Municipality of Anchorage
Development Services Department
On*Site Water and Wastewater Program
4700 South Bragaw Street
P.O, Box 196650 Anchorage, AK 99519-6650
www,d,anchorage.ak.us (907) 343-7904
ON-SITE WASTEWATER DISPOSAL SYSTEM AND/OR WELL INSPECTION REPORT
Permit Number: SW020043
MM&M ContractinR
P,O. Box 670495 ChuRiak, AK 99567
688-1236
Four (4)
LEGAL DESCRIPTION
Knik View Estates
Well: Community Water System
SEPARATION DISTANCES
Septic Absorption Uft
Tank Field Station
w. >200' >200' N/A
s~.w.,. >100' >100' N/A
>5' >10' N/A
F~,,~, >5' >3.0' N/A
None Noted
PID Number: 051-043-32
Wastewater System: New
Page 1 of 3
ABSORPTION FIELD
5' Wide Trench
1.2 c~o~ 8.5 ..
4.5 ~,. 4
· 5 n. 52 ~,.
5
520 re ASTM D~034 PVC
MM&M Contracting 3/30/02
TANK
Septic
LIFT STATION
Tank SewerUne Anchorage Tank
N/A >25' Steel
N/A ~
N/A
BENCH MARK
Finished Floor.
1,250
Two (2)
lO0.O FL
Inspections performed by: Tim Kimbrough Dates: 1" 3/30/02
2"d 3/30/02
Department of Health and Human Sen/ices approval
Reviewed and approved by:¢ ~ Date: ?
Engineer's Stamp
Municipality of Anchorage Page 2 of 3
DEVELOPMENT SERVICES DEPARTMENT
· 4700 South Bragaw Street Anchorage, AK 99519-6650 - 343-7904 ~
On-Site Wastewater Disposal System or Well Inspection Report
Permit Number SW020043 PID No. 051-043-32
RANKIN DRIVE
TIll
~ C4
Utility Easement'
Alternate Four
Site
Uome
_®
TB2 M1
A B
S1 53.7 37.7
S2 60.6 45.7
C4 63.7 68.5
M1 83.6 58.7
C5 84.9 58.9
$1
Line
/
Municipality of Anchorage
DEVEOPMENT SERVICES DEPARTMENT
4700 South Bragaw Street Anchorage, AK. 99519-6655 - 343-7904
On-Site Wastewater Disposal System or Well Inspection Report
Permit Number. SW020043
Legal Description: Lot 1, Block 4, Knik View Subdivision
BACKFILL
86.9-'~.00.,.. 4. 0
Page 3 of 3
PID No. 051-043-32
86.91
76.0
. ~eotextile
])coln¢ield Rock
BACKFILL
8~.49
86.95
$~.0o
PROFILE
Scole: 1" - 10'
AS-BUILT
NO. : 90",'68~1238 ~ul. 16 ~ 01:16PH P2
I hereby c~ t~. l,ba~e surveyed1 t~e ~oltow~$ d~
.... . .,. ~tk V~ .~ .
..... · . , ~;.,~ :~,~ ~ ~ - '::
~ .:~~~.~ .... ..... .
':L'~-":.'~Re~eived Time'Jul,lb, 12:4 PM ~ . ~g :..:.: ' -~~dS~o.~'.
:',.:,..., ',..~.;:, .: . . . . . '..,.~,:.',.....: .'-t .~o~~:., .. ,,..".;: .
MUNICIPALITY OF ANCHORAGE
Development Sen4ces Department
On-Site Water & Wastewater Program
4700 South Bragaw Street
P.O. Box 196050, Anchorage, AK 99519-6650
(907) 343-7904
ON-SITE WASTEWATER DISPOSAL SYSTEM PERMIT
Initial
Date Issued: Mar 27, 2002
Expiration Date: Mar 27, 2003
Permit Number: SW020043
Legal Description: KNIK VIEW ESTATES BLK 4 LT 1
Design Engineer: 0014 Anderson Engineering
Owner Name: MM&M Contracting
Owner Address: PO Box 670495
Chugiak, AK 99567-0495
, Parcel ID: 051-043-32
Site Address: 022738 JUDD DR
Lot Size: 21787 SQ. FT.
