HomeMy WebLinkAboutDALZELL-SCHNEITER BLK 2 LT 9bolzell hn itcr Block 2 Lot 9 #015-291-21 kRuv VJ/VL/ 101 Municipality of Anchorage On -Site Water and Wastewater Section • (907) 343-7904 Page 1 of 1 ON-SITE WASTEWATER INSPECTION REPORT Permit Number: OSP201503 PID Number: 015-291-21 Dwelling: 0 Single Family (SF) ❑ with ADU ❑ Duplex (D) ❑ Two Single Family Project: ❑ New 0 Upgrade Name Grant and Sharon Klotz ABSORPTION FIELD ❑® Deep Trench ❑ Wide Trench ❑ Bed ❑ Mound Site Address 10121 Schneiter Cir Anchorage AK 99507 ❑ Other Phone Number of Bedrooms Soil Rating Total depth from original grade 3 1.2 GPD/SF 10 Ft. LEGAL DESCRIPTION Depth to pipe invert from original grade 6 Ft.4 Gravel depth beneath pipe Subdivision Block Lot Balzell-Schneiter 2 9 Ft. Fill added above original grade 0 Ft. Gravel length 40 Ft. Township Range Section Gravel width 5 Ft. Beds: Number of Lines na Distance between lines na Ft. SEPARATION DISTANCES To Septic Absorption Lift Station Holding Sewer Total absorption area Number of trenches Dist. between trenches From Tank Field Tank Line 400 Ftz 1 na Ft. Well 100'+ 1001+ NA NA 25'+ TANK N Septic ❑ S.T.E.P. ❑ Holding ❑ Other Manufacturer GREER Capacity 1000 Gal. Surface Water i 1001+ I 100'+ NA NA Material Number of compartments I i Lot Line 10'+ 10'+NA j NA NA HDPE 2 Foundation 101+ 10'+NA NA LIFT STATION Manufacturer Capacity I I Remarks Gal. Alarm location Electrical installed by Installer PIPE MATERIAL House to tank 3034 Tank to 3034 drainfield A+ Homes Services Drainfield 3034 cOIMT3034 Inspector Pannone Engineering BENCH MARK (Assumed elevation) 100.0 ft Inspection1�t 6/7/21 6/14/21 Location and description es: 2nd 3`d 6/25/21 4°i house foundation ON-SITE WATER AND WASTEWATER SECTION APPROVAL Engineer's Stamp Conditional Approval: Date -SN OF AC gs� - 49 THS --: .. .. .........:.. Septic System Approved &16V A,, R, -b« Carr.11 Date /Z Oa_ Note: this approval does not include well permit requirements. kRuv VJ/VL/ 101 -t K: -9 n m (-) 'R --I< In m 0 0--m co z W o 7[1 c n m m �o mx mmi< aoo OZZ0 U) Do�Mo66 1 W Z O z m O ;u A 11 D r A D F- m m to \ S N N E C� 0< z-crcn RDx -;uz• • Dr O TW n FTI (n .. z� n \ N>O mm�Ez!�m 0 2 n Z W CD (9 0) 6l (Jt U7 -P N _0 rn (D N O -A N U7 U1 C0 po n O N N L4 (D 00 Ut 00 00 m �I Ut Ut (J) m O CJIUt 41 to -P I �u A W -A41 c/)C a I CO Cl) 4, Icil -P U7 U7 6) v -. � N N \ rn I� \ DO riIn DON m K co D Ln -0 —1 z -C;7p m D0 Zwm 'D m [� Z-ir mm T�DX Op z-crcn RDx -;uz• • Dr O TW n FTI (n .. z� n \ N>O mm�Ez!�m N>Ut fJ> D ND -+Fri 0zrnmoC I m Z D x C7 D x 2 G7 .. O CCC) Co F = ooh 0 0 C n X06 � i _0 rn CD O m 0C4 m `4rm*I((n- - •o" N DD n io Deo � CA cn i0 ^ C) -0 4 01 D O q o.. m m 1 O O Z = m a (n (� z 10 O 0 41 to I �u w �m� O c/)C a I D fTl z 0 --1 O Z \ OD 0 rn n m c)0 c0`T'- o C) D Co Z FTI 00 0 �m ODD � 0 LnJ t N of a) 0 NOTES: RECORD DRAWING I _ co t v i n / J \ I n \ r I m \ I o O \ 3 Co o00 I � i _0 rn \ I n m n ===O � 01 ry m m 1 Z \�/ \ (n (� z 10 I �u w �m� \ \ a I O Z \ OD ZI m Lo n m 1 / h >/ j / n 0 \ rn I� \ n IO r C1 O 0 m c)0 c0`T'- o C) D Co Z FTI 00 0 �m ODD � 0 LnJ t N of a) 0 NOTES: RECORD DRAWING PANNONE ENG SVC LLC (C.I. 1088) P.O. BOX 1807 PALMER, AK 99645 - �E of PHONE (907) 745-8200 FAX (907) 745-8201 = �? DALZELL—SCHNEITER 82 L9 DRAWN MMM GRANT & SHARON KLOTZ 10121 SCHNEITER CIR SITE PLAN ANCHORAGE, AK 99507 49t �.. ...Steven one R. nn CE -8749 :' r I _ co t v i n / r I m o Co r— � i _0 rn I n m n ===O � ry m m 1 (n (� z 10 rnz> / ( n m --- r m m m r�o / D Z O 0 / In n In Co MO t J 'T, — r✓ 1 OZ5 \ W J M -i m D D -W _J �r I I w I x 0 � z m a cl)� D r PANNONE ENG SVC LLC (C.I. 1088) P.O. BOX 1807 PALMER, AK 99645 - �E of PHONE (907) 745-8200 FAX (907) 745-8201 = �? DALZELL—SCHNEITER 82 L9 DRAWN MMM GRANT & SHARON KLOTZ 10121 SCHNEITER CIR SITE PLAN ANCHORAGE, AK 99507 49t �.. ...Steven one R. nn CE -8749 :' r REVISIONS DATE / 047r4/2022 03/07/2022 SCALE 1" = 50' P.I.D. NO 015-291-21 PERMIT N0. OSP201503 SHEET 1 OF 1 I _ I t v i n / r I m ` 1 I I / I I\ REVISIONS DATE / 047r4/2022 03/07/2022 SCALE 1" = 50' P.I.D. NO 015-291-21 PERMIT N0. OSP201503 SHEET 1 OF 1 Summit Estates N89057'00"E 183.00 8498E 10' Utility Easement LOT 9 Asphalt encroaches 1.4't Ret. wall (typ) 10' Utility Easement ca 0 W 0 m Lot 8 1 W ca / �\Se93s �r Chain Zink fence (typ) ° 7 R,36 4 Sp 00 <�g 3 SCHNEITER h' -8Q O0 �4J \ AS -BUILT SCALE: 1 "= 60' of .49th ••:9 �� �fiizabeth L. Walatka ; ,o po ��u�F� • 8036 - LS 0 t o.-ESSIONpL•LAN NO CORNERS SET THIS DATE I hereby certify that I have performed a Mortgagee's inspection in accordance with ASPLS Standards of the following described property: LOT 9, BLOCK 2, DALZELL-SCHNEITER SUBDIVISION Anchorage Recording Precinct, Alaska, and that the improvements situated thereon are within the property lines and do not overlap or encroach on the property lying adjacent thereto, that no improvements on the property lying adjacent thereto encroach on the premises in question and that there are no roadways, transmission lines or other visible easements on said property except as indicated hereon. Dated at Anchorage, Alaska EASEMENTS OF RECORD, OTHER THAN this 31st day of AUGUST , 2021. THOSE SHOWN ON THE RECORDED FRED WALATKA & ASSOCIATES, L.L.C. PLAT ARE NOT SHOWN HEREON Engineers and Surveyors UNLESS OTHERWISE NOTED. FB 21-3, pg 62-64 BE 907-248-1666 