Loading...
HomeMy WebLinkAboutNEAR POINT KNOLL BLK 2 LT 13Near Point Knoll Block 2 Lot 13 #041-021-54 Municipality of Anchorage On-Site Water and Wastewater Section • (907) 343-7904 Page 1 of 3 ON-SITE WASTEWATER INSPECTION REPORT Permit Number: OSP201010 PID Number: 041-021-54 Dwelling: ❑■ Single Family (SF) ❑ with ADU ❑ Duplex (D) ❑ Two Single Family Project: ❑ New ❑■ Upgrade Name Mario A. & Mary R. Lanza ABSORPTION FIELD ❑ Deep Trench El Wide Trench El Bed ❑Mound Site Address 6355 Kalmia Circle, Anchorage, AK ❑ Other Phone Number of Bedrooms Soil Rating Total depth from original grade 250-8232 4 EXISTING GPD/SF Ft. LEGAL DESCRIPTION Depth to pipe invert from original grade Ft. Gravel depth beneath pipe Ft. Subdivision Block Lot Near Point Knoll 2 13 Fill added above original grade Ft. Gravel length Ft. Township Range Section Gravel width Ft. Beds: Number of Lines Distance between lines Ft. SEPARATION DISTANCES To Septic Absorption Lift Station Holding Sewer Total absorption area Number of trenches Dist. between trenches From Tank Field Tank Line Ft2 Ft. Well >100' N/A N/A N/A >25 TANK X Septic ❑ S.T.E.P. ❑ Holding ❑ Other Manufacturer Greer Capacity 1250 Gal. Surface Water >100' N/A N/A N/A Material Number of compartments Lot Line >5' N/A N/A N/A NA Plastic 2 Foundation >10' N/A N/A N/A LIFT STATION Manufacturer Capacity RemarksGal. Tank only permit. Alarm location Electrical installed by PIPE MATERIAL House to tank D3034 Tank to drainfield D3034 Installer Northern Excavation Drainfield Existing CO/MT D3034 Inspector J. Mlllette BENCH MARK (Assumed elevation) 100 ft Inspec2ion 151 2/7/20 Location and description dates: n Man door threshold on south wall. 3rd 4 ON-SITE WATER AND WASTEWATER SECTION APPROVAL Engineer's Stamp ' "•'•••:9S �® Conditional Approval: Date ®�AP,..••'°"' � 49th jf O............................................. �� � ;•MICHAEL E. ANDERSON /No. 1&Approved Septic System G7 d_VU&_ 6�Date ,010'••.,, / z/�o/zo •,,.•.'�_�: 0/20 ®! Note: this approval does not include well permit requirements. iF� PROFESS °ePROFES®®®` (Rev ub/U1/18) NEAR POINT KNOLL, BLOCK 2 LOT 13 PERMIT # OSP201010 PID # 041-021-54 � I KALMIA CIR. � LOT 12 / LOT 14 (VACANT) COMMUNITY WATER SERVICE LINE. LOT 13 4-BDRM HOME EXISTING TRENCH TO *EXISTING TANK REMOVED AND REMAIN IN SERVICE.DISPOSED OF PER MOA CODE. NEW 1250 -GAL SEPTIC TANK w/ 20" MANWAY. \ MH \ •sv \ SHED zco I I \ \ � I LOT5 \ �� / \ J' x 30' ANCHOR \ EASEMENT i i / LOT 4C \ \ STUCKAGAIN HEIGHTS BILK A B ENGINEERING GE PLAN AS -BUILT 0 50 100 FEET 1 "=50' MH 37.9 43.2 / SV 1 42.2 1 46.4 2C0 1 44.7 1 48.2/ LEGEND CO - CLEANOUT 2CO - DOUBLE CLEANOUT FCO - FOUNDATION CLEANOUT FS - FLOW SPLITTER VALVE MH - MANHOLE MT - MONITORING TUBE SV - SEPTIC VENT TH - TEST HOLE PROFILE AS-BUILT (NO SCALE) 91.75 86.75 92.35 98.5FCOMH SVPERMIT # OSP201010 PID # 041-021-54 NEAR POINT KNOLL, BLOCK 2 LOT 13 2/12/20 1,250 GALLON SEPTIC TANK 2CO91.55 BUILDING DETAIL SCALE 1 "=20' Rum GASTALDI LAND SURVEYING, LLC JEFF A. GASTALDI, R.L.S. 2000 E. DOWLING RD., SUITE 8 ANCHORAGE, ALASKA 99507 PHONE 248-5454 GRID DATE SW2043 2/19/2020 F.B. JOB NO. 01-08 STUKAGIN STUK132 PLAT NO. 99-78 NEAR POINT KNOLL SUBDIVISION KALMIA LOT 13, BLOCK 2 CIRCLE 110,182 S.F. (2.53 ACRES) I HEREBY CERTIFY THAT I HAVE SURVEYED THE PROPERTY DEPICTED ABOVE AND THAT NO ENCROACHMENTS EXIST EXCEPT AS INDICATED. IT IS THE RESPONSIBILITY OF THE OWNER TO DETERMINE THE EXISTENCE OF ANY EASEMENTS, COVENANTS OR RESTRICTIONS WHICH DO NOT APPEAR ON THE RECORDED SUBDIVISION PLAT. UNDER NO CIRCUMSTANCES SHOULD ANY DATA HEREON BE USED FOR CONSTRUCTION OR FOR ESTABLISHING BOUNDARY OR FENCE LINES. ANCHORAGE RECORDING DISTRICT, ALASKA NOTE: NO CORNERS SET THIS DATE OF A4 • Air CO �! * ; 49TH ... ..................... .00 .. .. .... .......... m ; Jeffery A. Gastoldi : oAV A' a LS -6091 AIF e. v PO' •O..e.e•se 5 Arofessiona\ Lasa a MUNICIPALITY OF ANCHORAGE On -Site Water & Wastewater Prdgram PO Box 196650 4700 ElmofeRoad Anchorage, Alaska 99519'6650 Phone: (907) 343-7904 Fax: (907) 343-7997 http://wwv✓.muni.org/onsite On -Site Wastewater Disposal System Permit Permit Number: OSP201010 Effective Date: Work Type: SepticTank Upgrade Expiration Date: Tax Code Number: 04102154000 Site Legal Address: NEAR POINT KNOLL BLK 2 LT 13 G:2043 Site Mailing Address: 6355 KALMIA CIR, Anchorage Owner: LANZA MARIO A 50% & Design Engineer: FORGE ENGINEERING This permit is for the construction of: ❑ Disposal Field O Septic Tank ❑ Holding Tank, ❑ Privy All construction shall be in accordance with: -2116lz0 Z,�nt S De: j�a rcm�it t 2/512020 2/4/2021 Lot Size in Sq Ft: 110182 Total Bedrooms: 4 Private Well ❑ Water Storage 1, The attached approved design. 