HomeMy WebLinkAboutDALZELL-SCHNEITER BLK 2 LT 7 Lot 8 1 Lot 6 Rampart Subd. No. 1 Lot 7 8455A Summit Estates I N89057'00"E 170.00 I Lot 8 11 EASE TS OF RECORD, OTHER THAN TH98E SHOWN ON THE RECORDED PLAT ARE NOT SHOWN HEREON. — -q 10' Utili Easement ------------- N Q0 W a? M greenhouse fence a a JOCVy CD ec agr°b ? e 5eQ � CID O CO M w aB w3b `ct, i2.5 OH 5 3$• I=rM".. Lot 7 OH `Copp QPM Holt, FB 17-1, pg 54 BE The location of the structure(s)as shown on this record drawing SCALE: 1 "= 50' Lot 6 AP�� ao400 h9th *,j 00 41A%Fred Walatka. oo �� "rF • 3255 - S AW y . N NFrssloN �RTIFIED � AS -BUILT NO CORN€€RS SET THIS DATE I hereby certify that I have performed a Mortgagee's inspection of the following described property: LOT 7. BLOCK 2. DALZELL-SCHNEITER SUBDIVISION Anchorage Recording Precinct, Alaska, and that the improvements situated thereon are within the property lines and do not overlap or encroach on the property lying adjacent thereto, that no improvements on the property lying adjacent thereto encroach on the premises in question and that there are no roadways, transmission lines or other visible easements on said property except as indicated hereon. Dated at Anchorage, Alaska this 18th day of APRIL 2017. FRED WALATKA & ASSOCIATES Engineers and Surveyors (907-24&1866) �� moo MUNICIPALITY OF ANCHORAGE . - nll'11I On-Site Water & Wastewater Program -after'.. PO Box 196650 4700 Elmore Road �. 44 Anchorage,Alaska 99519-6650 Phone:(907)343-7904 Fax•(907)343-7997 http://www.muni.org/onsite .. _ I)tlartmcnt 4hcHOpGE On-Site Wastewater Disposal System Permit `f/251/7 Permit Number: OSP171062 Effective Date: 4/24/2017 Work Type: SepticTank Upgrade Expiration Date: 4/24/2018 Tax Code Number: 01529119000 Site Legal Address: DALZELL-SCHNEITER BLK 2 LT 7 G:2537 Site Mailing Address: 5603 DALZELL CIR, Anchorage Owner: RUDD CURT A Lot Size in Sq Ft: 53174 Design Engineer: Total Bedrooms: 3 This permit is for the construction of: El Disposal Field 0 Septic Tank ❑Holding Tank El Privy ❑ Private Well ❑ Water Storage All construction shall be in accordance with: 1. The attached approved design. 2. All requirements specified in Anchorage Municipal code Chapters 15.55 and 15.65 and the State of Alaska Wastewater Disposal Regulations (18AAC72) and Drinking Water Regulations (18AAC80) 3. The wastewater code requires inspections during the installation. The engineer shall notify the Development Services Department per AMC 15.65. Provide notification by calling (907) 343-7904 (24/7). 4. From October 15 to April 15, a subsurface soil absorption system under construction during freezing weather shall be either: a. Opened and Closed on the same day, or b. Covered, sealed, and heated to prevent freezing /1- 12411 Received By: _ /IF Date: 7- Issued By: L� I� _ __ Date: 1/-2--Ly1-7 MUNICIPALITY OF ANCHORAGE Community Development Department tib � rho P• •Fl+�:`90 - '04 Development Services Division , ' a USH3-''•- On-Site Water & Wastewater Program a APR z 1 L11/ )1 ON-SITE SEWER/WELL PERMIT APPLICATI• �� I . ti " Parcel I.D. 015-291-19-000 i` as Q Lg c Property owner(s) Curt and Renee Rudd Day phone 907-748-7079 Mailing address 5603 Dalzell Circle, Anchorage AK 99507 Site address Same Legal description (Sub'd., Block & Lot) Lot 7, Block 