This drawing is a representation of conditions found at the time the mortgage location survey was performed. This document does not constitute a boundary survey and is subject to any inaccuracies that a subsequent boundary survey may disclose. The information contained on this drawing shall not be used to establish any fence. structure or other improvements. This drawing shall only be used for a single property transaction. Use of this drawing by the original client or by others at a later date without the consent of Elizabeth L. Walatka is a violation of Federal Copyright law. Unless gross negligence is discovered, the liability extent of the preparer is limited to the amount of fees collected for services in preparation of this product. MUNICIPALITY OF ANCHORAGE On -Site Water & Wastewater Program PO Box 196650 4700 Elmore Road Anchorage, Alaska 99519-6650 Phone: (907) 343-7904 Fax: (907) 343-7997 http://www.muni.org/onsite On -Site Wastewater Disposal System Permit Permit Number: OSP201503 Work Type: Septic Upgrade Tax Code Number: 01529121000 Site Legal Address: DALZELL-SCHNEITER BLK 2 LT 9 G:2537 Site Mailing Address: 10121 SCHNEITER CIR, Anchorage Owner: KLOTZ GRANT D & SHARON K Design Engineer: PANNONE ENGINEERING SERVICES This permit is for the construction of: Q Disposal Field R1 Septic Tank ❑ Holding Tank ❑ Privy Effective Date: Expiration Date �a_4 �r U l L)CI)Ell'CII7('l7i Lot Size in Sq Ft: Total Bedrooms: 5/17/2021 5/17/2022 ❑ Private Well ❑ Water Storage All construction shall be in accordance with: 1. The attached approved design. 2. All requirements specified in Anchorage Municipal code Chapters 15.55 and 15.65 and the State of Alaska Wastewater Disposal Regulations (18AAC72) and Drinking Water Regulations (18AAC80) 3. The wastewater code requires inspections during the installation. The engineer shall notify the Development Services Department per AMC 15.65. Provide notification by calling (907) 343-7904 (24/7). 4. From October 15 to April 15, a subsurface soil absorption system under construction during freezing weather shall be either: a. Opened and Closed on the same day, or b. Covered, sealed, and heated to prevent freezing 3 Tb) x 3 �s L —� elx k e 4, e o f Received By: Date: _ Issued By: -1' f%C� �^ Date: MUNICIPALITY OF ANCHORAGE Community Development Departments Phone: 907-343-7904 Development Services Division Fax: 907-343-7997 On -Site Water & Wastewater Program ON-SITE SEWER/WELL PERMIT APPLICATION Parcel I.D. 015-291-21 Property owner(s) GRANT & SHARON KLOTZ Day phone Mailing address 10121 SCHNEITER CIR, ANCHORAGE AK 99507 Site address 10121 SCHNEITER CIR, ANCHORAGE AK 99507 Legal description (Sub'd., Block & Lot) DALZELL-SCHNEITER B2 L9 Legal description (Township, Range & Section) Lot Size 50,089 Sq. Ft. Number of Bedrooms 3 APPLICATION IS FOR: APPLICATION IS AN: TYPE OF DWELLING: (® all that apply) Absorption Field Initial ❑ Single Family (SF) ❑X (w/wo ADU) Septic Tank ® Upgrade 0 Duplex (D) ❑ Holding Tank ❑ Renewal El Multiple Dwellings ❑ Privy ❑ (SF and/or D) Private Well ❑ Water Storage ❑ THIS APPLICATION INCLUDES A VARIANCE / WAIVER REQUEST FOR: Distance: I certify that the above information is correct. I further certify that this is in accordance with applicable Municipal Codes. (Signature of property owner or authorized agent) Permit/Rush Fees: $446.25 (COVID-19) Waiver Fees: Date of Payment: / ZZlgho Date of Payment: Receipt Number: n�Oq I r Receipt Number: Permit No. OSP201503 Waiver No. Permit App_---.. ;:...:c: Municipality of Anchorage On-site Water and Wastewater REVIEWED FOR CODE COMPLIANCE OSP201503, Rebecca Carroll, 05/17/21 Municipality of Anchorage On-site Water and Wastewater REVIEWED FOR CODE COMPLIANCE OSP201503, Rebecca Carroll, 05/17/21 Municipality of Anchorage On-site Water and Wastewater REVIEWED FOR CODE COMPLIANCE OSP201503, Rebecca Carroll, 05/17/21 Municipality of Anchorage On-site Water and Wastewater REVIEWED FOR CODE COMPLIANCE OSP201503, Rebecca Carroll, 05/17/21 ]D~te of Issue: __ ?~rcel Ideniificadon Number:__ ~p ~ke Depth Below Top of~e~ Cas~g: ~ feet Size /~ hp piiless A. dap~ar Buriml Depth:/~9 feet r" ~ MUNICIPALITY OF ANCHORAGE ( ~ DEPARTMENT OF HEALTH & ENVIRONMENTAL PROTECTION ENVIRONMENTAL ENGINEERING DIVISION 825 L Street o Anchorage. Alaska 99501 Telephone 264-4720 ON-SITE SEWAGE DISPOSAL SYSTEM AND/OR WELL INSPECTION REPORT ! PHONE [] UPGRADE Material ~._ N°' of compartments 0 z ~ Manufacturer _~ Material ,iquid capacity in ~llons a = = DISTANCE TO: Well ~ ~ Foundation ~ Nearestlot hne ~5 PEffiMtT NO. NO. of lin6 L~ngth of each line~ lotal length of lines = I~ T~ of tile to finish grade ~1 0'1 Matedal beneath tile G~ 0t~ inches < ~ Type of crib i d, ,m Crib depth Total eff~ti~ absorption area 0 OTHER PIPE UATERIA~ ~~ O 5 ~ ~ INSTAkLER~T '~ ~ q" REMARKS 72-013 (Rev. 3/78) DAILY DRILLING tOG SYREN BROS. DRILLING, INC. 2701 £sile Street Anchorsge. Alaska 99503 274-6437 KIND OF FORMATION: FRO~.........O. ............... rT. ~oM..._...6.!:. ........... rT. FROM ........ 1.2. ........... rT. FROM ........ 52 ............ FT. FRO~ ........ .65. ........... rT. FROM ........ 7.0 ........... FT, FROM ........ 7.~. ......... rT. ntoM ........ 8.5. ........... rT. FROM ......................... rT. TO......:..l.2 ......... rT~nd~...graxrel.. TO ......... 52 ........ FT$.al~. ........................... TO..'...~5 .......... rT.~,m~t...sLl~c y...s a nd few gravel TO .......... 7.0 .......... rT$.il~. ......................... TO ........ ?.~ ......... P~il.~...and...f e~.. gravel TO ........ -~5 .......... ~T~e.~...graMel ......... TO ......... .8.2 ......... rTgraMel .&...H20.. ,E~I, OF W~U- ................... .8.11 ............................................................. STATIC LEVEL OF WATER DRAW DOWN FT ............................................................................. .' ................... ~Ats. PER .~. ................. .?....g~ll.ons...p~n..minu~.e ................... X~NV O~ CASINO ........... 6.'.'....l.7lb.....grad~...B ................................... TO *~0~ FRo,,, .......................... rT .......... ......._.......,~, .......~. ............ FROM .......................... FT. TO ................. .D....,,~iI~ .................................. ~~*°~'~ _ a .......................... ~. ,o .......................... ~ ~.%:.:..~-.~ ................. FROM ~OM .......................... ~. ~o .......................... ~....-~.~.~%1.%~ ......... .OM .......................... .......................... ............. FROM .......................... ~. TO ........... ~ .............. ~ ........................................ FROM .......................... ~. TO .......................... ~ ......................................... FROM ......................... ~. TO .......................... ~ ......................................... FROM .......................... ~. TO .......................... ~ ......................................... FROM .......................... rT. TO ......................... FT ........................................ FROM .......................... FT. TO .......................... FT ......................................... FROM ......................... FT. FROM ......................... FT. FROM .......................... FT. TO .......................... FT ......................................... FROM .......................... FT. TO .......................... FT ........................................ MISCL, INFORMATION: DRILLER'S NAME .................. ~t ephen...D.~....Syren ................................... APPLICANT LOCATION LEGAL LIS8 HILLER 1200 W. SCHNEITER CIRCLE L~ B2 DALZELL-SCHNEITER SIMONS SP 1014 LOT SIZE 244 7701 49000 SQUARE FEET TYPE OF SOIL ABSORBTION SYSTEM IS: TRENCH HAXIMUM NUMBER OF BEDROOMS SOIL RATING (S~ FT/BR)= 125 THE REQUIRED SIZE OF THE SOIL ABSORPTION SYSTEM IS: DEPTH---- lid LENGTH= :~: ::~ GRFI~,.'EL DEPTH= ~.. THE LENGTH DIMENSION IS THE LENGTH (IN FEET> OF THE TRENCH OR DRAINFIELD. TWE DEPTH OF A TRENCH OR PIT IS THE DISTANCE BETWEEN THE SURFACE OF THE GROUND AND THE BOTTOM OF THE EXCAVATION (IN FEET). THERE IS NO SET WIDTH FOR TRENCHES. THE GRAVEL DEPTH IS THE MINIMUM DEPTH OF GRAVEL BETWEEN THE OUTFALL PIPE AND THE BOTTOM OF THE EXCAVATION (IN FEET). REQU I RED SEPT I 0 TI:INK _c; I ZE= ::LOIDID GF:tLLOI'-I$ PERMIT APPLICANT HAS THE RESPONSIBILITY TO INFORM THIS DEPARTMENT DURING THE INSTALLATION INSPECTIONS OF ANY WELLS ADJACENT TO THIS PROPERTY AN[) THE NUMBER OF RESIDENCES THAT THE WELL WILL SERVE. TI40 ( ~: > I NSPEI~T IONS fIRE REQLI I RED BACKFILLING OF ANY SYSTEM WITHOUT FINAL INSPECTION AND APPROVAL BY THIS DEPARTMENT WILL BE SUBJECT TO PROSECUTION. HIrIIMUM DISTANCE BETWEEN A WELL Arid ANY ON-SITE SEWAGE DISPOSAL SYSTEM IS 100 FEET FOR A PRIVATE WELL; OR 150 TO 200 PEET FROM FI PUBLIC WELL DEPENDING UPON THE TYPE OF PUBLIC WELL WELL LOGS ARE REQUIRED AND MUST BE RETURNED TO THE DEPARTMENT WITHIN ~0 DAYS OD THE WELL COMPLETION. OTHER REQUIREMENTS HAY APPLY. SPECIFICATIONS 8ND CONSTRUCTION DI8ORAtIS ARE AVAILABLE TO INSURE PROPER INSTALLATION. PERMIT EXPIRES DEC:EFIBER 31 ~ I_c~.78 I CERTIFY THAT 1: I AM FAtIILIAR WITH THE REQUIREMENTS FOR ON-SITE SELLERS ArID WELLS AS SET FORTH BY THE MUNICIPALITY OF ANCHORAGE. 2: I WILL INSTALL THE SYSTEM IN ACCORDANCE WITH THE CODES. ~: I UNDERSTAND THAT THE ON-SITE SELLER SYSTEM MAY REQUIRE ENLARGEMENT IF THE RESIDENCE IS REMODELED TO INCLUDE MORE THAN ~ BEDROOMS. APPL~4~NT ~.ISA MILLER V-?... 2 CONSULTING ENGINEERS AND SURVEYORS November 11, 1976 Eileen M. Schneiter & Bob Dalzell .. Box 3001 Anchorage, Alaska 99501 Re: Subsurface Investigation Proposed Subdivision %.:est of Birch Road Dear Mrs. Schneiter & Mr. Dalzell: This report presents the results of our soil investigation for the proposed subdivision of a 30-acre tract located west of Birch Road. The investigation was conducted on November 2 and 3, 1976. The results of that investigation are included in this report as follows: Vicinity Map Test Hole Location Sketch Idealized Soil Profiles Test Hole Logs (Sheets 1 through 14) .- Summary of Laboratory Test Data Standard Explanatory Information Drilling was accomplished utilizing a mobile drill B-50 mounted on a flex track Nodwell vehicle owned and operated by Denali Drilling; Inc. The test holes were logged and percolation tests conducted by our firm. Harding-Lawson & Associates performed the laboratory test data on ~rab samples taken during the drilling. The purpose of the investigation was to provide soils data for establishing the feasibility of on-site disposal of sanitary waste using seepage pits. To accomplish this, we drilled 14 borings distributed across the site as shown on the test hole location sketch. All borings were drilled to a depth in excess of 15'. During the drilling, our engineer was present to log the materials encountered and obtain grab samples of the soil types encountered. All soils were 9isually classified in the field in accordance'with the unified soil classifications system as described herein. GORDON O. UNWIN, P.E. LEO $CHEBEN, JR., I~E.,L.