2. All requirements specified in Anchorage Municipal code Chapters 15.55 and 15.65 and the State of Alaska Wastewater Disposal Regulations (18AAC72) and Drinking Water Regulations (18AAC80) 3, The wastewater code requires inspections during the installation. The engineer shall notify the Development Services Department per AMC 15.65. Provide notification by calling (907) 343-7904 (24/7), 4. From October 15 to April 15, a subsurface soil absorption system under construction during freezing weather shall be either: a. Opened and Closed on the same day, or b. Covered, sealed, and heated to prevent freezing Received By: Issued By: Date: J )-o Date: MUNICIPALITY OF ANCHORAGE Vil Community Development Department � Phone:907-343-7904 Development Services Division Fax: 907-343-7997 On -Site Water & Wastewater Program ON-SITE SEWER/WELL PERMIT APPLICATION Parcel I.D. 041-021-54 Property owner(s) Mario A. & Mary R. Lanza Day phone 250-8232 �,";I;-- AArnee 11411 Discovery View Dr. Anchorage, AK 99515 Site address 6355 Kalmia Circle Anchorage, AK Legal description (Sub'd., Block & Lot) Near Point Knoll, Block 2, Lot 13 Legal description (Township, Range & Section) Lot Size 110,182 Sq. Ft. Number of Bedrooms 4 APPLICATION IS FOR: APPLICATION IS AN: TYPE OF DWELLING: (® all that apply) ❑ Single Family (SF) Q Absorption Field ❑ Initial (w/wo ADU) Septic Tank ❑X Upgrade Duplex (D) ❑ Holding Tank ❑ Renewal ❑ Multiple Dwellings ❑ Privy ❑ (SF and/or D) Private Well ❑ Water Storage ❑ THIS APPLICATION INCLUDES A VARIANCE / WAIVER REQUESTFOR: Distance: I certify that the above information is correct. I further certify that this is in accordance with applicable Municipal Codes. (Signature of property owner or authorized agent) Permit/Rush Fees:ao�J/- Waiver Fees: Date of Payment: I I a d l a0;2D Date of Payment: Receipt Number: ',;51to6 Receipt Number: Permit No. 5P26 26 1016 Waiver No. Permit App_.;- : . �.�c January 29, 2020 MOA Development Services Dept, On -Site Water & Wastewater Program 4700 Elmore Rd Anchorage, AIC 99507 Subject: Near Point Knoll Block 2 Lot 13 — 6355 Kalmia Cir. Septic system design Dear On -Site Services Enoineer: Wnicipality of Anchorage On-site Water and Wastewater 11 9 •. •o • , OSP201010, Deb Mckenfuss, 02/05! The owner of the above lot has a 4 -bedroom home on the property that is in need of a new septic tank, so we are submitting this permitapplicationforthe constructionof a replacementseptic tank. The attached site plan identifies the locationof the home as well as the septic location. No conflicts exist between this proposed tank location and any other well or septic system, whether on this lot or adjacent lots. The subject lot, in addition to the immediate lots to the north and east, are served by a community well. All wells to the southare greaterthan 100' awayfrom the southproperty lines. The new tank will be a minimum of 100' from all wells and surface water, and more than 10' away from any permanent foundation. Please refer to the attached plan pages for the septic design. If this design is followed, there will be no adverse impacts to adjacent properties. Sincerely, Michael E. Anderson, PE 4gth •: MICHAEL E. ANOERCON s Nc. CE -4381 g�c`�°'•.,,. 1/29/20 �� p ............... \�� �� I � KALMIA CIR. � LOT 12 / ` 1 / ® r nKAAAI IKIITV 1A/ATr=D EXISTING TANK TO BE DECOMMISSIONED IN ACCORDANCE w/ MOA CODE. EXISTING TRENCH TO REMAIN IN SERVICE. OSP201010, Deb Kbckenfuss, LOT 14 (VACANT) INSALL NEW 1250 -GAL SEPTIC TANK w/ 20" MANWAY. \ r- \ \ SHED 2CO J LOT5 i i LOT 4C \ \ / ���P \ & STUCKAGAIN HEIGHTS B L K 2 �p E N G I N E S lI NOTE: NO SLOPES >25% WITHIN 50' OR SURFACE WATER WITHIN 100' OF THE PROPOSED SEPTIC SYSTEM ALL WELLS ON SURROUNDING LOTS WITH IMPACTS TO THIS PROPERTY ARE SHOWN. NO CONFLICTS WITH WELLS OR SEPTIC SYSTEMS. ALL WELLS TO SOUTH ARE >100' FROM PROPERTY LINE 0 50 100 WE ME WE FEET 1"=50' 10'x 30' ANCHOR EASEMENT LEGEND C 0 - C LEANOUT 2C0- DOUBLE CLEANOUT FCO- FOUNDATION CLEANO FS - FLOW SPLITTERVALVE MH - MANHOLE MT - MONITORING TUBE SV - SEPTIC VENT TH - TEST HOLE MunicipalityofAnchorage Page I of Development Services Depadment On-Site Water and Wastewater Program 4700 South Bragaw Street P.O. Box 196650 Anchorage. AK 99519-6650 vnvw.ct.ancflorage.ak.us (907) 343-7904 ON-SITE WASTEWATER DISPOSAL SYSTEM AND/OR WELL INSPECTION REPORT Permit Number: SW0100~ .5¥" PID Number: 041-021-54 "'"'°: Wastewater System: New Spinell Homes 9210 Vanguard D;ive Anch,, AK 99507 ABSORPTION FIELD 344-5678 Four (4) Deep Trench LEGAL DESCRIPTION 1.2 c~e 9 2 13 Near Point Knoll 2 F,. 7 2 .. 41 Well: Class A PWSID No. 218642 3 ~,. 1 N/A A F,. F,.574 ,~ ASTM D3034 PVC ~,. Spinell Homes 6/8/01 *"~: c,,.~ I'~'s'''':F,. i c.~, .,,,,~.o..c.,.~:~, TANK SEPARATION DISTANCES ~ septic r-I Holding 1'"1S.T.E.P. f-I Other:. T~__~o Septic Absorptior Lift Holding ~ublicJPdvate~v.~n~ractu~er. Tank Field Station Tank Se,,e~U~e Anchorage Tank 1,250 w., >200' >200' N/A N/A >25' Steel Two (2) u,u..S~'~ w.,.. >100'>5, >100'>10, N/AN/A N/AN/A V ~... LIFTc~STATION~.~,.~,,,: - NONE ON LOT ,--. >5' >10' N/A N/A /~ .~o~-...,. *,~.~ o.-...,. c~.,.~..- None Noted ~0~.,~ "'"'""': BENCH MARK Garage Slab. 100.0 Engineer's Stamp Inspections performed by: Alan Harala Dates: 1st 6/8/01 · · 49th 2"d 6/8/01 Department of Health and Human Services approval Reviewed and approved by: ~--,--~/./'~, f~Date: 7-/~''0~ Permit Number SW010055 PID No. 041-021-54 Page 2 of 3. \ \ llom~ [1 C4 A B C S1 40.5 37.0 S2 47.1 44.2 C3 59.5 65.1 M1 88.7 74.8 C4 194.9 79.3 ! ! ! ! ! ! ! ! ! ! ! ! l / 1 1 PLAN AS-BUILT SCALE 1" = 60' Municipality of Anchorage DEVEOPMENT SERVICES DEPARTMENT 4700 South Bragaw Street Anchorage, AK. 99519-6655 - 343-7904 On-Site Wastewater Disposal System or Well Inspection Report Permit Number:. SW010082 · ' PID No,: Page 3 of 3 041-021-54 ~ 98.0 ~ u u 91.5 · .