HARDMAN w/ REMAX OF E.R. Day phone RANEY HARDMAN w/ REMAX OF F . Day phone 440-7257 16600 CENTERFIELD DRIVE * EAGLE RIVER, AK 99577 Unless otherwise requested, HAA will be held by DSD for pickup. 2. NUMBER OF BEDROOMS: 3 3. TYPE OF WATER SUPPLY: TYPE OF WASTEWATER DISPOSAL: Individual Well i® Individual On-site Individual Water Storage ❑ Individual Holding tank ❑ Community Class Well ❑ Community On-site Public Water System ❑ Public Sewer ❑ The Municipality of Anchorage Development Services Department (DSD) Issues Certificates of Health Authority Approval (HAA) based only upon the representations given in paragraph 4 by an independent professional civil engineer registered in the State of Alaska. Certificates of Health Authority Approval are required for the transfer of title (except between spouses) for properties served by a single-family on-site wastewater disposal and/or water supply system. DSD also issues HAAs upon request to homeowners. Certificates of Health Authority Approval are valid for 90 days from the date of issue for properties served by a private or Class C well and may be reissued with new water samples. (Certificates may be reissued for a period of up to one year with valid water samples.) Certificates are valid for one year for properties served by Class A or B wells or a public water system. The Municipality of Anchorage is not responsible for errors or omissions in the professional engineer's work. Note: Alaska Water and Wastewater Consultants, Inc. shall be paid $4690.00 at, orphor to closing for the engineering services provided. 4. STATEMENT OF INSPECTION BY ENGINEER As certified by my seal affixed hereto and as of the validation date shown below, I verify that my investigation, based on procedures outlined in the Health Authority Approval Guidelines for this application, shows that the on-site water supply and/or wastewater disposal system is(are) safe, functional and adequate for the number of bedrooms and type of structure indicated herein. /further verify that based on the information obtained from the Municipality of Anchorage files and from my investigation and inspection, the on-site water supply and/or wastewater disposal system is(are) in compliance with all applicable Municipal and State codes, ordinances, and regulations in effect at the time of installation. Name of Firm ALASKA WATER & WASTEWATER CONSULTANTS, INC. Phone 337-6179 Address 6901 DEBARR ROAD, SUITE 2B * ANCHORAGE, AK 99504 Engineer's Printed Name JEFFREY A. GARNESS, P.E. Engineer's Comments: In conducting this evaluation, AKWWC, Inc. attempted to provide a thorough, conscientious engineering analysis of the system in accordance with ADEC and MOA DSD Guidelines & Regulations. The reported results described the performance of the system under the conditions encountered at the time of the test, and separation distances measured to readily identifiable features. The operational life of all wells and septic systems depend on the local soils condition, groundwater levels that may fluctuate during the year, and the water usage of the family being served by the system. These conditions are outside the control of the evaluator of the system. Satisfactory test results do not guarantee future performance of the system, nor do they guarantee that there are no hidden defects or encroachments. AWWC, Inc. can therefore not provide any warranty or future estimate of how long the system will continue to meet the operational requirements of the ADEC or MOA DSD. The content of this report is for the sole benefit of the owner listed above. Any reliance upon or use of this report by any other person or party is not authorized, nor will it confer any legal right whatsoever. 