2, Dalzell-Schneiter Legal description (Township, Range & Section) Lot Size 53,174 Sq. Ft. Number of Bedrooms 3 APPLICATION IS FOR: APPLICATION IS AN: TYPE OF DWELLING: (®all that apply) Absorption Field ❑ Initial ❑ Single Family (SF) x❑ (w/wo ADU) Septic Tank ❑x Upgrade Y Duplex (D) ❑ Holding Tank ❑ Renewal ® Multiple Dwellings ❑ Privy ❑ (SF and/or D) Private Well ❑ Water Storage ❑ THIS APPLICATION INCLUDES A VARIANCE /WAIVER REQUEST FOR: Distance: I certify that the above information is correct. I further certify that this is in accordance with applicable Municipal Codes. CrliA4--'-- (Signature of property owner or authorized agent) Permit/Rush Fees: 4(3 tic/ Waiver Fees: Date of Payment: g1211/? Date of Payment: Receipt Number: 047KG—ca Receipt Number: Permit No. 05 P/ IO( L Waiver No. Permit App_ -.• ::...c Arete LLC 101 W. Harvard Ave Anchorage,AK 99501 (907)441-5772 April 21, 2017 Municipality of Anchorage On-Site Water and Wastewater 4700 Elmore Road Anchorage, Alaska 99507 Re: Septic Tank Replacement and garage addition at Lot7, Block 2, Dalzell-Schneiter Subdivision To Whom It May Concern, At the referenced property,the owners will be constructing an addition consisting of a garage and expansion of their living space. Considering the age of the existing steel septic tank (30+years) the owners would like to replace their existing septic tank while work is being done on foundations for the new addition. Scope of work effecting the septic system includes replacement of the existing 1,250 gallon steel tank with a new 1,250 gallon steel tank. Water tight couplings will be used and manhole covers will include gaskets. The discharge line from the existing house will be reconnected to the new tank.The discharge line from the addition will tie into the existing discharge line from the house. The new tank will be reconnected to the existing leech field. The replacement tank is greater than 5'from property lines, greater than 10' from water lines, and greater than 100'from surface water. Replacement of this tank will not negatively affect well or septic systems on adjacent properties. The addition does not increase the number of bedrooms from the originally designed system and therefore no work will be done on the existing leech field. I,Seth Andersen, will be acting as the owners engineer and construction manager for this project. Please feel free to contact me by phone at 907-441-5772 or by email at arete.seth@Rmail.com Regards, eth Andersen, P.E. Arete LLC 907 441 5772 I 1 I LOT 6 RAMPART LOT 6 RAMPART LOT 7 RAMPART ADDITION#1 ADDITION #1 ADDITION#1 100' WELL RADIUS TYPICAL EXISTING LEACH FIELD EXISTING STEEL TANK LOT 6 BLOCK 2 TO BE REPLACED WITH c'-• DALZELL-SCHNEITER 1,250 GAL STEEL TANK 5++:'" opts►H RtQla« e,c.1+ LOT 8 BLOCK 2 DALZELL-SCHNEITER 3-BEDROOM HOUSE WELL WELL LOT 7 BLOCK 2 DALZELL-SCHNEITER 25 50 100 SCALE: 1" = 50' STRUCTURAL DESIGN I PROJECT MANAGEMENT I CONSULTING ARETE, LLC 101 w. harvard avenue I anchorage, alaska 99501 I 907.441.5772 I arete.seth@gmail_com TITLE: LOT 7, BLOCK 2, DALZELL-SCHNEITER SEPTIC TANK REPLACEMENT 001 DATE: 4/21/17 1 DRAWN BY:SFA CHECKED BY:SFA I CLIENT: RUDD f '~IUNICIPALITY OF ANCHORAGE  DEPARTMENT OF HEALTH & ENVIRONMENTAL PROTECTION t ENVIRONMENTAL ENGINEERING