-- --, Geo t e x_t~.e Droinl~ietd Rock / 78.0 84 PROFILE AS-BUILT Performed For: Spinell Homes Legal Description: Lot 13 Block 2 Nenr Point Kn~ll Subdsivision SLOPE e~l~O { ~". ~c'~-~ .,.L~,., 825 L Strut. ~ge. ~ 99502~65 ~, ~ .. ....~., SO~LS LOG - PERCO~T~ON TEST ~;' ~?~"t ....... :~ ~ ~ Date Pe¢o~: ~ 1~t SI~ P~ 4 OGIOL GP Silty Gravel with Sand GM Was Groundwater 9 Encountered? If Yes, What Depth? 10 Depth to Water After Monitoring 11 Date: 12 13 14 16 Bottom of Hole 17 18 19 See Site Plan No S L O None P 6/6/01 E Reading Date Gross Net Depth To Net Time Time Water Drop 1 11-May 8:18 4.38' 2 8:31 12 10' 5.62' 3 8:32 4.25' 4 8:44 12 10' 5.75" 5 8:45 4.38' 6 8:57 12 9.94' 5.56' Perc. Rate: 2.5 Min./Inch Perc. Hole Diameter:. 6" Test Run Between 6 Ft. and 7 Ft. Comments: Percolation Cavity Presoaked Prior to Testing. Pedormed By:. AI,AD_HaI:~%. I, Michael E Andemon Certify That This Test Was Pedermed In Accordance With All State and Municipal Guidelines In Effect On This Date: 5114/01 MUNICIPALITY OF ANCHORAGE Development Services Department On-Site Water & Wastewater Program 4700 South Bragaw Street P.O. Box 196650, Anchorage, AK 99519-6650 (907) 343-7904 ON-SITE WASTE1NATER DISPOSAL SYSTEM PERMIT Initial Date Issued: Apr 05, 2001 Expiration Date: Apr 05, 2002 Permit Number: SW010055 Parcel ID: 041-021-54 Legal Description: NEAR POINT KNOLL SUBDIVISION BLOCK 2 LOT 13 Design Engineer: 0014 Anderson Engineering Site Address: NHN KALMIA CIRCLE Owner Name: SPINELL HOMES Lot Size: 110182 SQ. FT. Owner Address: 9210 VANGUARD DRIVE Total Bedrooms: 4 Permit Bedrooms: 4 ANCHORAGE, AK 99507- This permit is for the construction of: [] Disposal Field [] SepticTank [] Holding Tank [] Privy [] Private Well [] Water Storage All construction must be in accordance with: 1. The attached approved design. 2. Ail requirements specified in Anchorage Municipal Code Chapters 15.55 and 15.65 and the State of Alaska Wastewater Disposal Regulations ( 18AAC72 ) and Drinking Water Regulations ( 18AAC80 ). 3. The engineer must notify DSD at least 2 hours prior to each inspection. Provide notification by calling (907) 343-7904 ( 24 hours ). ( Not required for a Water Supply Permit only ). 4. From October 15 to April 15, a subsurface soil absorption system under construction during freezing weather must be either: A. Open and closed on the same day. B. Covered, sealed, and heated to prevent freezing. 5. The following special provisions. AT THE TIME OF CONSTRUCTION THE ENGINEER SHALL PERFORM ADDITIONAL SOIL TESTS IN ACCORDANCE WITH AMC 15.65. Y-- 14--o/ Municipality of Anchorage Development Services Department Building Safety Division On-Site Water and Wastewater Program 4700 South Bragaw St. P.O. Box 196650 Anchorage, AK 99519-6650 www.ci.anchorage.ak.us (907) 343-7904 ON-SITE SEWER/VVELL PERMIT APPLICATION FOR A SINGLE FAMILY DWELLING Parcel I.D. 04.!-02I-5'4 Permit Number Property owner(s) Slflnell Homes Mailing address (1) 9210 Van.quard Drive Anchoraqe, AK 99507 Mailing address (2)~//qN~ .~tiLI'IIA C/RE/.& 7ip Code Legal description (Lot, Block & Sub'd.) Lot t3, Block 2, Near Polnt Knoll Subdivision Legal description (Section, Township & Range) Lot Size 110,182 Acres~"~ Number of Bedrooms Four SF THIS APPLICATION IS FOR: Sewer Only Sewer and Well Sewer Upgrade THIS PROPERTY CONTAINS: Hot Tub Swimming Pool Therapy Pool Day phone 344-5678 [] Well Only Water Storage [--I Jacuzzi [] [] Water Softening Unit [] I certify that the above information is correct. I further certify that this application is being made for a Single Family Dwelling and is in accordance with applicable Municipal Codes. (Signature of property owner or authorized agent) Permit Fees: Date of Payment: Receipt Number: (Rev, 12/00) Waiver Fees: Date of Payment: Receipt Number:. ANDERSON ENGINEERING- P.O, BOX 240773 ANCHORAGE, AK 99524 57.2.7773, 522-6779 (FAX)~ MEMORANDUM DATE: TO: FROM: SUBJECT: April 3, 2001 Dan Roth Mike Anderson, P.E~ Lot 13, Block 2, Near Point Knoll Subdivision Septic System Design and Permit Application We have revised the design of the proposed septic system for Lot 13, Block 2, Near Point Knoll Subdivision to provide 2-5' wide absorption trenches in the lieu of the previously proposed absorption bed. The change was made due to the slopes on the lot which exceed 10% in some cases. The developer of the lot is anxious to obtain a building permit for the lot and needs the septic system permit to do so. He is willing to provide additional soil tests and, if necessary, move the absorption trenches to a more suitable location at a later date. Weather conditions make additional exploration at this time very expensive. We have attempted to site the proposed absorption system near the location of the test hole placed during the initial subdivision of the parent parcel. A site visit yesterday indicates the location of the test hole is fairly fiat as noted on the test hole site plan provided by Hank Wilso.n.., I have also attached a contour map of the area completed during the initial subdivts~on by. Mr. Wilson. The location of the proposed absorption bed appears to meet the requirements of the Municipal Ordinance except that an additional percolation test will be required. We are confident that the soils on this lot are fairly uniform in that they vary from poody graded to well graded gravel. We will furnish additional soils information as required with the as-built of the