5. DSD SIGNATURE V Approved for .7 bedrooms. Disapproved. Conditional approval for bedrooms, with the fllowing stipulations: Attachments: HAA Checklist Manitenance Agreements Septic System Advisory Supplemental Engineer's Reort Well Flow Advisory Other By: � i l �r J c* 't Original Certificate Date: (Rev.1901) V � too fes s�^ OFrC .yO,Ap ON-SITE WATER AND WASTEWATER PROGRAM Al J O�• _ R JJJJ • • • r(\y\. NT S&'1 J)V %-- c-2— (Rev 12)01) -2— Municipality of Anchorage Development Services Department Building Safety Division On -Site Water & Wastewater Program 4700 South Bragaw St. P.O. Box 196650 Anchorage, AK 99519-6650 www.ci.anchorage.ak.us (907)343-7904 HEALTH AUTHORITY APPROVAL CHECKLIST Legal Description: NORTH SLOPE S/D #1; LOT 6, BLOCK 3, Parcel ID: 050-511-13 A. WELL DATA Well type PRIVATE If A, B, or C provide PWSID# N/A Date completed APPROK 1971 Sanitary seal (Y/N) YES Total depth 164+ ft. Cased to 40+ ft, FROM WELL LOG Date of test G Static water level Well production N� —g -p.m. WATER SAMPLE RESULTS: Well Log (Y/N) NO Wires properly protected (Y/N) YES Casing height (above ground) 18 in. AT INSPECTION 5/28/2002 0.68 — g -p.m - Coliform 0 colgnies/100 ml. Nitrate 0.208 mg./L. Other bacteria 0 colonies/100 ml. Arsenic: N/A mg./L. Date of sample: 5/28/2002 Collected by: AKWWC, INC. B. SEPTIC/HOLDING TANK DATA **THIS IS AN ADVANTEX TREATMENT UNIT Tank Type/Material **FIBERGLASS Date installed 6/21-25/2002 Tank size 1500 gal. Number of Compartments E Cleanouts (Y/N) YES Foundation cleanout (YIN) YES Depression over tank (Y/N) YO High water alarm (Y/N) YES Date of pumping NEW Pumper — C. ABSORPTION FIELD DATA Date installed 6/21-25/2002 Soil rating .p.d./ r ft9bdrm) 5_0 System type TRENCH Length 40 Width 5 ft. Gravel below pipe 0.61 ft. Total depth 3.7 ft. Eff. absorption area 200+ ft2 Monitoring tube YES Date of adequacy test NEW Results (Pass/Fail) — Fluid depth in absorption field before test = in. Water added =gal. Elapsed Time: = min. Final fluid depth = in. Any rejuvenation treatment (past 12 mo.) (Y/N & type) Depression over field NO Absorption rate For 3 bedrooms New depth =in. g.p.d. If yes, give date — D. LIFT STATION Date installed 6/21-25/2002 Size in gallons 1500 Manhole/Access (YIN) YES "Pump on" level at TIMERin. "Pump off' level at TIMERin. High water alarm level at 45 in. Datum BOTTOM OF TANK Cycles tested NEW Meets alarm & circuit requirements? YES E. SEPARATION DISTANCES SEPARATION DISTANCES FROM WELL ON LOTTO: Septic tank/lift station on lot 100'+ Absorption field on lot 100'+ Public sewer main On adjacent lots 100'+ On adjacent lots 100'+ Public sewer manhole/cleanout N/A Sewer/septic service line 25'+ Holding tank N/A SEPARATION DISTANCES FROM SEPTIC/HOLDING TANK ON LOT TO: Building foundation 5'+ Property line 5'+ Absorption field 5'+ Water main N/A Water service line 10'+ Surface water 100'+ Wells on adjacent lots 100'+ SEPARATION DISTANCE FROM ABSORPTION FIELD ON LOT TO: Property line *10'+ Building foundation 10'+ Water main N/A Water service line 10'+ Surface water 100'+ Driveway, parking/vehicle storage 10'+ Curtain drain NONE KNOWN Wells on adjacent lots 100'+ F. COMMENTS G. ENGINEER'S CERTIFICATION o`er ''• �'`r�0 i certify that 1 have determined through field inspections and review of Municipal records that the above systems are in """' "' "' " "' • .. conformance with MOA HAA guidelines in effect on this date. OQ ...5.. y Gar . .� Engineer's Printed NaLe- Date JEFFREY A. GARNESS �O� CE 953 4� b2 (o d `o 40@gpro fesaior e\ 910 HAA Fee $ t Waiver Fee $ JO Date of Payment %'26"02- Date of Payment Receipt Number 2-1 sw Receipt Number (Rev. 12/01) Municipality of Anchorage • +� r Development Services Department Building Safety Division On -Site Water and Wastewater Program 4700 Bragaw Street P.O. Box 196650 Anchorage, AK 99519-6650 www.ci.anchorage.ak.us (907)343-7904 Water Well Advisory Health Authority Approval # 020286 During a recent Health Authority Approval on-site inspection and test of the potable water supply well on Block 3, Lot 6 of North Slope #1 subdivision, the well's productivity was determined to be 0.68 gallons per minute. The minimum well productivity required by this Department (AMC 15.55) for a 3 -bedroom residence is 0.31 gallons per minute. Although the subject well currently exceeds this minimum requirement, all parties concerned are advised that the production capacity of the well may fluctuate. Restriction of non-critical water uses such as washing cars and watering lawns and gardens may be required. This advisory must be attached to all copies of the subject Health Authority Approval. ALASKA WATER & WASTEWATER .. .. CONSULTANTS, INC. June 26, 2002 