$. EARL PROJECT TEST HOLE NO. 2-9 CLIENT ELEV. TOP OF HOLE 478+ W.O. DATE 11/3/76 SHEET 6 OF. 14 18" Organic Silty Sand (OL) Damp, Brown, Gravelly Sand (SW) 2-9 (1.) (12.2% Silt)- " 2-9 (2) Bottom, Dry llole Municipality of Anchorage Development Services Department Building Safety Division On-Site Water and Wastewater Program 4700 Elmore Street P.O. Box 196650 Anchorage, AK 99519-6650 www.muni.org/onsite (907) 343-7904 CERTIFICATE OF ON-SITE SYSTEMS APPROVAL FOR A SINGLE FAMILY DWELLING Parcel I.D. OI5.- 2.~11- '~1 1. GENERAL INFORMATION Complete legal description Location (site address) IOI COSA# ! 0 Expiration Date: Current Property owner(s) Mailing ~ddress Lending agency Day phone Day phone 'zzz- 3'{53 Mailing address Real Estate Agent Day phone Mailing Address Unless otherwise-requested,-COSA will be held by DSD for pickup. NUMBER OF BEDROOMS: ~ TYPE OF WATER SUPPLY: Individual Well ..................... [] .......... Individual On:site Individual Water Storage [] Individual Holding Tank Community Class ~Well [] Community On-site Public Water System [] Public Sewer TYPE OF WASTEWATER DISPOSAL: The Municipality of Anchorage Development SerVices Department (DSD) issues Certificates of On-Site Systems Approval (COSA) based only upon the representations given in paragraph 4 by an independent professional civil engineer registered in the State of Alaska. Certificates of On-Site Systems Approval are required for the transfer of title (except between spouses) for properties served by a single-family on-site wastewater disposal and/or water supply system. DSD also issues COSAs upon request to homeowners. Certificates of On-Site Systems Approval are valid for 90 days from the date of issue for properties served by a private or Class C well and may be reissued with new water sample results, (Certificates may be reissued for a period of up to one year with valid water samples.) Certificates are valid for one year for properties served by Class A or B wells or a public water system. The Municipality of Anchorage is not responsible for errors or omissions in the professional engineer's work. 4. STATEMENT OF INSPECTION BY ENGINEER As certified by my seal affixed hereto and as of the validation date shown below, I verify that my investigation, based on procedures outlined in the Certificate of On-Site Systems Approval Guidelines for this application, shows that the on-site water supply and/or wastewater disposal system is (are) safe, functional and adequate for the number of bedrooms and type of structure indicated herein. I further verify that based on the information obtained from the Municipality of Anchorage files and from my investigation and inspection, the on-site water supply and/or wastewater disposal system is(are) in compliance with all applicable Municipal and State codes, ordinances, and regulations in effect at the time of installation. Name of Firm L 3,m S.~ur~l ~n~ Address ~0~ ~J. ~S~Av~. 5~, '/_o?.. An,~,~'~,. AK Engineer's Printed Name L A~s ,~'e~¢,,.,~, J ' 5. DSD SIGNATURE ~ Approved for ~ bedrooms. Disapproved. Conditional approval for bedrooms. ~th the following stipulations: By: Attachments: COSA Checklist Septic System Advisory Well Flow Advisory Nitrate Advisory X Arsenic Advisory Maintenance Agreements Supplemental Engineer's Report Other Original Certificate Date: J"?/ -//-- t/ ~ Municipality of Anchorage Development Services Department Building Safety Division On-Site Water & Wastewater Program 4700 Elmore Street P.O. Box 196650 Anchorage, AK 99519-6650 www.muni.org/onsite (907) 343-79O4 CERTIFICATE OF ON-SITE SYSTEMS APPROVAL CHECKLIST Legal Description: D~¥z¢ll - 5¢t~fl.~,'t~¢~ ~tl,~"Z ~' (~ Parcel ID: OJ5 - A. WELL DATA Well type Date completed Total depth ~ ~' ft. IfA, B, or C provide PWSID if Sanitary seal (Y/N) Casedto ~' ft. FROM WELL LOG Dateoftest . , Static water level U I~ ~ ~ r~ ft. Well production '-~ g.p.m. WATER SAMPLE RESULTS: Coliform ~:~ colonies/100mL Nitrate .~,~/ mg/L Arsenic: ~ 5,o0 ug/L date of sample: 312/2o~o SEPTIC/HOLDING TANK DATA TankType/Materlal 6rear' /Sf{fl Tank size 10~ gal. Foundation cle~nout (Y/N) Date of pumping -3121 20,0 C. ABSORPTION FIELD DATA Number of Compartments · Depression over tank (Y/N) Pumper ,At. ~c,R~ Well Log (Y/N)' Y Wires properly protected (Y/N) Casing height (above ground) In. Elapsed Time: ~5 min. Final fluid depth Lift in. Absorption rate >= ! q~) Any rejuvenation treatment (past 12 mo.) (YIN & lype) /~on~ ~o~ ~ If yes, gi'~e dale Length 33 ft. Width 7- I1~, ~ ft. Total depth (~,"{' ft Eft. absorption area ~ ~ ft=~ Monitoring tube. "~ Depression over field Dateofadequacytest ~tZl"ZotO Results(Pass/Fail) Pq% For:~ bedrooms Fluid depth In absorption field before lest '~} In. Water added HSO gal. i New depth g.p.d. Other bacteria . Cleanouts (Y/N) r : High water alarm ~/N) System type~ ~ ft. Gravel ~I~ pi~ g.p.m. '~'~ ' colonies/100 mL D. LIFT STATION Date installed ,/ Size in gallons · 'Pump on' level/a/ in. 