new system. Thank you for your time concerning this issue and please call if you have additional questions. · ANDERSON ENGINEERING P.O. BOX 24977:3 ANCHORAGE, AK 99524 522-7773 522-6779 (FAX) May 14, 2001 Municipality of Anchorage Building Safety Division On-Site Water and Wastewater Program 4700 S. Bragaw Street Anchorage, AK 99507 Attention: Dan Roth Su~e~: Lot 13, Block 2, Near Point Knoll Subdivision Permit No. SW010055 Dear Dan: The owner of Lot 13, Block 2, Near Point Knoll Subdivision has placed another test hole on a more suitable area of the lot for a septic system. A copy of the test hole log and percolation test is included for your review. This test hole was found to contain silty gravel with some sand which percolated at a rate approximating 2.5 minutes per'inch. No water was found in the test hole and none is expected during the monitoring period. An updated log will be forwarded to you once the 7 day monitoring period is completed. The attached revised site plan shows the location and configuration of the new trench. Based on conditions encountered the new trench will be 40' long by 3' wide with an effective depth of 7'. The owner has also decided to place a concrete slab on the south side of the lot for recreational vehicle parking. This site is also shown on the plan. Please review the attached documentation and revise Permit No. SW010055 to include the new design. Thank you for your cooperation with this modification. Sincerely, Michael E. Anderson, P.E. Attachments Alterna Sit %. -;50 Ga~ )tic T~ Bedroo ~ome % '% .: % TH1 A .% h / CE-4381 _SITE PLAN SCALE 1" = 60' LOT 13, BLOCK 2, NEAR POINT KNOLL SUBDIVISION DESIGN FACTORS: SYSTEM REQUIREMENTS: Four Bedroom Home Perc. Rate: 2-3 MinJlnch Application Rate: 1.2 GPD/SF Deep Trench System 1,250 Gallon Septic Tank 7' Drain Field Rock 4 Bedrooms X 150 GPD 11.2 GPD/SF = 500 SF of Absorption Area 500 SFI14SF/LF = 35.7 LF Trench Length Therefore: Construct an Absorption Trench 40' in Length by 3' Wide With 7' of Drainfield Rock Beneath the Distribution Lateral. Distribution Lateral to Be Placed 3' Below Existing Ground. Total Depth of Trench to Be 10' from Existing Surface. Mound Over Trench if Necessary to Provide Minimum Cover of 3'. · :::3 NOTE: TYPICAL DEEP ,TRENCH SECTION (NO SCALE) Grade Area Over Trench to Drain Away. Minimum 6' Separation From Bedrock. Minimum 10' Separation From Lot Une. Minimum 4' Separation From Groundwater. Minimum 10' Separation From Water Service Line. Maintain 50' Separation From Slope >25%. .Apdl3,2001 Municipality of Ahchorage Development Services Department ' On-Site Water and Wastewater Program 4700 South Bragaw Street Anchorage, AK99519-6650 . . . . Subject: Lot 13,'Block 2, Near Point Knoll Subdivision' · Septic System Design and Permit Application ' ' Impacts to Adjacent Properties - Dear Or'site Services Engineer:. The ~)wner of Lot 13, Block 2, Near Poi'nt K~oll Subdivision intends to place a new four- bedroom home on the lot. We are therefore applying for a permit to construct a new septic system on the lot to serve the' proposed home. The attached Site Plan and backup documentation identify the location and configuration of the new septic system and the parametem, used In the design. It also show. s the location of the alternate site and the water service line proposed for the lot. Ex~sfing drainage pattems are shown and will not be altered by th.e development of the lot. Several test holes we~.e' placed I~ this subdivision over the past years. All of these holes revealed'well to poorly graded gravels with percolation rates between 1 and 5' minutes per inch, A test hole at the proposed location for the new and alternate absorption trenches revealed poorly graded gravel with few fines and a percolation rate of less than-1 minute per inch. No groundwater was noted.in the'test hole dudng 'excavation and none was noted dudng the monitoring period, We are therefore 'proposing to place 2-5'.wide by 6.0.'.long by .5' effective depth absorption trenches with a 2' sand liner to slow the percolat~0n rate and effectively treat the septic effluent. The distribution pipe will be placed at 3' below the existing ground surface and the total depth of the trenches will be 5.5'. 'A minimum of 3' of cover will be placed over the ' bed to pre~/ent frost penetration and possible'freezing. The ground surfa(Je on the lot Slope~ as ~hown on the attached Site Plan. The area'for the new absorption trenches, however,'is fairly'fiat with a'slight grade from south to north. The new trenches will be constructed parallel to the contours of the surface In conformance with Municipal requirements. - Grading Wi!l be acc.omplished to assure surface drainage is away.from the new trenches.. The existing drainage pattern on the lot will not be.affected dunng developme0t. ,. . ., . . : If the system is constructed In accordance With our design the.following statements .apply: . . 1, -The system, If constructed as designed, will have no'adverse Impact on the wells · Lot'13, Block 2,*Near Point Knoll Subdivision' April3,2001 ' - Page Two ' . . ''. ... Michael E. Anderson, P.E. ' Attachments ' · in the area or'those to be constructed In the future. 