Municipality of Anchorage Development Service Department Building Safety Division On -Site Water & Wastewater Program P.O. Box 196650 Anchorage, Alaska 99519-6650 Ref: Lot Line Waiver for Lot 6, Block 3, North Slope Subdivision #1 To whom it may concern: We request that your department issue a 0 foot lot line waiver from the northwest property line to the old drainfield which will be used as a reserve system. The new drainfield is more than 10 feet from any lot line. I am unaware of any adverse impacts this waiver would have on adjacent wells or septic systems.I, you have any questions, please contact us at 337-6179. Thank you for your assistance. I M.S. 6901 Debarr Road, Suite 2B * Anchorage, AK 99504 Ph: (907) 337-6179 * Fax: (907) 338-3246 * Website: akwwc com Municipality of Anchorage Development Services Department • "i° Building Safety Division On -Site Water and Wastewater Program 4700 Bragaw Street P.O. Box 196650 Anchorage, AK 99519-6650 www.ei.anchorage.ak.us (907)343-7904 Waiver Review Worksheet WR#: R020033 PID#: 050-511-13 HA#: HA020286 Permit#: Date Received: 6/26102 Legal Description: North Slope #1 Block 3 Lot 6 Engineer: Jeffrey A. Garness, PE Alaska Water & Wastewater Cosntultants, Inc. Applicant: Mason West Waiver Requested: 0 feet from the upgrade dainfield site to the lot line Criteria: Geology Points: A. Water Table B. Soil Sorption C. Permeability D. Water Table Gradient E. Horizontal Separation Total: ............. .................... ................... ......... ...... ...........� Waiver is Granted: L__� List Conditions or Reasons for above: Waiver is not Granted., Date: By: ao i ame of Reviewer .......................... NONE ................. ............................ OWNS Rec#: 21889 Amount: $160.00 Date Paid: 6/27/2002 6/27/2002 Municipality of Anchorage George P. 1Ruerch, Mayor Building Safety Division P.O. Box 196650 • 4700 S. Bragaw Street Anchorage, Alaska 99519-6650 • (907) 343-8301 hitp://wunv.ci.anchorzxge.alc.ius Jeffrey A. Garness, P.E. Alaska Water & Wastewater Consultants, Inc. 6901 Debarr Rd. Suite 2B Anchorage, AK 99516 Subject: Waiver Request for North Slope #1 Block 3 Lot 6 Waiver Request #WR020033 Parcel ID 4050-511-13 Dear Mr. Gayness: Your request for a waiver of the required 10 feet horizontal separation from the absorption field to property line has been approved. The approved separation distance is 0.0 feet. This waiver approval applies to the existing absorption field to property line separation only. Any future upgrade to the on-site wastewater disposal system will require all separation distances be met or another approval from this department. If there are any further concerns or questions regarding this waiver, please call our office at 343-7904. Sincerely, Jeffrey:Poet Engineering Technician On -Site Water & Wastewater Program ?. • MUNICIPALITY OF ANCHORAGE DEPARTMENT OF HEALTH AND ENVIRONMENTAL PROTECTION DIVISION OF ENVIRONMENTAL HEALTH CERTIFICATE OF INSPECTION FOR HEALTH AUTHORITY APPROVAL OF ON-SITE SEWER AND WATER FACILITY 264-4720 Application Date Ick 21- 8S' 1. GENERAL INFORMATION (a) Legal Description (include lot, block, subdivision, section, township, range) Location (address or directions) (b) Applicant Name -rrr Fi51,'04Q G Telephone: Home k94 -`a,63" Business S Applicant Address ��' X 1 �`�' � A/ Ill �v,C, 9C1' 1 (c) Applicant is (check one): Lending Institution[]; 8vvrreribuildero; `Buyer ❑ ; Other ❑ (explain); (d) Lending Institution OM WAS Telephone _ Address _ (e) Reai Estate Company and Agent Address Telephone (f) the HAA to the following address: - 2. TYPE OF RESIDENCE Single -Family W Multi -Family ❑ Other Number of Bedrooms 3 3. WATER SUPPLY Individual Well Z Community ❑ Public ❑ Note: If community well system, must have written confirmation from the State Department of Environmental Conservation attesting to the legality and status. _ 4. SEWAGE DISPOSAL Onsite Public ❑ Community ❑ Holding Tank ❑ Note: If community well system, must have written confirmation from the State Department of Environmental Conservation attesting to the legality and status. Page 1 of 2 72-025 n V84] r IR 5. ENGINEERING FIRM PROVIDING INSPECTIONS, TESTS, FILE SEARCH, DA