DIVISION 825 L Street- Anchorage, Alaska 99501 Telephone 264-4720 ON-SITE SEWAGE DISPOSAL SYSTEM AND/OR WELL INSPECTION REPORT IPHONE NO. OF BEDROOMS d 3 ~ Well Dwelling PERMIT NO. DISTANCE TO: ~ Well Foundalion Nearest 1o, ,,ne~ 0, ~ D~sTa.ct To: 10o/ ~ ~ ~ Length o~a~ ~n, Total ,engthg ~e, Trench .gt~ ~ Distance ~t.en lines ~ ~ ~ Top of Iii. 1o ,ini,h Grade M.leria, ~.ealh ,il. ~ DISTANCE TO: ~ Class Depth Driller Distance to lot hne-- ~ DISTANCE TO: OTHER PIPE MATERIA~ 72-013 (Rev. 3/78) PERMIT H~_lr~ I mS I P,~.-- I TY OF ~r4~Hm~. _~E DEPRRTi'.IEiqT OF"~rERLTH'RND EN'./IROhlMENTRL PROTECTION ~ ~ 825 'L' STREET, AfI~HORRGE, AK. 99501 _ ~;~ t4ELL RND Ot~--5 · TE 5ElqER PERr~ ~ 7-;7-?~ RPPLICR[~T LOCRTION LEGRL CLIRT RLID~ DRLZELL CIRCLE L7 B2 DRLZELL 2940:YRLE DR LOT SIZE ....... 274.3752 ~53174-SQURRE FEET TYPE OF SOIL RBSORBTION Str'STErl IS: MRXIMUFI HUMBER OF BEDROOMS TRENCH 'SOIL RRTING (SQ FT/BR)= ~'~-50~ THE REQUIRED SIZE OF THE SOIL ABSORPTION SYSTEM IS:,.-~:" '" DEPTH= -12 LEI'-.I G TH = --'8--'- GRR%-'EL DEP~H~ THE LENGTH DIMENSION IS THE LENGTH (IN FEET> OF THE TRENCH OR DRRINFIELD. THE DEPTH OF R TRENCH OR PIT I~ THE DISTRNCE E:ETHEEH THE SURFRCE OF THE GROUND RND THE BOTTOM OF THE EXCRVRTION (IH FEET>. THERE IS NO SET HIDTH FOR TREHCHES. THE GRRVEL DEPTH I5 THE MIt~IMUM DEPTH OF GRRVEL BETHEEN THE OUTFRLL PIPE RND THE BOTTOM OF THE EXCRVRTION (IN FEET). ~ {,; .. RE~JIRED SEF'TIC ~ TR[~('- SIZE= 1888 GRLLO[4S PERMIT RPPLICRNT HRS THE RE5PONSIBILITV TO INFOR~.THIS~iDEPRRTMENT DURING THE INSTRLLRTION INSPECTIO/~S OF RNY HELLS RDJRCENT T~..THIS/~PROPERTY.., , .,RND. .THE NUD1BER OF RESIDEHCES THRT THE NELL WILL SERVE. i ~ ~ y..-- TWO ( 2 ) I/~SPECT I OtqS 8~E RE~J I RED BRCKFILLIHG OF,RNV SYSTEM HITHOUT FINRL INSPECTION RND RPPROVRL BY THIS DEPRRTMENT HILL' BE SUBJECT TO PROSECUTION, !~::, ' ........ ~:' '-~ MI/~IMUrt DISTRNCE BETHEEN R HELL RND RNY ON-SIT~ SEH~GE,DISPOSRL 188 FEET FOR R'PRIVRTE HELL~ OR !';q~ ~ 158 TO 288 FEET FROM R PUBLIC HELL DEF'ENDING_UFiON TH~ ~Y~E OF PUBLIC NELL. HELL LOGS RRE REQUIRED RND MUST BE RETURNED ~O.THE ~DEPRRTMENT NITHIN ~8 DRYS OF THE HELL COMPLETION. , /; ~ ~ ~ OTHER REQUIREME/.~TS MRY RPF'LY. SF'ECIFICRTIONS RHD CO/~STRUCTION DIRGRRHS RRE RVRILRBLE TO INSURE PROPER.~IH~TRLLRTION,.; ' , PERt~ I T EXF' I RES pECE~.IBEF: ~l. I CERTIFY THRT ~ ........ , ., l: I R~'I FRMILIRR HITH THE,REQUIREMENTS FOR ON;SITE 5EHERS RND HELLS RS SET FORTH BY THE MUNICIPRLITY OF. RNCHORRGE.~ 2: I HILL INSTRLL THE 5VSTEM"IN RCCORDRNCE HITH THE CODES, ~: I UNDERSTRND THRT THE ON-SITE SEHER S'i'STEM MRY REQUIRE ENLRRGEMENT IF THE RESIDEHCE IS REMODELED TO INCLUDE MORE THRH ~ BEDROOMS. SIGNED: _ MUNICIPALITY OF ANCHORAGE DEPT. O:' I:'.%TH & DEPARTMENT OF HEALTH & ENVIRONMENTAL PROTE&e'I'~:~',~'NTAL I' ;,~T~CTION APR 3 0 979 ENVIRONMENTAL ENGINEERING DIVISION Telephone 264-4720 RECEIVED DIRECTIONS: Comptete all parts on page 1. Ineomegete te~um~ will not be preeemml. Please aUow ten (10) days for processing. PROPERTY RESID~.