'The Subdivision is currently served by a community water system. ' The system, if constructed as designed, will have no adverse impact on existing . septic systems in the area or those to be constructed in the future. .. The system, if constructed as designed, will ha~;e no adverse impact on reserve space, either surface or subsurface, on any lots located in the area. The system, if constructed AS designed, will have no adverse Impact on drainage .patterns In the area. The current drainage pattern will be maintained. Sincerely, ' ' 2-61 X rptton % .% TH~)' Alt. ~ Four ;me 250 Gall )tic CE-4381 ' SITE PLAN scALE !" = ~o' LOT 13, BLOCK 2, NEAR POINT KNOLL SUBDIVISION DESIGN FACTORS: SYSTEM REQUIREMENTS: Four Bedroom Home Perc. Rate: <1 MinJInch Application Rate: 1.0 GPD/SF . 2' Sand Liner Required 5' Wide Trench System 1,250 Gallon Septic Tank ,5' Drainfleld Rock 2' Clean Sand (See Spec.) 4 Bedrooms X 150 GPD 1 1.0 GPDISF = 600 SF of Absorption Area 600 SFI5 LF {Width)*1.0 (Red. Factor) = 120 LF Trench Length Therefore: Construct Two 60' Long X 5' Wide X .5' Effective Depth Absorption Trenches. Flowline Elevation In Trenches to be 3.0' Below Original Ground Surface. 2' Sand Liner Required Beneath Dralnfield Rock. Total Depth to be 5.5' Below Existing Ground. Mound Over Trenches to Provide Minimum of 3' of Cover or Provide 2" of Direct BuT Insulation. Zabel Flow Splitter Required to Assure Even Distribution of Effluent From Septic Tank. eSI Natural Backfill 4" PVC Holes Down 2' Sand Liner (See Spec.) prainfield Rock s' NOTE: TYPICAL WIDE TRENCH SECTION (NO SCALE) Grade Area Over Tranch to Drain Away. Minimum 6' Separation From Bedrock. Minimum 10' Separation From Lot Line. Minimum 4' Separation From Groundwater. ' PERPORMED ~OR: Municipalily of Anchorage DEPARTMENT OF HEALTH & HUMAN SERVICES 82.5 'L" Street. Anchorage. Alaska 99502-0650 ' SOILS LOG -- PERCOLATION TEST DESCRIPTION: ,~/~C~p~:),~--~',~ ~,O Y" '/~.~ Townsl~ip. Range. Section: 4 5 6 7 8 9 10 11 12 14 15 16 2O SLOPE I I I SITE PLAN WAS GROUND WATER .~/,'~ ENCOUNTERED? YES, AT WHAT I I 49TH' MICHAEL E, ANDERSON CE-4381 PERCOLATION RATE (mmutes*qnc117 PERC HOLE DIAMETER TEST RUN BETWEEN ~ FT THIS II.~J~.00'60Z /&.00.S0o00 N ~a).0Z'0L~ ~,,OV.90*00 N (iff), t9'Ol.~: ~],,6['.00°00 .1.9'O1.;~ zd -4381 .,AREA MAP '-,..sC~_L~ ~,,= 400; ...... ON-SITE WASTEWATER DISPOSAL SYSTEM CONSTRUCTION AND MATERIAL SPECIFICATIONS SUBJECT: LOT 13, BLOCK 2, NEAR POINT KNOLL SUBDIVISION GENERAL: The scope of this project includes the procurement and placement of a new 1,250 gallon septic tank at the location shown on the site plan. Work also includes the construction of 2 new 60' Io.,ng X 5' wide X .5' effective depth absorption trenches at the location shown. The distribution line in the trench will be placed at 3' below the existing ground surface. A 2' sand. liner is required under the absorption reck, Total depth of the trench w~ll be 5.5' below the existing ground surface. A Zabel Flow Splitter Valve is required to assure equal flow to each trench. All components of the septic system must be placed a minimum of 10' from the water service line on the lot. Construction shall be in accordance with the approved site plan, design drawings, Municipal Permit with any spe. c!al previsions or conditions, and all applicable State and Mumc~pal Wastewater Disposal Regulations. The Contractor shall be responsible for obtaining all underground utility locates and for the layout of the septic system and verification of the location of all lot lines. Unless specifically ~greed otherwise, the contractor shall be responsible for final grading areas subsequently depressed from soil settling. Property owner shall be responsible for revegetation of affected areas unless specifically agreed otherwise. Contractors installing wastewater disposal systems must be certified by the Municipal Department of Health and Human Services for system installations. Owners installing their own syste.ms must receive prior approval from D.H.H.S. before beginning system installation. SEPTIC TANK INSTALLATION 1. A new 1,250 gallon septic tank must be be procured from an approved source and installed at the location shown. A septic tank is to be constructed by a certified septic tank manufacturer. Construction shall include two 4' cleanouts for pumping access. 3. The septic tank shall be sufficiently bedded to prevent settling or shifting of the tank. 4. All standpipes on the septic tank shall extend a minimum of 12 inches above final grade. 5. Tanks installed without 4' of cover shall have a minimum of 2" of direct budal insulation. Lot 13, Block 2, Near Point Knoll Subdivision April 3, 2001 Page 2 of 3 6. A foundation cleanout shall be installed one to four feet from the building foundation. Two cleanouts are required between the tank and the drainfield. 7. Final grading over the tank shall be such that a positive slope exists away from the septic tank. DRAINFIELD CONSTRUCTION: 1. The drainfield shall be constructed to the dimensions shown on the design. The bottom of the trench shall be within 2" of level. 2. Distribution piping must be placed level with perforations down atop a level bed of drainfield rock. Rock should then be placed over the pipe to provide a minimum of 2' of cover. 3. A silt barrier or geotextile fabdc must be placed between the drainfield rock and the natural soil backfill. 