AND INFORMATION As certified by my seal affixed hereto and as of the validation date shown below, i verify that my investigation of this Health Authority Approval shows that the on-site water supply and/or wastewater disposal system is safe, functional and adequate for the number of bedrooms and type of structure indicated herein. I further verify that based on the information obtained from the Municipality of Anchorage files and from my investigation and inspection, the on-site water supply and/or wastewater disposal system is in compliance with all Municipal and State codes, ordinances, and regulations in effect on the date of this inspection. Name of Firm Address Date 6. DHEP APPRO L Approved forfie_, bedrooms Approved / _Disapproved Terms of Conditional Approval Telephone ✓ P' P usa 01 Date 1b---,;,> i-1�6 The Muncipality of Anchorage Department of Health and Environmental Protection (DHEP) issues Health Authority Approval certificates based solely upon the representations given in paragraph 5 above by an independent professional engineer registered in the State of Alaska. The DHEP does this as a courtesy to purchasers of homes and their lending institutions in order to satisfy certain federal and state requirements. Employees of DHEP do not conduct inspections or analyze data before a certificate is issued. The Municipality of Anchorage is not responsible for errors or omissions in the professional engineer's work. Page 2 of 2 72-025 (11/84) A. WELL DATA 3 MUNICIPALITY OF ANCHORAGE (MOOP HEALTH AUTHORITY APPROVAL (HAA) ro, l CHECKLIST - FEBRUARY 1984 264-4720 1: j Legal Descripjion: Well Classification tf�' If A, B, C, D.E.C. Approved (Y/N) , Well Log Present (Yo Date Completed Yield Total Depth i(¢q I Cased to 44t�'+- Depth of Grouting Static Water Level Casing Height Above Ground — Electrical Wiring in ConduitoN Separation Distances from Well: To Septic/UekfirigTank on Lot _ Pump Set At Sanitary Seal on Casing45! N) Depression Around Wellhead (Y/0 r ` ; On Adjoining Lots Lrsot-J- To Nearest Edge of Absorption Field on Lot ; On Adjoining Lots t arC> J ' To Nearest Public Sewer Line rA � To Nearest Public Sewer tf Cleanout/Manhole N To Nearest Sewer Service Line on Lot ZS T Water Sample Collected byS-7�Ct-� ; Date to 23-85 Water Sample Test Results S&-vL-- r1s-f Comments 0►JfAi.�Lo6 �O S86< S 114e- yoe�' Tr> OF S�Prt'1. SEPTIC/HOL YM TANK DATA Date Installed Size T No. of Compartments -4- Standpipes Standpipes (ON) Air -tight CapsQ$aN) Foundation Cleanout(/N) Depression over Tank IWO Date Last Pumped -� Pumping/Maintenance Contract on File (Y/N) a A ; for Holding Tank High -Water Alarm (Y/N) I /�" Temporary Holding Tank Permit (Y/N) Separation Distances from Septic/.ke4drned Tank: To Water -Supply Well _ To Property Line To Water Main/Service, I Course fJ Comments Page 1 of 2 72-026(11/84) 1 To Building Foundation To Disposal Field J L I+ To Stream, Pond, Lake, or Major Drainage 0 0 C. ABSORPTION FIELD DATA Soils Rating in Absorption Strata 47-4 ' 6A' Type of System Design Date Installed 1'-Z-9 - 86 Length of Field 22`5 t Width of Field S Depth of Field 3•S k 2~ til.- CAS yJ N Square Feet of Absorption Area 12� 3� Standpipes Present&N) Depression over Field (Y,10) Dof Last Adequacy Test* Results of Last Adequacy Test r"7: Separation Distance from Absorption Field: To Water -Supply Well ( 5'_ To Property Line ) d' To Building Foundation Ldwr� +� To E*is� Abandoned System on i Lot �� .4- On Adjoining Lots �� I .1' 1 To Water Main/Service Line !J To Cutpank (if present) To Stream/Pond/Lake/or Major Drainage Course To Driveway, Parking Area, or Vehicle Storage Area 3sb Comments D. LIFT STATION Date Installed Size in Gallons Dimensions Manhole/Access (Y/N) "Pump On"Level at Pump Off' Level at High Water Alarm Level at Vent (Y/N) Tested for Pumping Cycles during Adequacy Test. Meets MOA Electrical Codes (Y/N) Comments ** Check Permitted Bedroom Rating Against HAA Request ** I certify that I have checked, verified, or conformed to all MOA and HAA guidelines in effect on the date of this inspection. Signed Date Company MOA No. �SUt�3 Receipt No. a� t, I b Date of Payment 1(U -,a �t -R Amount:$ c Aql=- Page 2 of 2 72-026 (1 1 i84)