'Pump off level at.._.~. / Datum ./ Cycles tested ./ E. SEPARATION DISTANCES Manhole/Access (Y/N) High water alarm level at Meets alarm & circu'_d4~e~uirements? in. SEPARATION DISTANCES FROM WELL ON LOT TO: Septic tank/lift station on let Absorption field on lot JOO Public sewer main Sewer/septic sen/ice line Animal containment areas 50' + On adjacent lots On adjacent lets Public sewer manhole/cleanout Holding tank Manure/animal excrete storage areas SEPARATION DISTANCES FROM SEPTIC/HOLDING TANK ON LOT TO: Building foundation. Water main ~O~+ Wells on adjacent lets ~; I+. Prope~y line Water sen/ice line ! I00 4- Absorption field. Surface water SEPARATION DISTANCE FROM ABSORPTION FIELD ON LOT TO: Property ine. Water Service line Curtain drain /V, O, F. COMMENTS Building foundation Surface water too Wells on adjacent lots Water main I O ~ '¥ Driveway, pa~ing/vehide storage I O ~ ¥ G. ENGINEER'S CERTIFICATION I cerfify that I havo determined through field inspections and review of Municipal records that the above systems are in conformance with MOA COSA guidelines in effect on this date. Engineer's Printed Name Date COSA Fee $ ~0 eo .. Date of Payment 3/3o [ ?..o ID Receipt Number OSa ~3r (Rev. 11/05) Waiver Fee $ Date of Payment Receipt Number Municipality Of Anchorage Development Services Department Building Safety Division On-Site Water and Wastewater Program 4700 South Bragaw St. P.O. Box 196650 Anchorage, AK 99519-6650 www.ci.anchorage.ak.us (907) 343-7904 CERTIFICATE OF HEALTH AUTHORITY APPROVAL FOR A SINGLE FAMILY DWELLING I arcel Expiration Date: 1. GENERAL INFORMATION Complete legal description . Lot 9, Block 2, Dalz..ell Schnelter Subdivlslon Location (site address or directions) 10121 Schneiter..Clrcle 0300 4 Current Property owner(s) Bill and Usa Miller Mailing address Lending agency Mailing address Real Estate Agent Mailing Address Unless otherwise requested, HAA will be held by DSD for pickup. NUMBER OF BEDROOMS: Three (3) Day phone .346-1164 1012t Schnelter Circle.. Anchorage, AK 99516 Day phone Dayphone 3. TYPE OF WATER SUPPLY: Individual Well Individual Water Storage Community Class Public Water System Well TYPE OF WASTEWATER DISPOSAL: [] Individual On-site [] Individual Holding tank Community On-site [] Public Sewer The Municipality of Anchorage Development Services Department (DSD) Issues Certificates of Health Authority Approval (HAA) based only upon the representations given in paragraph 5 by an independent professional civil engineer registered in the State of Alaska. Certificates of Health Authority Approval are required for the transfer of title (except between spouses) for properties served by a single family on-sita wastewatar disposal and/or water supply system. DSD also issues HAAs upon request to homeowners. Certificates of Health Authority Approval are valid for 90 days from lhe date of issue for properties served by a private or Class C well and may be reissued with new water sample results less than 30 days old. (Certificates may be reissued for a period of up to one year with valid water samples.) Certificates are valid for one year for properties served by Class A or B wells or a public water system. The Municipality of Anchorage Is not responsible for errors or omissions in the professional engineer's work. 4. STATEMENT OF INSPECTION BY ENGINEER As certified by my seal affixed hereto and as of the validation date shown below, I verify that my investigation, based on procedures outlined in the Health Authority Approval Guidelines for this application, shows that the on- site water supply and/or wastewatar disposal system is(are) safe, functional and adequate for the number of bedrooms and type of structure indicated herein. I further verify that based on the information obtained from the Municipality of Anchorage files and from my investigation and inspection, the on-sita water supply and/or wastewater disposal system is(are) in compliance with all applicable Municipal and State codes, ordinances, and regulations in effect at the time of installation. Name of Firm Anderson Englneerin,q , Address P.O. Box 240773 Anchorage, .AK 99524 Engineer's Printed Name Michael E. Anderson, P.E. DSD SIGNATURE Approved for Disapproved. Conditional approval for bedrooms. Phone 522.7773 Date 3fl712003 bedrooms, with the following stipulations: Additional Comments Attachments: HAA Checklist Septic System Advisory Well Flow Advisory X Maintenance Agreements Supplemental Engineer's Report Other (Rev. 12/00) Odginal Certificate Date: Municipality of Anchorage Development Services Department Building Safety Division On-Site Water & Wastewater Pmgram 4700 South Bragaw St. P.O. Box 196650 Anchorage, AK 99519-6850 www.ci,an~orage.ak.us (907) 343-7904 HEALTH AUTHORITY APPROVAL CHECKLIST Legal Description: Lot 9. Block 2, Pal=ell Schnelter Subdiv!stoq A. WELL DATA Well type Private Date completed 8/26/1678 Total depth 87 fl. IfA, B, or C provide PWSID ft , Sanitary seal ~/N) Y Cased to, 87 fl. FROM WELL LOG , 8~r~lg?S Uqknown fl. Date of test Static water level Well production g.p.m. WATER SAMPLE RESULTS: Coliform 0 colonies/100 mi. Date of sample: 3/10/2003 B. SEPTIC/HOLDING TANK DATA Tank Type/Material .