Total Bedrooms: 4 Permit Bedrooms: 4
This permit is for the construction of:
[] Disposal Field [] Septic Tank [] Holding Tank [] Privy
[] Private Well
[] Water Storage
All construction must be in accordance with:
1. The attached approved design.
2. All requirements specified in Anchorage Municipal Code Chapters 15.55 and 15.65'and the State of Alaska
Wastewater Disposal Regulations ( 18AAC72 ) and Drinking Water Regulations ( 18AAC80 ).
3. The engineer must notify DSD at least 2 hours prior to each inspection. Provide notification by calling
(907) 343-7904 ( 24 hours ). ( Not required for a Water Supply Permit only ).
4. From October 15 to April 15, a subsurface soil absorption system under construction during freezing weather
must be either: A. Open and closed on the same day.
B. Covered, sealed, and heated to prevent freezing.
Municipality of Anchorage
Development Services Department
Building Safety Division
On-Site Water and Wastewater Program
4700 South Bragaw St.
P.O. Box 196650 Anchorage, AK 99519-6650
www.ci.anchorage.ak.us
(907) 343-7904
ON-SITE SEWER/WELL PERMIT APPLICATION
FOR A SINGLE FAMILY DWELLING
Parcel I.D. 051.043-32
Permit Number SW
Pmperb/owner(s) MM&M Contractin¢l
Day phone 688.1236
Mailing address (1) P.O. Box 670495 Chu.qlak, AK 99567
Mailing address (2)
Zip Code
Legal description (Lot, Block & Sub'd.) Lot 1, Block 4, Knik View Estates Subdivision
Legal description (Section, Township & Range)
2 I, 7 '7 Acres .
Lot
Size
Number of Bedrooms Four
THIS APPLICATION IS FOR:
Sewer Only
Sewer and Well
Sewer Upgrade
THIS PROPERTY CONTAINS:
Hot Tub
Swimming Pool
Therapy Pool
Well Only
Water Storage
Jaouzzi
Water Softening Unit
I certify that the above information is correct. I further certify that this application is being made for a
Single Family Dwelling and is in accordance with applicable Municipal Codes.
(Signature of property owner or authorized ageht)
Number:
· oc::, ': Waiver~ Fees:
'~O'""~9 - ~ ~ - -,~ Date of Payment
~E) ~' ~-c~ .~ Receipt Number:
March 5, 2002
Municipality of Anchorage
Development Services Department
On-Site Water and Wastewater Program
4700 South Bragaw Street
Anchorage, AK 99519-6650
Subject:
Lot 1, Block 4, Knik View Estates Subdivision
Septic System Design and .P, ermit Application
Impacts to Adjacent Properties
Dear Onsite Services Engineer:.
.The owner of Lot 1, Block 4, Knik View Estates Subdivision intends to construct a new
four-bedroom home on the lot. We are therefore requesting a permit be issued for the
construction of a new septic system to serve the proposed home. The attached Site
Plan and backup documentation Identify the location and configuration of the new
septic system and the parameters used in the design. Also identified on the plans are
the location of the water service line on the lot and the test hole locations along with the
septic systems located on nearby lots. Existing drainage patterns are shown and will
not be altered by the development of the lot.
Two test holes were placed near the location of the proposed absorption trench. These
test holes indicate clean well-graded gravel with varying amounts of sand near the
location of the new absorption trench. Percolation tests in the material resulted in rates
of less than 1 minute per inch. No groundwater was found during the placement of the
test holes and none was noted during the monitoring period. We are therefore
proposing to place a 5' wide shallow absorption trench system with 4' of gravel beneath
the distribution pipe. The total depth of the trench will be 7.5'. The distribution pipe will
be placed at 3.5' below the ground surface to provide sufficient drop from the septic
tank to the absorption trench. The total length of the new absorption trench will be 50'.