4. Monitor tubes must be 4" in diameter and installed at the locations shown on the design. The portion below ground must be perforated. 'Contractor shall vedfy the septic tank and drainfield are a minimum 100' away from any pdvate water wells in the area, 150' from a Class 'C' Well or 200' from any community well. Direct bury insulation must be placed over the distribution system if less than 3' of backfill depth is available. Finish grade over the trench must be mounded to prevent settlement or depressions. 7. Grade area surrounding the absorption trenches to drain away. A minimum 2' of accepting soil is required below the drainfield rock for a 5' wide trench. Contractor shall verify this condition prior to placement of the rock. All pockets of unacceptable materials must be removed and replaced. MATERIAL SPECIFICATIONS: 1. Septic tanks must be constructed by a municipally approved septic tank manufacturer. 2. The following pipe materials are approved for use in septic system installations in the Municipality of Anchorage: Cast Iron (perforated and solid), ASTM D3034 or P.V.C. (perforated and solid), ASTM F810 or H.D.P.E. (perforated, but not solid) and ASTM D2662 or A.B.S. (perforated and solid). 3. Insulation shall be at least 2' thick extruded direct budal polystyrene (Dow Chemical Co. Styrofoam HI or equal). 4. Septic tank inlets and outlets shall be fitted with watertight couplings (Caulder, Femco, or equal). Lot 13, Block 2, Near Point Knoll Subdivision April 3, 2001 Page 3 of 3 5. A permeable geotextile fabric (Typar, Mirafi or equal) must be installed between the final drain rock layer and the native soil layer. 6. All drain rock shall be .5" to 2.5" in diameter with less than 3% passing the #200 sieve. INSPECTIONS: Municipal Ordinance requires a minimum of two inspections. These inspections must be conducted under the supervision of a professional engineer registered in the State of Alaska. The first inspection must be conducted after the excavation of trenches, beds or pits and before the installation of any gravel. A septic tank may be set in place, but may not be backfilled. The second inspection must be conducted after the placement of the geotextile fabdc, gravel, distribution piping, standpipes, cleanouts and insulation. No backfill should be in place at the time of inspection. Contractor shall provide a copy of all field survey layout and construction notes for use in preparing the certified as-built of the completed system. EPtrtNS MUNICIPALITY OF ANCHORAGE Development Services Department ` , Phone: 907-343-7904 On -Site Water & Wastewater Section - Fax: 907-343-7997 Certificate of On -Site Systems Approval Parcel I.D. 041-021-54 1. GENERAL INFORMATION Expiration Date: _? - 7 - Z bu Complete legal description Near Point Knoll, Block 2, Lot 13 Location (site address) 6355 Kalmia Circle Anchorage, AK Current property owner(s) Mario & Mary Lanza Day phone 907-250-8232 Mailing address Real estate agent 11411 Discovery View Drive, Anchorage, AK 99515 Connor Becia 2. TYPE OF DWELLING: ❑■ Single Family (w/wo ADU) ❑ Duplex ❑ Multiple Dwellings (Single Family and/or Duplex) Day phone (907) 903-0039 3. NUMBER OF BEDROOMS: 4 4. TYPE OF WATER SUPPLY: TYPE OF WASTEWATER DISPOSAL: Private Well ❑ Private Septic ❑■ Water Storage ❑ Holding Tank; ❑ Community Well FE Community ❑ Public Water System ❑ Public Sewer ❑ Waiver request for: Distance: Received by: Date: COSA to be released to the engineer, unless otherwise requested by the engineer. COSA Fee $ a� , w Waiver Fee $ Date of Payment Date of Payment Receipt Number Receipt Number COSA # 65 c ao 1009 Waiver # 5. STATEMENT OF INSPECTION BY ENGINEER As certified by my seal affixed hereto and as of the validation date shown below, I verify that my investigation, based on procedures outlined in the Certificate of On -Site Systems Approval Guidelines for this application, shows that the on-site water supply and/or wastewater disposal system is (are) safe, functional and adequate for the number of bedrooms and type of structure indicated herein. I further verify that based on the information obtained from the Municipality of Anchorage files and from my investigation and inspection, the on-site water supply and/or wastewater disposal system is (are) in compliance with all applicable Municipal and State codes, ordinances, and regulations in effect at the time of installation. I acknowledge that On -Site staff may visit the site to verify the information submitted. Name of Firm Forge Civil Engineering Phone 907-522-7773 Address P.O. Box 240773 Anchorage, AK 99524 Engineer's Printed Name Michael E. Anderson, P.E. Date 2/11/2020 6. DSD SIGNATURE System #1 Approved for q bedrooms System #2 Approved for bedrooms Disapproved Conditional approval for bedrooms, with the following stipulations: Original Certificate Date:_.