$eptictSteel Tank size 1,<100 gal. Foundation cleanout (Y/H) :~ Date of pumping _3/10/2003 C. ABSORPTION FIELD DATA Nitrate .3. mg./I. Collected by: A. Harala Number of Compartments 2 Depression over tank (Y/N) _N Pumper isaacs Parcel ID: 035-291:21 Well Log (Y/N) y, Wires pmpedy protected (Y/N) y Casing height (above ground) >24 . in. AT INSPECTION . 3/7/2O03 · ,SO,2 ft. · 6,7.4 g.p,m. Other bacteria ,9. colonies/100 mi, Date installed 9/2011978 Cleanouts (Y/N) y High water alarm (Y/N) For 3_ bedrooms g,p.d. If yes, give date Date installed 9/20/1978. Soil rating (g.p.d./fl2 or fl2/bdrm) 125_ sF/BDRM System type Deep Trench Length .33 fl. Width ~8 fl. Gravel below pipe 6 Total depth 10 fl. Eft, absorption ama 396 fl2 Monitoring tube Y Depression over field N Date of adequacy test 3/'f120p3 Results (Pass/Fail) Pass Elapsed Time: 1.440 min. Final fluid depth 39 in. Absorption rate >= Any rejuvenation treatment (past 12 mo.) (Y/N & type) N LIFT STATION Date installed 'Pump on" level at Datum E. SEPARATION DISTANCES Size in gallons "Pump off" level at ~ Cycles tested SEPARATION DISTANCES FROM WELL ON LOT TO: Septic tank/lift station on lot. 96~ Absorption field on lot >100' Public sewer main NIA Sewer/septic service line >25' in. Manhole/Access (Y/N) High water alarm level at Meets alarm & circuit requirements? On adjacent lots >100' On adjacent lots >100' Public sewer manhole/cleanout N/A Holding tank NIA SEPARATION DISTANCES FROM SEPTIC/HOLDING TANK ON LOT TO: Property line ...>5,. Water service line. ~10' Building foundation >5' Water main >1.0' Wells on adjacent lots >100' SEPARATION DISTANCE FROM ABSORPTION FIELD ON LOT TO: Property line >10' Building foundation >10' Water Service line >10' Surface water >1.00' Curtain drain None Noted Wells on adjacent lots >100' COMMENTS *' See Well to Seotic Tank Wa'n/er ENGINEER'S' CERTIFICATION I certify that I have determined through field inspections and review of Municipal records that the above systems are in conformance with MOA HAA guidelines in effect on this date. Engineer's Printed Name Michael E. Anderson. Date 7/3/2003 Absorption field >5' Surface water >100' Water main >10' Driveway, parking/vehicle storage >25' Waiver Fee $ Date of Payment Receipt Number HAA Fee $ Date of Payment ~ Receipt Number (Rev. 1 in. Al. ~D o. ~7: O0 "~. ./ I ~tOO D v co,Jo.. P,~T~JIVIt,16 ANDERSON ENGINEERING P.O. BOX 240773 ANCHORAGE, AK 99524 522-7773 522-6779 ,(FAX) July 3, 2003 Municipality of Anchorage Building Safety Division On-Site Water and Wastewater Program 4700 S. Bragaw Street Anchorage, AK 99507 Subject: Lot 9, Block 2, Dalzell Schneiter Subdivision Separation Distance Waiver Septic Tank to Well Dear On Site Services Engineer: The septic tank on Lot 9, Block 2, Dalzell Schneiter Subdivision was originally placed on the lot in 1978. Documentation completed at that time and a Health Authority Checklist completed in 1987 state the distance between the septic tank and the private well on the lot is 100'. A recent measurement, however, indicates the well is only 98.7' from the septic tank cleanout. We are therefore applying for a separation distance waiver allowing the septic tank to remain 96' from the well. The attached site plan shows the current configuration of the well and septic system on the lot. The well is located approximately 10' upslope from the septic tank with the surface drainage of the area from south to north at steep grades approximating 15%. Ail surface water drains swiftly away from the well. The soil on the lot is primarily a silty gravel, which percolates at between 6 and 15 minutes per inch. The absorption trench constructed in 1978 is still in fair condition and absorbs water at a rate faster than 450 gallons per day. The flow from the absorption pit appears to be in a northerly direction and away from the well following the surface slope of the area. The surface slopes at close to 10% away from the absorption pit on the north side of the property. It is highly unlikely any effluent escaping from either the septic tank or absorption trench would flow in the direction of the well. The log for the well indicates it is 87' deep. The static water level was recently measured at 50.2' below the surface. The log indicates a lense from 52' to 74' below the surface, which is either silt or silt with minor amounts of gravel. This lense should protect the aquifer from contamination from any surface water as it will slow or prevent percolation. We have evaluated the justification for a separation distance waiver based on ADEC guidelines. This evaluation is as follows: Lot 9, Block 2, Dalzell Schneiter Separation Distance Waiver July 3, 2003 Page Two Separation Distance Waiver Guidelines Water Table 40' Below Tank 5.0 Soil Type Sand & Gravel with Silt 2.5 Permeability Sandy Gravel with Silt 1.0 Water Table Gradient 10% 6.0 Horizontal Separation 96' 2.8 Total 17.3 The conclusion based on the aforementioned point totals is that almost surely no form of contamination can be expected from household sewage. It is therefore recommended the waiver be approved to allow the existing septic tank to be 96' from the existing well. A recent water sample taken from the well indicated an undetectable concentration of Nitrates. In addition, no coliform or other bacteria was found in the water. This compares with the sample taken in 1987. It is apparen{ that neither'the absorption trench nor the septic tank is influencing the quality of the water from the well. Sincerely, Michael E. Anderson, P.E. Attachments v h ZP. '":..'Y ', ... . ',J/:/,~~/C//")~. . . - e. ,. .....,-.,,o V.. 