The ground surface on the lot slopes as shown on the attached Site P.!an with very, little
to no slope near the proposed septic system site. The new absorption trench w~ll be
'constructed on a fairly flat surface in conformance with Municipal requirements and
parallel to ground contours where possible. All components of the new septic system
will be constructed a minimum of 10' from the water service on the lot.
If the system Is constructed In accordance with our design the following statements
apply:
The system, if constructed as designed, will have no adverse impact on the wells
in the area or those to be constructed In the future. The subdivision is currently
served by a community water system.
Lot .1, Bl(~ck 4, Knlk View Estates Subdivision
·. 'March 5, 2002
Page Two
2. The system, if constructed as designed, will have no adverse impact on existing
septic systems In the area or those to be constructed in the future.
3. The system, if constructed as designed, will have no adverse impact on reserve
space, either surface or subsurface, on any lots located In the area.
4. The system, if constructed as designed, will have no adverse.impact on drainage
patterns in the area. The current drainage pattern will be maintained.
Sincerely,
Michael E. Anderson, P.E.
Attachments
170.00 85-11~
THIS PROJECT
17932
· '~ VACANT
.o_~ ~ " .,:'.
WCS1 179.26
/
/
I
/
I
I
I
/
I
I
I
/
/
JUDD Circle
mo.oo
.5~.~.
R^NKIN .,
27
\
\
\
I
I
3
/
/
2/
/9
/8
/3
$75.~O
50.00 205.00 w£$'
/7
· AREA SYSTEM PLAN ..
SCALE 1" = 100'
No. C[-4381
.l
RANKIN DRIVE
0% - 1%
Alternate
Site
0% 1%
TH1
TH2
Utility Easement
~--~,- 1% 10'
I ~ Four
., ~--~ ~ Bedroom
Home
1,250 Gallon
Septic Tank
50' Long X 5' ~
Wide X 4' Eff.
~-_Depth_Absorption
Trench
~ Water Serv:[ce //~ _~ /
/
SITE PLAN
' SCALE 1" = 30'
LOT 1, BLOCK 4, KNIK VIEW ESTATES
SUBDIVISION
DESIGN FACTORS:
SYSTEM REQUIREMENTS:
Four Bedroom Home
Perm Rate: <1 Min./Inch
Application Rate: 1.2 GPDISF
5' Wide Trench System
.250 Gallon Septic Tank
4' Dralnfleld Rock
4 Bedrooms X 150 GPD 11.2 GPD/SF = 500 SF of Absorption Area
500 SFI5 LF (Width)*.5 (Red. Factor) = 50 LF Trench Length
Therefore: Construct a 50' Long X 5' Wide X 4' Effective Depth Absorption Trench.
Flowline Elevation In Trench to be 3' Below Original Ground Surface. Total Depth to be 7'
Below Existing Ground. Mound Over Trench to Provide a Minimum of 3' of Cover or
Provide 2" of Direct Bury Insulation and 2' of Cover.
,,//,,,%///~.~//~ Natural Backf
~ ( 3 ' Minimum' ~
3 ' ,,
Geotextile
Fabric
· '/ 4" PVC
4 ' % (Roles Down)
~ Dratnfteld
~ / ~ . t~ock
..-
.'-": :, ' · .' . ~PICAL WIDE TRENCH SECTION': '
NOTE.. .~ Grade Area Over Trench to Drain Away ....... [ ~.. ~,.... ~, ~-~.
.: ' .?.~ ',' Minimum 6' Secretion From B~roc~ ."-' :~ ~' '~J'. /:
, ~':'~.~::" C ~" ~ : Minimum 4' Separation From Groundwater.:" ~ ,:..,. ~;, ~: ~"
:-".'-~ ..<'.'.-~,:~[ ,.'Minimum 10' Secretion From Water Se~tc~ Liner:. ~ '~;' i: T: ~:*~ ~,~. ~:~ .