—Gq-2_1C9Zj6 The Municipality of Anchorage Development Services Division (DSD) issues Certificates of On -Site Systems Approval (COSA) based only upon the representations given in paragraph 5 by an independent professional civil engineer registered in the State of Alaska. The Municipality of Anchorage is not responsible for errors or omissions in the professional engineer's work. 7. ATTACHMENTS: COSA Checklist X Nitrate Advisory Septic System Advisory Arsenic Advisory Well Flow Advisory Other COSA Checklist blue sheet Legal Description: Near Point Knoll, Block 2, Lot 13 If more than 1 septic system on lot: COSA Checklist # of A. WELL DATA ❑ Well log is filed with Onsite (or attached) Date drilled Total depth ft Cased to ft ❑ Sanitary seal is functioning correctly ❑ Wires are properly protected Casing height (above ground) in. Date of flow test for COSA Static water level at beginning of test ft. Comments Community Well - Class A - PWSID No. 218642 B. TANK DATA Age of tank(s) <1 years Tank type/material Septic/Plastic Measured operating fluid level in septic tank New ❑ Standpipes/foundation cleanout per record drawing Date of pumping New Septic Tank - 2/7/2020 D. ABSORPTION FIELD DATA Deep Trench Which system tested (date installed) 06/08/01 ❑ ALL standpipes present per record drawing Total measured depth from grade 11.8 ft (max) Measured depth to pipe invert from grade 5.9 ft (min) ❑ N/A — pressurized field ❑ Monitor tubes go to bottom of effective. If not, state depth into effective 5.9 Parcel ID: 041-021-54 Structure served by this system Well production at time of test gpm Water storage tank volume gallons Well disinfected for coliform test? ❑ Yes ❑ No ❑ Coliform bacteria is Negative Nitrate mg/L ❑ Nitrate less than MRL (ND) Arsenic ug/L ❑ Arsenic less than MRL (ND) Collected by _ Date of Sample C. LIFT STATION ❑ Required maintenance completed Age of lift station years Lift station material Comments: Adequacy test date 1/27/20 Results FV]Pass For 4 bedrooms Fluid depth prior to test 0 in Water added 610 gal New depth 0 in Elapsed time 120 min Al Code -required soil cover over field Final fluid depth 0 in ❑ System presoaked Absorption rate >600 gpd (Required if vacant for greater than 30 days prior to Any rejuvenation treatment (past 12 months) No date of test) Gallons introduced 2,000 gallons If yes, enter date Comments/Deficiencies: COSA Checklist yellow sheet E. SEPARATION DISTANCES From Private Well on Lot to: (Please enter distances if less than required or if community well) Septic Tank/Lift Station on Lot > 100' 121 Yes Community Sewer Manhole/Cleanout > 100' Q Yes if No ft Q Yes if No ft Neighboring Tank > 100' Yes if No ft Private Sewer/Septic Line > 25' F,71 Yes if No ft Absorption Field on Lot > 100' Yes if No ft Holding Tank > 100' Q Yes if No ft Neighboring Absorption Fields > 100' Yes if No ft Water Main > 10' Animal Containment > 50' 0 Yes if No ft Q Yes if No ft Q Yes if No ft Water Service Line > 10' M Yes if No Manure/Animal Excreta Storage > 100' If septic tank is under driveway comment below Community Sewer Main > 75' 0 Yes if No ft 0 Yes if No ft From Septic/Holding Tank on Lot to: (Please enter distances if less than required) Building Foundations > 10' 121 Yes if No ft Surface Water > 100' Q Yes if No ft Property Line > 5' 0 Yes if No ft Wells on Adjacent Lots: 0 Absorption Field > 5'✓� if No Yes if No ft Private Wells > 100' Yes if No ft Water Main > 10' 0 Yes if No ft Community Wells > 200' Q Yes if No ft Water Service Line > 10' M Yes if No ft If septic tank is under driveway comment below From Absorption Field on Lot to: (Please enter distances if less than required) Building Foundation > 10' U Yes if No ft If absorption field is under driveway comment below Property Line > 10' 0 Yes if No ft Wells on Adjacent Lots: Water Main > 10' 0 Yes if No ft Private Wells > 100' El Yes if No Water Service Line > 10' M Yes if No ft Community Wells > 200' Q Yes if No Surface Water > 100' Q Yes if No ft F. ENGINEER'S COMMENTS Lot is served by a Class A Community Well. Septic tank replaced 2/7/2020. G. ENGINEER'S CERTIFICATION Q 1 certify that I have determined through field inspections and review �'� P;.••'' "'� of Municipal records that the above systems are in conformance with 4V MOA COSA guidelines in effect on this date. ;• 49th wnuu......na..vo.nn..vannu........ MICHAEL E. ANDERSON No. CE -4381 A�D•.,.,�2/11/20, ,.�i�`& COSA Checklist yellow sheet ROFESSMtima 1P ft ft D o z a D no m 3: 0 O p n m z Na p " C/) C co - — Ln N r r a N p n z cn D p p m r m S c 4n � m m z Nmz Om Z;U= D -4 X 0 -0 < -1 00, Z D m m m m m N ;a -p , n CDO;J DZM �0mm S Z;U > K S D ;U m O N Z ZZmn- r -( ;a S MOO I S-< z D Z m z N ;a K: n On m W N n M M M-0 z ,2 - 0 Oocm ONn -*i z m O ;L7 m z -� -< Z n m m x N mm m O z mN mC/) >< 0-1 ;D ;0 00- n-, -i CANS N p D �IDO;iImr,DD M zAnz -i m i N z -< n 0 0 4n -<m0 M OO O m" 5 m x<- 0 m N p z O n m S o m m �D D m c 0 W D S p m z n c p S z D Ofm�i o rp <_ S O N= C r z D mZ > z Z O p> m 0- m D M O z O m- n Z m eta ° ° N v It F— -0 -O0 z (b N � � Nm O W F— F— � DO�� n co m N Co O z Municipality of Anchorage Development Services Department Building Safety Division On-Site Water and Wastewater Program 4700 South Bragaw St. P.O. Box 196650 Anchorage, AK 99519-6650 www.ci.anchorage.ak.us (9O7) 343-7904 CERTIFICATE Of HEALTH AUTHORITY APPROVAL FOR A SINGLE FAMILY DWELLING Parcel I.D. 041-021-54 1. GENERAL INFORMATION Complete legal description Expiration Date: '7- / Z~ - d3 ~ Lot 13, Block 2, Near Point Knoll Subdivision Location (site address or directions) Kalmia Circle Current Prepedy owner(s) Spinell Hemes, Inc, Day phone 344-5678 Mailing address 9210 Van.quard Ddve Anchoraqe, AK 99507 Lending agency Day phone Mailing address Real Estate Agent Day phone Mailing Address Unless otherwise requested, HAA will be held by DSD for pickup. 