'o ~ ,~. ~e~,~.gnslhllity to d0tefmP~e tho ~2~ "~ .."'~'~ ~ or restrictions which do not appear Sh'~% ~.. ......... .,~ ~__,.,- l~e0n be u~ for ~ns~on 0r ~ ENGINEERS · PLANNERS - SURVEYORS 440WEST BENSON BLVD. ANCHORAGE, ALASKA 99503 562-5291 LEGAL DESCRIPTION: SURVEY CERTIFICATION: I hereby certify that I have surveyed the property shown Icflbed hereon end that the Improvements situated thereon ere within the property lines encroachments exist other than noted. PLEASE NOTE: It Is the contract -or'~ responsibility to check top of · foundation In relation to finish grade end building let- backs In relation to lot lines LEGEND: SET FOUND 5/8" REBAR · 0 HUB & TACK MONUMENT AL-CAP ~ (~) PK NAIL X IRON PIPE - (~ ' I'ELEVS.-DATUM ASSUMED Municipality of Anchorage Development Services Department Building Saf~y Division On-Site Water and Wastewat~ Pwgram 4700 Bragaw Street P.O. Box 196650 An~orage, AK 99519-6650 www. ci.anchorage.ak.us (907) 343-7904 Waiver Review Worksheet WRg: 030052 PID~: ~)t5-291o21 HAg: Permitg: Date Received: 7/3103 Legal Description: Dalzell $ohneiter Engineer:. Anderson Enulneerinu Applicant: Mike Anderson Waiver Requested: 96, septic tank to well eeperation distance Criteria: Geology A. Water Table B. Soil Sorption C. Permeability D. Water Table Gradient E. Horizontal Separation Points: Total: Waiver is Granted: Waiver Is not Granted: List Conditions or Reasons for above: ' I Name of Reviewer Rec~: 37981 Amount: $800 Date Paid: 711012003 ~f.~- /(e,)e.. 7'l~e ~o;I o,v tlc z,,/- ;s /or~M.~;/y 2;~//n, ~o~c/. -- 7'-a,v'l,-.- D~ 4n --- ~ (so 'l ?il ~o.z..) -II + E- · ALASKA ENVIRONMENTAL CONTROL SERVICE-e-,INC. 1200 West 33rd Avenu~ ;uite B ANCHORAGE, ALASKA 99503 (907) 561-5040 JOB SHEET NO, CALCULATED BY CHECKED BY SCALE DATE DATE MUNICIPALITY OF ANCHORAGE DEPARTMENT OF HEALTH & HUMAN SERVICES DIVISION OF ENVIRONMENTAL SERVICES CERTIFICATE OF INSPECTION FOR HEALTH AUTHORITY APPROVAL OF ON-SITE SEWER AND WATER FACILITY 264-4744 Application Date ,~.h ~>/~ GENERAL INFORMATION (MUST BE COMPLETED PRIOR TO SUBMI~AL) Descr~tion (include I~t. block, ~u~division, jectioD, township, range)_ Location (address or direction~ (b, Prope~;w~e; ~/~ ~~Teleghone:Home.~usiness~ Mailing Address (d),, AddressReal Estate Company.. .and Agent Telephone (e) Mail the HAA to the followino address: or. Check here I-I, if hold for pick up. List contact.person and day, phone number below. TYPE OF RESIDENCE Single-Fam. ily j~' Number of Bedrooms WATER SUPPLY Individual Well~) Community I-] Public Note: If community well system, must have written confirmation from the State Department of Environmental Conservation attesting to the legality and status. SEWAGE DISPOSAL Onsite~ Public I"3 Community [] Holding Tank [] Note: If community well system, must have written confirmation from the State Department of Environmental Conservation attesting to the legality and status. ENGINEERING FIRM PROVIDh.. INSPECTIONS, TESTS, FILE SEARCH, DA I A AND INFORMATION As certified by my seal affixed hereto and as of the validation date shown below, I verify that my investigation of this Health Authority Approval shows that the on-site water supply and/or wastewater disposal system is safe, functional and adequate for the number of bedrooms and type of structure indicated herein. I further verify that based on the information obtained from the Municipality of Anchorage files and from my investigation and inspection, the on-site water supply and/or wastewater disposal system is in compliance with all Municipal and State codes, ordinances, and regulations in effect on the date of this inspection. AN:~lr~iO~ Firm ...... _ Date ~ DHHS APPROVAL Approved for ~'/""'"~'Cf'~,,) bedrooms by ~ '~:?' "~ Approved ~ Disapproved Conditional Terms of Conditional Approval CAUTION The Municipality of Anchorage Department of Health and Human Services {DHHS) issues Health Authority Approval certificates based only upon the representations given in paragraph 5 above by an independent professional engineer registered in the State of Alaska. The DHHS does this as a courtesy to purchasers of homes and their lending institutions in order to satisfy certain federal and state requirements. Employees of DHHS do not conduct inspections or analyze data before a certificate is issued. The Municipality of Anchorage is not responsible for errors or omissions in the professional engineers work. Page 2 of 2 ?2-~s m~, ~,86~ SAck MUN,CIPAUT OF ANCHORAGE DEPARTMENT OF HEALTH AND ENVIRONMENTAL PROTECTION DIVISION OF ENVIRONMENTAL HEALTH CERTIFICATE OF INSPECTION FOR HEALTH AUTHORITY APPROVAL OF ON-SITE SEWER AND WATER FAClLI~ 264~720 Application Date GENERAL INFORMATION (a) Legal Description (include lot. block, subdivision, section, township, range) Location (address or ~irections) (b) Applicant Name ~_~,fA }-~/4~[~.~' Telephone: Home ~/("° ~/~"~" Business Applicant Address ,/'~/~'/ -~'~'/'/'~'~7~'~' ~/~" ,~.~ ,,~'. (c) Applicant is (check one): Lending Institution I-I; Owner/builder'S; Buyer []; Other [] (explain); (d) Lending Institution /'~'~'W/~t7~'~v//y~- z~,.~.