· .--)'~ ~.~.,,~, .: . ,. ', .- ' ,,r" · + ~ . ' · ,:,-' ',.,J~'.,~'. ~,' /.~
PROJECT #:
PERFORMED FOR:
Municipality of Anchorage
Development Services Department/On-Site Water and Wastewater Program
4700 South Bragaw Street, Anchorage, AK 99516-6650
- - SOILS LOG - PERCOLATION TEST.
HM~.M I'ON~TRUCTION / PAUl HYER~, DATE PERFORMED:
LEGAL DESCRIPTION:
I OT 1 BLOCK ~, KNIK V1FW SUBD
10--1
II --I
I
12 I
TEST HOLE # 1
OG / BROWNISH SILTY-SANDY-GRAVELS
SLIGHT DENSITY / WELl. GRADED
SANDY GRAVELS - GW
SLOPE
0%
WAS GROUNDWATER
ENCOUNTERED~ NO S
L
IF YES, WHAT DEPTH? O
P
DEPTH OF WATER J~JoJl. e
AFTER MONITORING: E
DATE: 2/28/02
SITE PLAN
1"=100'
0%
~5
16--
17~
MEDIUM DENSITY / SILTY-SANDY-
READING
GRAVELS
Start
1
.,.. Recharge
~"~ 49th ~ ~ ~' $ Recharge
PERC R~TE: - 1
TEST R~ BETWEEN
DATE ' GROSS NET DEPTH OF NET
T~ME TIME WATER DROP
2116102 1/.:00 12"
1/.:02 2 12"
1/.:03 12"
1~,:05 2 12"
1/.:06 12"
1/.:08 2 12"
MIN./INCH PERC. HOLE DIAMETER: 6"
3.~ FT. AND /..5 FT.
COMMENTS:
NO IMPERMEABLES ENCOUNTERED / HOLE PRESOAKED PRIOR TO TEST
TEST PERFORMED BY: T.L. K~MB~'OUGH I, M,CHAEL E. ANDERSON, CERTIFY THAT TH~S TEST WAS PERFORMED IN ACCORDANCE
WITH ALL STATE AND MUNICIPAL GU:DELINES ON THIS DATE:
Municipality of Anchorage
Development Services DepadmentJOn-Site Water and Wastewater Program
4700 South Bragaw Street, Anchorage. AK 99516-6650
.......... SOILS LOG - PERCOLATION TEST_____._-
PROJECT'#: t~o?o'7 .... '
PERFORMED FOR: HH&H C0N~TRUCT~gN / PAUl HYERS DATE PERFORMED:
LEGAL DESCRIPTION:
LOT 1 BLOCK/. KN[K VIEW SUBD
I
I
I
12
TEST HOLE # 2
OG / BROWNISH SILTY-SANDY-GRAVELS
SLIGHT DENSITY / WELL GRADED
SANDY GRAVELS - GW
SLOPE
WAS GROUNDWATER
ENCOUNTERED') NO
0%
IF YES, WHAT DEPTH',~
DEPTH OF WATER ~lol'te
AFTER MONITCRING:
DATE: 2/28102
S
L
0
P
E
SITE PLAN
1"=100'
0%
15
17--
18
HEDIUH DENSITY / SILTY-SANDY-
READING DATE
GRAVELS
Start 2/16/02
1
GROSS NET DEPTH OF NET
TIME TIME WATER DROP
1/*:25 12'
1/.:26 1 12"
1/.:27 12"
1/.:28 1 12"
1/.:29 12"
1/.:30 1 12'
MIN./INCH PERC. HOLE DIAMETER: 6'
35 FT. AND .../..S FT.
COMMENTS:
NO IMPERHEABLES ENCOUNTERED / HOLE PRESOAKED PRIOR TO TEST
TEST PERFORMED BY: T.L. KIMSROUGH I, MqCHAFI E. ANDERSON, CERTIFy THAT THIS TEST WAS PERFORMED IN ACCORDANCE
WITH ALL STATE AND MUNICIPAL GUIDELINES ON TH:S DATE:
ON-SITE WASTEWATER DISPOSAL SYSTEM
CONSTRUCTION AND MATERIAL SPECIFICATIONS
SUBJECT: LOT 1, BLOCK 4, KNIK VIEW ESTATES SUBDIVISION
GENERAL:
The scope of this project includes the procurement and placement of a
new 1,250 gallon septic tank at the location shown on the Site Plan.