~T (If dilfecent from abo~) ~ '~ PHONE PHONE 2. BUYER MAILING ADDRESS DDI :ESS 4. REALTOR/AGENT PHONE MAILING ADDRESS TYPEO, r-I One r-I Four ~/' SINGLE FAMILY [] ,,.Two [] Five [] MULTIPLE FAMILY ~ Three [] Six D Other 7. WATE, su~,-Y · ~ INDIVIDUAL* [] COMMUNITY [] PUBLIC UTILITY 8. SEWAGE DISROSAL SYSTEM ~1N DIVI DUAL/ON-SITE ** [] PUBLIC UTI LITY · ATTACH WELL LOG. A well log is required for all wells drilled since June 1975. For wells drilled pr~iv~ell depth (attach log if available.) ..... If ~nd~wdual/on-site, give installation date . If system is over two (2) years old an adequacy test is required by this Department. NOTE: THE INSPECTION FEE MUST ACCOMPANY EACH REQUEST BEFORE PROCESSING CAN BE INITIATED. 72-010(3/78) , ~. THIS SIDE FOR OFFICIAL USE ONLY . !DATE RECEIVED INSPECTION APPOINTMENTS TIME TIME TIME DATE DATE DATE INSPECTOR INSPECTOR INSPECTOR DIRECTIONS: 1. TYPE OF RESIDENCE NUMBER OF BEDROOMS [-'1 SINGLE FAMILY [] ONE [] THREE [] FIVE [] OTHER [] MULTIPLE FAMILY [] TWO [] FOUR [] SIX 2. WATER SUPPLY PERMIT NUMBER [--I INDIVIDUAL DEPTH OF WELL [] COMMUNITY DATE DRILLED [] PUBLIC UTI LITY Connection Verified LOG RECEIVEDJ- 3. SEWAGE DISPOSAL SYSTEM PERMIT NUMBER [] INDIVIDUAL/ON -SITE DATE INSTALLED []PUBLIC UTILITY ~ _--~ ~ Connection Verified INSTALLER []Septic Tank or []Holding Tank ~ ~ Size: (~.~'~ IfTankishomemade SOILS RATING g~ve dimensions:, /f TYPE OF TANK MANUFACTURER TOTAL A~SORPTION AREA MATERIAL 4. DISTANCESwELL TO: Sep,ic/HoidJng Tank IAbsorptJon Area Absorption Area lo nearest Lot Line X;PROVED FOR R DROOMS (letter must accom, ja~ certificate) CONDITIONAL APPROVAL E~-' DISAPPROVED LEGAL DESCRIPTION 72-010 (Rev. 3/78) MUNICIPALITY OF ANCHORAGE DEPARTMENT OF HEALTH & HUMAN SERVICES Division of Environmental Services On-Site Services Section P,O. Box 196650 Anchorage, Alaska 99519-6650 343-4744 Parcel I.D, if CERTIFICATE OF HEALTH AUTHORITY APPROVAL F.OR A SINGLE FAMILY DWELLING 1. GENERAL INFORMATION Complete legal description Location (site add'ress or directions) 5403 Z~a~z~'~ CZ~ Property owner Mailing address Lending agency Mailing address Agent Address P.O.Box 1114~5 Ancho~ccqe~ ,4J~6h.a. 99511-14~$ Day phone Day phone e Unless otherwise requested, HAA will be held for pickup. NUMBER OF BEDROOMS: TYPE OF WATER SUPPLY: Individual well Community well Public water NOTE: If community well system, provide written confirmation from State ADEC attest- ing to the legality and status of system. 4. TYPE OF WASTEWATER DISPOSAL: Individual on-site Y,X ' · Holding tank Community on-site Public sewer '%' 'NOTE: If community wastewater system, provi, de written confirmation from State ADEC · attesting to the legality and status of system. SE STATEMENT OF INSPECTION BY ENGINEER .. .. As certified by my seal affixed hereto and as of the validat[(~n date shown below, I verify that my investigation of this Health Authority Approval application shows that the on-site water supply and/or wastewater disposal system is safe, functional and adequate for the number of bedrooms and type of structure indicated herein. I further verify that based on the information obtained from the Municipality of Anchorage files and from my investigation and inspection, the on-site water supply and/or wastewater disposal system is in compliance with all Mdhicipal and State codes, ordinances, and regulations i.n effect.on the date ~3f this inspection. Name of Firm Address Engineer's signature Phone Date ~" ~- ~ 'Z.