2. NUMBER OF BEDROOMS: Four~) 3. TYPE OF WATER SUPPLY: Individual Well Individual Water Storage Community Class A Well Public Water System TYPE OF WASTEWATER DISPOSAL: Individual On-site [] Individual Holding tank [--I [] Community On-site [] [] Public Sewer [] The Municipality of Anchorage Development Services Department (DSD) Issues Certificates of Health Authority Approval (HAA) based only upon the representations given in paragraph 5 by an independent professional civil engineer registered in the Slate of Alaska. Certificates of Health Authority Approval are required for the transfer of title (except between spouses) for properties served by a single family on-site wastewater disposal and/or water supply system. DSD also issues HAAs upon request to homeowners. Certificates of Health Authority Approval are valid for 90 c~ays from the date of issue for properties served by a private or Class C we!l and may be reissued with new water sample results less than 30 days old. (Certificates may be reissued for a period of up lo one year with valid water samples.) Certificates are valid for one year for properties served by Class A or B wells or a public water system. The Municipality of Anchorage is not responsible for errors or omissions in the professional engineer's work. 4. STATEMENT OF INSPECTION BY ENGINEER As certified by my seal affixed hereto and as of the validation date shown below, I verify that my investigation, based on procedures outJined in the Health Authority Approval Guidelines for this application, shows that the on-site water supply and/or wastewater disposal system is(are) safe, functional and adequate for the number of bedrooms and type of structure indicated herein. I further vedfy that based on the information obtained from the Municipality of Anchorage files and from my investigation and inspection, the on-site water supply and/or wastewater disposal system is(are) in compliance with all applicable Municipal and State codes, ordinances. and regulations in effect at the time of installatioo. Name of Firm Anderson Engineerinq Address P.O. Box 240773 Anchoraqe~ AK 99524 Engineer's Printed Name Michael E, Anderson~ P.F_ 5. DSD SIGNATURE Approved for J.~ bedrooms. Disapproved, Phone 522-7773 Conditional approval for bedrooms, with the following stipulations: Additional Comments Attachments: HAA Checklist Septic System Advisory Well Flow Advisory Maintenance Agreements Supplemental Engineer's Report Other Odginal Certificate Date: 7--/~" C'"' Municipality of Anchorage Development Services Department Building Safety Division On-Site Water & Wastewater Program 4700 South Bragaw St. P.O. Box 196650 Anchorage, AK 99519-6650 www.ci.anchorage.ak.us (907) 3437904 HEALTH AUTHORITY APPROVAL CHECKLIST Legal Description: Lot 13, Block 2, Near Point Knoll ,Subdivision A. WELL DATA Well type Public Water Date completed __ Total depth __lt. If A, B, or C provide PWSID # 218642 San~a~y se~ (Y/N) Cased to fl. Co Parcel ID: 04t.~21.54 Well Log (Y/N). FROM WELL LOG Date of test Static water level We, pmducaon WATER SAMPLE RESULTS: Date of sample~ SEPTIC~IOL~INO TANK DATA Tank Type/Material Septi~JSteet g.p.m. Nitrate Collected by: w~ras prope~ protected (Y/N) Casing height (above ground) AT INSPECTION g.p.m. in. Date installed 6Rl2001 Tank s~ ~S~ gel. Foundation claanout (Y/N) Y Date of pumping ABSORPTION FIELD DATA Date installed 6/~/2001 Length 41 Total depth 11 ff. Date of ade(lUany test Number of C~mpartmonts _2 Depression over tank (Y/N) Pumper Cleanoute (Y/N) Y High water alarm (Y/N) N Soil rating (g.p,d./f~ or ~/bdrm) t.2 GPD/SF System type Deep Trench fl. W~dth 3 fl. Gravel below pipe 7 Eft. absorption area 574 fi2 Monitoring tube Y_ Deprassm over field N Results (Pass/Fail) Fluid dep~ in absorption field bofore test __ in. Water added gal. Elapsed Time: min. Final fluid depth in. Absorption rate >: Any rejuvenatk)n treatment (past 12 mo.) (Y/N & type) N If yes, give data For bedrooms New depth in. g.p.d. --mg./1. Other becteda colonies/100 mi. D. UFT STATION Date installed "Pump on' level at in. Datum E. SEPARATION DISTANCES Size in gallons 'Pump off' level at __ Cycles tested SEPARATION DISTANCES FROM VVELL ON LOT TO: Septic tank/lift station on lot Absorption field on lot Public sewer main Sewer/septic service line · in. Manhole/Access (Y/N) High water alarm level at Meets alarm & circuit requirements? in. On adjacent lots On adjacent Jots Public sewer manhole/cieanout Holding tank SEPARATION DISTANCES FROM SEPTIC/HOLDING TANK ON LOT TO: Building foundation >5' Property line >5' Absorption field >5' Water main N/A Water service line ' >10' . Sudace water >100' Wells on adjacent lots >200' SEPARATION DISTANCE FROM ABSORPTION FIELD ON LOT TO: Property line >10' Water Sewice line >t0' Curtain drain None Noted F. COMMENTS Building foundation >10. Surface water >100' Wells on adjacent lots >200. Water main >10' · Drlveway, partdn~vehicieltmage >10' G. ENGINEER'S CERTIFICATION I certify that I have determined through field inspections and mvlew of Municipal reconfs that the above sy~em$ are in conformance with MOA HAA guidelines in effect on this date. Engineer's Printed Name Michael F.. Anderson, P.E. Date 7115/2002 Date of Payment ~ '~* J'~ ~' ('~ (Rev. 12~oo) Waiver Fee $ Date of Payment Receipt Number