Work also includes the construction of a new 50' long X 5' wide X 4'
effective depth absorption trench at the location also shown on the
Site Plan. The distribution line in the trench will be placed at 3.5'
below the existing ground surt'ace. Total depth of the trench will be
7.5' below the existin, g ground surface. The new absorption trench
must be placed a minimum of 10' from the water service on the lot.
Construction shall be in accordance with the approved site plan,
design drawings, Municipal Permit with any special provisions or
conditions, and all applicable State and Municipal Wastewater
Disposal Regulations.
The Contractor shall be responsible for obtaining all underground utility
locates and for the layout of the septic system and verification of the
location of all lot lines.
Unless specifically agreed otherwise, the contractor shall be
responsible for final grading areas subsequently depressed from soil
settling. Property owner shall be responsible for revegetation of
affected areas unless specifically agreed otherwise.
Contractors installing wastewater disposal systems must be certified
by the Municipal Department of Health and Human Services for
system installations. Owners installing their own systems must receive
pdor approval from D.H.H.S. before beginning system installation.
SEPTIC TANK INSTALLATION
1. A new 1,2,5.0-gallon septic tank must be procured from an approved
source and installed at the location shown.
A septic tank is to be constructed by a certified septic tank
manufacturer. Construction shall include two 4" cleanouts for pumping
access.
3. Th.e... septic tank shall be sufficiently bedded to prevent settling or
shlfbng of the tank.
4. All standpipes on the septic tank shall extend a minimum of 12 inches
above finalgrade. . -
5. Tanks In'stalled without 4' of cover shall have a minimum .of 2" of direct
burial insulation.
6. A foundation cleanout shall be installed one to four feet from the
building foundation. Two cleanouts are required between the tank and
Lot 1, Block 4, Knik View Estates Subdivision
· IVlarch 5, 2002
Page 2 of 3
7. Final grading over the tank shall be such that a positive slope exists
away from the septic tank.
DRAINFIELD CONSTRUCTION:
1. The drainfield shall be constructed to the dimensions shown on the
design. The bottom of the trench shall be within 2" of level.
2. Distribution piping must be placed level with perforations down atop a
level bed of drainfield rock. Rock should then be placed over the pipe
to provide a minimum of 2" of cover.
3. A silt barrier or geotextile fabric must be placed between the drainfield
rock and the natural soil backfill.
4. Monitor tubes must be 4" in diameter and installed at the locations
shown on the design. The portion below ground must be perforated.
Contractor shall vedfy the septic tank and drainfield are a minimum
100' away from any pdvate water wells in the area, 150' from a Class
"C" Well or 200' from any community well.
Direct bury insulation must be placed over the distribution system if
less than 3' of backfill depth is available. Finish grade over the trench
must be mounded to prevent settlement or depressions.
7. Grade area surrounding the absorption trench to drain away.
A minimum 2' of accepting soil is required below the drainfield rock for
a 5' wide trench. Contractor shall redly this condition prior to
placement of the reck. All pockets of unacceptable materials must be
removed and replaced.
MATERIAL SPECIFICATIONS:
1. Septic tanks must be constructed by a municipally approved septic
tank manufacturer.
2. The following pipe materials are appreved for use in septic system
installations in the Municipality of Anchorage:
Cast Iren (perforated and solid), ASTM D3034 or P.V.C. (perforated
and solid), ASTM F810 or H.D.P.E. (perforated, but not sol!d)'and
ASTM D2662 or A.B.S. (perforated and solid).
Insulation shall be at least 2" thick extruded direct burial polystyrene
(Dow Chemical Co. Styrofoam HI or equal). ' '. ' '
Septic tank inlets and outlets shall be fitted with watertight couPlings
(Caulder, Femco, or equal). .:...,' ~." '
· .. Lot 1, Block 4, Knik View Estates Subdivision
-- .~ ~i~arch 5, 2002
Page 3 of 3
5. A permeable geotextile fabric (Typar, Mirafi or equal) must be installed
between the final drain rock layer and the native soil layer.