-- DHHS SIGNATURE X~ Approved for ~')-~E'~/~,~ bedrooms. Disapproved. Conditional approval for bedrooms, with the following stipulations: Additional Comments ' The Municipality of Anchorage Department of Health and Human Services (DHHS) issues Health Authority Approval Certificates based only upon the representations given In paragraph 5 above by an independent professional engineer registered in the State of Alaska. The DHHS does this as a courtesy to purchasers of homes and their lending institutions in order to satisfy certain federal and state require~nents. Employees of DHHS do not conduct inspections or.analyze data before a certificate is issued. The Municipality of Anchorage Is not responsible for errors or omissions in the professional engineer's work. A. WELL DATA ': Well type ~ If A, B, or C, attach ADEC letter, ADEC water system number Municipality of Anchorage ~, Department of Health & Human Services HEALTH AUTHORITY APPROVAL CHECKLIST Log present (~N) Y~ Datecompleted Driller ~E~,,v~ ~ Totaldepth ~2--~' Cased to ~O'4- Casing height ~n Sanita~ se~J ~N) ~ Wires properly protected~N) ~ g.p.m~ ~ FROM WELL LOG Date of test Static water level Well flow I~, Pump level SEPARATION DISTANCES FROM WELL TO: Septic/holding tank on lot JOe ~ Absorption field on lot /tO0 ~' Public sewer main ~'~q,~- Sewer service line (-~P-~ ~ 4- g.p.m. AT INSPECTION ,' On adjacent lots ; On adjacent lots · Public sewer manhole/cleanout Petroleum tank ~'~ o,~ ~ lOOt,,. /0o '+ WATER SAMPLE RESULTS: Coliform O Nitrate Date of sample: I ~ ~ ~ ct'Z_ ~'~ mO-//'[- Other bacteria Collected by: B. SEPTIC/HOLDING TANK DATA Date installed ~ J ,3,.(~ /'"':k~ Cleanout&(~(N) ~/E..c~ High water alarm (Y/(~ Date of Pumping Tank size I,'3-~O GA-(- Compartments Foundation cleanout (~N) yjE..~, .... Depression (Y/~ Pumper ~ i- ~o~e. To property line Surface water/drainage SEPARATION DISTANCES FROM SEPTIC/HOLDING'TANK TO: Well(s) on lot Iol~ * On adjacentlots /00 t.f._ Absorpt!onfield..' ~ct'" 72-026 (Rev. 7/91) Front Foundation water main/servi¢o lino CONTINUED ON BACK PAGE C. LIFT STATION -- , ..... : " Manufacturer M~'nh le/Access (Y/N) Vent (Y/N) ' ' "Pump off" level at High water alarm level Cycles tested Meets MOA electrical codes (Y/N) ~ , ,~.......~ ~ . ~ . .: SEPARATION DISTANCE FROM LIFT sTATIoN,'~TO,.'," '~~'~ ~. adjacen~ onlot --- ' - On _ Well D. ABSORPTION FIELD DATA, Date installed ' ~ ~ Soil rating J~ 5F/~ System type · Total absorption area C/'~ 5/:= "Depressior;0ver field (Y/~ Gravel thickness Clean0uts present ~N) Results ~s/fail) '~,,~ Peroxide trea, tment (past 12 months) (Y/(~ SEPARATION DISTANCE FROM ABSORPTION FIELD TO: Date of adequacy test for ..~ if yes, give date Total depth ~ ~' / bedrooms Weli On lOtl To building foundation On adjacent lots o,~.0 Surface water /O0'"'F' Curtain drain ~o~z,. E. ENGINEER'S CERTIFIcATIoN On adjacer~t lots - [0(~ ~' Propertyline To existing or abandoned .system on lot Cutbank AJ/,f4. Water main/service line Driveway, parking/vehicle storage area I certify that I ha ve checked, verified, or conformed to all MOA and HAA guidelines in effeC't o~a, date Of this inspection ' S & S ENGINEERING '. Signature ' I 17034 Eaqle Rlve¢ L~ Read Ne, ~,~ E.g n.er's Name .... HAA Fee $ Date of Payment ~'~ ~ '2. 72~ (Rw. ~1) ~k MOA 21 Waiver Fee: $ Date of Payment Receipt Number