~'~' Telephone Address (e) Real Estate Company and Agent Address Telephone (f) Mail the HAA to the following address: TYPE OF RESIDENCE Single--Family~' Multi-Family [] Number of Bedrooms '~ Other WATER SUPPLY Individual Well']~. Community [] Public [] Note: If community well system, must have written confirmation from the State DePartment of E. nvironmental Conse,rvation attesting to the legality and status· "' ' ', , SEWAGE DISPOSAL Onsite/~[~. Public [] Community [] Holding Tank Note: If community well system, must have written confirmation from the State Department of Environmental Conservation attesting to the legality and status. Page I of 2 72-025 ENGINEERING FIRM PROVIDING INSPECTIONS, TESTS, FILE SEARCH, DATA AND INFORMATION As certified by my seal affixed hereto and as of the validation date shown below, I verify that my investigation of this Health Authority Approval shows that the on-site water supply and/or wastewater disposal system is safe, functional and adequate for the number of bedrooms and type of structure indicated herein. I further verify that based on the information obtained from the Municipality of Anchorage files and from my investigation and inspection, the on-site water supply and/or wastewater disposal system is in compliance with all Municipal and State codes, ordinances, and regulations in effect on the date of this inspection. Name of Firm Telephone Address /~/~ ./,J ...~.~1~ ~.~,~c~ ~'lil,t~'~ ,~ 6o Approved for ~ bedrooms by _/_ · ~ D~ v~-'d Conditional Terms of Conditional Approval ~J ~/~ ~ CAUTION The Muncipality of Anchorage Department of Health and Environmental Protection (DHEP) issues Health Authority Approval certificates based solely upon the representations given in paragraph 5 above by an independent professional engineer registered in the State of Alaska. The DHEP does this as a courtesy to purchasers of homes and their lending institutions in order to satisfy certain federal and state requirements. Employees of DHEP do not conduct inspections or analyze data before a certificate is issued. The Municipality of Anchorage is not responsible for errors or omissions in the professional engineer's work. Page 2 of 2 ~' A. WELL DATA MUNICIPALITY OF ANCHORAGE (MO~:~ MUNIO~ALr~ OF Ai'.,~,O~¢~.~. ~ SERVIC~S D~ AUTHORITY APPROVAL (~) E~I~ CHECKLIST - FEBRUARY 19M 2 6 1987 RECEIVED Well Classification Well Log Present'N) Total Depth fi' Static Water Level ~),E/~,~-7~- If A, B, C, D.E.C. Approved (Y/N) Date Completed ~'~°~' -' ? ~' Yield Cased to 3' ~' · Depth of Grouting ~',','/;P- ~' ' Pump Set At Casing Height Above Ground Electrical Wiring in Conduit (Y~) Separation Distances from Well: To Septic/Holding Tank on Lot To Nearest Edge of Absorption Field on Lot To Nearest Public Sewer Line Cleanout/Manhole Sanitary Seal on Casing~l) .~z'-z" d~//yz.,/x'$ ~ Depression Around Wellhead (Y~ Water Sample Collected by /'~'-E ~ ; Date Water Sample Test Results Comments ~z~ ~',J4-Z'_t /z:.~.J /P~'~ ; On Adjoining Lots /~"~'~ '~ //~'" ; On Adjoining Lots /~'~ '~' To Nearest Public Sewer / To Nearest Sewer Service Line on Lot ~--5' -~' B. SEPTIC/HOLDING TANK DATA Date Installed Standpipes~N) Depression over V Pumping/Maintenance Contract on File (Y/N) Holding Tank High-Water Alarm (Y/N) Separation Distances from Septic/Holding Tank: To Water-Supply Well To Property Line To W;ter Main]Service Line Size /~''//C~ No. of Compartments ~"~' Air-tight Caps(~) Foundation Cleanou~N) Date Last Pumped ; for Temporary Holding Tank To Building Foundation To Disposal Field Permit (Y/N) ,4///,~ Course To Stream, Pond, Lake, or Major Drainage Comments';~,,J~/7~,,~,w.- '73 ,~/z~ ~z,P~'.~$.</~,./ Ix/ $,,~,/~ If,Y?. Pagelof2 . ' :. : 72-026[11/84) C, ABSORPTION FIELD DATA Soils Rating in Absorption Strata Date Installed ~- 2o - ?~" Width*of Field ,.~ · ~' Square Feet of Absorption Area -'~ ')~' ~ Depression over Field (Y~ Results of Last Adequacy Test ./~'~'/~ 7~E' ,--'"'" Separation Distance from Absorption Field: To Water-Supply Well //~-- · To Building Foundation _.T~ Lot To Water Main/Service Line To Stream/Pond/Lake/or Major Drainage Course To Driveway, Parking Area, or Vehicle Storage Area Comments Type of System Design Length of Field Depth of Field Gravel Bed Thickness Standpipes Present) Date of Last Adequacy Test To Property Line 7~' To Existing or Abandoned System on ; On Adjoining Lots To Cutbank (if present) /',/'/,,~ LIFT STATION Date Installed~'-,.~ Size in Gallons --.,. "Pump On" Level at High Water Alarm Level at Tested for Electrical Codes (Y/N). Comments Dimensions Manhole/Access (Y/N) "Pump Off" Level at Vent (Y/N) ~~les during Adequacy Test. Meets MOA °* Check Permitted Bedroom Rating Against HAA Request ** I certify that I have phecJ~ed, ye{if ted. or conformed to all MOA and HAA guidelines n effect on the date of this inspection Signed ~'"~'° /~'CJ/~'''~ Date .~--,/'~ '°C7 Company /~r-~' ,< MOA No. Receipt No. ./(~ ('¢~/ Date of Payment "-2,/) ~'.~'.,~ , Amount: $ Page 2 of 2 SYREN BROS. / 2LLING, INC. 2701 EAGLE STREET ANCHORAGE, ALASKA 99503 274-6437 8-28-78 STATEMENT r,IR. & r, IRS. BILL ;,:ILLER 1200 WEST DI~.IOND BLVD. SP.# 10-14 ANCHORAGE, ALASKA 99502 cased hole $18.50 oer ft ...... · ~160~ .00 well seal N/C "drive shoe N/C . ~ ~"~.~ ~,o ?-. L~-'-~7~'~!'-_'~. , ~.T~.~:~~ ~.,,_ ~... ~,:~:~--_ . Redi~rms 8S872