6. All drain rock shall be .5" to 2.5" in diameter with less than 3% passing
the #200 sieve.
INSPECTIONS:
Municipal Ordinance requires a minimum of two inspections. These
inspections must be conducted under the supervision of a professional
engineer registered in the State of Alaska. The first inspection must be
conducted after the excavation of trenches, beds or pits and before the
installation of any gravel. A septic tank may be set in place, but may not
be bacldilled.
The second inspection must be conducted after the placement of the
geotextile fabdc, gravel, distribution piping, standpipes, cleanouts and
insulation. No backfill should be in place at the time of inspection.
Contractor shall provide a copy of all field survey layout and construction
notes for use in preparing the certified as-built of the completed system.
Parcel I.D. 51.043-32
2. NUMBER OF BEDROOMS:
Municipality of Anchorage
Development Services Department
Building Safety Division
On-Site Water and Wastewater Program
4700 South Bragaw St.
P.O. Box 196650 Ancho, age, AK 9951~6650
www.ci.anchorage.ak..us
(907) 343-7904
CERTIFICATE OF HEALTH AUTHORITY APPROVAL
FOR A SINGLE FAMILY DWELLING
Expiration Date:
GENERAL INFORMATION
Complete legal description
Location (site address or directions) Judd Drive at Rankin Drive
Current Properly owner(s) MM&M Contractinq, Inc.
Mailing address P.O. Box 670495 Chuniak. AK 99567
Lending agency
Mailing address
Real Estate Agent
Mailing Address
Unless otherwise requested, HAA will be held by DSD for pickup.
Four
3. TYPE OF WATER SUPPLY:
Individual Well
Individual Water Storage
Community Class _A Well
Public Water System
Lot 1. Block 4. Knik View Estates Subdivision
Day phone 688-1236
Day phone
Day phone
TYPE OF WASTEWATER DISPOSAL:
[] Individual On-site
[] Individual Holding tank
[] Community On-site
[] Public Sewer
The Municipality of Anchorage Development Services Department (DSD) Issues Certificates of Health Authority
Approval (HAA) based only upon the representations given in paragraph 5 by an independent professional civil
engineer registered in the State of Alaska. Certificates of Health Authority Approval are required for the transfer of
title (except between spouses) for properties served by a single family on-site wastewater disposal and/or water
supply system. DSD also issues HAAs upon request to homeowners. Certificates of Health Authority Approval are
valid for 90 days from the date of issue for properties served by a private or Class C well and may be reissued with
new water sample results less than 30 days old. (Certificates may be reissued for a period of up to one year with
valid water samples.) Certificates are valid for one year for proper[les served by Class A or B wells or a public
water system. The Municipality of Anchorage is not responsible for errors or omissions in the professional
engineer's work.
4. STATEMENT OF INSPECTION BY ENGINEER
As certified by my seal affixed hereto and as of tne validation date shown below, I verify that my investigation,
based on procedures outlined in the Health Authority Approval Guidelines for this application, shows that the
on-site water supply and/or wastev;ater disposal system is(are) safe, functional and adequate for the number of
bedrooms and type of structure indicated herein. I further verify that based on the information obtained from the
Municipality of Anchorag~ files and from my investigation and inspection, the on-site water supply and/or
wastewater disposal system is(are) in compliance with all applicable Municipal and State codes, ordinances,
and regulations in effect at the lime of installation.
Name of Firm Anderson Enaineefinq
Phone 522-T/73
Address P.O, Box 240773 Anchorage, AK 99524
Engineer's Printed Name Michael E. Anderson, P.E.
DSD SIGNATURE
t// Approved for
Disapproved.
bedrooms.
Date 7122./2002
...~:..- Or A/-i',.
~^'. CE-,~23t .' .:~
Conditional approval for
bedrooms, with the following stipulations:
Additional Comments
"
_
~. ON-~II '- . C~
~3. WATER AND .
~ : WASTEWAI'ER :
Attachments:
HAA Checklist
Septic System Advisory
Well Flow Advisory
By:
(Rev. 12~00)
X
Maintenance Agreements
Supplemental Engineer's Report
Other
Original Certificate Date:
Municipality of Anchorage
Development Services Department
Building Safety Division
On-Site Water & Wastewater Program
43'00 South Bragaw St.
P.O. Box 196650 Anchorage, AK 99519-~650
www.ci.ancberage.ak.us
(~07) 343-7e04
HEALTH AUTHORITY APPROVAL CHECKLIST
Legal Description: LotLBIock4, KNkVlawEstates
A. WELL DATA
WeU type A_
Date completed __
Total depth ft.
ff A, B. or C pmvida FWVSID #
FROM WELL LOG
g.p.m.
Nitrate mg./I.
C~lacted by:
Date of test
Static water level
Well production
WATER SAMPLE RESULTS:
Date of sample: ·
Bo SEPTIC/HOLDING TANK DATA
Tank Type/Matadel 8el~./Steel
Tank size 1~50 gal,
Foundation deanout (Y/N) Y
Date of pumping
C. ABSORIrrION FIELD DATA
Number of Compartments
Depression over tank (Y/N)
Pumper New Cons=ucflon
Parcel ID: 051-043-32
wel~ Log (Y/N)
Wires properly protected (Y/N)
Casing height (above ground)
AT INSPECTION
g.p.m,
Date installed 3rLq)~2002 Soil rating (g.p,d./ff~ or ~rodrm) t.2 6PD/~F
Length 62
Total depth ~ fl.
Date of adequacy test
P
Date installed 3/30/2002
Cteanouts (Y/N) Y
High water elarm (Y/N) N
colonlas/lO0 mi.
System type 5' Wide Shallow Trench
lt. Width 5 fl. Gravel below pipe 4 ft.
Eft, absorption area 520 .~ Monitoring tube Y Dapre$_ _$1on over field .N_
Results (Pass/Fell)
Fluid depth in absorption field before test in. Water added gal.
Elapsed Time: min. Final fluid depth in. Absorption rate >=
Any rejuvenation lmatment (past 12 mo.) (Y/N & type) N Eyes, give date
New depth in.
g.p.d.
D. LIFT STATION
Date installed
'Pump on" level at
Datum
E.
Size in gallons Manhole/Access (Y/N)
in. 'Pump off' level at __ in. High water alarm level at in.
Cycles tested Meets alarm & circuit requirements?
SEPARATION DISTANCES
SEPARATION DISTANCES FROM WELL ON LOT TO:
Septic tank/lift station on lot N/A
Absorption field on lot N/A
Public sewer main N/A
Sewer/septic service line
On adjacent lots N/A
On adjacent lots N/A
Public sewer manhele/cleanout N/A
Holding tank N/A
SEPARATION DISTANCES FROM SEPTICIHOLDING TANK ON LOT TO:
Building foundation >5' Property line >5'
Water main N/A Water sewice line >t0'
Wells on adjacent lots >200'
SEPARATION DISTANCE FROM ABSORPTION FIELD ON LOT TO:
Property line >t0' Building foundation >10'
Water Service line >10'
Cudain drain None N0ted
F. COMMENTS
Lo{ is sermd by AWWU water systsm,
G. ENGINEER'S CERTIFICATION
I certify that I have determined through field inspectk)ns and
re~4ew of Municipal mcorde that the above systems are in
conformance with MOA HAA guidelines in effect on this date.
Engineer's Printed Name Michael E. Anderson, P.E.
Date ~
HAAFee S "-~-7'~-. --
Receipt Number C~- ~)~ ~
(~. 12/0o)
Sudace water >10~
Wells on adjacent lots >200'
Absorption field >5'
Surface wat~ >100'
Water main >10'
Driveway. pa~ing/vehicle storage >25'